SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

Size: px
Start display at page:

Download "SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide"

Transcription

1 SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope Quick Start Guide 99 Washington Street Melrose, MA Phone Toll Free Visit us at Quick start guide will explain basic information about the unit. For complete Operation and Safety Information, Please refer to the 1 SBS-600/700 Quick Start Guide Revision 1.0-5/2014

2 User Manual supplied on the CD-Rom included with the Quick start guide. READ THE USERS MANUAL PRIOR TO OPERATION "Pay special attention to the SAFETY Information sections of the Quick start guide and the user s manual Attention Attention mark is displayed to draw ATTENTION during use. Meter could be damaged or important Data may be lost if the unit is used improperly. Warning Warning mark is displayed to indicate improper use. Operating outside of equipment ratings could cause serious personal injury or fatal death. [Safety Symbol] Table lists and describes the safety symbols shown on Meter or in User Manual. : DC (Direct Current or Voltage) : AC (Alternating Current or Voltage) : DC and AC : Earth Ground : Double Insulation : Power Supply OFF : Power Supply ON : Warning of Electric Shock : : Warning of Danger : CategoryⅡ 1000V Overload Protection(Multi-meter Function :Model SBS-600 SBS-700 ) : CategoryⅢ 600V Overload Protection(Multi-meter Function Model SBS-600, SBS-700) : CategoryⅢ 300V Overload Protection(Scope Function, Model. SBS-700) [Notes for Safe Operation] WARNING: USE EXTREME CAUTION IN THE USE OF METER The improper use of meter may result in injury or death. Follow all safeguards in this manual, in addition to the normal safety precautions used in working with live electrical circuits. DO NOT ATTEMPT TO SERVICE the meter if you are not qualified to do so. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com 2

3 [WARNING ] Pay attention when testing conditions exceed 60V DC, 30V AC rms or 42.4V AC Peak that can cause an electric shock. Do not connect the Ground wire to voltage higher than 0V DC, 30V AC rms or 42.4V AC Peak. Use only the proper accessories supplied with the meter. Rechargeable Battery Pack, AC Power Adapter and Internal Charger, Test Lead, Probe, Logic/Signal Cable set. Warranty will not cover Meter Measurement failure or damage from improper accessories other than supplied by manufacturer of the Meter. Connect and disconnect properly. Connect Test Leads, Probes or Cables to the Meter before connecting to the active circuit to be tested. Disconnect Leads, Probes or Cables from the test circuit prior to disconnecting them from the meter. Testing Probe always connected with Testing Circuit in series. Replace the Ni-MH Battery Pack only with an equivalent from the Manufacturer. Remove AC Power Adapter, Test Lead, Probe and Cable from Meter when replace the Battery. When the Battery Warning Symbol is blinking on the display, the measurement may display in error. Recharge the battery or replace. Observe all terminal ratings. Observe all rating and marking oin the Meter. Refer to Operator manual for detailed information. [ Max Input Voltages] - Scope Input: 300V CATⅢ. - Meter Input: 600V CATⅢ. Do not apply any voltages when measuring OHM (resistance) or Capacitance for the Meter Mode. Do not use Meter where in or near explosive, flammable, wet or damp environments. Do not use Meter with the Case Cover open for any reason. Fuses should only be replaced with the proper size and rating as specified in the manual. Do not expose circuit. [ATTENTION] Before testing in Resistance, Capacitance, Continuity or Diode modes, disconnect any power supply to the circuit being tested and discharge High Voltage Rated Capacitance. Do not attempt Voltage measurement while measuring Current. [ENVIRONMENT] The Meter is designed Indoor use in following environment conditions Operating Temperature: 32 F F (0 C ~ 50 C) Guaranteed Accuracy Temperature: 73.4 F +/- 41 F (23 0 C +/- 5 C) Operating Humidity: 80% R.H. or less Storage Temperature: 32 F F (0 C ~ 70 C) Altitude : 2000m CAT III 600V Pollution Degree : 2 3

4 WEEE (Waste Electrical and Electronic Equipment) (2002/96/EC) Meter complies with WEEE (2002/96/EC) requirements. Do not dispose Electric / Electronics device with other trash. Front View Key Pad The Keys are different by models. [Main Functional Keys] 4

5 SBS SBS Function and Menu selections automatically take effect 2 seconds after pressing the key. If the user Prefers immediate setting Pressing the ENTER key will immediately select the Function or Menu. Voltage measurement keys : AC+DC, DC, AC Current measurement keys : AC+DC, DC, AC Resistance, Continuity, Diode Check key Capacitance measurement key Auxiliary measurements (Temperature, Relative Humidity, Hi-Currents. Pressure) with use of optional accessories not included. Square wave signal out put Oscilloscope Protocol Analyzer Pattern Generator Logic Analyzer 5

6 [Secondary Function Key] [ Secondary Function Keys ] Function key Function Description Selects Sub Menu functions and modes after (main) Menu selection. Upper Line: (Short Key) One Touch press Enter Menu (Main Menu) functions and modes. Lower Line: (Long key) Press longer than 2 seconds to enter USER. To return to Menu, press Exit key Upper Line : Meter setup Auto Ranging mode Lower Line : (Long key) Press longer than 2 seconds to enter Manual measurement mode (Range) - In Manual Range, range up/down can be selected with a Short key press (One touch) - To return to Auto measurement mode, hold key down (longer than 2 seconds) Upper Line: (Short Key) One Touch press enter Data Logger mode. Lower Line: (Long key) Hold longer than 2 seconds to enter Save (Data) and Recall (Data) mode. Save or Recall selection change available at sub-mode. - Press Short Key to change Logger Mode. - Press F4 Exit to leave Logger mode. Upper Line (Manual Hold): (Short Key) One touch press to enter Hold/Run mode. Hold the present measurement value in Display and can save the value. Change Hold or Run can be done (Short Key) One Touch press. Lower Line (Automatic Hold) : (Long key) Hold longer than 2 seconds to enter Auto Hold mode. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com 6

7 I (Help): (Short Key) One Touch press to enter Help mode. Brief Information on present function is displayed. Back Light On/Off: Hold longer than 2 seconds to enter Back Light display mode. Help: short key(50ms), Backlight: long key(2s) Turn the meter power ON / OFF Hold Longer than 2 seconds to power ON / OFF Cursor buttons select an item in Menu. Adjust Display Ratio. Scroll the information and Input Data LCD Display Scope Screen No Symbol Description 1 RUN Present measurement is proceeding and working. 2 HOLD Measurement is being held momentarily 3 V/div Volt (Vertical Axis) Division indicator 4 T/div Time (Horizontal Axis) Division indicator 5 Trigger Trigger indicator for Level, Position or Edge direction 6 Coupling Input Coupling selection (DC/AC) 7 Peak Peak Detection selection (ON/OFF) 8 V/Position Volt (Vertical Axis) Position adjustment 9 T/Position Time (Horizontal Axis) Position adjustment 10 Trig Level Trigger Level adjustment 7

8 DMM Screen No symbol Description 1 Minimum. Maximum, Average measurement 2 Can select Measuring Range in Automatic method or Manual method 3 Freeze the present reading in display. 4 Freeze the present reading in display. 5 Sub Menu The Subsidiary Menu. After main menu selected, sub menu tree show up to select 6 Bar-Graph Input Signal is displayed in Bar-Graph. refer details " Bar-Graph page ) 7 Compare with a reference value and display the Difference. 8 Negative Reading 9 Input Over Voltage warning that exceeds the defined safety protection voltage 10 Remaining Battery Capacity level to use. 11 Being connected with AC Power Adapter. 12 Sampling, Run time 13 Measurement mode.(dcv, ACV, Ohm, Capacitance, Diode) 14 Audible signal is active 15 (Bar Scale) Range of Meter 16 Secondary measurement secondary measurement information of Input Signal (Hz. db m) 17 Unit symbol is displayed at right side of the measurement 8

9 Data Logger Screen No Symbol Description 1 Measuring Mode. (DCV, ACV, Ohm, Capacitance, Diode) 2 RUN and STOP of Data Logger function 3 Run Time 4 Accumulated Sample Q ty in Data Logger. 5 Maximum Display Range 6 Minimum, Maximum, Average of the Samples 7 Total Time Scale of Data Logging. 8 Present Measurement Value 9 Change the Time Scale (left - right horizontal axis) to review closely on the specific Time Zone. 10 Zoom (at Regular Ratio) the specific waveform quickly (up/ down Vertical axis). 11 Data Logger Data Logger Display 9

10 Logic Analyzer Screen Protocol Analyzer Screen [Logic Analyzer, Protocol Analyzer Display Symbol] No Symbol Description Logic Analyzer: Pattern, Duration 1 Condition Protocol Analyzer: CAN, LIN, I2C, UART, USB, I2S SMBus, SPI, DMX512, 1-Wire 2 Time/div Measurement Time/div Indicator 3 Channels Displays all the Input Channels 4 Horizontal Time Division & Position adjustment 5 Trigger Trigger Mode, Source, and Trigger Level adjustment 6 Cursor Horizontal Cursor adjustment 7 Condition Detailed condition setting for each Logic or Protocol type 8 Information Display window to show the trigger condition or channel input information of each type 10

11 Pattern Generator [Pattern Generator Display Symbol] No Symbol Description 1 Condition UART, CAN, User Defined 2 Time/div Measurement Time/div Indicator 3 Channels Displays all the Channels (TX/RX) 4 View 5 Condition Selection of Transaction/Message, Acquisition Mode, and Cursor adjustment Selection of Trigger condition, Trigger Level, and Baud rate used to decide the speed of pattern 6 Message Used for making the format, cycle, and data of each pattern 7 Output Selection of signal out or not 8 Information Display window to show the information of In/Out Transaction or all the memorized messages [BAR-GRAPH] BAR-GRAPH display Measurement Data in Analogue Meter Display type. Can update 15 times / second. Response Time of Analogue display is faster than Digital display which Bar -Graph display is very efficient to observe display like as PEAK that input change very fast. Pattern Generator, Current Generator, logic Analyzer, MIN/MAX modes do not activate BAR-GRAPH display. 11

12 Direct Voltage, Currents and Relative display BAR-GRAPH 0 center position. At Direct Voltages and Currents, BAR-GRAPH total scale displays the Maximum of the selected measurement range. Displayed Segment indicates Measurement Size which is displayed within the Maximum Scale of the selected range. When measured value exceeds the maximum scale of the selected range, is displayed at RIGHT of BAR-GRAPH. When Direct Voltage or Current, is displayed at LEFT of BAR-GRAPH at negative MAX and is displayed at RIGHT of BAR-GRAPH at positive MAX [Measurement Status display] Status icon is displayed at top of Display. - Battery status, Present Measurement Value, Buzzer (Continuity), Data Hold, Auto Hold, AC Power Adapter Connected. [Display] Display consist of Main Measurement Display, BAR-GRAPH display, Sub function display (Sub measurement or Data) [Sub Menu Key] 4 keys (F1 ~ F4) underneath of Display. Selected functions available depend on measurement function or menu. Input Terminals To prevent from Damage, Do not apply exceeding the Rate. SBS ** CAT III 300 V for Scope input SBS Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com 12

13 Input Terminal Connection 10A ma COM Measurement SCOPE, V, Ω, Hz, Sig-out( ) 13 pin socket Terminal ( SBS-700) Input Terminal 0 A ~ A currents. (10A overload, 30sec On, 10 sec OFF) 0 A ~ 500 ma Currents measurement. Negative Terminal to all measurements. Volts, Continuity, Resistance, Diode, Capacitance, Frequency measurement and AUX (auxiliary function with external adapter : Temperature, High Current, Relative Humidity, Pressure measurement) 13 pin socket Terminal (Measurement and Output) : Logic Analyzer, Pattern Generator, Protocol Analyzer, Sig- Out Rear View and Side View 13

14 Logic, Pattern, Protocol, Signal Out - 13 Pin Cable Connection Pin No Function Pin No Function 1 Ground(Black/Clip) 9 Ground(Black/Hook) 2 Signal out(red/clip) 10 N/A 3 N/A(pin cutting) 11 N/A(pin cutting) 4 Logic5(Blue/Hook) 12 Logic1(Blue/Hook) 5 Logic6(Blue/Hook) 13 Logic2(Blue/Hook) 6 Logic7(Blue/Hook) 14 Logic3(Blue/Hook) 7 Logic8(Blue/Hook) 15 Logic4(Blue/Hook) 8 Pattern Generator RX(Red/Hook) 16 Pattern Generator TX(Red/Hook) Voltage Warning User should pay attention at the Voltage Rating and Over Voltage warning. Immediately remove the Test Lead/Test Probe from the METER when VOLTAGE WARNING comes on. Scope function Input (model SBS-700), max 300V. Other Multi-meter function Input (models SBS-600, SBS-700 ), max 600V. 14

15 Meter displays VOLTAGE WARNING regardless of AUTO or MANUAL measurement. When over the Maximum Measurement limit, the WARNING sound starts. At this case, immediately remove Test Lead/Test Probe from the Meter. When measurement range set manually. If the measurement exceeds the range, the display will show OL. Power 6*AA Alkaline Battery ( SBS-600 only ) 7.2V NiMH Battery Pack or AC Power Adapter ( SBS-700 only ) Remaining Battery Capacity Level indicator Top right display indicates Remaining Battery Capacity Level, Level Remaining Battery Fully Charged. (100%) 3/4 charged (75 %) 1/2 charged (50 %) 1/4 charged (25 %) Depleted ( 0 %) Auto Power Off During operation the unit will automatically power off after 15 minutes without a button push. User can select the Auto Power Off time (min 5 minutes ~ max 2 hours or Auto Power Off mode). [NOTE] Auto Power Off mode is not active in DATA LOGGER mode (MIN MAX, PEAK mode in operation) Auto Power Off mode is not active when the Meter is powered by ADC Power Adaptor (SBS-700 only) Battery Save Mode Auto Power Off mode is not activated during Data Logger or Auto Hold mode of operation. If no key is pressed on Meter for a certain time, Meter automatically changes to Battery Save Mode. Mode Change time is equal to Auto Power Off mode time setting. All Power off including Display, except present measurement function. Exit the Battery Save Mode by - Pressing any key - change measurement range - start PC Interface communication. Meter function and Operation Mode is not changed 15

16 Back Light Display When measurement environment is dark or it is hard to see the LCD display, hold Back Light key longer than 2 seconds, Back Light operation time can be set in USER mode Measurement Range selection (Auto/Range) Selected Measurement Range is shown at the Right of the BAR-GRAPH. If press change AUTO Range mode or Manual Range mode. When press the Range mode, measurement range is set automatically. key, at MANUAL [NOTE] Key is not active in Capacitance, Diode, or Frequency measurements which are always set to automatically Auto Ranging. Manual Range mode can be converted to Auto Range mode by holding than 2sec. Auto Range mode can be converted to Manual Range mode by holding more than 2sec. key for more key for In manual mode, the Up/Down key is activated by each press each step Up/Down. MENU After main function DSO is selected, press MAIN Menu to select Channel, Trigger, Measure, Cursor After Main Menu selected, Select Sub Menu F1, F2, F3, F4 to proceed to desired measurement. General Maintenance Wet or Dusty Input Terminals can cause incorrect measurement readings. Cleaning procedure is as follows. 1Power off the Meter and separate Test Lead/Probe from Meter. 2Reverse the Meter Top Side and Bottom Side and remove the dust in the terminal by shaking the meter. 3 Clean the Exterior Cases with soft detergent or wet cloth. Do not use Solvent or an abrasive. 4 Clean cotton swab wet with Alcohol may be used to clean out the surface of Input Terminals. To ensure proper measurements, make sure to use the correct input terminals for that type of measurement.. Do not test voltages above the ratings of the meter inputs.. Battery Replacement Do not short or reverse the polarity to discharge Battery. Do not attempt to recharge, non-rechargeable batteries. 16

17 [Note] Model SBS-600 uses only 6 * AA, 1.5V Alkaline battery - Non Rechargeable Battery. Model SBS-700 uses only the supplied 7.2V NiMH Rechargeable Battery Pack. When Battery low signal is blinking, In the model SBS-600, replace with New AA Alkaline battery cell as soon as possible. In the model SBS-700, recharge the battery pack as soon as possible. If Battery is completely depleted, and needs to be replace with a new battery, please replace battery using the following procedure. 1Remove the Holster Case from the Meter. 2Remove Battery Cover from the Rear Case of the meter. 3Replace Battery and be sure to connect correct polarity inside the battery compartment. 4Close Battery Cover and assembly in reverse order of above when opening Battery Compartment Battery Charge (model SBS-700 only). Do not discharge battery with reverse polarity. Do not use any other Rechargeable Battery. Use only the 7.2 V NiMH battery pack supplied from original manufacturer. Connect the Battery with the proper polarity. When charging the battery, use only the AC Adapter and Internal charger supplied from the original manufacturer. Please follow Battery Charging procedure. 1 Connect the DC Power adapter to Power Outlet. 2 Plug charging connector into the SBS When Charging is completed, FULLY CHARGED message is displayed on the screen. 4 If Battery is fully charged, disconnect DC Power Adapter. 5 Do not charge Battery while meter is being use Fuse Replacement If the Fuses open due to fault, Replace fuses using the procedure below ; 1Power off the Meter. Disconnect Test Lead from Meter. 2If DC power adapter is connected, disconnect the adapter from the meter. 3Separate Battery Cover from meter. 4Pull out one end of defect Fuse from Fuse Clip. 5Replace with same size and rating Fuse. Fuse should be placed in center of Fuse Clip. 6Do not touch any other component besides Fuse. 7Assemble the Battery Cover to the meter 8Fuse Ratings and Dimensions are as below ; [Fuse Rating and Dimensions] 500mA/250V 1OA/250V 5mm 20mm (FF) 6.3mm 32mm (FF) 17 Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

SBS 600. User Manual. Graphical Digital Multi-meter. SBS-600 Users Manual Revision 1.0-5/2014

SBS 600. User Manual. Graphical Digital Multi-meter. SBS-600 Users Manual Revision 1.0-5/2014 SBS 600 Graphical Digital Multi-meter User Manual 1 Read the Users Manual prior to using the Meter Pay special attention to the Safety Precautions section of the manual. Attention Attention mark may be

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

User Guide True RMS Multimeter Extech EX205T

User Guide True RMS Multimeter Extech EX205T User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging

More information

ETHOS Auto Ranging Digital Multimeter

ETHOS Auto Ranging Digital Multimeter ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions

More information

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT

More information

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented User's Guide Digital Multimeter plus IR Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Extech 450 Patented Introduction

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

2 in 1 LAN Tester and Multimeter Model:

2 in 1 LAN Tester and Multimeter Model: 2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured

More information

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery

More information

USER MANUAL. True RMS Multimeter. Extech EX430A

USER MANUAL. True RMS Multimeter. Extech EX430A USER MANUAL True RMS Multimeter Extech EX430A Introduction Congratulations on your purchase of the Extech EX430A True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter User's Guide 800 Amp Clamp Meters EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter Introduction Congratulations on your purchase of the EX710, EX720, or EX730 Clamp DMM.

More information

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. TRMS Digital Multimeter. Instruction Manual INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument

More information

Autoranging Mini Multimeter

Autoranging Mini Multimeter User Manual Autoranging Mini Multimeter Model MN16A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter.

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...

More information

EARTH RESISTANCE & RESISTIVITY TESTER

EARTH RESISTANCE & RESISTIVITY TESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-ET103 EARTH RESISTANCE & RESISTIVITY TESTER INSTRUCTION MANUAL INDEX 1. INTRODUCTION...

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www. Model R5010 TRMS Digital Multimeter Instruction Manual reedinstruments www com Table of Contents Safety...3-4 Features... 5 Specifications...5-8 Instrument Description...8-9 Operating Instructions...10-16

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314 Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 Introduction Congratulations on your purchase of the Extech EX310 MultiMeter. The EX310 offers AC/DC Voltage, AC/DC Current,

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) User Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

Digital Multimeter User's Manual

Digital Multimeter User's Manual Digital Multimeter User's Manual MS8238C MS8238C DIGITAL MULTIMETER FUNC HOLD RAN NCV TEMP V μa ma 12V 9V 1.5V CAT III COM FUSED 10A 30 sec. every 15 min. 200mA FUSED Autorange Auto power off TEMP maμav

More information

DC / AC True RMS Watt Clamp DMM

DC / AC True RMS Watt Clamp DMM 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 380940 Product Page DC / AC True RMS Watt Clamp DMM 10W or 100mA

More information

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A USER MANUAL True RMS Multimeter plus IR Thermometer Extech EX470A Introduction Congratulations on your purchase of the Extech EX470A True RMS Autoranging Multimeter plus IR Thermometer. This meter measures

More information

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter Model MN15. User's Guide Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

True RMS Multimeter with IR Thermometer

True RMS Multimeter with IR Thermometer Owner's Manual True RMS Multimeter with IR Thermometer Model No. 82024 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Autoranging Multimeter plus IR Thermometer Extech 450 Patented User's Guide Autoranging Multimeter plus IR Thermometer Extech 450 Patented Introduction Congratulations on your purchase of the Extech 450 (part number EX450) Autoranging Multimeter plus IR Thermometer.

More information

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1 www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented User's Guide True RMS Multimeter plus IR Thermometer Extech 470 Patented Introduction Congratulations on your purchase of the Extech 470 (part number EX470) True RMS Autoranging Multimeter plus IR Thermometer.

More information

7032 Digital-Analog Multimeter

7032 Digital-Analog Multimeter 7032 Digital-Analog Multimeter OPERATOR S MANUAL CONTENTS: 1. Safety precautions and procedures 1 1.1. Preliminary 1 1.2. During Use 2 1.3. After Use.. 2 2. General Description. 3 3. Preparation for Use..

More information

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying

More information

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

OPERATING INSTRUCTION. Pen-Type Digital Multimeter OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Industrial Multimeter Extech EX510

Industrial Multimeter Extech EX510 User's Guide Industrial Multimeter Extech EX510 Introduction Congratulations on your purchase of the Extech EX510 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Frequency

More information

USER'S MANUAL DCL-650

USER'S MANUAL DCL-650 USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,

More information

Digital Clamp Meter User Manual

Digital Clamp Meter User Manual Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...

More information

RS Stock No Instruction Manual RS Input Data Logging Thermometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2

More information

DC 100 A Current Probe

DC 100 A Current Probe 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Model: CP62 Visit us at www.testequipmentdepot.com DC 100 A Current Probe USER MANUAL 1 Safety Summary The following safety

More information

True RMS Industrial Multimeter Extech EX530

True RMS Industrial Multimeter Extech EX530 User's Guide True RMS Industrial Multimeter Extech EX530 Introduction Congratulations on your purchase of the Extech EX530 True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current,

More information

True RMS Industrial Multimeter Extech EX520

True RMS Industrial Multimeter Extech EX520 User's Guide True RMS Industrial Multimeter Extech EX520 Introduction Congratulations on your purchase of the Extech EX520 True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current,

More information

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28 SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS...... 1 1. SAFETY INFORMATION...... 2 WARNINGS...... 2 SAFETY INFORMATION..... 3 BATTERY PRECAUTIONS...... 5 2. INTRODUCTION...... 7 FEATURES......

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...

More information

Autoranging Multimeter Extech EX503

Autoranging Multimeter Extech EX503 User's Guide Autoranging Multimeter Extech EX503 Introduction Congratulations on your purchase of the Extech EX503 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

General Warranty. For more details, please refer to the user manual, it can be downloaded at

General Warranty. For more details, please refer to the user manual, it can be downloaded at General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 1 year from the date of purchase of the product by the original purchaser from the

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-773 61-775 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending User's Guide True RMS Multimeter plus IR Thermometer Extech 470 Patent Pending Introduction Congratulations on your purchase of the Extech 470 (part number EX470) True RMS Autoranging Multimeter plus IR

More information

General Warranty. For more details, please refer to the user manual, it can be downloaded at

General Warranty. For more details, please refer to the user manual, it can be downloaded at General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 1 year from the date of purchase of the product by the original purchaser from the

More information

True RMS Digital Bench Multimeter Model:

True RMS Digital Bench Multimeter Model: True RMS Digital Bench Multimeter Model: 72-1016 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1,

More information

User s Manual. Mini MultiScope II MODEL

User s Manual. Mini MultiScope II MODEL User s Manual Mini MultiScope II MODEL 381265 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants the basic instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

AC/DC TRUE RMS CLAMP METER ACM-2036

AC/DC TRUE RMS CLAMP METER ACM-2036 AC/DC TRUE RMS CLAMP METER ACM-2036 User s Manual Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Autoranging Mini Multimeter Model MN16A

Autoranging Mini Multimeter Model MN16A User's Guide Autoranging Mini Multimeter Model MN16A Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model User's Manual Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface Model 380366 Introduction Congratulations on your purchase of the Extech 380366 Datalogging Insulation Tester. The

More information

Wireless TRMS Multimeter

Wireless TRMS Multimeter User Manual Wireless TRMS Multimeter Model EX540 Additional User Manual Translations available at www.extech.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance,

More information

Wireless TRMS Multimeter and Insulation Tester

Wireless TRMS Multimeter and Insulation Tester User's Guide Wireless TRMS Multimeter and Insulation Tester Model MG302 Introduction Congratulations on your purchase of the MG300 True RMS MultiMeter Insulation Resistance Tester. This meter measures

More information

True RMS Multimeter with IR Thermometer

True RMS Multimeter with IR Thermometer User Guide True RMS Multimeter with IR Thermometer Extech EX210T Introduction Thank you for selecting the Extech EX210T True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current,

More information

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC-1010.2-031 CAT I or CAT II, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual:

More information

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable

More information

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer User's Guide Introduction Congratulations on your purchase of the Extech EX820 True RMS 1000A Clamp Meter. This meter measures AC/DC Voltage,

More information

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual 255 Digital Clamp-on Meter Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5 C. TECHNICAL

More information

WARNING CAUTION 1. SAFETY

WARNING CAUTION 1. SAFETY Instructions for: Professional auto ranging Digital Multimeter - 8 Function MOdel No: TM102 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according

More information

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EX820

More information

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual 265 Digital Clamp-on Meter Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5 C. TECHNICAL

More information

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40 OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40 Version 1.5 TABLE OF CONTENTS 1 INTRODUCTION... 4 2 SAFETY... 5 2 2.1 INTERNATIONAL SAFETY SYMBOLS... 7 3 PREPARATION OF THE METER FOR OPERATION... 7 4 FUNCTIONAL

More information

True RMS Multimeter with IR Thermometer

True RMS Multimeter with IR Thermometer User Manual True RMS Multimeter with IR Thermometer Model EX570 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EX570 True RMS

More information

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

ENGLISH. User manual.

ENGLISH. User manual. ENGLISH User manual Copyright HT ITALIA 2012 Release EN 2.00-18/12/2012 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use... 3 1.3. After use...

More information

Earth Resistance and Resistivity Tester

Earth Resistance and Resistivity Tester User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model GRT350

More information

Power Prowler USER MANUAL PLR In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables.

Power Prowler USER MANUAL PLR In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables. TM Power Prowler USER MANUAL 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables PLR600 Revison 08/19/13 www.t3innovation.com TM Power Prowler 3-In-1 DMM/TDR Cable Fault Finder for Energized

More information

Wireless TRMS Multimeter and Insulation Tester

Wireless TRMS Multimeter and Insulation Tester User Manual Wireless TRMS Multimeter and Insulation Tester Model MG300 Introduction Congratulations on your purchase of the MG300 True RMS MultiMeter Insulation Resistance Tester. This meter measures AC/DC

More information

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L OPERATOR S INSTRUCTION MANUAL MAS830 MAS830L DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC -1010 concerning electronic measuring instruments with an overvoltage

More information

Digital Clamp-on Meter Amp Plus. Instruction Manual

Digital Clamp-on Meter Amp Plus. Instruction Manual 296 Digital Clamp-on Meter Amp Plus Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5

More information

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

Keysight U1602B and U1604B Handheld Digital Oscilloscopes Keysight U1602B and U1604B Handheld Digital Oscilloscopes Quick Start Guide Safety Information Use the product only as specified by the manufacturer. Do not install substitute parts or perform any unauthorized

More information

Digital Multimeter Instruction Manual

Digital Multimeter Instruction Manual 126 Digital Multimeter Instruction Manual TABLE OF CONTENTS page A. INTRODUCTION 1. Congratulations..................3 2. Product Description..............3 3. EC Declaration of Conformity........4 B.

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

User's Guide. Handheld MultiScope. Model

User's Guide. Handheld MultiScope. Model User's Guide Handheld MultiScope Model 381285 WARNING MEASUREMENT OF VOLTAGE IN OSCILLOSCOPE MODE GREATER THAN 250VAC OR 360VDC WILL RESULT IN PERMANENT DAMAGE AND POSSIBLE INJURY Test Equipment Depot

More information

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years (1 year for accessories) from the date of purchase of the product by the

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Power Prowler. Quick Start Guide. 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables 600V CAT III. For Live Energized Cables

Power Prowler. Quick Start Guide. 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables 600V CAT III. For Live Energized Cables Power Prowler 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables Quick Start Guide 600V CAT III For Live Energized Cables PLR600 Revison 08/19/13 www.t3innovation.com Soft key functions

More information

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com Model R5005 True RMS Industrial Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 4 Features... 5 Specifications...5-6 Instrument Description...7-8 Operating Instructions...9-13

More information

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD MS2115B Dual Display Digital Clamp Meter Operation Manual REL MAX B.L ZERO MIN RANGE HOLD B CONTENTS 1. Safety Information...1 1.1 Preparation...1 1.2 Usage...2 1.3 Mark...3 1.4 Maintenance...4 2. Description...4

More information

CT-510. Multifunctional CCTV Tester. User Manual

CT-510. Multifunctional CCTV Tester. User Manual CT-510 Multifunctional CCTV Tester User Manual Please read these instructions carefully & save this manual for future use Content 1 Safety information... 1 1.1 Precaution before using the tester... 1 1.2

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications