MARINE RADAR MARINE RADAR

Size: px
Start display at page:

Download "MARINE RADAR MARINE RADAR"

Transcription

1 MARINE RADAR

2 State-of-the-art Radar technology "Real-Time Radar" Relax operation and quick indication. a new Radar series from JRC incorporating the latest technology and user features. JRC JMA-5300 series Marine Radar is developed to enhance the radar performance, user-friendly operation and visibility, which meet radar & ATA/ARPA performance standards specified by IMO. The X and S-Band radar utilizing software-based digital signal processing with high performance computer-based technologies, offers the unique "Constaview " feature, providing radar of images in Real-Time Head-Up mode that rotates a radar echo image simultaneous to ship turning, "Target Enhancement Function (TEF) ", and target acquisition and tracking up to 100 using ATA/ARPA function.

3 JMA-5300 series - performance features Unique features The JMA-5300 series represents a major advance in Radar technology. The newly developed processing system gives users a range of new features not previously found on this class of radar. Chart Overlay Chart information can be combined with the radar image to present a complete overview of activity around the vessel. The radar image is combined with information from electronic charts. Own and other ship's tracks and AIS targets can be plotted and waypoints entered. This is a significant contribution to safe navigation. Target enhancement function(tef) Developed exclusively by JRC, TEF TM allows better identification of small and / or weak echoes. Equally, coastlines appear with improved definition. TEF TM works by adding pixels to targets displayed on the radar image and allows a vastly improved degree of distinguishing between targets. Sophisticated processing results in a proportional enhancement where the relative enhancement of smaller targets is greater than that applied to larger targets. The TEF TM is available in three levels-5x, 9x and 17x. Constaview All the information gathered by the radar is stored in the system, therefore switching from one view, i.e. North-up to Head-up or Range changes, instantly produces a new, complete radar image, reflecting the new selection. Targets that need to be closely followed can easily be reidentified on the new image. The Constaview represents a major contribution to safety and operational flexibility. Real-time Head-up mode Constaview Conventional Radar sweep Redrawing True Trails Constaview refreshes the image every 16mS. Despite heading changes trails are always reordered, displayed by memory. Relative Trails Traditional technology relies on several sweeps of the scanner to redraw the image. Trails are presented as relative.

4 JMA-5300 series - developed for maximum ease of use Full control - all radar operations can be carried out using the keyboard or on screen using a PS trackball. Compact and ultra flat keyboard. Dedicated buttons for major functions. Large, easy to use analog controls for EBL, VRM, GAIN, SEA and RAIN. Integrated trackball with connection to a PS/2 trackball. (option) The combination of push button and analog controls of the keyboard ensure a logical, precise operation. The newly developed processor technology ensures that selections are instantly displayed on the screen. The new JMA 5300 series radar also gives the user full control via the screen. An optional PS/2 trackball can be installed allowing the operator to use the on-screen menus for all radar operations. Cursor information Sensor information Own ship information ATA target information Signal processing information Menu area Alarm information Marker information Clear on-screen information Menu selections, via the Keyboard or Trackball are clearly shown on the display - allowing 'at a glance' interpretation of the radar image. A wide-screen option allows the entire display screen to be used for radar image presentation, whilst important information remains visible.

5 Display NWZ-147 Mass : Approx. 13.5kg (29.76lb) Keyboard NCE-7699 Processor NDC-1273 Mass : Approx. 1.3kg (2.87lb) 6ft Scanner NKE ft Scanner NKE ft Scanner NKE ft Scanner NKE-1075A Mass : Approx. 6kg (13.23lb) Mass : Approx. 37kg (81.57lb) Mass : Approx. 51kg (112.43lb) Mass : Approx. 53kg (116.84lb) Mass : Approx. 165kg (363.76lb)

6 Display format Range scale Scanner Output Transmitting frequency Polarization characteristic (-3dB width) Rotation speed Scanner Display Installation cable Option Pulse width Power consumption Transmitter / receiver switching Frequency conversion Tuning Environment Screen display Motion mode Processor EBL VRM Course display Chart display LCD Display unit Valid diameter Installation cable Operation unit Installation cable Connection box Environment Input voltage (Voltage range) NSK Unit ARPA unit -Professional version- 2 ATA unit -Common version- 2 Performance monitor 2 Inter-swich box AIS Interface unit Plotting Function unit AC Rectifier JMA JMA JMA JMA NKE ft 10kW H: 1.2, V: 20 Approx 24rpm 0.08uS / 2250Hz 0.25uS / 1700Hz, 0.5uS / 1200Hz, 0.8uS / 750Hz, 1.0uS / 650Hz Average 150W, Maximum 300W Raster scan PPI format NKE ft 25kW 9410 ±30MHz H: 1.0, V: 20 Circulator diode Microwave IC (Mic) Automatic Temperature: C, Humidity: C NDC-1273 Head-up / North-up / Course-up Relative motion(rm)with True trail / Relative motion(rm)with Relative trail / True motion 2-line/Bearing: (4-digit) 2-marker/Scale: (or 120.0) NM (4-digit) off / 15sec / 30sec / 1min / 3min / 6min / 10min / 15min / 30min / 60min / continuous C-MAP NWZ inch, color ( dots (SXGA)) more than 250mm 5m (between the processor and the display unit) NCE m (between the processor and the operation unit) NQE-3151 Temperature: C, Humidity: C, water-proof: IPX2 CFQ (Standard 20m) DC24V (DC For the scanner of JMA , AC power source is needed for the motor of scanner. 2 For compliance with IMO requirement, ARPA or ATA unit, and performance monitor are needed. Approx 24rpm NKE ft 25kW H: 0.8, V: uS / 2200Hz 0.20uS / 2200Hz, 0.4uS / 1400Hz, 0.8uS / 750Hz, 1.0uS / 650Hz Average 200W, Maximum 300W NCT-59 (built-in Processor unit) NCA-877W (built-in Processor unit) NCA-877 (built-in Processor unit) NJU-64 NQE (Max.4 radars) NQA-4250 (built-in Processor unit) NDB-34 (built-in Processor unit) NBA-3308 (100 / 110 / 115 / 200 /230 Vac) NKE-1075A 12ft 30kW MHz H: 1.9, V: 30 Approx 26 / 21rpm(60/50Hz) 0.07uS / 1900Hz, 0.20uS / 1900Hz 0.3uS / 1900Hz 0.6uS / 1100Hz 1.2uS / 570Hz Circulator+TRHPL CFQ (Standard 5m) (Standard 20m) DC24V (DC V AC230V(±10%)50/60Hz 1 1 Average 150W+200VA Maximum 150W+3kVA NJU-63 CAUTION Read the Instruction Manual before your use for safety in operation. Do not install this equipment in a place with water, wetness, vapor, dust and oily smoke. Otherwise, a fire, electric shock or failure may result. For the installation work for this equipment, request to JRC agents or dealers. The installation work done by any non-specialist personnel may result in an electric shock or failure. The specification and appearance of the equipment may be subject to change without notice. For further information, contact: Since 1915 URL Main Office: Nittochi Nishi-Shinjuku bldg. 10-1, Nishi-Shinjuku 6-chome Shinjuku-ku, Tokyo , Japan Telephone: Facsimile: Overseas Branches : Seattle, Amsterdam Liaison Offices : Taipei, Manila, Jakarta, Singapore, Hanoi, New York, Athens ISO9001 ISO14001 Certified

JAN-7201S/9201S ECDIS

JAN-7201S/9201S ECDIS ECDIS RMS * The photograph includes options. - Provide a smooth operating environment ensured by high-speed chart drawing. Conforming to the latest IMO performance standards with Marine Equipment Directive

More information

Black box radar High performance in a simple design.

Black box radar High performance in a simple design. Black box radar High performance in a simple design www.jrc.am Features The new high performance JMR-5400 radar significantly improves short range detection and discrimination of targets presented on high

More information

JMA-1030 Radar. the JMA-1030 is an easy to use radar that greatly supports your ship's handling by touch operation. since 1915

JMA-1030 Radar. the JMA-1030 is an easy to use radar that greatly supports your ship's handling by touch operation. since 1915 JMA-1030 Radar the JMA-1030 is an easy to use radar that greatly supports your ship's handling by touch operation 7-inch wide VGA color touch display Proprietary System-on-Chip technology Simple and intuitive

More information

GPS COMPASS JLR-20/JLR-30

GPS COMPASS JLR-20/JLR-30 GPS COMPASS JLR-20/JLR-30 enhanced performance and stability with JRC s new high visibility GPS COMPASS 5.7 inch high visibility LCD screen Fully integrated roll, pitch and rate of turn Wide range of display

More information

a highly accurate measurement tool that ensures stable speed data

a highly accurate measurement tool that ensures stable speed data Photo by Damen JLN-205Mk2 Speed log RMS a highly accurate measurement tool that ensures stable speed data 4.5-inch high brightness display Dual color LED backlight Various display modes Large characters

More information

JLR-7600/7900 (D)GPS navigator

JLR-7600/7900 (D)GPS navigator JLR-7600/7900 (D)GPS navigator RMS the JLR-7600/7900 delivers high accuracy performance while keeping operation easy 4.5-inch high brightness display Dual color LED backlight Proven sensors for high accuracy

More information

OMNI COLOR SCANNING SONAR JFS-6880SERIES

OMNI COLOR SCANNING SONAR JFS-6880SERIES OMNI COLOR SCANNING SONAR JFS-6880SERIES A Target Fish School Clear At a Glance!! Ship s Heading Mark (SHM) Cursor position Transducer unit operating state Information Area Fish quantity mark Fish school

More information

FMD-3200/FMD-3200-BB/FMD-3300

FMD-3200/FMD-3200-BB/FMD-3300 Operator's Guide The purpose of this guide is to provide the basic operation for this equipment. For more detailed information, see the Operator's Manual. FMD-3200/FMD-3200-BB/FMD-3300 All brand and product

More information

FICE-100 Ice Radar FOIL-200 Oil Radar

FICE-100 Ice Radar FOIL-200 Oil Radar FICE-100 Ice Radar FOIL-200 Oil Radar OPERATORS MANUAL Furuno Finland Oy www.furuno.fi TABLE OF CONTENTS FOREWORD 4 FICE-100 5 SYSTEM CONFIGURATION 6 1. GRAPHICAL USER INTERFACE (GUI) 7 1.1 Operating mode

More information

Operator's Guide FMD-3200/FMD-3200-BB/FMD-3300

Operator's Guide FMD-3200/FMD-3200-BB/FMD-3300 Electronic Chart Display and Information System (ECDIS) English Model Operator's Guide FMD-3200/FMD-3200-BB/FMD-3300 The purpose of this guide is to provide the basic operation for this equipment. For

More information

JAPAN RADIO CO., LTD.

JAPAN RADIO CO., LTD. no. JAPAN RADIO CO., LTD. http://www.jrc.co.jp/eng/index.html NAKANO CENTRAL PARK EAST, 10-1, Nakano 4-chome, Nakano-ku, Tokyo, 164-8570, Japan Tel : +81-3-6832-1816 / Fax : +81-3-6832-1845 / E-mail :

More information

Multifunction Navigation Displays

Multifunction Navigation Displays High Performance Multifunction Navigation Displays E80 8.4 Display E120 12.1 Display See Where Navigation Is Going TM 3-4 Multifunction Navigation Raymarine's most powerful multifunction navigation displays.

More information

ACONIS Advanced Control & Integration System

ACONIS Advanced Control & Integration System We Build a Better Future! Advanced Control & Integration System Hyundai ACONIS series offers the operator full integration of all control & automation function in combination with several systems such

More information

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi ) Cloud capable and communicating failsafe damper actuator for adjusting dampers in commercial HVAC applications. Failsafe Air Damper Size Up to approx. 45 sq. ft. Nominal Torque 180 in lb [20 NM] Power

More information

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC The midi LOGGER GL200 has evolved 10 channels compact data logger No only for temperature but also for voltage fluctuation measurement

More information

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version LevelOne KVM-0115/KVM-0117 15 / 17-inch LCD KVM Rack Console User Manual Version 1.0-1305 1 SAFETY INSTRUCTIONS 1. Please read these safety instructions carefully. 2. Please keep this User Manual for later

More information

Optical Spectrum Analyzer AQ6330. Full featured optical spectrum analyzer with compact and lightweight design

Optical Spectrum Analyzer AQ6330. Full featured optical spectrum analyzer with compact and lightweight design Optical Spectrum Analyzer AQ6330 Full featured optical spectrum analyzer with compact and lightweight design The AQ6330 is like no other optical spectrum analyzer you have ever seen. It is compact, lightweight

More information

Boating Tip #45: Chartplotters

Boating Tip #45: Chartplotters Boating Tip #45: Chartplotters As navigation technology has advanced, hand held GPS receivers have further evolved into chartplotters. Chartplotters graphically display a vessel s position, heading and

More information

Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide

Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide Страница 1 Back to Contents Page Specifications: Dell 1703FP Flat Panel Color Monitor User's Guide General Flat Panel Resolution Preset Display Modes Electrical Physical Characteristics Environmental Power

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

Simply point and choose

Simply point and choose Simply point and choose Examples of menu buttons: Center on Boat - The chart updates itself around the boat automatically. Quick Route - Quick and easy, make and activate a route from the boat s position.

More information

Specifications: Dell M782 Color Monitor User's Guide

Specifications: Dell M782 Color Monitor User's Guide Specifications: Dell M782 Color Monitor User's Guide General CRT Resolution Preset Display Modes Electrical Physical Characteristics Environmental Power Management Modes Pin Assignments Plug and Play Capability

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

MULTI FUNCTION DISPLAY MFD8/MFD12

MULTI FUNCTION DISPLAY MFD8/MFD12 MULTI FUNCTION DISPLAY MFD8/MFD12 User's Handbook The purpose of this guide is to provide the basic operation for this equipment. For more detailed information, see the Operator's manual. All brand and

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this User Manual / Installation Guide Model No. P150VR/P150VG Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet FEATURES APPLICATIONS MOTOR TESTING SOFTWARE DESCRIPTION Data Sheet High- Programmable Controller FEATURES Two Channels: Enable the unit to suppt up to two testing instruments with independent tandem configurations. Built-in Alarm System: F power, speed, tque,

More information

IS-3000-LS-ABB INFRARED SCANNER

IS-3000-LS-ABB INFRARED SCANNER IS-3000-LS-ABB INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES: SIMULATES ORIGINAL ABB PULSE OUTPUT AUTOMATIC GAIN CONTROL ADJUSTABLE SCAN ANGLE

More information

DM800 ECDIS. Solid Safe Simple. Danelec systems. Electronic Chart Display & Information System. Solid Safe Simple

DM800 ECDIS. Solid Safe Simple. Danelec systems. Electronic Chart Display & Information System. Solid Safe Simple Danelec systems DM800 ECDIS Electronic Chart Display & Information System A Revolution in Shipboard Service Servicing and repairing shipboard electronics can be time consuming and expensive. There are

More information

JUE-251 FleetBroadband

JUE-251 FleetBroadband FleetBroadband the second generation JRC FB250 brings a whole new level of communication to the bridge All-new above deck equipment (ADE) design Ready for all Inmarsat FB services Advanced integrated web

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT LINE SEIKI G0 SERIES ELECTRONIC P COUNTER or DIGITS ( Line LED Display) POWER SUPPLY (AC0 ~ 0V) PRESCALE FUNCTION KEY PROTECT, MEMORY DECIMAL POINT POSITIONING DUST / SPLASH PROOF G0 - G0 - MODEL SELECTION

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

BASELAYER CORE PA20 Power Module

BASELAYER CORE PA20 Power Module TM TM PA20 Power Module The CORE PC20 Power Module is a state of the art switchboard and UPS featuring modularized, critical components and delivers a configurable conditioned power supply. HIGHLIGHTS

More information

Practical and Compact!

Practical and Compact! Practical and Compact! 4ch Data Recorder 8ch Data Recorder Practical and Compact! Direct connection of Sound and Vibration Sensors 50 mm 210 mm 270 mm 8ch Data Recorder Sensitivity calibration of microphones

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.

More information

2.Installation of Scanner Unit > 2.4 PRECAUTIONS. Fig 2-14 The permissible bending radius of coaxial cable 2-38

2.Installation of Scanner Unit > 2.4 PRECAUTIONS. Fig 2-14 The permissible bending radius of coaxial cable 2-38 2.Installation of Scanner Unit > 2.4 PRECAUTIONS Fig 2-14 The permissible bending radius of coaxial cable 2-38 2.Installation of Scanner Unit > 2.4 PRECAUTIONS 2.4.3 Scanner installation position 1) Physical

More information

DM100 VDR. Voyage Data Recorder. Danelec systems Solid Safe Simple

DM100 VDR. Voyage Data Recorder. Danelec systems Solid Safe Simple DM1 VDR Voyage Data Recorder Danelec systems Solid Safe Simple New generation VDR with breakthrough SWAP technology TM IMO-compliant with the 214 VDR standards and beyond Discover the Danelec difference...

More information

OPERATION MANUAL LENS CONTROLLER

OPERATION MANUAL LENS CONTROLLER OPERATION MANUAL LENS CONTROLLER PTM-ZCB 100318 CONTENTS 1.INTRODUCTION 2.ATTENTION 3.ACCESSORY 1P 2P 2P 4.PART NAME AND FUNCTION 3P 5.GUARANTEE / SERVICE 6.SPECIFICATION 6P 7P 1.INTRODUCTION Please read

More information

MILLIMETER WAVE INDUSTRIAL DISTANCE SENSOR FMCW 94/10/X

MILLIMETER WAVE INDUSTRIAL DISTANCE SENSOR FMCW 94/10/X 46 Robezu str. LV-1004 Riga Latvia Phone: +371-7-065-100, Fax: +371-7-065-102 Mm-wave Division in St. Petersburg, Russia Phone: +7-812-326-5924, Fax: +7-812-326-1060 MILLIMETER WAVE INDUSTRIAL DISTANCE

More information

JUE-250 FleetBroadband

JUE-250 FleetBroadband JUE-250 FleetBroadband introducing pioneering solutions for the next-generation FleetBroadband communication service Upgrade path from JRC Fleet 33 Reliable broadband data and voice Dedicated compact solution

More information

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

UV LIGHT METER UVC-254

UV LIGHT METER UVC-254 UV LIGHT METER UVC-254 Storage for the " UV sensor " UV sensor is with extremely precise structure. Once don't use it, be sure to store it in the dry environment. For example, put the whole sensor including

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

IFR 6000 Transponder/DME Ramp Test Set

IFR 6000 Transponder/DME Ramp Test Set IFR 6000 Transponder/DME Ramp Test Set Product Specification DME pecifications A 5-minute warm-up period is required for all specifications. Output Reply Output Level Antenna Port Distance to UUT antenna

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

CyberView User Manual

CyberView User Manual CyberView User Manual RKP215-801 RKP217-801 RKP215-1601 RKP217-1601 2U Rackmount LCD monitor Keyboard drawer with KVM switch Version 2.0 20 March 2004 Table of Contents 1.0 General... 3 1.1 Unit Introduction...

More information

Angle encoder with Drive-CliQ Interface

Angle encoder with Drive-CliQ Interface Angle encoder with Drive-CliQ Interface 1 RU97 Series Absolute angle encoder Rotary enclosed type with Drive-CliQ interface and Functional Safety Magnetic functional principle Inner diameter : 20mm / 22mm

More information

TOPAZ 32 FULLY INTEGRATED PHASED ARRAY UT DEVICE WITH MULTI-TOUCH SCREEN PERFORMANCE AND PRODUCTIVITY REDEFINED

TOPAZ 32 FULLY INTEGRATED PHASED ARRAY UT DEVICE WITH MULTI-TOUCH SCREEN PERFORMANCE AND PRODUCTIVITY REDEFINED TOPAZ 32 FULLY INTEGRATED PHASED ARRAY UT DEVICE WITH MULTI-TOUCH SCREEN PERFORMANCE AND PRODUCTIVITY REDEFINED High-Performance Phased Array UT at Your Fingertips Feature Size (H W D) Weight Multi-Touch

More information

(EQUIPMENT ARRIVAL LIST DATED )

(EQUIPMENT ARRIVAL LIST DATED ) (EQUIPMENT ARRIVAL LIST DATED 05.11.16) Ref # SP/16/11/E7/47 Sr.No. PART NO 01 CYLINDER LINER (MAX WEAR 0.5 mm) 90302-41-142 03 Pcs. USED + GOOD 02 O-RING 90302-41-046 12 Pcs. 03 O-RING 90302-41-058 24

More information

VLT Micro Drive. Ready Set Go!

VLT Micro Drive. Ready Set Go! Despite its compact size and ease of installation, the VLT Micro Drive can deliver exceptional performance even in complex applications. 1 Well protected IP20 enclosure with NEMA/UL Type 1 optional; no

More information

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

Manual. Network Expansion Port 2 NEP-2. English.   Brands by Navico - Leader in Marine Electronics Manual Network Expansion Port 2 NEP-2 English www.lowrance.com www.simrad-yachting.com Brands by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain

More information

User Manual DUO BEAM/RG

User Manual DUO BEAM/RG User Manual DUO BEAM/RG Thank you for purchasing the DUO BEAM/RG Laser Show System. This manual is intended to help you to use the functions of the unit. It is suggested that you should refer to this instruction

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

DM100 S-VDR. Simplified Voyage Data Recorder. Danelec systems Solid Safe Simple

DM100 S-VDR. Simplified Voyage Data Recorder. Danelec systems Solid Safe Simple DM100 S-VDR Simplified Voyage Data Recorder Danelec systems Solid Safe Simple New generation S-VDR with breakthrough SWAP technology TM IMO-compliant with S-VDR standards and beyond Discover the Danelec

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module 6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger

More information

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global Ultra-minute Photoelectric Sensor EX-Z SERIES Conforming to EMC Directive No. 1 The World s in Compactness * Among photoelectric sensors with built-in amplifier, as of June 215 (survey by our company)

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Pen Vibration Meter Model VB400 Introduction Congratulations on your

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Unidrive M400 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M400 User Guide which is

More information

42 Stretched Outdoor Double-Sided Transit VMS, Landscape, 4 ft x 1 ft

42 Stretched Outdoor Double-Sided Transit VMS, Landscape, 4 ft x 1 ft NIADM-4949LC-SEA 42 Stretched Outdoor Double-Sided Transit VMS Specification 42 Stretched Outdoor Double-Sided Transit VMS, Landscape, 4 ft x 1 ft Model: NIADM-4949LC-SEA, Landscape, Double-Sided Tamper-proof

More information

High Accuracy, Easy Operation for 2D Code Reading

High Accuracy, Easy Operation for 2D Code Reading High Accuracy, Easy Operation for 2D Code Reading 2D Code Reading Sensor PD50 ARCT1B260E-1 '05.11 http://www.nais-e.com/vision/ Panasonic... the new name for Matsushita Electric Works, Ltd. Combination

More information

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet. Features. Applications. Description

MAGTROL. DSP6001 High-Speed Programmable Dynamometer Controller. DSP6001 Data Sheet. Features. Applications. Description Data Sheet High- Programmable Controller Features Two Channels: Enable the unit to suppt up to two testing instruments with independent tandem configurations. Built-in Alarm System: F power, speed, tque,

More information

Multifunction edger Me /

Multifunction edger Me / Multifunction edger Me 1200 /900 Multifunction edger Me 1200 The ME-1000 DESIGN+ Lens Edger, which had ushered in a new era of lens finishing as the world's first automatic 3-D drilling edger, has been

More information

DECT Signalling Test Unit PTW15

DECT Signalling Test Unit PTW15 DECT Signalling Test Unit PTW15 Support in installation and maintenance of DECT networks Main applications DECT coverage measurement (installation and test) DECT network control (maintenance and optimization

More information

VLT The general purpose drive. Phone: Fax: Web: -

VLT The general purpose drive. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE VLT 2800 The general purpose drive The pace-setter among general purpose drives The VLT 2800 series are among the smallest multi-purpose drives in the market, designed for

More information

FX1N JAPANESE SPECIFICATION UNITS

FX1N JAPANESE SPECIFICATION UNITS FX1N JAPANESE SPECIFICATION UNITS HARDWARE MANUA JY997D071A This manual contains safety information, associated manual listings, specifications and terminal layouts and wiring for Japanese specification

More information

Instruction Manual MINI CALIBRATOR MC-20

Instruction Manual MINI CALIBRATOR MC-20 Instruction Manual MINI CALIBRATOR MC-20 Introduction Thank you for purchasing the MINI CALIBRATOR MC-20. This manual contains operating, specifications and cautions, etc. Please ensure that you fully

More information

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit Pressure Switch CE0 NEW IR Communication type Pressure Switch Rev. Fluids/Gasses Utilizing Stainless Diaphragm Utilizes stainless steel diaphragm for use with a wide variety of pressure media Excellent

More information

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket Solid-state Timer Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms

More information

Interface Conversion Adaptor (DVI to LVDS) IA-573-A. User s Manual. Ver.1.02

Interface Conversion Adaptor (DVI to LVDS) IA-573-A. User s Manual. Ver.1.02 Interface Conversion Adaptor (DVI to LVDS) IA-573-A User s Manual Ver.1.02 Interface Conversion Adaptor (DVI to LVDS) IA-573-A User s Manual 2007.2 Ver.1.02 ASTRODESIGN,Inc Contents Contents... i Before

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions

More information

DSP7000 Series High-Speed Programmable Dynamometer Controllers DESCRIPTION

DSP7000 Series High-Speed Programmable Dynamometer Controllers DESCRIPTION Data Sheet Series High- Programmable Controllers DSP7001 - single channel - dual channel FEATURES DSP7001 Single Channel: Low cost and easy to use Dual Channel: Enables the support of two testing instruments

More information

Can eliminate static charge over an extensive range

Can eliminate static charge over an extensive range No.BK-P3 Static Electricity Removing Unit Ionizer Wide Area Fan Type Overhead Fan Type Can eliminate static charge over an extensive range Wide area fan type RoHS compliant product Overhead fan type Static

More information

X1DE-31U USB 3.5" Micro Floppy Disk Drive

X1DE-31U USB 3.5 Micro Floppy Disk Drive USB 3.5" Micro Floppy Disk Drive Features Introduction This material provides the information necessary to interface the X1 series micro floppy disk drives to floppy disk controllers, and provides all

More information

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p

Rackmount LCD Console - 1U - 17in Screen - US Keyboard p Rackmount LCD Console - 1U - 17in Screen - US Keyboard - 1080p Product ID: RKCOND17HDEU This 1U LCD console offers a space-saving solution for managing and monitoring your DVI or VGA servers and KVM switches

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. Please refer to the Unidrive M200 / M20 User Guide which is available to download from www.controltechniques.com/user

More information

HP Docking Station and HP Advanced Docking Station

HP Docking Station and HP Advanced Docking Station Overview HP Docking Station and HP Advanced Docking Station 1. Power button 5. Docking connector 2. Power light 6. Visual alignment indicator 3. Docking posts 7. Notebook eject button and docking light

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

Available for low voltage and high current High slew rate with 100A/μs

Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Kenwood TMI Corporation

More information

2301E ST Steam Turbine Control for Small Generator Applications

2301E ST Steam Turbine Control for Small Generator Applications 2301E ST Steam Turbine Control for Small Generator Applications Product Specification 03407 (Revision A, 12/2014) Applications The 2301E-ST is a steam turbine control with internal algorithms designed

More information

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to

More information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS... Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe

More information

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

User s Manual Model PBL100 Logic Probe IM E. 4th Edition User s Manual Model 701988 PBL100 Logic Probe 4th Edition Foreword Thank you for purchasing the PBL100 100 MHz Logic Probe (Model 701988). This user s manual describes the functions, operating procedures,

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Operating Instructions and Description of Instrument Function Prothermo NMT539

Operating Instructions and Description of Instrument Function Prothermo NMT539 BA01026G/08/EN/19.15 71308663 Products Solutions Services Operating Instructions and Description of Instrument Function Prothermo NMT539 Temperature Basic Device Layout of Prothermo NMT539 Prothermo NMT539

More information

12-Channel Thermocouple Datalogger

12-Channel Thermocouple Datalogger User Manual 12-Channel Thermocouple Datalogger Model TM500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech TM500 Thermometer,

More information

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER

DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER TM TELEPHONE AND LINE ANALYZER DPA 7000 PATENTS PENDING TELEPHONE AND LINE ANALYZER PATENTS PENDING The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering

More information