1 ITEM:- Supply and Installation of Servers for Private Cloud Annexure Tender No: IIT Bombay is setting up a cloud to host important applications and data for a national project. The cloud is to be built using standard servers and open source software components. We propose to use Ubuntu as the base operating system, and KVM/VMware as the virtualization layer. Our applications use open source tools and packages such as, MySQL, MongoDB, Drupal, Hadoop, etc.. We have experience in establishing such clouds, and have used commodity hardware. The software is capable of pooling storage capacities of hard disks and SSDs, and uses eraser codes to provide high availability. In order to obtain very low latency transfers, we use RDMA protocol, which is to be supported by the network interface card. The basic infrastructure including modular racks (4 numbers 42U racks) with cooling, UPS, switches for server interconnect, and hardware firewall, are being procured separately. This tender is for supply and installation of standard servers, with specific configuration as described in this document. It has been decided to procure servers manufactured by OEMS appearing in the leaders quadrant of the Gartner Magic Quadrant for Modular Servers (Published 23 May 2016). We note that there are 3 OEMs listed in the leaders quadrant: Cisco, Dell, and HPE. (Detailed Terms, Technical Specifications, and Bidding Format) 1. Terms of supply 1.1 Introduction This section describes the main objective to be achieved through this procurement. (i) IIT Bombay wishes to set up a cloud infrastructure, for an important national project. The project envisages storage of a very large number of digital assets and associated metadata. These are to be made accessible to all, through appropriate provisions for multilingual search. The software applications which will run on the infrastructure, are mainly being developed jointly by several partner institutions. The applications developed for this project, will also be released in open source. (ii) It is proposed to build the cloud using commodity hardware and open source software. We have established such a mini cloud two years ago, using locally assembled servers supplied by our rate contract vendors. The proposed setup is being established for a nationally important project, therefore it has been decided to deploy only those servers offered by OEMs which are listed in the Leaders Quadrant of the Gartner report. However, Page 1 of 16

2 no special hardware or proprietary software offered by these OEMs along with the basic servers, is to be included in the technical bid. Apart from the base configuration, the servers are to be populated by prescribed component subsystems such as SSDs, HDDs, NVMe cards, and Network Adapters supporting RDMA protocol. (iii) The cloud will be housed in 42U Racks (4 No.) in the modular Data Centre being established in the old CSE department building at IIT Bombay. The power will be supplied using a modular UPS of 60kVA capacity. Racks will be cooled using a closed loop in-the-row mechanism with up to 10 kva heat load per rack. The Data Centre will be protected by a fire suppression system. The server infrastructure will be connected to the internet with10gbps connectivity, through hardware firewalls. The interconnect between servers will be provided by 4 switches, one housed in each rack. These, along with prescribed additional Network Cards, are to provide RDMA over Converged Ethernet (RoCE) feature. We have chosen to use the following open source components to manage the cloud: KVM or VMware (ESXi) as hypervisor, Linux (Ubuntu 16.04), OpenVstorage and attendant management dashboards. All of these are open source software. Page 2 of 16

3 1.2 Bidding process and qualification criteria for bidders/bids (a) Detail Bid evaluation Under the two bid system, first the technical bids will be opened on the date and time an - nounced. A detailed evaluation will be carried out for compliance of the offered products with the technical specifications. A short list of technically qualified bidders, will be prepared at the end of this assessment exercise. Commercial bids of only the qualified shortlisted bidders, will be opened on the date and time announced. The bidder quoting the lowest total all-inclusive price, will be announced, and will be winner of the tender. Please note that the price quoted for the optional items (post warranty AMC for years 4 and 5 respectively), will not be considered for determining the lowest bid. A Letter of Intent (LoI) will be issued to the winning bidder, and the delivery period permitted, will be counted from the date of LoI. A Purchase Order (PO) will be issued after due internal process of audit and approvals. The winning bidder has to provide a 3-year Performance Bank Guarantee (PBG) of 5% of the total bid value, within 15 days of the issue of PO. 1.3 Eligibility The following eligibility criteria are over and above the general criteria defined in the Institute tender document. (i) As mentioned in the introduction, we are seeking standard servers manufactured by OEMs appearing in the Leaders Quadrant of the Gartner Magic Quadrant report published on 23 May These are Cisco, Dell, and HPE. Only those bidders are eligible to quote, who have a business arrangement with any one of these OEMs. (ii) IIT Bombay is in the process of testing and certifying specific models from each of the OEMs, which meet the technical specifications. Each OEM will be given a certificate of acceptability by IIT Bombay, specifying the model/part number of servers and other component subsystems. Bidders must quote only models/part numbers so certified. (iii) A bidder may choose to bid for servers made by any of these OEMs. However, a bidder can submit bids for servers from only one OEM of their choice. (iv) Each bidder must submit an Authorization Letter from the OEM, authorizing the bidder to bid on behalf of the OEM. It is to be noted that, warranty support during 3 years (and later, if the Institute uses the option of extending the AMC for 4 th and 5 th year) must be offered, with Next Business Day (NBD) part replacement guaranteed. IIT Bombay must have an option of directly registering a fault report with the OEM. Page 3 of 16

4 1.4 Supply, Installation, and Acceptance The winning bidder must deliver all material within 6 weeks of receiving the Letter of Intent. After the supply, a physical audit will be carried out to ascertain that the servers are supplied with approved component subsystems. The winning bidder must then install the servers in the 4 racks of our modular Data Center, as directed by the project staff. Upon completion of the installation, tests will be run to ascertain that the supplied servers with the stipulated configuration, successfully run the tests for compliance. 1.5 Technical specifications for Server configurations There are several technical features which are common to all the servers, while some features are specific to each server type. These are listed in the following subsections: Page 4 of 16

5 (a) Specifications common to all servers S NO Component Description 1 Processor Server should be populated with 2Nos of Intel Xeon E V4 10 Core Processor, 2.20GHz, 25M Cache, 8GT/s QPI 2 Chipset Intel C610 Series Chipset or Higher 3 Memory Server to be populated with 256GB DDR4 ECC RAM (1600MHz or higher) with 32 GB Modules 4 DIMM Slots Should be capable of accommodating a minimum of 512GB RAM using 32 GB Modules 5 Memory Property Advanced ECC memory protection, Memory mirroring or Equivalent 6 SD Cards 2 X 8Gb Internal SD Modules, should support redundancy 7 RAID Controller Hardware RAID controller should expose individual disks to BIOS. It should support 8 drives in JBOD mode, with a total throughput of 12Gb/s cumulatively across all ports. RAID controller should support standard Ubuntu16.04 drivers 8 Ethernet Ports 2 * 1 GbE multifunctional network ports 9 Additional network card 10 Graphics Controller Dual port Mellanox Ethernet Adapter Card ConnectX -4 Lx EN (Copper Support) 10 Gb/s speeds, Low latency RDMA over Converged Ethernet Hardware-based I/O virtualization, RoHS-R6 Minimum 8 MB Memory 11 Cooling Fans Redundant hot swappable fully populated cooling fans. 12 Server Management The server should come with systems management licensed software from the OEM with Remote Power On and Power Off, Remote KVM, monitoring, alerting, trouble shooting; should have dedicated 1G port for management. 13 Rails Must be supplied with cable Management arms and rails to rack mount the servers 14 Warranty & Support At least 3 years warranty. NBD Support for part replacement. The warranty will count from the date of installation. Page 5 of 16

6 (b) Specifications, specific to individual server types Additional Technical Specifications of 1U Server (S-1U) Quantity: 34 S NO Component Description 1 SSD s 8 X 960GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) 60,000 or Higher IOPS Random Write (100% Span) 15,000 or Higher IOPS 0.5DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging, and end-to-end Data Protection 2 Chassis Server Chassis should support up to 8 Hard Drives of Redundant Power Supply 4 Form Factor 1U Redundant Power Supply 500W or higher. The power supply modules shall be hot swappable. Additional Technical Specifications of 2U Server (S-2U) Quantity: 60 SI NO Component Description 1 Hard Disk 12 X 8TB Enterprise Hard Disks, 7200RPM, 3.5", 12Gbps Hot swappable 2 NVMe SSD 1 X 800GB Sequential Read up to 2,600 MB/s Sequential Write up to 1,000 MB/s Random 4KB Read up to 430,000 IOPS Random 4KB Write up to 50,000 IOPS Minimum Endurance 3 DWPD PCIe* 3x4,NVMe* 3 Chassis should support a minimum of 12 Hard Drives of Redundant Power Supply 5 Form Factor 2U Redundant Power Supply 800W or higher. The power supply modules shall be hot swappable. Page 6 of 16

7 Additional Technical Specifications of 2U Server (SC-2U) Quantity: 6 S NO Component Description 1 SSDs 8 X 960GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) 60,000 or higher IOPS Random Write (100% Span) 15,000 or higher IOPS 0.5DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging, and end-to-end Data Protection 2 SSDs 4 X 200GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) 60,000 or higher IOPS Random Write (100% Span) 15,000 or higher IOPS 10DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging, and End-to-End Data Protection 3 4 NVMe SSD NVMe SSD 1 X 400GB Sequential Read up to 2,600 MB/s Sequential Write up to 1,000 MB/s Random 4KB Read up to 430,000 IOPS Random 4KB Write up to 50,000 IOPS 10 DWPD PCIe* 3x4,NVMe* 1 X 800GB Sequential Read up to Sequential Write up to Random 4KB Read up to Random 4KB Write up to PCIe* 3x4,NVMe* 2600 MB/s 1000 MB/s 430,000 IOPS 50,000 IOPS 3 DWPD 5 Chassis Server Chassis should support minimum bays. 6 Redundant Power Supply 7 Form Factor 2U Redundant Power Supply 800W or higher. The power supply modules shall be hot swappable. Page 7 of 16

8 2) Bidding formats 2.1 Format for the Technical Bid (a) The Bid must specify the name of the OEM whose servers are offered. (b) The bid must clearly state the OEM model number and part number of the main server offered for each server type (S-1U, S-2U, and SC-2U), and the quantities quoted for each type. The bid must clearly state that the servers are offered with a three year comprehensive warranty, with a commitment for Next Business Day (NBD) part replacement (c) There may be component subsystems obtained by OEM from other sources, such as the RDMA compliant network interface card, NVMe cards, SSDs, and HDDs. All of these must be integrated by the OEM in the offered server. For each of these, the part number given by the OEM, should be provided. These can be listed in a single table in the technical bid, for ease of understanding. If the OEM does not give a separate part number for any such subsystem, the part number of the original manufacturer should be provided. In any case, all such subsystems must be integrated with the servers by OEM only. (d) Technical specifications or data sheets must be supplied for each of the items mentioned in (b) and (c) above. (e) Detailed compliance sheets are provided in section 2.3. These must be filled up properly. Under the compliance column in each sheet, either the word complied should be written wherever that subcomponent or subsystem offered meets the technical specifications. In case there is any deviation, the word deviation should be written under compliance column. A section should be added just fate the filled up compliance sheets, detailing, for each server type, every deviation (citing the corresponding component name) should be mentioned in detail, with explanation as to how and why such deviation does not affect the overall compliance of the offered component/server (f) The Technical Bid must be sealed in a separate envelope as specified in section 1.2(a) 2.2 Format for the Commercial Bid (a) In the bid table, in separate rows for each server type (S-1U, S-2U, and SC-2U), the commercial bid must clearly state the unit price for a server of that type in INR, the number of units offered, taxes and levies, total unit price inclusive of all taxes and levies, and the total amount for the offered quantity. The last row in the table must contain the total bid amount, reflecting the total bid price of all servers in offered quantities. This total amount will be considered for determining the lowest bidder. The commercial bid must specifically reiterate that the prices quoted include warranty support for three years, as required, and as committed in the technical bid (b) The bidder must quote for Post Warranty AMC. Two amounts should be quoted: one for AMC for 4 th year, and another for AMC for 5 th year in seperate sheet. It is to be noted that the prices for optional items are for the Institute to exercise the option, at its sole Page 8 of 16

9 discretion, for continuation of post warranty support in future years. Prices for optional items are NOT considered for price comparison to determine the lowest bidder. 2.3 Tables for submission of technical compliance statement in the technical bid As mentioned in section1 of this part B above, each technical bid is required to provide a compliance statement for each of the three server types offered. Tables given in subsequent pages are to be used for this purpose, with an additional explanation for deviations, if any. Page 9 of 16

10 Compliance Sheet for 1UServer (S-1U) Tender No: S NO Component Description Compliance Server Make Server Model 1 Processor Server should be populated with 2Nos of Intel Xeon E V4 10 Core Processor, 2.20GHz, 25M Cache, 8GT/s QPI 2 Chipset Intel C610 Series Chipset or Higher 3 Memory Populated with 256GB DDR4 ECC RAM (1600MHz or higher) with 8 X 32GB Modules 4 DIMM Slots For a minimum of 512GB RAM, using 32 GB Module 16 x 32GB Modules 5 Memory Property Advanced ECC memory protection, Memory mirroring or Equivalent 6 SSD s 8 X 960GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) or Higher IOPS Random Write (100% Span) or Higher IOPS 0.5DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging and end-to-end Data Protection 7 SD Cards 2 X 8Gb Internal SD Modules, should support redundancy 8 Chassis Server Chassis should support up to 8 Hard Drives of RAID Controller Hardware RAID controller should expose individual disks to BIOS. It should support 8 drives in JBOD mode, with a total throughput of 12Gb/s cumulatively across all ports. RAID controller should support standard Ubuntu16.04 drivers 10 Ethernet Ports 2 * 1 GbE multifunctional network ports Page 10 of 16

11 11 Additional network card 12 Graphics Controller 13 Redundant Power Supply Dual port Mellanox Ethernet Adapter Card ConnectX -4 Lx EN (Copper Support) 10 Gb/s speeds, Low latency RDMA over Converged Ethernet Hardware-based I/O virtualization, RoHS-R6 Minimum 8 MB Memory Redundant Power Supply 500W or higher. The power supply modules shall be hot swappable. 14 Cooling Fans Redundant hot swappable fully populated cooling fans. 15 Form Factor 1U 16 Server Management The server should come with systems management licensed software from the OEM, with Remote Power On and Power Off, Remote KVM, monitoring, alerting, and trouble shooting, should have dedicated 1G port for management. Single console for centralized health monitoring of all servers, should be provided. 17 Rails Must be supplied with cable Management arms and rails to rack mount the servers 18 Warranty & Support At least 3 years warranty. NBD Support for part replacement. The warranty will count from the date of installation. Page 11 of 16

12 Compliance Sheet for 2U Server (S-2U) S NO Component Description Compliance Server Make Server Model 1 Processor 2Nos of Intel Xeon E V4 10 Core Processor, 2.20GHz, 25M Cache, 8GT/s QPI 2 Chipset Intel C610 Series Chipset or higher 3 Memory Populated with 256GB DDR4 ECC RAM (1600MHz or higher) with 8 X 32GB Modules 4 DIMM Slots For a minimum of 512GB RAM, using 16 x 32GB Modules 5 Memory Property Advanced ECC memory protection, memory mirroring or equivalent 6 Hard Disk 12 X 8TB Enterprise Hard Disk 7200RPM, 3.5", 12Gbps Hot swappable 7 SD Cards 2 X 8GB Internal SD Modules, should support redundancy 8 NVMe SSD 1 X 800GB Sequential Read up to 2,600 MB/s Sequential Write up to 1,000 MB/s Random 4KB Read up to 430,000 IOPS Random 4KB Write up to 50,000 IOPS Minimum Endurance 3 DWPD PCIe* 3x4,NVMe* 9 Chassis should support up to 12 Hard Drives of RAID Controller Hardware RAID controller should expose individual disks to BIOS. It should support 12 drives in JBOD mode, with a total throughput of 12Gb/s cumulatively across all ports. RAID controller should support standard Ubuntu16.04 drivers 11 Ethernet Ports 2 * 1 GbE multifunctional in-built network ports 12 Additional Network card Dual port Mellanox Ethernet Adapter Card ConnectX -4 Lx EN (Copper Support) 10 Gb/s speeds, Low latency RDMA over Converged Ethernet Hardware-based I/O virtualization, RoHS-R6 13 Graphics Minimum 8 MB Memory Page 12 of 16

13 Controller 14 Redundant Power Supply Redundant Power Supply 800W or higher. The power supply modules shall be hot swappable. 15 Cooling Fans Redundant hot swappable fully populated cooling fans. 16 Form Factor 2U 17 Remote access Should have dedicated management port for remote access 18 Server Management The server should come with systems management licensed software from the OEM, with Remote Power On and Power Off, Remote KVM, monitoring, alerting, trouble shooting, and should have dedicated 1G port for management. A single console for centralized health monitoring of all servers, should be provided. 19 Rails Must be supplied with cable management arms and rails to rack mount the servers 20 Warranty & Support At least 3 years warranty. NBD Support for part replacement. The warranty will count from the date of installation. Page 13 of 16

14 Compliance Sheet for 2U Server (SC 2U) S NO Component Description Compliance Server Make Server Model 1 Processor Server should be populated with 2Nos of Intel Xeon E V4 10 Core Processor, 2.20GHz, 25M Cache, 8GT/s QPI 2 Chipset Intel C610 Series Chipset or higher 3 Memory Populated with 256GB DDR4 ECC RAM (1600MHz or higher) with 8 X 32GB Modules 4 DIMM Slots For a minimum of 512GB RAM, using 16 x 32GB Modules 5 Memory Property Advanced ECC memory protection, Memory mirroring or equivalent 6 SSD s 8 X 960GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) or Higher IOPS Random Write (100% Span) or Higher IOPS 0.5DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging, and end-to-end Data Protection 7 SSD s 4 X 200GB SSD 2.5" Hot swappable Sequential Read (up to) 550 MB/s Sequential Write (up to) 500 MB/s Random Read (100% Span) 60,000 or Higher IOPS Random Write (100% Span) 15,000 or Higher IOPS 10DWPD Latency - Read 55 µs Latency - Write 66 µs with Enhanced Power Loss Data Protection, High Endurance Technology (HET), Temperature Monitoring and Logging, and End-to-End Data Protection 8 SD Cards 2 X 8Gb Internal SD Modules, should support redundancy 9 NVMe SSD 1 X 400GB Sequential Read up to Sequential Write up to Page 14 of 16 2,600 MB/s 1,000 MB/s

15 10 NVMe SSD Random 4KB Read up to Random 4KB Write up to PCIe* 3x4,NVMe* 430,000 IOPS 50,000 IOPS 10 DWPD 1 X 800GB Sequential Read up to 2600 MB/s Sequential Write up to 1000 MB/s Random 4KB Read up to 430,000 IOPS Random 4KB Write up to 50,000 IOPS 3 DWPD PCIe* 3x4,NVMe* 11 Chassis Server Chassis should support minimum bays. 12 RAID Controller Hardware RAID controller should expose individual disks to BIOS. It should support 12 drives in JBOD mode, with a total throughput of 12Gb/s cumulatively across all ports. RAID controller should support standard Ubuntu16.04 drivers 13 Ethernet Ports 2 * 1 GbE multifunctional network ports 14 Additional network card 15 Graphics Controller 16 Redundant Power Supply Dual port Mellanox Ethernet Adapter Card ConnectX -4 Lx EN (Copper Support) 10 Gb/s speeds, Low latency RDMA over Converged Ethernet Hardware-based I/O virtualization, RoHS-R6 Minimum 8 MB Memory Redundant Power Supply 800W or higher. The power supply modules shall be hot swappable. 17 Cooling Fans Redundant hot swappable fully populated cooling fans. 18 Form Factor 2U 19 Server Management The server should come with systems management licensed software from the OEM, with Remote Power On and Power Off, Remote KVM, monitoring, alerting, trouble shooting; and should have dedicated 1G port for management. Single console for centralized health monitoring of all servers, should be provided. 20 Rails Must be supplied with cable management arms and rails to rack mount the servers 21 Warranty & Support At least 3 years warranty. NBD Support for part replacement. The warranty will count from the date of installation. Page 15 of 16

16 Page 16 of 16

Quotations invited. 2. The supplied hardware should have 5 years comprehensive onsite warranty (24 x 7 call logging) from OEM directly.

Quotations invited. 2. The supplied hardware should have 5 years comprehensive onsite warranty (24 x 7 call logging) from OEM directly. Enquiry No: IITK/ME/mkdas/2016/01 May 04, 2016 Quotations invited Sealed quotations are invited for the purchase of an HPC cluster with the specification outlined below. Technical as well as the commercial

More information

Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai 36

Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai 36 Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai 36 Dr. V V S D Ratna Kumar Annabattula & Dr. Manoj Pandey Phone :044-2257 4719 Project Coordinators Fax :044-2257 4652

More information

GLOBAL TENDER NOTICE NO.: 05/ Last date of receipt of the sealed quotations: Upto 3 P.M. of

GLOBAL TENDER NOTICE NO.: 05/ Last date of receipt of the sealed quotations: Upto 3 P.M. of Institute of Physics (An autonomous Research Institute of Dept. of Atomic Energy, Govt. of India) P.O: Sainik School, Bhubaneswar, Orissa- 751 005, India GLOBAL TENDER NOTICE NO.: 05/2010-2011 Last date

More information

Ref : IT/GOV/ th July Tender for Procurement of Blade Enclosure, Server & Storage

Ref : IT/GOV/ th July Tender for Procurement of Blade Enclosure, Server & Storage Ref : IT/GOV/1295 29 th July 2009 Tender for Procurement of Blade Enclosure, Server & Storage WBIDC is inviting bids for procurement of severs and server related hardware and software as per Annexure I.

More information

Indian Institute of Engineering Science and Technology, Shibpur Howrah Advt. No. DE/D(AA)/16/71 dated 16/12/2016 TENDER

Indian Institute of Engineering Science and Technology, Shibpur Howrah Advt. No. DE/D(AA)/16/71 dated 16/12/2016 TENDER Indian Institute of Engineering Science and Technology, Shibpur Howrah 711 103 Advt. No. DE/D(AA)/16/71 dated 16/12/2016 TENDER The Ramanujan Central Library, Indian Institute of Engineering Science and

More information

ODISHA GRAMYA BANK Information Technology Department Head Office, Gandamunda, P.O.-Khandagiri, Bhubaneswar

ODISHA GRAMYA BANK Information Technology Department Head Office, Gandamunda, P.O.-Khandagiri, Bhubaneswar ODISHA GRAMYA BANK Information Technology Department Head Office, Gandamunda, P.O.-Khandagiri, Bhubaneswar RFP Ref. No. OGB/RFP/ITD/HARDWARE/002/2018-19, Amendment_1 Date: 04-05-2018 AMENDMENT_1: REQUEST

More information

Security Section Indian Institute of Technology Kanpur

Security Section Indian Institute of Technology Kanpur Notice inviting tenders for supply, installation, testing and commissioning of Central Storage for CCTV surveillance equipment at IIT Kanpur Security Section Indian Institute of Technology Kanpur भ रत

More information

The bidder should be willing to arrange for a demonstration of equipment offered at free of cost on

The bidder should be willing to arrange for a demonstration of equipment offered at free of cost on INDIAN INSTITUTE OF TECHNOLOGY TIRUPATI RENIGUNTA ROAD, TIRUPATI- 517 506 Date: 26.04.2018 Public Tender No.IITT/Comp/09/2017-18/08 Due date extended up to 21.05.2018 at 15.30 hours Name of supply: Supply

More information

INSTRUCTIONS TO BIDDERS

INSTRUCTIONS TO BIDDERS INSTRUCTIONS TO BIDDERS 1. This document set contains the following: a) Terms and conditions of the Tender - Pages 2 & 3 b) Details of the Firm offering this Quote - Page 4 c) Technical Compliance & Quotation

More information

(A premier Public Sector Bank) Information Technology Division Head Office, Mangalore. Corrigendum 2. Tender No. 01 / dated

(A premier Public Sector Bank) Information Technology Division Head Office, Mangalore. Corrigendum 2. Tender No. 01 / dated (A premier Public Sector Bank) Information Technology Division Head Office, Mangalore Corrigendum Tender No. 01 /015-16 dated 1.05.015 Supply and Installation of Hardware for up gradation of Southern Grid

More information

ENQUIRY NO.: IIT/ECE/ENQ/GCF/1/ Date: 26/07/2017 INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

ENQUIRY NO.: IIT/ECE/ENQ/GCF/1/ Date: 26/07/2017 INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT TENDER ENQUIRY FORM INDIAN INSTITUTE OF TECHNOLOGY Kharagpur - 721302 Department: ELECTRONICS AND ELECTRICAL COMMUNICATION ENQUIRY NO.: IIT/ECE/ENQ/GCF/1/2017-18 Date: 26/07/2017 INVITATION FOR TENDER

More information

PART-I (B) (TECHNICAL SPECIFICATIONS & COMPLIANCE SHEET) Supply and installation of High Performance Computing System

PART-I (B) (TECHNICAL SPECIFICATIONS & COMPLIANCE SHEET) Supply and installation of High Performance Computing System INSTITUTE FOR PLASMA RESEARCH (An Autonomous Institute of Department of Atomic Energy, Government of India) Near Indira Bridge; Bhat; Gandhinagar-382428; India PART-I (B) (TECHNICAL SPECIFICATIONS & COMPLIANCE

More information

Institute of Physics (An autonomous Research Institute of Dept. of Atomic Energy, Govt. of India) P.O: Sainik School, Bhubaneswar, Orissa ,

Institute of Physics (An autonomous Research Institute of Dept. of Atomic Energy, Govt. of India) P.O: Sainik School, Bhubaneswar, Orissa , NOTE 1. LAST DATE OF RECEIPT OF SEALED QUOTATIONS : EXTENDED TILL 3 PM OF 03.01.2011 2. COMMERCIAL TERM AND CONDITIONS IS MODIFIED 3. TECHNICAL SPECIFICATION FOR BACKUP DEVICE FOR SERVER IS MODIFIED 4.

More information

Subject: Supply and Installation of Workstation for high performance computing.

Subject: Supply and Installation of Workstation for high performance computing. NOTICE INVITING TENDER Subject: Supply and Installation of Workstation for high performance computing. Indian Institute of Technology (Indian School of Mines), Dhanbad invites quotations for the following

More information

NOTICE INVITING TENDER (NIT) SEALED QUOTATIONS FOR SUPPLY, INSTALLATION AND MAINTENANCE OF THREE (3) LAPTOPS at Head Office, Kolkata

NOTICE INVITING TENDER (NIT) SEALED QUOTATIONS FOR SUPPLY, INSTALLATION AND MAINTENANCE OF THREE (3) LAPTOPS at Head Office, Kolkata Ref: HO/DIT/Laptop-Proc-NIT/111 Date: 08.08.2018 NOTICE INVITING TENDER (NIT) SEALED QUOTATIONS FOR SUPPLY, INSTALLATION AND MAINTENANCE OF THREE (3) LAPTOPS at Head Office, Kolkata Allahabad Bank intends

More information

Cisco HyperFlex HX220c M4 Node

Cisco HyperFlex HX220c M4 Node Data Sheet Cisco HyperFlex HX220c M4 Node A New Generation of Hyperconverged Systems To keep pace with the market, you need systems that support rapid, agile development processes. Cisco HyperFlex Systems

More information

CORRIGENDUM / AMENDMENT-1 TO REQUEST FOR PROPOSAL FOR REPLACEMENT OF OLD INTEL SERVERS

CORRIGENDUM / AMENDMENT-1 TO REQUEST FOR PROPOSAL FOR REPLACEMENT OF OLD INTEL SERVERS CORRIGENDUM / AMENDMENT-1 Dated: 25 Sep 2017 With reference to the query received from vendors (bidders), following are the amendments to the RFP Reference No. IT-07/2017-18 dated 08/09/2017 RFP DOCUMENT

More information

Dutch-Bangla Bank Limited

Dutch-Bangla Bank Limited Dutch-Bangla Bank Limited IT Operation Division, Head Office Rupayan Z.R. Plaza, 4 th Floor House No # 46, Road No # 9A Dhanmondi R/A, Dhaka-1209 Ref: DBBL/100/017/2019/011 January 06, 2019 Tender Schedule

More information

Subject: Request for proposal for a high-performance computing cluster

Subject: Request for proposal for a high-performance computing cluster Ref. No.: SSCU/GPR/T/2017-79 2 May 2017 Subject: Request for proposal for a high-performance computing cluster Dear Madam/Sir, I wish to purchase a high-performance computing (HPC) cluster comprising of

More information

Tender Dossier. Tender Title: Supply with notebook computers, servers and other IT equipment to RIT Kosovo. Reference Number: RITKOSOVOIT01/2016

Tender Dossier. Tender Title: Supply with notebook computers, servers and other IT equipment to RIT Kosovo. Reference Number: RITKOSOVOIT01/2016 Tender Dossier Tender Title: Supply with notebook computers, servers and other IT equipment to RIT Kosovo Reference Number: RITKOSOVOIT01/2016 Publication Date: 14.06.2016 Tender requirements: 1. Letter

More information

SCHOOL OF PHYSICAL, CHEMICAL AND APPLIED SCIENCES

SCHOOL OF PHYSICAL, CHEMICAL AND APPLIED SCIENCES PONDICHERRY DEPARTMENT UNIVERSITY OF PHYSICS SCHOOL OF PHYSICAL, CHEMICAL AND APPLIED SCIENCES QUOTATION INVITATION FOR THE PURCHASE OF PROCESSOR SERVER Ref: DST Project "Solitons and Modulational Systems"

More information

PROCUREMENT OF GOODS UNDER NATIONAL SHOPPING PROCEDURES

PROCUREMENT OF GOODS UNDER NATIONAL SHOPPING PROCEDURES PROCUREMENT OF GOODS UNDER NATIONAL SHOPPING PROCEDURES INVITATION FOR QUOTATIONS FOR SUPPLY OF GOODS UNDER NATIONAL SHOPPING PROCEDURES 7 th September 2012 IIFCL invites sealed bids from eligible bidders

More information

IDBI Bank Limited Corrigendum to the RFP For Procurement of Treasury PCs RFP ref. no: IDBI/PCELL/RFP/ /017 dated : 30-Oct-2015

IDBI Bank Limited Corrigendum to the RFP For Procurement of Treasury PCs RFP ref. no: IDBI/PCELL/RFP/ /017 dated : 30-Oct-2015 RFP Page Section / Clause/Para 1 6 Document Control Sheet 2 6 Document Control Sheet Existing clause Schedule for Receipt of Bids: Date 23/11/2015 Time 16:00 hours Schedule for Opening of Technical Bids

More information

REQUEST FOR PROPOSAL FOR PROCUREMENT OF

REQUEST FOR PROPOSAL FOR PROCUREMENT OF REQUEST FOR PROPOSAL FOR PROCUREMENT OF Upgrade of department RFP No.: SBI/GITC/ATM/2018-19/481 : 18/05/2018 Corrigendum II dated 30/05/2018 to Ref: SBI/GITC/ATM/2018-19/481 : 18/05/2018 State Bank of

More information

NATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI INVITATION FOR QUOTATION. TEQIP-III/2017/NITT/Shopping/44

NATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI INVITATION FOR QUOTATION. TEQIP-III/2017/NITT/Shopping/44 Under Technical Education Quality Improvement Programme Phase-III of Government of India Phone 9444170638 Fax 91-(0)431-2500133 Internet www.nitt.edu NATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI-620

More information

American University of Madaba Information Technology Center Digital Signage General Information

American University of Madaba Information Technology Center Digital Signage General Information General Information Objective Of This Rfp: This RFP (Request for Proposal) is issued as a request for the supply and installation of campus digital information display system for the American University

More information

Red Hat Ceph Storage and Samsung NVMe SSDs for intensive workloads

Red Hat Ceph Storage and Samsung NVMe SSDs for intensive workloads Red Hat Ceph Storage and Samsung NVMe SSDs for intensive workloads Power emerging OpenStack use cases with high-performance Samsung/ Red Hat Ceph reference architecture Optimize storage cluster performance

More information

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Data Sheet Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Fast and Flexible Hyperconverged Systems You need systems that can adapt to match the speed of your business. Cisco HyperFlex Systems

More information

Representation of the interested Bidders / vendors. Form no. T2 (TECHNICAL MINIMUM SPECIFICATIONS)

Representation of the interested Bidders / vendors. Form no. T2 (TECHNICAL MINIMUM SPECIFICATIONS) Sr. no. Clause no./page No. Item & Specification in the tender Bidder / Vendor s representation Response to the Bidders Page No.12 1 Chassis: 5U Rack Mountable or Higher Please consider Minimum 2U Rack

More information

Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco UCS C200 M2 High-Density Rack-Mount Server Cisco UCS C200 M2 High-Density Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total cost

More information

PROVISION, INSTALLATION, COMMISIONING & DEPLOYMENT OF BLADE SERVERS WITH CHASSIS

PROVISION, INSTALLATION, COMMISIONING & DEPLOYMENT OF BLADE SERVERS WITH CHASSIS Bidding Document PROVISION, INSTALLATION, COMMISIONING & DEPLOYMENT OF BLADE SERVERS WITH CHASSIS Last Date for Submission: Tender Opening Date: 11 th May, 2018 at 03.00 P.M. 11 th May, 2018 at 03.30 P.M.

More information

Cisco UCS B460 M4 Blade Server

Cisco UCS B460 M4 Blade Server Data Sheet Cisco UCS B460 M4 Blade Server Product Overview The new Cisco UCS B460 M4 Blade Server uses the power of the latest Intel Xeon processor E7 v3 product family to add new levels of performance

More information

भ रत य प द य ग क स स थ न प लक क ड. Indian Institute of Technology Palakkad अहललआ एक क त क म पस, क ज़ हहप र

भ रत य प द य ग क स स थ न प लक क ड. Indian Institute of Technology Palakkad अहललआ एक क त क म पस, क ज़ हहप र भ रत य प द य ग क स स थ न प लक क ड Indian Institute of Technology Palakkad अहललआ एक क त क म पस, क ज़ हहप र Ahalia Integrated Campus, Kozhipara प लक क ड- 678557 Palakkad 678 557 द रभ षस ख य / Phone no:04923

More information

Virtual Environment For Yemen Mobile

Virtual Environment For Yemen Mobile Virtual Environment For Yemen Mobile 1- Bidders Qualification: Any bidder could consider himself as a qualified bidder who has the right to participate at the bidding activity if he submits the required

More information

Tender for Purchase of One Number of Chassis & One Number of Blade Server for Permanent Campus of the Institute at Okhla Phase-III, New Delhi

Tender for Purchase of One Number of Chassis & One Number of Blade Server for Permanent Campus of the Institute at Okhla Phase-III, New Delhi Tender for Purchase of One Number of Chassis & One Number of Blade Server for Permanent Campus of the Institute at Okhla Phase-III, New Delhi-110020 (Tender no. IIITD/S&P/14/2015-16) 1 INVITIATION FOR

More information

Department of Mechanical Engineering Indian Institute of Technology Madras Chennai

Department of Mechanical Engineering Indian Institute of Technology Madras Chennai Department of Mechanical Engineering Indian Institute of Technology Madras Chennai 600 036 Coordinator: Head of the Department, Department of Mechanical Engineering Phone: 044 2257 4650; Fax: 044 2257

More information

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Data Sheet Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes Fast and Flexible Hyperconverged Systems You need systems that can adapt to match the speed of your business. Cisco HyperFlex Systems

More information

(A premier Public Sector Bank) Information Technology Division Head Office-Mangalore. Corrigendum 1 dated

(A premier Public Sector Bank) Information Technology Division Head Office-Mangalore. Corrigendum 1 dated (A premier Public Sector Bank) Information Technology Division Head Office-Mangalore. Corrigendum 1 dated 14.09.2017 No. 05/2017-18 dated 24.08.2017 for Empanelment, Supply & Installation of All-In-One

More information

Altos T310 F3 Specifications

Altos T310 F3 Specifications Product overview The Altos T310 F3 delivers proactive management tools matched by best priceperformance technology ideal for SMB and branch office operations. This singlesocket tower server features an

More information

Pre-Bid Queries for NIT No. RECPDCL/TECH/SERVER-GED/e-Tender/ /186 Dated:

Pre-Bid Queries for NIT No. RECPDCL/TECH/SERVER-GED/e-Tender/ /186 Dated: S. No. Vendor Item 1 HTPGT Pre Qualifying criteria 20/3 Page No. / Clause No. Parameter Sucessful Projects execution 2 HTPGT EMD 3 EMD Amount 3 4 Technical Specifications as per RFP Queries / Modifications

More information

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server Cisco UCS C210 M2 General-Purpose Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total

More information

(Reaccredited with A Grade by the NAAC) RE-TENDER NOTICE. Advt. No. PU/R/RUSA Fund/Equipment Purchase-1/ Date:

(Reaccredited with A Grade by the NAAC) RE-TENDER NOTICE. Advt. No. PU/R/RUSA Fund/Equipment Purchase-1/ Date: Phone: 0427-2345766 Fax: 0427-2345124 PERIYAR UNIVERSITY (Reaccredited with A Grade by the NAAC) PERIYAR PALKALAI NAGAR SALEM 636 011. RE-TENDER NOTICE Advt. No. PU/R/RUSA Fund/Equipment Purchase-1/139-2018

More information

SIOBIINNOVATION AND INCUBATION CENTRE

SIOBIINNOVATION AND INCUBATION CENTRE SIOBIINNOVATION AND INCUBATION CENTRE To Ref No: IIT/SIIC/Mole/Server/BV/03-11-2014 (Revised) Subject: INVITATION FOR QUOTATIONS FOR SUPPLY OF SERVERS, SCANNER AND WORKSTATIONS. Sealed Quotations along

More information

Qualifying Minimum Requirements

Qualifying Minimum Requirements REQUEST FOR PROPOSAL FOR SUPPLY & INSTALLATION OF DESKTOP General Scope of Work: Supply & installation of DESKTOP in the following location. Locations of Installation: ISI kolkata, 203 B.T. Road, Kolkata

More information

INVITATION FOR BIDS For a Nutanix Hyper-Converged Platform (CIP# AHW1801)

INVITATION FOR BIDS For a Nutanix Hyper-Converged Platform (CIP# AHW1801) INVITATION FOR BIDS For a Nutanix Hyper-Converged Platform (CIP# AHW1801) BID SUBMITTAL DATE, TIME, & LOCATION: December 27, 2016 @ 2:00 PM Mount Pleasant Waterworks Operations Center 1619 Rifle Range

More information

should be able to scale to additional pair controllers with 128 GB Cache across Controllers." replacement. With memory of >= 64 GB

should be able to scale to additional pair controllers with 128 GB Cache across Controllers. replacement. With memory of >= 64 GB Existing Storage Technical Specification for 100TB To Be Read AS Item Specification Comments Controllers Dual Active-Active controllers. The system Please read the Specifications as " Dual Active-Active

More information

ClearPath Forward Libra 8480 / 8490

ClearPath Forward Libra 8480 / 8490 ClearPath Forward Libra 8480 / 8490 Product Information Sheet ClearPath Forward Libra 8480 / 8490 Premium Performance MCP Processing Highest performance levels of ClearPath MCP application processing and

More information

WEST BENGAL UNIVERSITY OF TECHNOLOGY TENDER FORM. Notice No:: CSE/FO/2013/4

WEST BENGAL UNIVERSITY OF TECHNOLOGY TENDER FORM. Notice No:: CSE/FO/2013/4 1. Server(1) 2. Server Rack(1) WEST BENGAL UNIVERSITY OF TECHNOLOGY TENDER FORM Notice No:: CSE/FO/2013/4 Date of Issue July 02, 2013 Tender Price: Rs. 200/- D.D. No. for the Tender Price: Address: Tele-Fax

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30 INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/30 27-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

SHORT QUOTATION NOTICE TU/11-24/Pur/Qtn/ /2697-A. dated:

SHORT QUOTATION NOTICE TU/11-24/Pur/Qtn/ /2697-A. dated: SHORT QUOTATION NOTICE TU/11-24/Pur/Qtn/2017-18/2697-A. dated: 21.09.2017 Sealed quotations are invited from reputed manufacturers/authorized dealers/vendors for supply, installation & commissioning etc.

More information

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty

Intel Xeon E v4, Windows Server 2016 Standard, 16GB Memory, 1TB SAS Hard Drive and a 3 Year Warranty pe_r430_11598_b Datasheet Check its price: Click Here Overview delivers peak 2-socket performance for HPC, web tech and infrastructure scale-out. R430 provides Intel Xeon processor E5-2600 v4 product family

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions A comparative analysis with PowerEdge R510 and PERC H700 Global Solutions Engineering Dell Product

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 15 Storage Server

More information

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter , on page External Features, on page Serviceable Component Locations, on page Summary of Server Features, on page The server is orderable in different versions, each with a different front panel/drive-backplane

More information

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments. The IBM System x3500 M4 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30 INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/30 29-Aug-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

Ref : IT/GOV/ th October Tender for Procurement of Blade Enclosure, Server & Storage

Ref : IT/GOV/ th October Tender for Procurement of Blade Enclosure, Server & Storage Ref : IT/GOV/2557 30 th October 2009 Tender for Procurement of Blade Enclosure, Server & Storage In cancellation of our earlier tender no IT/GOV/1295 dated 29 th July 2009, WBIDC is inviting bids for procurement

More information

1. Servers 4 nos. 2. Storage array 1 no.

1. Servers 4 nos. 2. Storage array 1 no. 1/AMC/PC-Peripherals/ 2016-17/Res. Annexure I 1. Servers 4 nos. Dell Power edge 2850 DELL Power Edge 2850 rack mountable Intel Xeon @ 2.8 GHz 2 x 2MB L2/ Dual Channel SCSI controller/ 4GB @300 Mhz ECC

More information

1 Page No. 20, 21 & 22 Form factor. This should be read as 1U/2U Rack Mountable

1 Page No. 20, 21 & 22 Form factor. This should be read as 1U/2U Rack Mountable Karnataka State Natural Disaster Monitoring Centre (Affiliated to Dept. of Science & Technology, Govt. of Karnataka) Pre-bid meeting held on 22.12.2009 Corrigendum RACK SERVERS, SAN Storage, TAPE library,

More information

Exactly as much as you need.

Exactly as much as you need. Exactly as much as you need. Get IT All with PRIMERGY RX300 S6 & PRIMERGY RX200 S6 1 Copyright 2011 FUJITSU Agenda 1. Get IT All: The Offer 2. Dynamic Infrastructures 3. PRIMERGY Portfolio Overview 4.

More information

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks enabling easy collaboration

More information

INVITATION FOR QUOTATION. TEQIP-II/2015/KL1G17/Shopping/152

INVITATION FOR QUOTATION. TEQIP-II/2015/KL1G17/Shopping/152 INVITATION FOR QUOTATION TEQIP-II/2015/KL1G17/Shopping/152 07-Jan-2015 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for

More information

Cisco UCS C24 M3 Server

Cisco UCS C24 M3 Server Data Sheet Cisco UCS C24 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking

More information

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini White Paper Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini February 2015 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 9 Contents

More information

Tender for Supply, Installation, Testing and Commissioning of Computational Systems

Tender for Supply, Installation, Testing and Commissioning of Computational Systems FINAL CONSOLIDATED CLARIFICATIONS IN TENDER No. NITRR/CENTRAL STORE/CCC/OT/207/488 DATED 0/06/207 LAST DATE AND TIME FOR SUBMISSION OF BIDS HAS BEEN EXTENDED UPTO 4 th JULY 207 UPTO 3:00 P.M. LAST DATE

More information

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Cisco UCS C210 M1 General-Purpose Rack-Mount Server Cisco UCS C210 M1 General-Purpose Rack-Mount Server Product Overview Cisco UCS C-Series Rack-Mount Servers extend unified computing innovations to an industry-standard form factor to help reduce total

More information

GW2000h w/gw175h/q F1 specifications

GW2000h w/gw175h/q F1 specifications Product overview The Gateway GW2000h w/ GW175h/q F1 maximizes computing power and thermal control with up to four hot-pluggable nodes in a space-saving 2U form factor. Offering first-class performance,

More information

Cisco Connected Safety and Security UCS C220

Cisco Connected Safety and Security UCS C220 Data Sheet Cisco Connected Safety and Security UCS Platform Series The Cisco Connected Safety and Security (CSS) Unified Computing System (UCS ) Platform Series offers you performance and density for deploying

More information

SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U

SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER S.No. Features Qualifying Minimum Requirements No. of Storage 1 Units 2 Make Offered 3 Model Offered 4 Rack mount 5 Processor 6 Memory

More information

Cisco UCS B230 M2 Blade Server

Cisco UCS B230 M2 Blade Server Data Sheet Cisco UCS B230 M2 Blade Server Product Overview The Cisco UCS B230 M2 Blade Server is one of the industry s highest-density two-socket blade server platforms. It is a critical new building block

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs. , on page 1 External Features, on page 2 Serviceable Component Locations, on page 6 Summary of Server Features, on page 9 The server is orderable in different versions, each with a different front panel/drive-backplane

More information

Cisco HyperFlex HX220c Edge M5

Cisco HyperFlex HX220c Edge M5 Data Sheet Cisco HyperFlex HX220c Edge M5 Hyperconvergence engineered on the fifth-generation Cisco UCS platform Rich digital experiences need always-on, local, high-performance computing that is close

More information

Tender Document. PROCUREMENT OF Servers & Firewall

Tender Document. PROCUREMENT OF Servers & Firewall Tender Document PROCUREMENT OF Servers & Firewall Quaid-e-Azam Thermal Power (Pvt.) Limited 1 st Floor, 7/C-1, Gulberg-III, Lahore Phone No.: 042-35750936-8 Fax No.: 042-3570939 TORS FOR PR0CUREMENT OF

More information

ANNEXURE II - PRICE BID -- Envelope No. 2. Name of Company: Name OF The Item & Specification Offered By Vendor. Total. Total. Sr. No.

ANNEXURE II - PRICE BID -- Envelope No. 2. Name of Company: Name OF The Item & Specification Offered By Vendor. Total. Total. Sr. No. ANNEXURE II - PRICE BID -- Envelope. 2 Name of Company: Price. (Inclusive all s 1 All IN ONE Computer Core i7- Processor, 4GB - DDR4 RAM, 500 GB 7200 RPM SATA HDD, Onboard Graphics, DVD+/- RW Optical Disk

More information

Cisco UCS B200 M3 Blade Server

Cisco UCS B200 M3 Blade Server Data Sheet Cisco UCS B200 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C- Series Rack Servers with networking and storage

More information

Capacity driven storage server. Capacity driven storage server

Capacity driven storage server. Capacity driven storage server Capacity driven storage server Be ready for the era of big data? ASUS, as always, make servers in keeping with the market trend and deliver superior performance. To meet up with the big data demand, the

More information

TENDER DOCUMENT. Procurement of Server (One) and Storage (SAN with 50 TB usable Capacity) for National Cultural Audiovisual Archives Project

TENDER DOCUMENT. Procurement of Server (One) and Storage (SAN with 50 TB usable Capacity) for National Cultural Audiovisual Archives Project TENDER DOCUMENT Procurement of Server (One) and Storage (SAN with 50 TB usable Capacity) for National Cultural Audiovisual Archives Project (File No. 17/09/2015-SD/CIL) March, 2015 Indira Gandhi National

More information

HP ProLiant DL360 G7 Server - Overview

HP ProLiant DL360 G7 Server - Overview Menu Hewlett Packard Enterprise Support Center Search Notifications Help Settings HP ProLiant DL360 G7 Server - Overview Product description What's new Product features Software overview Important links

More information

UCO BANK DEPARTMENT OF INFORMATION TECHNOLOGY

UCO BANK DEPARTMENT OF INFORMATION TECHNOLOGY UCO BANK DEPARTMENT OF INFORMATION TECHNOLOGY Request for Proposal (RFP) for Supply, Installation & Maintenance of Laptops, Thin Clients, Line Printers, Dot Matrix Printers and Flatbed Scanners on rate

More information

Mekong River Commission

Mekong River Commission Mekong River Commission P.O. Box 6101, 184 Fa Ngoum Road, Unit 18, Ban Sithane Neua, Sikhottabong District, Vientiane 01000, Lao PDR Telephone: (856-21) 263 263. Facsimile: (856-21) 263 264 No. RFQ17-141

More information

Cisco UCS B440 M1High-Performance Blade Server

Cisco UCS B440 M1High-Performance Blade Server Cisco UCS B440 M1 High-Performance Blade Server Product Overview The Cisco UCS B440 M1 High-Performance Blade Server delivers the performance and reliability to power compute-intensive, enterprise-critical

More information

Oracle Database Appliance X6-2L

Oracle Database Appliance X6-2L Oracle Database Appliance X6-2L The Oracle Database Appliance saves time and money by simplifying deployment, maintenance, and support of database solutions for organizations of every size. Optimized for

More information

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP:

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP: Vendor must indicate at what level its proposed solution will the College s requirements as delineated in the referenced sections of the RFP: 2.3 Solution Vision Requirement 2.3 Solution Vision CCAC will

More information

Deadline for bid submissions: 9:00 a.m. CST, Friday, August 31, INTRODUCTION

Deadline for bid submissions: 9:00 a.m. CST, Friday, August 31, INTRODUCTION August 1, 2018 Deadline for bid submissions: 9:00 a.m. CST, Friday, August 31, 2018. INTRODUCTION Colby Community College will replace an existing data Storage Area Network (SAN) with a new one that has

More information

Cisco MCS 7815-I2 Unified CallManager Appliance

Cisco MCS 7815-I2 Unified CallManager Appliance Data Sheet Cisco MCS 7815-I2 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Sugon TC6600 blade server

Sugon TC6600 blade server Sugon TC6600 blade server The converged-architecture blade server The TC6600 is a new generation, multi-node and high density blade server with shared power, cooling, networking and management infrastructure

More information

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Altos R320 F3 Specifications. Product overview. Product views. Internal view Product overview The Altos R320 F3 single-socket 1U rack server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities effectively handle SMB

More information

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini White Paper Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini June 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 9 Contents

More information

Supply, Installation & Commissioning of CPU

Supply, Installation & Commissioning of CPU Intelligent Communication Systems India Ltd. (ICSIL) Information Technology Division Request for Quotation For Supply, Installation & Commissioning of CPU For a Department of Govt. of NCT Delhi RFQ Reference

More information

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6

2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 1 of 6 :: Seite 1 von 6 :: Datenblatt zum Produkt Cisco HW ONLY MCS 7825-I4 mit DC# 479326 :: Cisco MCS 7825-I4 Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed

More information

Cisco MCS 7815-I1 Unified CallManager Appliance

Cisco MCS 7815-I1 Unified CallManager Appliance Data Sheet Cisco MCS 7815-I1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

SSD Architecture Considerations for a Spectrum of Enterprise Applications. Alan Fitzgerald, VP and CTO SMART Modular Technologies

SSD Architecture Considerations for a Spectrum of Enterprise Applications. Alan Fitzgerald, VP and CTO SMART Modular Technologies SSD Architecture Considerations for a Spectrum of Enterprise Applications Alan Fitzgerald, VP and CTO SMART Modular Technologies Introduction Today s SSD delivers form-fit-function compatible solid-state

More information

Hyper-converged storage for Oracle RAC based on NVMe SSDs and standard x86 servers

Hyper-converged storage for Oracle RAC based on NVMe SSDs and standard x86 servers Hyper-converged storage for Oracle RAC based on NVMe SSDs and standard x86 servers White Paper rev. 2016-05-18 2015-2016 FlashGrid Inc. 1 www.flashgrid.io Abstract Oracle Real Application Clusters (RAC)

More information

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management Storage Server Features and Components Overview, page 1 Cisco UCS S3260 Storage Management Operations, page 9 Disk Sharing for High Availability, page 10 Storage Enclosure Operations, page 17 Sas Expander

More information

Dutch-Bangla Bank Limited

Dutch-Bangla Bank Limited Dutch-Bangla Bank Limited IT Operation Division, Head Office Rupayan Z.R. Plaza, 4 th Floor House No # 46, Road No # 9A Dhanmondi R/A, Dhaka-1209 Ref: DBBL/100/017/2019/010 January 06, 2019 Tender Schedule

More information

CORRIGENDUM NOTICE - No- 1 with respect to e-tender Notice No. TW-IT/OT/07/

CORRIGENDUM NOTICE - No- 1 with respect to e-tender Notice No. TW-IT/OT/07/ CORRIGENDUM NOTICE - No- 1 with respect to e-tender Notice No. TW-IT/OT/07/2016-17 The following changes have been made due to some administrative reason. Last date & time of submission of bidding document

More information

INVITATION FOR QUOTATION. TEQIP-II/2017/CH2G01/Shopping/126

INVITATION FOR QUOTATION. TEQIP-II/2017/CH2G01/Shopping/126 INVITATION FOR QUOTATION TEQIP-II/2017/CH2G01/Shopping/126 03-Mar-2017 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information