1 Insight Management WBEM Providers 0.0 for Microsoft log Messages Part Number: Published: September 04 Edition:

2 Copyright 00, 04 Hewlett-Packard Development Company, L.P Confidential computer software. Valid license from required for possession, use or copying. Consistent with FAR. and., Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. shall not be liable for technical or editorial errors or omissions contained herein. Acknowledgments AMD is a trademark of Advanced Micro Devices, Inc. Intel is a trademark of Intel Corporation in the United States and other countries. Java is a registered trademark of Oracle Corporation and/or its affiliates. Microsoft and are U.S. registered trademarks of Microsoft Corporation. Warranty will replace defective delivery media for a period of 90 days from the date of purchase. This warranty applies to all Insight Management products.

3 Contents Glossary...4 Introduction...5 Related Documents Indication to log Mapping Sample Indication and Log Message Suggested Log Scraping Method List of Insight Provider Indications... 8 Support and other resources...9 Information to collect before contacting...9 How to contact...9 Security bulletin and alert policy for non- owned software components...9 Subscription service...9 Registering for software technical support and update service...9 How to use your software technical support and update...0 authorized resellers...0 Related information...0 Documents...0 Websites...0 Typographic conventions... 9 Documentation feedback... Contents

4 Glossary Table Acronyms Terms CIM CIMOM COM DLL DMTF OS TC WBEM Definition Common Information Model CIM Object Manager Component Object Model Dynamic Link Library Distributed Management Task Force Operating System Technical Committee Web-Based Enterprise Management 4 Glossary

5 Introduction This document contains a list of the log messages generated by the Insight Management WBEM Providers for Server 008 and Server 0. Each alert indication from the \root\q namespace conforming to the query SELECT * FROM _AlertIndication will be logged to the System Log. Each threshold indication from the \root\q namespace conforming to the query SELECT * FROM _ThresholdIndication will also be logged to the System Log. Figure Indication class diagram 5

6 Related Documents The purpose of this document is to show all indications and the associated event log messages that would be logged to the System Log. The document titled Insight Management WBEM Providers Microsoft Data sheet available at documents all indications and lists the properties delivered by each indication. 6 Related Documents

7 4 Indication to log Mapping The CIM_AlertIndication.ID and CIM_AlertIndication.ProviderName properties are unique for each type of alert indication within the system. The ID and ProviderName properties are used to map to specific messages logged to the System Log. The same applies for the CIM_ThresholdIndication.ID and CIM_ThresholdIndication.ProviderName. 7

8 5 Sample Indication and Log Message Here is a sample of a Log message from an indication with a of and an of 6. Figure Log message expanded from above: Cooling redundancy has been lost. (Cooling Redundancy Set ) User Action Check the fan configuration and check the of the cooling redundancy. Ensure the system is being cooled adequately. Add or replace fans if necessary. WBEM Indication Properties AlertingElementFormat: 0x (CIMObjectPath) AlertingManagedElement: "\\ARSENAL\root\Q:_WinCoolingRedundancySet.InstanceID="Q:_WinCoolingRedundancySet:"" AlertType: 5 0x5 (Device Alert) : "Cooling redundancy has been lost. (Cooling Redundancy Set )" Category: 0x7 (System Cooling) ID: "6" ImpactedDomain: 4 0x4 (System) IndicationIdentifier: "{00B6B4-CE5-4E6A-AEF-CD8F9F9EE}" IndicationTime: " " NetworkAddresses[0]: "9.68.." OSType: 77 0x4D (Microsoft Server Bit) OSVersion: " " PerceivedSeverity: 4 0x4 (Minor) ProbableCause: 88 0x58 (Loss of Redundancy) ProbableCause: "Cooling Redundancy has been Lost" ProviderName: " Cooling" ProviderVersion: "9.0" RecommendedActions[0]: "Check the fan configuration and check the of the cooling redundancy. Ensure the system is being cooled adequately. Add or replace fans if necessary." : "Cooling redundancy lost" SystemCreationClassName: "_WinComputerSystem" SystemFirmwareVersion[0]: " " SystemFirmwareVersion[]: " " SystemGUID: " " 8 Sample Indication and Log Message

9 SystemModel: "ProLiant DL80 G5" SystemName: "arsenal" SystemProductID: " " SystemSerialNumber: "XXX45678" TIME_CREATED: xc88ab690e5504e 9

10 6 Suggested Log Scraping Method The suggested method to perform Log scraping of actionable events is to use the and of the log message to determine the specific type of event that occurred. It is not recommended to parse the event log message text to determine the event type that occurred. 0 Suggested Log Scraping Method

11 7 List of Insight Provider Indications The following table documents the list of indications and corresponding Log messages for version 9. of the Insight Management WBEM Providers. Table Insight Provider Indications for Version 9. (full) Cooling Fan removed A fan has been removed. (%s) Cooling Fan inserted A fan has been inserted. (%s) Cooling Fan failed A fan has failed. (%s) 5475 Cooling 4 Fan repaired A fan has been repaired. The fan is now operating properly. (%s) Cooling 5 Cooling redundancy reduced A fault tolerant fan is no longer providing cooling for a cooling redundancy set. (%s) Cooling 6 Cooling redundancy lost Cooling redundancy has been lost. (%s) Cooling 7 Cooling redundancy gained A fault tolerant fan has been added to a cooling redundancy set. (%s) Cooling 8 Cooling redundancy restored Cooling redundancy for the system has been restored. (%s) Cooling 9 Fan Degraded A fan has Degraded. (%s) CPU Threshold CPU critical threshold exceeded The Average CPU utilization critical threshold has exceeded for CPU:(%s). CPU Threshold 5474 CPU Threshold CPU warning threshold exceeded The Average CPU utilization warning threshold has exceeded for CPU:(%s). CPU Threshold Disk Threshold Disk critical threshold exceeded The Disk utilization critical threshold has exceeded for Disk:(%s). Disk Threshold 5474

12 Table Insight Provider Indications for Version 9. (continued) (full) Disk Threshold Disk warning threshold exceeded The Disk utilization warning threshold has exceeded for Disk:(%s). Disk Threshold Ethernet provider fatal error An Ethernet provider encountered an unrecoverable error. Ethernet 547 Ethernet Network interface lost connectivity A network interface has failed. An Ethernet adapter's changed from OK to Error, or an Ethernet team's Error from another state. Ethernet 5474 Ethernet Network connectivity restored A failed network interface was restored. An Ethernet port's changed from an Error state to a non-error state. Ethernet Ethernet 4 Ethernet team's redundancy decreased An Ethernet team's redundancy has decreased. A team member has failed or degraded state. Ethernet Ethernet 5 Ethernet team lost redundancy An Ethernet team's redundancy Redundancy Lost. All members of an Ethernet team, except one, are failed. Ethernet Ethernet 6 Ethernet team redundancy increased An Ethernet team's redundancy has increased. A team member recovered from a failed or degraded state. Ethernet Ethernet 7 Ethernet team member added to team. A new team member has been added to an Ethernet team via the Network Configuration Utility (NCU). This Ethernet List of Insight Provider Indications

13 Table Insight Provider Indications for Version 9. (continued) (full) is an optional indication that can be disabled via the Ethernet Provider settings. Ethernet 8 Ethernet team member dropped from team A team member was dropped from the team via the Network Configuration Utility (NCU). This is an optional indication that can be disabled via the Ethernet Provider settings. Ethernet Ethernet 9 Ethernet team member reported role change An Ethernet Team member's role has changed. This is an optional indication that can be disabled via the Ethernet Provider settings. Ethernet Ethernet 0 An Ethernet team member's has changed. This is an optional Ethernet team indication that can member be disabled via reported the Ethernet change Provider settings. Ethernet Ethernet New network interface available A new network interface is available. An Ethernet adapter has been added or an Ethernet team or VLAN has been created. This is an optional indication that can be disabled via the Ethernet Provider settings. Ethernet Ethernet Network interface no longer available A network interface is no longer available. An Ethernet adapter was removed or an Ethernet team or VLAN was removed via the Network Configuration Utility (NCU). Ethernet

14 Table Insight Provider Indications for Version 9. (continued) (full) Ethernet Ethernet team reported change in number of active members The number of active adapters in an Ethernet team has changed. This is an optional indication that can be disabled via the Ethernet Provider settings. Ethernet Ethernet 4 Provider cannot access data source The event provider encountered a non-fatal error. Some information may not be available. Ethernet Ethernet 5 Ethernet team redundancy Fully Redundant An Ethernet team's redundancy Fully Redundant. An Ethernet team member changed from Error or Degraded to OK. Ethernet Fibre Channel FC HBA port state Unknown A fibre channel port has changed to an unknown. Fibre Channel Fibre Channel FC HBA port OK This fibre channel HBA port has returned to a of OK. Fibre Channel Fibre Channel FC HBA port in offine state A fibre channel port has changed to a state of Offline. Fibre Channel Fibre Channel 4 FC HBA port in bypass state A fibre channel port has changed to a state of bypassed. Fibre Channel Fibre Channel 5 FC port in diagnostic state A fibre channel HBA port is operating in a diagnostic state. Fibre Channel Fibre Channel 6 FC HBA port in link down state A fibre channel HBA port has a state of link down. Fibre Channel Fibre Channel 7 FC HBA port Failed A fibre channel port has changed to a failed. Fibre Channel Fibre Channel 8 FC HBA port in loopback state A fibre channel port has changed Fibre Channel List of Insight Provider Indications

15 Table Insight Provider Indications for Version 9. (continued) (full) to a loop back state. Memory Memory module has failed or is predicted to fail A memory module has failed or is predicted to fail. (%s) Memory 547 Memory Memory board error A memory board has an error. (%s) Memory 5474 Memory Advanced Memory Protection degraded The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. (%s) Memory 5475 Memory 4 Advanced Memory Protection redundancy is fully operational The Advanced Memory Protection (AMP) system is operating normally in the targeted configuration. If redundancy was previously degraded, redundancy has been restored. (%s) Memory MgmtProc Management Processor Reset initiated Management Processor Reset has been initiated from WBEM Providers. MgmtProc MgmtProc The Management Processor has been reset successfully The Management Processor has been reset successfully and is available now. MgmtProc MgmtProc The Management Processor reset failed The Management Processor has not reset successfully and may not be operational. MgmtProc 5475 POST POST errors occurred Power-On-Self-Test (POST) errors System

16 Table Insight Provider Indications for Version 9. (continued) (full) occurred during the last system startup. Power Power supply removed A power supply has been removed. (%s) Power Power supply inserted A power supply has been inserted. (%s) Power Power supply failed A power supply has failed. (%s) Power 4 Power supply repaired A power supply has been repaired. (%s) Power 5 Power redundancy reduced A fault tolerant power supply is no longer providing power for a power redundancy set. (%s) Power 6 Power redundancy lost Power redundancy has been lost. (%s) Power 7 Power redundancy gained A fault tolerant power supply has been added to a power redundancy set. (%s) Power 8 Power redundancy restored Power redundancy for the system has been restored. (%s) Power 9 Power supply failed - input power lost A power supply has failed input power lost. (%s) Processor Processor failed A processor has failed. Processor Processor Processor deconfigured A processor has been disabled by ROM Based Setup (RBSU). Processor Recovery ASR reboot occurred The system has rebooted from a Automatic Server Recovery (ASR) event. System List of Insight Provider Indications

17 Table Insight Provider Indications for Version 9. (continued) (full) Recovery Thermal reboot occurred The system has rebooted from a thermal shutdown event. System 5474 SAS HBA OK A SAS/SATA HBA changed from non-ok to OK. SAS SAS HBA Error A SAS/SATA HBA Error. SAS 5474 SAS 0 Logical Drive OK A logical drive changed from non-ok to OK. SAS SAS 0 Logical drive Error A logical drive Error. SAS SAS 0 Logical drive degraded state A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost. SAS SAS 0 Physical Drive Status is now OK A physical drive changed from non-ok to OK. SAS SAS 0 Error A physical drive Error. SAS SAS 0 rebuilding A physical drive Rebuilding. Data is now being rebuilt onto this drive from the RAID set. SAS SAS 04 predictive failure A physical drive Predictive Failure. SAS SAS 0 Power Supply Non-Redundant Enclosure Power Subsystem has non-redundant. SAS SAS 0 Redundant power supply OK Enclosure Power Supply has SAS

18 Table Insight Provider Indications for Version 9. (continued) (full) Fully Redundant. SAS 0 Power supply Redundant Degraded Enclosure Power Supply Degraded Redundancy. SAS SAS 04 Fan OK Enclosure Fan changed from a non-ok state to OK. SAS SAS 05 Fan Degraded Enclosure Fan Degraded. An enclosure has detected there may a problem with one or more of the fans. SAS SAS 06 Fan Error Enclosure Fan Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. SAS SAS 07 sensor OK Enclosure sensor changed from non-ok to OK. SAS SAS 08 sensor Warning Condition Enclosure sensor Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. SAS List of Insight Provider Indications

19 Table Insight Provider Indications for Version 9. (continued) (full) SAS 09 sensor Critical Enclosure sensor Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. SAS SAS Predictive Failure. Due to Solid State wear out a physical drive Predictive Failure. SAS 578 SAS Degraded. Indicates that the physical drive was not able to be authenticated and could not be validated to be a genuine hard drive. SAS SATA 600 New Disk Drive found A new disk drive was detected. SATA SATA 60 Disk Drive unknown A Disk Drive has Unknown. SATA SATA 60 Disk Drive OK A Disk Drive has OK. SATA SATA 60 Disk Drive error A Disk Drive has 'Error'. SATA SATA 604 Disk Drive degraded A Disk Drive has 'Degraded'. SATA SATA 605 Predictive Failure. A physical drive Predictive Failure. Drive is functioning nominally but predicting a failure in the near future. SATA

20 Table Insight Provider Indications for Version 9. (continued) (full) SATA 6 Disk Drive Missing A Disk Drive disappeared from system. SATA SCSI SCSI device unknown A SCSI device Unknown. SCSI SCSI SCSI HBA OK This SCSI HBA changed from non-ok to OK. SCSI SCSI SCSI HBA error A SCSI HBA has Error. SCSI 5475 SCSI 4 OK A SCSI physical drive changed from non-ok to OK. SCSI SCSI 5 Error A SCSI physical drive has a of Error. SCSI SCSI 6 missing was OK A SCSI physical drive with a of OK that was located in the system has been removed. SCSI SCSI 7 missing was Error A SCSI physical drive with a of Error that was located in the system has been removed. SCSI SCSI 8 SCSI physical drive predictive failure A SCSI physical drive is now set to Predictive Failure. SCSI SCSI 9 missing was Predictive Failure A SCSI physical drive with a of Predictive Failure that was located in the system has been removed. SCSI SCSI 0 offline A SCSI physical drive is offline and can no longer return data. No further is available. SCSI SCSI missing was offline A SCSI physical drive that was located in the SCSI List of Insight Provider Indications

21 Table Insight Provider Indications for Version 9. (continued) (full) system and had a of offline has been removed. SCSI 0 Power Supply Non-Redundant Enclosure Power Supply non-redundant. SCSI SCSI 0 Redundant power supply OK Enclosure Power Supply has Fully Redundant. SCSI SCSI 0 Power supply Redundant Degraded Enclosure Power Supply Degraded Redundancy. SCSI SCSI 04 Fan OK The storage enclosure fan subsystem is operating properly. SCSI SCSI 05 Fan Degraded A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure cool. SCSI SCSI 06 Fan Error A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool. SCSI SCSI 07 sensor OK Enclosure sensor changed from non-ok to OK. SCSI SCSI 08 sensor Warning Condition Enclosure sensor Status Warning Condition. This indicates the enclosure temperature is above normal, otherwise SCSI

22 Table Insight Provider Indications for Version 9. (continued) (full) enclosure is still operating normally. SCSI 09 sensor Critical Enclosure sensor Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. SCSI Controller OK A Smart controller has changed from non-ok to OK Controller Error A Smart controller has Error Controller redundancy state set to Active A Smart controller redundancy state has changed from Standby to Active Controller redundancy lost A Smart controller has detected that redundancy has been lost due to failure or loss of communication with partner controller Controller redundancy restored A Smart controller has detected that redundancy has been restored and can communicate with partner controller Controller battery OK A Smart controller Battery changed from non-ok to OK List of Insight Provider Indications

23 Table Insight Provider Indications for Version 9. (continued) (full) 7 Controller Battery Status set to Not fully Charged. A Smart controller Battery Not Fully Charged Controller battery Failed A Smart controller battery Failed Controller cache OK A Smart controller Cache changed from non-ok to OK controller cache temporarily disabled A Smart controller Cache Temporarily Disabled. This may be caused by a rebuild or configuration change. Normal operation will return after background operations have completed controller cache permanently disabled A Smart controller Cache Permanently Disabled. The controller has detected a problem with the cache and has disabled the cache permanently controller cache not configured A Smart controller Cache not configured. This may be caused by a configuration change Logical drive OK A logical drive changed from a non-ok state to OK

24 Table Insight Provider Indications for Version 9. (continued) (full) 0 Logical drive error A logical drive Error Logical drive in degraded state A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost Logical drive in degraded state - multipath failure A logical drive is in a degraded state. Multipath support is Lost. Either cable is removed or not configured Logical drive in transforming from Unencrypted to Encrypted state. A logical drive transforming from Unencrypted to Encrypted Logical drive in Rapid Parity Initialization in progress state. A logical drive Rapid Parity Initialization in progress Logical drive in Rapid Parity Initialization Queued state. A logical drive Rapid Parity Initialization Queued Physical Drive OK A physical drive changed from a non-ok state to OK Error A physical drive Error is now rebuilding. A physical drive Rebuilding. Data is now being rebuilt onto this drive from the RAID set A physical drive List of Insight Provider Indications

25 Table Insight Provider Indications for Version 9. (continued) (full) Predictive Failure. Predictive Failure. Secure Erase. A Physical Drive is Currently Offline but operational, Secure Erase is in Progress. Once the Secure Erase is Complete, please reinsert the same disk or new disk for the disk to be operational Physical Drive Online A physical drive is in Online state. After Secure Erase Operation Power Supply Non-Redundant Enclosure Power Subsystem has non-redundant Redundant power supply OK Enclosure Power Supply has Fully Redundant Power supply Redundant Degraded Enclosure Power Supply Degraded Redundancy Fan OK Enclosure Fan changed from a non-ok state to OK Fan Degraded Enclosure Fan Degraded. An enclosure has detected there may a problem with one or more of the fans Fan Error Enclosure Fan Failure. An enclosure has detected a failure

26 Table Insight Provider Indications for Version 9. (continued) (full) in the fan subsystem and there is insufficient fan capability to ensure normal operation. 07 sensor OK Enclosure sensor changed from non-ok to OK sensor Warning Condition Enclosure sensor Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally sensor Critical Enclosure sensor Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs Predictive Failure Due to Solid State wear out a physical drive Predictive Failure Degraded. Indicates that the physical drive was not able to be authenticated and could not be validated to be a List of Insight Provider Indications

27 Table Insight Provider Indications for Version 9. (continued) (full) genuine hard drive. Tape 50 Tape drive unknown A tape drive has Unknown. Tape Tape 50 Tape drive OK A tape drive has OK. Tape Tape 50 Tape drive degraded A tape drive has 'Degraded'. Tape Tape 504 Tape drive error A tape drive has 'Failed'. Tape Tape 505 New tape drive found A new tape drive was detected. Tape Tape 506 Tape drive offline A tape drive has 'offline'. Tape Tape 507 Tape drive missing was OK A tape drive with a OK been removed. Tape Tape 508 Tape drive missing was 'Failed' A tape drive with a 'Failed' has been removed. Tape Tape 509 Tape drive missing was 'Offline' A tape drive with a 'Offline' has been removed. Tape Tape 50 Tape drive missing was 'Degraded' A tape drive with a 'Degraded' been removed. Tape Tape 5 Tape drive cleaning required Tape drive heads need cleaning. Tape Tape 5 Cleaning tape replacement required A fully used cleaning tape has been detected. Tape critical threshold exceeded detected A temperature sensor has detected that the temperature has exceeded the normal operating range. (%s) Threshold exceeded A temperature sensor has detected that the

28 Table Insight Provider Indications for Version 9. (continued) (full) condition recovery temperature has returned to a normal operating range. (%s) Caution threshold exceeded detected A temperature sensor has detected that the temperature has exceeded the normal operating range. (%s) Test Test This is an Informational Test. Test Test Test This is a Warning Test. Test Test Test This is an Error Test Test 5475 WBEM WBEM Providers started Insight Management WBEM Providers have started. System List of Insight Provider Indications

29 8 Support and other resources Information to collect before contacting Be sure to have the following information available before you contact : Software product name Hardware product model number Operating system type and version Applicable error message Third-party hardware or software Technical support registration number (if applicable) How to contact Use the following methods to contact technical support: In the United States, see the Customer Service / Contact United States website for contact options: In the United States, call INVENT ( ) to contact by telephone. This service is available 4 hours a day, 7 days a week. For continuous quality improvement, conversations might be recorded or monitored. In other locations, see the Contact Worldwide website for contact options: Security bulletin and alert policy for non- owned software components Open source software (such as OpenSSL) or third-party software (such as Java) are sometimes included in products. discloses that the non- owned software components listed in the Insight Management end user license agreement (EULA) are included with Insight Management. The EULA is included with the Insight Management Installer on Insight Management DVD #. addresses security bulletins for the software components listed in the EULA with the same level of support afforded products. is committed to reducing security defects and helping you mitigate the risks associated with security defects when they do occur. When a security defect is found, has a well defined process that culminates with the publication of a security bulletin. The security bulletin provides you with a high level description of the problem and explains how to mitigate the security defect. Subscription service recommends that you register your product at the Subscriber's Choice for Business website: After registering, you will receive notification of product enhancements, new driver versions, firmware updates, and other product resources. Registering for software technical support and update service Insight Management includes one year of 4 x 7 Software Technical Support and Update Service. This service provides access to technical resources for assistance in resolving software implementation or operations problems. Information to collect before contacting 9

30 The service also provides access to software updates and reference manuals in electronic form as they are made available from. With this service, Insight Management customers benefit from expedited problem resolution as well as proactive notification and delivery of software updates. For more information about this service, see the following website: Registration for this service takes place following online redemption of the license certificate. How to use your software technical support and update As releases updates to software, the latest versions of the software and documentation are made available to you. The Software Updates and Licensing portal gives you access to software, documentation, and license updates for products on your software support agreement. You can access this portal from the Support Center: After creating your profile and linking your support agreements to your profile, see the Software Updates and Licensing portal at to obtain software, documentation, and license updates. authorized resellers For the name of the nearest authorized reseller, see the following sources: In the United States, see the U.S. service locator website: In other locations, see the Contact worldwide website: Related information Documents Websites Insight Management WBEM Providers User Guide available at: Insight Management WBEM Providers 9. for Microsoft Hardware Support Matrix available at: Insight Management WBEM Providers Microsoft Data sheets available at: Insight Management WBEM Providers SNMP Data Migration Guide available at: Insight Management WBEM Providers Release Notes available at: Insight Management WBEM Provider documents are available at the following location: 0 Support and other resources

31 Typographic conventions This document uses the following typographical conventions: Book title Command Computer output Ctrl+x or Ctrl-x ENVIRONMENT VARIABLE Key Term User input Replaceable [ ] { }... WARNING CAUTION IMPORTANT NOTE TIP The title of a book. On the web, this can be a hyperlink to the book itself. A command name or command phrase, for example ls -a. Information displayed by the computer. A key sequence that indicates you must hold down the keyboard key labeled Ctrl while you press the letter x. The name of an environment variable, for example, PATH. The name of a keyboard key. Return and Enter both refer to the same key. A term or phrase that is defined in the body text of the document, not in a glossary. Indicates commands and text that you type exactly as shown. The name of a placeholder that you replace with an actual value. In command syntax statements, these characters enclose optional content. In command syntax statements, these characters enclose required content. The character that separates items in a linear list of choices. Indicates that the preceding element can be repeated one or more times. An alert that calls attention to important information that, if not understood or followed, results in personal injury. An alert that calls attention to important information that, if not understood or followed, results in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information. An alert that contains additional or supplementary information. An alert that provides helpful information. Typographic conventions

32 9 Documentation feedback is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback

HPE Insight Management WBEM Providers for Microsoft Windows Eventlog Messages

HPE Insight Management WBEM Providers for Microsoft Windows Eventlog Messages E Insight Management WBEM s 0.60 for Microsoft log Messages Part Number: 866479-00 Published: October 06 Edition: Copyright 00, 06 Hewlett Packard Enterprise Development LP The information contained herein

More information

HP Insight Control for Microsoft System Center Installation Guide

HP Insight Control for Microsoft System Center Installation Guide HP Insight Control for Microsoft System Center Installation Guide Abstract This guide describes installing HP Insight Control for Microsoft System Center. This guide is intended for use by system integrators

More information

HPE Insight Management Agents Installation Guide

HPE Insight Management Agents Installation Guide HPE Insight Management Agents 10.60 Installation Guide Abstract This guide provides information about the Hewlett-Packard Enterprice Insight Management Agents software Installation and Configuration procedures.

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version

More information

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide HP Part Number: Part Number 530778-003 Published: May 2010 (Fourth Edition) Notices Copyright 2009, 2010 Hewlett-Packard Development

More information

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April

More information

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi and vsphere. HP Part Number: 616896-409 Published: September

More information

Marvell BIOS Utility User Guide

Marvell BIOS Utility User Guide Marvell BIOS Utility User Guide for HPE MicroServer Gen10 Abstract This user guide provides information on how to use the embedded Marvell BIOS Utility to create and manage RAID virtual disks and arrays.

More information

HP SCOM Management Packs User Guide

HP SCOM Management Packs User Guide HP SCOM Management Packs User Guide Abstract This guide describes the HP extensions for Microsoft System Center Operations Manager that are provided as part of HP OneView for Microsoft System Center (formerly

More information

MSA Event Descriptions Reference Guide

MSA Event Descriptions Reference Guide MSA Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported during

More information

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

This provider generates indications of type HP_DeviceIndication. The Provider requires HP WBEM Services for OpenVMS.

This provider generates indications of type HP_DeviceIndication. The Provider requires HP WBEM Services for OpenVMS. EMS Wrapper Provider Provider Overview Description Requirements Release history Web Based Enterprise Management (WBEM) indication provider for wrapping OpenVMS Event Monitoring Services (OpenVMS EMS) events.

More information

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. HP SATA Hard Drives. Overview QuickSpecs Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. The SATA portfolio is categorized into two

More information

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview. Overview HP 6 Port SATA RAID controller provides customers with new levels of fault tolerance for low cost storage solutions using SATA hard drive technologies. Models SATA RAID Controller 372953-B21 DA

More information

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview Overview HP offers a variety of tested, HP-qualified, SMART* capable, SATA Hard Drives offering data integrity and availability in hotpluggable models. HP 3.5" and Small Form Factor (2.5") SATA drives

More information

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. HP SATA Midline drives are designed with economical reliability

More information

HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide

HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide HPE 1/8 G2 Tape Autoloader and MSL Tape Libraries Encryption Kit User Guide Abstract This guide provides information about developing encryption key management processes, configuring the tape autoloader

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P800 is HP's first 16 port serial attached SCSI (SAS) RAID controller with PCI-Express (PCIe). It is the highest performing controller in the SAS portfolio and provides new

More information

HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows)

HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows) HP Intelligent Management Center v7.1 MySQL 5.6 Installation and Configuration Guide (Windows) Abstract This document provides installation and configuration information for MySQL. It includes the procedures

More information

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview Overview Upgrading or replacing your existing server? Migration is now an option! Replicate the server you are replacing using the software, the only product of its kind from a server vendor that provides

More information

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.) Overview The HP Smart SAS Expander Card enhances the Smart Array controller family by allowing support for more then 8 internal hard disk drives on select ProLiant servers when connected to a Smart Array

More information

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring

Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring HP StorageWorks Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring Application Note doc-number Part number: T2558-96338 First edition: June 2009 Legal and notice information

More information

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

QuickSpecs. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview Overview HP offers a variety of tested, HP-qualified, SMART* capable, SATA Hard Drives offering data integrity and availability in hotpluggable models. HP Large Form Factor (3.5-inch) and Small Form Factor

More information

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits Overview

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits Overview Overview HP introduces the next generation of SATA drives that are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. The new SATA portfolio

More information

QuickSpecs HP Insight Rapid Deployment software 6.0

QuickSpecs HP Insight Rapid Deployment software 6.0 Overview HP Insight Rapid Deployment software is a complete deployment solution for ProLiant and Integrity servers. HP Insight Rapid Deployment software automates the process of deploying and provisioning

More information

SUSE Linux Enterprise Server 11 Support Pack 2 Support Notes

SUSE Linux Enterprise Server 11 Support Pack 2 Support Notes SUSE Linux Enterprise Server 11 Support Pack 2 Support Notes for HP Integrity Servers HP Part Number: 5900-0820 Edition: Edition: 2 Copyright 2012 Hewlett-Packard Development Company, L.P. Legal Notices

More information

HP Server Updates Catalog for System Center Configuration Manager 2007 User Guide

HP Server Updates Catalog for System Center Configuration Manager 2007 User Guide HP Server Updates Catalog for System Center Configuration Manager 2007 User Guide HP Part Number: Part Number 615495-001 Published: May 2011 (Second Edition) Notices Copyright 2011 Hewlett-Packard Development

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information

HP StoreVirtual Storage Multi-Site Configuration Guide

HP StoreVirtual Storage Multi-Site Configuration Guide HP StoreVirtual Storage Multi-Site Configuration Guide Abstract This guide contains detailed instructions for designing and implementing the Multi-Site SAN features of the LeftHand OS. The Multi-Site SAN

More information

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview Overview The HP Smart Array P400 Serial Attached SCSI (SAS) controller (SA-P400) provides new levels of performance and reliability for HP servers, through its support of the latest SCSI technology and

More information

NOTE: For additional information regarding the different features of SATA Entry drives please visit the SATA hard drive website:

NOTE: For additional information regarding the different features of SATA Entry drives please visit the SATA hard drive website: QuickSpecs Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. The SATA portfolio is categorized into two

More information

HPE FlexNetwork MSR Router Series

HPE FlexNetwork MSR Router Series HPE FlexNetwork MSR Router Series Comware 7 OAA Configuration Guides Part number: 5998-8789 Software version: CMW710-E0407 Document version: 6W100-20160526 Copyright 2016 Hewlett Packard Enterprise Development

More information

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

HP Intelligent Management Center Remote Site Management User Guide

HP Intelligent Management Center Remote Site Management User Guide HP Intelligent Management Center Remote Site Management User Guide Abstract This book provides overview and procedural information for Remote Site Management, an add-on service module to the Intelligent

More information

HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5

HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5 HPE WBEM Providers for OpenVMS Integrity servers Release Notes Version 2.2-5 January 2016 This release note describes the enhancement, known restrictions, and errors found in the WBEM software and documentation,

More information

QuickSpecs. HPE Smart Array E208i-p SR Gen10 Controller. Overview

QuickSpecs. HPE Smart Array E208i-p SR Gen10 Controller. Overview Overview **For latest information on this product please use HPE Smart Array Gen10 Controllers for HPE ProLiant DL, ML and Apollo Servers ** The, supporting 12Gb/s SAS and PCIe 3.0, is an ideal cost-effective

More information

Provider Overview. Description Requirements. The provider requires HP WBEM Services for HP-UX.

Provider Overview. Description Requirements. The provider requires HP WBEM Services for HP-UX. Provider Overview HP-UX LAN Indication Provider - CIM Indication Provider for Ethernet LAN interfaces The HP-UX LAN Indication Provider delivers indications for events that occur on Ethernet interfaces.

More information

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations Technical Note Revised October 2006 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Configuring the StorageWorks MSA1000 and MSA1500cs for External Boot with NetWare Considerations...3

More information

QuickSpecs. What's New Support for HP software and hardware server support. Models. HP Insight Server Migration software for ProLiant v.3.

QuickSpecs. What's New Support for HP software and hardware server support. Models. HP Insight Server Migration software for ProLiant v.3. Overview NOTE: Effective November 16, 2009, HP Insight Server Migration software for ProLiant offered exclusively as part of HP Insight Control suites. For additional information please visit: http://www.hp.com/go/insightcontrol

More information

HP BladeSystem Matrix Compatibility Chart

HP BladeSystem Matrix Compatibility Chart HP BladeSystem Matrix Compatibility Chart For supported hardware and software, including BladeSystem Matrix firmware set 1.01 Part Number 512185-003 December 2009 (Third Edition) Copyright 2009 Hewlett-Packard

More information

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.5. Overview. Retired

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.5. Overview. Retired Overview ProLiant Essentials Performance Management Pack (PMP) is a software solution that detects, analyzes, and explains hardware bottlenecks on HP ProLiant servers. HP Integrity servers and HP Storage

More information

QuickSpecs. What's New 300GB 6G SAS 15K rpm SFF (2.5in) Enterprise Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives.

QuickSpecs. What's New 300GB 6G SAS 15K rpm SFF (2.5in) Enterprise Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased

More information

QuickSpecs. HPE Smart Array P431 Controller. Overview

QuickSpecs. HPE Smart Array P431 Controller. Overview Overview The is a low profile, PCIe3 x8, 12Gb/s capable Serial Attached SCSI (SAS) RAID controller that provides enterprise class storage performance, increased external scalability, and data protection

More information

HP D6000 Disk Enclosure Direct Connect Cabling Guide

HP D6000 Disk Enclosure Direct Connect Cabling Guide HP D6000 Disk Enclosure Direct Connect Cabling Guide Abstract This document provides cabling examples for when an HP D6000 Disk Enclosure is connected directly to a server. Part Number: 682251-001 September

More information

HPE LTO Ultrium 30750, 15000, 6250, 3000, 1760, and 920 External Tape Drives Start Here

HPE LTO Ultrium 30750, 15000, 6250, 3000, 1760, and 920 External Tape Drives Start Here HPE LTO Ultrium 30750, 15000, 6250, 3000, 1760, and 920 External Tape Drives Start Here Abstract This document describes how to connect a StoreEver LTO Ultrium SAS external tape drive to an external high-density

More information

HP Accelerated iscsi for Multifunction Network Adapters User Guide

HP Accelerated iscsi for Multifunction Network Adapters User Guide HP Accelerated iscsi for Multifunction Network Adapters User Guide Part Number 410538-00J December 2007 (Ninth Edition) Copyright 2006, 2007 Hewlett-Packard Development Company, L.P. The information contained

More information

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide

HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated

More information

При обращении используйте промокод AND-PDF и получите скидку.

При обращении используйте промокод AND-PDF и получите скидку. Overview The is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for specific

More information

ZKLWHýSDSHU. 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH. +3ý 1HW6HUYHUý 0DQDJHPHQW. Executive Summary. A Closer Look

ZKLWHýSDSHU. 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH. +3ý 1HW6HUYHUý 0DQDJHPHQW. Executive Summary. A Closer Look 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH ZKLWHýSDSHU Executive Summary The Hewlett-Packard Pre-Failure Warranty 1 helps you run your business with less downtime. It extends the advantage of

More information

HP Virtual Connect Enterprise Manager

HP Virtual Connect Enterprise Manager HP Virtual Connect Enterprise Manager Data Migration Guide HP Part Number: 487488-001 Published: April 2008, first edition Copyright 2008 Hewlett-Packard Development Company, L.P. Legal Notices Confidential

More information

System Fault Management Administrator s Guide

System Fault Management Administrator s Guide System Fault Management Administrator s Guide HP-UX 11i v1 HP Part Number: 5991-6717 Published: E0612 Copyright 2006 Hewlett-Packard Development Company, L.P Legal Notices The information in this document

More information

HP P2000 G3 MSA System Event Descriptions Reference Guide

HP P2000 G3 MSA System Event Descriptions Reference Guide HP P2000 G3 MSA System Event Descriptions Reference Guide Part number: 591224-006 First edition: February 2013 Legal and notice information Copyright 2013 Hewlett-Packard Development Company, L.P. Confidential

More information

QuickSpecs. HPE Smart Array P204i-b SR Gen10 Controller. Overview

QuickSpecs. HPE Smart Array P204i-b SR Gen10 Controller. Overview Overview Overview The, supporting 12Gb/s SAS and PCIe 3.0, is ideal for maximizing performance while supporting advanced RAID levels with 1 GB flash-backed write cache (FBWC). This controller operates

More information

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

RAID-01 (ciss) B Mass Storage Driver Release Notes

RAID-01 (ciss) B Mass Storage Driver Release Notes RAID-01 (ciss) B.11.31.1705 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HPE product. Part Number: Published:

More information

HPE PSR300-12A & PSR300-12D1

HPE PSR300-12A & PSR300-12D1 HPE PSR300-12A & PSR300-12D1 Power Supplies User Guide 5998-1604s Part number: 5998-1604s Document version: 6PW103-20160405 Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information

More information

HP StoreVirtual Storage Multi-Site Configuration Guide

HP StoreVirtual Storage Multi-Site Configuration Guide HP StoreVirtual Storage Multi-Site Configuration Guide Abstract This guide contains detailed instructions for designing and implementing the Multi-Site SAN features of the LeftHand OS. The Multi-Site SAN

More information

HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide

HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide HPE StoreEver MSL6480 Tape Library CLI Utility Version 1.0 User Guide Abstract This document explains how to install and use the HPE StoreEver MSL6480 Tape Library CLI utility, which provides a non-graphical

More information

QuickSpecs. HP SAS Hard Drives. Overview

QuickSpecs. HP SAS Hard Drives. Overview Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased

More information

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. HP SATA Midline drives are designed with economical reliability

More information

QuickSpecs SmartStart TM Release 6.0

QuickSpecs SmartStart TM Release 6.0 S MARTSTART The ProLiant Essentials Foundation Pack, which includes the SmartStart CD and the Management CD ships standard with every ProLiant ML/DL Server. For more information on SmartStart, visit us

More information

QuickSpecs. What's New New for Smart Array Advanced Pack 2.0: Features are base offering on HP Smart Array P222, P420i, P420, and P421.

QuickSpecs. What's New New for Smart Array Advanced Pack 2.0: Features are base offering on HP Smart Array P222, P420i, P420, and P421. Overview (SAAP) consists of a group of firmware that provides additional and advanced feature functionality within the Smart Array Controllers that requires a license key for activation. These licensed

More information

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired Overview NOTE: HP no longer sells RHEL and SLES on Integrity servers. HP will continue to support RHEL 5 on Integrity servers until Red Hat's end of support life date for RHEL 5 (March 31st, 2017). HP

More information

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service HP Services Technical data The HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service provides the necessary

More information

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased

More information

Intelligent Provisioning 3.00 Release Notes

Intelligent Provisioning 3.00 Release Notes Intelligent Provisioning 3.00 Release Notes Part Number: 881705-001b Published: October 2017 Edition: 3 Copyright 2017 Hewlett Packard Enterprise Development LP Notices The information contained herein

More information

QuickSpecs. HPE SATA Hard Drives. Overview. HPE Hard Disk Drives

QuickSpecs. HPE SATA Hard Drives. Overview. HPE Hard Disk Drives Overview HPE Hard Disk Drives HPE Hard Disk Drives (HDDs) delivers proven performance at industry leading capacities backed by high quality and reliability, preferred choice for many workloads ranging

More information

HP 3PAR OS MU1 Patch 11

HP 3PAR OS MU1 Patch 11 HP 3PAR OS 313 MU1 Patch 11 Release Notes This release notes document is for Patch 11 and intended for HP 3PAR Operating System Software HP Part Number: QL226-98041 Published: December 2014 Edition: 1

More information

QuickSpecs. What's New New 146GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive. HP SCSI Ultra320 Hard Drive Option Kits (Servers) Overview

QuickSpecs. What's New New 146GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive. HP SCSI Ultra320 Hard Drive Option Kits (Servers) Overview Overview A wide variety of rigorously tested, HP-qualified, SMART capable, Ultra320 Hard Drives offering data integrity and availability in hot pluggable and non-pluggable models. HP 15,000 rpm Hard Drives

More information

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here Abstract This document describes how to install a StoreEver LTO Ultrium SAS internal tape drive and is intended for

More information

Intelligent Provisioning 3.10 Release Notes

Intelligent Provisioning 3.10 Release Notes Intelligent Provisioning 3.10 Release Notes Part Number: 881705-002 Published: February 2018 Edition: 1 Copyright 2017, 2018 Hewlett Packard Enterprise Development LP Notices The information contained

More information

HP 9.5mm SATA DVD RW Optical Drive

HP 9.5mm SATA DVD RW Optical Drive Overview The HP SATA optical drives for HP ProLiant servers are offered with an industry-standard SATA interface and are supported on most major operating systems. The DVD RW drive will be capable of reading

More information

HP SATA DVD RW Optical Drives Overview. HP 9.5mm SATA DVD RW Optical Drive

HP SATA DVD RW Optical Drives Overview. HP 9.5mm SATA DVD RW Optical Drive Overview The HP SATA optical drives for HP ProLiant servers are offered with an industry-standard SATA interface and are supported on most major operating systems. The DVD RW drive will be capable of reading

More information

Troubleshooting. User Guide

Troubleshooting. User Guide Troubleshooting User Guide Copyright 2006 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. The information contained herein is subject

More information

Troubleshooting. Document Part Number: December 2005

Troubleshooting. Document Part Number: December 2005 Troubleshooting Document Part Number: 383067-003 December 2005 Contents 1 Quick checklist The computer will not start up..................... 1 2 The computer screen is blank...................... 1 3

More information

QuickSpecs. Model Host Bus Adapter HP H222 Host Bus Adapter B21. HP H222 Host Bus Adapter. Overview

QuickSpecs. Model Host Bus Adapter HP H222 Host Bus Adapter B21. HP H222 Host Bus Adapter. Overview Overview The is a 1X4 external port and 1x4 internal port HBA provides customers with the flexibility and speed they have come to expect from HP. The H222 HBA is ideal for internal and external connectivity

More information

HP ilo 3 Release Notes

HP ilo 3 Release Notes HP ilo 3 Release Notes 1.70 HP Part Number: 616296-401 Published: February 2014 Edition: 1 Copyright 2014 Hewlett-Packard Development Company, L.P Confidential computer software. Valid license from HP

More information

HP 3PAR OS MU3 Patch 17

HP 3PAR OS MU3 Patch 17 HP 3PAR OS 3.2.1 MU3 Patch 17 Release Notes This release notes document is for Patch 17 and intended for HP 3PAR Operating System Software. HP Part Number: QL226-98310 Published: July 2015 Edition: 1 Copyright

More information

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes

HP BladeSystem c-class Virtual Connect Support Utility Version Release Notes HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version

More information

HPE StoreVirtual OS v13.5 Release Notes

HPE StoreVirtual OS v13.5 Release Notes HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4

More information

PowerVault MD3 Storage Array Enterprise % Availability

PowerVault MD3 Storage Array Enterprise % Availability PowerVault MD3 Storage Array Enterprise 99.999% Availability Dell Engineering June 2015 A Dell Technical White Paper THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes

HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes HPE Moonshot ilo Chassis Management Firmware 1.52 Release Notes Part Number: 732171-007 Published: February 2017 Edition: 1 2017 Hewlett Packard Enterprise Development LP Notices The information contained

More information

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview QuickSpecs Overview HP IO Accelerator for ProLiant Servers is a PCIe card-based direct-attach solid state storage technology solution for application performance enhancement. Based on Multi-Level Cell

More information

HP Business Service Management

HP Business Service Management HP Business Service Management Software Version: 9.26 Getting Started With BPM - Best Practices Document Release Date: September 2015 Software Release Date: September 2015 Legal Notices Warranty The only

More information

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information

More information

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD ROM Optical Drive. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD ROM Optical Drive. Overview Overview The HP SATA optical drives for HP ProLiant servers are offered with an industry-standard SATA interface and are supported on most major operating systems. The DVD ROM drive is designed to read

More information

About the HP 830 Series PoE+ Unified Wired-WLAN Switch and HP 10500/ G Unified Wired-WLAN Module

About the HP 830 Series PoE+ Unified Wired-WLAN Switch and HP 10500/ G Unified Wired-WLAN Module About the HP 830 Series Switch and HP 10500/7500 20G Unified Module s Part number: 5998-3903 Software version: 3308P29 (HP 830 Series Switch) 2308P29 (HP 10500/7500 20G Unified Module) Document version:

More information

HP 10500/ G Unified Wired-WLAN Module

HP 10500/ G Unified Wired-WLAN Module HP 10500/7500 20G Unified Wired-WLAN Module Fundamentals Configuration Guide Part number: 5998-3914 Software version: 2308P29 (HP 10500/7500 20G Unified Wired-WLAN Module) Document version: 6W102-20131112

More information

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD RW Optical Drive. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD RW Optical Drive. Overview Overview The HP SATA optical drives for HP ProLiant servers are offered with an industry-standard SATA interface and are supported on most major operating systems. The DVD RW drive will be capable of reading

More information

QuickSpecs. What's New. HP Solid State Drives (SSD) Overview

QuickSpecs. What's New. HP Solid State Drives (SSD) Overview Overview HP s (SSDs) deliver exceptional performance and endurance for customers with applications requiring high random read IOPs performance. Leveraging NAND Flash technology, they support HP ProLiant

More information

HP Online ROM Flash User Guide. July 2004 (Ninth Edition) Part Number

HP Online ROM Flash User Guide. July 2004 (Ninth Edition) Part Number HP Online ROM Flash User Guide July 2004 (Ninth Edition) Part Number 216315-009 Copyright 2000, 2004 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required

More information

HPE 3PAR OS MU5 Patch 49 Release Notes

HPE 3PAR OS MU5 Patch 49 Release Notes HPE 3PAR OS 3.2.1 MU5 Patch 49 Release Notes This release notes document is for Patch 49 and intended for HPE 3PAR Operating System Software + P39. Part Number: QL226-99362a Published: October 2016 Edition:

More information

QuickSpecs. Available Packs and Purchase Information. ProLiant Essentials Vulnerability and Patch Management Pack v2.1. Overview.

QuickSpecs. Available Packs and Purchase Information. ProLiant Essentials Vulnerability and Patch Management Pack v2.1. Overview. Overview Pack (VPM) integrates comprehensive vulnerability assessment and advanced patch management functions for HP and non-hp servers running Windows or Red Hat Linux into HP Systems Insight Manager,

More information

QuickSpecs Microsoft Windows Server 2008

QuickSpecs Microsoft Windows Server 2008 Microsoft Windows Server 2008 is Microsoft's next generation operating system designed to be the most flexible and robust Windows Server operating system to date. Windows Server 2008 provides powerful

More information

HP 3PAR OS MU3 Patch 18 Release Notes

HP 3PAR OS MU3 Patch 18 Release Notes HP 3PAR OS 3.2.1 MU3 Patch 18 Release Notes This release notes document is for Patch 18 and intended for HP 3PAR Operating System Software 3.2.1.292 (MU3). HP Part Number: QL226-98326 Published: August

More information

Guest Management Software V2.0.2 Release Notes

Guest Management Software V2.0.2 Release Notes Guest Management Software V2.0.2 Release Notes Abstract These release notes provide important release-related information for GMS (Guest Management Software) Version 2.0.2. GMS V2.0.2 is MSM software version

More information

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide

HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide HP 3PAR StoreServ Storage VMware ESX Host Persona Migration Guide Abstract This guide is intended to assist customers in successfully migrating their VMware ESX/ESXi hosts on HP 3PAR StoreServ storage

More information