1 DORMA Installation Manual B6L 4P
2 Contents Contents 1 General information Preface Correct use Safety instructions and warnings Other sources of information Disposal Operating principle Scope of delivery Accessories System overview Installation Opening/closing the B6L 4P Installing the B6L 4P The B6L 4P component modules Assignment of readers to input/output modules Putting into operation Installing the batteries in the B6L 4P Reader wiring and adjustment Settings on the readers Address, terminating resistor Bus terminating resistor Settings on the connector board Configuration of relay contacts Wiring of strike, operating current principle Wiring of feedback contacts LAN interface Connecting the supply voltage (110 to 230 V AC) Removing contact guard from back-up battery TP4 base card optical signals Power supply unit status LEDs Maintenance Maintenance and troubleshooting Fuse General information on changing the battery Replacing the back-up battery RS232 service interface Power supply unit Battery replacement Declaration of Conformity Technical data
3 1. General information 1.1 Preface This installation manual is intended to assist you in connecting and putting into operation the B6L 4P. 1.2 Correct use The device is solely intended for use as an access control terminal. The device processes the identification carriers read by connected readers and controls the respective doors according to the authorisation profiles stored in the device via strikes. Use for any other purpose than the one described is notpermitted. 1.3 Safety instructions and warnings This device has been constructed and tested in accordance with all currently applicable technical regulations. All safety features were in proper working order when it left the factory. The user must observe the instructions and warnings given in this installation guide to maintain proper working order and ensure risk-free operation. The device may only be used for the purpose intended by the manufacturer. Installation and assembly of electrical equipment may only be carried out by a qualified electrician. Before opening the unit, always switch off the power supply and check that it is inactive by measuring the current. During installation, please ensure that the requirements laid down in the relevant equipment safety standard for the unit are adhered to since non-compliance could affect the safety of the device. Before switching on, ensure that the connected operating and control voltages do not exceed the permissible values specified in the technical data. This device complies with EN Protection Class I and may only be used if a protective conductor is connected. Make sure that the wall on which the device is to be mounted is able to bear the load. Lead batteries: Batteries may possibly generate inflammable gas. Do not ever expose batteries to naked flames or extreme heat. Do not short-circuit batteries. Do not open batteries under any circumstances. Batteries can explode. Never expose batteries to fire. Batteries of different ages and from different fields of application should not be connected and/or operated together. Dispose of batteries in compliance with statutory provisions. The average service life of the batteries used is about four years if they are used at a temperature of 25 C and charged on a regular basis. Higher operating temperatures reduce the service life. Electromagnetic compatibility: The device is designed for use in residential, business and commercial areas and complies with EN and PCBs can be damaged by static electricity discharge, so suitable precautionary measures such as grounding must be implemented. Drawing no.: 1101G-00-B1 Date: 12/12 V2.00 3
4 1. General information This unit may only be operated when installed. The locking screws on unassigned connection terminals must be screwed in as far as they will go. If a unit failure or malfunction may result in injury to persons or animals, or in damage to works equipment, this must be prevented by implementing additional safety measures, such as limit switches and safety devices. General installation guidelines See Manual 1006G-B0 If you believe that the device can no longer be operated safely, take it out of operation and secure it against accidental use. The information provided in these assembly instructions may be modified without prior notification. All previous versions cease to be valid with the publication of these instructions. The information in these assembly instructions has been compiled to the best of our knowledge and in good faith. DORMA Time + Access GmbH accepts no liability for the correctness and completeness of the details provided. In particular, DORMA Time + Access GmbH cannot accept liability for any consequential damages due to incorrect or incomplete information. The recommendations for installation made in this manual are based on the assumption that prevailing basic conditions are favourable. DORMA Time + Access GmbH accepts no liability for the perfect functioning of the B6L 4P in nonsystem environments. Despite every effort to prevent mistakes, they can never be completely avoided. Therefore, we would be grateful to receive notification of any errors or omissions. DORMA Time + Access GmbH accepts no liability for the information included in this document being free of protected third party rights. DORMA Time + Access GmbH does not provide any licences to its own or to third party patents or other protected rights with this document. It is not permitted to print, reproduce or to pass this manual, or parts thereof, to third parties, other than for your own use, without the approval of DORMA Time + Access GmbH. All rights are reserved. Dorma Time + Access GmbH Postfach Bonn info@dorma-time-access.de Copyright 2013 by Dorma Time + Access GmbH 4
5 1. General information 1.4 Other sources of information Further documents are available on request. General Installation Guidelines Specifications for planning attendance recording and access control systems with our wired components. Planner Manual Examples of cross-system solutions DORMA Allgemeine Installationsrichtlinien Sicherungstechnik Zutrittskontrolle Zeiterfassung Funktionsweise Gelände Außenhaut Innenbereich Systemübersicht Systemlösung Funktionsweise Mechatronik Fluchtweg & TMS Funktionsweise Zeitwirtschaft 1.5 Disposal This device has been manufactured using high-quality materials and components that can be recycled. Information for EU countries This device falls under the European Directive 2002/96 EC and therefore must not be disposed of with household waste. We, the manufacturer, will take back our electric and electronic products and dispose of them for you free of charge. You may also contact your waste disposal company instead. 1.6 Operating principle The B6L 4P is a fully-fledged, stand-alone access control terminal which reads identification carriers held to the connected S6 readers and activates connected strikes via corresponding permission profiles. The B6L 4P is able to control four doors using the basic configuration described here. Eight S6 readers and four lowpower strikes can be connected to the B6L 4P in order to control doors. Two feedback contacts can be configured for each connected door. Readers with a phg_crypt protocol may be used instead of S6 readers based on a DP1 protocol if they are parameterised in a suitable way. It is not possible to use both protocols simultaneously in mixed mode. Two extension kits are available to extend the B6L 4P (see accessories). 1. I/O module extension kit: You can use this extension kit to increase the number of doors to be controlled from four to eight. This allows you to connect a maximum of 16 S6 readers. 2. MUX extension kit: This kit allows the connected S6 readers to be wired in a star configuration. Without this particular kit, the readers can only be wired to a bus connection. The B6L 4P features an integrated emergency power supply which is able to power the device and connected components for at least 30 minutes in the event of a power failure. To ensure the backup power supply lasts at least 30 minutes, a maximum of 16 S6 readers (max. 40 ma per S6 reader) and a maximum of eight low-power closed-circuit current strikes (max. 150 ma/24 V) may be installed and the rechargeable batteries must be fully charged and in perfect condition. 5
6 1. General information 1.7 Scope of delivery A 1x B6L 4P B 1x manual C 3x S8 wall plugs D 3x Spax screws, 4.5 x 45 mm E Cable tie F Battery connection cable A C B 3x 3x D DORMA Installationshandbuch B6L 4P 2x E F 7,5 1.8 Accessories Reader as per price list Door strike (example) Strikes and locking plates as per price list B6L 4P extension kit MUX ( ) B6L 4P extension kit I/O-Modul ( ) 6
7 1. General information 1.9 System overview Connection example: Networked door system - Parameterisation and data exchange via PC (online) MATRIX B6L 4P Ethernet 10/100MBit Recommended cable: Mains lead: NYM-I 3x1,5 (H05VV-R3G1,5) max. 100m max. 100m max. 100m I-Y(ST)Y 3x2x0,8 I-Y(ST)Y 3x2x0,8 I-Y(ST)Y 3x2x0,8 Outside Reader Reader Reader Inside min. 2x0,8 min. 2x0,8 min. 2x0,8 Door contact Door contact Door contact Opening Opening Opening switch switch switch min. 2x0,8 min. 2x0,8 min. 2x0,8 min. 2x1mm² min. 2x1mm² min. 2x1mm² Door opener Door opener Door opener Door 1 Door 2... Door 4 Max. four doors (each with a reader, strike and two feedback contacts) 7
8 2. Installation 2.1 Opening/closing the B6L 4P ST
9 2. Installation 2.2 Installing the B6L 4P A1 A5 A4 A2 A3 1. Take out the base plate (A1) 2. Place the base plate (A1) in its mounting position using a spirit level to ensure it is straight and mark the drill hole positions with a pen. Before drilling, ensure that you will not damage any cables or similar located under the plaster. 3. Fasten the base plate (A1) using suitable mounting accessories. 4. Undo the four hexagonal nuts (A2) and take out the mounting plate (A3) from the casing lower section (A4). 5. Fasten the casing lower section (A4) to the base plate (A1) using the screws (A5). 6. Fasten the mounting plate (A3) into the casing lower section (A4) using the hexagonal nuts (A2). A1 7. To finish off, reconnect the clamp terminal ST309 (page 7, item 5) and the PE plug (page 7, item 6). 9
10 2. Installation 10A L N INPUT 503 Si 2,5 2.3 The B6L 4P component modules Anti-tamper switch TP4 base card Connector board Compartment for rechargeable batteries Power supply unit CH OG BU MA PG OUT BAT Input/output module Cable duct Cable inlet for mains cable 400V Strain relief for mains cable Strain relief Strain relief Kabeleinführung für Netzkabel 10
11 2. Installation 2.4 Assignment of readers to input/output module L N INPUT OUT BAT 10A 503 Si 400V 2,5 CH OG BU MA PG SW102 SW101 ST401 ST402 ST403 ST404 ST405 ST406 ST407 ST408 ST301 ST302 ST303 ST304 ST305 ST306 ST307 ST308 ST309 Door Cards Reader I/O module 1 Out Door relay (operating current strike) I/O module 1 Out Alarm relay I/O module 1 In Door status contact 1 1 ST401 ST301 I/O module 1 In Door opening contact 1 2 ST402 ST ST403 ST ST404 ST ST405 ST ST406 ST ST407 ST ST408 ST308 11
12 10A B6L 4P 3. Putting into operation 3.1 Installing the batteries in the B6L 4P E F OUT BAT CH OG BU MA PG 12
13 3. Putting into operation 3.2 Reader wiring and adjustment 3x2xØ0,8 max. 100m brown green yellow white brown green yellow white L N INPUT OUT BAT 10A 503 Si 400V 2,5 CH OG BU MA PG DP1 phg_crypt Reader 1 Reader 2 - n SW101 SW101 SW101 13
14 3. Putting into operation Settings on the readers Address, terminating resistor Switch Function Bus address Not used Bus terminating resistor Default on off off off off off off off Adjustable Reader 1 on off off off off Reader 2 off on off off off Reader 3 on on off off off Reader 4 off off on off off Reader 5 on off on off off Reader 6 off on on off off Reader 7 on on on off off Reader 8 off off off on off Bus terminating resistor If the reader is the last bus device, the terminating resistors must be switched on Settings on the connector board You can connect either S6 readers with a DP1 protocol or readers with a phg_crypt protocol to the B6L 4P. It is not possible to use both protocols simultaneously in mixed mode. In addition to parameterising the TP4 base card, you also need to change slide switches on the connector board together. 14
15 3. Putting into operation 3.3 Configuration of relay contacts SW102 10A 503 Si 400V 2,5 CH OG BU MA PG SW101 Jumpers in factory default setting The I/O module features eight relays. Each relay has a 4-pin plug connector in front of the output terminal. The relay contacts can be connected separately from one another with two jumpers so that they are isolated (Jumper Position A) or they can be allocated an auxiliary voltage (internal supply; Jumper Position B). OUT BAT You must remember that you may only connect eight low-power strikes with 150 ma power consumption each to ensure a 30-minute emergency power supply can be provided for the whole access control system. L N INPUT Maximum current per relay contact: 1 A. Each relay contact is equipped with a self-resetting thermal fuse. Inductive loads must be provided with freewheeling diodes if a DC power supply is used. When connecting an alternating current, an RC element or a voltage regulative diode (Item no ) must be used in place of a freewheeling diode for interference suppression. 0V 24V Changeover contact (common) Closing contact (normally open) Break contact (normally closed) Jumper Setting A (factory default setting) Relay jumper setting in the case of isolated contacts 0V 24V Changeover contact (common) Closing contact (normally open) Break contact (normally closed) Jumper Setting B - Relay jumper setting in the case of looped-in voltage 15
16 3. Putting into operation SW102 SW101 0V NO NC ST402 ST403 ST404 ST405 ST406 ST407 ST408 ST301 ST302 ST303 ST304 ST305 ST306 ST307 ST308 ST309 min. 2x1mm 2 max. 100m 10A 400V L N INPUT OUT BAT 503 Si 2,5 CH OG BU MA PG 3.4 Wiring of strike, operating current principle Door opener 16
17 3. Putting into operation Door contact L N INPUT 10A 503 Si 400V 2,5 OUT BAT CH OG BU MA PG 3.5 Wiring of feedback contacts Door opening switch (on rear) SW102 SW101 ST401 ST402 ST403 ST404 ST405 ST406 ST407 ST408 ST101 ST102 0V K ST301 0V K ST302 ST305 ST304 ST305 ST306 ST307 ST308 ST309 Door status contact Door opening contact 17
18 3. Putting into operation 3.6 LAN interface A CAT5 cable with RJ45 plug must be provided by the customer. The LAN interface is located on the TP4 base card. The LAN interface complies with Ethernet standard IEEE 802.3u. LAN Warning It is essential that you take care not to move the sliding switch when inserting the LAN connector. 18
19 3. Putting into operation 3.7 Connecting supply voltage (230 V AC) The B6L 4P must be connected when it is not live. T6,3A 400V 503 Si 2,5 N 10A L 3.8 Removing contact guard from back-up battery 503 Si L N INPUT 10A 400V 2,5 OUT BAT CH OG BU MA PG 19
20 3. Putting into operation 3.9 TP4 base card optical signals LED 301 On Meaning System run Hardware and software in operation LED 302 Supply Voltage LED 302 Green Off Red Meaning Input voltage above the minimum permissible voltage Input voltage below the minimum permissible voltage A manual reset has been triggered LED 301 Internal Voltage LED 401 Flashing Meaning Data is being sent or received LED 402 Off Meaning Remote terminal present LED 601 SubBus LED 402 LAN Link LED 601 Meaning On Data is being sent or received LED 401 LAN Rx/Tx 20
21 10A 503 Si 400V 2,5 CH OG BU MA PG B6L 4P 3. Putting into operation 3.10 Power supply unit status LEDs LED L1 Flashes red Lights up red Lights up green LED off Pre-charging Recharging Trickle charge No battery, low battery voltage, battery defective OUT BAT L N INPUT LED L2 Lights up green Lights up orange Lights up red Correct operating status Overload at output Mains supply failure L2 CH OG BU MA PG OUT BAT L1 L N INPUT 21
22 4. Maintenance 4.1. Maintenance and troubleshooting Maintenance on an opened device may be carried out by a qualified person or an electrician only! The unit should be disconnected from the mains by removing the fuse in the mains connection (page 22) before carrying out maintenance or inspection work Fuse If the fuse (SI301 base card) needs to be replaced, there is a spare fuse in the bottom right-hand corner of the basic module. The fuse can be re-ordered by indicating Item no (Littlefuse type , 2 A). The use of other fuses is not permitted. The fuse at the mains input (6.3 A, time-delay) can be re-ordered by indicating Item no If the blade fuse in the battery connection cable is defective (10 A, fast-blow), a new connection cable can be ordered by indicating Item number
23 4. Maintenance General information on changing the battery Lithium back-up battery Lithium back-up battery for power failure-proof buffering of the data stored in RAM. Continuous buffer time: approx. 3 5 years. Type CR2032/3 V, 230 mah, plugged in, service life approx. 10 years. Replacement battery CR2032, Item no.: Changing the battery is permitted when live. To retain the data in the unit when changing the battery, the power supply to the unit must remain switched on. Risk of explosion if the battery is not replaced properly. Dispose of used batteries in accordance with statutory provisions Replacing the back-up battery The battery is inserted into the holder vertically. To change the battery, push the power failure safety lock to the side. The battery can then be easily removed from the holder. The new battery can be pushed into the holder by pushing the safety lock to the side in the same way. Please ensure that the poles are correctly positioned RS232 service interface The enclosed null modem cable can be used to connect the 9-pin D-sub connector to a PC. The supplied RS232/USB converter can be used to connect the service interface via USB RX 7 3 TX GND Casing 23
24 4. Maintenance 4.2 Power supply unit In order to ensure reliable operation in the event of a power failure, the UPS circuit must be checked at regular intervals. To do so, pull out the fuse from the mains connection (see arrow). The LEDs should then react as follows: LED L1 Flashes red Pre-charging OUT BAT LED L2 Lights up red Mains power failure L N INPUT Insert the fuse again. Warning: The batteries should be replaced every four years at the latest. The average service life of four years for the batteries used is based on an operating temperature of 25 C. Higher operating temperatures reduce the servicelife. T6,3A 400V 503 Si 2,5 10A 400V 2,5 CH OG BU MA PG 503 Si N 10A L L2 CH OG BU MA PG OUT BAT L1 L N INPUT 24
25 10A B6L 4P 4. Maintenance 4.3 Battery replacement Remove the connection wires from the battery. Unscrew battery retaining bracket with batteries. Cut through cable ties, remove batteries and dispose of them in an environmentally friendly way. 25
26 10A B6L 4P 4. Maintenance Insert the new batteries into the retaining bracket and fasten the batteries firmly into place on the bracket using the cable ties in the accessories kit Screw retaining bracket into place and plug in the connecting cable. Ensure the polarity symbols are in the right position. You must use DORMA rechargeable batteries to ensure that the device functions correctly. Replacement battery set Item no.: OUT BAT CH OG BU MA PG 26
27 EG Konformitätserklärung EC Declaration of Conformity CE Déclaration de conformité 27
28 5. Technical data Technical data B6L 4P Nominal voltage range 230 V AC, Hz Rated current input 1.35 A Output voltage for reader, door opener 24 V DC ± 5%, maximum load 2.5 A Emergency power back-up 24 V DC ±5%/2 Ah, at 25 C Expected battery life max. four years Replacement battery set Item no Back-up time Max. 30 min. at full load (16 ID card readers and eight DORMA low-power closed-circuit current strikes) Data retention Power failure-proof buffering of data stored in the RAM. Replacement battery CR2032, Item no.: External ID card reader RS485: max. eight ID readers can be connected (16 ID readers with the extension kit) Interfaces Host: Ethernet (10/100 Mbit) Sub-bus: RS485 Anti-tamper monitoring Available Digital outputs Eight relay contacts, isolated or non-isolated, maximum 1 A Digital inputs Eight non-isolated inputs, 24 V, active, low Ambient conditions Operating temperature range: 20 C bis + 50 C Storage temperature range: 20 C bis + 70 C Humidity range: 0 bis 90 %, non-condensing General design EN , Protection Class I Protection rating IP 30 Resistance to interference EN Immunity for industrial environments Resistance to interference EN Emission standard for residential, commercial and light-industrial environments Dimensions (W x H x D) 454 x 439 x 112 mm Casing colour Traffic White, RAL 9016 Weight About 16.5 kg Display 5x LEDs on TP4 basic module 2x LEDs in power supply unit for mains voltage and battery operation 8x relays on output module 8x digital inputs on input module (only visible when the casing is opened) DORMA Time + Access GmbH DORMA GmbH + Co. KG 28 Postfach D Bonn Mainzer Straße D Bonn Tel. +49 (0) 2 28/ Fax +49 (0) 2 28/ Postfach D Ennepetal DORMA Platz 1 D Ennepetal Tel. +49 (0) / Fax +49 (0) /
DORMA. Installation Manual Extension kit I/O module in the B6L 4P
DORMA Installation Manual Extension kit I/O module in the B6L 4P Contents Contents 1 General information......................... 3 1.1 Preface................................. 3 1.2 Correct use.............................
More informationDORMA. Installation Manual B6L WM
DORMA Installation Manual B6L WM Table of Contents Table of Contents 1. General information... 3 1.1 Preface...4 1.2 Correct use...4 1.3 Safety instructions and warnings...4 1.4 Further Source of Information.............
More informationDORMA. Installation Manual MUXD 19" (B6L 19'')
DORMA Installation Manual MUXD 19" (B6L 19'') Table of Contents Table of Contents 1 General Information...4 1.1 Preface...5 1.2 Correct use...5 1.3 Safety instructions and warnings...5 1.4 Further Source
More informationDORMA. Installation Manual M6L / M6R Terminal
DORMA Installation Manual M6L / M6R Terminal Table of Contents Table of Contents 1. General....4 1.1 Preface....5 1.2 Correct use...5 1.3 Safety instructions and warnings....5 1.4 Further Source of Information....6
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationInstallation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:
Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes
More informationPOE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from
POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately
More informationFeatures: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras
S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras
More informationCU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:
CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationDisplay Panel BAT 100 LSN. en Operation Guide
Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationEY-RU 355: Room operating unit, ecounit355
Product data sheet 1.1 94.041 EY-RU 355: Room operating unit, ecounit355 How energy efficiency is improved Individual setting of occupancy and absence as well as room setpoint correction, control of lights
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationSoundwebTM. Installation Guide
105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationOperating Instructions
Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße
More informationPower supply module, bus connection module
s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can
More informationCMC III Universal Sensor
CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationM-bus web server. Meters and Energy Cost Allocation WTV676-HB6035
Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...
E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationPolymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3
Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationRXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13
s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil
More informationProduct Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23
Product Manual ASL Document Ref.: U-0618-0103.doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23 RCS01 RPA Transmitter Charging Station This equipment is designed and manufactured
More informationOriginal operating instructions Fail-safe inductive sensor GF711S / / 2013
Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding
More informationenglish S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002
S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationOriginal operating instructions Safety relay with relay outputs G1501S / / 2016
Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions
More informationOperating Instructions
TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................
More informationPKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06
PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19
More informationAccessories for stand-alone gird inverter SMART LOAD 6000
Accessories for stand-alone gird inverter SMART LOAD 6000 Technical Description SL6000-TEN081820 98-2001320 Version 2.0 EN Table of Contents Table of Contents 1 Notes on this Manual..............................
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationInstallation Manual for D244X Series 24-volt Power Supplies
Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationSliding shutter control Aluminium shutters
Sliding shutter control Aluminium shutters Operating and maintenance instructions FOR THE USER Valid from 09.2011 E 916.3 Notes These operating instructions describe how to operate the EHRET sliding shutter
More informationFeatures: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space
SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space Edition: 2 from 05.04.2018 Supercedes the edition: 1 from 04.09.2017 EN** Features: Switch 10 ports 8 PoE ports
More informationProduct Data Sheet. BMS/Graphics Interface. Features
BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationOT EASY 60 II. LED control unit Operating instructions
II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions
More informationPolymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3
Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com
More informationVR 71. Installation instructions. Installation instructions. For the competent person GB, IE. Publisher/manufacturer Vaillant GmbH
Installation instructions For the competent person Installation instructions VR 71 GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationUSER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power
Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationOPLC Installation Guide
Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs
More informationOperating Instructions Differential Pressure Transducer PS27
Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationProduct and functional description
Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationPOCKET MULTIMETER Model No: MM18
INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationPowerware 3105 UPS User s manual
Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
More informationTechnical Data sheet
Technical Data sheet XMP-K32SX-19 4/8 Door Controller The high-end real-time door control units are designed for access control, time recognition, time & attendance and building automation systems. These
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationE600 VX01 Installation guide
E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing
More informationAccessories for Sunny Central COMMUNICATION CABINET (COM-C)
Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Technical Description COM-C-TEN084210 98-4011910 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Product Details...................................
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationVision OPLC V TR6/V350-J-TR6
Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationOperating Manual FPGA-based High-Speed Micro-PLC
ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document
More informationInstallation instructions Ethernet switch EC / / 2011
Installation instructions Ethernet switch EC2095 7390731 / 00 02 / 2011 Contents 1 Preliminary note................................................. 3 1.1 Symbols used...............................................
More informationInstallation Instructions
TM Installation Instructions Manual 10 - Star Driver Modules PY-STR, PY-STR-L, PY-STR-H and PY-STR-2-H Read also: Installation Instructions, Manual 2 - Network Wiring Please read this manual completely
More informationRXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications
s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems
More informationFeatures: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras
DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationBrief Overview. Vehicle Terminal MFT12 (B183) Version: 1.10
Brief Overview Vehicle Terminal MFT12 (B183) Version: 1.10 Copyright ACD Gruppe Dieses Dokument darf ohne Zustimmung weder vervielfältigt noch Dritten zugänglich gemacht werden. 1/8 Content 1 Unpacking...
More informationEY-EM : Remote I/O module, ecolink
EY-EM 510...512: Remote I/O module, ecolink510...512 How energy efficiency is improved Optimum adjustment to applications by means of module technology. Reduction in wiring Features Part of the SAUTER
More informationMasterswitch 25kW 230V-125A Automatic AC transfer switch
INSTALLATION AND USERS MANUAL Masterswitch 25kW 230V-125A Automatic AC transfer switch MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E
E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationManual RouterNode
11.2016 Contents 2 / 21 Contents 1 General information... 3 2 Important information... 4 3 Housing... 5 3.1 Images and dimensions... 5 3.2 Dimensions of lower housing shell... 6 3.3 Opening the housing
More informationTM241CE40R controller M IO relay Ethernet
Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationQXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000
1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.
More informationPowerware 3105 UPS User s manual
Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
More informationC9900-P223 and C9900-P224
Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability
More informationChannel Switch CS. General Operating, Maintenance and Installation Manual
Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September
More information