Composed by 3 partners: Polesso, Huang and Bet; Started manufacturing OEM power supplies for computers.
|
|
- Sheila Hunt
- 6 years ago
- Views:
Transcription
1
2 ABOUT US Established in 1984 (São Paulo Brazil); Composed by 3 partners: Polesso, Huang and Bet; Started manufacturing OEM power supplies for computers. 2
3 CORE BUSINESS Design and production of: Power supplies; Energy systems with remote management; OEM telecom cabinets; Fiber Optical products and solutions; Services (installation, start up process, technical support, training, i repair, integration i and tests); Hybrid energy solutions and clean energy. 3
4 APPLICATIONS Telecom; Voting, Banking and Commercial Automation; Computers; Industrial. 4
5 OPERATIONS 5
6 COMPANY 60 high trained employees with very low turnover (12 at R&D Department); Outsourcing process in Brazil (150 employees) and China (up to 500 employees); Automatic testing system for main products. Quality System (ISO 9001:2008) 6
7 MAIN ADAVANTAGES Large experience at infrastructure products for Telecom; Own technology; Flexibility to customize products even at low quantity; Quick service in the field; Permanent support. 7
8 MAIN COSTUMERS 8
9 PRODUCTS OEM Power Supplies; Stand Alone Rectifier; Rectifier Units; Control Units; Rectifier Systems; Distribution Shelves; DC/DC Converter Systems; OEM Indoor and Outdoor Cabinet Solutions; Optical Products; Remote Power Feeding (under development); Converters for Hybrid Energy Solutions (under development); Solar Inverters (under development). 9
10 OEM PROJECTS Customized AC/DC & DC/DC SMPS for many applications; Diversified layouts (open frame, enclosed, DIN rail, rack mount, ); Designs to meet Internationalrequirements requirements (safety, EMIand EMC); Special circuits (Ex: O Ring MOSFETs for redundant supply). 10
11 STAND ALONE RECTIFIER SE2001/08 ( 48V/15A) 19 /1U shelf; Universal input (90Vac 260Vac); Adjustable output voltage (45Vdc 58Vdc); Maximum output current: 15A (Vin>180Vac) or 10A (90Vac<Vin<180Vac); Battery and 2 load thermal breakers; LVBD circuit; DC voltage and current meter (display); Wide temperature operation range ( 5 C to 70 C); ANATEL certification ( ). 11
12 RECTIFIER UNIT Suitable for 1U and 3U height power shelf; Universal input (90Vac 260Vac); Adjustable output voltage (45Vdc 58Vdc); Output current: 15A (Vin>180Vac) or 10A (90Vac<Vin<180Vac); Up to 90% of efficiency; Hot swap; Load sharing, suitable for redundant operation (N+1); Wide temperature operation range ( 5 C to 70 C); 900A 0048/01 ANATEL certification ( ). 48V/15A 12
13 RECTIFIER UNIT Suitable for 1U and 3U height power shelf; Universal input (90Vac 260Vac); Adjustable output voltage (45Vdc 58Vdc); Output current: 25A (Vin>180Vac) or 10A (90Vac<Vin<180Vac); Up to 95% of efficiency; Hot swap; Load sharing, suitable for redundant operation (N+1); Wide temperature operation range ( 5 C to 70 C); 1500W 0048/01 Comply with ANATEL requirements. Under Development 48V/25A 13
14 RECTIFIER UNIT High efficiency i (>96%); 1U hot swap module; Up to 4 units in 19 power shelf width; Digital control; Universal input (90Vac 260Vac); Adjustable output voltage (45Vdc 58Vdc); Maximum output power: 3000W (Vin>185Vac); Maximum output current: 48Vcc; Load sharing, suitable for redundant operation (N+1); Widetemperature operation range ( 5 C to 70 C); ANATEL certification ( ). 3000W 0048/01 48V/3000W 54Vcc 14
15 CONTROL UNIT USCC/19 1U hot swap module; Display (LCD) and keypad for local navigation; Battery management (float voltage compensation with temperature, tests, LVD, etc.); Up to 4 external alarm inputs; User configurable remote alarms; Controls up to 6 DC fans; RS232 Interface; Access control (RFID reader and electromagnetic lock control); o SNMP agent (optional) for remote reading or control; Event records. OPTIONAL ETHERNET CONVERTER (Installed inside of the Control Unit) 15
16 CONTROL UNIT 3U hot swap module; Display (LCD) and keypad for local navigation; Battery management (float voltage compensation with temperature, tests, LVD, etc.); Up to 4 external alarm inputs; User configurable remote alarms; Suitable to +24V or 48V systems; Controls up to 9 DC fans; RS232 Interface; SNMP agent (optional); Event records. USCC/18 OPTIONAL ETHERNET CONVERTER (Installed inside of the Control Unit) 16
17 CONTROL UNIT 1U hot swap module (with automatic vertical / horizontalposition operation); Color dot matrix LCD (128 x 128 pixel) and keypad for local navigation; Battery management (tests, LVDs, datalogs, voltage and current imbalance, etc.); Up to 8 external alarm inputs; User configurable remote alarms; Suitable to +24V or 48V systems; Controls up to 9 DC fans; Web server and SNMP agent (built in); Remote reading and control; Event, test, average, min. and max. system measurement records; Efficiency mode operation; Access control (RFID reader and electromagnetic lock control). USCC/20 17
18 RECTIFIER SYSTEM SR30A/ 48V 1U/19 power shelf; Redundant operation (900W + 900W); DC load distribution (3 mini breakers); Battery mini breaker; LVBD circuit; Hot swap connection (rectifier and control unit); Complete energy and infrastructure management; Local operation by keypad or computer (RS232); Ethernet interface (optional); Suitable for outdoor cabinet application; Wide temperature operational range ( 5 C to 70 C); ANATEL certification ( ). 18
19 RECTIFIER SYSTEM SR60A/ 48V 3U/19 power shelf; Redundant operation (3 x 900W + 1 x 900W); DC load distribution (6 breakers); 2 battery breakers; LVD circuit; Hot swap connection (rectifier and control unit); Complete energy and infrastructure management; Local operation by keypad or computer (RS232); Ethernet interface (optional); Suitable for outdoor cabinet application; Wide temperature operational range ( 5 C to 70 C); ANATEL certification ( ). 19
20 RECTIFIER SYSTEM TELECOM RECTIFIER SYSTEMS SR100A...SR2400A ( 48Vdc) 4 Rectifier Units ( 48V/3000W) )p per shelf (19 /1UH); Up to 2 power shelves (144kW/12UH); 1ф or 3ф AC input power sources; DPS protection; Allow sequential start up; CAN and Ethernet interfaces; Include battery and load distribution; Wide temperature operational range ( 5 C to 70 C); ANATEL certification ( ). Under development. 20
21 DISTRIBUTION SHELVES Customized AC or DC distribution units; Battery and load breakers or fuses; LVD circuit; AC breakers; AC or DC service outlet; Mains/Generator switch; Supervisory circuits; AC surge protection (MOV); Fan tray with control and supervisory circuits. DC DISTRIBUTION AC DISTRIBUTION FAN TRAY 21
22 DC/DC CONVERTER SYSTEMS Suitable for 3U height power shelf; Up to 5 modules in 19 power shelf width; Available on: o +24V/ 48V (800W/Module) o 48V/+24V (1000W/Module) Hot swap connection; Load sharing, suitable for redundant operation (N+1); Widetemperature operation range ( 5 C to 60 C). 22
23 INDOOR CABINETS Open and closed racks; Customized layouts; layouts Complete energy solutions; Energy and infrastructure management; Integration of telecom devices. devices 23
24 OUTDOOR CABINETS Cabinets for pole or ground installation; Customized layouts; Complete energy solutions; Energy and infrastructure management; Thermal solutions (double wall, cooling filters, heat exchanger, air conditioning, etc.); Environment tests at recognized laboratories (temperature, IP, salt spray, etc.); Integration of telecom devices. 24
25 FIBER OPTICAL PRODUCTS Outdoor and Indoor Optical Distribution Frames ; Racks and columns suitable to GPON room; Optical cables, connectors and splitters with ANATE L certification; Fiber cable assemblies with connectors according to costumer specification. 25
26 REMOTE POWER FEEDING Voltage Mode < > Central Up to 16 DC/DC converter modules ( 48V/±190V) with Monitoring Unit and Fan Tray at 3U/19 power shelf; Hot swap module (2 x 100VA); Web Browser, SNMP and USB; Comply with IEC safety standard; Safety start up; High efficiency (> 92%); Each central converter isable to feed one remote converter (wedding). Under development. Remote Up to 8 DC/DC converter modules (±190V/ 48V) per 19 /1UH; Hot swap module (2 x 85W ); Comply with IEC safety standard; Management of 3 inputs; Input reverse polarity protection; High efficiency (> 92%); Optional battery backup input for repair purpose; Recommended distance: up to 4km (45W+45W). 26
27 HYBRID ENERGY SOLUTIONS Under development. 27
28 GREEN ENERGY SOLAR INVERTERS Single phase and on grid solar inverters (transformless); Available on 1500W, 3000W and 4600W; MPPT efficiency over 99.5%; TDHi less than 5%; Comply with ABNT NBR 16149, ABNT NBR and ABNT NBR IEC
29 Contacts: Technical: Shelters: Commercial: Field Support: Web: 29
24/48V Battery Bank Ah High Cycling Long Life
Outdoor Power Cabinets, 48V DC Free Cooled with Combined Air-Con. PreFactory assembled with 19 inch Power sub rack, 2 or 4 battery Shelf s, 3U DCAC Panel combined with rectifiers 2U or 4U Power Module
More informationPRODUCTS AND SERVICES. At a glance
PRODUCTS AND SERVICES At a glance ELTEK DEUTSCHLAND GMBH Eltek Deutschland is a full-range provider of protected power supplies for the telecom, renewable and OEM power industries and industrial applications.
More informationENERGY THROUGH THE POWER OF TRADITION. Company Profile Marketing & Sales Division
ENERGY THROUGH THE POWER OF TRADITION Company Profile 2015 Marketing & Sales Division MARKET APPROACH : In order to exploit effectively the opportunity of potential market, due to competitive environment,
More informationMSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range
MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS
ULTRA-COMPACT 48V, 4V and 1V INTEGRATED DC POWER SYSTEMS RU 1 DISTRIBUTION & CONTROLLER SECTION RECTIFIER SECTION LVD7//EEC KEY FEATURES Compact, RU High Fully Integrated System Hot-Swap Rectifier Modules
More informationPOWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS
POWERING TECHNOLOGY Reliably powering your business. Solving your power needs. DC POWER SYSTEMS P O W E R I N G T E C H N O L O G Y UNIPOWER Systems today incorporates products from the former Power-One
More informationAC-DC Converter RECE K21
Thanks to the variety of modules available, the RECE3200-230-48-K21 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter
More informationGUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & Battery -48VDC 500A 26.8kW
GUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & -48VDC 500A 26.8kW Efficiency [%] LVD2006/95/EC EMC2004/108/EC ROHS2011/65/EU KEY FEATURES >96% Efficiency Rectifiers 500A
More informationUPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications
INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,
More informationAC-DC Converter REC K10
Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationMP7. Uninterruptible Power Supply
Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationSLI 15 INVERTER SERIES, 1500 W
SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R MP7
Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationAC-DC Converter REC /60-K20
Thanks to the variety of modules available, the REC3200-230-48-K20 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter
More informationPEM Faults and Blower Failures
CHAPTER 2 The following sections provide methods for troubleshooting faults involving the Cisco 10000 series router Power Entry Modules (PEMs) and blower modules. This chapter contains the following major
More informationthe Centric 300 An advanced modular UPS up to 1800kVA/kW
the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has
More informationDP 300 B and DP 600 B Series Power systems for telecom applications
DP 300 B and DP 600 B Series Power systems for telecom applications System Solutions The DP 600B series provides various power system solutions. The modular shelf concept allows for flexible and expeditious
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationCisco CRS 16-Slot Chassis Power Systems
This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power
More informationPower Supply System for BTS Site
Power Supply System for BTS Site 48V300A extendable to 350A FnS Power Technology Inc. www.sacredsun.com, www.fnspower.com Page 1 of 7 48V300A(15KW) Power System Solutions and configurations 1 FS-Rectifier-48V50A
More informationDC POWER SUPPLIES DNX 110/220 V
DC POWER SUPPLIES DNX 110/220 V ISO 9001 Power supply systems DNX are dedicated to supply the equipment which needs for its operation direct voltage 110 / 220, with emphasis on maximum reliability and
More information1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA
The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance
More informationEaton DC Power Solutions
Eaton DC Power Solutions 19 sub-rack Modular 3U and 6U options Up to 6 rectifier modules Pre-configured software High power density (24/48V: 300/250A, 6U, 19 ) Multiple AC option (1Ø, 3Ø, 2Ø) Fast on-line
More informationPOWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)
POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General
More informationISMG Solar Inverter. General Description. Type Selection. Ordering Key ISMG 1 50 EN. Approvals RD 1663/2000 RD 661/2007 DK5940 VDE
ISMG 1 60 General Description High PV input voltage range (suitable for voltage between 100 VDC to 450VDC) and efficient MPP Tracking Up to 2 / 3 independent MPP Tracking controlled by an exclusive Smart
More informationRT4F-120V/20A-WAC RECTIFIER
The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with
More informationProduct Specifications
Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin
More informationHVDC Innovation, XECHNO Power & Fresh HVDC
1 HVDC Innovation, XECHNO Power & Fresh HVDC Energy Saving Technology for the Data Center Green Consulting Business Unit Solution Business Division NTT DATA INTELLILINK Corp. Problems facing data centers:
More informationRT4B-110V/12A RECTIFIER
The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationINSTALLATION MANUAL SLI 50 INVERTER
INSTALLATION MANUAL SLI 50 INVERTER www.unipowerco.com Manual No. SLI-50-48-3 2016 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationMicro Instruments price list All pricing excludes 15%
Micro Instruments price list All pricing excludes VAT @ 15% - 2019 Product Description Solar Smart R1 Solar MPPT regulator 12/24V - 20Amp with R2 799.00 5 Way Relay board R360.00 Ethernet + SNMP support
More informationTotal Reach ISDN/DDS Isolation Card P P30059 Isolation Card
Total Reach ISDN/DDS Isolation Card P30101 120VAC/130VDC to 24VDC External Power Supply Without Backup Battery P30059 Isolation Card Description & Installation Printed in USA 09/11 T0346 Rev. C Table of
More informationInfinisolar V Hybrid-On Grid Inverter with Energy Storage
Infinisolar V Hybrid-On Grid Inverter with Energy Storage Pure sine wave output Self-consumption and Feed-in to the grid Programmable supply priority for PV, Battery or Grid User-adjustable charging current
More informationString Inverter (SUN2000-8/12KTL)
String Inverter (SUN2000-8/12KTL) 2 MPPTs for versatile adaptions to different module types or quantities built up with different alignments 4 strings intelligent monitoring and 80% time saving for fault
More informationInnovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring
Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM
More informationHYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home
HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the
More informationMSR 2400R. Rugged Power System for Military and Heavy Duty Applications
MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC
More informationZXA10 C320 Product Introduction V2.0
ZXA10 C320 Product Introduction V2.0 The small-capacity OLT C320 overview ZXA10 C320 Compact Frame: 2U height, 19-inch rack installation Unified Platform: GPON/P2P/XG-PON1 User-side Interfaces: 8/16*xPON
More informationTechnical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva
GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91
More informationAlternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.
Alternative Energy Series and Field of Use LVD Series Low-Voltage Disconnect (LVD) stops battery damage due to over discharge by disconnecting the battery at an adjustable voltage. DCDC Series Regulated
More informationFEATURES AND BENEFITS. Installation and operation. Controller
DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.
More informationGoodrive100-PV Solar Pumping Inverter
Goodrive0-PV Solar Pumping Inverter Your Trusted Industry Automation Solution Provider Service line:8-7-8389 E-mail:overseas@invt.com.cn New Energy Vehicle Electric Control System Y/1-0 V1.0 Product introduction...3
More informationHuawei Embedded Power System
Huawei Embedded Power System HUAWEI TECHNOLOGIES CO., LTD. Contents Embedded DC Power System ETP483-A1... 1 ETP489-A2... 2 ETP4815-A3... 3 ETP482-C5A1... 4 Rectifier Module R4815G1... 5 R4815N1... 6 R483G1...
More informationRAILWAY & METRO MEETING ALL POWER REQUIREMENTS ALONG THE TRACK
RAILWAY & METRO MEETING ALL POWER REQUIREMENTS ALONG THE TRACK do you have the power to take your raıl servıce ınto the future? Safety, timeliness and efficiency are the hallmarks of high quality train
More informationPower Meter PowerMonitor 500
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific
More information1. Chapter 1 24/48/110/220VDC Power Supply System
1. Chapter 1 24/48/110/220VDC Power Supply System A. Outline of 24/48/110/220VDC Power Supply System Picture Picture 2*Rectifier module 3*Rectifier module 6*Rectifier module 10*Rectifier module Rectifier
More informationDC Power Solutions Overview. DC Power Solutions for EVERY Network Application.
DC Power Solutions Overview DC Power Solutions for EVERY Network Application. DC Power Solutions for Every Network Application Eaton recognizes the challenges that are unique to different customers applications.
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationTECHNICAL DESCRIPTION
MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up
More information550 and 750 VA a multi-socket UPS to make all your connections easier. Protection adapted to meet all your needs
NeTYS PL 550 and 750 VA a multi-socket to make all your connections easier An innovative solution A compact design, it integrates a larger number of sockets adapted to IT environments, facilitating connection.
More informationCSPS-6K (Shelf Type) POWER you need POWER SHELF
CSPS-6K (Shelf Type) REV: 081418 SHELF PRODUCT FEATURES: Hot pluggable n+1 Redundancy Controlled, measured and reported by TCP/IP Modular design for accommodating high power applications 19 Inch Rack Mount
More informationEP Series II UPS 230 V
EP Series II UPS 230 V 1000/2000/3000 VA Uninterruptible Power Supply (UPS) geindustrial.com Non-stop pure power Today s 24/7 business world depends on 24/7 power availability and demands zero down time.
More informationFCU (FREE COOLING UNIT)
FCU (FREE COOLING UNIT) FCU reduces the AC running hours on the telecom site Controller Features: Can control upto two AC and one free cooling unit Temperature control Humidity sensor Structural Features:
More informationMUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA
MUST 900 3 Phase Modular UPS Hot swappable, scalable 30kVA to 900kVA Finally the benefits of Modular ups are for all MUST 900 The MUST 900 series is an uninteruptible power supply, three phase input/output,
More informationSBS-S SERIES DC LOAD BANK USER MANUAL
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com SBS-S SERIES DC LOAD BANK USER MANUAL Models Covered SBS-4830S SBS-1110S SBS-2206S
More informationGRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2
USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL
More informationPA ROUTERS. The following criteria can be applied when choosing the network transition:
PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied
More informationPCU Supervisory module for the RM 1000 series
Supervisory module for the RM 1000 series PCU 10.00 Microprocessor based control unit for supervision of internal and external functions in systems comprising RM 1000 rectifiers. Input power: 18-72V DC
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationDC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications
DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications DC POWER OVERVIEW BROCHURE NETSURE APPLICATIONS yradio Base Station / Microwave Site ywireless & Wireline Access
More informationSmart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted
ACU2000 Series ACU2000 ( Array Controller Unit) is a powerful integration of PV array communication and other smart functions. built-in Anti-PID module built-in (optional) Multiple communication interfaces
More informationSDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)
SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension
More informationInverter W and 12500W
Inverter SIRIO EVO 10000W and 12500W w w w. a r o s - s o l a r. c o m w w w. a r o s - s o l a r. c o m SIRIO EVO CLASS B DIFFERENTIAL Each device has an internal type B differential protection in compliance
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationHardened PoE Ethernet Switch
Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationCompact Redundancy Switch 2:1 RSCC-2
Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is compact solution for a 2:1 Redundancy System. It can be used for upconverters, downconverters, modulators and modulator-upconverters.
More informationRT12-240V/2.4kW Rectifier Specification
The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between
More informationAIAS. Technical description
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -
More informationCisco TelePresence MSE 8000
Data Sheet Cisco TelePresence MSE 8000 Figure 1. Cisco TelePresence MSE 8000 Product Overview The Cisco TelePresence MSE 8000 (MSE 8000) is a high-capacity voice and video conferencing media services engine.
More informationALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION
ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA
More informationIKS-G6524A/G6824A Series Quick Installation Guide
IKS-G6524A/G6824A Series Quick Installation Guide Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationIntelligent DC UPS Module
Intelligent DC UPS Module 2V/9~36V DC Input, 2V DC Output Uninterruptible Power Supply Module with Diagnostics Features Model Name AUPS-A0 / AUPS-A20 Input Power AUPS-B0 (2V) AUPS-A20 (9~36V) AUPS-B20
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation
More informationCompact Redundancy Switch 2:1 RSCC-2
Compact Redundancy Switch 2:1 RSCC-2 The WORK Microwave Redundancy Switch RSCC-2 is a compact solution for a 2:1 redundancy system. It can be used for upconverters, downconverters and with special firmware
More informationRedundant Power Supplies. Keep Machines Up When Power Goes Down
Redundant Power Supplies Keep Machines Up When Power Goes Down When your operation is critical, you need power you can count on. Redundant Power Systems are ideal for any equipment where the highest attainable
More informationCVH Slot Media Converter Chassis Quick Installation Guide
CVH-2000 14-Slot Media Converter Chassis Quick Installation Guide Ver. 1.2-1305 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 1 2. HARDWARE DESCRIPTION... 2 REAL PANEL...
More informationSmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1500XLRT2U Highlights 1.5kVA / 1500VA / 1350W line interactive 2U
More informationTechnical Data SINVERT PVS2000
Technical Data SINVERT PVS2000 The solar inverter is used in PV systems to convert the direct current from the PV generators into a three-phase current. This three-phase current is then fed into the connected
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationFlatpackS Modules. User's Guide. Rectifiers and Supervision. FlatpackS DC Power Supply Systems. Anatel Homolgation Numbers
User's Guide FlatpackS Modules Rectifiers and Supervision FlatpackS DC Power Supply Systems Anatel Homolgation Numbers Rectifier 0863-15-2298 Power System 0864-15-2298 aparecer aqui. Erro! Use a guia Página
More informationDIRIS Digiware D and C Communication and control power interfaces
Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data
More informationPowerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)
Powerstar PS3204rm2u PS3204 tower (120V) 3.4 H x16.9 W x19.7 D 85 x 430 x 497mm Model upgrade from PS3200 (GXT2) and PS3203 (GXT3)- now using Liebert GXT4 electronics Double Conversion true online type
More informationDACS ELECTROSYSTEMS PVT.LTD
DACS ELECTROSYSTEMS PVT.LTD Introduction of DACS DACS Electrosystems Pvt.Ltd is located in Pune (Mah), India Ever since it was established in 1981 it commenced with design, manufacturing and supply of
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationGTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W
GTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W GTI Series Inverters For Grid User Manual System Function Directly connected to the solar panels (do not need to connect the battery) Using precise MPPT function,
More informationCHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)
E1 over Ethernet Multiplexer (TDM over IP) Tranmission of up to 4x E1 PDH, G.703/704/723 E1 2048Mbit/s channels over Ethernet/IP network Built-in 5 port Gigabit Ethernet switch (4x 10/100/1000 Mbit/s RJ45
More informationSmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS
SmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS Model #: SMX5000XLRT3U 5000VA 230V Sine Wave Expandable Rack/Tower UPS; all-in-one chassis requires 3 rack spaces total Battery-independent
More informationTME Modular Series UPS System kva/kw - 208/220 VAC
GE TME Modular Series UPS System 15-90 kva/kw - 208/220 VAC TME Modular Series UPS 15-90 kva/kw Highest Technology with Modular Design GE s TME Series UPS is one of the most reliable three-phase UL UPS
More informationaerl PRODUCT DATASHEET MAXIMIZER TM RANGE PRODUCT OVERVIEW COOLMAX SR - Wall Mount Australian Energy Research Labs AER G2 v5 1 February 2016
PRODUCT OVERVIEW The AERL COOLMAX SR is a high efficiency, buck only, common positive Maximum Power Point Tracker (MPPT). It is the latest development in the AERL MAXIMIZER TM Range, which was pioneered
More informationclarity 3 Programmable Controller
clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated
More informationSwitched Mode Power Supply Operating manual PAP800
Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced
More information