Tamper-Resistant and Weather Resistant Receptacles the new standard in electrical safety.
|
|
- Carmel Hutchinson
- 5 years ago
- Views:
Transcription
1 and Receptacles the new standard in electrical safety.
2 and Duplex Receptacles Why? The tamper-resistant code requirement is all about safety. Approximately 2,400 children per year suffer electrical outlet related injuries. For years, the design and use of tamper-resistant receptacles has been proven effective in pediatric areas and hospital installations nationwide. It makes sense to have them in homes as well. The additional cost per device is minimal and well worth it. Required by states that adopt 2008 NEC. Duplex Receptacles Complies with NEC Complies with NEC Complies with NEC c What Do These Code Requirements Mean? All 125V, 15A and 20A receptacles shall be listed tamper-resistant receptacles per NEC Article , " Receptacles in Dwelling Units". Schools Pediatric Healthcare Facilities These symbols appear throughout for easy identification. Lobbies Day-Care Centers () receptacles incorporate internal mechanisms to limit access to energized internal components. receptacles are a mandatory requirement in the 2008 NEC for use in dwelling unit outlets. There are also many other applications where the use of receptacles can provide an additional level of electrical safety such as Schools, Pediatric Facilities, Lobbies and Day-Care Centers. Duplex Receptacles Complies with NEC 406.8(A) All 125V and 250V, 15A and 20A receptacles shall be listed as weather resistant type per NEC Article 406.8, "Receptacles in Damp and Wet Locations". Transit Centers Washdown Areas Amusement Parks Open Air Markets () receptacles installed outdoors or in wet and damp locations are subject to more demanding temperature variations, direct sunlight and unusual mechanical abuse than those in a typical dry environment. Bryant s receptacles are specifically designed to withstand these environments and conditions.
3 Ground Fault Receptacles Patented tamper-resistant protection Limits improper access to energized contacts No power at face if reverse wired Flashing RED LED, indicates device has lost capability to provide ground fault protection Open terminal design Accepts fork terminals Automatic grounding feature and internal back wire facilitate installation Commercial & Hospital Grade Ground Fault Receptacles Office Red Office Red Commercial Grade GF15AL GF15BK GF15 GF15GY GF15I GF15LA GF15OW GF15R GF15W GF20AL GF20BK GF20 GF20GY GF20I GF20LA GF20OW GF20R GF20W Hospital Grade GF82AL GF82BK GF82 GF82GY GF82I GF82LA GF82OW GF82R GF82W GF83AL GF83BK GF83 GF83GY GF83I GF83LA GF83OW GF83R GF83W
4 Commercial Grade Receptacles Fashion Series Self-grounding staple for fast and easy installation Durable construction using nylon face and base Easy access split circuit tab Accepts fork terminals Fashion Series provides modern architectural appearance Decorator face Sturdy construction wrap-around galvanized steel strap Commercial Grade Fashion Series Receptacles DRS15AL DRS15BLK DRS15 DRS15GRY DRS15I DRS15LA DRS15WHI DRS15AL DRS15BLK DRS15 DRS15GRY DRS15I DRS15LA DRS15W DRS15AL DRS15BLK DRS15 DRS15GRY DRS15I DRS15LA DRS15W DRS20AL DRS20BLK DRS20 DRS20GRY DRS20I DRS20LA DRS20WHI DRS20AL DRS20BLK DRS20 DRS20GRY DRS20I DRS20LA DRS20W DRS20AL DRS20BLK DRS20 DRS20GRY DRS20I DRS20LA DRS20W
5 Commercial Grade Receptacles Standard Duplex Single tab breakoff ears Self-grounding staple Nylon face and base Bryant Snub Hole for fast and easy side wiring Accepts fork terminal Easy access split circuit tab Sturdy construction with wrap-around galvanized steel strap Commercial Grade Standard Duplex Receptacles Side Wired CRS15AL CRS15BLK CRS15 CRS15GRY CRS15I CRS15LA CRS15W CBRS15AL CBRS15BLK CBRS15 CBRS15GRY CBRS15I CBRS15LA CBRS15W CBRS15AL CBRS15BLK CBRS15 CBRS15GRY CBRS15I CBRS15LA CBRS15W CBRS15AL CBRS15BLK CBRS15 CBRS15GRY CBRS15I CBRS15LA CBRS15W CRS20AL CRS20BLK CRS20 CRS20GRY CRS20I CRS20LA CRS20W CBRS20AL CBRS20BLK CBRS20 CBRS20GRY CBRS20I CBRS20LA CBRS20W CBRS20AL CBRS20BLK CBRS20 CBRS20GRY CBRS20I CBRS20LA CBRS20W CBRS20AL CBRS20BLK CBRS20 CBRS20GRY CBRS20I CBRS20LA CBRS20W
6 Bryant Quick-Tech Duplex Receptacles Bryant s new Quick-Tech receptacle provides a quick and simple method to wire a receptacle! Quick-Tech Pigtailed Terminal QT6R1 Description Clear Connector with 6" Leads - Solid Wire Clear Connector with 6" Leads - Stranded Wire Catalog Numbers QT6R1 QT6R2 Quick-Tech Specification Grade Duplex Receptacles Dimensions Inches (mm) Red QT5262AL QT5262BK QT5262 QT5262GY QT5262I QT5262LA QT5262R QT5262W QT5362AL QT5362BK QT5362 QT5362GY QT5362I QT5362LA QT5362R QT5362W 2.62" (66.5) 1.56" (39.7).24" (6.1) 3.28" (83.3).86" (21.9) QT5262I Quick-Tech Hospital Grade Duplex Receptacles Dimensions Inches (mm) Red QT8200AL QT8200BK QT8200 QT8200GY QT8200I QT8200LA QT8200R QT8200W QT8300AL QT8300BK QT8300 QT8300GY QT8300I QT8300LA QT8300R QT8300W 2.62" (66.5) 1.56" (39.7).24" (6.1) 3.28" (83.3).86" (21.9) QT8200W
7 Receptacles Residential Performance Protection is always available with tamper-resistant receptacles. They are reliable, automatic and permanent. With attention to design and performance, Bryant has developed a new shutter mechanism to enable tamper-resistance to be built into standard and decorator duplexes, single receptacles, floor boxes and other power devices. At Bryant, performance is our history, safety is our goalnow for your home. Standard Duplex Self-Grounding RR15SAL RR15SBK RR15S RR15SI RR15SLA RR15SW Standard Duplex Quick Thread RR15QAL RR15QBK RR15Q RR15QI RR15QLA RR15QW Decorator Duplex Self-Grounding RRD15SAL RRD15SBK RRD15S RRD15SGY RRD15SI RRD15SLA RRD15SW Standard Duplex Cut Ears RR15KAL RR15KBK RR15K RR15KI RR15KLA RR15KW Standard Single Receptacle RR151AL RR151BK RR151 RR151GY RR151I RR151LA RR151W Standard Single Receptacle RR201AL RR201BK RR201 RR201GY RR201I RR201LA RR201W Decorator Single Receptacle RRD151AL RRD151BK RRD151 RRD151GY RRD151I RRD151LA RRD151W Decorator Single Receptacle RRD201AL RRD201BK RRD201 RRD201GY RRD201I RRD201LA RRD201W Standard Combo SP Switch 15A 120V Receptacle RC108AL RC108 RC108I RC108LA RC108W Standard Combo 3W Switch 15A 120V Receptacle RC308AL RC308 RC308I RC308LA RC308W Decorator Combo SP Switch 15A 120V Receptacle RCD108AL RCD108BK RCD108GY RCD108I RCD108LA RCD108W Decorator Combo 3W Switch 15A 120V Receptacle RCD308AL RCD308BK RCD308GY RCD308I RCD308LA RCD308W
8 and Receptacles the new standard in electrical safety. Contact Information Regional Managers Northeast Region Dave Jones Office: Fax: Southeast Region Tony Scenna Office: Fax: Midwest Region Randy Sengbusch Office: Fax: Northwest Region Erich Leaverton Office: Fax: Southwest Region Rick Carlson Office: Fax: National Account Manager Modular/Mobile Homes & Recreational Vehicles Glenn Jensen Office: Customer Service/ Technical Service For a searchable list of authorized distributors and sales agents, visit our website at Printed In U.S.A. Specifications subject to change without notice. Registered trademark of Hubbell Incorporated. Bryant 185 Plains Road Milford, CT Phone (800) FAX (800) BPB107
SNAPConnect. Savings and Productivity Are Just a SNAP Away
SNAPConnect Savings and Productivity Are Just a SNAP Away Receptacles Switches GFCI LED Power Tamper-Resistant Style Line Decorator Isolated Ground Surge Suppression Table of Contents Labor Savings Feature
More informationSNAPConnect Devices. Savings and Productivity Are Just a SNAP Away. Hospital Grade. Specification Grade Receptacles. Split Circuit
SNAPConnect Devices Savings and Productivity Are Just a SNAP Away Hospital Grade Specification Grade Receptacles Split Circuit Style Line Decorator Single Receptacles GFCIs USB Charging Receptacles Permanently
More informationA Complete Floor Box System for Concrete
A Complete Floor Box System for Concrete Leviton has it all. From the floor box itself to the devices inside, our system delivers superior electrical power, AV and networking solutions. Delivering The
More informationSECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationHealthcare Solutions P&S. designed to be better. Dependable performance and safety.
P&S Healthcare Solutions Dependable performance and safety. designed to be better. Quality Hospital grade devices you can count on. Auto-ground clip ensures ground connection. One-piece brass mounting
More informationUL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices. Wiring Device-Kellems
UL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices Wiring Device-Kellems Industrial Surge Protection Healthcare Wiring Device-Kellems Healthcare Facility Outlet Assemblies
More informationSECTION WIRING DEVICES
PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 REFERENCES... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS... 2 2.1
More informationSECTION WIRING DEVICES
SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationDuplex Convenience Receptacles
PDHonline Course E292 (2 PDH) Duplex Convenience Receptacles Instructor: David A. Snyder, PE 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationEmery County Senior Center Green River 06/07
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationFall Test 21 due 12/11/2012
Fall Test 21 due 12/11/2012 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Emergency system transfer equipment, including automatic transfer switches,
More informationAutomatic Receptacle Control Product Guide
Wiring Device-Kellems Automatic Receptacle Control Product Guide Power when you need it Energy savings when you don t Load:Logic Automatic Receptacle Control (ARC) 2017 National Electrical Code Change
More informationFor (2) Single Receptacles: dia. Hole Standard Depth
6000 Series - Portable Outlet Boxes 6002 NOTICE: The NEC restricts the use of metal job boxes as temporary power cords 6000 6000 Series Portable Outlet Boxes Rugged and durable, these outlet boxes are
More informationCombo 2 Port Usb Receptacle 15A 125V Iv 15A 125V 2P IV USB RECEPT COMBO 2 PORT USB RECEPTACLE 15A 125V IV
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com TR7740VB0X 15A 125V 2P Iv Usb Recept Cooper Wiring Devices Catalog Number Manufacturer
More informationDescription GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SGFH20B Gfci HG ST Duplex 20A 125V BR Eaton Wiring Devices Catalog Number SGFH20B Manufacturer Eaton Wiring Devices Description
More informationSECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.
SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,
More informationNEC 2008 Code Changes Top 20 Revisions. By: Rafi Wartan, PE, LEED AP
NEC 2008 Code Changes Top 20 Revisions By: Rafi Wartan, PE, LEED AP #1 Article 210.4 MULTIWIRE BRANCH CIRCUITS The rule on simultaneous disconnecting means requirements for multiwire branch circuits was
More information20AMP Plug Load Controller
Project name Prepared by Date INDOOR AIRLINK LUTRON Catalog#: ALPP 20A or ALPP 20ACC Part #: 624097 or 655228 The 20AMP plug load controller is a radiofrequency (RF), receptacle switching solution that
More informationFigure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.
Surge Arresters Storm Trapper H.E. (High Energy) Low-Voltage Distribution-class MoV Surge Arrester Electrical Apparatus 235-16 GEnErAL Cooper Power Systems Storm Trapper H.E. (High Energy), lowvoltage
More informationBulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010
Ontario Electrical Safety Code - Bulletins 50-1-0 Bulletin 50-1-0 Installation of Solar Photovoltaic Systems Section 50; Rules: 84-020, 84-024, 84-030; Tables 11 and 19 Issued July 2010 Scope (1) Introduction
More informationSpring Test 9 due 05/11/2013
Spring Test 9 due 05/11/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A grounding electrode is. a. a solid conductor b. a circuit conductor that
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationLITE TUNES #V
LITE TUNES #V45000-71 Thank you for purchasing this new Sylvania LITE TUNES. This LITE TUNES assembles in minutes. The LITE TUNES: CARTON INCLUDES: 1 Litetunes 2 Remote controls 1 Set ground stake 1 Audio
More informationUser s Manual. LumiVision series. A Designer s X-ray film illuminator. Walnut, CA U.S.A. By LCD TV Technology
User s Manual A Designer s X-ray film illuminator By LCD TV Technology series Point A Technologies, Inc. Walnut, CA U.S.A. FCC RF INTERFERENCE STATEMENT NOTE: This equipment has been tested and found to
More informationASCO SERIES 300 Manual Transfer Switch Solutions
ASCO SERIES 300 Manual Transfer Switch Solutions When power fails, businesses suffer. For some organizations, a permanent generator is too costly. Instead, permanent means for quickly connecting a portable
More informationSECTION SECTION. EATON 2016 Arrow Hart Buyers Guide
1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart Hospital Grade Devices Table of contents Hospital grade families -7 ArrowLink modular connectors -8, -9 Tamper resistant device options
More informationElastimold Molded Vacuum Recloser - MVR
Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical
More informationPowerLogic ION7300 Series
PowerLogic ION7300 Series Power and Energy Meter Advanced Field Retrofit Instructions August 2006 Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure
More informationONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications
For over 50 years, BWF/M. Stephens has been a leader in the die casting industry. With the full line of outdoor weatherproof products, BWF/M. Stephens is committed to offering the high quality and customer
More informationRecp HG Ig SGL 20A 125V 2P3W STR B&S or
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 IG8310RN Recp HG Ig SGL 20A 125V 2P3W STR B&S or Catalog Number Manufacturer Weight per unit Product Category IG8310RN
More informationUNDERCARPET CABLING SYSTEM For Power and Communications
UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007 Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications
More informationGround Fault Products Straight Blade Automatic and Manual Set Portable GFCI Line Cords Features and Benefits
Ground Fault Products Straight Blade Automatic and Manual Set Portable GFCI Line Cords Features and Benefits Circuit Guard Set GFCI Line Cord Portable GFCI Line Cords provide ground fault protection both
More informationELCO Memory Card Components
ELCO Memory Card Components Table of Contents ELCO PCMCIA PC Memory Card Components Host Device Components Introduction... 3 Features & Benefits... 4 PC Memory Card Components Selection Guide...5 Host
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 2726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information24V Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 24VCC Part #:
Project name Prepared by Date INDOOR AIRLINK LUTRON Catalog #: ALPP 24VCC Part #: 665142 The 24V power pack is a low-voltage radio frequency (RF) controller that provides a single dry contact closure output
More informationPOWER CABLES FOR MISSION CRITICAL FACILITIES
POWER CABLES FOR MISSION CRITICAL FACILITIES UL LISTED, MISSION-CRITICAL POWER CABLES MANUFACTURED AND TESTED IN A CONTROLLED ENVIRONMENT With 24-Hour Turn-Around, an unprecedented number of receptacles,
More informationIEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and
IEC 60309 H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and amperage to prevent interchangeability of voltages Watertight
More informationGOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved
GOLDENI 600 model# GOLDi600 English Copyright 2017 Smart Grow Technologies, INC All Rights Reserved Owners Manual & Safety Instructions INTRODUCTION This User Manual is for Smart Grow Technologies (SGS):
More informationAl uminum Raceway is sleek, clean and
Architectural Aluminum Raceway AL5200 Aluminum Raceway Al uminum Raceway is sleek, clean and attractive. Integrated into casework or lab furniture or installed as baseboard, these raceways distribute communication
More informationCableSmart Series Nonmetallic Raceway
CableSmart Series Nonmetallic Raceway Dual-Channel 40N2 Series Nonmetallic Raceway System FIBER OPTIC CAT5 Wiremold CableSmart 40N2 Series Raceway is a large capacity nonmetallic raceway system that offers
More informationPCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer
Installation Instructions PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Catalog Number 6189V-2PCI15R Topic Page About This Publication 1 Important User Information 2 Safety
More informationPV Module Installation Instructions
Name 1601A Page 1 / 8 Name 1601A Page 2 / 8 1 Introduction Thanks for purchasing PV modules of HT SOLAR ENERGY JOINT STOCK COMPANY This manual refers to PV modules manufactured and sold by HT Turkey. This
More informationInstallation Guide for America Solar Wholesale Photovoltaic Modules
Installation Guide for America Solar Wholesale Photovoltaic Modules Mono Module Poly Module 1 ASW Photovoltaic Module Installation Guide Installation guide for American Solar Wholesale Photovoltaic modules
More informationGround Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /
2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power
More informationGFCIs. Index. GFCIs. P&S innovations from the first GFCI receptacle to SafeLock Protection. E-1
P&S innovations from the first GFCI receptacle to SafeLock Protection. In 1971, we introduced the first GFCI receptacle. Soon, our invention was preventing injuries and saving lives throughout North America.
More informationHospital Grade GFCI Receptacles
Hospital Grade GFCI Receptacles 2 Pole, 3 Wire Grounding 15 & 20A, 125VAC 1595-HGW SafeLock TM Protection: if critical components are damaged and ground fault protection is lost, power to receptacle is
More informationNew ways to increase profit margins.
P&S PlugTail Wiring Devices New devices. New upgrade opportunities. New ways to increase profit margins. complete line ble on any commercial job. Introducing P&S PlugTail Sensors and Surge Protection Devices.
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationBuildingName The Description of the Project P DOCUMENTS
P00000000 0000 DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationHi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System
Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL For the 4600 Scale System For the 5600 Scale System September 1999 THE ACCURATE ON-BOARD ELECTRONIC SCALE For Air-Ride
More informationGolight Radioray GL-2000-F Flood & Spot Light Combo - wireless remote control - permanent mount
Golight Radioray GL-2000-F Flood & Spot Light Combo - wireless remote control - permanent mount Part #: GL-2000-F Page: 1 The GL-2000-F Golight Radioray from Larson Electronics is a 65 Watt motorized spotlight/floodlight
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationSECTION WIRING DEVICES
SECTION 26 27 26 WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Receptacles, receptacles with integral GFCI, and associated device plates. 2. Twist-locking receptacles.
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationMELTRIC Corporation. The best in industrial wiring devices. Product Technology & Safety. Value
MELTRIC Corporation The best in industrial wiring devices At MELTRIC Corporation, our only business is electrical plugs and receptacles. We are focused on providing our customers with the best overall
More information1. Unpacking the System
1. Unpacking the System To prevent shipping damage the system is packed in multiple boxes. Chassis The chassis in shipped in one box by itself. The chassis is shipped assembled. Inside the chassis you
More informationMOBILE CONNECTOR - GEN 2 OWNER'S MANUAL
MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector
More informationThis Wiremold aluminum raceway system meets the
Architectural Aluminum Raceway AL3300 Aluminum Raceway This Wiremold aluminum raceway system meets the demands of today's commercial spaces, providing a compact, handsome and effective method of consolidating
More information2.7 UNDER-CARPET WIREWAY
2.7 UNDER-CARPET WIREWAY U.S. List Pricing SO SUBTLE IT VIRTUALLY DISAPPEARS Connectrac 2.7 Under-Carpet Wireways. Completely concealed by carpet tile, they are Connectrac s lowest, sleekest, most invisible
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationSingle Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL
Trinetics UltraVacLT Single Phase Vacuum Capacitor Switch Installation and Operation Instructions UltraVacLT 15kV 95kV or 125kV BIL UltraVacLT 27kV 125kV or 150kV BIL Hubbell has a policy of continuous
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationCOOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN
Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER
More informationControl Your World. Lighting Control System
Lighting Control System Control Your World Today s homes have a wide variety of lights, dimmers and switches, indoors and out. Lighting control provides convenience, cost savings and an extra measure of
More informationPRO-75 SERIES. User manual
PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationWith its tamper-resistant design, the
Dual-Channel 40N2 Series Nonmetallic Raceway Systems CableSmart Series Nonmetallic Raceway With its tamper-resistant design, the CableSmart 40N2 Series Raceway is ideal for schools or office settings,
More informationSECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service
More information10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting
10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C1 BELL Weatherproof Boxes, Covers, and Lighting 10 Pg C1 - C-30.qxp 6/9/2008 10:43 AM Page C2 C2 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ pí~åç~êçë _Éää Δ
More informationCopy Machine Reader. Installation and Setup Guide
Copy Machine Reader Installation and Setup Guide CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications
More information3M Stikit Disc Roll Paper
16 General Use 415U/415N Silicon carbide A wt. Paper General purpose discs for whitewood and sealer sanding Unique construction provides excellent finish Convenient disc roll form, 125 or 250 discs per
More informationInstallation Instructions 4291 and 4292 Keypads
Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the
More information1.4. Electronic Products. Contents Description E33 esm Keypad Multiplexed Switch Module Product Selection...
.4 Electronic Products Product Description Sealed Multiplexed Master Module using a LIN sub bus to communicate with up to seven expansion modules. Eaton is pleased to introduce the newest line of multiplexed
More informationICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT
Return Address MACKENZIE LABORATORIES, INC. Nicole Court Glendora, CA 0 USA ICM- INPUT CONTROL MODULE, INPUTS RS-(SERIAL) OUTPUT ------------------------------------------------------------------------------------------------------------------
More informationBrite Star Symphony of Lights Projector Light Show
Page 1 Brite Star Symphony of Lights Projector Light Show Page 2 - Search Symphony of lights projector on Google Play Store/I-tunes to download the app. How to connect your device to projector 1. click
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationPRO-1250D CT MID DIN rail three phase four wire energy meter.
PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions
More informationCompact plugs and receptacles standard or high temperature rated
PN Features and Ratings p. 118 PN20 p. 119 PN20 High Temp p. 121 Spare parts p. 123 Dimensions p. 125 Compact plugs and receptacles standard or high temperature rated PN Series plugs and receptacles offer
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Power Connectors FEATURES AND SPECIFICATIONS Features and Benefits Positive
More informationThe six major components of a structured wiring system are:
OBJECTIVES 1. Describe various ANSI/TIA/EIA standards for commercial buildings and residential settings. 2. Discuss the specific Technical Systems Bulletins that can affect telecommunications installations.
More informationSolid State Relays and Timers Family
Solid State Relays and Timers Family Vehicle Control Modules Waytek Stock No. Volt Rating Amp Rating Notes Dual Input Relay Activating either Input A or Input B sets output. 75532 12 15 Dual inputs Latching
More informationMODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT
MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state
More informationWhy is my AFCI tripping?
www.garyklinka.com Page 1 of 21 Instructions: Fee $25 1. Print these pages. 2. Use the included information located on pages 12-20 to answer the 61 questions below. 3. Circle the correct answers and transfer
More informationThe General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.
SECTION 16420 - ELECTRICAL EQUIPMENT PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified
More informationPreparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management
Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More information28-Position 23 Rack Mounting Model RM23-20X
001-0048 Rev.00 28-Position 23 Rack Mounting Model RM23-20X SECTION PAGE # 1. GENERAL... 1 2. APPLICATIONS... 1 3. INSTALLATION... 1 4. TESTING... 3 5. CUSTOMER SERVICES... 3 6. WARRANTY AND REPAIRS...
More informationLeviton Products Referenced in the Rockwell Automation ENCOMPASS Program
Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program Power Solutions for Industrial Automation Surge Protection & Power Connection Surge Protection Leviton s network approach to facility-wide
More informationAPPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017
APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6
More informationGreat Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)
Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI) GROUND FAULT CIRCUIT INTERRUPTERS Wiring design and protection. - 1926.404 Our company uses ground fault circuit
More informationPower/Data Instructions. Genius. Movable Walls. September
Power/Data Genius Movable Walls September 2011 Genius Movable Walls Power and Data in Shell Level 1 Conventional Boxes in Panel (conventional box and conduit) Choose 2x4 box or 4x4 box (shown). Separate
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationAC Capacitors for HID Lighting Applications
GTC 002 2011 AC Capacitors for HID Lighting Applications Proven EIA-456 Compliant 60,000 Hour Reliability Industry Standard Genteq Capacitors 1946 West Cook Road, Fort Wayne, Indiana 46818 USA Phone: (260)
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationTesla TI Generator Set Interface
Power Anytime, Anywhere Tesla TI2000-440 Generator Set Interface User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912
More informationDP2 DOOR PHONE. For Technical Assistance Please Phone: (07)
DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary
More informationATOM. Instruction Manual. Head. from software version: 8.
Instruction Manual from software version: 8 ATOM Head support@glp.de www.glp.de Contents 1 Description of Device... 3 2 Safety Instructions... 4 3 Mounting... 6 3.1 Operating on the Floor (Upright)...
More informationNew ways to increase profit margins.
P&S PlugTail Wiring Devices New devices. New upgrade opportunities. New ways to increase profit margins. P&S PlugTail Wiring Devices the most complete line to keep you profitable on any commercial job.
More information