NEUROLOGIC RESEARCH CORPORATION MODEL 1160 INITIAL DRAFT INDOOR TEMPERATURE NETWORK TRANSMITTER

Size: px
Start display at page:

Download "NEUROLOGIC RESEARCH CORPORATION MODEL 1160 INITIAL DRAFT INDOOR TEMPERATURE NETWORK TRANSMITTER"

Transcription

1 INDOOR TEMPERATURE NETWORK TRANSMITTER Ultra wide 6:1 (12-72 VDC) operating DC voltage range and 4:1 (12-50 VAC) operating AC voltage range. Low cost transmitter for indoor temperature monitoring. 0.5 degrees C accuracy Mounts on any standard single-gang wiring conduit box. Compact, thin and stylish design. Only 2.8 W x 4.55 H x 0.79 D Open communication standard using LONWORKS Protocol All outputs available using Standard Network Variables (SNVT) Dry contact input for local switch or motion sensor integration. Removable wiring terminal block for ease of wiring. All wiring is polarity insensitive. DESCRIPTION The Model 1160 is an indoor temperature transmitter that is self-contained. It contains the temperature sensor, microprocessor, measurement electronics, and network communication interface. The sensor and configuration information is communicated to other devices via the LONWORKS communication protocol. This allows multiple sensors to be used over a simple four-wire bus installation. An ultra wide 6:1 operating DC voltage range, and a 4:1 operating AC voltage range allows integration into almost any system without additional power consideration. DRY CONTACT INPUT The wiring terminal block has two terminals that are used to connect a dry contact input. This input can be used to integrate a motion sensor or a lighting switch. The interpretation of the switch input is available in many different formats via output network variables. By default the switch input is interpreted as active when the switch is closed. This can be inverted by setting nciswinvert configuration variable to ST_ON. The nvoswstate network output follows the state of the dry contact. It is set to ST_OFF when the switch is inactive and to ST_ON when switch is active. The nvoswtoggle network output toggles between ST_OFF and ST_ON each time the switch becomes active. This is ideal for turning a light on or off. For motion sensing applications, the output is available in two formats. The nvomotion and nvooccupancy are normally set to ST_OFF and OC_UNOCCUPIED respectively. They are set to ST_ON and OC_OCCUPIED respectively when the dry contact input is active and remain in that condition for a period of nciswonminutes after the switch becomes inactive. HIGH AND LOW TEMPERATURE ALARMS The Model 1160 has high and low alarm setpoints, which trigger output network variables for communicating the alarm conditions to other LonWorks products. An alarm deadband, ncitempalmdb, implements hysterisis on both alarm setpoints. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 1

2 The nvotemphialm is set to ST_ON when nvotemp is larger or equal to ncitemphialmsp and turn off when nvotemp is below ncitemphialmsp - ncitempalmdb. nvotemphialm is set to ST_NUL if hardware problems are detected. The nvotemploalm is set to ST_ON when nvotemp is lower or equal to ncitemploalmsp and turn off when nvotemp is above ncitemploalmsp + ncitempalmdb. nvotemploalm is set to ST_NUL if hardware problems are detected. STATUS LED OPERATION By default, the Status LED is on the front of the Model It is a green/orange dual color LED. The orange LED is only used as the Service LED. The green LED is used for status. It flashes to indicate that the unit is operating properly. It stops flashing to indicate an error conditions. The ncistatledoff configuration network variable is by default set to ST_OFF. It can be set to ST_ON to disable the Status LED display function. By default, ncistatlednoalms is set to ST_OFF and allows the Status LED to reflect the status of the hardware as well as the High and Low temperature alarms. If ncistatlednoalms is set to ST_ON, the Status LED will only reflect the status of hardware. WIRING AND INSTALLATION The Model 1160 is supplied with a single six position removable terminal block. The terminal block allows connection of power, network and dry contact switch input. All wiring connections are polarity insensitive. The Model 1160 accepts an ultra wide VDC or VAC for power, which connects to the terminals marked VinA and VinB. Network communications connect to terminals marked with NetA and NetB. Dry contact input connects to terminals marked with MotionA and MotionB. MotionB MotionA VinB VinA NetB NetA TERMINAL BLOCK WIRING FUNCTION NetA = Polarity insensitive FTT-10 network connection NetB = Polarity insensitive FTT-10 network connection VinA = Polarity insensitive power supply connection: VDC or VAC VinB = Polarity insensitive power supply connection: VDC or VAC MotionA = Dry contact input is attached between MotionA and MotionB MotionB = Dry contact input is attached between MotionA and MotionB SERVICE SWITCH/STATUS LED OPTIONS The Model 1160 is provided with two configurations for Service Switch, Service LED, and Status LED. The default configuration includes a front mounted Service Switch, Service LED, and Status LED. An optional configuration provides the Service Switch and Service LED on back of unit and without a Status LED. Please see ordering information. The on-board Service switch and LED allows installation on to the LONWORKS network. A 2.5 mm jack at the bottom of the unit, allows installers to connect to the NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 2

3 MODEL 1160 network for configuration or local monitoring without disturbing the main wiring. The entire unit mounts directly to any standard single-gang wiring conduit box. ADDITIONAL HARDWARE CAPABILITIES The Model 1160 is an expandable hardware platform that can easily accommodate custom applications and hardware interfaces. This is achieved through the following features. Please contact us for with your custom requirements. 1. Hardware I/O expansion can be achieved via an I2C serial bus and very high resolution A/D input capability. 2. Hardware incorporates support for on-board relative humidity sensor. Please see our Model 1260 offering. 3. Hardware incorporates support for RTD input sensor. 4. Large application memory via on-board 48K flash memory. Custom firmware can be downloaded via the communication network. 5. Ability to add LCD display with backlighting and up to four user interface buttons. Please see our Model 2020 offering. 6. Ultra wide 6:1 operating voltage range to integrate into almost any system. NETWORK INTERFACE Configuration Network Variables Configuration network variables are input network variables that are non-volatile and retained when power is lost. Network Variable Format Default Description ncitempoffset SNVT_temp_p 0.0 C Offset for temperature calibration. This value is added to nvotemp ncitempdelta SNVT_temp_p 0.3 C Minimum change required temperature network output update. nciminsendt SNVT_time_sec 5.0 seconds Minimum time between temperature network output updates even if ncitempdelta is met. ncimaxsendt SNVT_time_sec 30.0 seconds Maximum time between network variable updates whether or not changes occur. This is sometimes called heartbeat. nciminswsendt SNVT_time_sec 0.5 seconds Minimum time between alarm and switch related output network variables whether or not a change occurred. nciswinvert SNVT_lev_disc ST_OFF When set to ST_OFF the dry contact is active when closed. When set to ST_ON reverses this action. nciswonminutes SNVT_count 5.0 minutes Number of minutes nvomotion and nvooccupancy are activated. ncistatledoff SNVT_lev_disc ST_OFF When set to ST_ON disables the output status LED operation. ncistatlednoalms SNVT_lev_disc ST_OFF When set to ST_ON, the status LED will not reflect the high and low alarm conditions. ncitemphialmsp SNVT_temp_p C High temperature alarm setpoint. ncitemploalmsp SNVT_temp_p C Low temperature alarm setpoint. ncitempalmdb SNVT_temp_p 1.0 C Temperature alarm deadband. Controls temperature alarm hysterisis. Output Network Variables The Model 1160 firmware is designed to control output network variable traffic. On power up the unit randomizes the start of network updates. The ncimaxsendt configuration network variable is the send NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 3

4 heartbeat for the entire device. Output network variables will be transmitted at least once every ncimaxsendt. To disable this, set ncimaxsendt to 0. The temperature output network variables nvotemp, nvofixpttemp, nvofloattemp are only transmitted if there is a minimum of ncitempdelta change form the last transmitted value. However, they are only transmitted if nciminsendt has elapsed since last update. nciminsendt acts as a throttle to minimize traffic even if the data is changing rapidly. The nciminswsendt is the throttle for nvotemphialm, nvotemploalm, nvoswstate, nvoswtoggle, nvomotion, and nvooccupancy output network variables. Network Variable Format Description nvotemp SNVT_temp_p Temperature output 0.01 C resolution. Set to on any hardware errors. nvofixpttemp SNVT_temp Temperature output. 0.1 C resolution. Set to on any hardware errors. nvofloattemp SNVT_temp_f Temperature in floating point format. Set to 1E38 on any hardware error. nvoswstate SNVT_lev_disc State of dry contact input. ST_ON if switch is active, ST_OFF if switch is in-active. By default, switch is active when contacts are closed but can be inverted using the nciswinvert configuration variable. nvoswtoggle SNVT_lev_disc Toggle between ST_ON and ST_OFF every time the dry contact switch is activated. nvomotion SNVT_lev_disc Set to ST_ON for nciswonminutes each time the dry contact input is activated. nvooccupancy SNVT_occupancy Normally at OC_UNOCCUPIED and set to OC_OCCUPIED for nciswonminutes each time the dry contact input is activated. nvotemphialm SNVT_lev_disc High temperature alarm output status. Set to ST_ON when alarm is active, ST_OFF when inactive, and ST_NUL on any hardware error. nvotemploalm SNVT_lev_disc Low temperature alarm output status. Set to ST_ON when alarm is active, ST_OFF when inactive, and ST_NUL on any hardware error. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 4

5 MODEL 1160 GENERAL SPECIFICATIONS Temperature Sensing Element Accuracy Temperature Range Resolution Electronics Operating Environment CPU Input Power Input Power Protection Network Transceiver Type Solid State +/- 0.5 C typical over entire operating range 0 to 70 C 0.1 C 0 to 70C, 0-95% RH non-condensing 3150 Neuron with 48K Flash 12 to 72 VDC or 12 to 50 VAC at 0.5VA maximum. Input power is fused and transient voltage protected. (Fuses do not need to be replaced) Echelon FTT-10A transceiver at 78 kbps. Up to 100 volts DC blocking capacitors for LPT10 network. Dimension and Materials Electronics Compartment 2.8 W x 4.55 L x 0.79 H Sensor Compartment 0.5 W x 1.35 L x 0.54 H Housing Material ABS Plastic 2.80" 4.55" 1.35" 0.50" 0.54" 0.79" NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 5

6 ORDERING INFORMATION 1160 Model 1160 Indoor Temperature Network Transmitter Code Network Transceiver Option -0 TP/FTT-10A Code Configuration Options -0 Basic Unit with Service Switch, Service LED and Status LED on front -1 Basic Unit with Service Switch and Service LED on back. No Status LED. Code Housing Color -0 White ABS Plastic Housing Model 1160 with FTT-10A transceiver, white ABS housing with Service switch, service LED, and Status LED on front Echelon, LON, LONWORKS, Neuron, 3120, 3150, LONMARK are trademarks of Echelon Corporation. NEUROLOGIC RESEARCH CORPORATION Copyright (c) 2005 Rev. 0 Page 6

MODEL 2000T Initial Draft

MODEL 2000T Initial Draft TEMPERATURE DISPLAY AND COMMAND MODULE On-board temperature sensor. Mounts on any standard single-gang wiring conduit box. Compact, thin and stylish design. Only 2.8 W x 4.55 H x 0.79 D Sensing element

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

NEUROLOGIC RESEARCH CORPORATION MODEL 2150 NEUROLOGIC RESEARCH CORPORATION FOUR DIGITAL INPUT / FOUR DIGITAL OUTPUT NETWORK NODE - Very compact design available in DIN Rail and NEMA 4X enclosures. - LonWorks FTT-10A network interface with all inputs

More information

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY FEATURES Highly visible fluorescent alphanumeric display able to operate over a temperature range of -40 to 85 C Large 0.43 high numeric display format. 1/8 DIN panel-mount enclosure. Multiple display

More information

DESCRIPTION WIRING AND INSTALLATION. LonWorks Utility Metering Display NOTE

DESCRIPTION WIRING AND INSTALLATION. LonWorks Utility Metering Display NOTE Supports many common gas, water, and power meter output network variable types. Supports NeuroLogic Research s Model 2200VM & 2200PM products as well as Continental Controls WattNode LonWorks product.

More information

FEATURES DESCRIPTION MODEL 110B. Power Supply

FEATURES DESCRIPTION MODEL 110B. Power Supply FEATURES Extends wiring distance of FT-10 LonWorks Networks. (2) channels using a single Model 110B. Up to 10 channels using (5) Model 110B. Low cost alternative to routers configured as repeaters. Wring

More information

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1 1201L-1K RTD Controller Revision 1.1 Nico Technology Ltd. 24F,No.37,SanMin Rd, 2.Sec, PanChiao City, Taipei County, Taiwan Phone +886-2-2954-5338 Fax +886-2-2954-5308 Product Info Thomas@nico-tech.com

More information

RCM Room Command Module New Style

RCM Room Command Module New Style LONWoRKS Compatible Controllers Manual Product Bulletin Issue Date 08 2005 RCM Room Command Module New Style The newly styled RCM Room Command Module is designed for use with LONMARK compliant space comfort

More information

LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object

LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object Version 1.0 Refrigerated Display Case Controller Defrost Object : 10010 LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object 10010-10 1997, LONMARK Interoperability Association

More information

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES PRODUCT DATA APPLICATION The LON actuator is targeted for decentralized building structures and gives customers an effective new capability in energy

More information

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description Display Panel for Toshiba air-conditioning units Description The RealTime is a monitoring panel compatible with the Toshiba LG1 air-conditioning control interface. The XDP displays the current operating

More information

LX Series Remote Input/Output (I/O) Controller

LX Series Remote Input/Output (I/O) Controller LX Series Remote Input/Output (I/O) Controller Product Bulletin LX-IO520-1, LX-IO401-1, LX-IO301-1 Code No. LIT-12011491 Issued June 22, 2009 The LX Series Remote Input/Output (I/O) controller extends

More information

Actuator Zone 1 Mar 2004

Actuator Zone 1 Mar 2004 MZ18L G-50-30 Actuator Zone 1 Mar 2004 The LON actuator is targeted for decentralized building structures and gives customers an effective new capability in energy management and product flexibility. The

More information

NETWORK VARIABLES SPECIFICATIONS. LN INTERFACE Model: TCB-IFLN642TLE

NETWORK VARIABLES SPECIFICATIONS. LN INTERFACE Model: TCB-IFLN642TLE NETWORK VARIABLES SPECIFICATIONS LN INTERFACE Model: TCB-IFLN642TLE Input Network Variables 1 START/STOP instructions nvionoff[n] STOP START (state=1 or value>0) Switches START/STOP. 2 Operation mode nvihvacmode[n]

More information

ECP-PTU Series. ECP-PTU Series. 14-Point High-Voltage Programmable Power Terminal Unit Controller. Applications. Features

ECP-PTU Series. ECP-PTU Series. 14-Point High-Voltage Programmable Power Terminal Unit Controller. Applications. Features ECP-PTU Series 14-Point High-Voltage Programmable Power Terminal Unit Controller Applications Control of equipment such as: roof top units, fan coils, heat pumps, ventilator units, terminal units, lighting

More information

TALON Network Manager- 2 & 6 Express

TALON Network Manager- 2 & 6 Express Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform

More information

DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO

DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO Corso DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO Docente: Ing. Luca Romanelli Mail: romanelli@baxsrl.com Protocolli LonWorks Domotica ed edifici intelligenti Università di Urbino 1 Concept Definitions

More information

CTR21, CTR22, CTR23, and CTR24 Wall Modules

CTR21, CTR22, CTR23, and CTR24 Wall Modules CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500

More information

IQ-SBS LCU Series Installation Instructions

IQ-SBS LCU Series Installation Instructions Installation Instructions LCU-1 The IQ-SBS LCU-1 is a self-contained device for integrating control of facility lighting with IQ-SBS. The LCU-1 controls lighting zones, accepts input from override switches

More information

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES AND OPTIONAL PI-CONTROL

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES AND OPTIONAL PI-CONTROL M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES AND OPTIONAL PI-CONTROL CONTENTS APPLICATION... 2 FEATURES... 2 DEVICE SPECIFICATIONS... 3 OPERATION... 3 VERSIONS... 3 PLUG-INS, XIF FILES AND DRF FILES...

More information

TAC Xenta 301. Controller, Freely Programmable

TAC Xenta 301. Controller, Freely Programmable TAC Xenta TAC Xenta 300 Controller, Freely Programmable TAC Xenta 300 belongs to a family of freely programmable controllers designed for small and medium-sized heating and air handling systems. A TAC

More information

Stryker Lon Configurable Controllers

Stryker Lon Configurable Controllers Stryker Lon Configurable Controllers SPECIFICATION DATA FEATURES GENERAL The CVL4022AS-VAV1 and CVL4024NS-VAV1 controllers are part of the Stryker family. The controllers are Free Topology Transceiver

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features ECP-VAV Series 10-Point Single Duct VAV / VVT Free Programmable Controller Applications Designed to meet the requirements of single duct variable air volume (VAV) or variable volume according to temperature

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS LonWorks Communication Card RXRX-AY02 RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION! WARNING THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

LLR-MOD Modbus Light Level and Occupancy Sensor

LLR-MOD Modbus Light Level and Occupancy Sensor Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

MOD-RI Room Interface Modules with Modbus

MOD-RI Room Interface Modules with Modbus Product sheet MOD3.00 Type MOD-RI MOD-RI Room Interface Modules with Modbus The MOD-RI are room interface modules designed to provide room control interface for the building management systems. The MOD-RI

More information

LN Series Remote Input/Output (I/O) Modules

LN Series Remote Input/Output (I/O) Modules LN Series Remote Input/Output (I/O) Modules Product Bulletin LN-IO301-1, LN-IO401-1, LN-IO520-1 Code No. LIT-12011316 Issued June 5, 2012 Supersedes November 9, 2007 The LN Series Remote Input/Output (I/O)

More information

TAC Xenta 280 UC-01 UC-02 UC-03

TAC Xenta 280 UC-01 UC-02 UC-03 TAC Xenta 280 UC-01 UC-02 UC-03 Programmable Controller 15 Dec 2002 TAC Xenta 280 belongs to a family of programmable controllers designed for Zone control or small sized heating and air handling systems.

More information

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action Electric Actuators with LON Interface Type 5824 without Type 5825 with fail-safe action Fig. 1 Type 5824 Actuator Mounting and Operating Instructions EB 5824-9 EN Edition June 2003 Contents Contents Page

More information

Power Modular Equipment Controller

Power Modular Equipment Controller Technical Specification Sheet Rev. 1, June, 23 Power Modular Equipment Controller Figure 1. Power Modular Equipment Controller in small enclosure with service box. The Modular Equipment Controller (MEC,

More information

LTEC Heat Pump DDC Controller

LTEC Heat Pump DDC Controller Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller

More information

Remote I/O R7 Series LNS PLUG-IN SOFTWARE Model: R7LPLG Users Manual

Remote I/O R7 Series LNS PLUG-IN SOFTWARE Model: R7LPLG Users Manual Remote I/O R7 Series LNS PLUG-IN SOFTWARE Model: R7LPLG Users Manual 1 CONTENTS 1. GENERAL...3 1.1 R7L REMOTE I/O FEATURES...3 1.2 R7LPLG SOFTWARE...3 1.3 HARDWARE REQUIREMENTS...3 1.4 INSTALLING & DELETING

More information

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U) (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications

More information

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker. MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (I/O points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATION Code number: R-NL-[][] Specify a code from below for each []

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature

More information

Self-Adjusting Ultrasonic Wall Switch Sensor

Self-Adjusting Ultrasonic Wall Switch Sensor -1 06.09.05 Self-Adjusting Ultrasonic Switch Sensor The ultrasonic offers a direct and quick replacement of wall switches for stand-alone line voltage switching of small spaces. The intelligent, continuously

More information

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware

More information

Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet

Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet Features Connects twisted pair LonWorks nodes to fibre optic back-bones, links or subnets Linear Bus or Ring network topology Single-Fibre

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Installation- & user instructions

Installation- & user instructions Installation- & user instructions for NILAN LON module for CTS6000 Valid for: CTS6000, - SW 1.0064. Version 1.04, 08.12.2011 Contents Contents... 2 Figure table... 3 General description of NilLON... 4

More information

LON-module for MULTICAL 601

LON-module for MULTICAL 601 LON-module for MULTICAL 601 Type 67-00-24-000-000 i n s t a l l a t i o n Kamstrup A/S Industrivej 28, Stilling, DK-8660 Skanderborg TEL: +45 89 93 10 00 FAX: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com

More information

LOCAL DISPLAY UNIT (LDU)

LOCAL DISPLAY UNIT (LDU) LOCAL DISPLAY UNIT (LDU) The LDU200 is a LonWorks -based networked user interface panel used to display data and edit setpoint variables for vivariums, bio-containment, laboratory spaces, operating rooms,

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

Excel Smart I/O Compact XFCL2A1 AND XFCL3A1

Excel Smart I/O Compact XFCL2A1 AND XFCL3A1 GENERAL The Excel Smart I/O Compact is suitable for installation at strategic locations throughout your buildings. It features three digital inputs, three analog inputs, three relay outputs, as well as

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

Operation and Maintenance Manual

Operation and Maintenance Manual VM Series Operation and Maintenance Manual VM - Voltage Monitor VM-100-24 V VM-100-48 V VM-100-125 V VM-100-250 V EAGLE EYE POWER SOLUTIONS All Rights Reserved. 1 The Voltage Monitor series reads battery

More information

LON Module for Variable Speed Drive

LON Module for Variable Speed Drive 5 193. LON Module for Variable Speed Drive SED2 Conforms to and is certified to the LONMARK Interoperability Guidelines enabling information sharing with other LONMARK products. LONMARK-compliant with

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

Micro Motion Model 7950 and Model 7951 Signal Converters

Micro Motion Model 7950 and Model 7951 Signal Converters Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion

More information

FUME HOOD CONTROLLER (FHC)

FUME HOOD CONTROLLER (FHC) CRITICAL CONTROLS - PRODUCT OVERVIEW FUME HOOD CONTROLLER (FHC) The FHC is designed to control face velocity on variable volume fume hoods with audible and visual indicating alarms. The Fume Hood Controller

More information

PURE SINE WAVE INVERTER REMOTE GP-ISW-R-12/24

PURE SINE WAVE INVERTER REMOTE GP-ISW-R-12/24 PURE SINE WAVE INVERTER REMOTE GP-ISW-R-2/24 User Manual GP-ISW-R 5 4 3 2 0 gpelectric.com GP-ISW-R 20 Go Power! By Carmanah Technologies Worldwide Technical Support and Product Information gpelectric.com

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

LX Series Free Programmable Controllers

LX Series Free Programmable Controllers Code No. LIT-1900565 Issued November 5, 2012 LX-PRG203-1, LX-PRG300-1, LX-PRG4x0-1, LX-PRG5x0-1 LX Series Free Programmable Controllers Description The LX Series Free Programmable Controllers are microprocessor-based

More information

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE ompact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE INSTALLATION INSTRUTIONS Terminal Blocks: Supply and Bus: 16 AWG (1.5 mm²). (terminal block and strapping plug included with packing). Analog Outputs:

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.

More information

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2. BARIX IO12 I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL Version: 2.01 Date: 06/03/2014 For Firmware Version 10 Table of Contents

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

Process Indicator Controller (Digital) (Product code 3.1 to 3.15)

Process Indicator Controller (Digital) (Product code 3.1 to 3.15) Process Indicator Controller (Digital) (Product code 3.1 to 3.15) DPI-720 / DPI-12 DPC-300 DPC-22 DPI-4000 DPI-480 DPI-720 FLP Model Wise Descriptions: Process Indicators: (3.1 to 3.9) Sr.No. Model Product

More information

Actuator Commissioning Tool

Actuator Commissioning Tool Document No. 129-287 Actuator Commissioning Tool Product Description The 985-047 Actuator Commissioning Tool provides a portable instrument for exercising, calibrating, and testing resistive, proportional

More information

Proportional Control Unit (PCU)

Proportional Control Unit (PCU) Proportional Control Unit (PCU) HQ-006 to HQ-300 Installation & Maintenance Manual The EIM HQ Series PCU is a Digital positioner with a Microprocessor and 12-bit A/D converter. By moving the actuator to

More information

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

MOD-IO9 Modbus Input / Output Modules, Wall Mounted Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module

More information

VAT series controller and transmitter. Manual

VAT series controller and transmitter. Manual VAT series controller and transmitter Manual 1. General describe.. 2. Notice for use.. 1 1 3. Panel & connection introduce.. 2 4. Operate introduce.. 5. Application introduce. 6. Communication. 7. Specification..

More information

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output. INTRODUCTION The Digital Futronic module uses the latest integrated microcontroller technology to enable one electronics module to perform valve actuator modulating and positioning control from analog

More information

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC 1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include

More information

Stryker Lon Configurable Controllers

Stryker Lon Configurable Controllers Stryker Lon Configurable Controllers SPECIFICATION DATA The Stryker controllers require the Stryker Feature to be licensed in the WEBpro workbench tool and the WEBS AX JACE Controller for programming and

More information

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication. HTC-DIGITAL-LCD Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication. Features Use Australian Made and designed LCD 2 X 16 Character Backlit Display Five Programmable

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

Installation- & user instructions

Installation- & user instructions Installation- & user instructions for NILAN LON module for CTS6000 Valid for: CTS6000, SW 1.0092 Version 1.07, 16-12-2015 Contents Contents... 2 Figure table... 3 General description of NilLON... 4 Installation...

More information

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013 Technical Specification Sheet Document No. 149-476 July 18, 2013 TX-I/O Product Range TX-I/O is a range of I/O modules, with associated power and communication modules, for use within the APOGEE Automation

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

Micro Instruments price list All pricing excludes 15%

Micro Instruments price list All pricing excludes 15% Micro Instruments price list All pricing excludes VAT @ 15% - 2019 Product Description Solar Smart R1 Solar MPPT regulator 12/24V - 20Amp with R2 799.00 5 Way Relay board R360.00 Ethernet + SNMP support

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

DIGITAL PANEL METERS

DIGITAL PANEL METERS DIGITAL PANEL METERS 3 1/2 digit,4 1/2 digit - A/C D/C Voltage/Current 3 1/2 digit4 1/2 digit- AC/DCVoltage/Current-TRMS DPM U AC/DC VOLTAGE / CURRENT 3 1/2 DIGIT - MODEL : PE 3000 4 1/2 DIGIT - MODEL

More information

PG AC Modbus TCP to LonWorks Protocol Converter

PG AC Modbus TCP to LonWorks Protocol Converter PG-101-105-AC Modbus TCP to LonWorks Protocol Converter PG-101-105-AC is highly powerful, superior, completely configurable and productive Building & Industrial Automation gateway for integrators to effortlessly

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

VIRTU TM Analog Ultrasonic Sensors

VIRTU TM Analog Ultrasonic Sensors Model VM Analog Series VIRTU TM Analog Ultrasonic Sensors The next generation of compact ultrasonic analog sensors that outperforms many other sensor types in all types of applications. The new Virtu Analog

More information

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules Product Bulletin LX-PRG600-11, LX-PRG610-11, LX-IOE400-0 LX-IOE410-0, LX-IOE420-0 Code No. LIT-12011854

More information