Application Guide. Fan Coil (FCU) Application Guide. VTR8000 Series Room Controllers. Control Performance Energy savings Better building management
|
|
- Julia Owens
- 6 years ago
- Views:
Transcription
1 Application Guide Fan Coil (FCU) Application Guide VTR8000 Series Room Controllers Control Performance Energy savings Better building management
2 Application Guide VTR8000 Fan Coil Controller 2 TABLE OF CTENTS VTR8300 and SCs Fan coil terminal equipment controllers 5 Cost-saving, energy-saving applications 6 VT8000 network ready communication adapters 8 VTR8300A VC3500E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wireless door switch 8 VTR8350A5000 -VC3404E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, dehumidification, 2-position valves 10 VTR8300A VC3504E5000: Heating/cooling with changeover sensor: 2-pipe fan coil unit with 3-speed fan and wirelesss window switch 12 VTR8350A VC3400E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan and dehumidification, 2-position valves 14 VTR8300A VC3514E5000: Heating/cooling: 2-pipe fan coil unit with 3-speed fan and fresh air damper, 2-position valves 16 VTR8300A5000 -VC3500E5000 -VC3300E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with slave relay pack 18 VTR8300A VC3504E5000: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, 2-position valves with wired window switch 20 VTR8300A VC3500E5000: Heating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wired door switch 22 Appendix A - Passive infra-red (PIR) motion detector cover specifications 25 Appendix B - option network wiring if communicating models are used 26 Appendix C - controllers occupancy sequence of operation schematic 26 Appendix D - SED Series - wireless door & window switch 27 Appendix E - VTR8300 controller & VC3000 relay pack 29 Dimensions of VTR8300 controller 31 Specifications 32
3 VTR8000 Fan Coil Controller 3 The perfect balance between simplicity and sophistication Improve guest experience and customer loyalty with unmatched design, interface and branding options February 2014 Application Guide
4 Application Guide VTR8000 Fan Coil Controller 4 PRODUCT & APPLICATI SELECTOR VTR8300 & Relay Pack Power Building Function Humidity Control Application Outputs / Inputs Controller Relay Pack Typical Application Line Voltage Commercial or Hospitality Yes 2 or 4 pipe, Up to 3 speed fan 1H/1C with Reheat VTR8350A0Axx SC3500E5045 Page: 38, 42 1H/1C with 4 inputs and reheat VTR8350A0Axx SC3504E5045 Page: 40, 44 1H/1C with 4 inputs reheat and occ. output VTR8350A0Axx SC3514E5045 Page: 44 No 2 Pipe, Up to 3 speed fan Yes 2 or 4 pipe, Up to 3 speed fan No 2 Pipe, Up to 3 speed fan Slave fan control only 1H/1C with pulsed reheat 1H/1C with pulsed reheat and 4 inputs 1H/1C with Reheat 1H/1C with 4 inputs and reheat 1H/1C with 4 inputs reheat and occ. output 1H/1C with pulsed reheat 1H/1C with pulsed reheat and 4 inputs VTR8300A0Axx SC3400E5045 Page: 42 VTR8300A0Axx SC3404E5045 Page: 38 VTR8350A0Axx SC3500E5045 Page: 36, 50 VTR8350A0Axx SC3504E5045 Page: 40, 48 VTR8350A0Axx SC3514E5045 Page: 44 VTR8300A0Axx SC3400E5045 Page: 42 VTR8300A0Axx SC3404E5045 Page: 38 3 fan outputs VTR8300A0Axx SC3300E5000 Page: 46
5 Application Guide VTR8300 Fan Coil Controller 5 VTR8300 AND SCS COIL TERMINAL EQUIPMENT CTROLLERS This new cost-effective solution for upgrading line-voltage fan coil unit thermostats requires only two components: the VTR8300 terminal equipment controller and the SC3000 relay pack. This solution allows existing line voltage wiring between the fan coil unit and temperature controller to be re-used, reducing overall costs and installation time. The SC3000 relay pack features an onboard universal voltage power supply and line-voltage relays which directly drive fractional horsepower fan motors and valves. This eliminates the need to install and wire costly pilot relays and transformers. Commercial interface (local override) Power Part Number Description Humidity PIR Cover Communication VTR8300A0Axx Stand-alone fan coil terminal equipment controller No No Stand-alone VTR8300A0Bxx BACnet fan coil terminal equipment controller No No BACnet VTR8300A0Pxx Wireless fan coil terminal equipment controller No No ZigBee Pro Wireless VTR8300A5Axx Stand-alone fan coil terminal equipment controller No Yes Stand-alone VTR8300A5Bxx BACnet fan coil terminal equipment controller No Yes BACnet VTR8300A5Pxx Wireless fan coil terminal equipment controller Yes Yes ZigBee Pro Wireless VTR8350A0Axx Stand-alone fan coil terminal equipment controller Yes No Stand-alone VTR8350A0Bxx BACnet fan coil terminal equipment controller Yes No BACnet VTR8350A0Pxx Wireless fan coil terminal equipment controller Yes No ZigBee Pro Wireless VTR8350A5Axx Stand-alone fan coil terminal equipment controller Yes Yes Stand-alone VTR8350A5Bxx BACnet fan coil terminal equipment controller Yes Yes BACnet VTR8350A5Pxx Wireless fan coil terminal equipment controller Yes Yes ZigBee Pro Wireless Transformer relay packs for fan coil units Power Part Number Description SC3500E5045 Transformer relay pack five relay fan outputs SC3504E5045 Transformer relay pack five relay fan outputs, and four outputs SC3514E5045 Transformer relay pack five relay outputs, smart VDC OCC output, and four inputs SC3400E5045 Transformer relay pack four relay outputs and smart VDC output SC3404E5045 Transformer relay pack four relay outputs, smart VDC output, and four inputs SC3300E5045 Transformer relay pack three slave fan outputs Wireless accessories for VTR8300 Series Power Part Number Description SED-DOR-P-5045 SED-WIN-P-5045 Wireless door switch Wireless window switch
6 Application Guide VTR8000 Fan Coil Controller 6 COST AND, ENERGY-SAVING APPLICATIS From hotels and hospitals to schools, retail, and commercial buildings, Schneider Electric offers a wide range of room control solutions for your building management needs. Whether retrofitting current systems with a more technologically advanced room controller or going green with a more environmentally friendly option, the VTR8300 Series is the ideal, cost-competitive solution. The VTR8000 Series room controllers can be equipped with an integrated passive infrared motion sensor for demand-based occupancy control that opens up new opportunities in smart energy management. Unparalelled design and customization Combine casings and covers to highlight or blend into any decor or architecture. Configure the touchscreen to create the perfect user experience and even show your brand. Occupancy sensing Equip your room controller with an integrated passive infrared motion sensor for demand-based occupancy control that raises your energy efficiency to a whole new level. Open communications Advance control of your building with truly open, integrated communications. Open protocol options include Zigbee Pro wireless and BACnet. Energy savings Save energy. Save money. With SE8000 Series room controllers you ll reduce energy cost without sacrificing comfort one bit. Easy to install Accelerate your return on investment by saving time and resources from the beginning. Our easy-to-install systems integrate into a new or existing building, with no requirement for costly, specialised labor. Temperature and humidity sensing Deliver efficient, measureable control. If you can measure it, you can control itproviding more precise occupant comfort and productivity.
7 VTR8000 Fan Coil Controller 7 Tailor its design to match the architecture of your buildings The control, comfort and energy savings of building automation with your brand at the forefront February 2014 Application Guide
8 Application Guide VTR8000 Fan Coil Controller 8 VTR8300A0AXX - SC3500E5045: HEATING/COOLING: 4-PIPE COIL UNIT WITH 3-SPEED, 2-POSITI VALVES WITH WIRELESS DOOR SWITCH Cooling Coil Heating Coil 2-Position Cooling Valve 2-Position Heating Valve SED-DOR-P-5045 Door Switch: SED-DOR-P-5045 VTR8300 SC3500E Refer to Schneider Electric Catalog for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: Door RUI1 R AutoMode C or F As per user. Default value = F RH disp OFF Pulsed Heating OFF Pipe No 4.0 Seq. Operat 2 = Cooling / Heating 4 pipes Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
9 Application Guide VTR8300 Fan Coil Controller 9 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied VTR8300 Controller SC3500E Relay Pack Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by Tx-Rx Tx/Rx To Fan Coil Unit (High Voltage Side) Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. S On a call for cool: Cooling valve will open to maintain room temperature. Heating valve is closed. On a call for heat: Heating valve will open to maintain room temperature. Cooling valve is closed. Wireless Door Switch: The wireless door switch will automatically toggle occupancy. See page 48 for more details. Typical Wiring Example for SC Relay Pack Brown - High Speed H Black - Live Power Orange - Connected to Black-Live Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. SC3500E Blue - Medium Speed Red - Low Speed Orange - Heating Valve Yellow - Cooling Valve M L V V For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
10 Application Guide VTR8000 Fan Coil Controller 10 VTR8350A0AXX - SC3404E5045: COOLING AND ELECTRIC HEAT: 2-PIPE COIL UNIT WITH 3-SPEED, DEHUMIDIFICATI, 2-POSITI VALVES Cooling Coil Electric Heat FA N VTR8300 SC3404E SSR SSR: Solid State Relay (Generic) Refer to Schneider Electric Catalog for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: RUI1 R AutoMode C or F As per user. Default value = F RH disp Pulsed Heating Pipe No 2.0 Seq. Operat 2 = Cooling with electric reheat Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
11 Tx / Rx 7 Vdc Power Supply Com RUI SCom WHITE Vac - 50/60 Hz RBI 2 1/2HP + 5A Max Comb. Amb. Temp. 50 o C SS BLACK RS LOW RED Heat- 1/2 HP MED BLUE Max Heat+ HIGH BROWN 5A COOL YELLOW Max STATUS Use copper conductors 75 o C min. only. Made in Canada Application Guide VTR8300 Fan Coil Controller 11 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by VTR8350 Controller Tx-Rx SC3404E Relay Pack Tx/Rx To Fan Coil Unit (Hight Voltage Side) Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. RUI 1 Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. S S On a call for cool: Cooling valve will open to maintain room temperature. Heating valve is closed. Dehumidification is enabled. RBI 2 On a call for heat: SS Electric heat will operate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. RS On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COOL mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. Heat - Heat + Typical Wiring Example for SC Relay Pack SSR Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor SC3404E5045 SC3404E Brown - High Speed Blue - Medium Speed Red - Low Speed Yellow - Cooling Valve Black - Live Power H M L V White - Neutral For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
12 Application Guide VTR8000 Fan Coil Controller 12 VTR8300A0AXX - SC3504E5045: HEATING/COOLING WITH CHANGEOVER SENSOR: 2-PIPE COIL UNIT WITH 3-SPEED AND WIRELESSS WINDOW SWITCH SED-WIN-P-5045 Heating/Cooling Coil VTR8300 SC3504E C/O Sensor Supply Sensor Optional PIR cover: COV-PIR-FCU-C Changeover Sensor: 10KOhm type 2 Changeover Sensor: 10K Ohm type 2. Supply Sensor: 10KOhm type 2 Supply Sensor: 10K Ohm type 2. Window Switch : SED-WIN-P-5045 Refer Window to Schneider Switch: Electric VWA5000W5045W. Catalog for valves and actuators. Refer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: Window RUI1 COS R AutoMode C or F As per user. Default value = F RH disp OFF Pulsed Heating Pipe No 2.0 Seq. Operat 0 = Cooling Only Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
13 Application Guide VTR8300 Fan Coil Controller 13 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by VTR8300 Controller Tx-Rx SC3504E Relay Pack Tx/Rx To Fan Coil Unit (Hight Voltage Side) Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. Occupied Override Mode: RUI 1 The system will revert to occupied mode for the duration determined by the ToccTime parameter. S S On a call for cool: If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. Heating valve is closed. RBI 2 SS On a call for heat: If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. RS Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. Typical Wiring Example for SC Relay Pack Wireless Window Switch: The wireless window switch will automatically lock out heating/cooling when window is opened. See page 48 for more details. Brown - High Speed Blue - Medium Speed H M Black - Live Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. SC3504E Red - Low Speed Yellow - Cooling Valve L V For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
14 Application Guide VTR8000 Fan Coil Controller 14 VTR8350A0AXX - SC3400E5045: COOLING AND ELECTRIC HEAT: 2-PIPE COIL UNIT WITH 3-SPEED AND DEHUMIDIFICATI, 2-POSITI VALVES Cooling Coil Electric Heater SSR: Solid State Relay (Generic) VTR8300 SC3400E SSR Refer to Schneider Electric Catalog for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: RUI1 R AutoMode C or F As per user. Default value = F RH disp Pulsed Heating Pipe No 2.0 Seq. Operat 2 = Cooling with electric reheat Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
15 Application Guide VTR8300 Fan Coil Controller 15 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by VTR8350 Controller Tx-Rx SC3400E Relay Pack Tx/Rx To Fan Coil Unit (High Voltage Side) Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. S Heat - Heat + SSR On a call for cool: Cooling valve will open to maintain room temperature. Heating valve is closed. Dehumidification is enabled. On a call for heat: Electric heat will operate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COOL mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. Typical Wiring Example for SC Relay Pack SC3400E Brown - High Speed Blue - Medium Speed Red - Low Speed Yellow - Cooling Valve H M L V Black - Live Power White - Neutral For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor.
16 Application Guide VTR8000 Fan Coil Controller 16 VTR8300A5AXX - SC3514E5045: HEATING/COOLING: 2-PIPE COIL UNIT WITH 3-SPEED AND FRESH AIR DAMPER, 2-POSITI VALVES Heating/Cooling Coil Fresh Air Supply Sensor Return Air C/O Sensor VTR8300 SC3514E Supply Sensor: 10K Ohm type 2. Changeover Sensor: 10K Ohm type 2. Refer to Schneider Electric Catalog for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: Window RUI1 COS R AutoMode C or F As per user. Default value = F RH disp OFF Pulsed Heating Occ Out Pipe No 2.0 Seq. Operat 0 = Cooling Only Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
17 Application Guide VTR8300 Fan Coil Controller 17 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied The occupancy output will open the fresh air damper to minimum position. VTR8300 Controller Tx-Rx SC3514E Relay Pack Tx/Rx Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by Unoccupied Mode: To Fan Coil Unit (High Voltage Side) Setpoints will revert to those defined by unoccupied heating and cooling. The fresh air damper will close. RUI 1 Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: S S RBI 2 If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. Heating valve is closed. SS On a call for heat: If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. RS OCC R Fresh Air Damper Relay Options Typical Wiring Example for SC Relay Pack BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. SC3514E Brown - High Speed Blue - Medium Speed Red - Low Speed Yellow - Cooling Valve Black - Live Power H M L V White - Neutral For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
18 1 Tx / Rx 2 7 Vdc Power Supply 3 Com SC3300E WHITE Vac - 50/60 Hz 1/2HP + 5A Max Comb. Amb. Temp. 50 o C BLACK LOW RED 9 Heat- 1/2 HP MED BLUE Max 10 Heat+ HIGH BROWN 5A COOL YELLOW Max STATUS Use copper conductors 75 o C min. only. Made in Canada 1 Tx / Rx 2 7 Vdc Power Supply 3 Com SC3500E WHITE Vac - 50/60 Hz 1/2HP + 5A Max Comb. Amb. Temp. 50 oc BLACK RED LOW 1/2 HP BLUE Max MED BROWN HIGH 5A COOL YELLOW Max ORANGE HEAT ORANGE Vac 10A Max Amb. Temp. 50 oc STATUS Use copper conductors Made in Canada 75 oc min. only. Application Guide VTR8000 Fan Coil Controller 18 VTR8300A0AXX -SC3500E5045 -SC3300E5045: HEATING/COOLING: 4-PIPE COIL UNIT WITH 3-SPEED, 2-POSITI VALVES WITH SLAVE RELAY PACK Cooling Coil Heating Coil SC3300E 2-Position Cooling Valve 2-Position Heating Valve Refer to Schneider Electric Catalog for valves and actuators. VTR8300 SC3500E Configuration parameter name Configuration settings PswrdSet 0 is factory set, range is: RUI1 R MenuScro AutoMode C or F As per user. Default value = F %RH disp OFF Lockout As per user. Default value = 0 No lock PulsedHt OFF Pipe No 4.0 SeqOpera 2 = Cooling / Heating 4 pipes Fan Menu 2 DHumiLCK %RH set As per user. Default value = 50%. Range = 30% to 95% DehuHyst As per user. Default value = 5%. Range = 2% to 20% DehuCool As per user. Default value = 100%. Range = 20% to 100% St-By TM 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc TM 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By HT 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By CL 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc HT As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc CL As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. Range = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal RS 0 F or C cal RH 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CPH Heat cph As per user. 4 to 8 CPH CoolNoNc NC HeatNoNc NC Fan Cont
19 Application Guide VTR8300 Fan Coil Controller 19 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. Heating valve is closed. On a call for heat: Heating valve will open to maintain room temperature. Cooling valve is closed. VTR8300 Controller Tx-Rx S SC3500E Relay Pack Tx/Rx To Fan Coil Unit (High Voltage Side) SC3300E Slave Relay Pack Tx/Rx To Fan Coil Unit (High Voltage Side) Options BACnet and Wireless communication models available (see Appendix B for network wiring). Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. Typical Wiring Example for SC Relay Pack SC3500E Brown - High Speed Blue - Medium Speed Red - Low Speed Orange - Heating Valve Yellow - Cooling Valve H M L V V Black - Live Power Orange - Connected to Black-Live Power White - Neutral For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
20 Application Guide VTR8000 Fan Coil Controller 20 VTR8300A0AXX - SC3504E5045: COOLING AND ELECTRIC HEAT: 2-PIPE COIL UNIT WITH 3-SPEED, 2-POSITI VALVES WITH WIRED WINDOW SWITCH Window Switch Heating/Cooling Coil C/O Sensor Supply Sensor Changeover Sensor: 10K Ohm type 2. Supply Sensor: 10K Ohm type 2. Window Switch: Generic Window Switch VTR8300 SC3504E Configuration parameter name Configuration settings PswrdSet 0 is factory set, range is: RUI1 R MenuScro AutoMode Window COS C or F As per user. Default value = F %RH disp Lockout PulsedHt OFF As per user. Default value = 0 No lock OFF Pipe No 2.0 SeqOpera Fan Menu 2 DHumiLCK 2 = Cooling with Electric Reheat %RH set As per user. Default value = 50%. Range = 30% to 95% DehuHyst As per user. Default value = 5%. Range = 2% to 20% DehuCool As per user. Default value = 100%. Range = 20% to 100% St-By TM Unocc TM 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By HT 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By CL 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc HT As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc CL As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type SptFunc TOccTime DoorTime Permanent Dual Stp or AttchStp As per user. Default value 2 hours. Range = 0 to 24 hours N/A deadband As per user. Default value 2.0 F ( 1.0 C ). cal RS 0 F or C cal RH 0 F or C Auto Fan Cool cph Heat cph CoolNoNc HeatNoNc Fan Cont AS or AS AD As per user. 4 to 8 CPH As per user. 4 to 8 CPH NC NC Refer to Schneider Electric Catalogue for valves and actuators.
21 Application Guide VTR8300 Fan Coil Controller 21 Sequence of operation and wiring Occupied Mode: VTR8300 Controller SC3504E Relay Pack Setpoints will revert to those defined by occupied Tx-Rx Tx/Rx Stand-by Mode (only available when PIR motion detector cover is used): To Fan Coil Unit (High Voltage Side) Setpoints will revert to those defined by stand-by Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. RUI 1 Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: S Window Contact S RBI 2 If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. Heating valve is closed. SS On a call for heat: RS If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. Wireless Window Switch: The window switch will automatically lock out heating/ cooling when window is opened. Typical Wiring Example for SC Relay Pack Brown - High Speed Blue - Medium Speed Red - Low Speed H M L Black - Live Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). Models available with factory installed PIR cover. Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. SC3504E Yellow - Cooling Valve V For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
22 Application Guide VTR8000 Fan Coil Controller 22 VTR8300A0AXX - SC3500E5045: HEATING/COOLING: 4-PIPE COIL UNIT WITH 3-SPEED, 2-POSITI VALVES WITH WIRED DOOR SWITCH Cooling Coil Heating Coil FA N Door Switch 2-Position Cooling Valve 2-Position Heating Valve Door Switch: Generic wired door switch. VTR8300 SC3500E Refer to Schneider Electric Catalog for valves and actuators. Configuration parameter name Configuration settings Password 0 is factory set, range is: Door RUI1 R AutoMode C or F As per user. Default value = F RH disp OFF Pulsed Heating OFF Pipe No 4.0 Seq. Operat 2 = Cooling / Heating 4 pipes Fan Menu 2 Deh. lockout Dehumidify As per user. Default value = 50%. Range = 30% to 95% Deh. hyster As per user. Default value = 5%. Range = 2% to 20% Deh. max cool As per user. Default value = 100%. Range = 20% to 100% Standby time 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc. time 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Standby heat 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) Standby cool 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc heat SP As per user. Default value = 62 F ( 17 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Unocc cool SP As per user. Default value = 80 F ( 27 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Max heating As per user. Default value = 90 F ( 32 C ). Range = 40 to 90 F ( 4.5 to 32.0 C ) Max cooling As per user. Default value = 54 F ( 12 C ). Range = 54 to 100 F ( 12 to 37.5 C ) Prop. band 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) T. Occup. time As per user. Default value 2 hours. Range = 0 to 24 hours Min. deadband As per user. Default value 2.0 F ( 1.0 C ). calibr. temp. 0 F or C calibr. humid. 0 F or C Auto Fan Funct AS or AS AD Cooling cph As per user. 4 to 8 CPH Heating cph As per user. 4 to 8 CPH Cooling Valve NC Heat Valve NC Fan Control
23 Application Guide VTR8300 Fan Coil Controller 23 Sequence of operation and wiring Occupied Mode: Setpoints will revert to those defined by occupied Stand-by Mode (only available when PIR motion detector cover is used): Setpoints will revert to those defined by stand-by VTR8300 Controller Tx-Rx SC3500E Relay Pack Tx/Rx To Fan Coil Unit (High Voltage Side) Unoccupied Mode: Setpoints will revert to those defined by unoccupied heating and cooling. Occupied Override Mode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. Heating valve is closed. S Door Contact On a call for heat: Heating valve will open to maintain room temperature. Cooling valve is closed. Door Switch: The door switch will automatically toggle occupancy. Typical Wiring Example for SC Relay Pack Brown - High Speed H Black - Live Power Orange - Connected to Black-Live Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). Models available with factory installed PIR cover. Remote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / universal input can be configured for a changeover sensor. SC3500E Blue - Medium Speed Red - Low Speed Orange - Heating Valve Yellow - Cooling Valve M L V V For 2 pipe applications use cooling valve yellow wire connection For electric reheat applications where current draw is above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve.
24 VTR8000 Fan Coil Controller 24 Energy savings for a healthy bottom line Increase the comfort of patients, visitors, and employees while reducing energy consumption with VTR8300 Series room controllers February 2014 Application Guide
25 Application Guide VTR8300 Fan Coil Controller 25 APPENDIX A - PASSIVE INFRA-RED (PIR) MOTI DETECTOR COVER SPECIFICATIS PIR cover sequence of operation Initially, the controller is in Stand-by mode. Stand-by setpoints are used at the controller. As soon as the PIR detects motion, the Occupancy status switches to Occupied and the Stand-By Time timer is reset. The Occupied setpoints are used. If no motion is detected in the room for the entire Stand-By Time duration (adjustable parameter), the room then switches to Stand-by mode and stand-by setpoints are used. While in Stand-by mode, if no motion is detected for the entire Unoccupied Time period (adjustable parameter), the room switches to Unoccupied mode and uses its Unoccupied setpoints. While in Stand-By or Unoccupied mode, any motion will switch the room back to Occupied mode. Typical Detection Pattern for PIR Lens Horizontal Angle (typical) Vertical Angle (typical) Meters (20 Feet) CENTER 6.1 Meters (20 Feet) 4.6 Meters (15 Feet) Meters (15 Feet) CENTER 6.1 Meters (20 Feet) Energy savings Typical Savings of 10-30% % 30% % % % Time of Day (EST) Typical Consumption PIR Thermostat Consumption Savings February % Saving Percentage The PIR can maximize your energy saving from 10-30% by relaxing temperature set points in unoccupied zones during scheduled periods. Energy Usage (KWh) 75 70
26 Application Guide VTR8000 Fan Coil Controller 26 APPENDIX B - OPTI NETWORK WIRING IF MUNICATING MODELS ARE USED BACnet communication wiring Wireless communication BACnet thermostat ref BACnet thermostat 2 BACnet thermostat ref + - ref Notes: - No communication wires needed Notes: - Wiring should be daisy chained - Respect polarity - If using 2 conductors shielded wires, connect the shield of each feed together on the back of the controller. LY ground the shield at one location. DO NOT connect the shield to the ref terminal. APPENDIX C - CTROLLERS OCCUPANCY SEQUENCE OF OPERATI SCHEMATIC Setpoints Unoccupied cool 26.5 C 80 F Stand-by cool Occupied cool Occupied heat Stand-by heat Unoccupied heat Movement detected - Stand-by timer reset 22 C 72 F Deadband Stand-by time Into Stand-by mode - Unoccupied timer reset 24.5 C 76 F Deadband 70 F 70 F 21 C 21 C Unoccupied time Into Unoccupied mode 62 F 16.5 C Next movement detected 66 F 19 C Deadband 22 C 72 F Time
27 Application Guide VTR8300 Fan Coil Controller 27 APPENDIX D - SED SERIES - WIRELESS DOOR & WINDOW SWITCH Wireless Zigbee Pro door & window switch Wireless door switches used with the local PIR cover provide advanced local occupancy routines allowing for increased energy savings during occupied hours without sacrificing occupant comfort. The wireless switches are only compatible with the VTR8300 Series Controllers. Wireless window switches are used to monitor exterior windows and or patio and balcony doors being opened or closed. This prevents unnecessary energy consumption by the tenants. Fan Coil Terminal Equipment Controllers with SED Series ZigBee wireless switches can be used in network ready mode with or without integration to a central management system to allow for advanced functions such as central reservation and occupancy functions. A combination of up to twenty SED Series door and or window switches can be used simultaneously with a single Fan Coil Terminal Equipment Controller. The SED Series switches are factory delivered with 2 AAA batteries and are ready to be installed, configured and used right out of the box. Due to the extremely small current consumption of the switches, the expected battery life is approximately 10 years and is equivalent to the battery shelf life. No tools are required for commissioning or servicing the door switch. A very simple interface with an onboard LED & hidden switch provides all the required functions for local interaction. Local information for battery life and connectivity (heartbeat) are provided at the Fan Coil Terminal Equipment Controller local display through the ZigBee wireless network. Each switch is factory supplied with a magnet, a locking security tamper proof screw and self tapping mounting screws. Model selection Window Switch Door Switch SED-WIN-P-5045 SED-DOR-P-5045 LED (switch side) Pull Tab Hidden Switch
28 Application Guide VTR8000 Fan Coil Controller 28 APPENDIX E - VTR8300 CTROLLER & SC3000 RELAY PACK Product overview The VTR8300 Fan Coil Controller offers a new cost-effective solution for upgrading line-voltage fan coil unit thermostats. The VTR8300 terminal Equipment Fan Coil Unit Controllers are available as BACnet MSTP or wireless ZigBee Pro networked models. No previous building automation training is required for the easy installation and commissioning process. Installation can be completed in approximately fifteen minutes, reducing costs and providing increased savings. The SC3000 Series Line Voltage Switching Transformer Relay Pack Controllers has been designed for silent control of typical high voltage fan coil device loads (90 to 277 VAC multi-voltages capable). It uses advanced microprocessor-based circuitry with a built-in transformer that eliminates all typical required peripheral components when automating a Fan Coil unit with traditional building automation systems. The SC3000 Series Line Voltage Switching Transformer Relay Pack(s) operate as slave unit(s) under the control of a single master VTR83XX Terminal Equipment Controller. A single VTR83XX Terminal Equipment Controller can control up to 10x SC3000 Series Relay Pack. The SC3000 Series Relay Packs are line-powered units. The extremely compact unit locally contains all the relay outputs for fan switching and valve control. Models are also available for extra monitoring / control inputs of the Fan Coil Units. Typical fan coil unit setup Typical Fan Coil Unit Electrical Cabinet H C C C Low Voltage Connections to SER8300 Controller Star topology Daisy chained topology Mixed daisy chained and Star topology
Fan coil (FCU) application guide
Fan coil (FCU) application guide SE7000 Series room controllers Control Performance Energy savings Better building management Table of contents Product & application selector... 4 Cost-saving, energy-saving
More informationVTR8300 User Interface Guide VTR8300 Room Controller Series
VTR8300 User Interface Guide VTR8300 Room Controller Series CONTENTS Home Screen Display 2 How to Enter Setup Screen 3 Setup Screen Display 3 Network Settings 4 ZigBee Network Settings 4 BACnet Network
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationRoom Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet
Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet Application specific room controller with customizable screen colors. The VTR8300 is a line-voltage
More informationSER8300 Room Controller
SER8300 Room Controller Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colors. The SER8300 is a line-voltage fan coil room controller
More informationRoom Controllers. SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers SC3000 Relay Pack The SC3000 is a relay pack for line-voltage fan coil units. The device is used with SER7300 and SER8300
More informationRoom Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers
More informationRoom Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack
Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers and screen colours. The SER8300 is a line-voltage fan coil terminal
More informationSmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationVTR8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications
VTR8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Home Screen Display 2 How to Enter Setup Screen 3 Setup Screen Display 4 ClockSettings 5 Schedule Settings
More informationRoom Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack
Compatible with SmartStruure solution SmartStruure Lite solution Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack Application specific controller with customizable covers
More informationSE7600E Series Application Guide
SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview
More informationViconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification
Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification General The VT76xxW series is designed for single-stage and multi-stage control of water source heat pumps with dedicated
More informationSE8300 User Interface Guide SE8300 Series Room Controller
1 SE8300 User Interface Guide Room Controller Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS HMI Display 2 How to Enter Setup Screen 3 Setup Screen Display 3 Schedule Menu 4 Clock Settings
More informationSE8300 Room Controller
SE8300 Room Controller Low Voltage Fan Coil Controller and Zone Controller Application Specific low voltage Room Controller with customizable covers and screen colors. Suitable for commercial and high
More informationSE7600E Series Application Guide
Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available
More informationCONTENTS. Installation Guide. PIR Ready VT7200 Series 24 VAC Low Voltage Zoning Terminal Equipment Controller
PIR Ready VT7200 Series 24 VAC Low Voltage Zoning Terminal Equipment Controller Installation Guide For Commercial HVAC Applications Ma y 3 rd, 2012 / 028-0190-R8 CONTENTS Installation 2 Location 2 Installation
More informationModbus Integration Integration for Modbus Functionality for VTR8300 Series
Modbus Integration Integration for Modbus Functionality for VTR8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS
More informationRoom Controller. SE8300 Low Voltage Fan Coil Controller and Zone Controller
Room Controller Low Voltage Fan Coil Controller and Zone Controller Application specific controller with customizable covers and screen colours. The is a low voltage fan coil terminal equipment controller
More informationSER8300 User Interface Guide SER8300 Series Room Controller
SER8300 User Interface Guide SER8300 Series Room Controller Commercial and Hotel/Lodging HVAC Fan Coil Applications Version 8 2 TABLE OF CONTENTS HMI Display 2 How to Enter Setup Screen 3 Setup Screen
More informationExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet
ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet DataSheet ev 1.12.307/4.0 June 14, 2018 Operating Sequence Standard Occupied During normal occupied
More informationVT8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller
1 User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller CONTENTS Home Screen Display 2 How to Enter Setup Screen 3 Setup Screen Display 4 ClockSettings 5 Schedule Settings 6 Occupancy
More informationThe Bard BrightStat Room Controllers
The Bard BrightStat Room Controllers Introduction Smart energy management has never been easier than with the BrightStat Room Controllers for Bard Air Conditioning and Heat Pump applications. Designed
More informationRS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units
NT10 Series Revision Date April 16, 2014 RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on RS
More informationNT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation on RS485 communication failure Retention of temperature set-point
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationSE8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications
SE8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications Version 8 2 HMI Display The below shows a typical user interface for the hospitality industry. The User HMI is configurable
More informationNT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat
NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationRoom controller STRA-17
Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control
More informationSEZ7000 Series. Wireless Commercial Zoning System
SEZ7000 Series Wireless Commercial Zoning System A cost-effective, scalabe zoning system for the commercial market that delivers unparalleled flexibility via the ZigBee communication protocol. SEZ7000
More informationRS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units
NT10 Series Issue Date February 21, 2016 RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units Features Ultra slim wall-mount unit to match any decor Supports standalone operation on
More informationExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet
ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet DataSheet ev 1.12.302/4.3 October 27, 2014 Operating Sequence Standard Occupied During normal occupied operation the display will
More informationVZ7000 Series. BACnet Commercial Zoning System
VZ7000 Series BACnet Commercial Zoning System A cost-effective, scalable zoning system for the commercial market that delivers unparalleled flexibility via the open BACnet communication protocol. VZ7000
More informationTF243 Series Digital Thermostat Fan Coil Unit Control
TF243 Series Digital Thermostat Fan Coil Unit Control Features SPECIFICATION DATA General The TF243 series digital thermostat is designed for 3-speed fan and modulating valve control in a fan coil system,
More informationVZ7260X5X00W BACnet Zone Room Controller. Installation Guide. April 2017
VZ7260X5X00W BACnet Zone Room Controller Installation Guide For Commercial Zoning S ystems April 2017 CONTENTS Installation 2 Location 2 Installation 2 Theory of Operation 3 Features and benefits overview
More informationMarch 13 th, 2012 / R2
VZ7260X5X00B BACnet MS-TP Zone Terminal Equipment Controller Installation Guide For Commercial Zoning Systems March 13 th, 2012 / 028-0328-R2 CONTENTS Installation 2 Location 2 Installation 2 Theory of
More informationField selectable application type and room module series, via dip-switches on controller
TUC03 Plus Configurable Terminal Unit Controller Product bulletin The TUC03 Plus configurable Terminal Unit Controller is specifically designed to provide an improved BACnet integration. It allows the
More informationVTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller
BACnet Integration Terminal Equipment Controller Commercial and Lodging HVAC Applications BACnet CONTROLLER 2 BACnet Integration Manual VTR8300 and VT8300 series Protocol Implementation Conformance Statement
More informationSER8300 / SE8300 Series BACnet Integration Terminal Equipment Controller
1 BACnet Integration Terminal Equipment Controller Commercial and Lodging HVAC Applications BACnet CONTROLLER 2 BACnet Integration Manual SER8300 AND SE8300 SERIES PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT
More informationSER8300 Series Line Voltage Room Controller with Optional PIR Sensor Installation Guide
Line Voltage Room Controller with Optional PIR Sensor Commercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 3 Location 3 Installation 3 Terminal, Identification and Function 4 Communication
More informationSEZ7260X5x45B Installation Guide for BACnet MS/TP Zone Controller
SEZ7260X5x45B Installation Guide f BACnet MS/TP Zone Controller CONTENTS Installation 2 Location 2 Installation 2 Typical Applications 4 Main outputs wiring 5 Wiring examples 8 CO2 Sens wiring 8 Configuring
More informationSmartStruxure Lite solution Get Control. Get Efficient. Get Value.
SmartStruxure Lite solution Get Control. Get Efficient. Get Value. Solution Overview Small Building Systems SE7000 series The one that started it all. The Room controller: Sensor + HVAC control application
More informationRCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater
revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended
More informationSuitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.
TUC03 Configurable Terminal Unit Controller Product Bulletin The TUC03 Configurable Terminal Unit Controller is designed specifically to provide direct digital control of terminal unit applications with
More informationFCU-MULTI Modbus Fan Coil Unit Controller
Product Sheet CT2.61 Controller Type FCU-MULTI FCU-MULTI Modbus Fan Coil Unit Controller FCU-MULTI is completely stand-alone operating room controller designed for room heating, cooling, ventilation, lighting
More informationSE8000 Series BACnet Integration Terminal Equipment Controller. Commercial and Lodging HVAC Applications
BACnet Integration Terminal Equipment Controller Commercial and Lodging HVAC Applications 2 SER8300 AND SE8300 SERIES PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (PICS) Vendor Name: Schneider Electric
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More informationExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet
ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet DataSheet ev 1.12.307/4.0 Jun 20, 2018 Operating Sequence Standard Occupied During normal occupied operation the display will show
More informationRS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output
NTAF Series Issue Date March 1, 2018 RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output Features Ultra slim wall-mount unit to match any décor Supports Modbus RTU protpcol Supports
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationRCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs
revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.
More informationRCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs
revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan
More informationBACnet Product Overview
BACnet Product Overview Comfort and energy-saving of a HVAC system are all about control. With networking devices, you can monitor and control your equipment via a communication system anywhere and anytime
More informationTAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta
TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one
More informationSE8000 Series BACnet Integration
SE8000 Series BACnet Integration BACnet Integration for SE8000 Series Room Controller BACnet CONTROLLER Version 4 2 Table of Contents SE8000 BACnet Compatibility Specifications 3 Object Properties 4-8
More informationRCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs
revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint
More informationVTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller
BACnet Integration Terminal Equipment Controller Commercial and Lodging HVAC Applications BACnet CONTROLLER 2 BACnet Integration Manual VTR8300 AND VT8300 SERIES PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT
More informationSubmittal Data Sheet intelligent Touch Manager DCM601A71
For use with the following VRV Models: FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ, VAM For use with the following Daikin SkyAir Models: FAQ, FBQ, FCQ, FHQ, FTQ Capacity:
More informationBACnet Integration Manual September 1, 2010
PIR Ready VT7200 & VT7300 Series 24 Vac Fan Coil and Zoning Thermostats For Commercial and Lodging HVAC Applications BACnet Integration Manual September 1, 2010 1 VT7200X Series Product Overview The VT7200
More informationRDF Series Room Temperature Controllers
Document No. 19-49 RDF Series Room Temperature Controllers Product Description Room Temperature Controllers with LCD for twopipe (with and without an electrical heater) and fourpipe fan coil units. Installation
More informationCommunicating Thermostats. Add More Flexibility to Building Automation with. Communicating Thermostats
Communicating Thermostats Add More Flexibility to Building Automation with Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,
More informationHLS34 Modbus FCU/VAV Controllers installation instructions
HLS34 Modbus FCU/VAV Controllers installation instructions The HLS34 is specifically designed for individual room temperature and zone control applications. The controllers have built-in RS-485 channel
More informationFOCUS GUIDE VAV ZONE CONTROLLER. Configuration Guide for ProLon Focus Software
FOCUS GUIDE VAV ZONE CONTROLLER Configuration Guide for ProLon Focus Software www.proloncontrols.com info@proloncontrols.com 17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV. 6.2.0 PL-FOC-VAV-C/F-EN
More informationCONTROLLER INSTALLATION OPERATION & QUICK START
CONTROLLER INSTALLATION OPERATION & QUICK START Controller: 8403-066 ECU Series Controller Manual: 2100-559 Supersedes: NEW File: Tab 19 Date: 05-02-11 Page 1 of 6 TABLE OF CONTENTS Installation Note...
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationSTRA-17 Room controller. Installation and maintenance manual. Content
Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8
More informationRC-CDTO. Pre-programmed room controller with display, communication and three-point control
revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control
More informationVT8300 Room Controller
VT8300 Room Controller Low Voltage Fan Coil Controller and Zone Controller Application Specific low voltage Room Controller with customizable covers and screen colors. Suitable for commercial and high
More informationExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV
ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV DataSheet ev 1.12.302/4.1 June 26, 2018 Operating Sequence Standard Occupied Thermostat occupancy can be set from a
More informationApplication program: description and examples
F a n C o i l U n i t C o n t r o l l e r F a n C o i l 4 9 5 5 1 Application program: description and examples Woertz AG Electrotechnical accessories, installation systems Hofackerstrasse 47, P.O. Box
More informationBACnet Integration Manual ITG-VWG-50-BAC-E01.doc ( R1 Issue Date: January 10 th, 2012)
6/ VWG-50 BACnet Integration Manual Viconics Wireless Gateway BACnet Integration Manual ITG-VWG-50-BAC-E01.doc (028-6039 R1 Issue Date: January 10 th, 2012) 1 Product Overview The VWG-50 and related wireless
More informationIntroduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers
Wireless Sensor CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-583-01 6/2/2017 Verify that you have the most current version of this
More informationCONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE
Catalogue 207 CONTENTS CONTROLLERS... 4 room controllers... 5 room units... 29 control units... 24 PRODUAL 3 CATALOGUE T U R KU I C T C ON T R OL L E R S Multifunctional controllers for optimal performance
More informationPre-programmed room controller with display and communication
revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling
More informationAndover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator
Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware
More informationUnderfloor Controllers
Price Underfloor Controllers work with the entire line of Price Diffusers and Terminal Units. The whole system can be easily integrated with plug-and-play connections and BACnet communication. With a full
More informationMeasure & Control Temperature & CO2 levels with analog & digital I/O
MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature
More informationTLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.
TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal. Features Temperature control for 2-pipe and 4-pipe fan coil systems.
More informationAndover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator
Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.
More informationTEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications
TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications Product Bulletin TEC2647Z-3, TEC2647Z-3+PIR, TEC2664Z-3 The technologically advanced TEC Zoning Control System provides
More informationPre-programmed room controller with display and communication
revision 10 2017 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling
More informationInstallation Guide. VZ7656F1000B BACnet MS-TP RTU Terminal Equipment Controller with Modulating Heat. February 2017 /
VZ7656F1000B BACnet MS-TP RTU Terminal Equipment Controller with Modulating Heat Installation Guide For Commercial Zoning S ystems February 2017 / 028-0324-02 CONTENTS Installation 2 Location 2 Installation
More informationFeatures BACnet/IP over Wi-Fi, BACnet MS/TP, Delta LINKnet communication. EnOcean wireless for zone-level control, including sensors and outputs
Wireless BACnet Thermostat: ezntw Description The ezntw is a fully programmable thermostat equipped with EnOcean wireless connectivity and onboard Wi-Fi option. Featuring a standard temperature sensor
More informationFirmware Upgrade Release Notes. Release Notes for VT8000 Series Room Controllers
Firmware Upgrade Release Notes Release Notes for VT8000 Series Room Controllers 2 VT8000 Series Room Controllers Release notes are configured to Firmware Version 1.6.2, effective June 5, 2017. Information
More informationSEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS
SEZ7656E1045B Installation Guide f BACnet MS/TP RTU Terminal with IAQ Control CONTENTS Installation 2 Location 2 Installation 2 BACnet System Overview 3 Terminal, Identification and Function 4 Wiring 4
More informationRichmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green
Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01
More information75F Smart VAV with Reheat
A unique system-wide approach to maximizing performance PRODUCT OVERVIEW The wireless control solution reduces install cost, improves energy efficiency, and introduces remote control and diagnostic capabilities
More informationDesigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies
s Desigo RXA Room controllers without bus communications Range overview CA2S3880en_01 2012-08-30 Building Technologies Desigo TM RXA Room controllers without bus communications Contents Desigo RXA......
More informationMANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION + SERVICE Price Intelligent Controller PIC Series v400 Issue Date: 12/18/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General...1 Installing
More informationModular Room Control (MRC) Series Expansion Board
Installation Instructions Issue Date December 13, 2002 Modular Room Control (MRC) Series Expansion Board Application The Modular Room Control (MRC) system has the ability to expand its input/output capabilities
More informationRCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.
revision 01 2015 RCF230CTD Communicating room controller for fancoil applications with outputs for two thermal or one 3position actuator or function for an electric heater RCF230CTD is intended to control
More informationVZ7656F1000W Zigbee Wireless RTU Terminal Equipment Controller with Modulating Heat. Installation Guide
VZ7656F1000W Zigbee Wireless RTU Terminal Equipment Controller with Modulating Heat Installation Guide For Commercial Zoning S ystems Januar y 10 th, 2012 / 028-0325-R1 CONTENTS Installation 2 Location
More informationMicroprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.
HTC-DIGITAL-LCD Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication. Features Use Australian Made and designed LCD 2 X 16 Character Backlit Display Five Programmable
More informationSK Installation Instructions
Guestroom HVAC Energy Management System SK200-001 Installation Instructions GENERAL SYSTEM COMPONENTS INTRODUCTION The S200 series hospitality HVAC Energy Management (HEM) System is specially designed
More informationSmart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating
Smart heating system with wireless thermostats & smartphone control for every room Get the most out of any water based underfloor heating DETAILED OVERVIEW Control the heating in your home from anywhere.
More informationAndover ContinuumTM Infinet II
Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,
More informationMANUAL INSTALLATION. Multi-Variable Monitor. MVM Series. Issue Date: 02/07/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Multi-Variable Monitor MVM Series Issue Date: 02/07/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General...1 MVM Specifications...1 Included
More informationCDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)
Product sheet SN1.401 Type CDR-RH CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers) CDR-RH sensors are designed to detect carbon dioxide concentration, relative humidity and temperature
More information