Positioners. 6/2 Product Overview

Size: px
Start display at page:

Download "Positioners. 6/2 Product Overview"

Transcription

1 /2 Product Overview SITRANS VP300 /3 Technical description Technical specifications /7 - all versions /8 - without Ex protection/with Ex ia/ib protection /9 Selection and Ordering data /11 Dimensional drawings /12 Technical description Technical specifications /17 - all versions /19 - with and without HART /21 - with PROFIBUS PA /23 - with FOUNDATION Fieldbus /25 - Option modules Selection and Ordering data /29 - /32 - Accessories /34 Dimensional drawings /35 Schematics /3 Mounting kit Sec. 9 Software SIMATIC PDM, for parametrize HART and PROFIBUS PA devices You can download all instructions, catalogs and certificates for free of charge at the following Internet address: Siemens FI

2 Product Overview Overview Application Description Catalog page Software for parameterization N Position control of pneumatic linear or part-turn actuators, also for intrinsically safe operation SITRANS VP300 Connection: 4 to 20 ma/hart Plain text available in a range of languages Local manual operation Non-contacting position detection OPOS Interface Robust enclosure Diagnostic function /3 SIMATIC PDM Partial stroke test (PST) Supports the replacement of devices with the equipment running Position control of pneumatic linear or part-turn actuators, also for intrinsically safe operation Universal device for positioning pneumatic actuators Connection: 4 to 20 ma /12 SIMATIC PDM HART; PROFIBUS PA or FOUNDATION Fieldbus Local manual operation Binary inputs and outputs Diagnostic function As above, but in flameproof enclosure for explosionproof application Blocking function Automatic startup As above, but in flameproof aluminum enclosure /12 SIMATIC PDM /2 Siemens FI

3 SITRANS VP300 Technical description Overview The SITRANS VP300 intelligent positioner is used for the continuous control of process valves with single or double-acting, pneumatic actuators. HART communication, an alarm module with digital inputs and outputs, and a position feedback module are available as options. The device can also be supplied with types of protection Ex ia and Ex n. As a further option the SITRANS VP300 is available as a SIL device. Benefits SIL The SITRANS VP300 positioner is characterized by the following features: OPOS Interface (mechanical and pneumatic interface according to VDI/VDE 3847) for particularly simple installation with two screws and and integral piping Mounting kits for conversion of existing actuators (e.g. according to IEC or VDI/VDE 3845) to OPOS Interface Non-contacting position detection with practice-proven and robust GMR (giant magnetoresistance) principle saves having to install levers and makes the device less sensitive to vibrations User interface on-site contains plain text, graphics and different languages that can be selected (English, German, Span- Device versions ish, French, Italian and Chinese). Parameterization and activation of functions (e.g. tight closing, characteristic curves, partial stroke test) either on the device or using SIMATIC PDM (on HART device) Can be used as standard in the temperature range from -40 C to +85 C (-40 F to +185 F) One device for linear and part-turn actuators, either singleacting or double-acting Design Extensive diagnostic functions (stiction, deadband, move Introduction lower endstop, etc.) included as standard in every device Partial stroke test for testing SIL 2 applications SIL 2 for safe venting High degree of protection IP Application Overview The intelligent electropneumatic positioner is used, for example, in the following industries: Chemical industry Oil and gas Energy production Food and beverage industry Pulp and paper Water, waste water Pharmaceutical industry Mining and aggregates The positioner is used for the continuous control of process valves with single or double-acting, pneumatic actuators. The positioner can be installed on a wide range of linear and partturn actuators. Setpoints and electrical power supply for the positioner are fed through a 4 to 20 ma setpoint signal. As an option, HART communication and an alarm module with digital inputs and outputs are also available. Also available as an option is a module for position feedback, which outputs the valve position using a 4 to 20 ma signal. Explosion-proof device versions In addition to a device version for non-hazardous applications, the device is also available as an intrinsically safe design with types of protection Ex ia and Ex n. As a further option the SITRANS VP300 is available as a SIL device. In that case, the following applies: Safe shutdown function with SIL 2. On request using digital input DI 3 or in the case of failure of the electrical or pneumatic supply, ventilation is carried with actuating pressure Y1. A connected single-acting actuator moves the valve into the safe final position. The SIL device is certified in order to test partial strokes in applications up to SIL 2. The result of this so-called partial stroke test is then reported with digital output DO 1 (fail-safe). Optionally, the result can also be reported through HART communication. The positioners can be supplied: For single and double-acting actuators For non-hazardous applications For use as an intrinsically safe device Ex ia or Ex n With HART communication through the 4 to 20 ma control pulse The electropneumatic positioner is made up of the following components: Enclosure and cover Display assembly with connecting terminals Control assembly Sensors for non-contacting position detection Pneumatic valve block Siemens FI /3

4 SITRANS VP300 Technical description The valve block is located in the enclosure. Both the pneumatic interface and the mechanical interface of the SITRANS VP300 are provided by the innovative OPOS Interface. Behind this name stands the directive VDI/VDE 3847, with additional functionality and greater customer benefit. The positioner is mounted on the front with only two screws and is ready for operation without any external piping. If the interface of the actuator does not correspond with the VDI/VDE 3847 directive, the positioner is mounted using the adapter block of the corresponding mounting kit. With the SITRANS VP300, position detection is carried out on a non-contacting basis using a magnet and sensors in the positioner. The magnet for position detection on a non-contacting basis is in the magnet holder. In the case of linear actuators, the magnet holder is attached to the drive spindle and moves up and down on the back of the positioner. In the case of part-turn actuators, the magnet holder is attached to the shaft butt and turns underneath the positioner. The valve position is detected by the robust GMR principle, which identifies the direction of the magnetic field lines. GMR stands for "giant magnetoresistance". Gauges for displaying pressure can be fastened to the adapter block as an accessory, and you can connect a safety solenoid valve. A shutdown tap for the compressed air connections, which is useful when replacing the device without having to shut down the equipment, can also be connected. The positioner regulates e.g. valves: With a linear actuator or an integrated linear actuator with an interface according to VDI/VDE The linear actuator with an interface according to VDU/VDE 3847 requires only a magnet holder for position detection and no additional mounting kit. With a part-turn actuator or an integrated part-turn actuator with an interface according to VDI/VDE The part-turn actuator with an interface according to VDU/VDE 3847 requires only a magnet holder for position detection and no additional mounting kit. Digital inputs In its standard form, the electropneumatic positioner has two digital inputs DI 1 and DI 3. Digital input DI 1 can be parameterized and performs e.g. the following tasks: Blocking the actuator Moving the actuator Digital input DI 3 is only used to move the actuator into a safety position. Option modules The device provides slots for option modules, which can be used for retrofitting the following functions or ordering them directly from the factory: Position feedback module Position feedback is provided as a 4 to 20 ma signal. Alarm module - 3 freely parameterizable digital outputs - 1 freely parameterizable digital input Design of a control valve Pneumatic linear actuator 2 Positioner 3 Process valve 4 Electrical connection Positioner, attached to linear actuator Pneumatic part-turn actuator 2 Positioner 3 Mounting block with integrated air duct Positioner, attached to part-turn actuator /4 Siemens FI

5 SITRANS VP300 Function The positioner is a field device with a microcontroller. It is used to adjust and control pneumatic actuators on an electropneumatic basis. The setpoint and actual value of the actuator position are electronically compared in a microcontroller. If the microcontroller detects a deviation, it uses a control algorithm to actuate the pneumatic block inside the positioner. Air is blown into the chamber or chambers of the pneumatic actuator, or removed in the opposite direction. The pneumatic block doses this air flow. The linear or part-turn movements are detected by non-contacting sensors. Local operation Using the four buttons you can parameterize and operate the positioner as well as switch between automatic and manual mode. The positioner s settings and feedback can be followed on the display. Actuator adjustments over the entire range are possible in manual mode. Commissioning Using the "Quick Start" menu, the electropneumatic positioner can be quickly adapted to the valve and adjusted by means of an automatic startup function. The microcontroller optimizes the control by determining the following data (among others) during the initialization process: Zero point Full-scale value Direction of action Positioning speed of shifting Dynamic positioning Monitoring functions The electropneumatic positioner has different monitoring functions. They detect changes to the actuator and valve and compare them with the defined limits. If a limit is exceeded, the display shows the corresponding diagnostic message. This information may be important for diagnosis of the actuator or valve. The following measuring data, some with adjustable limits, are determined and monitored: Travel integral Number of changes in direction Alarm counter Deadband Valve end limit position (e.g. for detection of valve seat wear or deposits) Operating hours (also according to temperature and travel ranges) as well as min./max. temperature Valve positioning time Technical description Status monitoring with 3-stage alarm concept The intelligent electropneumatic positioner is equipped with additional monitoring functions. The status indications derived from these monitoring functions signal active faults of the unit. The severity of these faults is graded using "traffic light signaling", symbolized by a wrench in the colors green, yellow and red (in SIMATIC PDM and Maintenance Station). Presentation in SIMATIC PDM and the Maintenance Station is as follows: Need for maintenance - indicated by a green wrench Urgent need for maintenance - indicated by a yellow wrench Imminent danger of unit failure - indicated by a red wrench This allows users to put early measures into action before a serious valve or actuator fault occurs which could result in a system shutdown. An alarm is signaled in good time. With suitable maintenance strategies in place the user can ensure plant availability. An alarm is triggered for example by the progressive sluggishness of a unit. This three-stage alarm hierarchy also allows early detection and signaling of static friction on a packing box, signs of wear on a valve plug or valve seat, and valve sedimentation or incrustation. The alarms are issued through the digital outputs of the positioner and through HART communication. Three digital outputs are available. HART communication supplies the following information about the unit: differentiation between the various alarms presentation of one position control circuit parameter in a trend graph Histogram in the form of a bar graph of all the control circuit s parameters. The graded maintenance requirements, complete with identification of the source of the fault, are also indicated in the device display. Siemens FI /5

6 SITRANS VP300 Technical description Mode of operation HART-coupler I w 7 Limitation Load control 9 DI 1 10 Digital input DI 1 Setpoint sensing HART modem GND 81 DI 3 Control pneumatic block 82 Microcontroller Display RAM Position displacement sensor Buttons DI 2 l Y 2 ROM Temperature sensing DI 2 DO 1 EEPROM Position feedback module (optional) EEPROM Alarm module (optional) DO 2 DO 3 SITRANS VP300 electropneumatic positioner, function diagram / Siemens FI

7 SITRANS VP300 Technical specifications Technical specifications SITRANS VP300 (all versions) General data Range of stroke (linear actuators) Angle of rotation (part-turn actuators) Controller unit 1) mm ( inch) mm ( inch) for selected actuators) Non-linearity < 1 % Repeatability < 1 % Hysteresis < 1 % Temperature influence effect < 0.5 %/10 K in the range of C ( F) Shock influence effect and vibration influence effect < 1 % (20 m/s 2 or 0.15 mm; Hz) Degree of protection IP to EN 0529 Material Enclosure DR3*0 (aluminum) EN 170: EN AC-AISI12(Fe) or EN AC-AISI10Mg(Fe) Vibration resistance Harmonic oscillations (sine-wave) according to EN /02/2008 Bumping (half-sine) to EN /03.95 Noise (digitally controlled) according to EN /04/ mm (0.14 inch), Hz 3 cycles/axis 100 m/s² (328 ft/s²), Hz, 3 cycles/axis 250 m/s² (820 ft/s²), ms, 1000 shocks/axis Hz; 1 (m/s²)²/hz (3.28 (ft/s²)²/hz) Hz; 0.3 (m/s²)²/hz (0.98 (ft/s²)²/hz) 1.15 kg (2.535 lb) Weight Climatic class According to EN Storage 1K3 Transport 2K4 Operation 2) 4K4, but C ( F) Certificates and approvals Classification according to pressure equipment directive (PED 97/23/EC) CE marking For gases of fluid group 1; complies with requirements of article 3, para. 3 You can find the appropriate directives and standards, including the relevant versions, in the EC Declaration of Conformity on the Internet Pneumatic data Auxiliary power (air supply) Compressed air and nitrogen Pressure bar ( psi) Air quality to ISO Solid particulate size and density Class 3 Pressure dew point Class 3 (min. 20 K below ambient temperature) Oil content Class 3 Unrestricted flow Inlet air valve (depressurize actuator) - 2 bar (29 psi) 7.5 Nm³/h (33 USgpm) - 4 bar (58 psi) 10. Nm³/h (4.7 USgpm) - bar (87 psi) 13 Nm³/h (57.2 USgpm) Outlet air valve(depressurize actuator) - 2 bar (29 psi) 14.4 Nm³/h (3.4 USgpm) - 4 bar (58 psi) 20.4 Nm³/h (89.8 USgpm) - bar (87 psi) 25 Nm³/h (110.1 USgpm) Auxiliary power consumption in the < 9, Nm³/h (0.2 USgpm) controlled state Device versions single-acting and double-acting Gauge made of steel Degree of protection IP44 Vibration resistance According to EN Communication HART Version Languages Menu languages English, German, Spanish, French, Italian, Chinese 1) All percentage values refer to a 20 mm stroke range or 90 angle of rotation, measured as per IEC ) At -20 C (-4 F) the display refresh rate of the indicator is limited. At > 70 C, the contrast for the display is limited. Siemens FI /7

8 SITRANS VP300 Technical specifications SITRANS VP300 - without Ex protection and with Ex ia/ib protection SITRANS VP300 without Ex protection with Ex ia/ib protection Explosion protection as per ATEX Without Ex ia/ib II 2 G Ex ia IIC T/T4 Mounting location Zone 1 Permissible ambient temperature for operation C( F) T4: C ( F) T: C ( F) Electrical specifications Setpoint input I w 2-wire connection (terminals /7) Rated signal range mA Current to maintain the auxiliary power supply 3.8 ma Required load voltage U B (load resistance at 20 ma) without HART (DR30*) max..5 V (325 Ω) 7.5 V (375 Ω) with HART (DR31*) 7.5 V (375 Ω) 8.5 V (420 Ω) Static destruction limit 30 V - (internal current load approx. +50 ma) -150 ma (with poled connection) Effective internal capacitance C i - 33 nf Effective internal inductance L i mh For connecting to circuits with the following peak values - Intrinsically safe U i = 30 V DC I i = 100 ma P i = 1 W Digital input DI 1 (terminal 9/10; galvanically connected with basic device) Suitable only for floating contact; max. contact load 0.1 ma with 3 V Connectable external capacitance C O - 1 μf Connectable external inductance L O - 1mH For connecting to circuits with the following peak values - Intrinsically safe U o = 5 V DC I o = 0.5 ma P o = 2.5 mw Digital input DI 3 (terminal 81/82); can be activated for safety shutdown with switch Input resistance > 20 kω Switch in "enable" position Signal state "0" = Safety shutdown V or unused Signal state "1" = normal operation V Switch in "disable" position Normal control mode; safety shutdown V or unused inactive Internal capacitance C i - Negligibly small Internal inductance L i - Negligibly small For connecting to circuits with the following peak values Ports electrical - Intrinsically safe U i = 30 V DC I i = 100 ma P i = 1 W Screw terminal 2.5 AWG28-12 Cable feed (M20x1.5 or ½-14 NPT) or plug M12 pneumatic OPOS Interface (VDI/VDE 3847) /8 Siemens FI

9 SITRANS VP300 Selection and Ordering data Order No. SITRANS VP300 electropneumatic D) D R A 7 0 positioner Version 2-wire without HART 0 with HART 1 Enclosure design Aluminum, painted 0 Actuator type single-acting 1 double-acting 1) 2 Explosion protection Without N N ATEX/IECEx E Ex ia, Zone 1 Ex ic, Zone 2 Ex iad, Zone 21 FM/CSA 1) IS, Class I, Zone 1, IIC IS, Class I, Div 1, ABCD NI, Class I, Zone 2, IIC NI, Class I, Div 2, ABCD IS, Class II, III, Div 1, EFG ATEX/IECEx 1) G Ex n, Zone 2 Ex td, Zone 22 FM/CSA 1) NI, Class I, Zone 2, IIC NI, Class I, Div 2, ABCD NI, Class II, III, Div 2, EFG Approvals for explosion protection Without N ATEX, IECEx, FM, CSA, GOST, S NEPSI, INMETRO 1) ATEX, IECEx A FM 1) B CSA 1) C GOST 1) D NEPSI 1) E INMETRO 1) F Electric connection Cable gland M20x1.5 1 Thread adapter ½ NPT 2 M12 plug 3 Limit monitor Without 0 Alarm module, electronic 1) 1 Option modules Without 0 Position feedback module 1 4 to 20 ma 1) OEM version None A D) Subject to export regulations AL: N, ECCN: EAR99H. Technical specifications Selection and Ordering data Order No. SITRANS VP300 electropneumatic D) D R A 7 0 positioner Further designs Order code Add "-Z" to Order No. and specify order code. TAG plate made of stainless steel, A01 3-line Text line 1: Plain text from Y17 Text line 2: Plain text from Y15 Text line 3: Plain text from Y1 Version with stainless steel sound A40 absorbers 1) Certificates Final check C11 SIL, only for single-acting device C20 (you must order a certificate to receive a SIL-certified device) 1) Measuring point description Y15 Max. 1 characters, specify in plain text Y15:... Measuring point text Y1 Max. 24 characters, specify in plain text Y1:... Measuring point number (TAG No.) Y17 Max. 8 characters, specify in plain text Y17:... 1) In preparation Note: To operate the SITRANS VP300 you need a matching magnet holder (contains one magnet). You can order this magnet holder as part of the mounting kit or separately as an accessory. Siemens FI /9

10 SITRANS VP300 Technical specifications Selection and Ordering data SITRANS VP300 electropneumatic positioner, mounting kits Order No. Material mounting kit Aluminum 1 D) D R A 7 Actuator type Single-acting 1 Double-acting 1) 2 Type mounting kit Standard linear actuators IEC (NAMUR), up to 0 mm (2.3 inch) IEC (NAMUR), up to 150 mm (5.9 inch) 1) Standard part-turn actuators For existing mounting consoles B A according to VDI/VDE 3845 For actuators according to VDI/VDE B B 3845 with hole pattern 30 x 80 x 20 mm (1.18 x 3.15 x 0.79 inch) For actuators according to VDI/VDE B C 3845 with hole pattern 30 x 80 x 30 mm (1.18 x 3.15 x 0.79 inch) or 30 x 130 x 30 mm (1.18 x 5.12 x 0.79 inch) 1) For actuators according to VDI/VDE B D 3845 with hole pattern 30 x 130 x 50 mm (1.18 x 5.12 x 1.97 inch) 1) Integrated manufacturer-specific interfaces for linear actuators Flowserve FlowAct 127/252/502/700 1) C A ARCA ARCAPAQ type 812 1) C B RTK ST 115/135/10 (pneumatic connections only G ¼) C C1 0 Fisher GX 1) C D Integrated manufacturer-specific interfaces for part-turn actuators Neles series EC and EJ 05 - D A 14 1) Samson linear actuators Type 3277 for integrated mounting E A 0 Type for integrated mounting E B 0 Other types according to IEC , up to 0 mm (2.3 inch) 1) E C Other types according to IEC , up to 150 mm (5.9 inch) 1) E D Other linear actuators Adapter for mech. interface F A, up to 0 mm (2.3 inch) Fisher type series 5 and 7 F B 30/34/40/45/4/50/0, up to 0 mm (2.3 inch) 1) Fisher type series 5 and 7 F C 70/7/80/87/100, up to 150 mm (5.9 inch) 1) RTK ST 141, up to 0 mm (2.3 inch) F D1 (pneumatic connections only G ¼) RTK ST 141, up to 150 mm (5.9 inch) F E1 (pneumatic connections only G ¼ 1) ) Other part-turn actuators Masoneilan Camflex II G A Neles BC/BJ ) G B A A A B Selection and Ordering data Order No. SITRANS VP300 electropneumatic D) D R A7 positioner, mounting kits Connections, pneumatic G ¼ 1 ¼-18 NPT 2 Shutoff valve 1) for replacement during operation Without 0 With 1 Interface for solenoid valve according to VDI/VDE 3845 Without 0 With (pneumatic connections only 1 1 G¼) Gauge Without A Gauge made of steel, scaled in B bar/mpa/psi Magnet holder (contains magnet for position detection on a non-contacting basis) Without 0 With 1 Further designs Order code Measuring point number (TAG No.) Y17 Max. 8 characters, specify in plain text Y17:... 1) Available soon D) Subject to export regulations AL:N, ECCN: EAR99H. /10 Siemens FI

11 SITRANS VP300 Dimensional drawings Selection and Ordering data Dimensional drawings Magnet holder (contains magnet for position detection on a non-contacting basis) Order No. 1 (.54) 10 (.30) Linear actuators up to 0 mm (2.3 inch) DR003-1P Part-turn actuators and linear actuators > 0 mm (2.3 inch) Single-acting gauge Block made of aluminum, connection G¼, gauge made of steel, scaled in bar/mpa/psi, thread G1/8 Block made of aluminum, connection ¼-18 NPT, gauge made of steel, scaled in bar/mpa/psi, thread 1/8-27 NPT double-acting gauge 1) DR003-2P DR003-1MG1 DR003-1MN1 (0.24) s 20 (0.78) 30 (1.18) 20 (0.78) 25 M4 107 (0.98) 30 (4.21) (1.18) 89 (3.50) 10 (0.39) 9 (0.35) M 3 (1.41) 80 (3.15) 90 (3.54) 33 (1.30) Block made of aluminum, connection G¼, gauge made of steel, scaled in bar/mpa/psi, thread G1/8 DR003-2MG1 Linear actuator, dimensions in mm (inch) Block made of aluminum, connection ¼-18 NPT, gauge made of steel, scaled in bar/mpa/psi, thread 1/8-27 NPT DR003-2MN1 1 (.54) 10 (.30) Shut-off module (single-acting and double-acting) 1) Module made of aluminum Module for solenoid valve interface according to VDI/VDE 3845 Aluminium module, connection G¼ (not for integrated actuators) Position feedback module (4 to 20 ma) 1) Non explosion-proof Explosion protection Alarm module, electronic 1) Non explosion-proof DR003-8L DR003-8SG1 DR003-8J DR003-J DR003-8A 10,5 (0.41) M s 89 (3.50) (0.98) (0.39) (0.78) 25 (0.98) 95 (3.74) Part-turn actuator, dimensions in mm (inch) 9 (0.35) M 3 (1.41) 80 (3.15) 90 (3.54) 33 (1.30) Explosion protection Cover plate for solenoid valve interface DR003-A 32 (1.2) Aluminum DR003-8SC1 Documentation Operating instructions in German Operating instructions in English 1) Available soon A5E A5E01258 Y2 PZ Y1 3 (1.42) 2,5 (1.04) 95 (3.74) Rear side, dimensions in mm (inch) Siemens FI /11

12 Technical description Overview Electropneumatic positioner in the Makrolon enclosure Ex d electropneumatic positioner in flameproof aluminium enclosure (Ex d) in stainless steel enclosure The electropneumatic positioner is used to control the final control element of pneumatic linear or part-turn actuators. The electropneumatic positioner moves the actuator to a valve position corresponding to the setpoint. Additional function inputs can be used to block the valve or to set a safety position. A binary input is present as standard in the basic device for this purpose. Benefits positioners offer decisive advantages: Simple installation and automatic commissioning (self-adjustment of zero and span) Simple operation with - Local operation (manual operation) and configuration of the device using three buttons and a user-friendly two-line display - Parameterization via SIMATIC PDM Very high-quality control thanks to an online adaptation procedure Negligible air consumption in stationary operation "Tight shut-off" function (ensures maximum positioning pressure on the valve seat) Numerous functions can be activated by simple configuring (e.g. characteristic curves and limits) Extensive diagnostic functions for valve and actuator Only one device version for linear and part-turn actuators Few moving parts, hence insensitive to vibrations External non-contacting position sensor as option for extreme ambient conditions "Intelligent solenoid valve": Partial Stroke Test and solenoid valve function in a single device Partial Stroke Test e.g. for safety valves Can also be operated with natural gas SIL (Safety Integrity Level) 2 Application The positioner is used, for example, in the following industries: Chemical/petrochemical Power stations Paper and glass Water, waste water Food and pharmaceuticals Offshore plants The positioner is available: For single-acting actuators: In Makrolon, stainless steel or aluminum enclosure, as well as flameproof aluminum enclosure (Ex d) For double-acting actuators: In Makrolon enclosure, stainless steel enclosure and flameproof aluminum enclosure (Ex d) For non-hazardous applications For hazardous applications in the versions - Type of protection intrinsic safety "Ex i" - Type of protection flameproof enclosure "Ex d" in flameproof aluminium enclosure - Type of protection non-sparking "Ex na", energy-limited "Ex nl", dust protection via enclosure "Ex td" and in the versions: With 0/ ma control with/without communication through HART signal With PROFIBUS PA communication interface With Foundation Fieldbus (FF) communications interface. /12 Siemens FI

13 Explosion-proof versions The device is available in the following versions for use in atmospheres subject to explosion hazards: Flameproof design for use in zone 1 and class I, division 1 Intrisically safe design for use in zone 1 and class I, division 1 Non-sparking and energy-limited design for use in zone 2 and class I, division 2 Dust-protected design for use in zone 22 Dust-protected design for use in class II, division 1 and 2 and class III Stainless steel enclosure for extreme ambient conditions The is available in a stainless steel enclosure (with no window in the cover) for use in particularly aggressive environments (e.g. offshore operation, chlorine plants etc.). The device functions are the same as for the basic version. Design The positioner is a digital field device with a highlyintegrated microcontroller. The positioner consists of the following components: Enclosure and cover PCB with corresponding electronics with or without communication through HART or with electronics for communication in accordance with - PROFIBUS PA specification, IEC ; bus-supplied device, or - Foundation Fieldbus (FF) specification, IEC , bus-supplied device Position detection system Terminal housing with screw terminals Pneumatic valve manifold with piezoelectric valve precontrol. The valve manifold is located in the housing, the pneumatic connections for the inlet air and the positioning pressure on the righthand side. A pressure gauge block and/or a safety solenoid valve can be connected there as options. The positioner is fitted to the linear or part-turn actuator using an appropriate mounting kit. The circuit board container in the casing provides slots for separately ordered boards with the following functions: I y module: Position feedback as a two-wire signal 4 to 20 ma Alarm module (3 outputs, 1 input): Signaling of two limits of the travel or angle by binary signals. The two limits can be set independently as maximum or minimum values. Output of an alarm if the setpoint position of the final control element is not reached in automatic mode or if a device fault occurs. Second binary input for alarm signals of for triggering safety reactions, e.g. blocking function or safety position. Limit signaling through slot-type initiators (SIA module) Two limits can be signaled redundantly as NAMUR signals (EN ) by slot-type initiators. An alarm output is also integrated in the module (see Alarm module). Technical description Limit value signal via mechanical contacts (limit value contact module) Two limits can be signaled redundantly by switching contacts. An alarm output is also integrated in the module (see Alarm module). Valid for all modules described above: All signals are electrically isolated from one another and from the basic unit. The outputs indicate self-signaling faults. The modules are easy to retrofit. Separate mounting of positioner detection system and controller unit The position detection system and controller unit can be connected separately for all casing versions of the (except flameproof design). Measurement of the travel or angle is carried out directly on the actuator. The controller unit can then be fitted a certain distance away, e.g. on a mounting pipe or similar, and is connected to the position detection system by an electric cable and to the actuator by one or two pneumatic lines. Such a split design is frequently advantageous if the ambient conditions at the fitting exceed the specified values for the positioner (e.g. strong vibrations). The following can be used for measuring the travel or angle: NCS sensor External position detection system C73451-A430-D78 A commercially available potentiometer (10 kω resistance), e.g. for higher application temperatures or customer-specific applications The use of potentiometers is recommended for very small linear actuators with a short valve travel since, on the one hand, the space required by the potentiometer is very small and, on the other, the transmission characteristic is optimum for a small travel Pneumatic connection 2 Pneumatic connection for double-action actuators 3 Travel detection system (10 kω potentiometer or NCS) 4 Electric cable 5 Retrofitted EMC filter module (in device) Separate mounting of positioner detection system and controller unit Non-contacting position sensor (NCS) 4 3 Contact and non-contacting position sensor (NCS) for part-turn actuator (left) and for linear actuator 14 mm (0.55 inch) (right) Siemens FI /13

14 Technical description NCS for travels >14 mm (0.55 inch) The NCS sensor consists of a non-contacting position sensor. All coupling elements are omitted such as coupling wheel and driver pin with part-turn actuators or lever and pick-up bracket with linear actuators for up to 14 mm travel. This results in: Even greater resistance to vibration and shock No wear of sensor Problem-free mounting on very small actuators Negligible hysteresis with very small travels. The sensor does not require an additional power supply, i.e. (not for Ex d version) can be operated in a 2-wire system. The NCS (Non Contacting Position Sensor) consists of a potted sensor housing which must be mounted permanently and a magnet which is mounted on the spindle of linear actuators or on the shaft butt of part-turn actuators. For the version for travels >14 mm (0.55 inch), the magnet and the NCS are premounted on a stainless steel frame and offer the same interface mechanically as the positioner itself, i.e. they can be mounted using the standard mounting kits DR4004-8V, -8VK and -8VL. The installation of a EMC filter module in the positioner (controller unit) is necessary in order to ensure a connection level with EMC according to EC Declaration of Conformity when using external sensors (see Selection and ordering data for "EMC filter module"). Function The electropneumatic positioner works in a completely different way to normal positioners. Mode of operation Comparison of the setpoint and the actual value takes place electronically in a microcontroller. If the microcontroller detects a deviation, it uses a 5-way switch procedure to control the piezoelectric valves, which regulates the flow of air into and from the chambers of the pneumatic actuator or blows it in the opposite direction. The microcontroller then outputs an electric control command to the piezoelectric valve in accordance with the size and direction of the deviation (deviation between setpoint and actual values). The piezoelectric valve converts the command into a pneumatic positional increment. The positioner outputs a continuous signal in the area where there is a large system deviation (high-speed zone); in areas of moderate system deviation (slow-speed zone) it outputs a sequence of pulses. No positioning signals are output in the case of a small system deviation (adaptive or variable deadband). The linear or rotary motion of the actuator is detected by the mounting kit and transferred to a high-quality potentiometer over a shaft and a non-floating gear transmission. The angular error of the pick-up in cases where the assembly is mounted on a linear actuator is corrected automatically. When connected in a 2-wire system, the draws its power exclusively from the 4 to 20 ma setpoint signal. The electric power is also connected through the 2-wire bus signal with PROFIBUS operation ( PA). The same applies for the FOUNDATION Fieldbus version. Pneumatic valve manifold with piezoelectric valve precontrol The piezoelectric valve can release very short control pulses. This helps achieve a high positioning accuracy. The pilot element is a piezoelectric bending converter which switches the pneumatic main controller unit. The valve manifold is characterized by an extremely long service life. Local operation Local operation is performed using the built-in display and the three buttons. Switching between the operating levels Automatic, Manual, Configuring and Diagnosis is possible at the press of a button. In manual mode the drive can be adjusted over the entire range without interrupting the circuit. Operation and monitoring with the SIMATIC PDM configuration software The configuration software SIMATIC PDM permits simple operation, monitoring, configuration and parameterization of the device. The diagnostic information available can be read via SIMATIC PDM from the device. Communication is carried out via the HART protocol or PROFIBUS PA. For the HART protocol, the device can be accessed both via a HART modem and via a HART-compatible input/output module (remote IO). The corresponding device description files, such as GSD and (Enhanced) EDD are available for both types of communication. In addition, the SITRANS DTM provides software based on tried and tested EDD technology that can be used to parameterize field devices via a DTM (Device Type Manager) using an FDT frame application (e.g. PACTware). SITRANS DTM and the necessary device-specific enhanced EDD are available for download free of charge. The software provides the relevant communication interfaces for HART and PROFIBUS. Automatic commissioning With a simple configuration menu the can be quickly adapted to the fitting and adjusted by means of an automatic startup function. During initialization, the microcontroller determines the zero point, full-scale value, the direction of action and the positioning speed of the fitting. From this data it establishes the minimum pulse time and the deadband, thus optimizing the control. Low air consumption A hallmark of the is its own extremely low consumption of air. Normal air losses on conventional positioners are very costly. Thanks to the use of modern piezoelectric technology, the consumes air only when it is needed, which means that it pays for itself within a very short time. /14 Siemens FI

15 Comprehensive monitoring functions The has various monitoring functions with which changes on the actuator and valve can be detected and signaled if applicable when a selectable limit has been exceeded. This information may be important for diagnosis of the actuator or valve. The measuring data to be determined and monitored, some of whose limits can be adjusted, include: Travel integral Number of changes in direction Alarm counter Self-adjusting deadband Valve end limit position (e.g. for detection of valve seat wear or deposits) Operating hours (also according to temperature and travel ranges) as well as min./max. temperature Operating cycles of piezoelectric valves Valve positioning time Actuator leakages Status monitoring with 3-stage alarm concept The intelligent electropneumatic positioner is equipped with additional monitoring functions. The status indications derived from these monitoring functions signal active faults of the unit. The severity of these faults are graded using "traffic light signaling", symbolized by a wrench in the colors green, yellow and red (in SIMATIC PDM and Maintenance Station): Need for maintenance (green wrench) Urgent need for maintenance (yellow wrench) Imminent danger of unit failure or general failure (red wrench) This allows users to put early measures into action before a serious valve or actuator fault occurs which could result in a system shutdown. The fact that a fault indication is signaled, such as the onset of a diaphragm break in the actuator or the progressive sluggishness of a unit, enables the user to ensure system reliability at any time by means of suitable maintenance strategies. This three-stage alarm hierarchy also allows early detection and signaling of other faults, such as the static friction of a packing box, the wearing of a valve plug/seating, or precipitations or incrustations on the fittings. These fault indications can be output either line-conducted over the alarm outputs (see above) of the positioner (max. 3), or via communication over the HART or field bus interfaces. In this case, the HART, PROFIBUS and FF versions of permit a differentiation of the various fault indications, as well as a trend representation and histogram function of all key process variables with regard to the fittings. The device display also displays the graded maintenance requirements, complete with identification of the source of the fault. Functional safety acc. to SIL 2 The positioners are also suitable for the control of fittings, which meet the special requirements of the functional safety up to SIL 2 to IEC 1508 or IEC This is a single-acting, venting positioner with an input of 4 to 20 ma, PROFIBUS PA and FOUNDATION Fieldbus (FF) for mounting on pneumatic actuators with spring return. The positioner vents the valve actuator on demand/in the event of a fault and puts the valve in the preset safety position. This positioner meets the following requirements: Functional safety up to SIL 2 conforming to IEC 1508 or IEC for safe venting Explosion protection for the versions DR5...-.E... Electromagnetic compatibility to EN 132/A1, Appendix A.1 Technical description SIPART PS 2 as "intelligent solenoid valve Open / Close valves, safety fittings in particular, are generally pneumatically controlled over a solenoid valve. If you use instead of this type of solenoid valve, the positioner performs two tasks in a single device (without extra wiring) Firstly, it switches the fitting off on demand by venting the actuator (functional safety acc. to SIL 2 (see above) Secondly, it can perform a Partial Stroke Test at regular intervals (1-35 days), which prevents the blocking of the fitting, e.g. due to corrosion or furring. As in this case is constantly working in normal operation (e.g. 99 % position), it also acts as a permanent test function for the pneumatic output circuit, which is not usually possible when using a solenoid valve. Solenoid valves on control valves can also not normally be tested during operation. They are therefore not necessary when using SIPART PS 2 with a 4-wire connection system as the venting is carried out on demand by. This means that on control valves, both the control function and the shut-off function can be carried out by a single device. Configuring In configuring mode, the positioner can be configured to requirements and include the following settings: Input current range 0 to 20 ma or 4 to 20 ma Rising or falling characteristic curve at the setpoint input Positioning speed limit (setpoint ramp) Split-range operation; adjustable start-of-scale and full-scale values Response threshold (deadband); self-adjusting or fixed Direction of action; rising or falling output pressure with rising setpoint Limits (start-of-scale and full-scale values) of positioning range Limits (alarms) of the final control element position; minimum and maximum values Automatic "tight shut-off" (with adjustable response threshold) The travel can be corrected in accordance with the valve characteristic curve. Function of binary inputs Function of alarm output etc. Configuration of the various versions is largely identical. Siemens FI /15

16 Technical description 1 BE1 2 HART y 3 Inlet air + + y p Z I W+ +24 V +5 V Exhaust I W y 0 + W A D A D Exhaust Microcontroller p 1 p 1 p 2 p 2 x 0 W x U U I 5 4 BE2 A1 A2 I I p 2 A1 A2 p 1 Travel p 1 Travel Motherboard with microcontroller and input circuit Control panel with display and pushbuttons Piezoelectric valve unit, always present Valve unit, present as accessory in double-action positioner Iy module for controller Alarm module for 3 alarm outputs and one binay input SIA module (slot initiator alarm module, fig.) or limit value contact module Spring loaded pneumatic actuator (single-action) Springless pneumatic actuator (double-action) Note: Alarm module () and SIA module (7) can only be inserted as alternatives., electropneumatic positioner, function diagram /1 Siemens FI

17 Technical specifications Technical specifications (all versions) Rated conditions Permissible ambient temperature for operation Degree of protection 1) Mounting position Vibration resistance Harmonic oscillations (sine-wave) according to EN /05.9 Bumping (half-sine) according to EN /03.95 Noise (digitally controlled) according to EN /08.95 Recommended continuous duty range of the complete fitting See Technical specifications on page /20 IP according to EN 0529/NEMA 4X Any; pneumatic connections and exhaust opening not facing up in wet environment 3.5 mm (0.14"), Hz, 3 cycles/axis 98.1 m/s² ( ft/s²), Hz, 3 cycles/axis 150 m/s² (492 ft/s²), ms, 1000 shocks/axis Hz; 1 (m/s²)²/hz (3.28 (ft/s²)²/hz) Hz; 0.3 (m/s²)²/hz (0.98 (ft/s²)²/hz) 4 hours/axis 30 m/s² (98.4 ft/s²) without resonance sharpness Climatic class According to EN Storage 2) 1K5, but C (1K5, but F) Transport 2) 2K4, but C (2K4, but F) Operation 3) 4K3, but C (4K3, but F) 4) Pneumatic data Auxiliary power (air supply) Compressed air, nitrogen or cleaned natural gas Pressure bar ( psi): Air quality to ISO Solid particulate size and density Class 2 Pressure dew point Class 2 (min. 20 K (3 F) below ambient temperature) Oil content Class 2 Unrestricted flow (DIN 1945) Inlet air valve (ventilate actuator) 5) - 2 bar (29 psi) 4.1 Nm³/h (18.1 USgpm) - 4 bar (58 psi) 7.1 Nm³/h (31.3 USgpm) - bar (87 psi) 9.8 Nm³/h (43.1 USgpm) Outlet air valve (vent actuator) 5) - 2 bar (29 psi) 8.2 Nm³/h (3.1 USgpm) - 4 bar (58 psi) 13.7 Nm³/h (0.3 USgpm) - bar (87 psi) 19.2 Nm³/h (84.5 USgpm) Valve leakage < 10-4 Nm³/h (0.002 USgpm) Throttle ratio Adjustable up to : 1 Auxiliary power consumption in the < 3, 10-2 Nm³/h (0.158 USgpm) controlled state Design Mode of operation Range of stroke (linear actuators) Angle of rotation range (part-turn actuators) Mounting type On linear actuator On part-turn actuator mm ( ") (angle of positioner shaft ) Using mounting kit DR4004-8V and where necessary with an additional lever arm DR4004-8L on actuators according to IEC (NAMUR) with ribs, bars or flat face. Using mounting kit DR4004-8D on actuators with mounting plane according to VDI/VDE 3845 and IEC : The necessary mounting console is fitted on the actuator side. Material Enclosure - DR5**0-*** (Makrolon) Glass-fiber reinforced polycarbonate (PC) - DR5**1-*** (aluminium) GD AISi12 - DR5**2-*** (stainless steel) Austenitic stainless steel mat. No DR5**5-*** (aluminium, flameproof) GK AISi12 Pressure gauge block Aluminium AIMgSi, anodized Weight, basic device Glass-fiber reinforced enclosure Approx. 0.9 kg (1.98 lb) made from polycarbonate Aluminum enclosure Approx. 1.3 kg (2.8 lb) Stainless steel enclosure Approx. 3.9 kg (8. lb) Pressure-proof aluminum enclosure Approx. 5.2 kg (11.4 lb) Dimensions See dimensional drawings on page /34 Device versions In Makrolon enclosure Single-acting and double-acting In aluminum enclosure single-acting Im flameproof aluminium enclosure Single-acting and double-acting In stainless steel enclosure Single-acting and double-acting Gauge Degree of protection - Gauge made of plastic IP31 - Gauge made of steel IP44 - Gauge made of stainless steel IP54 31 Vibration resistance According to EN Controller Controller unit Five-point switch Self-adjusting Deadband - deba = Auto Self-adjusting or can be set as fixed value - deba = % Self-adjusting or can be set as fixed value Siemens FI /17

18 Technical specifications Analog-to-digital converter Scan time 10 ms Resolution 0,05 % Transmission error 0,2 % Temperature influence effect Cycle time 20 ma/hart device PA device FF device Certificates and approvals Classification according to Pressure Equipment Directive (PED 97/23/EC) CE marking EMC requirements 0.1 %/10 K ( 0.1 %/18 F) 20 ms 0 ms 0 ms (min. loop time) For gases of fluid group 1, complies with requirements of article 3, paragraph 3 (sound engineering practice SEP) The designated product matches the versions launched onto the market by us with the relevant European guidelines in accordance with the EC Declaration of Conformity. See EC Declaration of Conformity on the internet or included with the product. 1) Max. impact energy 1 Joule for enclosure with inspection window. 2) During commissioning at 0 C ( 32 F) make sure that the positioner is operated for long enough with dry pneumatic power supply. 3) At -10 C ( 14 F) the display refresh rate of the indicator is limited. 4) C ( F) for DR55..-0G..., DR5..-0G..., DR55..-0D... and DR5..-0D... 5) With Ex d version (DR5..5- ) values reduced by approx. 20 %. /18 Siemens FI

19 Technical specifications with and without HART Input 2-wire connection (terminals /8) Rated signal range Current to maintain the auxiliary power supply Required load voltage U B (corresponds to Ω at 20mA) Without HART (DR50..) without Ex protection with Ex d protection (flameproof enclosure) 4 20 ma 3. ma with Ex i explosion protection with Ex protection Ex ic/ex nl/ Ex na/ex td - Typical.3 V (= 318 Ω).3 V (= 318 Ω) 7.8 V (= 390 Ω) 7.8 V (= 390 Ω) -max..48 V (= 324 Ω).48 V (= 324 Ω) 8.3 V (= 415 Ω) 8.3 V (= 415 Ω) Without HART (DR53..) - Typical 7.9 V (= 395 Ω) max. 8.4 V (= 420 Ω) With HART (DR51..) - Typical. V (= 330 Ω). V (= 330 Ω) - - -max..72 V (= 33 Ω).72 V (= 33 Ω) - - With HART (DR52..) - Typical V (= 420 Ω) 8.4 V (= 420 Ω) 8.4 V (= 420 Ω) -max V (= 440 Ω) 8.8 V (= 440 Ω) 8.8 V (= 440 Ω) Static destruction limit ±40 ma ±40 ma - - Maximum internal capacitance C i Without HART nf 22 nf (at "nl") With HART nf 7 nf (at "nl") Maximum internal inductance L i Without HART mh 0.12 mh (at "nl") With HART mh 0.24 mh (at "nl") For connecting to circuits with the following peak values - - Intrinsically safe U i = 30 V I i = 100 ma P i = 1 W At "na" and "td": U n = 30 V DC I n = 100 ma at "nl": U i = 30 V I n = 100 ma Test voltage 840 V DC, 1 s Binary input BE1 (terminals 9/10; electrically connected to the basic device) Suitable only for floating contact; max. contact load <5μA at 3 V 3-/4-wire device (terminals 2/4 and /8) (DR52.. and DR53..) Power supply U H V DC V DC V DC V DC Current consumption I H (U H -7.5 V)/2.4 kω [ma] Maximum internal capacitance C i nf 22 nf (at "nl") Maximum internal inductance L i mh 0.12 mh (at "nl") For connecting to circuits with the following peak values - - Intrinsically safe U i = 30 V DC I i = 100 ma Pi = 1 W At "na" and "td": U n = 30 V DC I n = 100 ma at "nl": U i = 30 V DC I i = 100 ma Siemens FI /19

20 Technical specifications without Ex protection with Ex d protection (flameproof enclosure) with Ex i explosion protection with Ex protection Ex ic/ex nl/ Ex na/ex td Current input I W Rated signal range 0/ ma Load voltage at 20 ma 0.2 V (= 10 Ω) 0.2 V (= 10 Ω) 1 V (= 50 Ω) 1 V (= 50 Ω) Maximum internal capacitance C i nf 22 nf (at "nl") Maximum internal inductance L i mh 0.12 mh (at "nl") For connecting to circuits with the following peak values - - Intrinsically safe U i = 30 V DC Ii = 100 ma P i = 1 W At "na" and "td": U n = 30 V DC I n = 100 ma at "nl": U i = 30 V DC I i = 100 ma Electrical isolation between U H and I W between U H and I W between U H and I W (2 intrinsically safe circuits) between U H and I W Test voltage Binary input BE1 (terminals 9/10; electrically connected to the basic device) Design Connections, electrical Screw terminals Cable gland M20x1.5 or ½- 14 NPT Ex d certified cable gland M20x1.5, ½- 14 NPT or M25x1.5 Connections, pneumatic Certificates, approvals, explosion protection Permissible ambient temperature for operation Explosion protection as per ATEX/IECEx Explosion protection according to FM/CSA C ( F) 840 V DC, 1 s Suitable only for floating contact; max. contact load <5μA at 3 V 2.5 AWG28-12 M20x1.5 or ½- 14 NPT Female thread G¼ or ¼- 18 NPT T4: C ( F) T5: C ( F) T: C ( F) M20x1.5 or ½- 14 NPT At -10 C (+14 F) the display refresh rate of the indicator is limited. For basic devices with Ex protection the following applies: Only T4 is permissible when using I y module type DR4004-J. - Zone 1: Zone 1: Zone 2: II 2 G Ex d IIC T II 2 G Ex ia IIC T//4 Gb II 3 G Ex ic IIC T/T4 Gc II 3 G Ex nl IIC T/T4Gc II 3 G Ex na nl IIC T/T4 Gc Zone 22: II 3 D Ex td A22 IP T100 C - XP, Class I, Division 1 Class I, Zone 1, Ex d DIP, Class II, Division 1 DIP, Class III IS, Class I, Division 1 Class I, Division 1, Ex i Mounting location Zone 1 Zone 1 Zone 2/22 NI, Class I, Division 2 Class 1, Zone 2 /20 Siemens FI

21 Technical specifications with PROFIBUS PA without Ex protection with Ex d protection (flameproof enclosure) with Ex i explosion protection with Ex protection Ex ic/ex nl/ Ex na/ex td Input Power supply (terminals /7) Bus-supplied Bus voltage V V V V Bus connection with supply unit Intrinsically safe FISCO At "na" and "td": Un = 32 V DC at "nl": FNICO - Max. supply voltage U o V 17.5 V - Max. short-circuit current I o ma 570 ma -Max. power P o W - Bus connection with barrier Intrinsically safe at "nl" - Max. supply voltage U o V 32 V - Max. short-circuit current I o ma - -Max. power P o W - Current consumption 11.5 ma ± 10 % Additional error signal 0mA Maximum internal capacitance C i - - Negligible Negligible Maximum internal inductance L i µh 8 µh (at "nl") Safety shutdown can be activated with coding bridge (terminals 81/82; electrically isolated from the basic device) Input resistance > 20 kω Signal state "0" (shutdown active) V or unconnected Signal state "1" (shutdown not active) V Maximum internal capacitance C i - - Negligible Negligible Maximum internal inductance L i - - Negligible Negligible For connection to power supply with - - Intrinsically safe At "na", "nl" and "td" - Max. supply voltage U i V 30 V - Max. short-circuit current I i ma 100 ma -Max. power P oi W - Electrical isolation Between basic device and the input for safety shutdown, as well as the outputs of the option modules Test voltage Binary input BE1 for PROFIBUS (terminals 9/10; electrically connected to the basic device) Design Connections, electrical Screw terminals Cable gland M20x1.5 or ½-14 NPT Ex d certified cable gland M20x1.5; ½-14 NPT or M25x1.5 Connections, pneumatic The basic device and the input to the safety shutdown, as well as the outputs of the option modules, are separate, intrinsically safe circuits. 840 V DC, 1 s Suitable only for floating contact; max. contact load < 5 µa at 3 V 2.5 AWG28-12 M20x1.5 or ½-14 NPT Female thread G¼ or ¼- -18 NPT Between basic device and the input for safety shutdown, as well as the outputs of the option modules M20x1.5 or ½-14 NPT Siemens FI /21

22 Technical specifications Certificates, approvals, explosion protection Permissible ambient temperature for operation Explosion protection as per ATEX/IECEx Explosion protection according to FM/CSA without Ex protection C ( F) with Ex d protection (flameproof enclosure) T4: C ( F) T5: C ( F) T: C ( F) T4: ( ) T: C ( F) At -10 C (+14 F) the display refresh rate of the indicator is limited. For basic devices with Ex protection the following applies: Only T4 is permissible when using I y module type DR4004-J. - Zone 1: II 2 G Ex d IIC T - XP, Class I, Division 1 Class I, Zone 1, Ex d DIP, Class II, Division 1 DIP, Class III with Ex i explosion protection Zone 1: II 2 G Ex ia IIC T/4 Gb IS, Class I, Division 1 Class I, Division 1, Ex i with Ex protection Ex ic/ex nl/ Ex na/ex td Zone 2: II 3 G Ex ic IIC T/T4 Gc II 3 G Ex nl IIC T/T4Gc II 3 G Ex na nl IIC T/T4 Gc Zone 22: II 3 D Ex td A22 IP T100 C NI, Class I, Division 2 Class 1, Zone 2 Mounting location Zone 1 Zone 1 Zone 2/22 Communication Communication Layers 1 and +2 according to PROFIBUS PA, transmission technology according to IEC ; slave function; layer 7 (protocol layer) according to PROFIBUS DP, EN standard with the extended PROFIBUS functions (all data acyclic, manipulated variable, feedbacks and status also cyclic) C2 connections Four connections to master class 2 are supported; automatic connection setup 0 s after break in communication Device profile PROFIBUS PA profile B, version 3.0, more than 150 objects Response time to master message Typically 10 ms Device address 12 (when delivered) PC parameterizing software SIMATIC PDM; supports all device objects. The software is not included in the scope of delivery. /22 Siemens FI

23 Technical specifications with FOUNDATION Fieldbus without Ex protection with Ex d protection (flameproof enclosure) with Ex i explosion protection with Ex protection Ex ic/ex nl/ Ex na/ex td Input Power supply (terminals /7) Bus-supplied Bus voltage V V V V Bus connection with supply unit Intrinsically safe FISCO At "na" and "td": U n = 32 V DC at "nl": FNICO - Max. supply voltage U o V 17.5 V - Max. short-circuit current I o ma 570 ma -Max. power P o W - Bus connection with barrier Intrinsically safe at "nl" - Max. supply voltage U o V 32 V - Max. short-circuit current I o ma - -Max. power P o W - Current consumption 11.5 ma ± 10 % Additional error signal 0 ma Maximum internal capacitance C i - - Negligible Negligible Maximum internal inductance L i µh 8 µh (at "nl") Safety shutdown can be activated with coding bridge (terminals 81/82; electrically isolated from the basic device) Input resistance > 20 kω Signal state "0" (shutdown active) V or unconnected Signal state "1" (shutdown not active) V Maximum internal capacitance C i - - Negligible Negligible Maximum internal inductance L i - - Negligible Negligible For connection to power supply with - - Intrinsically safe At "na", "nl" and "td" - Max. supply voltage U i V 30 V - Max. short-circuit current I i ma 100 ma -Max. power P oi W - Electrical isolation Between basic device and the input for safety shutdown, as well as the outputs of the option modules The basic device and the input to the safety shutdown, as well as the outputs of the option modules, are separate, intrinsically safe circuits. Test voltage 840 V DC, 1 s Design Connections, electrical Screw terminals 2.5 AWG28-12 Cable gland M20x1.5 or ½-14 NPT Ex d certified cable gland M20x1.5, ½-14 NPT or M25x1.5 M20x1.5 or ½-14 NPT Connections, pneumatic Female thread G¼ or ¼- -18 NPT Between basic device and the input for safety shutdown, as well as the outputs of the option modules M20x1.5 or ½-14 NPT Siemens FI /23

24 Technical specifications Certificates, approvals, explosion protection Permissible ambient temperature for operation Explosion protection as per ATEX/IECEx Explosion protection according to FM/CSA without Ex protection C ( F) with Ex d protection (flameproof enclosure) T4: C ( F) T5: C ( F) T: C ( F) T4: ( ) T: C ( F) At -10 C (+14 F) the display refresh rate of the indicator is limited. For basic devices with Ex protection the following applies: Only T4 is permissible when using Iy module type DR4004-J. - Zone 1: II 2 G Ex d IIC T - XP, Class I, Division 1 Class I, Zone 1, Ex d DIP, Class II, Division 1 DIP, Class III with Ex i explosion protection Zone 1: II 2 G Ex ia IIC T/4 Gb IS, Class I, Division 1 Class I, Division 1, Ex i with Ex protection Ex ic/ex nl/ Ex na/ex td Zone 2: II 3 G Ex ic IIC T/T4 Gc II 3 G Ex nl IIC T/T4Gc II 3 G Ex na nl IIC T/T4 Gc Zone 22: II 3 D Ex td A22 IP T100 C NI, Class I, Division 2 Class 1, Zone 2 Mounting location Zone 1 Zone 1 Zone 2/22 Communication Communications group and class According to technical specification of the Fieldbus Foundation for H1 communication Function blocks Group 3, Class 31PS (Publisher Subscriber) 1 Resource Block (RB2) 1 Analog Output Function Block (AO) 1 PID Function Block (PID) 1 Transducer Block (Standard Advanced Positioner Valve) Execution times of the blocks AO: 0 ms PID: 80 ms Physical layer profile 123, 511 FF registration Tested with ITK 5.0 Device address 22 (when delivered) /24 Siemens FI

25 Technical specifications Technical specifications for option modules Certificates, approvals, explosion protection Explosion protection as per ATEX/IECEx Explosion protection according to FM/CSA Without Ex protection/with Ex protection Ex d With Ex n protection Ex i - Zone 1: II 2 G Ex ia IIC T/T4 Gb IS, Class I, Division 1 Class I, Division 1, Ex i Mounting location - Zone 1 Zone 2/22 Permissible ambient temperature for operation C ( F) With Ex protection Ex ic/ex nl/ Ex na/ex td Zone 2: II 3 G Ex ic IIC T/T4 Gc II 3 G Ex nl IIC T/T4 Gc II 3 G Ex na nl IIC T/T4 Gc Zone 22: II 3 D Ex td A22 IP T100 C NI, Class I Division 2 Class I Zone 2 T4: ( ) T: C ( F) Iy module type DR4004-J must only be used in T4. Alarm module DR4004-8A DR4004-A DR4004-A Binary alarm outputs A1, A2 and alarm output Signal state - High (not activated) Conductive, R = 1 kω, 2.1 ma 2.1 ma +3/-1 % *) - Low *) (activated) Blocked, I R <0µA 1.2 ma 1.2 ma *) Low is also the status when the basic device is faulty or is without additional electrical power supply. *) When used in the flameproof enclosure the current consumption must be limited to 10 ma per output. Switching threshold with supply to EN : U H = 8.2 V, R i = 1 kω Effective internal capacitance C i nf 5.2 nf (at "nl") Effective internal inductance Li - Negligible Negligible Power supply U H 35 V - - Connecting to circuits with the following peak values - Intrinsically safe switching amplifier to EN U i = 15.5 V DC I i = 25 ma P i = 4 mw Switching threshold with supply to EN : U H = 8.2 V, R i = 1 kω At "na" and "td": U H = 15.5 V DC at "nl": Ui i = 15.5 V DC I i = 25 ma Binary input BE2 Electrically connected to the basic device - Signal state 0 Floating contact, open - Signal state 1 Floating contact, closed - Contact load 3 V, 5 μa Electrically isolated from the basic device - Signal state V or open - Signal state 1 13 V - Natural resistance 25 kω Static destruction limit ± 35 V - - Effective internal inductance and capacitance - Negligible Negligible Connecting to circuits with the following peak values Electrical isolation Test voltage - Intrinsically safe U i = 25.2 V At "na" and "td": U n = 25.2 V DC at "nl": U i = 25.2 V DC The 3 outputs, the input BE2 and the basic device are electrically isolated from each other 840 V DC, 1 s Siemens FI /25

26 Technical specifications I y module DR4004-8J DR4004-J DR4004-J DC output for position feedback Rated signal range Total operating range 2-wire connection ma, short-circuit proof ma Power supply U H V V V External loads R B [kω] (U H [V] 12 V)/i [ma] Transmission error 0,3 % Temperature influence effect 0.1 %/10 K ( 0.1%/18 F) Resolution 0,1 % Residual ripple 1% Maximum internal capacitance C i - 11 nf 11 nf (at "nl") Maximum internal inductance L i - Negligible Negligible For connecting to circuits with the following peak values Electrical isolation Test voltage Without Ex protection/with Ex protection Ex d Electrically isolated from the basic device 840 V DC, 1 s With Ex n protection Ex i Intrinsically safe U i = 30 V DC I i = 100 ma P i = 1 W (T4 only) With Ex protection Ex ic/ex nl/ Ex na/ex td At "na" and "td": U n = 30 V DC I n = 100 ma P n = 1 W (T4 only) at "nl": U i = 30 V DC I i = 100 ma /2 Siemens FI

27 Technical specifications Without Ex protection With Ex n protection Ex i With Ex protection Ex ic/ex nl/ Ex na/ex td SIA module DR4004-8G DR4004-G DR4004-G Limit transmitter with slot-type initiators and alarm output Limit transmitter A1, A2 2-wire connection Connection 2-wire system to EN (NAMUR), for switching amplifier to be connected on load side Signal state Low (activated) < 1.2 ma 2 slot-type initiators Type SJ2-SN Function NC (normally closed) Effective internal capacitance C i - 41 nf 41 nf (at "nl") Effective internal inductance L i µh 100 µh (at "nl") Connecting to circuits with the following peak values Rated voltage 8 V current consumption: 3 ma (limit value not responded), 1 ma (limit value responded) Intrinsically safe switching amplifier EN U i = 15.5 V DC I i = 25 ma P i = 4 mw At "na" and "td": U n = DC 15.5 V P n = 4 mw at "nl": U i = DC 15.5 V I i = 25 ma Alarm output Connection On switching amplifier according to EN : (NAMUR), U H = 8.2 V, R i = 1 kω). Signal state High (not activated) R = 1.1 kω >2.1 ma > 2.1 ma Signal state Low (activated) R = 10 kω < 1.2 ma < 1.2 ma Effective internal capacitance C i nf 5.2 nf Effective internal inductance L i - Negligible Negligible Power supply U H U H 35 V DC I 20 ma - - Connecting to circuits with the following peak values - Intrinsically safe switching amplifier EN Ui i = 15.5 V DC I i = 25 ma P i = 4 mw At "na" and "td": U n = 15.5 V DC at "nl": U i = 15.5 V DC I i = 25 ma Electrical isolation The 3 outputs are electrically isolated from the basic device. Test voltage 840 V DC, 1 s Limit value contact module DR4004-8K DR4004-K DR4004-K Limit transmitter with mechanical switching contacts Max. switching current AC/DC 4 A Connecting to intrinsically safe circuits with the following peak values: U i = 30 V I i = 100 ma P i = 750 mw Max. switching voltage AC/DC 250 V/24 V 30 V DC 30 V DC Maximum internal capacitance C i - Negligible Negligible Maximum internal inductance L i - Negligible Negligible Alarm output Connection On switching amplifier according to EN : (NAMUR), - U H = 8.2 V, R i = 1 kω). Signal state High (not activated) R = 1.1 kω >2.1 ma > 2.1 ma Signal state Low (activated) R = 10 kω < 1.2 ma < 1.2 ma Maximum internal capacitance C i nf 5.2 nf (at "nl") Maximum internal inductance L i - Negligible Negligible Power supply U H U H 35 V DC I 20 ma - - Connecting to circuits with the following peak values - Intrinsically safe switching amplifier EN U i = 15.5 V DC I i = 25 ma P i = 4 mw Connecting to intrinsically safe circuits with the following peak values: at "nl": U i = 30 V I i = 100 ma At "na" and "td": U n = 15.5 V DC at "nl": U i = 15.5 V DC I i = 25 ma Siemens FI /27

28 Technical specifications EMC filter module EMC filter module is required for NCS sensor or external potentiometer. External position sensor (potentiometer or NCS; as option) with the following peak values: Maximum output voltage (U o ) - 5 V 5 V Maximum output current static (I o ) - 75 ma 75 ma Maximum output current shortterm (I s ) - 10 ma - Maximum output power (P o ) mw 120 mw Maximum external capacitance C o - 1 µf 1 µf Maximum external inductance L o - 1 mh 1 mh Test voltage 840 V DC, 1 s NCS sensor Position range Linear actuator mm ( "); up to 200 mm (7.87") on request Part-turn actuator Linearity (after correction by positioner) Linear actuator ± 1% Part-turn actuator ± 1% Hysteresis ± 0,2 % Continuous working temperature -40 C C (-40 F F), extended temperature range on request Vibration resistance Harmonic oscillations 7 mm (0.28"), Hz; 500 m/s2 (140 ft/s2), Hz (sine-wave) according to EN /05.9 Degree of protection of enclosure IP8/NEMA 4X For connecting to circuits with the following peak values Without Ex protection With Ex n protection Ex i With Ex protection Ex ic/ex nl/ Ex na/ex td - Intrinsically safe U i = 5 V DC at "nl": U i = 5 V DC Maximum internal capacitance C i - 10 nf 10 nf (at "nl") Maximum internal inductance L i µh 240 µh (at "nl") /28 Siemens FI

29 Selection and Ordering data electropneumatic positioner, without Ex protection, with "Ex i" and with "Ex n" Order No. D R A7 Version 2-wire (4 to 20 ma) Without HART } 0 With HART, not explosion-protected } 1 2-, 3-, 4-wire (0/4 to 20 ma) With HART, explosion-protected } 2 Without HART, not explosionprotected } 3 PROFIBUS PA connection } 5 FOUNDATION Fieldbus connection } For actuator single-acting } 1 double-acting } 2 Enclosure Makrolon } 0 Aluminum; only single-acting } 1 1 Stainless steel (without window) } 2 Explosion protection Without } N In type of protection } E (ATEX/IECEx/FM/CSA) intrinsic safety "Ex ia", zone 1 In type of protection D (ATEX/IECEx/FM/CSA) 1) non-sparking "Ex na", zone 2 energy-limited "Ex nl", zone 2 In type of protection (ATEX/IECEx) dust protection via enclosure "Ex td", zone 22 In type of protection F (ATEX/IECEx/FM/CSA) 2) 3) intrinsic safety "Ex ia", zone 1 intrinsic safety "Ex ic", zone 2 non-sparking "Ex na", zone 2 energy-limited "Ex nl", zone 2 In type of protection G (ATEX/IECEx/FM/CSA) 2) non-sparking "Ex na", zone 2 energy-limited "Ex nl", zone 2 In type of protection K 1) 3) (ATEX/IECEx/FM/CSA) intrinsic safety "Ex ia", zone 1 intrinsic safety "Ex ic", zone 2 non-sparking "Ex na", zone 2 energy-limited "Ex nl", zone 2 In type of protection (ATEX/IECEx) dust protection via enclosure "Ex td", zone 22 Connection thread electrical/pneumatic M20 x 1.5 / G¼ } G ½-14 NPT / ¼-18 NPT 4) N M20 x 1.5 / ¼-18 NPT M ½-14 NPT / G¼ 1) P With plug M12 / G¼ R With plug M12 / ¼-18 NPT S Limit monitor Installed, incl. 2nd cable gland Without } 0 Alarm module; electronic 1 (DR4004-.A) SIA module; slot-type initiators 2 (DR4004-.G) Limit value contact module (mechanical switching contacts (DR4004-.K) 3 Selection and Ordering data Selection and Ordering data Order No. electropneumatic D R A7 positioner, without Ex protection, with "Ex i" and with "Ex n" Option modules Installed, incl. 2nd cable gland Without } 0 Iy module for position feedback signal ( ma) (DR4004-.J) 1 EMC filter module for external position 2 sensor in the enclosure (C73451-A430-D23), NCS sensor DR4004-8/NN1/2/30 and external position sensing with non-siemens potentiometer Iy module and EMC filter module for 3 external position sensor Customer-specific design Without } 0 Brief instructions German/English } A French/Spanish/Italian B Mounted pressure gauge block Without } 0 Gauge made of plastic, block made 1 of aluminium, single-acting G¼, scaled in MPa and bar Gauge made of plastic, block made 2 of aluminium, double-acting G¼, scaled in MPa and bar Gauge made of plastic, block made 3 of aluminium, single-acting ¼-18 NPT, scaled in MPa and psi Gauge made of plastic, block made 4 of aluminium, double-acting ¼-18 NPT, scaled in MPa and psi Gauge version with order code R. (see "Further designs") 9 Further designs Order code Add "-Z" to Order No. and specify order code. Gauge made of steel, R1A block made of aluminium, single-acting G¼, scaled in MPa, bar, psi Gauge made of steel, R2A Block made of aluminium, double-acting G¼, scaled in MPa, bar, psi Gauge made of steel, R1B Block made of aluminium, single-acting ¼-18 NPT, scaled in MPa, bar, psi Gauge made of steel, R2B Block made of aluminium, double-acting ¼-18 NPT, scaled in MPa, bar, psi Gauge made of stainless steel 31, R1C Block made of stainless steel 31, single-acting G¼, scaled in MPa, bar, psi Gauge made of stainless steel 31, R2C Block made of stainless steel 31, double-acting G¼, scaled in MPa, bar, psi Gauge made of stainless steel 31 R1D Block made of stainless steel 31, singleacting ¼-18 NPT, scaled in MPa, bar, psi Gauge made of stainless steel 31 R2D Block made of stainless steel 31, doubleacting ¼-18 NPT, scaled in MPa, bar, psi Pneumatic terminal block made of K18 stainless steel 31 For device versions in Makrolon enclosure Version with stainless steel sound A40 absorbers Standard with stainless steel enclosure Siemens FI /29

30 Selection and Ordering data Selection and Ordering data electropneumatic positioner, without Ex protection, with "Ex i" and with "Ex n" Measuring point number (TAG No.) Y17 5) Max. 8 characters for HART, max. 32 characters for PROFIBUS PA, FOUNDATION Fieldbus and ma, specify in plain text: Y17:... Measuring point description Y15 5) Max. 1 characters for HART, max. 32 characters for PROFIBUS PA, FOUNDATION Fieldbus and ma, specify in plain text: Y15:... Measuring point text Y1 5) Max. 24 characters for HART, max. 32 characters for PROFIBUS PA, FOUNDATION Fieldbus and ma, specify in plain text: Y1:... TAG plate made of stainless steel, A20 5) 3-line Text line 1: Plain text from Y17 Text line 2: Plain text from Y15 Text line 3: Plain text from Y1 Preset bus address Y25 5) Specify in plain text: Y25:... (only for DR55.. and DR5..) } Available ex stock (select combinations) Order No. D R A7 1) Enclosure: Aluminium or stainless steel, each without inspection window in the cover. 2) Enclosure: Aluminium or Makrolon, each with inspection window in the cover. 3) Available in 01/2011 4) Connection thread, electrical using NPT adapter on Makrolon and aluminum enclosure. 5) Only for Makrolon enclosure, for other enclosures on request. /30 Siemens FI

31 Selection and Ordering data electropneumatic positioner, Ex d explosion protection, aluminum enclosure, without cable gland Order No. D R E A7 Version 2-wire (4 to 20 ma) Without HART } 0 With HART 1 2-, 3-, 4-wire (0/4 to 20 ma) With HART } 2 Without HART 3 PROFIBUS PA connection 5 FOUNDATION Fieldbus connection For actuator single-acting } 1 double-acting } 2 Connection thread electrical/pneumatic M20 x 1.5 / G¼ } G ½-14 NPT / ¼-18 NPT } N M20 x 1.5 / ¼-18 NPT M ½-14 NPT / G¼ P M25x1.5 / G¼ Q Limit monitor Built-in Without } 0 Alarm module; electronic 1 (DR4004-8A) Option modules Built-in Without } 0 Iy module for position feedback 1 signal ( ma) (DR4004-8J) Customer-specific design Without } 0 Brief instructions German/English } A French/Spanish/Italian B Mounted pressure gauge block Without } 0 Gauge made of plastic, block made 1 of aluminium, single-acting G¼, scaled in MPa and bar Gauge made of plastic, block made 2 of aluminium, double-acting G¼, scaled in MPa and bar Gauge made of plastic, block made 3 of aluminium, single-acting ¼-18 NPT, scaled in MPa and psi Gauge made of plastic, block made of aluminium, double-acting ¼-18 NPT, scaled in MPa and psi 4 Selection and Ordering data Selection and Ordering data Order No. electropneumatic positioner, Ex d explosion protection, D R E A7 aluminum enclosure, without cable gland Further designs Order code Add "-Z" to Order No. and specify order code. Measuring point number (TAG No.) Y17 1) Max. 8 characters for HART, max. 32 characters for PROFIBUS PA and FOUNDATION Fieldbus, specify in plain text: Y17:... Measuring point description Y15 1) Max. 1 characters for HART, max. 32 characters for PROFIBUS PA and FOUNDATION Fieldbus, specify in plain text: Y15:... Measuring point text Y1 1) Max. 24 characters for HART, max. 32 characters for PROFIBUS PA and FOUNDATION Fieldbus, specify in plain text: Y1:... TAG plate made of stainless steel, A20 1) 3-line Text line 1: Plain text from Y17 Text line 2: Plain text from Y15 Text line 3: Plain text from Y1 Preset bus address Y25 1) Specify in plain text: Y25:... only for DR55.. and DR5..) } Available ex stock (select combinations) 1) On request. Siemens FI /31

32 Selection and Ordering data Accessories Selection and Ordering data Order No. Selection and Ordering data Order No. Accessories ly module for position feedback signal (4 to 20 ma) Without explosion protection } DR4004-8J With explosion protection CENELEC/ATEX } DR4004-J With explosion protection FM/CSA DR4004-7J Alarm module for 3 alarm outputs and 1 binary input (functionality: 2 limit monitors, 1 fault alarm, 1 binary input) Without explosion protection } DR4004-8A With explosion protection CENELEC/ATEX } DR4004-A With explosion protection FM/CSA DR4004-7A SIA module (slot-type initiator alarm module, not for Ex d version) Without explosion protection } DR4004-8G With CENELEC/ATEX and FM/CSA explosion } DR4004-G protection Limit value contact module (with mechanical ground contacts, not for Ex d version) Without explosion protection } DR4004-8K With explosion protection } DR4004-K EMC filter module for connection of external C73451-A430-D23 position sensor (10 kω) or NCS sensor (not for Ex d version) Selection and Ordering data Order No. Accessories NCS sensor D R N N 7 0 for non-contacting detection of position (not for Ex d version), cable length m (19.8 ft) Non explosion-proof 8 Explosion protection, Ex i For part-turn actuators, without mounting 1 console For linear actuators up to 14 mm (0.55 inch), 2 without mounting bracket For linear actuators >14 mm (0.55 inch), 3 up to 130 mm (5.12 inch), mounting kit same as for (separate ordering item) The EMC filter module is additionally required for the controller unit (separate ordering item, see below). External position detection system (with C73451-A430-D78 explosion protection to CENELEC/ATEX, Ex i) for separate mounting of position sensor and controller unit (not for Ex d version), comprising Makrolon enclosure with integral potentiometer and sliding clutch (without electronics and valve block) The EMC filter module is additionally required for the controller unit. (separate ordering item, see above). Gauge block with 2 gauges made of plastic, block made of aluminium, } DR4004-1M single-acting G¼, scaled in Mpa and bar 3 gauges made of plastic, block made of aluminium, } DR4004-2M double-acting G¼, scaled in Mpa and bar 2 gauges made of plastic, block made of } DR4004-1MN aluminium, single-acting G¼-18 NPT, scaled in Mpa and psi 3 gauges made of plastic, block made of } DR4004-2MN aluminium, double-acting G¼-18 NPT, scaled in Mpa and psi 2 gauges made of steel DR4004-1P Block made of aluminum, single-acting G¼, scaled in Mpa, bar, ps 3 gauges made of steel DR4004-2P Block made of aluminum, double-acting G¼, scaled in Mpa, bar, ps 2 gauges made of steel DR4004-1PN Block made of aluminum, single-acting ¼-18 NPT, scaled in Mpa, bar, psi 3 gauges made of steel DR4004-2PN Block made of aluminum, double-acting ¼-18 NPT, scaled in Mpa, bar, psi 2 gauges made of stainless steel 31 DR4004-1Q Block made of stainless steel 31, single-acting G¼, scaled in Mpa, bar, psi 3 gauges made of stainless steel 31 DR4004-2Q Block made of stainless steel 31, double-acting G¼, scaled in Mpa, bar, psi 2 gauges made of stainless steel 31 DR4004-1QN Block made of stainless steel 31, single-acting ¼-18 NPT, scaled in Mpa, bar, psi 3 gauges made of stainless steel 31 Block made of stainless steel 31, double-acting ¼-18 NPT, scaled in Mpa, bar, psi DR4004-2QN Pneumatic terminal block made of stainless steel 31 to replace the pneumatic terminal block made of aluminium for with Makrolon enclosure single-acting with G¼ DR4004-1R double-acting with G¼ DR4004-2R single-acting with ¼-18 NPT DR4004-1RN double-acting with ¼-18 NPT DR4004-2RN Mounting kit for NAMUR part-turn actuators (VDI/VDE 3845, with plastic coupling wheel, } C) DR4004-8D without mounting console) (VDI/VDE 3845, with stainless steel coupling, } TGX: without mounting console) The following mounting consoles can be used with the NAMUR part-turn actuator mounting kit DR4004-8D. Size W x L x H (H = height of shaft butt) 30 x 80 x 20 mm } C) TGX: x 80 x 30 mm } C) TGX: x 130 x 30 mm } C) TGX: x 130 x 50 mm } C) TGX: C) Subject to export regulations AL: N, ECCN: EAR99. /32 Siemens FI

33 Selection and Ordering data Accessories Mounting kit for other part-turn actuators The following mounting consoles can be used together with the NAMUR part-turn actuator mounting kit DR4004-8D. SPX (DEZURIK) Power Rac, sizes R1, R1A, } C) TGX: R2 and R2A Masoneilan Camflex II } C) TGX: Fisher 1051/1052/101, sizes 30, 40, 0 to 70 } C) TGX: Fisher 1051/1052, size 33 } C) TGX: Mounting kit for NAMUR-linear actuators NAMUR linear actuator mounting kit with short } DR4004-8V lever arm (2 to 35 mm) Lever arm for travels from 35 mm to 130 cm } DR4004-8L (1.38 inch to 5.12 inch) Reduced mounting kit for linear actuator (like } DR4004-8VK DR4004-8V but without fixing angle and U-bolt), with short lever with up to 35 mm travel (1.38 inch) Reduced mounting kit for linear actuator (like } DR4004-8VL DR4004-8V but without fixing angle and U-bolt), with short lever with up to 35 mm travel (1.38 inch) Roll and disk made of stainless steel 31 DR4004-3N for replacement of the Teflon roll and aluminum disk in the DR4004-8, -8VK and -8VL mounting kits for NAMUR linear actuators Two terminal blocks made of stainless steel DR4004-3M 31 for replacement of the aluminum terminal blocks in the DR4004-8V, -8VK and -8VL mounting kits for NAMUR linear actuators Mounting kit for other linear actuators Retrofitting kit for Moore series 72 and 750 } C) TGX: valve positioners Fisher type 57/7, size 30 to 80 } C) TGX: Samson actuator type 3277 } DR4004-8S (yoke dimension (H5) = 101 mm 2 (integrated connection without tube), not for Ex d Connection block, for safety solenoid valve with extended mounting flange to NAMUR For mounting to IEC 534- } DR4004-1B For SAMSON actuator (integrated mounting) } DR4004-1C 1) see above Pipe mounting Additional actuator components can be found at the following Internet address: Customer-specific mounting kits available on request. Mounting bracket for pipe mounting of the } C) TGX: positioner (e.g. when using the NCS sensor) Documentation (see notes below) Instruction Manual with and without HART German A5E English A5E French/Italian/Spanish A5E Instruction Manual for PROFIBUS PA German A5E English A5E French/Italian/Spanish A5E Instruction Manual FOUNDATION Fieldbus German A5E English A5E French/Italian/Spanish A5E Instruction Manual for NCS Sensor German/English/French/Spanish/Italian A5E device documentation CD-ROM with complete documentation for all A5E device versions SITRANS I200 output isolator HART (see "SITRANS I supply units and isolation amplifiers ) with 24 V DC power supply } 7NG4131-0AA00 HART modem for connecting to PC or laptop with RS232 interface } D) 7MF4997-1DA with USB interface } D) 7MF4997-1DB } Available ex stock. 1) Only together with DR4004-8S and DR4004-1M. C) Subject to export regulations AL: N, ECCN: EAR99. D) Subject to export regulations AL: N, ECCN: EAR99H. Note: All the above mentioned manuals are included on CD-ROM and can be downloaded from Scope of delivery for positioner 1 positioner as ordered 1 CD-ROM with the complete documentation for all versions and accessories Manual " - Configuration At a Glance" Siemens FI /33

34 Dimensional drawings Dimensional drawings 50 x 4 (1.97 x 0.1) x M 185 (7.28) 4) 50 x 4 (1.97 x 0.1) x M 2) 95 (3.74) All air connections 11,2 (0.44) G 1/4 or 1/4 NPT 84 (3.31) 29,5 (1.1) 29,5 (1.1) 29,5 (1.1) 1) 72 (2.83) 59 (2.32) 185 (7.28) 4) All air connections G 1/4 or 1/4 NPT 11,2 (0.44) 3) 9, (3.80) M20 x 1.5 Stainless steel version, values: 1) 74 (2.91) 2) 99 (3.89) 3) 98 (3.8) 4) Dimension at electrical connection ½-14 NPT (with adapter) 203 mm Makrolon and stainless steel enclosure (top), aluminum enclosure (center), Makrolon and aluminum enclosure (bottom), dimensions in mm (inch) M8, 14 (0.55) deep (4x) 5 (2.5) 43 (1.9) M, 11 (0.43) deep (4x) Y1 23 (0.91) 5 (0.2) 0 (2.3) Ø50 (1.97) 7,75 (0.3) all air connections G1/4 or 1/4-NPT 34 (1.34) 25 (0.98) 10,25 (0.4) 4,5 (1.8) 19,25 (0.3) M, 8 (0.31) deep (2x) M20x1,5, M25x1,5 or 1/2-NPT (2x) 1) 7,5 (0.3) E 12 (0.47) 87,2 (3.43) 25,7 (1.01) 7 (0.28) 14,3 (0.5) 129,5 (5.1) 3,5 (0.14) 82,5 (3.25) Ø13,5 (5.37) 158,5 (.24) 33,5 (1.32) 33,5 (1.32) Ø8 (7) h9 235,3 (9.2) 1) Connection 238/Y2 only for double-action version Flameproof enclosure left, dimensions in mm (inch) /34 Siemens FI

35 > 4 mm (0.1) Mounting level of positioner M 4 +0,1 ( ) a b 25 (0.98) Mounting plate Schematics Electric connection of 2-, 3- and 4-wire device (DR52.. and DR53..) Devices of types DR52.. and DR53.. can be operated in a 2-, 3- and 4-wire system. I + 3 R 250 W if req. 1) l y = ma l H Part-turn actuator a = 4 (0.1) b = 12 (0.47) l W- 7 8 Ø35 (1.38) HART modem PC/Laptop,5 (0.2) 1) Only required with current sources not conforming to HART electropneumatic positioner, example of connection for communication through HART for DR52.. F05-Lkr.- Ø50 (1.97) Two-wire system Mounting onto part-turn actuators; mounting consoles (scope of delivery of actuator manufacturer), extract from VDI/VDE 3845, dimensions in mm (inch) J ma Schematics Electric connection of 2-wire devices (DR50.. and DR51..) Devices of types DR50.. and DR51.. are operated in a 2-wire system BE1 Two-wire system J ma BE1 Three-/Four-wire system V ) electropneumatic positioner, input circuit for DR50.. and DR51.. Electric connection of PROFIBUS PA device (DR55..) and Foundation Fieldbus device (DR5..) J 0/ ma BE V ) 1) Jumper between 5 and 7 only for three-wire system electropneumatic positioner, input circuits for DR52.. and DR53.. PROFIBUS PA and FOUNDATION Fieldbus connection + 24 V BE1 1) Input for safety shutdown (activated using coding jumper) PA and FF electropneumatic positioner, input circuit for DR55.. and DR5.. Siemens FI /35

36 Mounting kit Mounting kit for NAMUR linear actuators 1 mounting bracket 2 mounting prisms 1 U-bracket 1 lever arm with adjustable pick-up roll 2 U-bolts Various screws and lock washers Mounting of on linear actuators Mounting of Ex d on linear actuators /3 Siemens FI

37 Mounting kit Mounting kit for NAMUR part-turn actuators 1 coupling wheel 1 driver pin 8 scales 1 pointer Various screws and lock washers Caution: The mounting consoles and the screws for mounting onto the part-turn actuator are not included in the scope of delivery and must be provided by the customer (see "Technical specifications") Mounting of on part-turn actuators Mounting of Ex d on part-turn actuators More information Training Refer to Catalog ITC for details of training courses for these devices. Special versions On request 7 Siemens FI /37

Positioners SIPART PS2. Technical description. 6/12 Siemens FI Benefits. Overview

Positioners SIPART PS2. Technical description. 6/12 Siemens FI Benefits. Overview Positioners Siemens AG 2010 Technical description Overview Electropneumatic positioner in the Makrolon enclosure Ex d electropneumatic positioner in flameproof aluminium enclosure (Ex d) in stainless steel

More information

Electropneumatic positioners SIPART PS2

Electropneumatic positioners SIPART PS2 Electropneumatic positioners /2 Product overview /3 /3 Technical description /8 Technical specifications /8 - all versions /9 - /11 - PA /13 - FF /15 - Option modules /18 Ordering data /18 -, PS2 PA, PS2

More information

Electropneumatic positioners SIPART PS2

Electropneumatic positioners SIPART PS2 Electropneumatic positioners /2 Product overview /3 /4 Technical description /7 Technical Specifications /7 - all versions /8 - /10 - PA /12 - FF /14 - Option modules /1 Ordering data /1 -, PS2 PA, PS2

More information

Technical description

Technical description Technical description Overview electropneumatic positioner EEx d electropneumatic positioner in flameproof casing in stainless steel casing The electropneumatic positioner is used to control the final

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening angle 24 to

More information

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication Series 3731 Electropneumatic Ex d Positioner Type 3731-5 with FOUNDATION TM Fieldbus communication Application Positioner for attachment to pneumatic control valves Travel: 3.6 to 200 mm Opening angle:

More information

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 Type Electropneumatic Ex d Positioner with HART communication Series 3731 Type 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner Data Sheet T 8394 EN Series 3725 Type 3725 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented

More information

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors Series 3730 Electropneumatic Positioner Type 3730-6 with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300 mm Opening angle 24 to

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8384-4 EN Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300

More information

Electropneumatic Positioner Type and Type with HART communication

Electropneumatic Positioner Type and Type with HART communication Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-adjusting, automatic

More information

Refer to attachment for more details. Andreas Meyer

Refer to attachment for more details. Andreas Meyer IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

High-precision valve control using intelligent positioners. sipart

High-precision valve control using intelligent positioners. sipart High-precision valve control using intelligent positioners sipart The SIPART PS2 electropneumatic positioner is number 1 in its field by a very wide margin. Our past experience gathered from 15 years in

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

SideControl Positioner

SideControl Positioner SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC

More information

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors Series 3730 Type 3730-6 Electropneumatic Positioner with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-2 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Series Electropneumatic Positioner Type and Type with HART communication

Series Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication R V Data Sheet 12.07 DS EVE0105 -(en) SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication The intelligent positioner SRD991 is designed to operate

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8384-3 EN Series 3730 Type 3730-3 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Type Electropneumatic Positioner with HART communication

Series 3730 Type Electropneumatic Positioner with HART communication Series 3730 Type 3730-3 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic

More information

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner SideControl Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown. SVI II ESD SIL3 Partial Stroke Test Device October 2007 BW5000-ESD The only SIL3 Smart ESD device that is live during and after a shutdown. Patents Pending What is the SVI II ESD? The SVI II ESD is the

More information

Get to know our positioner! One that masters everything: SIPART PS2. Flexibility for all challenges. siemens.com/positioner

Get to know our positioner! One that masters everything: SIPART PS2. Flexibility for all challenges. siemens.com/positioner Get to know our positioner! One that masters everything: SIPART PS2 Flexibility for all challenges siemens.com/positioner The proven multi-talent SIPART PS2 SIPART PS2 is currently the most widely used

More information

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195 Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus

More information

Operating Instructions SIPART. Electropneumatic positioners SIPART PS2 with PROFIBUS PA. Edition 10/2013. Answers for industry.

Operating Instructions SIPART. Electropneumatic positioners SIPART PS2 with PROFIBUS PA. Edition 10/2013. Answers for industry. SIPART Electropneumatic positioners Operating Instructions Edition 10/2013 Answers for industry. Introduction 1 Safety information 2 SIPART Electropneumatic positioner Operating Instructions Description

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview for flexible and cost-effective temperature measurements Supports the standard (HART V 7.1) Very high security level for wireless data transmission Built-in local user interface (LUI) with -button

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX Metso s Neles NDX is the next generation intelligent valve controller working on all type of control valves and in all industry areas. It guarantees end product

More information

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology VVP10-H HART VALVE POSITIONER Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol Electronic Coil Technology Non-Contact Position Sensor (Hall Sensor) 4-20 ma NAMUR NE

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

NELES ND7000 DIGITAL VALVE CONTROLLER

NELES ND7000 DIGITAL VALVE CONTROLLER NELES ND7000 DIGITAL VALVE CONTROLLER Metso's Neles ND7000 is a digital valve controller designed to operate on all control valve actuators and in all industry areas. ND7000 is a reliable and future-proof

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown.

II ESD. SIL3 Partial Stroke Test Device. The only SIL3 Smart ESD device that is live during and after a shutdown. SVI II ESD SIL3 Partial Stroke Test Device The only SIL3 Smart ESD device that is live during and after a shutdown. W h a t i s t h e S V I I I E S D? The SVI II ESD is the latest technology in emergency

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Electropneumatic Positioner for Linear and Rotary Actuators. Order No. C79000-G7476-C158-1

Electropneumatic Positioner for Linear and Rotary Actuators. Order No. C79000-G7476-C158-1 SIPART PS2 SIPART PS2 PA Electropneumatic Positioner for Linear and Rotary Actuators 6DR400x-xx 6DR410x-xx Manual Order No. C79000-G7476-C158-1 SIPART, SITRANS, SIMATIC are Siemens registered trademarks.

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Digital electropneumatic Process Controller

Digital electropneumatic Process Controller Digital electropneumatic Process Controller Type 879 can be combined with Compact and robust design Easy Start-up using tune function of the Positioner and Process controller Integrated diagnostic functions

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. PositionMaster EDP300 Digital Positioner

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. PositionMaster EDP300 Digital Positioner ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET PositionMaster EDP300 Digital Positioner 2 POSITIONMASTER EDP300 DIGITAL POSITIONER DS/EDP300-EN REV. D Compact, well-proven, and flexible High air capacity

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

General. Remote I/O A4/1.

General. Remote I/O A4/1. www.stahl.de > Intrinsically safe Ex ia IIC, Ex e, Ex na or Ex nl inputs and outputs > Fieldbus communication: Modbus RTU, Profibus DP V0 and DP V1 HART, Industrial Ethernet, Modbus TCP, EtherNet/IP, PROFINET

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner

Mounting and Operating Instructions EB EN ( ) Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-6 Electropneumatic Positioner with HART communication and pressure sensors Old design New design Mounting and Operating Instructions EB 8384-6 EN (1300-1623) Firmware version 1.11

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31 Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Configuration. Installation

Configuration. Installation Overview SITRANS LR20 measures superbly in small vessels and in tanks/vessels up to 10 m (32 ft) on materials with dk > 3. Key Applications: liquid bulk storage tanks, process vessels with agitators, vaporous

More information

Type i2p-100 Electro-Pneumatic Transducer

Type i2p-100 Electro-Pneumatic Transducer Product Bulletin i2p-100 Transducer Type i2p-100 Electro-Pneumatic Transducer The Type i2p-100 electro-pneumatic transducer, shown in figure 1, uses a patented converter module that converts a milliampere

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Siemens AG 009 SITRANS P80 Overview Application The SITRANS P80 is a WirelessHART field device for measuring absolute and gauge pressure. The measuring ranges for absolute and gauge pressure measurements

More information

Positioner CMSX-...-C-U-F1-...

Positioner CMSX-...-C-U-F1-... Positioner CMSX-...-C-U-F-.... CMSX-SE-... (linear) 5 Festo AG & Co. KG Postfach Esslingen Germany +9-0 www.festo.com (en) Operating instructions 80595 0a [80595] aj 9 8 Housing cover Inspection window

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information