Single-Axis Counter BDD 611

Size: px
Start display at page:

Download "Single-Axis Counter BDD 611"

Transcription

1 Single-Axis Counter BDD 611 Technical Description, User's Guide english

2 No D/E. Edition 0705; Subject to modification. Replaces edition Balluff GmbH Schurwaldstrasse Neuhausen a.d.f. Germany Phone Fax balluff@balluff.com

3 Single-Axis Counter BDD 611-R4Q N-00 BDD 611-R3Q N-00 for Incremental Measuring Systems Hardware version 03 Software version 10 1

4 1. Introduction 4 2. Safety Personnel Qualifications Proper use Safety Notes Safety Precautions 6 3. Technical Data 7 4. Commissioning Installation Connection Measuring system supply voltage Switching Output Logic Keypad and Front Panel Display Key functions Parameter and Function Levels Entering parameters, changing the device functions Parameter functions Parameter list Operation Display and function keys Key F key Shift Right key Up key Enter key Absolute -Incremental mode Erasing the EEPROM 33 2

5 6. RS232 interface Connecting to the PC Introduction Technical Data Functions Format determination Forward control Backward control Data control Send Receive Printer mode Serial commands Part Numbering List of Illustrations 41 3

6 1. Introduction The Balluff Single-Axis Counter is a convenient device for visualizing actual values on a machine. The device has 2 wear-free, short circuit protected driver outputs, PNP sourcing (only with 24V supply voltage). It is especially designed for use with the Balluff series BML-S _-QXY_-M _-Z0- with X = 5, 6 (supply voltage) Y = 1, 3 (signal level) Z = E, F, G, H, K, L, M, N, P, R. (min. edge separation) for Y = 1 encoder signal = RS422 Z = F, G, H, K, L, M, N, P, R. (min. edge separation) for Y = 3 encoder signal = HTL The optional RS232 port can be used for parameter setting as well as for direct connection to a printer having a serial port. 4

7 2. Safety This operating guide contains instructions for ensuring safe and proper installation and operation. If you have any difficulties which cannot be resolved by consulting this guide, please check with the machine manufacturer or vendor for additional information. Balluff GmbH is not liable for any personal injury or equipment damage resulting from improper commissioning, incorrect operation, misunderstandings or errors contained in this guide or on the display. Balluff GmbH reserves the right to make technical changes to the equipment or operating guide without prior notice. This means that errors in agreement between the equipment and the guide cannot be precluded. Pay particular attention to hazard notices in this operating guide. This equipment description should be carefully read in full before commissioning. Use of the operating guide presumes that the user is technically qualified. 2.1 Personnel Qualifications commissioning, installation and operation are to be performed only by qualified personnel. The personnel must have qualifications which are appropriate to their function and activity, e.g. Instruction and obligation to observe all application-related, regional and in-house regulations and requirements. Training in accordance with the standards of safety technology in the use and care of commensurate safety and work protection equipment. Courses in first aid, etc. 2.2 Proper use This position display has been developed solely for use on industrial machinery. 5

8 Any further use is considered improper. The manufacturer assumes no liability for damages resulting from such misuse. This risk is assumed solely by the user. 2.3 Safety Notes The following symbols are used for hazards and other important notes: The Hazard symbol warns of errors and hazards in commissioning and operation of the controller. This warning notice means a directly threatening hazard to the health of persons and contains special specifications and instructions as well as imperatives and prohibitions for preventing personal injury and damage to equipment. The Attention symbol means a possible hazardous situation and contains special specifications and instructions as well as imperatives and prohibitions for preventing personal injury and damage to equipment. The Note symbol indicates important and useful information and provides application tips. 2.4 Safety Precautions Since the device can be operated with 115V or 230V supply voltage depending on the model, be especially careful not to touch the unit and to secure the device in accordance with the relevant regulations. The device may not be opened and no screws removed from the housing! 6

9 3. Technical Data Fig. 1 Dimensions (illustration reduced) 7

10 Supply voltage 115V or 230 V AC ± 10 % or 24 V AC/DC Please specify when ordering Current draw Display Max. 150 ma, without connected measuring systems 1 x 6 decade LED display Digit height 14 mm Input signals 0 5 V low active V high active Measuring system Incremental measuring system A, A/, B, B/, Z, Z/ or A, B, Z Supply voltage 5V or 24V for 24V BDD supply voltage or 5V or 12V for 115V / 230V BDD supply voltage Current draw per channel: < 3mA at 5V < 20mA at 24V Max. 150 ma Max. input frequency: Signal A or B: 1 MHz (RS422,P22 = 1) Min. edge separation for 4x processing: 250ns Signal A or B: 500 KHz (HTL,P22 = 0) Min. edge separation for 4x processing: 500 ns Output signals 2 output drivers 24V, 600 ma, PNP sourcing Operating temperature 0 40 C Storage temperature C Relative humidity max. 90 % Installation orientation Enclosure rating any Front side up to IP42 Dimensions 72 x 96 x 71 mm 3 (W x H x D) Installation depth including connector 8

11 4. Commissioning Most damage to the device is a result of faulty cabling and incorrect parameter values. Therefore commissioning is to be performed only by trained and expert personnel. 4.1 Installation The device is inserted into a control panel with a cutout of approx. 93 x 71 mm² and screwed in place using the holder provided. 4.2 Connection The device is operated with 115V or 230V AC or with 24V DC or AC. With 115V or 230V AC voltage the relevant regulations for contact protection must be observed in order to prevent personal injury. Before connecting, compare the part label on the back of the device with the desired connection voltage. Electrical cables are to be routed in accordance with the respective national regulations (e.g. VDE). Route measuring, signal and power cables separately. We recommend using only shielded cable connected to GND on the device. Ensure that no ground loops are created. 9

12 J2 low high J1 24V 5V Con Con4 Con3 Con Fig. 2 Wiring diagram Connector and pinouts CON1 Supply voltage (230V AC) L N PE Terminal strip, 5-pin Pin 1 L, max. 100 ma Pin 2 Jumper to Pin 3 Pin 3 Jumper to Pin 2 Pin 4 n Pin 5 PE, protection ground 10

13 CON1 Supply voltage (115V AC) L N PE Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Terminal strip, 5-pin L n L N, max. 100 ma PE, protection ground CON1 Supply voltage (24V AC) L N PE Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Terminal strip, 5-pin L, max. 300 ma (note part label!) NC NC n PE, protection ground CON1 Supply voltage (24V DC) +24V GND Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Terminal strip, 5-pin +24V, max. 300mA (note part label!) NC NC GND GND 11

14 CON2 Measuring system input Terminal strip, 10-pin Pin 1 GND Pin 2 +24V, if jumper J1 at left is tied to 24V ( or +12V at 115V, or 230V AC supply voltage) +5V, if jumper J1 at left is tied to 5V Pin 3 Signal A Pin 4 Signal A/ (only for RS422, cf. Parameter P22) Pin 5 Signal B Pin 6 Signal B/ (only for RS422, cf. Parameter P22) Pin 7 Signal Z Pin 8 Signal Z/ (only for RS422, cf. Parameter P22) Pin 9 PE connection for shield Pin 10 PE connection for shield 12

15 CON3 In-/outputs (unused in-/outputs can be left unconnected) Outputs are available only together with 24V supply voltage version. Pin1 Supply for driver output 2 24 V DC Note part label! Pin 2 Output for driver output 2 (PNP sourcing) Pin 3 Supply for driver output 1 24 V DC Note part label! Pin 4 Pin 5 Output for driver output 1 (PNP sourcing) Switching input 4, input voltage 0 24 V Offset dimension/actual value output via RS232 Pin 6 Switching input 3, input voltage 0 24 V Freeze/Stop,/Absolute-Incremental Pin 7 Switching input 2, input voltage 0 24 V Set Pin 8 Switching input 1, input voltage 0 24 V Reset Pin 9 Pin 10 GND for switching inputs +24V for switching inputs CON4 RS232 interface (Option) Terminal strip, 3-pin Pin 1 Pin 2 Pin 3 RxD TxD GND 13

16 4.3 Measuring system supply voltage J1 24V 5V In order to set the supply voltage to the desired level, the back cover of the unit must be removed. Jumper 1 can then be used to select the desired voltage. (Observe data sheet for measuring system!) The respective voltage is printed on the circuit board. Jumper left 24V, for 24V supply of the measuring system (or 12V for supply voltage 115V or 230V AC). Jumper right 5V, for 5V supply of the measuring system. 4.4 Switching Output Logic J2 low high The switching input logic can be selected using Jumper J2. The switching states are printed on the circuit board. Jumper left low, inputs switch to GND. Jumper right high, inputs switch to +24V. 14

17 4.5 Keypad and Front Panel Fig. 3 Front panel Display The display is used for visualizing the position as well as displaying the parameter values in the parameter levels Key functions 1. The F switches from the display level to the calibration and parameter levels and back. 2. The key is used to select a decade (flashing), which then can be edited in one of the function levels by using the key. It is also used for changing the parameter numbers in function level The key is used for editing the flashing decade in one of the function levels. 4. The E key is used for confirming an edited value in the function levels. This key must always be pressed after entering a parameter or calibration value in order to save it. 15

18 4.6 Parameter and Function Levels Entering parameters, changing the device functions When changing control and calibration parameters, always take into account the effects on the overall system: The parameters may be protected against unintended changes by using a security code. This may be selected by the machine manufacturer himself. The device provides two levels, one for entering parameters and one for entering the set value (calibration function). 1. Calibration value function level 2. General parameter level The F key is sued to activate and exit function and parameter entry. Use the key to switch back and forth between the levels. To open a level use the E (Enter) key, which also serves to confirm an input value. Changes in the parameter setting can result in malfunction, stopping or failure. Changes to the parameter settings should therefore be made only by knowledgeable personnel. 16

19 Example: Changing the P 5 parameter in the Func2 level (parameter level): 1. Press the F key (display Func1) 2. Press the key (display Func2) 3. Press the E key (display P 00) 4. Press the key 5 times (display P 05) 5. Press the E key (display e.g. 1) 6. Shift the flashing decade using the key and increment the value using the key. 7. Confirm the value by pressing the E key. (display P 06) 8. Exit parameter entry by pressing the F key twice. (display shows actual value) If the parameter level is code-protected, then after Step 1 you must first enter the corresponding code and confirm by pressing E Parameter functions The parameters shown in the following are all performed according to the sample Parameter number Name [unit, minimum/maximum value) Parameter description. Parameters in which P00 is entered as the unit refer to the unit specified in parameter P00 (function level 2). Parameters which are filled with index ro can only be read. 17

20 Calibration level Func1: P00 Set value [P00/ ] Set value which when actuating the Set input or confirming with E is written to the actual value window. Parameter level Func2: P00 Travel distance for factor calculation [any desired length unit/ 1, 10000] Contains any desired travel distance. These two parameters are needed so that the display can be set to various mechanical conditions, such as drives, spindle stroke, etc. 1. Any desired travel distance in the desired unit and resolution (P00). 2. The number of increments sent by the measuring system to the display when traveling this distance (P01). Only if these specifications are entered in P00 and P01 with no rounding error will the display operate correctly over the entire range. Therefore you should always select a travel distance over which a whole-number quantity of increments is sent by the measuring system. P01 Increments / travel distance [resolution of the measuring system/ 1, ] Number of increments per travel distance entered in P00 (the factor is automatically calculated from P00 and P01). Example 1: The measuring system in use sends 100 increments to the display over a distance of 1.00 mm. You want the display value to be shown in increments of 1/100 mm. Therefore each increment arriving from the measuring system must be accounted for. You should therefore set P00 and P01 to the same value (e.g. 1, 1 or or 100, 100). 18

21 Example 2: The measuring system in use again has a resolution of 1/100 mm. But here you only want the display value to resolve to one place after the decimal point, i.e. 1/10 mm. This means that over a distance of 1 (0.1 mm) 10 increments are sent by the measuring system to the display. You should therefore set P00 to smaller than P01 by a factor of 10 (e.g. 1, 10 or or 100, 1000). Example 3: A machine with a spindle drive has the following key data: Spindle rise 5.0 mm / absolute encoder with a resolution of 20 increments per revolution. You want the display to resolve down to one decimal place, i.e. in increments of 1/10 mm. This means that over a distance of 50 (5.0 mm) 20 increments are sent by the measuring system to the display. Therefore you should set P00 to 50 and P01 to 20. For inch settings, enter P00 in inches. P02 Edge evaluation [../1.3] The device can evaluate one, two or 4 edges from the measuring system. This parameter must be set depending on the desired resolution and limit frequency of the measuring system. Input value Edge evaluation P03 Count direction reversal [../0.1] Changes the count direction of the display from up to down or the reverse. Input value Count direction 0 Count direction standard 1 Count direction inverted 19

22 P04 Decimal point [Decimal place/ 0, 5] This parameter is used to set the decimal place within the display. 0 = Turn off decimal place 1 = One decimal place, etc. Setting the decimal place has no effect on the display resolution. This is done only with parameters P00 and P01. P05 Code for calibrate level [6 decade number/ 0, ] By entering a code you can protect the device from calibration in function level 1. Then you are only able to calibrate to a new value after entering this code. P06 Code for parameter level [6 Decade number/ 0, ] By entering a code you can protect the parameter values in function level 2 from being overwritten. Entering parameter values is then only possible after entering this code. 20

23 P07 Front panel key functions [Function/ 0, 14] The front panel keys beyond the function levels. and E may be assigned special functions Input value Key function 0 Keys have no function 1 E Sets display to 0 2 Sets display to set value 3 Function 1 and 2 active 4 E activates offset dimension If this function is active, the offset dimension function is turned off through the external input! 6 Function 2 and 4 active 8 Incremental/Absolute changeover 9 Function 1 and 8 active 10 Function 2 and 8 active 11 Function 1, 2 and 4 active 12 Function 4 and 8 active 13 Function 1, 4 and 8 active 14 Function 2, 4 and 8 active 16 E Switches the display value, as well as all important parameters, to inches or back to mm 17 Function 1 and 16 active, etc. P08 Reset logic [type of reset/ 0, 1] Input value Reset function 0 Static reset As long as the reset input is active the display remains at 0 1 Dynamic reset The display is set to 0 with the edge of the reset pulse and then resumes counting. 21

24 P09 Encoder reset [type of encoder reset / 0, 2] Input value Reset function 0 Reset function turned off by index pulse from measuring system. 1 Reset function using index pulse from measuring system with rising edge. 2 Reset function using index pulse from measuring system with falling edge. P10 Set logic [type of set function/ 0, 1] Input value Set function 0 Static set As long as the set input is active, the display remains on the set value. 1 Dynamic set The display is set to the set value with the edge of the reset pulse and then resumes counting. 22

25 P11 Freeze/Stop/Incremental-Absolute [type of switch function / 0, 2] Selects the function of the Freeze, Stop, Incremental-Absolute input. Input value Freeze, Stop function 0 The display is frozen. The counter continues to count internally. 1 The counter is stopped. Arriving pulses are not processed. 2 The counter switches from absolute to incremental, or the reverse P12 Offset dimension [P00/ , 10000] Enter the offset dimension in units of length, such as xx.x mm or x.xx inches. This value is subtracted from the display value when the offset measurement contact is activated. When the input is deactivated the value is added again. 23

26 P13 Switching input logic [binary code/ 0.15 ] In machine building both normally open and normally closed devices are used as electrical switches. To be able to adapt the device quickly to any hardware, the switching behavior of the inputs must be determined using this parameter. The respective settings can be found in the tables below. 1. Inputs switch to GND Terminal 5 Terminal 6 Terminal 7 Terminal 8 P13 N.O. N.O. N.O. N.O. 0 N.C. N.O. N.O. N.O. 1 N.O. N.C. N.O. N.O. 2 N.C. N.C. N.O. N.O. 3 N.O. N.O. N.C. N.O. 4 N.C. N.O. N.C. N.O. 5 N.O. N.C. N.C. N.O. 6 N.C. N.C. N.C. N.O. 7 N.O. N.O. N.O. N.C. 8 N.C. N.O. N.O. N.C. 9 N.O. N.C. N.O. N.C. 10 N.C. N.C. N.O. N.C. 11 N.O. N.O. N.C. N.C. 12 N.C. N.O. N.C. N.C. 13 N.O. N.C. N.C. N.C. 14 N.C. N.C. N.C. N.C

27 2. Inputs switch to 24V Terminal 5 Terminal 6 Terminal 7 Terminal 8 P13 N.C. N.C. N.C. N.C. 0 N.O. N.C. N.C. N.C. 1 N.C. N.O. N.C. N.C. 2 N.O. N.O. N.C. N.C. 3 N.C. N.C. N.O. N.C. 4 N.O. N.C. N.O. N.C. 5 N.C. N.O. N.O. N.C. 6 N.O. N.O. N.O. N.C. 7 N.C. N.C. N.C. N.O. 8 N.O. N.C. N.C. N.O. 9 N.C. N.O. N.C. N.O. 10 N.O. N.O. N.C. N.O. 11 N.C. N.C. N.O. N.O. 12 N.O. N.C. N.O. N.O. 13 N.C. N.O. N.O. N.O. 14 N.O. N.O. N.O. N.O. 15 P14 Switching threshold of Outputs 1 [P00/ ] If the value stored here is exceeded by the display value, then Driver Output 1 is switched. P15 Switching threshold of Outputs 2 [P00/ ] If the value stored here is exceeded by the display value, then Driver Output 2 is switched. 25

28 P16 Output switching characteristic [static,clearing/ 0.1 ] Input value Output switching behavior 0 Static 1 Clearing If the value is set to 1, clearing, then the respective clear times can be set in parameters P17 and P18. P17 Clear time of switching output 1 [sec/ 0,2.50 ] The clear time of Output 1 can be selected within a range of 0 to 2.50 seconds. P18 Clear time of switching output 2 [sec/ 0,2.50 ] The clear time of Output 2 can be selected within a range of 0 to 2.50 seconds. P19 Actual value memory [on, off/ 0.1 ] Setting the parameter to 1 turns off the actual value memory. The position before powering down is no longer displayed after powering up. Cal appears in the display, which reminds the user to recalibrate the counter. P20 Sawblade correction [P00/ , ] Here a value can be stored which is subtracted from the display value when the Set or Reset function is activated in incremental mode. 26

29 P21 Switching output logic [Logic/ 0.3 ] The switching outputs can be programmed so that they switch whenever the set upper or lower limits are exceeded. Input value Output function 0 1 switches when overshot 2 switches when overshot 1 1 switches when undershot 2 switches when overshot 2 1 switches when overshot 2 switches when undershot 3 1 switches when undershot 2 switches when undershot P22 Measuring system selection [standard, with inverted / 0.1 ] The device can operate with measuring systems whose supply voltage and signal level is 5V or 10-30V. The measuring system supply voltage can be set using jumpers on the rear side. When using 5V systems, always make sure that tracks A, B Z and their inversions are connected in order to prevent problems. Setting Measuring system 0 Only tracks A, B and Z are evaluated. 1 Tracks A, A/, B, B/ and Z, Z/ are processed. 27

30 P60 Serial adress [adress/ 11,99 ] When using the serial RS232 interface option enter the unit number here. Do not use adresses like 20, 30, 40,.., 90. These adresses are reserved for unit groups. A unit will not send any answer when communication with such a adress. P61 Baudrate [baud/ 1,4 ] The following baud rates are available. Setting Baudrate/ Baud

31 P62 RS232 Mode [mode/ 0,3 ] There are different modes for serial communication available. 0 Standard RS232 protocoll according to DIN For printer usage. The display value will be send periodically to a printer in a time intervall set in parameter P63. 2 For printer usage. The display value will be send to a printer when pushing the E key. 3 For printer usage. The display value will be send to a printer when activating Con/ Pin5. P63 Time intervall to transmit actual value [seconds/ 0.00, ] When parameter P62 is set to 1 the display value will be send periodically after reaching this time. P99 Actual value for RS232 transmission [P00/ ,999999] When parameter P62 is set to 0 the display value can be read out of the unit by adressing P99. 29

32 4.6.3 Parameter list For service purposes it is advisable to document the stored parameters stored in the controller when the machine was shipped. You can use the following table for this. Parameter Specific machine setting Function Level P00 set value (calibration value) Function Level P00 Distance for factor calculation P01 Pulses/distance P02 Edge evaluation P03 Count direction reversal P04 Decimal point P05 Code for calibration level P06 Code for parameter level P07 Key function P08 Reset logic P09 Encoder reset P10 Set logic Freeze/Stop,/Absolute-Incremental P12 Offset dimension P13 Switching output logic P14 Switching threshold Output 1 P15 Switching threshold Output 2 P16 Switching characteristic of the outputs P17 Clear time Output 1 P18 Clear time Output 2 P19 Actual value memory P20 Sawblade correction P21 Switching output logic P22 Selecting the measuringsystem 30

33 P60 Serial adress P61 Baud rate P62 RS232 mode P63 Time intervall to transmit actual value P99 Actual value for RS232 transmission 31

34 5. Operation 5.1 Display and function keys Function Shift Right Up Return Fig. 4 Function keys, displays 5.2 Key F key Switches from display mode to the function levels and back Shift Right key Increments the parameter number, or shifts the flashing decade to be edited Up key Increments the number inside the flashing decade by Enter key Confirms the entry and switches to the next parameter number. 32

35 5.2.5 Absolute -Incremental mode To distinguish between absolute and incremental mode, a small "r" appears in the display to indicate incremental (relative) mode. Therefore in incremental mode there are only 5 decades in the positive and 4 decades in the negative range available Erasing the EEPROM Should it happen that a unit can no longer be initialized after powering up, there could be non-permitted values in the EEPROM memory. This memory can be deleted and the parameters set to their initialization values. To do this, turn on the device while holding down the Function, Up and Enter keys. 6. RS232 interface 6.1 Connecting to the PC An RS232 connection consists of at least 3 lines. RxD TxD GND Receive Data Transmit Data Ground A 9-pin Sub-D female on the PC is used. RxD and TxD must be cross-connected, since the sender of the one device is connected to the receiver of the other device. 33

36 6.2 Introduction The protocol is based on DIN 66019, ISO 1765, ANSI X3.28. These standards describe a control procedure in the data link of a transmission system. Only the host unit has the function of the bus master, and the units connected to it are slaves with individual addresses. Slaves are not permitted to send by themselves, but rather only when requested by the master. There are three call types for communication between master and slave. Send Receive Broadcast 6.3 Technical Data 7-bit ASCII 2400, 4800, 9600, 19200, baud 1 Stop bit 1 Start bit 1 Parity bit (even) 34

37 6.4 Functions Common to the control procedures below is that the transmission control characters specified in the code table per DIN are used for data transfer. The transmission characters are used for determining format, for forward control, backward control, and synchronization. EOT: Control character (Hex04) End of Transmit AD1: Unit address, high byte AD2: Unit address, low byte STX: Control character (Hex02) Start of Text C1: Parameter code, high byte C2: Parameter code, C3: Parameter code, C4: Parameter code, low byte XXX: Data ETX: Control character (Hex03) End of Text BCC: Block check character ENQ: Control character (Hex05) Enquiry NAK: Control character (Hex15) Not acknowledge ACK: Control character (Hex06) Acknowledge 6.5 Format determination The transmission character sequence is the format for data transfer. The following transmission control characters are used for indicating the format: STX: ETX: Control character Ctrl B (Hex02) Start of Text Control character Ctrl C (Hex03) End of Text These characters appear only once in the format. All data are sent in ASCII code. 35

38 6.5.1 Forward control The following transmission control characters are used by the control station or by the send station for specifying the transmission phases: EOT: Control character (Hex04) End of Transmit (end of transmission) ENQ: Control character (Hex05) Enquiry (station enquiry) Backward control Each transmission character sequence, each receive poll and each control command issued to one or more receive stations which does not end the receive state must be confirmed with a reply. The following transmission control characters are used for this: NAK: Control character (Hex15) Not acknowledge (negative reply) ACK: Control character (Hex06) Acknowledge (positive reply) 36

39 6.5.3 Data control In the data command the information for activating the parameters, set points and actual values are coded with the axes. Parameters are implemented as a dual array. All data are handled like parameters. This results in very easy handling of all the data to be managed. Parameter[Number][Axis] C1,C2 C3,C4 Each device is modular, and has the character of a slot. There is always a General Level and at least one Axis Level. The various levels are distributed as follows. Data command 20XX General Level (calibration value) Data command 21XX Axis 1 37

40 6.6 Send Send transfers data from the master to the slave. EOT AD1 AD2 STX C1 C2 C3 C4 XXXXXXXX ETX BCC The data string XXXXXXXX may consist of any number of numerical characters and can contain leading zeros as well as a sign. The Block-Check-Character BCC is the exclusive-or of all characters from "C1 to "ETX (all-inclusive) To prevent the BCC from ending up in the value range of the transmission control characters, Hex20 is added as soon as it is less than Hex20. If reception was correct, the module answers with "ACK, and in all other cases with "NAK. All parameters sent to the module are first stored in a data buffer. These parameters do not become active until the "activate data" command is sent. Example: Send the parameter value P to a device with Address 11. EOT 11 STX ETX BCC The device responds for a display value with "Ack 38

41 6.7 Receive The receive is used for requesting values from the modules. EOT AD1 AD2 STX C1 C2 C3 C4 ENQ When addressing is correct and the parameter code is correct, the station replies: STX C1 C2 C3 C4 XXXXXXX ETX BCC The data string XXXXXXXX may consist of any number of numerical characters and can contain leading zeros as well as a sign. The Block-Check-Character BCC is the exclusive-or of all characters from "C1 to "ETX (all-inclusive) To prevent the BCC from ending up in the value range of the transmission control characters, Hex20 is added as soon as it is less than Hex20. If the request string contains an invalid or unknown parameter code, the station replies: STX C1 C2 C3 C4 EOT In all other cases with "NAK Example: Request the display value from a device with Address 11. EOT 11 STX 2199 ENQ The device replies for a display value of 12 STX ETX BCC 39

42 6.8 Printer mode If a printer is connected to the device using an RS232 interface, the following data string is sent cyclically or on demand. AD1 AD2 ± XXXXXX LF CR The device sends its address, followed by the actual value, Line Feed and Carriage Return. Data can be read from the device or written to it even while printer mode is active. Note however that two transmissions in succession cannot take place, since otherwise erroneous data may be on the bus. 6.9 Serial commands 3 commands can be sent over the serial interface. 1. Activate data, data string number Save data in EEPROM, data string number Calibrate, data string number 139 Data command 2152 is used to transmit a command. Example: Send the Activate data command to a device with Address 11. EOT 11 STX ETX BCC 40

43 7. Part Numbering The following variants of the BDD 611 are available: BDD 611-R4Q N-00: Supply voltage 115 / 230V AC No digital outputs 4 digital inputs No serial port BDD 611-R3Q N-00 Supply voltage 24V DC/AC 2 digital outputs (transistor output), PNP sourcing 4 digital inputs No serial port 8. List of Illustrations Fig. 1 Dimensions (illustration reduced)... 7 Fig. 2 Wiring diagram Fig. 3 Front panel Fig. 4 Function keys, displays

44 42

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

BNI USB A501. USB IO-Link Master User's Guide. english

BNI USB A501. USB IO-Link Master User's Guide. english User's Guide english 1 2 4 Notes to the user 1.1 About this guide 1.2 Structure of the guide 1. Typographical conventions 1.4 Symbols 1.5 Abbreviations Safety 4 2.1 Intended use 4 2.2 General safety notes

More information

Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders

Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders connectable to incremental- or absolute encoders (FMAX, FEMAX, EMAX) approved standard functions (e.g. pulse scaling,

More information

BNI USB A501. User s Guide

BNI USB A501. User s Guide BNI USB-901-013-A501 User s Guide Content 1 Notes for the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross-references 2

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Manual Electronic Identification Systems BIS Processor BIS C-6_0 RS 232 C-6_ _836905_E_0704.p65 Deutsch bitte wenden!

Manual Electronic Identification Systems BIS Processor BIS C-6_0 RS 232 C-6_ _836905_E_0704.p65 Deutsch bitte wenden! 1 Manual Electronic Identification Systems BIS Processor BIS C-6_0 RS 232 Deutsch bitte wenden! 2 No. 836 905 D/E Edition 0704 Subject to modification. Replaces edition 0409. Writing convention: Control

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

11 Serial Communications

11 Serial Communications 11.1 COMMUNICATIONS PACKAGES There are a number of communication packages that can be used with the Quantum III to facilitate setup, record parameter data, view internal activity on a soft-scope and permit

More information

Compact Card Dispenser

Compact Card Dispenser SPECIFICATIONS A 1 OF 17 2008. 11. 18. Compact Card Dispenser WITH Capture Function integrated SPECIFICATIONS A 2 OF 17 2008. 11. 18. REVISION HISTORY CHECK DATE DESCRIPTION REV. PAGE 1 2008. 11. 18 First

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-206-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols

More information

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom PD1100 STAND-ALONE ALPHANUMERIC POLE DISPLAY PROGRAMMING & USER S GUIDE use the freedom Forward The information contained in this user s guide is subject to change without notice. This Programming and

More information

Installation & Operation

Installation & Operation LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

DX 345, DX 346, DX 347, DX 348

DX 345, DX 346, DX 347, DX 348 control motion interface DX 345, DX 346, DX 347, DX 348 Universal Display Units with Impulse Inputs DX 345: DX 346: DX 347: DX 348: Display only Display with Analogue Output Display with Two Presets and

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

GV204 Impulse Splitter for Incremental Encoders

GV204 Impulse Splitter for Incremental Encoders Operating Manual www.genesisautomationonline.com GV204 Impulse Splitter for Incremental Encoders Product features: Programmable encoder input A, /A, B, /B, Z, /Z, for use with RS422 or TTL differential

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Previous Configuration: BY240 Synchronous Controller Option: Parallel interface PS240 and BCD thumbwheel switch set BY106-5

More information

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042 BNI IOL102000Z012 BNI IOL104000Z012 BNI IOL104S01Z012 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302000Z012 BNI IOL302S01Z012 BNI IOL302000Z042 User s Guide Inhalt 1 Notes for the user 2 1.1. About

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 s 2 1.1. About this guide 2 1.2. Struture of the guide 2 1.3. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide BNI IOL-104-000-K006 BNI IOL-102-000-K006 IO Link Sensorhub digital User s Guide Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions

More information

DCA - 10 / DCA TTS Systems

DCA - 10 / DCA TTS Systems DCA - 10 / DCA - 20 Two Channell Load Cell Amplifie er Refere ence Manua al TTS Systems 14 Highpoint Business Village, Henwood,, Ashford, Kent,, TN24 8DH Telephone +44 (0)1233 624422 Telefax 0870 705 9678

More information

Hardware Manual RM CANview

Hardware Manual RM CANview Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling

More information

BTL6-A_10-M -A1-S115. Data Sheet. english

BTL6-A_10-M -A1-S115. Data Sheet. english BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de

More information

BIS L x-07-S4

BIS L x-07-S4 BIS L-409-045-00x-07-S4 Quick Guide 41 English www.balluff.com 1 2 3 4 5 Notes to the user 5 1.1 bout this manual 5 1.2 Structure of the manual 5 1.3 Typographical conventions 5 1.4 Symbols 5 1.5 bbreviations

More information

BIS L , BIS Z-EL-...

BIS L , BIS Z-EL-... BIS L-400-..., BIS Z-EL-... Technical Description, User's Guide English www.balluff.com 1 2 3 4 5 6 7 8 9 Notes to the user 4 1.1 About this manual 4 1.2 Structure of the manual 4 1.3 Typographical conventions

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

SERIAL INTERFACE. Series SSW-05

SERIAL INTERFACE. Series SSW-05 SERIAL INTERFACE Series SSW-05 MANUAL OF THE SERIAL COMMUNICATION SSW-05 CODE 0899.4895 E/4 MANUAL OF THE SERIAL COMUNICATION SSW-05 Series: SSW-05 Software: Version 2.1X 0899.4895 E/4 ATTENTION! It is

More information

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden!

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden! 1 Manual lectronic Identification Systems BIS Processor BIS L-60_0 RS232 Deutsch bitte wenden! 2 No. 829 572 D/ dition 0311 Subject to modification. http://www.balluff.de Balluff GmbH Schurwaldstrasse

More information

DX 342. Multi Function Counters with 2 Presets, 2 Relay Outputs and Serial RS 232 / RS 485 Interface. Operating Instructions. control motion interface

DX 342. Multi Function Counters with 2 Presets, 2 Relay Outputs and Serial RS 232 / RS 485 Interface. Operating Instructions. control motion interface control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com DX 342 Multi Function Counters with

More information

solartron digital readout model no. DR600 DR700 installation manual

solartron digital readout model no. DR600 DR700 installation manual solartron digital readout installation manual model no. DR600 DR700 1.0: Index Section Title Page 1.0 Index.....................1 2.0 Safety Summary............2 3.0 Service & Repair............4 4.0 Measurement

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL800000Z036 BNI IOL800000Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

Compact Card Dispenser

Compact Card Dispenser 9100-0140 SPECIFICATIONS A 1 OF 17 2009. 01. 19. Compact Card Dispenser WITH Capture Function integrated KYTronics Corp.,Ltd 3 rd Floor, A-Dong, Twin Town-Bldg, 703-2. Gojan-Dong, Danwon-Gu, Ansan-City,

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical

More information

KYTronics Corp.,Ltd KYT-22XX SPECIFICATIONS B 1 OF kytronics.co.kr. 3 rd Floor, A-Dong, Twin Town-Bldg,

KYTronics Corp.,Ltd KYT-22XX SPECIFICATIONS B 1 OF kytronics.co.kr. 3 rd Floor, A-Dong, Twin Town-Bldg, SPECIFICATIONS B 1 OF 18 2007. 04. 20. KYT-22XX KYTronics Corp.,Ltd 3 rd Floor, A-Dong, Twin Town-Bldg, 703-2. Gojan-Dong, AnSan-City, Kyung Ki-Do, Korea(Zip : 425-906) Tel : 82 31 485 9480 Fax : 82-31

More information

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide BNI EIP-202-000-Z016 BNI EIP-202-100-Z016 IP67 Modules, 8 Outputs BNI EIP-206-000-Z016 BNI EIP-206-100-Z016 IP67 Modules, 16 Outputs User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure

More information

BIS S-6027 Ethernet with TCP/IP-Protocol

BIS S-6027 Ethernet with TCP/IP-Protocol BIS S-6027 Ethernet with TCP/IP-Protocol Technical Description, User s Manual english www.balluff.com 1 2 3 4 5 6 7 8 9 User Notes 4 1.1 About this Manual 4 1.2 Manual layout 4 1.3 Conventions 4 1.4 Symbols

More information

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide BNI PNT-502-105-Z015 IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

SSI Indicator Multi-Function Unit with Two Relay Outputs and Serial Interface, for Use with Singleturn or Multiturn SSI Encoders

SSI Indicator Multi-Function Unit with Two Relay Outputs and Serial Interface, for Use with Singleturn or Multiturn SSI Encoders Fritz Kübler GmbH Zähl- und Sensortechnik Postfach 34 40 D-78023 Villingen-Schwenningen Tel.: 07720-3903-0 Fax: 07720-21564 www.kuebler.com SSI Indicator 0.570.010.305 Multi-Function Unit with Two Relay

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation!

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation! Digital Process Meter for SSI position sensors Please read carefully before installation and operation! Contents Contents Specifications 2 Safety instructions 3 Description 4 Mechanical mounting 4 Operation

More information

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide BNI PNT-104-105-Z015 IP67 Modules 16 Input User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

JetWeb JX6-INT1 Function Description

JetWeb JX6-INT1 Function Description JetWeb JX6-INT1 Function Description Article # 608 640 72 Edition 2.1 December 2003 / Printed in Germany Function Description December 2003 JetWeb JX6-INT1 JETTER AG reserves the right to make alterations

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

Series ID / IA / IR Dual position and differential indicators for use with two encoders or measuring systems (SSI absolute or incremental)

Series ID / IA / IR Dual position and differential indicators for use with two encoders or measuring systems (SSI absolute or incremental) Operating Manual Series ID / IA / IR 330 644 Dual position and differential indicators for use with two encoders or measuring systems (SSI absolute or incremental) Product features: Electronic position

More information

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features: Operating Manual ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz Product Features: Miniature panel housing Bright LED display with 6 digits Add-on frame for clip or screw mounting Counting

More information

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3. User Guide Modbus Module For Digistart soft starters Part Number: 477-9-3 Issue: 3 General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide BNI PBS-104-000-Z001 BNI PBS-102-000-Z001 BNI PBS-302-000-Z001 Quick start guide Content 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations

More information

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter

More information

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013 Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

CONFIGURATION: The Reader, LED Indicator, pin numbers for the 9-pin connector and the 25-pin adapter are shown in Figure 1-2.

CONFIGURATION: The Reader, LED Indicator, pin numbers for the 9-pin connector and the 25-pin adapter are shown in Figure 1-2. FEATURES: Major features of the Swipe Reader are as follows: Powered through the USB port no external power supply required Hardware Compatible with PC or any computer or terminal with an RS-232 interface

More information

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide BNI IOL106000K006 BNI IOL106S01K006 BNI IOL106S01K006C01 User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions

More information

270 MHz Control Modules

270 MHz Control Modules 2400 / 2420 / 2450 Performance Drives A D D E N D U M 270 MHz Control Modules Notices 2000.40(A2) 01 11/08 Copyright 2002-2008 by Unico, Incorporated. All rights reserved. No part of this publication may

More information

Operating instructions

Operating instructions COUNTERS CONTROLLERS ENCODERS Operating instructions Interface Description NE230 Progr. 01 Content Page 1. General information...2 2. Transmission protocol...2 3. Memory location readout...3 3.1. Examples

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations

More information

S7-300 Programmable Controller

S7-300 Programmable Controller S7-300 Programmable Controller This description belongs to the following documentation packages with the order numbers given: S7 300 Programmable Controller 6ES7 398 8AA02 8BA0 ET 200M Distributed I/O

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................

More information

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE COMMUNICATION INSTRUCTION MANUAL THT-500-A/R (C5) No. THT5CE2 2018.04 This manual contains instructions for communication functions of the THT-500-A/R. 1. System Configuration 1.1 When Using USB Communication

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

3 Input Multiplexer Operation Manual

3 Input Multiplexer Operation Manual ProMUX-3 3 Input Multiplexer Operation Manual WARRANTY Accurate Technology, Inc. warrants the ProMUX-3 against defective parts and workmanship for 1 year commencing from the date of original purchase.

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide

More information

hipecs-cio100 CANopen I/O module with 16/16 digital I/O

hipecs-cio100 CANopen I/O module with 16/16 digital I/O General The hipecs-cio100 is a low cost CANopen unit with 16 digital inputs and 16 digital outputs suitable for 24 V DC applications. The I/O s are positive switching and opto-isolated from the bus and

More information

North American Service Manual

North American Service Manual North American Service Manual MODEL PC SERIES Version 2 March 25, 1997 Revision B1.1 April 4, 2000 Prepared by TRANSCELL TECHNOLOGY, INC. TABLE OF CONTENTS Page Chapter 1: Introduction... 1-1 Chapter 2:

More information

I/O SIGNAL CONDITIONER

I/O SIGNAL CONDITIONER Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

Handbuch Identifikations-Systeme BIS Kompaktauswerteeinheit BIS M S115 M S115_841305_0611_en.p65

Handbuch Identifikations-Systeme BIS Kompaktauswerteeinheit BIS M S115 M S115_841305_0611_en.p65 1 Handbuch Identifikations-Systeme BIS Kompaktauswerteeinheit BIS M-4-007-...-S115 English please turn over! 2 No. 841 305 D/E Edition 0611 Subject modification. Replaces edition 0604. Balluff GmbH Schurwaldstrasse

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE

ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE DOC. NO. ESM-5907 REV. PAGE DATE SPECIFICATION A 1 OF 19 2002.09.18 ESM-5907 MOTORIZED INSERTION STANDARD TYPE MAGNETIC CARD READER & IC CARD READER/WRITER WITH RS-232C INTERFACE KyungDuck Bldg, 518-5,

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10 Model Number Features Very small housing Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Description This absolute rotary encoder provides

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL802102Z036 BNI IOL802102Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00 BRODERSEN Message Displays/Operator Panels Message Display Operator Panel UCT-33/36 Industrial Terminal Manual 32.00 Brodersen Controls A/S. Betonvej 0. DK-4000 Roskilde. Denmark. Tel (+45) 46 74 00 00.

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

Flex Series User Guide

Flex Series User Guide User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents

More information

Nokeval. No Manual. Model for serial inputs

Nokeval. No Manual. Model for serial inputs Nokeval No 0002 Manual Model 2800-207 for serial inputs Contents General Description... 3 Technical specifications... 3 Front panel...4 Configuration stage... 4 Resetting configuration parameters... 4

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Highly shock / vibration and soiling resistant Sturdy construction

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information