1 77 WIRIG REGULATIO st Amendment implemented st January 0 KEY ECTIO Chapter 44 Voltage disturbances and electromagne c disturbances ec on 44 rotec on against over voltages of atmospheric origin or due to switching Chapter rotec on, Isola on, witching, Control and Monitoring ec on 4. elec on and erec on of surge protec on devices urge rotec on Devices () and the 7 th Edi on st Amendment of 77 Wiring Regula ons urge rotec on devices available from DEM Manufacturing (branded Roxburgh EMC) have for many years offered market leading protec on from damage caused by high energy short dura on electrical transients. These are typically caused by nearby electrical storms (atmospheric origins) or the switching of induc ve, capaci ve and resis ve loads (switching origin). Transients can cause a variety of problems from equipment failure to serious electrical fires and damage to distribu on systems. urge rotec on Devices have historically not been covered by 77 Wiring Regula ons, despite the vital role they can play in protec ng electrical and electronic equipment. However, this has now changed with the recently published first amendment implemented st January th Edi on, Chapter 44 relates to protec on against Voltage Disturbances and Electromagne c Disturbances. ec on 44 deals specifically with protec on against over voltages of atmospheric origin or due to switching. Details are given as to the types of installa ons where the risk assessment will always lead to the result that is required and other areas with lower levels of consequences where calcula ons can be used to determine the need for installa on. ee specifically Chapter deals with protec on isola on, switching, control and monitoring with 4. determining specifically the selec on and erec on of surge protec on devices. Two specific types of are referred to in the regula ons as Type and Type dependant on the nominal discharge currents expected and the loca on of the protec on within the system. DEM s urge rotec on Devices meet E 4 and DEM s class (DV series) meet Type and DEM class C (DVC series) urge rotec on Devices meet Type specifica ons as referred to in chapter. 7 th Edi on st Amendment urge rotec on Devices Roxburgh Item ystem upply Appendix Diagram Type/Type DVC40044T TT connec on Type hase + eutral A Type DVC40044TT TT connec on Type hase + eutral A Type DVC4004TC IT hase A4 Type DV4004T T C hase + eutral A Type DVC40044T T C hase + eutral A Type DVC74T T C ingle hase A Type Contact our Technical ales team on +44 (0) 74 7 We will be happy to answer any ques ons or help with product selec on, Hargreaves Way, awcliffe Industrial ark, cunthorpe, orth Lincolnshire. D 8RF Tel: +44 (0) sales@dem uk.com uk.com/roxburgh
2 Tel o. +44(0)74 7 Hargreaves Way, awcliffe Ind. ark, cunthorpe, orth Lincolnshire, D 8RF, UK art o: DVC40044T IUE UMER 0 DVC40044T urge rotection Device recommended for use with TT systems, connection Type (CT ) connected to the load side of an RCD according to regulation 4..(i) OCD I L L L rotective Conductor OCD 4b 4a :. Distribution board. Main earthing terminals or bar. urge protective devices ensuring a protection level in accordance with overvoltage Category II 4. Earthing connection of surge protective devices, either 4a or 4b, whichever is the shorter route. Current-using equipment. Residual current protective device (RCD) OCD : at the origin of the installation OCD : >A gl A gl Min. recommended cross section mm² 04/04/0 0/04/0
3 Tel o. +44(0)74 7 Hargreaves Way, awcliffe Ind. ark, cunthorpe, orth Lincolnshire, D 8RF, UK art o: DVC40044TT IUE UMER 0 urge rotection Device recommended for use with TT systems connection type (CT) connected to the load side of an RCD according to regulation 4..(ii) OCD L L L I rotective Conductor OCD 4b a 4a :. Distribution board. Main earthing terminals or bar. urge protective devices a. urge protective devices (s and a in series ensuring a protection level in accordance with overvoltage Category II. 4. Earthing connection of surge protective devices, either 4a or 4b, whichever is the shorter route. Current-using equipment. Residual current protective device (RCD) installed downstream of the surge protective devices OCD : OCD : at the origin of the installation >A gl A gl Min. recommended cross section mm² 0/04/0 4/04/0
4 Tel o. +44(0)74 7 Hargreaves Way, awcliffe Ind. ark, cunthorpe, orth Lincolnshire, D 8RF, UK art o: DVC4004TC IUE UMER 0 urge rotection Device recommended for use with IT systems OCD I L L L rotective Conductor z OCD 4b 4a Distribution board Main earthing terminals or bar urge protective devices ensuring a protection level in accordance with overvoltage Category II Earthing connection of surge protective devices, either 4a or 4b, whichever is the shorter route Current-using equipment Residual current protective device (RCD) OCD : OCD : at the origin of the installation >A gl A gl Min. recommended cross section mm² 0/04/0 4/04/0
5 Tel o. +44(0)74 7 art o: Hargreaves Way, awcliffe Ind. ark, cunthorpe, orth Lincolnshire, D 8RF, UK T-C- YTEM 0 IUE UMER Installation of types, and s for example in T-C- systems ource ee note 4 Installation ee note OCD 9 OCD 4 L 9 L L E E OCD OCD : : Distribution board Distribution outlet Main earthing terminal or bar urge protective device, DV4004T (Type ) Earthing connection (earthing conductor) of surge protective device fixed equipment to be protected urge protective device, DVC40044T (Type ) urge protective device, DVC74T (Type or Type ) Decoupling element or line length 8: OTE : for further information reference should be made to CLC/T4- OTE : s 4 & 7 (or 7 & 8) can be combined in a single OTE : s may require additional modes of protection for sensitive equipment OTE 4: E 0-4 covers the protection of electrical and electronic systems within structures against lightning. OTE : ection 44 of 77 deals with the protection of electrical installations against transient overvoltages of atmospheric origin, transmitted by the supply distribution system and against switching overvoltages generated by the equipment within the installation 0/04/0 4/04/0
6 Tel o. +44(0)74 7 Hargreaves Way, awcliffe Ind. ark, cunthorpe, orth Lincolnshire, D 8RF, UK art o: T-C- YTEM IUE UMER 0
Lightning & Surge Protection
Watchful Eye olutions, Inc. WTH-300, WTH-500/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-300/G
More informationLightning & Surge Protection
Watchful Eye olutions, Inc. WTH-120, WTH-165/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-165/G/1-255
More informationTechnology Live Workshop
Technology Live Workshop David Pitt Product Manager Eaton Electric Ltd. Technology Live Workshop Subjects to be covered in this Technology Live Workshop: Increased need for installation of transient voltage
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES SUITABLE SOLUTIONS FOR ALL TYPES OF INSTALLATIONS AND ALL RISK LEVELS 1 CONTENT: Introduction Theory and principles Installation rules Legrand offer 2 2 INTRODUCTION Lightning
More informationOvervoltage Protection
Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning
More information3 Design of the electrical installation protection system
J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design
More informationModular surge protective devices
S D 870 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Modular surge protective devices Cat. o(s): 039 10-030 00/0//3/7 age /L 1. General characteristics... 1. Overall dimensions....1-3.
More informationLightning Current Equipotential Bonding SPDs
Lightning Current Equipotential Bonding SPDs Introduction Furse is a world leader in the design, manufacture, and supply of earthing and lightning protection systems. Over 100 years of experience makes
More informationBS th Edition wiring regulations Furse overview
BS 7671 18th Edition wiring regulations Furse overview Transient overvoltage protection TRANSIENT OVERVOLTAGE PROTECTION - RISK ASSESSMENT TO BS 7671 Furse electronic systems protection Enhanced solutions
More information2 Principle of lightning protection
2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical
More information17 th Edition (BS 7671:2008) incorporating Amendment No 1
20 17th Edition 17 th Edition (BS 7671:2008) incorporating Amendment No 1 Installations designed from the 1 st January 2012 are to comply with Amendment number 1. Geoff Cronshaw The first amendment to
More informationBETA Protecting Overvoltage Protection Devices
iemens AG 2008 BETA rotecting Overvoltage rotection evices /2 roduct overview /3 Lightning arresters, type 1 /5 Combination surge arresters, type 1 and type 2 /7 urge arresters, type 2 /13 urge arresters,
More informationEquipment protection
Equipment protection Serie K Risk of electrical surges Equipment protection 5.000.000 ightning strikes per day 61% Electrical damages caused by surges 30k verage current of a lightning strike ightning
More information6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2
iemens AG 2009 BETA rotecting Overvoltage rotection evices /2 roduct overview /3 Lightning arresters, type 1 /5 Combination surge arresters, type 1 and type 2 /7 urge arresters, type 2 /13 urge arresters,
More informationCONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 3
CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 3 Thomas B. Jones 1 Introduction Operators and managers consider outages, operational faults and interruptions
More informationThe Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE
The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination Hans Slagter, DEHN + SOHNE Earthing, Bonding & Surge Protection Conference, Auckland 2012 Discussion topics 1. Introduction
More informationCirprotec Technical Article No. 5
Lightning and surge protection in waste water purification plants (WWTPs and DWTPs) Cirprotec Technical Article No. 5 2010 CIRPROTEC All rights reserved 2012 CIRPROTEC All rights reserved Cirprotec Technica
More informationLightning and Surge Protection for PV Systems
Lightning and Surge Protection for PV Systems Application Note (AU) Phillip Tompson Introduction Like all electrical equipment photovoltaic systems can be damaged by both direct and indirect lightning
More informationCommercial and Industrial LV Power Protection
Commercial and Industrial LV Power Protection Surge protection in Australia Tristan King Contents Introduction... 1 What is a Surge?... 1 Surge Protection Device... 2 Surge Protection Categories... 2 Category
More informationChapter J. Protection against voltage surges in LV. Contents. General. Overvoltage protection devices. Choosing a protection device
Chapter J Protection against voltage surges in LV 1 2 3 4 Contents General J2 1.1 What is a voltage surge? J2 1.2 The four voltage surge types J2 1.3 Main characteristics of voltage surges J4 1.4 Different
More informationOvervoltage Protection for low-voltage supplies
Class I Overvoltage Protection.2 -.3 with sparkover gaps.4 -.9 with high-power varistors.10 -.11 Overvoltage Protection, combination arrester.12 -.15 Class II Overvoltage Protection with varistors.16 -.25
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationITU-T K.66. Protection of customer premises from overvoltages SERIES K: PROTECTION AGAINST INTERFERENCE. Recommendation ITU-T K.
International Telecommunication Union ITU-T K.66 TELECOMMUICATIO STADARDIZATIO SECTOR OF ITU (06/2011) SERIES K: PROTECTIO AGAIST ITERFERECE Protection of customer premises from overvoltages Recommendation
More informationELPROMA NTSprotect Surge Protection
ELPROMA NTSprotect Surge Protection Rack 19 back panel with NTS-protect As the antenna is roof mounted (to have a clear view of the sky) it is likely to be exposed to lightning strikes. Protection against
More informationWhite Paper Surge Protective Devices in Automatic Transfer Switches
White Paper Surge Protective Devices in Automatic Transfer Switches Standby power systems provide emergency power, legally required power, or optional standby AC power during utility outages. Standby AC
More informationSystems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.
PSTN Protection The demand for voice and data communications has never been greater. Today, virtually everyone in the developed world has access to a land-line telephone, which carries their voice or data
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationENGR. MARITES R. PANGILINAN, P.E.E.
ENGR. MARITES R. PANGILINAN, P.E.E. WHAT IS LOW VOLTAGE INSULATION COORDINATION AND WHY IT IS IMPORTANT WHERE DO SURGES COME FROM HOW DO SPDs WORK/TYPE OF SPDs SPD SPECIFICATIONS SPD COORDINATION /CASCADING
More informationReliability in Surge Protection. Photovoltaic Systems.
Reliability in Surge Protection Photovoltaic Systems www.citelcp.com Roof top installations For low power PV applications, i.e. residences and small offices, it is necessary to consider surge protecting
More informationOPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL
OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT KEPCO INC. An ISO 9001 Company. MODEL 250W ATE 6-25, ATE 15-15, ATE 25-10, ATE 36-8, ATE 55-5, ATE 75-3, ATE 100-2.5, ATE 150-1.5, ATE
More informationBackpanel Attaching Hardware. Molded-in Threaded Housing for Mounting. Enclosure. Enclosure. Backpanel. Fuse Holder with Series Fuse
ombination Lightning rotection and Transient Voltage urge uppression TV nstallation nstructions 63D N 56562 Models 0/240 V A, plit, ingle-phase Enclosures: 5602856, 5603167, 5603416, 5603417 & Kit: 5603030
More informationELECTRICAL INSTALLATIONS OF BUILDINGS -- PART 4-44: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND
IRISH STANDARD I.S. HD 60364-4-443 ICS 91.140.50 ELECTRICAL INSTALLATIONS OF BUILDINGS -- PART 4-44: PROTECTION FOR SAFETY - PROTECTION AGAINST VOLTAGE DISTURBANCES AND ELECTROMAGNETIC DISTURBANCES --
More informationEUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg
PR EUSR An Introduction To BS7671 Amendment 3:2015 featuring Consumer Units for Domestic (Household) Premises as per Reg. 421.1.201 DESIGNED FOR 2015 Third Amendment Update Significant Change 3rd Amendment
More informationBS EN :2012 Part 2: Risk Management
BS EN 62305-2:2012 Part 2: Risk Management 2 - BS EN 62305 Risk Management 1 Lightning protection standardisation BS EN 62305-2 62305-1 General Principles 62305-2 Risk Management 62305-3 Physical damage
More informationCPS block & CPS nano UL rd Ed. Surge protective devices (SPD)
V4 Cirprotec CPS block & CPS nano UL 1449 3rd Ed. Surge protective devices (SPD) Transient voltage surge suppressors (TVSS) Cirprotec, more than just protection Cirprotec, specialists in lightning and
More informationModular surge protective devices (SPDs) Cat. Nos :
Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information
More informationLIGHTNING PROTECTION
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 8 LIGHTNING PROTECTION Aim is to protect: People Buildings and Contents
More informationPHOTOVOLTAIC PLANTS Comprehensive lightning protection
PHOTOVOLTAIC PLANTS Comprehensive lightning protection 1. Introduction Photovoltaic (PV) plants are composed of many panels supported on large metal structures, located in open areas and normally highly
More informationLightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany
Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationRegulatory Update Brazil
Product Compliance Specialists Ltd Tel: +44 1844 273 277 The Malthouse, Malthouse Square, Fax: +44 1844 273 278 Princes Risborough www.productcompliancespecialists.com Bucks, HP27 9AZ info@productcompliancespecialists.com
More informationMaking the Right Choices In Lightning & Surge Arrestors Some Basics:
Making the Right Choices In Lightning & Surge Arrestors Some Basics: It is a fact that the Highveld region of South Africa and Lesotho have amongst the highest lightning strikes per square km per annum
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationSurge Protection for Low Voltage Power Systems
Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution
More informationProtection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device
Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE Surge Protection Device CHOICE OF SURGE PROTECTION DEVICES FOR PHOTOVOLTAIC APPLICATIONS General concept To achieve complete functionality
More informationvoltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection
voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main
More informationType Code No. Weight Packaging [g] [pcs]
Surge arresters surge arresters are intended for protection of electrical installations and devices against overvoltage effects, which may occur in atmospheric discharges and switching overvoltages. The
More informationFENCE ENERGIZER I SERIES. Instructions - ENG
FENCE ENERGIZER I SERIES Instructions - ENG PUBLISHED BY Gallagher Group Limited 181 Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagher.com Copyright Gallagher Group Limited 2016 All
More informationMinia. Application manual Overvoltage protections
Minia Application manual Overvoltage protections www.oez.com Overvoltage protections Minia CONTENTS THEORETICAL PART 1. PRINCIPLE OF PROTECTION AGAINST LIGHTNING AND OVERVOLTAGE... 3 1.1. Switching overvoltage...
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationonlinecomponents.com Overvoltage protection Contents Overvoltage protection Overvoltage protection F.1
Contents for low-voltage supplies.2 for instrumentation and control equipment.40 for data interfaces.88.1 for low-voltage supplies for low-voltage supplies Class I overvoltage protection with sparkover
More informationAN4275 Application note
AN4275 Application note IEC 61000-4-5 standard overview Introduction The objective of this document is to briefly explain the IEC 61000-4-5 standards and to show the benefits of having a range of protection
More informationRTU500 series Data Sheet Power Supply CP-E 24/2.5
Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped
More informationRE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O
Characteristics StarDelta Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationContent. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.
Content Time delay relays mounting position Multifunctional time delay relay... 3.2 Clock-pulse generator time delay relay... 3.10 Multifunctional clock-pulse generator relay... 3.14 Technical safety advice...
More informationManual for overvoltage protection for LED luminaires rev 1
Kurtatsch, Italy, February 10, 2017 Manual for overvoltage protection for LED luminaires rev 1 Through the introduction of LED luminaires, substantial improvements have been achieved with respect to conventional
More informationSession Two: Effective Surge Protection Installation
Abstract Session Two: Effective Surge Protection Installation Phillip Tompson Managing Director, Novaris Pty Ltd This paper provides an outline of how to effectively install surge protection to various
More informationRMCN22BD Analog Converter ma - for Zelio Analog
Characteristics Analog Converter - 4..20 ma - for Zelio Analog Main Commercial Status Range of product Product or component type Analogue input type Analogue output type Commercialised Zelio Analog Voltage/Current
More informationCirprotec. Specialists in Lightning and Surge Protection for Photovoltaic Systems. Includes new plug-in SPD range and insulation monitoring device
A1 Cirprotec Specialists in Lightning and Surge Protection for Photovoltaic Systems Includes new plugin range and insulation monitoring device Complete protection systems with maximum continuity of service
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationModular UPS S KVA
Scalable 3 - phase, double conversion UPS system with hot-plug design up to 220 KVA (n + 1). The modular design with 20 KVA modules makes any system up or downgrade flexible and avoids high inv estment
More informationMFJ-1164B AC Line RFI Filter
Introduction MFJ-1164B AC Line RFI Filter Thank you for purchasing the MFJ-1164B AC Line RFI Filter. This is a versatile AC Filter that can be used with all types of sensitive equipment that needs AC line
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationRE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics Ondelay Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationAarlogic TER-GX910. Product description. Rev.9 17/03/2013
Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface
More informationGallagher T12 Reader. Installa on Note. The Gallagher T12 Reader
ATTENTION: This equipment contains components that can be damaged by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing. The The is a smart card proximity
More informationSecondary Surge Arrester Instruction Manual Page 1 of 5
Secondary Surge Arrester Instruction Manual Page 1 of 5 GENERAL SAFETY INSTRUCTIONS WARNING: ARRESTER CAN FAIL VIOLENTLY AND CAUSE INJURY AND PROPERTY DAMAGE WHEN APPLIED AT VOLTAGES GREATER THAN 120V.
More informationExternally Gapped Line Arresters Smart Solution for Stable Power Supply
Smart Solution for Stable Power Supply Metal-oxide surge arresters with external series gaps improve the reliability of transmission systems, and help eliminate not only lightning damages of transmission
More informationUniversal Power Supplies
, Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC
More informationCatching Falling Conductors in Midair Detecting and Tripping Broken Distribution Circuit Conductors at Protection Speeds
Catching Falling Conductors in Midair Detecting and Tripping Broken Distribution Circuit Conductors at rotection Speeds Karl Iliev San Diego Gas & Electric Company Eric Udren Quanta Technology, LLC Copyright
More informationNEW surge protective devices
NEW surge protective devices For use in low-voltage systems For overhead power lines and buildings Made in EU ABOUT COMPANY INTRODUCTION Company ELEKTROMEHANIKA & BB d.o.o. was established from recent
More informationelectrical disturbances how to protect businesses
electrical disturbances how to protect businesses taking responsibility At your business, the efficient use of energy brings benefits such as lower bills, improved comfort levels for your customers and
More informationExternally Gapped Line Arresters Smart Solution for Stable Power Supply
Smart Solution for Stable Power Supply Metal-oxide surge arresters with external series gaps improve the reliability of transmission systems, and help eliminate not only lightning damages of transmission
More informationThis is a preview - click here to buy the full publication TECHNICAL REPORT
TECHNICAL REPORT IEC TR 62066 First edition 2002-06 Surge overvoltages and surge protection in low-voltage a.c. power systems General basic information Surtensions de choc et protection contre la foudre
More informationCoordination of Surge protection devices
Coordination of Surge protection devices Design guide Surge arresters for commercial and industrial buildings Surge protection devices: how to choose them? coordination How to choose surge protection devices?
More informationHazardous Area Protection
Hazardous Area Protection Global Solutions in Hazardous Area Surge and Lightning Protection Intrinsic Safety When instrumentation is installed in a potentially explosive environment steps must be taken
More informationRM4LA32M liquid level control relay RM4-L V AC
Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A
Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 12 V - 2 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection
More informationPROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment
PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting
More informationRisk Assessment of Damages due to Lightning Discharges: A Case Study to a Telecommunication System in Singburi Province of Thailand.
Proceedings of the 2007 WSEAS Int. Conference on Circuits, Systems, Signal and s, Gold Coast, Australia, January 17-19, 2007 216 Risk Assessment of Damages due to Lightning Discharges: A Case Study to
More informationLIGHTNING AND SURGE PROTECTION
White Paper LIGHTNING AND SURGE PROTECTION Lightning and Surge Protection 01/20/17 1 of 7 www.murata.com APPLICATION NOTE: LIGHTNING AND SURGE PROTECTION Because wireless systems are typically located
More informationWhite Paper Surge Current Characteristics: 570 Hybrid Surge Protective Device
White Paper Surge Current Characteristics: 57 Hybrid Surge Protective Device Surge Current Characteristics: 57 Hybrid Surge Protective Device This document describes the surge current mitigation characteristics
More information/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*
surge arresters are intended for protection of electrical installations and devices against overvoltage effects, which may occur in atmospheric discharges and switching overvoltages. The main part of surge
More informationABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A
Characteristics regulated SMPS - 1 or 2 phase - 120..230 V AC - 24 V - 5A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply
More informationABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A
Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply
More informationApplication Note TAN MTL Surge Technologies. Surge protection for electrical power installations. Synopsis
MT Surge Technologies Surge protection for electrical power installations Synopsis This publication discusses the affects of surges and lightning induced overvoltages on ac power systems. The note will
More informationSurge Protection for Surveillance Systems
Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:
More informationIntroduction to Surge Protection
KL Automation Engineering Sdn Bhd Introduction to Surge Protection By Abu Bakar bin Yahya OBJECTIVE 1. To give awareness on lightning and surge effects. 2. To discuss on unexplained surge effect DEGRADATION
More informationEMC-Compatible Installation of the Electric Cabinet
EMC-Compatible Installation of the Electric Cabinet Introduction Malfunction and failure of an automated system due to electromagnetic influence can cause loss of production with high follow-up costs.
More informationInteliPro. Protection Relay for Parallel Applications. Technical Specification
InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the
More informationSurge Protective Device
SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous
More informationPowerPal Selectable Voltage 3-Amp Breadboard Power Supply (#32133)
Web Store: www.parallax.com Office: (916) 624-8333 Tutorials: learn.parallax.com Educator Hotline: (916) 701-8625 Sales: sales@parallax.com Sales: (888) 512-1024 Tech Support: support@parallax.com Tech Support:
More informationRetrofitting sewage plants with lightning and surge protection measures
904 Retrofitting sewage plants with lightning and surge protection measures A more efficient use of drinking water is growing in significance, especially against a backdrop of increasingly scarce drinking
More informationLIGHTNING PROTECTION FOR ROOFTOP PV PLANTS LIGHTNING & SURGE PROTECTION SYSTEM
LIGHTNING PROTECTION FOR ROOFTOP PV PLANTS LIGHTNING & SURGE PROTECTION SYSTE PREPARED BY : LIGHTNING PROTECTION CONCEPTS PONTINS REFERENCE : D00-RTPVP-05 ISSUE : B DATE : arch 07 Lightning Protection
More information1278 IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 21, NO. 3, JULY 2006
1278 IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 21, NO. 3, JULY 2006 Failure Risk Prediction Using Artificial Neural Networks for Lightning Surge Protection of Underground MV Cables Ángel L. Orille-Fernández,
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to