Page Page 23-17

Size: px
Start display at page:

Download "Page Page 23-17"

Transcription

1 Page -8 EERGY S Single phase, three phase with neutral, three phase with or without neutral irect connection or by current transformers MI certified versions Versions that can be expanded with EXP... expansion modules Versions with built-in RS485 communication port. Page -13 T CCETRTRS Energy consumption data storage for network usage Connection up to 14 energy meters equipped with static output Photovoltaic monitoring type Expandable with EXP... expansion modules Built-in RS485 communication port. Page -14 IGIT C MUTIS PWER YZERS Graphic or icon C Version with touch screen Modular and panel mount types Remote display Versions that can be expanded with EXP... expansion modules. Page -17 PRTBE PWER YZERS IP65 casing With built-in USB interface GPRS/GSM communications vailable kits of current clamps and cables. Page -18 E MESURIG ISTRUMETS Voltmeters, ammeters, frequency meters, cosphi meters and wattmeters. IGIT E MUTIS Basic version, with energy meters, with 2 programmable outputs and built-in RS485 communication port. CURRET TRSFRMERS Primary current: Secondary current: 5 Solid and split-core types Instrument and accuracy versions. Page -27

2 IG ISTRUMETS CURRET TRSFRMERS igital voltmeters, ammeters, wattmeters, frequency meters and cosphi meters igital multimeters and power analyzers, expandable, with graphic C Connection to single, two, three phase systems Ideal for distribution systems, electricity cogeneration and on-board machinery installations. High measurement accuracy Totally programmable digital outputs RS485, RS2, USB, Ethernet, Profibus P serial interface for remote control and data-logger. SEC. - PGE Energy meters Single phase Single phase, MI certified Three phase with or without neutral Three phase with neutral, MI certified Three phase with or without neutral, UTF certified ata concentrators General use For photovoltaic control and suvision igital metering instruments Modular C multimeters Flush mount C multimeters Flush mount touch-screen C power analyzers Flush mount E measuring instruments Flush mount E multimeters Modular E measuring instruments... - Communication devices, protection covers, accessories Converter gateway, connecting cables Current transformers imensions Wiring diagrams EERGY MGEMET

3 SYSTEM MGEMET MV/V transformer room MG EXP10 31 Energy Quality E MG EXP10 04 Temature control Primary distribution MG 800 ME 310 T2 (MI) MG 800 MG 700 MG MG 610 (MCC) M M M M Secondary distribution MG 300 MG 210 MG 200 MG EXP Process and ambient control MG 100 MG 110 ME 330 ME 310 T2 ME 300 T2 ME 100 T1 ME 110 T1 ME 115 T1 ME 120 T1 ME C -2

4 VT EECTRIC EVICE MITRIG Synergy ial-up connection Power analyser + GSM Modem (modbus SCII) Power factor controller Multimeter utomatic transfer switch RS485/Ethernet converter Energy meter Micro PC Soft starter Variable V speed drive Multimeter ME energy meter with pulse output Ethernet Process and environment data RS485 Electric signal -3

5 MG SERIES MUTIS ME SERIES EERGY S Energy quality verification Energy consumption monitoring Energy quality analysis according to E Water Pressure larms PT100 temature 4-20m 0-10V Process data collection Control and diagnostic Boolean logic combination -4

6 PHTVTIC ISTTI MGEMET C C ➁ ption ➀ for distinct values of: imported energy exported energy ME energy meter: EERGY PRUCE ➁ EECTRIC IE ➁ ME energy meter: EERGY CSUME EECTRIC PUSES IVERTER STTUS/RM ME C PV1 data concentrator views: Energy Produced Consumed Exchanged ➀ Self-consuming index Inverter alarms. ption for 2 loads disconnection by EXM10 01 Enabling / Commands ption for Ethernet connection by EXM10 03 ETHERET SMRTPHE PP: PV VIEW Router Contactors Internet PRIVIEGE S S THT C BE MGE aptop Suvision option remoted by cloud software (see Section 27) ➀ If the distinct values of import and export energy need to be known, a third energy meter should be installed on the in-coming line; the exchanged energy is the difference between import and export energy with the power supplier. ➁ The energy meters can be single or three phase based on the type of installation. -5

7 EERGY S - SIGE PHSE EERGY S - MUTIMESUREMET - SIGE PHSE Functions / Measurements ME M100 ME M100 T1 ME 100 T1 ME 110 T1 ME 115 T1 ME 120 T1 ME 121 ME 130 ISTTI Connection Single phase irect Through CT MV usage Built-in digital outputs Pulse Pulse Programmable Programmable Programmable Built-in digital inputs Built-in communication port RS485 Expandible with modules EX... type MI certified version Version with UTF certificates Current/Voltage accuracy ±0.5% ctive energy accuracy Class 1 (versions non MI) (IEC/E /22 or E ) Class B (versions MI) egree of protection IP40 MESUREMETS ctive energy Total Partial Reactive energy Total Partial Separate energy count Import - Export Voltage Current Power ctive power ctive power max demand max demand Power factor only Frequency Hour meter Cos TH (Total Harmonic istortion) etailed hamonic analysis Page -8/9-8/9-8 -8/9-8 EXPSI MUES igital inputs/outputs nalog inputs/outputs Communication ports Ethernet Gateway function GPRS-GSM modem Type of memory -6

8 EERGY S - MUTIMESUREMET - 3 PHSE MUTIS - PWER YZERS ME 300 T2 ME 301 ME 305 T2 ME 330 MG 100 MG 200 MG 300 MG 600 MG 610 MG 700 MG 800 MG 900 MG 900T ME 310 T2 MG 101 MG 210 MG 110 Three phase Single / Three phase (MEM 305 T2) 5 (MEM 310 T2) programm. programm. programm. (MG 101) programm. programm. programm. programm. programm. (MG 101) RS485 RS485 RS485 RS485 RS485 RS485 or (MG 110) (MG 210) RS2 (only ME 310 T2) (only ME 310 T2) (only ME 310 T2) ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.2% ±0.5% ±0.5% ±0.5% ±0.2% ±0.2% ±0.2% Class 1 Class 0,5S Cl. 1-Cl. B Class 0,5S Class 1 Class 1 Class 0,5S Class Class 1 Class 1 Class 0,5S Class 0,5S Class 0,5S Class B ME 310 T2 Cl. 0.5S ME 305 T2 IP40 IP40 IP54 IP to (only ME 310 T2) USB USB USB USB USB USB USB RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS485 RS485 RS485 RS485 RS485 RS485 RS485 Ethernet Ethernet Ethernet Ethernet Ethernet Ethernet Ethernet (only Profibus Profibus ME 310 T2) GPRS data connection (sms, mail, Client FTP) ata-ogger ata-ogger ata-ogger ata-ogger (only + ME 310 T2) Energy Quality E Class B -7

9 Energy meters Single phase, non expandable ME M100 ME 110 T1... ME 115 T1... ME 120 T ME 121 Single phase, expandable ME 130 EXM10 01 rder code escription Qty Wt pkg Mechanical meter with mechanical display. ME M direct connection, 1U ME M100 T1 32 direct connection, 1U pulse output igital meter, with C screen. ME 100 T1 40 direct connection, 1U pulse output, VC ME 100 T direct connection, 1U pulse output, VC ME 110 T1 40 direct connection, 1U program. static output, multimeasurements❶, VC ME 110 T direct connection, 1U program. static output, multimeasurements❶, VC igital meter with backlight C display. ME 115 T1 40 direct connection, 2U, program. static output, multimeasurements ❷, VC ME 120 T1 63 direct connection, 2U program. static output, multimeasurements ❶, VC ME 120 T direct connection, 2U program. static output, multimeasurements❶, VC ME direct connection, 2U, RS485 interface multimeasurements ❶, VC rder code escription Qty Wt pkg igital meter with backlight C display. ME direct connection, 2U, multi-measurements❶, expandable, VC rder code escription ME 130 EXPSI MUES. Inputs and outputs. EXM10 01 Maximum combination 2 opto-isolated digital inputs and 2 relay outputs 5 250VC ME 130 EXM10 01 MX 1 The energy meters are instruments for energy consumption measurement in single-phase installations with direct connection. ational characteristics ME M... (mechanical display) Rated supply voltage: 0VC % irect connection 32 maximum current ctive energy measurements ctive energy accuracy: Class 1 (IEC/E ) Mechanical meter with 6+1 digit count Flashing E for consumption indication Static pulse output for ME M100 T1 only Modular I housing, 1 module Sealable terminal blocks, standard supplied IEC degree of protection: IP40 on front; IP20 at terminals. ME 110T1 ME 110 T1 ME 115 T1 ME 120 T1 ME 121 ME 130 ominal supply voltage: VC for ME T C for ME T1 120 Voltage range: VC for ME... T VC for ME T1 120 irect connection Maximum current: 40 for ME 100 T1, ME 110 T1, ME 115 T1; 63 for ME 120 T1 ME 121 ME 130 ctive energy measurement and accuracy: Class 1 (IEC/E ) Reactive energy measurement and accuracy: Class 2 (IEC/E ) except for ME 115 T1 C meter : With 5+1 digit count for ME 100/110 T1 ; backlight with 6+1 digit count for ME 115 T1, ME 120 T1, ME 121, ME 130 Metrological E with pulse emission for consumption indication Clearable partial energy measurement except for ME 100/110 T1 ne output: Pulse for ME 100 T1; programmable static for all other types Built-in RS485 port for ME 121; compatible with Modular housing, 1 module for ME 100 T1, ME 110 T1; 2 module for all other types Sealable terminal blocks, standard supplied protection degree: IP40 on front; IP20 at terminals. suvision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (File E346886), as Electrical Process Control Equipment - Energy meters, for ME... types. Compliant with standards: IEC/E for ME M... type; E , IEC/E , U , CS C22.2 n for ME... types. ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. ❷ Multi-measurements: - Total and partial active energy - ctive power - verage active power (calculation on every last 15 minutes) - Maximum demand. -8 Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -33 pages -36 and 37

10 Energy meters MI certified Single phase, non expandable, MI certified MI ME 110 T1 MI ME 120 T1 MI rder code escription Qty Wt pkg igital meter with C display. ME 100 T1 MI 40 direct connection, 1U pulse output, 0VC ME 110 T1 MI 40 direct connection, 1U programmable static output, multi-measerements ❶, 0VC ME 120 T1 MI 63 direct connection, 2U programmable static output, multi-measerements ❶, 0VC The ME series energy meters, MI certified, are needed for billing purposes between electricity supplliers and consumers and for energy consumption measurement in directly connected single-phase installations. MI is the Measuring Instruments irective of the European Union; instruments must be certified accordingly whenever used for monetary transactions in this territory. ational characteristics ominal supply voltage: 0VC Voltage range: VC 50Hz irect connection Maximum current: 40 for ME 100/110 T1 MI; 63 for ME 120 T1 MI Measurement of 14 electrical parameters for ME 110/120 T1 MI ctive energy measurement and accuracy: Class B (E ) Reactive energy measurement and accuracy: Class 2 (IEC/E ) C meter: With 5+1 digit count for ME 100/110 T1 MI Backlight with 6+1 digit count for ME 120 T1 MI Metrological E with pulse emission for consumption indication Clearable partial energy measurements (except for ME 100 T1 MI) ne output: pulse for ME 100 T1 MI; programmable static for other types Modular housing, 1 module for ME 100/110 T1 MI; 2 module for ME 120 T1 MI Sealable terminal blocks, standard supplied E protection degree: IP40 on front; IP20 at terminals. Certifications and compliance Certifications obtained: MI Class B, certifications module B (type tests) and module (production conformity). Compliant with standards: E , E ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. imensions page -30 Wiring diagrams page -33 pages -36 and 37-9

11 Energy meters Three phase with or without neutral, non expandable ME 300 T2 ME 330 Three phase with or without neutral, expandable ME 310 T2 EXM10 10 rder code escription Qty Wt pkg igital meter for three phase with neutral. ME 300 T2 63 direct connection, U, 2 programmable static outputs, multi-measurements ❶ ME direct connection, 4U RS485 interface, multi-measurements❶ ME 305 T2 Connection by CT /5, U, 2 programmable static outputs, multi-measurements❶ igital meter for three phase with or without neutral. ME 330 Connection by CT / sec. 4U, RS485 interface, multi-measurements❶ rder code escription Qty Wt pkg igital meter for three phase with or without neutral. ME 310 T2 Connection by CT / secondary, 2 programmable static outputs, 4U, C graphic display multimeasurements ❶, expandable rder escription code ME 310 T2 EXPSI MUES. Inputs and outputs. EXM digital inputs and 2 static outputs, opto-isolated EXM opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 EXM10 11 EXM10 12 EXM10 13 EXM10 20 EXM10 30 pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface Ethernet interface with Web server function pto-isolated RS485 interface and 2 relay outputs rated 5 250VC ata storage, clock-calendar (RTC) with backup reserve energy for data logging The energy meters are digital meters/analyzers of electric energy for systems with direct three-phase connection or by CT. Expandable with up to 3 EXM series interfaced by infrared beam. ational characteristics ominal supply voltage: VC (-) for ME 300 T2, ME 310 T2, ME 330 and ME VC (-) for ME 301 Voltage range: VC (-) for ME 300 T2, ME 310 T2, ME 330 T2 and ME VC (-) for ME 301 irect connection 63 for ME 300 T2 and 80 for ME 301 Connection by T /5 or 1 for ME 310 T2, ME 330 and ME 305 T2 ctive energy measurement and accuracy: Class 0,5s (IEC/E ) for ME 301, ME 305 T2 and ME 330 Class 1 (IEC/E ) for other types. ctive energy measurement and accuracy: Class 2 (IEC/E ) C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial active energy measurements 1 programmable digital input 2 programmable static outputs except ME 330 and ME 301 Built-in RS485 port for ME 330 and ME 301 and optional for ME 310 T2; compatible with and ptic interface for EXM10... expansion modules with ME 310 T2 Modular housing, 4 module Sealable terminal blocks, standard supplied egree of protection: IP40 on front; IP20 at terminals. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXM series expansion modules See page Certifications and compliance Certifications obtained: EC. Compliant with standards: E , IEC/E ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. Maximum combination MX 3-10 Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -33 page -38

12 Energy meters MI certified Three phase with neutral, non expandable, MI certified MI ME 300 T2 MI Three phase with or without neutral, expandable, MI certified MI ME 310 T2 MI EXM10 10 rder code escription Qty Wt pkg igital meter for three phase with neutral. ME 300 T2 MI 63 direct connection, programmable static outputs, multi-measurements❶ rder code escription Qty Wt pkg igital meter for three phase with or without neutral. ME 310 T2 MI Connection by CT / secondary, 2 programmable static outputs, C graphic display multimeasurements ❶, expandable rder escription code ME 310 T2 MI EXPSI MUES. Inputs and outputs. EXM digital inputs and 2 static outputs, opto-isolated EXM opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 EXM10 11 EXM10 12 EXM10 13 EXM10 20 EXM10 30 Maximum combination pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface Ethernet interface with Web server function pto-isolated RS485 interface and 2 relay outputs rated 5 250VC ata storage, clock-calendar (RTC) with backup reserve energy for data logging The ME series energy meters, MI certified, are needed for billing purposes between electricity suppliers and consumers and for energy consumption measurement in directly or CT connected three-phase installations. Expandable with up to 3 EXM series interfaced by infrared beam. ational characteristics ominal supply voltage: 0VC (-); 400VC (-) Voltage range: VC (-); 3-456VC (-) irect connection 63 for ME 300 T2 Connection by CT /5 for ME 310 T2 MI ctive energy measurement and accuracy: Class B (E ) Reactive energy measurement and accuracy: Class 2 (IEC/E ) C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial energy measurements 1 programmable digital input 2 programmable static outputs ptic interface for EXM10... expansion modules with ME 310 T2 MI compatible with and Modular housing 4 module Sealable terminal blocks, standard supplied egree of protection: IP40 on front; IP20 at terminals. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXM series expansion modules See page Certifications and compliance Certifications obtained: MI Class B (E , E ), certifications module B (type tests) and module (production conformity). Compliant with standards: E , E ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. MX 3 Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -33 page

13 Energy meters MI certified With UTF certificates Three phase with neutral, non expandable, MI certified ME 300 F Three phase with or without neutral, expandable, MI certified ME 310 F... EXM10 10 rder code escription Qty Wt pkg igital meter for three phase with neutral, complete with UTF certificates for installations in Italy. ME 300 F MI certified type, direct connection, 4U, 2 programmable static outputs, non expandable, multi-measurements, complete with UTF certificate rder code escription of CTs included Qty Wt pkg Kit comprising 1 ME310T2MI type MI 4U digital counter and three /5 and class 0.5s current transformers. ME 310 F060 60/5 type M1TP ME 310 F080 80/5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M1TP ME 310 F /5 type M3TP ME 310 F /5 type M3TP ME 310 F /5 type M3TP ME 310 F /5 type M5TP ME 310 F /5 type M5TP ME 310 F /5 type M5TP ME 310 F /5 type M5TP ME 310 F /5 type M5TP ME 310 F /5 type M5TP rder code escription ME 310 F EXPSI MUES. Inputs and outputs. EXM digital inputs and 2 static outputs, opto-isolated EXM opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 EXM10 11 EXM10 12 EXM10 13 EXM10 20 pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface pto-isolated Ethernet interface pto-isolated RS485 and 2 relay outputs rated 5 250VC The ME series energy meters, MI certified, are needed for billing purposes between electricity suppliers and consumers and for energy consumption measurement in directly or CT connected three-phase installations. Expandable with up to 3 EXM series expansion modules interfaced by infrared beam ME 310 F... The UTF certificate is required in the case of taxation in Italy (electricity-generating installations). ational characteristics ME 300 F - ME 310 F... of starter kit ominal supply voltage: 0VC (-); 400VC (-) Voltage range: VC (-); 3 456VC (-) irect connection 63 for ME 300 F Connection by CT /5, standard supplied, for ME 310 F... ctive energy measurement and accuracy: Class B (E ) Reactive energy measurement and accuracy: Class 2 (IEC/E ) C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial energy measurements 1 programmable digital input 2 programmable static outputs ptic interface for EXM series expansion modules with ME 310 F... compatible with and Modular housing 4 module Sealable terminal blocks, standard supplied egree of protection: IP40 on front; IP20 at terminals. Multi-measurements Total and partial active energy Total and partial reactive energy Voltage Current ctive and reactive power Power Factor Frequency Total and partial hour counter verage active power (calculation on every last 15 minutes) Maximum demand. M5T CURRET TRSFRMERS ating frequency: 50 60Hz Secondary output current: 5 verload withstand: 120% Ipn Rated insulation voltage Ui: 720V Rated short time thermal current Ith: 40-60Ipn for 1 second Rated dynamic current Idyn: 2.5Ith for 1 second Insulation (dry type): class E Screw fixing terminals Standard supplied sealable terminal covers and fixing elements E degree of protection: IP30. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXM series expansion modules See page Maximum combination MX 3 Certifications and compliance Certifications obtained: MI Class B (E , E ), certifications module B (type tests) and module (production conformity) for ME 300 F and ME 310F energy meters. UTF certificates for the ME 300F and for each component of the starter kits are standard supplied. Compliant with standards: E , E for ME 300 F and ME 310 T2 MI; IEC/E for M5T Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -33 page -38

14 ata concentrators Expandable rder code escription Qty Wt pkg ME C - ME C PV1 EXM10 10 ata concentrator for general use. ME C With 8 programmable digital inputs, expandable, for data collection + pulse count from MEM100T1 and ME, RS485 port ata concentrator for photovoltaic applications. ME C PV1 Programmed for installation control and data collection+pulse count from two ME❶ minimum, RS485 port, expandable ❶ Except ME 100 T1. rder code escription ME C ME C PV1 EXPSI MUES. Inputs and outputs. EXM digital inputs and 2 static outputs, opto-isolated EXM opto-isolated digital inputs and 2 relay outputs rated 5 250VC EXM opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 EXM10 11 EXM10 12 EXM10 13 EXM10 20 EXM10 30 Maximum combination pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface Ethernet interface with Web server function pto-isolated RS485 interface and 2 relay outputs, rated 5 250VC ata storage, clock-calendar (RTC) with backup reserve energy for data logging ME C is equipped with 8 inputs, which can be increased up to a maximum of 14 and allows to indirectly interface devices without communication as long as they have at least one pulse output. It is capable of pulse counting that come in from the outputs of meters for energy, water, gas and other types of consumption: ll data is viewed on its display or can also be available for PCs through its built-in RS485 interface using or software. It can be expanded with up to 3 EXM series modules by optical interface. With the programmable functions, average values can be determined for instantaneous quantities, such as power, speed, production rate, gas and water consumption, etc. ME C PV1 is specific for the monitoring of solar installations and needs to be connected to at least two ME meters (single or three phase). The user can available of data, such as energy produced by the generating installation, energy consumed by loads as well as exchanged energy (difference between import and export energy) with the power supplier. It is already programmed to automatically calculate the self-consuming index and autonomy, mean power values, production (total and partial values) and the oating status of the C/C inverter, if it is equipped with digital outputs. In addition, it can be customised by the user for load suvision, using the EXM series expansion modules, according to the defined logics and on the basis of the energy available. ational characteristics ominal supply voltage: VC/ VC Voltage range: VC/93, VC Backlight graphic C 8 inputs, expandable with EXM 10 modules up to 14 Built-in RS485 communication port Modbus-RTU, SCII and TCP communication protocol Multifunction display Clearable total and partial counters for each channel Programmable general counters Calculation of derivative average values Mathematical oations among counters Modular housing, 4 module IEC degree of protection: IP40 on front; IP20 at terminals. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXM series expansion modules See page MX 3 Certifications and compliance Certifications obtained: EC for all; U listed for US and Canada (cuus File E346886), as Electrical Process Control Equipment ata concentrator for MEC; pending for MECPV1 and MEKITCPV1100. Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -33 page

15 Metering instruments and current transformers igital measuring instruments. Starter kits Modular C multimeters non expandable MG 1... MG MG 210 rder escription Qty Wt code pkg. MG 100 Icon C, auxiliary supply VC/ VC. Multilanguage: Italian, English, French, Spanish, Portuguese and German MG 101 Icon C, auxiliary supply VC/ VC. 2 digital inputs and 2 outputs. Multilanguage: Italian, English, French, Spanish, Portuguese and German MG 110 Icon C, RS485 port, auxiliary supply VC/ VC. Multilanguage: Italian, English, French, Spanish, Portuguese and German MG 200 Graphic 128x80 pixel C, auxiliary supply VC/ VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x80 pixel C, auxiliary supply VC/ VC. Multilanguage: English, Czech, Polish, German and Russian MG 210 Graphic 128x80 pixel C, RS485 port, auxiliary supply VC/ VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x80 pixel C, RS485 port, auxiliary supply VC/ VC. Multilanguage: English, Czech, Polish, German and Russian Starter kits rder code escription Qty Wt pkg MG KIT MG KIT Composed of one MG 100 multimeter and n 3 CTs 60/5 for Ø22mm cable MG KIT Composed of one MG 100 multimeter and n 3 CTs 100/5 for Ø22mm cable MG KIT Composed of one MG 100 multimeter and n 3 CTs 150/5 for Ømm cable MG KIT Composed of one MG 100 multimeter and n 3 CTs 200/5 for Ømm cable MG... digital multimeters are available with a modular housing, 4 module size, and are equipped with a graphic backlight C (except MG 100/101/110 with icon display) capable of providing extremely clear, intuitive and flexible viewing of all electrical parameters of an installation. For MG 110 and MG 210 versions, there is a built-in isolated RS485 interface, while MG 101 features 2 programmable digital inputs and 2 outputs. Main measurements: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor phase and total Frequency of measured voltage value HIGH-W-VERGE value functions of all measurements Maximum demand of power and current values symmetric voltage and current Total harmonic distortion (TH) of voltage and current values Energy meters for active, reactive and apparent values Hour counter (total and partial, 1 on MG 200/210, 4 programmable on MG 100/101/110) Phase energy (MG 100/110) Harmonic analysis up to the 15th order (MG 100/110). ational characteristic uxiliary supply voltage range: VC / 93, VC Maximum rated measurement voltage 600VC (MG 100/101/110) 690VC (MG 200/210) Voltage measurement range: VC phase-to-phase (MG 100/101/110) VC phase-to-phase (MG 200/210) Usage in medium and high-voltage systems with voltage transformers Rated input current: With external CT /5 (also 1 for MG 100/101/110) Current measurement range with CT up to 10,000 Frequency measurement range: 45-66Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0,5% ( VC for MG 1...) ( VC) for MG 2... Current: ±0,5% (0,1...1,1In) Power: ±1% f.s. Frequency: ±0,05% ctive energy: Class 1 (IEC/E ) Reactive energy: Class 2 (IEC/E ) on-volatile memory for data storage Communication protocol Modbus-RTU and SCII (only for MG 210 and MG 110) Programming and remote control by software (only for MG 210 and MG 110; compatible with and software) Modular housing, 4 module egree of protection: IP40 on front; IP20 at terminals. CURRET TRSFRMERS F MG KITS ating frequency: 50 60Hz Secondary output current: 5 verload withstand: 120% Ipn Rated insulation voltage Ui: 720V Rated short time thermal current Ith: 40 60Ipn for 1 second Rated dynamic current Idyn: 2.5Ith for 1 second Insulation (dry type): class E Faston terminals egree of protection: IP30. suvision and energy management software See Section 27. configuration and remote control software See Section 27. Certifications and compliance Certifications obtained: EC for all; U isted for US and Canada (cuus - File E93601), as uxiliary evices - Multimeter for MG 1.../MG 2... types. Compliant with standards: IEC/E , IEC/E , IEC/E ; U , CS C22.2 n for MG 100/110 (MG 101 pending); U508, CS C22.2 n 14 for MG 200/210; IEC/E for transformers of starter kits. -14 Software and accessories pages -25 and 26 imensions page -30 Wiring diagrams page -34 page -40

16 igital measuring instruments Modular C multimeters expandable MG 300 EXM10 10 rder escription Qty Wt code pkg MG 300 Graphic 128x80 pixel C, harmonic analysis, auxiliary supply VC/ VC, expandable with modules series EXM... Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x80 pixel C, harmonic analysis, auxiliary supply VC/ VC, expandable with modules series EXM... Multilanguage: English, Czech, Polish, German and Russian rder escription code MG 300 MG EXPSI MUES. Inputs and outputs. EXM10 00 EXM10 01 EXM10 02 Communication ports. EXM10 10 EXM10 11 EXM10 12 EXM10 13 EXM10 20 EXM10 30 Maximum combination 2 digital inputs and 2 static outputs, opto-isolated 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC 4 opto-isolated digital inputs and 2 relay outputs rated 5 250VC pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface Ethernet interface with Web server function pto-isolated RS485 interface and 2 relay outputs rated 5 250VC ata storage, clock-calendar (RTC) with backup battery for data logging MX 3 MG 300 digital multimeters are available with a modular housing, 4 module size, and are equipped with a graphic backlight C capable of providing extremely clear, intuitive and flexible viewing of all electrical parameters of a system. The very accurate measurements combined with their extreme compactness provide an ideal solution for every type of application. Expandable with up to 3 EXM series modules interfaced by infrared beam. Main measurements: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor phase and total Frequency of measured voltage value HIGH-W-VERGE value functions for all measuements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion (TH) of voltage and current values Harmonic analysis of voltage and current up to 31 order Energy meters for active, reactive, apparent partial and total values, programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc. with expansion module only. ational characteristics uxiliary supply voltage range: VC / VC Voltage measurement range: VC phase-to-phase VC phase-neutral Usage in medium and high-voltage systems with voltage transformers Rated input current: With external CT, 5 or 1 Current measurement range with CT up to 10,000 Frequency measurement range: 45-66Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0.2% (50-830VC) Current: ±0.2% ( In) Power: ±0.5% f.s. Power factor: ±0.5% Frequency: 0.05% ctive energy: Class 0.5S (IEC/E ) Reactive energy: Class 2 (IEC/E ) on-volatile memory for data storage Communication protocol Modbus - RTU, SCII and TCP (only with communication expansion modules) Programming and remote control by software (only with communication expansion modules); compatible with and software Modular housing, 4 module egree of protection: IP40 on front; IP20 at terminals. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXM10 series expansion modules See page Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices - Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U508, CS C22.2 n 14. Software and accessories pages -25 and 26 Expansion modules page 28-3 imensions page -30 Wiring diagrams page -34 page

17 igital measuring instruments Flush mount C multimeters, expandable MG MG 610 MG MG MG M EXP10... rder escription Qty Wt code pkg MG 600 Backlight icon C 72x46mm harmonic analysis, auxiliary supply VC/ VC, front optical port. Multilanguage: Italian, English, French, Spanish, Portuguese and German. MG 610 Backlight icon 72x46mm harmonic analysis, auxiliary VC/120 supply 250VC, built-in RS485 front optical serial port. Multilanguage: Italian, English, French, Spanish, Portuguese and German MG 700 Graphic 128x80 pixel C, auxiliary supply VC/ VC Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x80 pixel C, auxiliary supply VC/ VC Multilanguage: English, Czech, Polish, German and Russian MG 800 Graphic 128x80 pixel C, harmonic analysis, auxiliary supply VC/ VC Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x80 pixel C, harmonic analysis, auxiliary supply VC/ VC Multilanguage: English, Czech, Polish, German and Russian MG Graphic 128x80 pixel C, harmonic analysis, auxiliary supply VC MG M MG 800 portable unit in M3 case, prewired, for mobile applications, with USB port, without external cable (see p. -26) rder escription code MG600/610, MG700, MG800 EXPSI MUES Inputs and outputs. EXP opto-isolated digital inputs EXP10 01 EXP10 02 EXP10 03 EXP10 04 EXP opto-isolated static outputs 2 digital inputs and 2 static outputs, opto-isolated 2 relay outputs rated 5 250VC 2 opto-isolated analog inputs 0/4-20m or PT100 or 0-10V or 0...±5V for MG opto-isolated analog outputs 0/4-20m or 0-10V or 0...±5V for MG 800 EXP opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXP10 10 EXP10 11 EXP10 12 EXP10 13 EXP10 14 EXP10 30 pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface pto-isolated Ethernet interface with web server function pto-isolated Profibus-P interface for MG 800 ata storage, clock-calendar (RTC) with backup reserve energy for data logging for MG 800 MG 600/610, MG 700 and MG 800 digital multimeters are capable of viewing the measurements with high accuracy on the wide graphic C, which allow to control energy distribution networks. They are available with a flush-mount housing, (96x96mm/3.78 x3.78 ) and expansion slots to fit plug-in expansion modules (1 for MG 600/610 and 4 for MG 700/800), suitable for numerous applications. The main features include an extended power supply voltage range, high measurement accuracy, expandability and graphic interactive interface for simple use. Main measurements: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor phase and total Frequency of measured voltage value HIGH-W-VERGE value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion (TH): voltage and current Harmonic analysis of voltage and current up to the 15 (MG 600/610) and 31 order (only MG 800) Energy meters for active, reactive, apparent partial and total values Programmable tariff functions (only MG 700/800) Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc., with expansion module only MG 700/800. ational characteristics uxiliary supply voltage range: VC / 93, VC MG 600/610/700/ VC MG Voltage measurement range: VC - / MG 700/ VC - MG 600/610 Usage in medium and high voltage systems with voltage transformers Rated input current: By external CT 5 for MG 700; By external CT 5 or 1 for MG 600/610, MG 800 Frequency measurement range Hz True RMS measurements: for voltage and current Measurement accuracy for MG 600/610-MG 700: Voltage: ±0,5% ( VC MG 600/610; VC MG 700) Current: ±0,5% (0,1...1,1In) Power: ±1% f.s. Frequency: ±0,05% ctive energy: Classe 1 (IEC/E ) Reactive energy: Class 2 (IEC/E ) Measurement accuracy for MG 800..: Voltage: ±0,2% ( VC) Current: ±0,2% (0,1...1,1In) Power: ±0,5% f.s. Power factor: ±0,5% Frequency: ±0,05% ctive energy: Class 0,5s (IEC/E ) Reactive energy: Class 2 (IEC/E ) on-volatile memory for data storage Communication protocol Modbus-RTU, SCII and TCP Compatible with and software Flush-mount housing 96x96mm/3.78 x3.78 egree of protection: n front IP54 MG 600/610; IP65 all others. ll IP20 at terminals. verall M3 case dimensions: See page suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXP series expansion modules See page Certifications and compliance Certifications obtained: EC for all except MGM380001; U listed for US and Canada (cuus File E93601), as uxiliary evices Multimeters for MG types pending for MG600/610 and excluding MGM Compliant with standards: IEC/E , IEC/E , IEC/E , U508, CS C22-2 n Software and accessories pages -25 and 26 Expansion modules page 28-2 imensions page -30 Wiring diagrams page -34 page -41

18 igital measuring instruments Flush mount C touchscreen power analyzers, expandable MG MG M MG 900T... MG 900R EXP10... rder escription Qty Wt code pkg. MG 900 Graphic 128x112 pixel touch-screen C, harmonic analysis, 4 current channels, (neutral meas.), VC/ VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG Graphic 128x112 pixel touch-screen C, harmonic analysis, 4 current channels, (neutral meas.), VC/ VC. Multilanguage: English, Czech, Polish, German and Russian MG Graphic 128x112 pixel touch-screen C, harmonic analysis, 4 current channels, auxiliary supply VC MG M MG 900 portable unit in M3 case, prewired for mobile applications, with USB port, without external cables (see page -26) MG 900T Measurement transducer, harmonic analysis, 4 current channels (neutral meas.), VC/ VC, RS2 and RS485 ports ❶ MG 900T 048 Measurement transducer, harmonic analysis, 4 current channels (neutral meas.), VC, RS2 and RS485 ports ❶ Remote display for MG 900T... MG 900R Graphic 128x112 pixel touch screen C, with 3m long connecting cable❷ ❶ o simultaneous oations of serial ports. Consult Customer Service for information (Tel ; service@ovatoelectric.com) or the instructions manual. ❷ irect link to MG 900T dedicated port: powered directly by MG 900T. rder escription code MG 900 and MG 900 T EXPSI MUES. Inputs and outputs. EXP10 00 EXP10 01 EXP10 02 EXP10 03 EXP10 04 EXP opto-isolated digital inputs 4 opto-isolated static outputs 2 digital inputs and 2 static outputs, opto-isolated 2 relay outputs rated 5 250VC 2 opto-isolated analog inputs 0/4-20m or PT100 or 0-10V or 0...±5V 2 opto-isolated analog outputs 0/4-20m or 0-10V or 0...±5V EXP opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXP10 10 EXP10 11 EXP10 12 EXP10 13 EXP10 14 EXP10 15 EXP10 30 pto-isolated USB interface pto-isolated RS2 interface pto-isolated RS485 interface pto-isolated Ethernet interface with Web server function pto-isolated Profibus-P interface GPRS/GSM modem, without antenna ata storage, clock-calendar (RTC) with backup reserve energy for data logging EXP10 31 ata storage, with Energy Quality (E class B), clock-calendar (RTC) with backup reserve energy for data logging MG expandable digital power analyzers are available with a flush-mount housing, 96x96mm/3.78 x3.78. The wide graphic touch screen display provides extremely simple interacting between the device and the user. The high formance of the power analyzers gives very accurate measurements and can control energy distribution networks, to detect and prevent energy problems which could compromise quality and supply. The main features include an extensive power supply voltage range, high measurement accuracy, expandability up to 4 plug in expansion modules. There also is available the MG 900T measurement transducer which can be used with the MG 900R remote display. The MG 900T, without display, is arranged for mounting inside the panel board, on 35mm I rail, and is an ideal solution for installations where the measurements of various multimeters must be remotely viewed. The MG 900R remote display connected to the MG 900T transducer can display the measurements on the panel front while power connections remain inside the panel. Main measurements and functions include: Voltage: phase, phase-neutral and ground neutral-earth Supply voltage value (only MG ) Current: phase values eutral current calculated and true values Power: apparent, active and reactive phase and total values P.F.: Power Factor phase and total Cos phase and total Frequency of measured voltage value Voltage and current asymmetry Total harmonic distortion (TH) of voltage and current Harmonic analysis of voltage and current up to the 63 order HIGH-W-VERGE value functions for all measurements Maximum demand of power and current values Energy meters for active, reactive, apparent partial and total values with programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc., with expansion module only Energy quality analysis to E Class B (with expansion module). ational characteristics uxiliary supply voltage range: VC / 93, VC for MG 900 and MG 900T; VC for MG and MG 900T 048 Voltage measurement range: VC phase-to-phase VC phase-neutral Usage in medium and high-voltage systems with voltage transformers rated input current: 5 or 1 via CT Current measurement range: 0, o 0, Current measurements via CT up to 10,000 Frequency measurement range: Hz / Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0,2% ( VC) Current: ±0,2% ( In) Power: ±0,5% f.s. Power factor: ±0,5% Frequency: ±0.05% ctive energy: Class 0.5s (IEC/E ) Reactive energy: Class 2 (IEC/E ) on-volatile memory for data and event (last 100) storage Communication protocol Modbus-RTU, SCII and TCP with communication expansion modules only Programming and remote control by software with communication expansion modules only Housing: 96x96mm/3.78 x3.78 flush mount (for MG and MG 900R) and 35mm I rail (for MG 900T...) egree of protection: IP65 on front for MG MG 900R; IP20 at terminals for MG MG 900T. suvision and energy management software See Section 27. configuration and remote control software See Section 27. EXP series expansion modules - See page Certifications and compliance Certifications obtained: EC for all except MG M3...; U isted, for US and Canada (cuus - File E93601), as uxiliary evices-multimeters for all except MG M3... Compliant with standards: IEC/E , IEC/E , IEC/E , U 508, CS C22.2 n 14. Software and accessories pages -25 and 26 Expansion modules page 28-2 imensions page -30 Wiring diagrams page -34 page

19 igital measuring instruments Flush-mount E instruments single phase non expandable MK 0... rder isplayed Relay Qty Wt code measurements output pkg n n Voltmeter. MK 00 1 voltage value MK 00 R1❷ 1 max voltage value 1 min voltage value mmeter. MK 01 1 current value MK 01 R1❷ 1 max current value 1 min current value Voltmeter or ammeter. MK 02❶ 1 voltage or current value 1 maximum voltage or current value 1 minimum voltage or current value Frequency meter. MK 03 1 frequency value MK 03 R1❷ 1 max frequency value 1 1 min frequency value Cosphi meter. MK 04 1 cosphi value MK 04 R1❷ 1 power factor value ❶ The MK02 can oate as a voltmeter or ammeter. It is duly equipped with two front plates (V and ) which must be fitted by the user depending on which instrument is required and on the wiring scheme used. ❷ Relay output for control and protection functions. The MK 0... instruments are available with flush-mount housing, 96x48mm/3.78x1.89. Measurements are True RMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC; ating frequency: 50-60Hz True RMS measurements Max. and Min. measurement storage 1 relay output with 1 changeover contact (for MK...R1 only) Housing: Flush mount 96x48mm/3.78x1.89 Terminals: 4mm 2 egree of protection: IP54 on front; IP20 at terminals. MK 00 - MK 00 R1 Voltage measurement range: VC ating frequency range: 45-65Hz Programmable VT ratio: ccuracy: ±0.25% f.s. ±1 digit MK 01 - MK 01 R1 Current measurement range: ating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 02 Voltage measurement range: VC Current measurement range: ating frequency range: 45-65Hz Programmable VT ratio: Programmable CT ratio: FF/5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit MK 03 - MK 03 R1 Measurement input: VC Frequency measurement range: 15-65Hz ccuracy: ±1 digit MK 04 - MK 04 R1 Cosphi measurement error: ±0.5 ±1 digit Cosphi measurement in 4 quadrants ccuracy: ±1 ±1 digit Control and protection functions MK 00 R1 Voltage loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% Time delay for max-min voltage or voltage loss, phase loss ❸: seconds. MK 01 R1 Current loss: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% Time delay for max-min current or current loss ❸: seconds. MK 03 R1 Maximum frequency: FF/ % Minimum frequency: FF/90-99% Time delay for min-max frequency ❸: seconds. MK 04 R1 Minimum-maximum cos thresholds in 4 quadrants Minimum-maximum PF thresholds in 4 quadrants elay time for max or min threshold ❸: 1-9,000 seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U 508, CS C22.2 n 14. ❸ Independent adjustable delays. -18 ccessories page -25 imensions page -30 Wiring diagrams page -35 page -42

20 igital measuring instruments Flush-mount E instruments three phase non expandable MK 1... rder isplayed Relay Qty Wt code measurements output pkg n n Voltmeter. MK 10 3 phase voltage values MK 10 R1❷ 3 phase to phase voltage values maximum phase voltage values 3 maximum phase to phase voltage values 3 minimum phase voltage values 3 minimum phase to phase voltage values mmeter. MK 11 3 phase current values MK 11 R1❷ 3 maximum phase current values minimum phase current values Voltmeter, ammeter and wattmeter. MK 15 3 phase voltage values MK 15 R1❶❷ 3 phase to phase voltage values phase current values 4 active power values, phase and total 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 maximum active power values, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 minimum active power values, phase and total ❶ Connection also to single phase. ❷ Relay output for control and protection functions. The MK 1... instruments are available with flush-mount housing, 96x48mm/3.78x1.89. Measurements are TRMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC; ating frequency: 50-60Hz TRMS measurements Max and Min measurement storage 1 relay output with 1 changeover contact (for MK...R1 only) Housing: Flush mount 96x48mm/3.78x1.89 Terminals: 4mm 2 egree of protection: IP54 on front; IP20 at terminals. MK 10 - MK 10 R1 Voltage measurement range: VC ating frequency range: 45-65Hz Programmable VT ratio: ccuracy: ±0.25% f.s. ±1 digit. MK 11 - MK 11 R1 Current measurement range: ating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit. MK 15 - MK 15 R1 Voltage measurement range: VC Current measurement range: Frequency measure range: 45-65Hz Programmable VT ratio: Programmable CT ratio: 5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit Power ±1% f.s. ±1 digit. Control and protection functions MK 10 R1 Phase loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Frequency Maximum frequency: FF/ % Minimum frequency: FF/90-99% Time delay for max-min voltage, phase loss, asymmetry and min-max frequency ❸: seconds. MK 11 R1 Current loss: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% symmetry: FF/2-20% Time delay for max-min current or current loss and asymmetry ❸: seconds. MK 15 R1 Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Current loss: FF/5-85% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% symmetry: FF/2-20% Power Rated power: 1-10,000 Maximum power: FF/ % Max. power instantaneous tripping: FF/ % Minimum power: FF/10-99% Frequency Maximum frequency: FF/ % Minimum frequency FF/90-99% Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power ❸: seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U 508, CS C22.2 n 14. ❸ Independent adjustable delays. ccessories page -25 imensions page -30 Wiring diagrams page -35 page

21 igital measuring instruments Flush-mount E multimeter three phase non expandable MK 16 rder isplayed Qty Wt code measurements pkg MK 16 3 phase voltage values phase to phase voltage values 3 phase current values 4 active power values, phase and total 4 reactive power values, phase and total 4 apparent power values, phase and total 3 phase power factor values 1 frequency value 1 active energy value in kwh 1 reactive energy value in kvarh 1 hour counter 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 maximum active power values, phase and total 4 maximum reactive power values, phase and total 4 maximum apparent power values, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 minimum active power values, phase and total 4 minimum reactive power values, phase and total 4 minimum apparent power values, phase and total The MK 16 multimeter is available with flush-mount housing, 96x48mm/3.78x1.89. Measurements are True RMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC; ating frequency: 50-60Hz True RMS measurements ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit ctive energy accuracy: Class 2 (IEC/E and IEC/E ) Max and Min measurement storage Voltage measurement range: VC Current measurement range: ating frequency range: 45-65Hz Programmable VT ratio: Programmable CT ratio: 5-10,000 Housing: Flush mount 96x48mm/3.78x1.89 Terminals: 4mm 2 egree of protection: IP54 on front; IP20 at terminals. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U508, CS C22.2 n ccessories page -25 imensions page -30 Wiring diagrams page -35 page -44

22 igital measuring instruments Flush-mount E multimeter three phase non expandable MK 16 R1 rder escription Qty Wt code pkg MK 16 R1❶ 3 phase voltage values phase to phase voltage values 3 phase current values 4 active power values, phase and total 4 reactive power values, phase and total 4 apparent power values, phase and total 3 phase power factor values 1 frequency value 1 active energy value in kwh 1 reactive energy value in kvarh 1 hour counter 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 maximum active power values, phase and total 4 maximum reactive power values, phase and total 4 maximum apparent power values, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 minimum active power values, phase and total 4 minimum reactive power values, phase and total 4 minimum apparent power values, phase and total 2 minimum and maximum power factor values ❶ Connection also to single phase. The MK 16 R1 multimeter is available with flush-mount housing, 96x48mm/3.78x1.89 Measurements are True RMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC ating frequency: 50-60Hz True RMS measurements ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit ctive energy accuracy: Class 2 (IEC/E and IEC/E ) Max and Min measurement storage Voltage measurement range: VC Current measurement range: Frequency measurement range: 45-65Hz Programmable VT ratio: Programmable CT ratio: 5-10,000 1 relay output with 1 changeover (SPT) contact Housing: Flush mount 96x48mm/3.78x1.89 Terminals: 4mm 2 egree of protection: IP54 on front; IP20 at terminals. PRGRMMBE REY UTPUT Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Protection inhibition max current: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% symmetry: FF/2-20% Power factor Maximum power factor: Minimum power factor: Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power factor ❷: seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U 508, CS C22.2 n 14. ❷ Independent adjustable delays. ccessories page -25 imensions page -30 Wiring diagrams page -35 page

23 igital metering instruments Flush mount E multimeters non expandable 47 electrical parameters MK 2... rder code escription Qty Wt pkg. MK 20 Basic version, auxiliary supply VC MK 21 Version with energy meters included, auxiliary supply VC MK 22 Version with energy meters and RS485 port included, auxiliary supply VC MK 2... digital multimeters are available with flush-mount housing, 96x96mm/3.78x3.78. They monitor and view reliable readings of electrical parameters, even in the presence of critical oating conditions, such as voltages and currents with high harmonic content and variable frequency. The total and partial hour counter provides an interesting feature for electric panels of emergency generating sets. The diversified and accurate measurements give the multimeters valuable technical and cost effective advantages with respect to traditional analog instrumentation. MK2... digital multimeters view 47 electrical parameters: Voltage: phase, line and system values Current: phase values Power: active and reactive values, apparent phase. P.F.: power factor phase Frequency (measured voltage frequency) HIGH/W: instantaneous minimum and maximum values of each phase voltage and current, total active power ( W), total reactive power ( var) and total apparent power ( V) values Total hours: non-volatile clearable log for MK 20 Partial hours: non-volatile configurable log for MK 20 ctive and reactive energy meters for MK21 and MK22 only. ational characteristics uxiliary supply voltage range: VC for MK VC for MK 21-MK 22 Voltage measurement range: VC phase-phase VC phase-neutral Current measurement range: Frequency measurement range: 45-65Hz Programmable CT ratio: 1.0-2,000 Voltage accuracy: Class 0.5 ±0.35% f.s. (830V) Current accuracy: Class 0.5 ±0.5% f.s. (6) ctive energy accuracy: Class 2 Total and partial hour counter (can be used as maintenance with optical alarm and separate resetting) (MK 20) HIGH and W value functions to read and log instantaneous voltage, current and power values elayed automatic resetting of default measurements veraging function to slow down repetitive fluctuations to obtain more stable readouts Current connection in R configuration by 2 current transformers (CTs) only Single, two, three phase, with or without neutral, TRMS measurements RS485 serial port, compatible with software for MK 22 Housing: Flush mount 96x96mm/3.78x3.78 egree of protection: IP54 on front; IP20 at terminals. suvision and energy management software See Section 27. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E , IEC/E , IEC/E , U508, CS C22.2 n Software and accessories pages -25 and 26 imensions page -30 Wiring diagrams page -35 page -45

24 igital measuring instruments Modular E instruments single phase non expandable MK 80 MK 81 MK 80 R1 MK 81 R1 MK 82 MK 82 rder isplayed Relay Qty Wt code measurements output pkg n n Voltmeter. MK 80 1 voltage value MK 80 R1❷ 1 max voltage value 1 1 min voltage value mmeter. MK 81 1 current value MK 81 R1❷ 1 max current value 1 1 min current value Voltmeter or ammeter. MK 82❶ 1 voltage or current value 1 maximum voltage or current value 1 minimum voltage or current value Frequency meter. MK 83 1 frequency value MK 83 R1❷ 1 max frequency value min frequency value Cosphi meter. MK 84 1 cosphi value MK 84 R1❷ 1 power factor value ❶ The MK82 can oate as a voltmeter or ammeter. It is duly equipped with two front plates (V and ) which must be fitted by the user depending on which instrument is required and on the wiring scheme used. ❷ Relay output with control and protection functions. The MK 8... instruments are available with modular housing, 3 module size. Measurements are True RMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC ating frequency: 50-60Hz True RMS measurements Max and Min measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 version only Modular I housing, 3 modules Terminals: 4mm 2 egree of protection: IP40 on front; IP20 on terminals. MK 80 - MK 80 R1 Voltage measurement range: VC ating frequency range: 45-65Hz Programmable VT ratio: ccuracy: ±0.25% f.s. ±1 digit MK 81 - MK 81 R1 Current measurement range: ating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 82 Voltage measurement range: VC Current measurement range: ating frequency range: 45-65Hz Programmable VT ratio: Programmable CT ratio: FF/5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit ccuracy: Current ±0.5% f.s. ±1 digit MK 83 - MK 83 R1 Measurement input: VC Frequency measurement range: 50-60Hz ±10% Measurement accuracy: ±1 digit ccuracy: ±1 digit MK 84 - MK 84 R1 Cosphi measurement error: ±0.5 ±1 digit Cosphi measurement in 4 quadrants ccuracy: ±1 ±1 digit MK 83 MK 83 R1 Control and protection functions MK 80 R1 Voltage loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% Time delay for max-min voltage or voltage loss ❸: seconds. MK 81 R1 Current loss: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% Time delay for max-min current or current loss ❸: seconds. MK 84 MK 84 R1 MK 83 R1 Maximum frequency: FF/ % Minimum frequency: FF/90-99% Time delay for min-max frequency ❸: seconds. MK 84 R1 Minimum-maximum cos thresholds in 4 quadrants Minimum-maximum PF thresholds in 4 quadrants elay time for max or min threshold ❸: 1-9,000 seconds. Certifications and compliance Certifications obtained: EC. Compliant with standards: IEC/E , IEC/E , IEC/E ❸ Independent adjustable delays. imensions page -31 Wiring diagrams page -35 page -42 and 43 -

25 igital measuring instruments Modular E instruments three phase non expandable MK 70 MK 71 MK 75 MK 70 R1 MK 71 R1 MK 75 R1 rder isplayed Relay Qty Wt code measurements output pkg n n Voltmeter. MK 70 3 phase voltage values MK 70 R1❷ 3 phase to phase voltage values max phase voltage values 3 max phase to phase voltage values 3 min phase voltage values 3 min phase to phase voltage values mmeter. MK 71 3 phase current values MK 71 R1❷ 3 max phase current values min phase current values Combined voltmeter, ammeter and wattmeter. MK 75 3 phase voltage values MK 75 R1❶❷ 3 phase to phase voltage values phase current values 4 active power values, phase and total 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 max active power, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 min active power, phase and total ❶ Connection also to single phase. ❷ Relay output with control and protection functions. The MK 7... instruments are available with modular housing, 3 module size. Measurements are True RMS values and provide for reliable oation even in the presence of harmonics. ational characteristics uxiliary supply voltage: VC ating frequency: 50-60Hz True RMS measurements Max and Min measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 version only Modular I housing, 3 module Terminals: 4mm 2 egree of protection: IP40 on front; IP20 on terminals. MK 70 - MK 70 R1 Voltage measurement range: VC ating frequency range: 45-65Hz Programmable VT ratio: ccuracy: ±0.25% f.s. ±1 digit MK 71 - MK 71 R1 Current measurement range: ating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 75 - MK 75 R1 Voltage measurement range: VC Current measurement range: Frequency measure range: 45-65Hz Programmable VT ratio: Programmable CT ratio: 5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit ccuracy: Current ±0.5% f.s. ±1 digit Control and protection functions MK 70 R1 Phase loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Maximum frequency: FF/ % Minimum frequency: FF/90-99% Time delay for max-min voltage, phase loss, asymmetry and min-max frequency ❸: seconds. MK 71 R1 Current loss: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% symmetry: FF/2-20% Time delay for max-min current or current loss and asymmetry ❸: seconds. MK 75 R1 Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/ % Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Current loss: FF/2-100% Maximum current: FF/ % Maximum current instantaneous tripping: FF/ % Minimum current: FF/5-98% symmetry: FF/2-20% Power Rated power: 1-10,000 Maximum power: FF/ % Maximum power instantaneous tripping: FF/ % Minimum power: FF/10-99% Frequency Maximum frequency: FF/ % Minimum frequency: FF/90-99% Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power ❸: seconds. Certifications and compliance Certifications obtained: EC. Compliant with standards: IEC/E , IEC/E , IEC/E ❸ Independent adjustable delays. -24 imensions page -31 Wiring diagrams page -35 page -44

26 ccessories for measuring instruments Communication devices CX 01 CX 02 CX 03 rder code escription Qty Wt pkg CX 01 USB/optical dongle with PC VT Electric product connecting cable, for programming, data download, diagnostics and firmware upgrade CX 02 Wi-Fi dongle for PC VT Electric product programming, data download, diagnostics and cloning CX 03 GSM/GPRS penta-band antenna (850/900/1800/1900/2100Mhz) for EXP1015 expansion module Communication devices for connection of VT Electric products to sonal computers, smartphones and tablets. CX 01 The USB/optical dongle, complete with cable, allows the connection of products compatible with PCs without having to disconnect the power supply from the electric panel. The PC identifies the connection as a standard USB. CX 02 By Wi-Fi connection, compatible VT Electric products can be viewed on PCs, smartphones and tablets with no need for cabling. CX 03 ntenna compatible with the major part of worldwide mobile networks thanks to the available frequencies at 850/900/1800/1900/2100MHz. egree of protection: IP67. Fixing by Ø10mm drilling. Cable length: 2.5mm For dimensions, wiring schemes and technical characteristics, refer to technical instructions in the ownloads section at: Protection covers rder code escription Qty Wt pkg P 96X48 Front protection cover, IEC IP for MK 0/ P 96X96 Front protection cover, IEC IP for MK 2... When a higher front IP protection degree is needed, the covers can be installed on the corresponding devices and also provide a sealing feature. 31 P96x96 ccessories EXP80 00 rder code escription Qty Wt pkg EXP80 00 Plastic insert for customising label fixing for MG 600/610 EXM80 04 Set of sealable terminal covers for MG 100/101/110/200/210/300-25

27 ccessories for measuring instruments Converter rder code escription Qty Wt pkg. EXC C 01 4 PX1 Connecting cables rder code escription Qty Wt pkg. 51 C4 MG M3 KIT... EXC C 01 RS485/Ethernet 12 48VC converter, including I rail fixing kit 4 PX1 RS2/RS485 galvanically isolated converter supply VC (or VC). Repeater for bus extension RS485 Gateway rder code escription Qty Wt pkg EXC M3G 01 EXC M3G 01 RS485/3G modem, VC/9.5 35VC, including antenna and programming cable, length 2.5m 51 C2 For PC multimeter RS2 port, 1.8m long 51 C4 For PC 4 PX converter drive, 1.8m long 51 C5 For analog modem multimeter RS2 port, 1.8m long 51 C9 For 4PX 1 converter drive analog modem, 1.8m long Current clamp kits for MG M3. portable devices MG M3 KIT01 Composed by 3 current clamps /1 and 4 alligator clip cables for voltage measurements MG M3 KIT02 Composed by 1 current clamps /1 and 1 alligator clip cable for voltage measurements. For MGM3900, if measuring inputs for neutral-earth/ground and neutral current are used too EXC C 01 CVERTER The EXC C 01 converter allows Slave devices connected on an RS485 network to interface with a Master featuring Ethernet port: kit comprising converter and I rail mounting accessory; programming via web interface; power supply not included. 4 PX1 CVERTER (RS2-RS485) It can interface Slave devices connected in an RS485 bus with a Master equipped with RS2 interface port. When configured appropriately, it can also be used as RS485 repeater whenever the devices connected to the bus are many or the maximum distance among the bus devices is longer than the allowed. EXC M3G 01 GTEWY The EXC M3G 01 gateway allows Slave devices connected on an RS485 network to interface with a Master via 3G network: TCP server connection via 3G or 2G network; Transparent oating mode: the data is transferred from 3G side to serial side and vice versa without protocol conversion; Parameters that can be set: TCP server remote port and IP, network oator P (with username and password), SIM card PI (with enablement), connection timeout, serial parameters (baud rate from 1200bps to bps, stop bit, number of characters, parity); RJ45 port for parameter programming and diagnosis with a simple software application. Compatible with major worldwide mobile phone networks, thanks to the use of 850/900/1800/1900/2100MHz frequencies. Protection rating IP67. Fixing hole Ø10mm. Cable length 2.5m. CECTIG CBES 51 C To connect energy meters and/or multimeters with: Personal computers Modems Bus converters. Electrical safety for MG M3 KIT... (IEC/E and IEC/E ) CURRET CMPS 600V category III 300V category IV. VTGE MESURIG CBES 1000V category III. Reference standards Compliant with standards: IEC/E , IEC/E , IEC/E For dimensions, wiring schemes and technical characteristics, refer to technical instructions in ownloads at -26

28 Current transformers Solid-core M0T... M2T... M3T... M35T... M4T... rder code Primary Burden Qty Weight current Ipn cl. 0.5 cl. 1 pkg. /5 [] [V] [V] For Ø22mm/0.87 cable. M0T M0T M0T M0T M0T For Ømm/0.90 cable. For 30x10mm/1.18x0.39, 25x12.5mm/0.98x0.49, 20x15mm/0.79x0.59 busbars. M2T M2T M2T M2T M2T M2T For Ø30mm/1.18 cable. For 40x10mm1.57x0.39, 30x20mm/1.18x0.79, 25x25mm/0.98x0.98 busbars. M3T M3T M3T M3T M3T M3T M3T For Ø66mm/2.60 cable. For 80x12,5mm/3.15 x0.49, 60x30mm/2.36x1.18, 50x50mm/1.97x1.97 busbars. M35T M35T M35T For Ø86mm/3.38 cable. For 100x30mm/3.94x1.18, 80x50mm/3.15x1,97, 70x60mm/2.75x2.36 busbars. M4T M4T M4T M4T M4T M4T M4T M4T M4T The current transformers (CTs) in the M series are installed in an electrical system to reduce the line current to a secondary value of 5 compatible with the ammeter inputs of the digital multimeters or protection relays. M... are instrument transformers in class 1/0.5 without a primary winding and are normally used for high primary current values starting from 50. The number of loops of the primary cable does not modify the accuracy but converts the primary current value proportional to secondary current. 300/5 300/5 300/5 S1 K S1 K S1 K J-29 P1-K J-29 P1-K J-29 P1-K S2 300:n/5 300:1/5=300/5 S2 300:n/5 300:2/5=150/5 S2 300:n/5 300:3/5=100/5 n =1 300 / 5 standard 1 loop = 300 / 5 n =2 300 / 5 2 loops = 150 / 5 n =3 300 / 5 3 loops = 100 / 5 ational characteristics ating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Insulation (dry type): Class E Terminals: Faston for M2T and M3T types Screw for M0T, M4T and M35T types Sealable terminal covers for M4T and M35T types Fixing on 35mm I rail (IEC/E 60715) or by screws (fixing elements standard supplied with the product) IEC degree of protection: IP30 mbient conditions ating temature: C Storage temature: C. Relative humidity, non condensing: 90%. Reference standards Compliant with standards: IEC/E , IEC/E imensions page

29 Current transformers ccuracy solid-core M1TP... M3TP... M5TP... Versions with Italian UTF certificates on request. rder code Primary Burden Qty Weight current Ipn cl. 0.5s cl. 0.5 pkg. /5 [] [V] [V] For Ø28mm/1.10 ❶ cable. For 30x10mm/1.18x0.39, 25x12.5mm/0.98x0.49, 20x20mm/0.79x0.79 busbar. M1TP M1TP ,5 2, M1TP M1TP M1TP M1TP M1TP M1TP 0400❷ M1TP 0500❷ For Ø52mm2.04 ❶ cable. For 60x20mm/2.36x0.79, 50x25mm/1.97x0.98 busbar. M3TP M3TP M3TP M3TP For Ø66mm/2.60 ❶ cable. For 100x20mm/3.94x0.79, 80x45mm/3.15x1.77 busbar. M5TP M5TP M5TP M5TP M5TP M5TP ❶ Consult Customer Service to inquiry about versions with Italian UTF certificates. ❷ For Ø33mm cable. For 40x10mm, 30x20mm, 25x25mm busbar. The M...TP type accuracy current transformers (CTs) are installed in an electrical system to reduce the line current to a secondary value of 5 compatible with the ammeter inputs of the digital multimeters or protection relays. M...TP are accuracy current transformers in class 0.5s without a primary winding and are normally used for high primary current values starting from 60. The number of loops of the primary cable does not modify the accuracy but converts the primary current value proportional to secondary current. 300/5 300:n/5 300:1/5=300/5 300/5 300:n/5 300:3/5=100/5 300/5 n=1 300 / 5 standard 1 loop = 300 / 5 n=2 300 / 5 2 loops = 150 / 5 n=3 300 / 5 3 loops = 100 / 5 300:n/5 300:3/5=100/5 ational characteristics ating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Insulation (dry type): Class E Screw terminals Sealable terminal covers Fixing on 35mm I rail (IEC/E 60715) or by screws (fixing elements standard supplied with the product) IEC degree of protection: IP30 mbient conditions ating temature: C Storage temature: C. Relative humidity, non condensing: 90%. Reference standards Compliant with standards: IEC/E , IEC/E imensions page -31

30 Current transformers Compact prewired split-core M1TM... rder code Primary Burden Qty Weight current Ipn cl. 0.5 cl. 1 pkg. /5 [] [V] [V] 24x24mm/0.94x0.94 hole. Cable supplied as standard, length 1m. M1TM M1TM M1TM M1TM x38mm/1.42x1.50 hole. Cable supplied as standard, length 1m. M2TM M2TM M2TM M2TM The M...TM type current transformers (CTs) are installed in an electrical system to reduce the line current to a secondary value of 5 compatible with the ammeter inputs of the digital multimeters or protection relays. M...TM are instrument transformers in class 1 without a primary winding and are normally used for high primary current values starting from 100. ational characteristics ating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Cable supplied as standard, length 1m. Insulation (dry type): Class E mbient conditions: ating temature: C Storage temature: C Relative humidity, non condensing: 90%. M2TM... Reference standards Compliant with standards: IEC/E , IEC/E Split-core M1T... M2T... M3T... rder code Primary Burden Qty Weight current Ipn cl. 0.5 cl. 1 pkg. /5 [] [V] [V] 50x80mm/1.97x3.15 hole. M1T M1T M1T M1T M1T M1T M1T x80mm/3.15x3.15 hole. M2T M2T M2T M2T M2T M2T M2T x120mm/3.15x4.72 hole. M3T M3T M3T M3T M3T M3T x160mm/3.15x6.30 hole. M4T M4T M4T M4T The M...T type current transformers (CTs) are installed in an electrical system to reduce the line current to a secondary value of 5 compatible with the ammeter inputs of the digital multimeters or protection relays. M...T are instrument transformers in class 0.5/1 without a primary winding and are normally used for high primary current values starting from 250. ational characteristics ating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Insulation (dry type): Class E Screw terminals Sealable terminal covers Screw fixing (fixing elements standard supplied with the product) IEC degree of protection: IP30 mbient conditions ating temature: C Storage temature: C. Relative humidity, non condensing: 90%. Reference standards Compliant with standards: IEC/E , IEC/E M4T... imensions page

31 imensions [mm (in)] EERGY S Mechanical meter ME M igital meter ME ME (0.69") 59.9 (2.35") 43.8 (1.72") igital meter ME 115 T1 - ME 120 T1... ME ME (1.41") 5 (0.20") 58 (2.28") 43.7 (1.72") igital meter ME 300 T ME 300 F - ME 310 F... - ME 310 T ME ME ME 305 T2 ata concentrator ME C - ME C PV (2.82") 5 (0.20") 58 (2.28") 43.7 (1.72") 5 (0.20") MUTIS MG MG MG MG MG MG 300 Expansion modules EXM (2.82") 5 (0.20") 63 (2.48") 43.8 (1.72") 42.7 (1.68") 11 (0.43") 35.8 (1.41") 63 (2.48") 43.8 (1.72") (4.15") 90 (3.54") 45 (1.77") 63.5 (2.50") 93.4 (3.68") 95 (3.74") 90 (3.54") 45 (1.77") 63.5 (2.50") 36.4 (1.43") MG MG (3.78") 65 (2.56") 55 (2.16") 8.5 (0.33") MG MG MG with expansion modules EXP (3.78") 26.3 (1.03") 53.2 (2.09") 19 (0.75") 92 (3.62") 61.5 (2.42") EXP FUSH-MUT IG ISTRUMETS Instruments MK MK (3.78") 24 (0.94") 81 (3.19") 9 (0.35") 92 (3.62") 44 (1.73") 48 (1.89") 45 (1.77") FUSH-MUT MUTIS MK (3.78") 14 (0.55") 62 (2.44") 6 (0.24") 92 (3.62") 90 (3.54") 96 (3.78") 92 (3.62") 99.5 (3.92") 64.5 (2.54") 96 (3.78") 92 (3.62") EXP Transducer MG 900T with expansion modules EXP (0.79") 115 (4.53") 96 (3.78") 5 (0.20") 28.8 (1.13") 43.5 (1.71 ) 37.3 (1.47 ) MG 900R remote display 96 (3.78") 24 (0.94") 19 (0.75") Cutout 92 (3.62") 110 (4.33") (3.99") 64.5 (2.54 ) 96.3 (3.79 ) 90.8 (3.57") 96 (3.78") 92 (3.62") 85 (3.35") 45 (1.77") 98.3 (3.87") (4.12") 45 (1.77") 90 (3.54") 98.3 (3.87") (4.12") 45 (1.77") 90 (3.54") Ø4.2 (0.16") Ø4.2 (0.16") Cutout 54 (2.12") 91.6 (3.61") 91.7 (3.61") EXP Cutout Cutout -30

32 imensions [mm (in)] IGIT IG ISTRUMETS MK MK (2.11") 5 (0.20") 58.1 (2.29") 43.8 (1.72") 90 (3.54") 99 (3.90") (4.15") 45 (1.77") Ø4.2 (0.16") CURRET TRSFRMERS Solid core M0T (1.26 ) M2T (2.05") 9.5 (0.37") 46.5 (1.83") M3T (2.79") 9.5 (0.37") 62.5 (2.46") Ø22 (0.87 ) 44 (1.73 ) M35T (2.60 ) 30 (1.18 ) 28 (1.10") Ø (0.90") 10 (0.39") (0.79") (0.79") 30 (1.18") 12.5 (0.49") 15 (0.59") 65.5 (2.58") 27.5 (1.08") 56.5 (2.22") 36.5 (1.44") M4T... Ø30 (1.18") 25 (0.98") 30 (1.18") 40 (1.57") 10 (0.39") 20 (0.79") 104 (4.09") 40 (1.57") 81.5 (3.19") 44.5 (1.75") 72.5 (2.85") 53 (2.08") Ø66 (2.60 ) 12.5 (0.49 ) 31.5 (1.24 ) 51.5 (2.03 ) 61.5 (2.42 ) (4.98 ) Ø86 (3.38") 31 (1.22") 51 (2.01") 61 (2.40") 71 (2.79") 81 (3.19") 155 (6.10") 31.5 (1.24 ) 51.5 (2.03 ) 61.5 (2.42 ) 81.5 (3.21 ) 105 (4.13 ) M1TP M1TP (0.79 ) 41.5 (1.63 ) M1TP M1TP (2.91") 51 (2.01") 101 (3.98") 121 (4.76") 140 (5.51") 60 (2.36 ) 45 (1.77 ) 11.5 (0.45 ) 11 (0.43 ) 41.5 (1.63 ) Ø28 (1.10 ) 16 (0.63 ) 16.5 (0.65 ) 21.5 (0.85 ) 26 (1.02 ) 31.5 (1.24 ) 98.5 (3.88 ) Ø33 (1.30 ) 21 (0.83 ) 26.5 (1.04 ) 31.5 (1.24 ) 41.5 (1.63 ) 98.5 (3.88 ) 55 (2.16 ) (0.45 ) (0.65 ) (0.85 ) (1.02 ) 31.5 (1.24 ) 74.5 (2.93 ) M3TP (0.43 ) (0.83 ) (1.04 ) (1.24 ) 41.5 (1.63 ) 74.5 (2.93 ) 65 (2.56 ) 45 (1.77 ) M5TP (1.57 ) (0.79 ) 6.4 (0.25 ) 15.5 (0.61 ) 65 (2.56 ) 45 (1.77 ) Ø52 (2.05 ) 21 (0.83 ) 52 (2.05 ) 61 (2.40 ) 127 (5.00 ) Ø85.5 (3.37 ) 22 (0.87 ) 45 (1.77 ) 81 (3.19 ) 101 (3.98 ) (6.44 ) 21 (0.83 ) 25 (0.98 ) 61 (2.40 ) 101 (3.98 ) 16 (0.63 ) 20 (0.79 ) 45 (1.77 ) 54.5 (2.14 ) 6.4 (0.25 ) 15.5 (0.61 ) 55 (2.16 ) 22 (0.87 ) 45 (1.77 ) 62 (2.44 ) 81 (3.19 ) 101 (3.98 ) 144 (5.67 ) 16 (0.63 ) 20 (0.79 ) 45 (1.77 ) 80.5 (3.17 ) 6.4 (0.25 ) 15.5 (0.61 ) 55 (2.16 ) -31

33 imensions [mm (in)] Compact prewired split-core M1TM (1.10") M2TM (1.30") Split-core M1T (4.49") 50 (1.97") S2 P2 80 (3.15") 144 (5.67") 25 (0.98") 43.5 (1.71") 66.5 (2.62") (0.90") 37 (1.46") 49.5 (1.95") 86 (3.38") 36.5 (1.44") 24 (0.94") 45.5 (1.79") 34.5 (1.36") 37 (1.46") 57.5 (2.26") 42 (1.65") M2T (5.59") 50 (1.97") M3T (5.59") 50 (1.97") S2 P2 S2 P2 80 (3.15") 144 (5.67") 120 (4.72") 184 (7.24") P2 32 (1.26") P2 32 (1.26") 52 (2.05") 78 (3.07") 32 (1.26") 80 (3.15") 109 (4.29") 32 (1.26") P2 32 (1.26") M4T (3.15") 109 (4.29") 32 (1.26") 184 (7.24") 68 (2.68") S2 P2 47 (1.85") 32 (1.26") 38 (1.50") 38 (1.50") 245 (9.64") 160 (6.30") 175 (6.89") 80 (3.15") 120 (4.72") 32 (1.26") 52 (2.05") -32

34 Wiring diagrams EERGY S Mechanical ME M100 0VC ME M100 T VC 640 pulses/kwh Vce max: 35V Imax: 20m igital ME 100 T ME 110 T1... ME 115 T1 - ME 120 T ME 130 ME Static Static B RS485 IE IE IE VC ❶ VC ME...120; VC ME...; 0V 50Hz ME... T1 MI. ME 300 T ME 300 F IE V (-) V (-) Tariff input VC T1 T2 + 1 Static 2 + Pulse output 30VC 50m ❶ 0V 50Hz (-), 400V 50Hz (-) ME... T2 MI / ME... F. ME 310 T ME 310 F V (-) V (-) 3 V1 V2 V3 V S1S2 S1 S2 S1 T1 T2 1+ Static I1 I2 I3 S Pulse output 30VC 50m ME 301 IE V (-) V (-) Tariff input VC T1 TR T2 RS485 B S ME ME 305 T2 Single phase Two phase Three phase with or without neutral CT2 CT2 CT VC VC VC VC VC VC 1 2 UX SUPPY V1 V2 V3 V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET Three phase without neutral in R connection CT2 CT3 Pulse output 30VC 50m for ME 305 T2 Static VC VC VC VC RS485 for ME UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET TR B S RS485 ata concentrator ME C - ME C PV VC VC VC 110VC CM1 I1.1 I T1 T2 TR B SG ux Supply Tariff Input RS485 2 x 4 groups Insulated inputs CM2 I2.1 I2.2 CM3 I3.1 I3.2 CM4 I4.1 I4.2-33

35 Wiring diagrams MUTIS MG MG MG MG MG MG 300 Single phase Two phase Three phase with or without neutral CT2 CT2 CT VC VC VC VC VC VC 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET Three phase without neutral in R connection Balanced 3-phase connection with or without neutral CT2 CT S1 S VC VC VC VC VC VC 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET UX SUPPY V1 V2 V3 V VTGE S1 S2 I1 S1 S2 S1 S2 I2 I3 CURRET B RS485 MUTIS MG MG Two phase Single phase MG Single phase Two phase VC ❶ VC VC VC ❶ VC VC CT VC ❷ VC VC VC ❷ VC VC CT2 1 2 UX SUPPY V1 V2 V3 V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 UX SUPPY V1 V2 V3 V4V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET S1 S2 I4 1 2 V1 V2 V3 V4V S1 S2 S1 S2 S1 S2 I1 I2 I3 UX SUPPY VTGE CURRET S1 S2 I4 Three phase with or without neutral Three phase with or without neutral CT2 CT3 CT2 CT VC ❶ VC VC VC ❷ VC VC 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 V1 V2 V3 V4V S1 S2 S1 S2 S1 S2 I1 I2 I3 UX SUPPY VTGE CURRET S1 S2 I4 Three phase without neutral in R connection Three phase without neutral in R connection CT2 CT2 CT VC ❶ VC VC VC ❷ VC VC VC ❷ VC VC 1 2 UX SUPPY V1 V2 V3V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET 1 2 V1 V2 V3 V4V S1 S2 S1 S2 S1 S2 I1 I2 I3 UX SUPPY VTGE CURRET S1 S2 I4 1 2 UX SUPPY V1 V2 V3 V4V VTGE S1 S2 S1 S2 S1 S2 I1 I2 I3 CURRET S1 S2 I VC ❶ VC VC 1 2 UX SUPPY ❶ For MG only. CT3 V1 V2 V3V S1 S2 S1 S2 S1 S2 I1 I2 I3 VTGE CURRET Two phase with neutral. Measurement of neutral current and neutral-earth voltage VC ❷ VC VC CT2 1 2 V1 V2 V3 V4V S1 S2 S1 S2 S1 S2 I1 I2 I3 UX SUPPY VTGE CURRET CT4 S1 S2 I4 Three phase with neutral. Measurement of neutral current and neutral-earth voltage VC ❷ VC VC CT2 CT3 1 2 V1 V2 V3 V4V S1 S2 S1 S2 S1 S2 I1 I2 I3 UX SUPPY VTGE CURRET CT4 S1 S2 I4 ❷ For MG only. -34

36 Wiring diagrams IG ISTRUMETS MK 00 - MK 00 R1 MK 01 - MK 01 R1 MK 02 Voltmeter / / / mmeter / V~ 5~ 600V~ 5~ VC For MK 00 R VC For MK 01 R VC VC MK 03 - MK 03 R1 / MK 04 - MK 04 R1 Single phase Three phase 600V~ 45/65Hz 600V~ 5~ VC For MK 03 R VC For MK 04 R1 MK 10 - MK 10 R1 MK 11 - MK 11 R1 MK 15 - MK 15 R1 MK 16 - MK 16 R V~ 5~ 600V~ 5~ 600V~ 5~ VC For MK 10 R VC For MK 11 R VC For MK 15 R VC For MK 16 R1 MK 80 - MK 80 R1 MK 81 - MK 81 R1 MK 82 Voltmeter / 600V~ / / S1 5~ S2 / 600V~ / S1 S2 mmeter / / S1 S2 5~ MK 70 - MK 70 R V~ / VC 600V~ 45/65Hz For MK 80 R1 MK 83 - MK 83 R1 / VC For MK 81 R VC MK 84 - MK 84 R1 Single phase / 600V~ 5~ S1 S VC Three phase V~ 5~ VC I1 I2 I3 CM 5~ For MK 70 R1 MK 71 - MK 71 R VC For MK 83 R1 FUSH-MUT MUTIS MK2... Single phase MK VC MK VC Two phase 1 2 MK VC MK VC CT VC VC For MK 84 R1 For MK 84 R1 Three phase with or without neutral 1 CT2 2 CT3 3 MK VC MK VC VC V~ For MK 71 R1 MK 75 - MK 75 R1 I1 I2 I3 CM 5~ I1 I2 I3 C UX SUPPY VTGE CURRET I1 I2 I3 C UX SUPPY VTGE CURRET I1 I2 I3 C UX SUPPY VTGE CURRET VC For MK 75 R1 Three phase without neutral in R connection CT CT3 MK VC MK VC MK VC MK VC I1 I2 I3 C I1 I2 I3 C UX SUPPY VTGE CURRET UX SUPPY VTGE CURRET -35

Switches Unlimited Contact: Phone: * Fax:

Switches Unlimited Contact: Phone: * Fax: Page -10 EERGY S Single phase, three phase with neutral, three phase with or without neutral irect connection or by current transformers MI certified versions Expandable versions. Page -15 T CCETRTRS Energy

More information

METERING INSTRUMENTS AND CURRENT TRANSFORMERS 23

METERING INSTRUMENTS AND CURRENT TRANSFORMERS 23 IG ISTRUMETS CURRET TRSFRMERS igital voltmeters, ammeters, wattmeters, frequency meters and cosphi meters igital multimeters and power analyzers, expandable, with graphic C Connection to single, two, three

More information

Metering instruments and current transformers

Metering instruments and current transformers Single and three-phase energy meters MI certified versions with UTF certificates igital voltmeters, ammeters, wattmeters, frequency meters and cos meters igital multimeters and power analyzers, expandable,

More information

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

METERING INSTRUMENTS AND CURRENT TRANSFORMERS Energy Meters p16-1 Data Concentrators p16-3 Digital Measuring Instruments p16-4 Expansion Modules and Accessories p16-15 Current Transformers p16-19 Software and Applications p16-22 Systems Management

More information

DIGITAL LCD MULTIMETERS AND POWER ANALYZERS Graphic LCD or touch screen Remote display Expandable versions.

DIGITAL LCD MULTIMETERS AND POWER ANALYZERS Graphic LCD or touch screen Remote display Expandable versions. Page -8 EERGY S Single phase, three phase with neutral, three phase with or without neutral irect connection or by current transformers MI certified versions ata concentrator. IGIT C MUTIS PWER YZERS Graphic

More information

DIGITAL METERING INSTRUMENTS DMG SERIES

DIGITAL METERING INSTRUMENTS DMG SERIES DIGITAL METERING INSTRUMENTS DMG SERIES DMG series Digital metering instruments For the control of energy distribution system detecting when problems occur that could put the quality and availability of

More information

Digital metering instruments and current transformers

Digital metering instruments and current transformers Digital metering instruments and current transformers Digital metering instruments, DMK series: 96x48mm Flush-mount version Modular version Single - phase Single-function Voltmeter mmeter Voltmeter or

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

Expansion modules and accessories

Expansion modules and accessories Digital inputs and outputs Analog inputs and outputs Communication interface Data storage with clock-calendar Communication devices to connect LOVATO Electric products to sonal computers, smartphones and

More information

Digital multimeters DMG

Digital multimeters DMG Digital multimeters DMG 600-610 ENERGY AND AUTOMATION POWER OF ENERGY SAVING Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow

More information

E N E R G Y M E T E R S

E N E R G Y M E T E R S ENERGY METERS For efficient management of energy consumption In a global scenario in which energy must be monitored and managed efficiently, LOVATO Electric presents its updated series of energy meters

More information

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES 2 power sources automatic transfer switch controllers The automatic transfer switch controllers ATL 600 - ATL 610 - ATL 800 can supervise and manage the

More information

Page Page Page ACCESSORIES Communication devices Remote display unit Protective covers Converters Gateway Connecting cables.

Page Page Page ACCESSORIES Communication devices Remote display unit Protective covers Converters Gateway Connecting cables. Page -2 EXP SERIES EXPANSION MODULES For flush-mount products Digital Inputs and Outputs Analog Inputs and Outputs Inputs for PT100 sensors Communication modules (RS232, RS485, Ethernet, etc.) GSM/GPRS

More information

Page measurement up to 15th order Front optical USB and Wi-Fi communication port for PC, smartphone and tablet connection

Page measurement up to 15th order Front optical USB and Wi-Fi communication port for PC, smartphone and tablet connection DCRM SERIES Modular housing 2 steps Settings by front potentiometers 3 LED indications. Page -8 Page -9 DCRL SERIES (EXPANDABLE) Flush-mount housing: DCRL 3 - DCRL 5 (96x96mm/3.78x3.78 ) DCRL 8 (144x144mm/5.67x5.67

More information

Switches Unlimited Contact: Phone: * Fax:

Switches Unlimited Contact: Phone: * Fax: Page -2 EXP SERIES EXPANSION MODULES Digital inputs and outputs Analog inputs and outputs Inputs for PT100 sensors Communication modules (RS232, RS485, Ethernet, etc.) GSM/GPRS modem Data storage with

More information

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration

More information

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9 7% Metering E Modular energy (kwh) meters Lovato E-1 Socomec E-7 Modular multi-meters Lovato E-2 Socomec E-8 Panel mount network analysers Lovato E-3 4 Socomec E-8 9 Digital panelmeters Lovato E-5 6 Digiware

More information

Page Backlight graphic display, 128x80 pixels. Optic interface port for programming, data download and diagnostics

Page Backlight graphic display, 128x80 pixels. Optic interface port for programming, data download and diagnostics Page -6 Page -7 DCRM SERIES 2 steps in modular housing Settings by front adjustment potentiometers 3 LED indications. DCRL SERIES (EXPANDABLE 3 or 5 steps in 96x96mm housing expandable up to 7 steps maximum

More information

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1 Engine Protection Controllers p18-1 18 Stand Alone en-set Controllers p18-2 Automatic Mains Failure en-set Controllers p18-3 Automatic Transfer Switch Controllers p18-6 Accessories p18-10 Software p18-11

More information

100% electricity. Power factor correction components

100% electricity. Power factor correction components 100% ity Power factor correction components Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration in 144x144mm housing Capacitor

More information

AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES 23

AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES 23 AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES Microprocessor supervision and control Accurate TRMS measurement circuit Automatic intelligent adjustment system Versions with 2, 3, 5, 7, 8, 12,

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

AND COMMUNICATION MODULES

AND COMMUNICATION MODULES Page -4 Page -4 MICRO PCs 10 Inputs/Outputs (RD10...) 12 Inputs/Outputs (RD12...) Inputs/Outputs (RD...) 12VDC,, or 100-240VAC power supply Relay or transistor outputs. EXPANSION AND COMMUNICATION MODUES

More information

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9 Metering E Modular energy (kwh) meters Lovato E-1 Socomec E-7 Modular multi-meters Lovato E-2 Socomec E-8 Panel mount network analysers Lovato E-3 4 Socomec E-8 9 Digital panelmeters Lovato E-5 6 Digiware

More information

SOFT STARTERS PLANET -LOGIC

SOFT STARTERS PLANET -LOGIC SOFT STARTERS PAGE -2 ADXM...BP Rated starter current Ie 6 to 45A ratings Rated motor power 2.2 to 22kW at 400VAC Integrated by-pass relay Total protection against over-temperature Acceleration and deceleration

More information

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight

More information

ENERGY AND AUTOMATION

ENERGY AND AUTOMATION ENERGY AUTOMATION SINCE 1922 The first LOVATO Electric headquarters was established in Bergamo, Italy, in 1922: the starting point of a great industrial adventure. THE STORY OF A FAMILY, THE SPIRIT OF

More information

ENERGY AND AUTOMATION

ENERGY AND AUTOMATION ENERGY AUTOMATION SINCE 1922 The first LOVATO Electric headquarters was established in Bergamo, Italy, in 1922: the starting point of a great industrial adventure. THE STORY OF A FAMILY, THE SPIRIT OF

More information

ATS Automatic transfer switches Advanced version

ATS Automatic transfer switches Advanced version 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS

More information

PM800 series. Applications

PM800 series. Applications Functions and characteristics PE86134 The PowerLogic meters offers many high-performance capabilities needed to meter and monitor an electrical installation in a compact 96 x 96 mm unit. All models include

More information

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL SOFT STARTERS ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL Simplicity The ADXL series of soft starters is equipped with a backlit LCD icon display and NFC connectivity for quick and easy configuration,

More information

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed.

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed. PQM4000 and PQM4000 PQM4000RGW Class A DIN 192x144 power quality analyzer for CTs Class A certified in compliance with IEC/EN 61000-4-30:2015 Ed. 3 APPLICATIONS PQM4000 is connected to networks and facilities

More information

ENGINE AND GENERATOR CONTROLLERS

ENGINE AND GENERATOR CONTROLLERS ENINE AND ENERATOR CONTROLLERS ENINE PROTECTION CONTROLLERS Starting with or without power key switch Programmable inputs and outputs Front LED indicators for engine alarm conditions and diagnostics. STAND

More information

ABB NETWORK ANALYSER M2M. Quick set-up guide

ABB NETWORK ANALYSER M2M. Quick set-up guide NETWORK NLYSER Quick set-up guide The purpose of this guide is to offer the quickest way to set up and start to use the device. Consult the Instruction manual with the CD-Rom included in the packaging

More information

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port Viale Borri 231, 21100 Varese - Italy Pulse concentrator, 12 inputs, Contents Pages 1. Description - Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation - Connection... 2 5. General characteristics...

More information

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter TOU SMART ENERGY METER SATEC is a Smart DIN Rail TOU Energy Meter. It is based on SATEC s best seller PM130 PLUS with an off-theshelf LCD display (similar to the BFM136 display). The provides the full

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

PQM4000 and PQM4000RGW

PQM4000 and PQM4000RGW PQM4000 and PQM4000RGW Class A DIN 192x144 power quality analyzer Class A certified for CTs or current clamps (PQM4000) with Rogowski coils (PQM4000RGW) PQM4000 Class A DIN 192x144 power quality analyzer

More information

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement

More information

NEW AUTOMATIC P.F. CORRECTION BANKS. MULTImatic. Powerful, versatile and smarter thanks to the new RPC 8BGA Controller QUALITY MADE IN ITALY

NEW AUTOMATIC P.F. CORRECTION BANKS. MULTImatic. Powerful, versatile and smarter thanks to the new RPC 8BGA Controller QUALITY MADE IN ITALY 2013 NEW AUTOMATIC P.F. CORRECTION BANKS MULTImatic Powerful, versatile and smarter thanks to the new RPC 8BGA Controller QUALITY MADE IN ITALY NEW MULTImatic is even smarter and more performing. Thanks

More information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information Power and accuracy 0.2% or 0.5% class in power and active energy measurement Over 500 electric parameters display Both voltage and current harmonics spectrum graphics (to the 50 th ) Maximum and minimum

More information

Hot pluggable communication modules

Hot pluggable communication modules precision metering series in-built IEC 61850 support Best in class accuracy User friendly multilingual display Field con gurable for various installations Hot pluggable communication modules Prometer 100,

More information

Page ATL 610 Management of two power sources. AC and DC power supply. 6 programmable digital inputs. 7 programmable relay outputs

Page ATL 610 Management of two power sources. AC and DC power supply. 6 programmable digital inputs. 7 programmable relay outputs AT 600 Management of two power sources AC power supply 6 programmable digital inputs 7 programmable relay outputs. Page -6 Page -6 AT 610 Management of two power sources AC and DC power supply 6 programmable

More information

AND COMMUNICATION MODULES

AND COMMUNICATION MODULES Page -4 Page -4 MICRO PCs 10 Inputs/Outputs (RD10...) 12 Inputs/Outputs (RD12...) Inputs/Outputs (RD...) 12VDC,, or power supply Relay or transistor outputs. EXPANSION AND COMMUNICATION MODUES 4 digital

More information

Automatic Power Factor Controllers Thyristor Modules p17-7

Automatic Power Factor Controllers Thyristor Modules p17-7 Automatic Power Factor Controllers Thyristor Modules p17-7 Power Factor Correction Capacitors p17-9 Harmonic Filter Reactors p17-10 EMI Filters for AC Drives p17-11 Reactors and Filters for AC Drives p17-13

More information

Engine and generator controllers

Engine and generator controllers Engine and generator controllers Page 8 Page 9 ENINE PROTECTION CONTROLLERS Starting with or without power key switch Programmable inputs and outputs Front LED indicators for engine alarm conditions and

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Power Management System. Multifunction Measuring Instruments

Power Management System. Multifunction Measuring Instruments Power Management System Multifunction Measuring Instruments Power Management System /2 - System overview /2 - More information PAC3200 Multifunction Measuring Instruments /3 - Overview /4 - Benefits /5

More information

METERING INSTRUMENTS DIGITAL MULTIMETERS AND ENERGY METERS NETWORK ANALYZERS DATA CONCENTRATOR COMMUNICATION DEVICES

METERING INSTRUMENTS DIGITAL MULTIMETERS AND ENERGY METERS NETWORK ANALYZERS DATA CONCENTRATOR COMMUNICATION DEVICES A P R I L 2016 METERING INSTRUMENTS DIGITAL MULTIMETERS AND ENERGY METERS NETWORK ANALYZERS DATA CONCENTRATOR COMMUNICATION DEVICES ENERGY METERS DIRECT CONNECTION OR BY CURRENT TRANSFORMERS MID CERTIFIED

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Electrical multifunction analysers

Electrical multifunction analysers GENERAL Electrical multifunction analysers On top of the previously mentioned instruments, Contrel Elettronica offers also a complete range of electrical parameters analysers EMA series, for monitoring,

More information

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s CARLO GAVAZZI A u t o m a t i o n C o m p o n e n t s VMU-C/Y, Em 2 The VMU-C EM is the ideal web-server based solution for monitoring small to medium size installations. With its integrated M2M functionalities

More information

EngyVolt RV12 and RV15

EngyVolt RV12 and RV15 Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

EC 600 Electronic Volume Corrector

EC 600 Electronic Volume Corrector EC 600 Electronic Volume Corrector A recognized leader in natural gas measurement and control, RMG has enhanced its product portfolio with the EC 600 a certified and best-in-class electronic volume corrector.

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter 3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MW/MVAR Transducer Specifications

MW/MVAR Transducer Specifications GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch AT series Set-up and remote control software AT SW Measurement viewing of 2 sources Data and event viewing and printout Set-up data programming Real time clock

More information

Electronic Submeter with Advanced WiFi Ethernet Capability

Electronic Submeter with Advanced WiFi Ethernet Capability SH RK 100S Electronic Submeter with Advanced WiFi Ethernet Capability AGGRESSIVE TECHNOLOGY W NEIndustry Leading Technology High Performance Metering Technology 0.2% Accuracy Class Revenue Certifiable

More information

DIRIS A-30 Multifunction power metering & monitoring device - PMD

DIRIS A-30 Multifunction power metering & monitoring device - PMD Single-circuit metering, measurement & analysis The solution for > Industry > Building > Infrastructures diris_986_a_us.psd Strong points Function The is a power metering and monitoring device that provides

More information

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS The IPM-500 Series s for DIN rail mounting cover the most different application requirements for single-phase and threephase systems. Available

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

MI 2792A PowerQ4 Plus

MI 2792A PowerQ4 Plus Ws E Plu N PowerQ MI 2792 PowerQ Plus Best Buy Class Featured Power Qualitynalyser! Now with GPS Module in the set! The MI 2792 PowerQ Plus is top of the range power quality analyser. With it s current

More information

Multifuncion Measuring Device 96x96 mm, connection via CT

Multifuncion Measuring Device 96x96 mm, connection via CT Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...

More information

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B) Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B01-03-16B) 2 Safety precautions Follow the warnings described in this manual with the symbols shown below. DANgeR Warns of a risk, which could

More information

THE NEXT TRANSDUCER GENERATION

THE NEXT TRANSDUCER GENERATION THE NEXT TRANSDUCER GENERATION ADJUSTABLE HIGH-ACCURACY HEAVY-CURRENT SENSORS SINEAX DM5S/DM5F Heavy-current sensor for grid monitoring. SINEAX DM5S and SINEAX DM5F are freeprogrammable universal measurement

More information

WM20. Power analyzer for three-phase systems. Benefits. Description

WM20. Power analyzer for three-phase systems. Benefits. Description WM20 Power analyzer for three-phase systems Description WM20 is a modular power analyzer for single-, two- and three-phase systems. It is made up of a maximum of three components: the main unit that displays

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser 4 Target Max. Demand (MD) Load Shed Controller Up to 64 loads may be shed to

More information

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter PM130 PLUS POWER METER The PM130 PLUS is a compact, multi-function, three-phase AC powermeter specially designed to meet the requirements of users ranging from electrical panel builders to substation operators.

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain

More information

Power Management System. Measuring Devices for Power Distribution

Power Management System. Measuring Devices for Power Distribution Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview

More information

CALEC energy master The benchmark in energy measurement

CALEC energy master The benchmark in energy measurement CALEC energy master The benchmark in energy measurement District heating and cooling: New tariff structures for optimum plant management Secure investment with long-term stability Type approval to EU/2004/22

More information

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application UMG 96RM UMG 96RM Universal measurement instrument The UMG 96RM is a very compact and powerful universal measurement device designed for use in low and medium voltage distribution systems. In addition

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O U niversal Measuring Device Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application

More information

Millenium 3 logic controllers

Millenium 3 logic controllers Millenium 3 logic controllers Type Part number Power supply Inputs Outputs With display Without display CD12 88970041 24 V c 8 digital (of which 4 are analogue) 4 x 8 A relays 88970042 24 V c 8 digital

More information

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication SPCOM - Network analyser Content.2 Description.3 Specom C - Technical data.4 Specom M - Technical data.5 Data communication.5 Converter RS 485/232.5 Specom L - xploitation software The SPCOM network analyser

More information

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System Energy Division Crompton Instruments Integra 1630 Low Profile Digital Metering System DIN Integra 1630 Series Multifunction Integra 1630 digital metering system provides high accuracy 0.2% measurement,

More information

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter IEC and ANSI Revenue Grade Accuracy Measurement Standard

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG www.oem.co.uk Contents Shunts Page 3-4 Digital Meters with Bargraph Page 5-6 Large Displays Page 6-7 Power Analyzers, Synchronizing Units Page 8 Recorders Page

More information

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics SIA-C Overcurrent and Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered Main characteristics The SIA-C is a overcurrent protection relay with self powered and dual powered (self

More information

MMT330 Series Moisture and Temperature Transmitters for Oil

MMT330 Series Moisture and Temperature Transmitters for Oil MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala

More information

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.

More information

Page 5-3. Page 5-2 Page 5-3

Page 5-3. Page 5-2 Page 5-3 Page -2 Page -3 Page -3 ADXC Two phase control IEC rated starter current Ie 12 to 4A IEC rated motor power.-22kw at 400VAC and 9-37kW at 600VAC UL/CSA ratings 3 to 2HP at 400VAC and 10 to 40HP at 600VAC

More information

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement.

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement. MID Energy Counters Getting together is a beginning, staying together is a progress, working together is an achievement. Henry Ford New UEM series: Energy meters with on-board communication UEM1P5 three

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

DIRIS N300/N600 Network analysers Network quality control and analysis system

DIRIS N300/N600 Network analysers Network quality control and analysis system Metering, monitoring & power quality Function DIRIS_755_a_1_cat DIRIS_762_a_1_gb_cat DIRIS N300 / N600 are multifunction network analysers designed for in-depth analysis of electrical networks in order

More information

DATA SHEET Selectable AC transducer, TAS-331DG

DATA SHEET Selectable AC transducer, TAS-331DG DATA SHEET Selectable AC transducer, TAS-331DG Measures power or reactive power on 3-phase AC networks Class 0.5 (IEC-688) measurement Supply and measuring voltage up to 690 V Easy configuration via PC

More information

Industry 4.0. Competitiveness, Digitalisation and Efficiency. Technology for energy efficiency. A range of essential products for INDUSTRY 4.

Industry 4.0. Competitiveness, Digitalisation and Efficiency. Technology for energy efficiency. A range of essential products for INDUSTRY 4. Industry 4.0 Competitiveness, Digitalisation and Efficiency A range of essential products for INDUSTRY 4.0 Technology for energy efficiency Energy efficiency is the key to improving competitiveness and

More information

NPW800R RETROFITTING. Power and Volatge Protection Relay

NPW800R RETROFITTING. Power and Volatge Protection Relay RETROFITTING Power and Volatge Protection Relay NPW800R (R3 case) is dedicated to the refurbishment of CEE WTG 7000 relays (R3 case) providing the measurement of apparent (S), active (P) and reactive (Q)

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information