The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

Size: px
Start display at page:

Download "The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven"

Transcription

1 1

2 2

3 3

4 4

5 The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven SEL-300G Generator Relay with the SEL-700 series platform features. Additionally, an automatic synchronizer function eliminates the need for standalone synchronizer equipment. 5

6 The SEL-700GT Intertie Protection Relay provides a complete intertie protection solution for distributed generation. With optional synchronous generator protection and synchronization, this relay provides complete generator and intertie protection in one compact and economical package. The SEL-700GT provides IEEE 1547-compliant protection for any type of distributed generation, including gas turbine, diesel, methane recovery, wind, and photovoltaic. Phase differential (87), compensator distance (21C), out-of-step (78), and 100 percent stator ground (64G) protection are not available with the SEL-700GT. Use the appropriate SEL-700G model for applications that require any of these protection elements. 6

7 The SEL-700GW Wind Generator Relay is a complete feeder protection solution for distributed generation. The SEL-700GW provides high system availability by using two sets of overcurrent elements (50/51) to detect and isolate a fault on either feeder. The SEL-700GW also provides many of the functions of a programmable logic controller (PLC). Multiple communications options, a variety of I/O choices, and programmable SELOGIC control equations make the SEL-700GW a complete solution. 7

8 8

9 ANSI device number functions included in the standard SEL-700G0 model include the following: Volts-per-hertz element (24) Undervoltage (27) Reverse/low forward power (32) Loss-of-field (40) Directional ground overcurrent (67G) Negative-sequence overcurrent (46) Thermal element (49T) Neutral overcurrent (50N/51N/51G) Phase overcurrent (50P) Voltage-controlled/voltage-restrained time-overcurrent (51C/51V) Overvoltage (59) Overfrequency and underfrequency elements (81) Restricted earth fault (REF) Ground differential element (87N) 9

10 Optional ANSI device number functions included in the SEL-700G include the following: Backup mho phase distance element (21) Synchronism check (25) 100 percent stator ground elements (64G) Out-of-step protection (78) Current differential elements (87) Second set of phase overcurrent (50P) 10

11 All SEL-700G models include IEEE C compliant synchrophasors for system state, response, and control capabilities. Selected SEL-700G models have the built-in automatic synchronizer function, which provides output contact interfaces for the generator field voltage regulator and the prime mover speed control governor. Frequency, voltage, and phase control of the generator is automatically synchronized and connected to the power system with this function. The thermal model provides protection from generator overheating due to excessive positiveand negative-sequence current draw. The thermal model is based on IEC If the RTD (resistance temperature detector) option is installed, the trip threshold can be biased for ambient temperature. Four independent rate-of-change-of-frequency elements are provided with individual time delays for use when frequency changes occur (e.g., when there is a sudden imbalance between generation and load). These elements call for control action or switching action, such as network decoupling or load shedding. Each element includes logic to detect either increasing or decreasing frequency and above or below nominal frequency. REF protection provides sensitive detection of internal ground faults on grounded wyeconnected windings. The neutral current CT (current transformer) provides the operating current. Polarizing current is derived from the residual current calculated for the protected winding. A sensitive directional element determines whether the fault is internal or external. 11

12 The SEL-700G offers high-performance features in a package economical enough for small machine protection. Consider using this relay by itself to protect 1 to 5 MW machines. In high-resistance grounded generator protection applications, the SEL-700G0+ can also provide 100 percent stator ground fault coverage if a neutral VT (voltage transformer, not shown) is included. (See the SEL-700G data sheet for complete model information.) The left picture on this slide shows a diesel generator plant, while the right picture shows standby generators, both of which can be protected with the SEL-700G. The one-line diagram represents the diesel generator application. There are multiple generators connected to the bus. The machine is a brush-type, salient pole rotor. 12

13 The SEL-700G1+ includes all of the protection functions of the proven SEL-300G, presently used to protect many of the world s largest generators. (See the SEL-700G data sheet for complete model information.) The one-line diagram shows a unit-connected generator. In addition to the functions available in the SEL-700G0, the SEL-700G1+ offers the following functions: Autosynchronizer Backup mho phase distance element (21C) Synchronism check (25) Synchronism check undervoltage (27S) RTD thermal elements (49RTD) Second set of phase overcurrent (50P) Synchronism check overvoltage (59S) 100 percent stator ground elements (64G) Out-of-step protection (78) Current differential elements (87) 13

14 The SEL-700G is a comprehensive, multifunction relay intended for primary and/or backup protection for any size synchronous machine. Alternatively, the SEL-300G can be used as backup for applications that require a different hardware platform for primary and backup protection. 14

15 The combination of fundamental neutral overvoltage (59N) and third-harmonic voltage differential (V3d) provides 100 percent stator ground fault coverage. The two elements are treated as independent protection zones (64G1 and 64G2), each with its own settable definite-time delay. Two important advantages of this method are the sensitivity and element overlap. The 59N element has good sensitivity for middle winding faults in the V3d element dead band. The V3d element detects low-winding faults that produce very little neutral fundamental voltage. Both elements detect faults in the upper area of the winding, providing two methods to detect more serious faults. 15

16 16

17 Each time a generator returns to service, it must synchronize to the power system before the interconnecting breaker can be closed. Synchronizing is the act of matching the magnitude and the frequency of the generator and system voltage and bringing the two voltages into phase alignment. IEEE C50.12 and IEEE C50.13 provide the synchronizing limits for salient pole and round rotor machines. Closing the interconnection breaker outside these limits may cause electrical and mechanical transients that can exceed those transients experienced during three-phase short circuits. 17

18 Generator and transformer mechanical damage can be caused by excessive currents that circulate through the windings. Damage to the windings and core lamination is possible. The prime mover and generator shafts are subjected to torsional stresses, possibly resulting in slippage of couplings, bearing misalignment, and fatigue damage to the shaft. Power system disturbances are caused by the transients in active and reactive power. 18

19 Selected SEL-700G models (SEL-700G0+ and SEL-700G1+) have a built-in automatic synchronizer function, which provides output contact interfaces for the generator field voltage regulator and the prime mover speed control governor. With this function, frequency, voltage, and phase control of the generator are automatically synchronized and connected to the power system. These relays also provide generator start reports to record the automatic synchronizing event. The generator synchronization process can be viewed on a PC-based synchroscope with ACSELERATOR QuickSet SEL-5030 Software. You can specify the SEL-700G with a built-in generator synchronism-check function (25G). The synchronism-check function is extremely accurate and provides supervision for an acceptable voltage window and maximum percentage difference, maximum and minimum allowable slip frequency, target closing angle, and breaker closing delay. 19

20 The SEL-700G autosynchronizer matches the frequency, phase angle, and voltage of a generator to that of the bus before allowing the generator breaker to be closed. In the example above, the SEL-700G monitors the generator frequency, phase angle, and voltage using the VAX, VBX, and VCX voltage inputs. (The SYNCPX setting determines the specific voltage input used.) Generator mechanical speed and the associated electrical frequency and phase angle are adjusted by sending raise/lower pulses to the governor. Generator voltage is adjusted by sending raise/lower pulses to the excitation system. The width of the raise/lower pulses are proportional to the difference between the actual and target magnitudes. As the slip frequency and/or voltage get closer to the target value, the width of the raise/lower pulses gets shorter to prevent hunting. The raise/lower pulses stop when the magnitude is within an acceptable window. When the synchronization conditions are satisfied (slip, voltage window, and voltage difference), the SEL-700G initiates a close, compensating for the present slip and breaker closing time. 20

21 ACSELERATOR QuickSet software provides a synchroscope display when connected to an SEL-700G. The synchroscope display emulates the familiar look of an electromechanical synchroscope device. This allows the observer to monitor the autosynchronization process. 21

22 The SEL-700G with automatic synchronizer function generates a generator synchronism report with all the relevant analog and digital signals to facilitate quick event analysis. The sample rate can be selected from 0.25, 1, and 5 cycles. The report captures 4,800 timestamped data points. 22

23 23

24 The IEEE 1547 standard is applicable to all distributed resource technologies with aggregate capacity of 10 MVA or less, interconnected to the electrical power system at primary or secondary distribution voltages. The standard focuses on radial primary or secondary distribution systems. The standard has been widely adopted in the United States, with a few exceptions in California, New York, and Texas. In 2008, IEEE was approved. It provides technical background and application details to support understanding of IEEE

25 The SEL-700GT provides an IEEE compliant solution to protect both the electric utility grid and distributed generation equipment. With the SEL-700GT, all IEEE 1547 requirements are met, including the following: Voltage-based protection Unintentional islanding protection Current-based protection with directional overcurrent Out-of-phase reclosing protection 25

26 The plus option adds synchronous generator protection and autosynchronization to provide complete generator and intertie protection in one compact and economical package. The SEL-700GT+ does the work of the following three devices: Interconnection relay Generator relay Autosynchronizer 26

27 Combining the SEL-700G with the SEL-2664 Field Ground Module offers the following features for field ground detection: Comprehensive generator protection in the SEL-700G. Sensitive, early detection of field ground faults. Easy installation with no settings in the SEL Noise-free electrical isolation through fiber-optic communication. Key benefits of the SEL-2664 include the following: Operates on most large or small generators. Configures to trip, warn, or simply monitor field ground resistance to match customer needs. Includes high-quality construction and the widest operating temperature range in the industry ( 40 to +85 C). Accurately detects field grounds, whether the generator is de-energized, stopped, or operating. The SEL-2664 has best-in-class accuracy of 5 percent or 500 ohms. The SEL-2664 has three mounting options: wall, panel, and rack. The rack mount includes an adapter plate and panel-mount unit. 27

28 The basic function of a synchronous machine rotor is to produce the rotating magnetic field necessary to induce voltage in the stator windings. The source for this magnetic field is the dc current that circulates through the field winding. Synchronous machine rotors are divided into two groups: round rotors and salient pole rotors. Round rotors are found in machines with high nominal speeds (1,800 to 3,600 rpm at 60 Hz), while salient pole rotors are common to machines with lower speeds (1,200 rpm and below at 60 Hz). There are some specific applications in which salient pole rotors are required to operate at 1,800 rpm (four-pole machines at 60 Hz). 28

29 This is an example of a round rotor in a machine shop. The body of the rotor is usually made of a single steel alloy forging. The coil slots that will receive the field winding are cut into the forging. Note the following details from the picture above: Number of poles: 4 Number of slots between adjacent poles: 12, indicating the existence of 6 coils per pole Coils are concentrically wound around the polar faces. For example, one coil will occupy the top and bottom yellow slots, another coil will occupy the top and bottom red slots, and so on. Each coil has several turns, and each turn may be made of one or two conductors. The coils will be connected in series for a total of 24 coils (4 poles 6 coils per pole). After exiting the upper red slot, the copper turns go through a 90-degree bend, are shaped around the rotor body, go through another 90-degree bend, and finally enter the bottom red slot. This region of the winding is called the end-winding region. 29

30 In the scheme shown above, a voltage square wave is injected onto the field, and the resulting current leakage to ground is measured. This measurement is used to estimate the ground resistance. If this calculated ground fault resistance is outside the predetermined normal range, then an alarm and/or trip is generated. Switched dc voltage injection is superior compared to the other methods because of the following: The voltage divider method requires the generator field to be excited measurement is difficult at or around null point. Both ac and dc injections have long-term corrosion problems because of leakage paths via bearings to ground, etc. Switched bipolar dc injection is at a very low frequency of 0.25 or 1 Hz. This lowfrequency signal overcomes field-to-ground capacitance without inducing corrosion. 30

31 A square wave with positive and negative magnitudes, Voscp and Voscn, is applied to the field winding circuit. Referring to the drawing on the previous slide, Rx is the rotor ground fault resistance, and Cfg is the capacitance from the field winding and ground. If there is no connection between the rotor and the ground (Rx equals infinity), no direct current will flow in the loop in the steady state, and the voltage across the sense resistor (Rs) will be zero. If there is a fault with resistance Rx, a current will flow in the loop, and a significant voltage will develop on the resistance Rx. Fault resistance Rx can then be calculated as a function of the voltage drop across resistor Rs. 31

32 SEL-700G rear serial ports include the following: Port 2: multimode (ST ) fiber-optic serial port Port 3: EIA-232 Port 4: optional Slot C serial communications card (SELECT EIA-232/485) If the application requires inputs from the SEL-2600 RTD Module, an SEL-2664, and an SEL communications processor, SEL recommends connecting the SEL-2600 to the fiberoptic serial Port 2. Connect the SEL-2664 using an SEL-2812MR Fiber-Optic Transceiver to the EIA-232 Port 3, and connect the SEL communications processor using the EIA-232 Port 4. 32

33 The SEL-700G, SEL-700GT, and SEL-700GW are members of the SEL-700 series platform of generator, motor, feeder, and transformer protection relays and include a common set of automation, measurement, and communications features. 33

34 The SEL-700G provides another product in the popular SEL-700 series product line. These relays are designed and tested to the same rigorous standards as the SEL-300 and SEL-400 series relays. 34

35 MIRRORED BITS communications technology provides bidirectional relay-to-relay digital communications. MIRRORED BITS communications can operate independently on up to two EIA-232 rear serial ports and one fiber-optic rear serial port on a single SEL-700G. Use MIRRORED BITS communications to transmit and receive information between the SEL-700G and other relays within the power plant to enhance coordination. In addition to comprehensive protection functions, the SEL-700G offers many features that add value, including the following: Comprehensive metering. Fundamental metering is provided for all currents, voltages, frequency, and calculated power quantities. Root-mean-square (rms) metering is provided for phase currents and voltages. Harmonic metering provides magnitude of current harmonics. Breaker-wear monitoring. Comprehensive reporting, including oscillography, load profiling, and SER (Sequential Events Recorder) reports. ACSELERATOR QuickSet software. 35

36 Customize the SEL-700G to suit your particular protection and control applications. SELECT I/O option cards include digital (contact) inputs and outputs, analog inputs and outputs, and RTD inputs. Communications card options are described on the previous slide. The SELECT I/O options can be ordered in new relays or installed in existing relays in the field. 36

37 37

38 Power supply options include: Vdc Vdc Vdc Multiple protocols are available on the Ethernet port(s): Modbus TCP, Telnet, and FTP, with optional IEC and DNP3 LAN/WAN (local-area network/wide-area network). The green Connectorized terminals offer the advantage of robust connections while minimizing installation and replacement time. Installing or removing the Connectorized terminals takes only a few minutes. All wiring remains connected to the terminal block. Connectorized terminals accept wire size 12 to 24 AWG. The voltage and current inputs use conventional screw-terminal blocks. Ring terminals are recommended for current inputs. 38

39 39

40 The SEL-700G uses a 200 MHz ColdFire microcontroller for the main processor. Removing heat from the very capable and fast microprocessor was a challenge that SEL answered with an SEL-patented, heat-sink design. The product is rated to +85 C (+185 F). The SEL-700G samples analog input waveforms at 32 samples per cycle and processes relay and protection logic at 4 samples per cycle. SEL tests the SEL-700G to rigorous industry compliance standards, including the following: CSA C22.2 IEC/EN (CE Mark) UL File Number E320062, Class I, Zone 2 Hazardous Location approved 40

41 Use the front panel to monitor power system data, view fault indications and event information, set the relay, and operate local control. There are eight LEDs (light-emitting diodes) that provide information on relay self-test and fault types. Six of the LEDs are programmable and have a slide-in card for changing labels. Seven navigation pushbuttons perform a variety of functions. These functions include changing relay settings, observing metered data, viewing event report summaries, checking relay internal status, exercising contact outputs for testing, and resetting targets. The pushbuttons allow easy maneuvering among menus displayed on the 2 x 16 character backlit LCD (liquid crystal display). Four programmable pushbuttons provide user inputs for control action. Start and stop functions are provided in the default settings, but any button action can be programmed. The pushbuttons also have eight independent LEDs to provide programmable indication for I/O, logic, or group settings. 41

42 42

43 The SEL-700G provides comprehensive metering. Fundamental metering is provided for all currents, voltages, frequency, and calculated power quantities. RMS metering is provided for phase currents and voltages. Refer to the SEL-700G instruction manual for details on all of the metering available in the SEL-700G. 43

44 Gain added value provided by event reports, SER, monitoring, and metering functions. Reduce operating costs with extensive reporting, metering, and monitoring of operational and protection events. Gain an unmatched view of performance during critical events with the SEL-700G comprehensive reporting, which includes the following features: The load profile feature allows you to select up to 17 from the approximately 180 available analog quantities. Sample at 5-, 10-, 15-, 30-, or 60-minute intervals. Over 4,000 time samples are stored in nonvolatile memory. Raw or filtered event reports (32 samples per cycle or 4 samples per cycle) allow you to select from 180-, 64-, or 15-cycle event reports stored in nonvolatile memory. Up to 1,024 most recent entries are stored in the SER. 44

45 The SEL-700G complies with the IEEE C Standard for Synchrophasors for Power Systems. The protocol is available on Serial Ports 2, 3, 4, and F by setting the corresponding port setting to PROTO := PMU. SEL-700G synchrophasors include the following features: Frequency and df/dt 60 messages per second 9 currents 9 voltages 4 math variables 16 SELOGIC control equation variables IEEE C Level 1 accuracy 45

46 46

47 The SEL-700G contains a comprehensive set of 32 SELOGIC control equations, local and remote control bits, and counters. 47

48 SELOGIC control equations add great flexibility to the SEL-700G to create specialized logic for control or protection. Enhanced SELOGIC control equations use Relay Word bit names to create Boolean logic equations. The equations accept several logical operators for combining Relay Word bit names. These operators are shown on the slide. Using Relay Word bits, the equations can take on a great degree of complexity when applications require these capabilities. The output of each equation is a logical 1 (true) or logical 0 (false), depending on the logic state of each Relay Word bit and the relationship of these bits as defined by the operators. Many settings in the SEL-700G are in the form of SELOGIC control equations. The factoryset default values can be modified to support specialized protection and automation functions. 48

49 49

50 The relay chassis contains three expansion slots (C, D, and E) for adding the option cards. Add the following communications options: Ethernet (10/100BASE-T copper, 100BASE-FX fiber) IEC Modbus TCP DNP3 LAN/WAN Telnet and FTP Serial MIRRORED BITS communications Modbus RTU (multisession) DNP3 serial SEL ASCII EIA-485 port EIA-232 port DeviceNet communications card Extensive communications and software capabilities are possible. Communicate seamlessly with built-in SEL ASCII, MIRRORED BITS communications, Event Messenger, IEEE C protocol (synchrophasor data), Modbus RTU, and optional Ethernet with IEC 61850, Modbus TCP, DNP3 serial or LAN/WAN, and DeviceNet protocols. Quickly and easily set the SEL-700G with the included ACSELERATOR QuickSet software. Concurrent Ethernet sessions include: (2) Telnet, (2) FTP, (6) IEC 61850, (3) DNP3, and (2) Modbus. 50

51 51

52 Gain even more value from the SEL-700G via convenient product accessories. 52

53 53

54 The SEL-700G operates over a 40 to +85 C ( 40 to +185 F temperature range and features a worldwide, ten-year product warranty. As an ISO 9001:2008-certified company, SEL builds in reliability by using superior design processes. 54

55 55

Maximize process uptime with the SEL-patented motor thermal model.

Maximize process uptime with the SEL-patented motor thermal model. SEL-710 Motor Protection Relay Maximize process uptime with the SEL-patented motor thermal model. Optimize motor performance with separate thermal models for the stator and rotor. Monitor stator and ambient

More information

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.

More information

A low-cost, economical solution for distribution feeder protection

A low-cost, economical solution for distribution feeder protection SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status

More information

2 ms arc-flash protection and feeder relay in one platform

2 ms arc-flash protection and feeder relay in one platform Feeder Protection Relay 2 ms arc-flash protection and feeder relay in one platform Combine light sensor inputs with high-speed overcurrent protection to achieve secure arc-flash protection in as fast as

More information

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating Advanced Line Differential Protection, Automation, and Control System Combine subcycle line protection with traveling-wave fault locating Subcycle differential and distance protection minimizes damage

More information

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.

More information

Comprehensive protection for large, medium, and small generators

Comprehensive protection for large, medium, and small generators SEL-700G Generator Protection Relay Comprehensive protection for large, medium, and small generators Provide primary and backup generator protection with current, voltage, frequency, distance, power, and

More information

Advanced distribution feeder solution with integrated protection, monitoring, and control

Advanced distribution feeder solution with integrated protection, monitoring, and control Protection System Advanced distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions. Keep track

More information

Protect induction and synchronous motors with one relay.

Protect induction and synchronous motors with one relay. SEL-710-5 Motor Protection Relay Protect induction and synchronous motors with one relay. Patented, accurate thermal protection improves motor availability for production. Synchronous motor protection

More information

High-speed transformer differential protection for up to five terminals

High-speed transformer differential protection for up to five terminals Transformer Protection Relay High-speed transformer differential protection for up to five terminals Advanced differential protection and three restricted earth fault (REF) elements minimize damage and

More information

Lightweight and flexible recloser control for single-phase applications

Lightweight and flexible recloser control for single-phase applications SEL-35S Kestrel Single-Phase ecloser Control Lightweight and flexible recloser control for single-phase applications Plug-and-work operation with popular single-phase reclosers simplifies new and retrofit

More information

Protect induction and synchronous motors with one relay

Protect induction and synchronous motors with one relay SEL-710-5 Motor Protection Relay Protect induction and synchronous motors with one relay Patented, accurate thermal protection improves motor availability for production. The 5-inch, 800 480 color touchscreen

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

2 ms arc-flash protection and feeder relay in one platform

2 ms arc-flash protection and feeder relay in one platform Feeder Protection Relay 2 ms arc-flash protection and feeder relay in one platform Directly monitor and control your system using the 5-inch, 800 480 color touchscreen display. Prevent insulation damage

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system SEL-451 Protection, Automation, and Bay Control System Advanced feeder protection and complete substation bay control in one economical system Customize distribution protection using multiple instantaneous,

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

Numerical motor protection in medium voltage networks Motor Protection and Control REM620 Guideform Specification 1MRS758530 A Numerical motor protection in medium voltage networks Motor Protection and Control REM620 The configurable motor management relay is intended for protection, control,

More information

One relay for safety and process continuity

One relay for safety and process continuity Motor Management Relay One relay for safety and process continuity Improve safety at each motor control center (MCC) with secure, fast arc-flash detection. Use the enhanced thermal model for more precise

More information

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit

More information

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 PC83 and PC830 series devices are designed to perform the relay protection functions and 6-154 kv networks automation, have different functionality

More information

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent

More information

GPM500 Generator Protection Module

GPM500 Generator Protection Module GPM500 Generator Protection Module Generator Protection Module GPM500 The microprocessor based Generator Protection System GPM500 performs the protection and control of medium and low voltage generators

More information

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks GUIDEFORM SPECIFICATION Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks The freely configurable relay is intended for protection, control, measurement

More information

Modular Smart Grid Power Systems Simulators (Utilities)

Modular Smart Grid Power Systems Simulators (Utilities) Modular Smart Grid Power Systems Simulators (Utilities) AEL-MPSS SCADA Key features: Several Utilities and Final User options. Modular and scalable applications (from simple to advance complexity). Scalable

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485 Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, RS-485 Main Range of product Product or component type Relay application Device short name [Us] rated supply voltage Type of

More information

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power Systems Communications Implementation of IEC61850 in a Substation Environment Power Systems Communications Implementation of IEC61850 in a Substation Environment 26 October 2009 Reference VEE4700-01 Revision 0 Document Control Document ID: DOCUMENT1 Rev No Date Revision Details

More information

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application

Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Midwest Energy, Inc. Distributed Generation Interconnection Expedited & Standard Process Application Instructions To submit an application to interconnect a generating facility using the Expedited or Standard

More information

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS Armando Guzmán Schweitzer Engineering Laboratories, Inc. Pullman, WA 99163 A reliable power system maintains frequency and voltage

More information

SEL-2414 Transformer Monitor

SEL-2414 Transformer Monitor SEL-2414 Transformer Monitor SEL-2414 Base Unit Vertical Chassis Front Panel Large LCD Display 4 Programmable Pushbuttons w/leds 7 Programmable LEDs Operator Control Interface EIA-232 Port Processor and

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

SEL-2440 Discrete Programmable Automation Controller

SEL-2440 Discrete Programmable Automation Controller Discrete Programmable Automation Controller Complete System for Control and Monitoring Rack Panel Surface DIN Rail 32 Inputs 16 Outputs 4 Ports (Standard) Major Features and Benefits Fast and Powerful

More information

SEL-700G Family of Generator and Intertie Protection Relays

SEL-700G Family of Generator and Intertie Protection Relays SEL-700G Family of Generator and Intertie Protection Relays Basic to Comprehensive Protection Intertie Protection Basic Dual-Feeder Overcurrent Protection SEL-700G0, SEL-700G1 SEL-700GT SEL-700GW Small,

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

SEL Real-Time Automation Controller (RTAC)

SEL Real-Time Automation Controller (RTAC) SEL Real-Time Automation Controller (RTAC) Product Family Rugged, deterministic, and reliable automation controllers for any environment 1 ms deterministic processing intervals support critical protection

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided

More information

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS Pole-Top/Pad Mount Digital Voltage Regulator Control, for metering, monitoring, and operational control for step-voltage Regulators shall

More information

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs RELAYABLE POWER AQ 200 series protection, control, measurement and monitoring IEDs Contents AQ 200 series protection and control IEDs 3 AQ 200 benefits 3 AQ 200 protection functions 4 AQ 200 control and

More information

Built for speed, security, and simplicity

Built for speed, security, and simplicity Time-Domain Line Protection Built for speed, security, and simplicity Traveling-wave-based and incremental-quantity-based line protection schemes as fast as ms with traditional pilot channels and over

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

PGC 4000v2 POWER GENERATION CONTROLLER

PGC 4000v2 POWER GENERATION CONTROLLER PGC 4000v2 POWER GENERATION CONTROLLER THOMSON POWER SYSTEM PGC 4000v2 OFFERS THE FOLLOWING: Superior control & monitoring system for Thomson Power Systems advanced Series 2400 Switchgear (refer to separate

More information

Generator Management Relay COMMUNICATIONS GUIDE

Generator Management Relay COMMUNICATIONS GUIDE Title Page g GE Industrial Systems 489 Generator Management Relay COMMUNICATIONS GUIDE Software Revision: 3.00 GE Publication Code: GEK-106495A Part Number: 1601-0149-A2 Copyright 2004 215 Anderson Avenue,

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45 Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, 2 x RJ-45 Main Range of product Product or component type Relay application Configuration type (Cortec) [Us] rated supply voltage

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays Maximize protection Sepam series 10, 20, 40, 60, 80 Modular range of digital protection relays Fast Dependable Simple Increase energy availability 100% available energy Fast response Maximum dependability

More information

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW SEL Distribution Substation Protection and Automation System Protection, Monitoring, and Control System for Distribution Substations Data Sheet SYSTEM ONE-LINE RELAY TARGETS ALARM HISTORY SYSTEM COMM.

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW The Customer Generator applicant ("Applicant") hereby makes application to the T &

More information

M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS

M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS Pole-Top/Pad Mount Digital Tapchanger Control, for metering, monitoring, and operational control of step-voltage load tapchangers shall be provided

More information

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

TWO-WINDING TRANSFORMER DIFFERENTIAL

TWO-WINDING TRANSFORMER DIFFERENTIAL E3-TR PROTECTION WITH AUTOMATIC VOLTAGE Because of the control, measuring and monitoring functions implemented, the IED can also be used as a bay control unit. The EuroCAP configuration tool, which is

More information

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System SYNCHRONIZING M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System Adapts M-4272 Digital Motor Bus Transfer System as a replacement for existing analog motor bus transfer equipment Provides

More information

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay 7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay Document Release History This document is issue 2010/06. The list of revisions up to and including this issue is: 2010/06 Additional

More information

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay Protective Relays Electrical Apparatus ixp-420 Transformer Protection Relay 165-420 Figure 1: Edison Idea Relay The ixp-420 is a member of Cooper Power Systems Edison Idea line of protective relays. The

More information

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic

More information

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5

SPECIFIC INTERCONNECTION PROTECTION REQUIREMENTS... 5 Central Hudson Gas & Electric Corporation (CHG&E) Interconnection Protection Requirements for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System

More information

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport,

More information

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays PROTECTION MiCOM P124 Self and Dual Powered Overcurrent Relays MiCOM P124 are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can

More information

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2)

USB Interface. Power Supply. Manual Raise/Lower Operators. Communications Port (Port 1) Communications Port (Port 2) SEL-2431 Single-Phase Voltage Regulator Control, Two 120 Vac Voltage Inputs, Eight Contact Inputs (Two 120 Vac Programmable, Four 12 Vdc Self-Whetted Programmable, and Two Dedicated), Seven Contact Outputs

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box INTRODUCTION The PL-50 MO units are available in the next mechanical version: The PL-50 MO and PM-250 families represent the different solutions that Team Arteche offers for motor protection. Both families

More information

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs RELAYABLE POWER AQ 200 series protection, control, measurement and monitoring IEDs Contents AQ 200 series protection and control IEDs 3 AQ 200 benefits 3 AQ 200 protection functions 4 AQ 200 control and

More information

SEL-387E Current Differential and Voltage Protection Relay

SEL-387E Current Differential and Voltage Protection Relay SEL-387E Current Differential and Voltage Protection Relay Versatile Solution for Power Apparatus Protection Major Features and Benefits The SEL-387E Relay includes three-phase voltage inputs for metering,

More information

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Product Sheet ECO. Types ECG, AMF Technical data.  product sheet eco ecg-amf - technical data gb v1.0.docx ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side

More information

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs .3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.

More information

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication GE Grid Solutions DS Agile C264 Dual-bay Modular Substation Controller The DS Agile C264 substation controller is a sophisticated solution supporting multiple applications and functions for substation

More information

Numerical Protective and Management Relays

Numerical Protective and Management Relays Numerical Protective and Management Relays Presented at: The Institution of Engineers (India) Andaman and Nicobar State Centre Port Blair Dr. H. K. Verma Deputy Director and Professor of Electrical Engineering

More information

* A8* GE Grid Solutions. Generator Management Relay COMMUNICATIONS GUIDE

* A8* GE Grid Solutions. Generator Management Relay COMMUNICATIONS GUIDE GE Grid Solutions 489 Generator Management Relay COMMUNICATIONS GUIDE Software Revision: 4.0x GE Publication Code: GEK-106495H GE Multilin Part Number: 1601-0149-A8 Copyright 2017 GE Multilin Inc. GE Grid

More information

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification

More information

SEL-487B Bus Differential Relay

SEL-487B Bus Differential Relay Bus Differential Relay Busbar and Breaker Failure Protection, Automation, and Control System Major Features and Benefits The Relay provides bus current differential protection, circuit breaker failure

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

Providing the missing piece in your Condition Based Monitoring platform

Providing the missing piece in your Condition Based Monitoring platform QUALITROL Transformer Monitoring System Providing the missing piece in your Condition Based Monitoring platform Modular design; full customization of monitoring parameters to meet specification Reduce

More information

Distributed Power System SA3100 Drive Configuration and Programming

Distributed Power System SA3100 Drive Configuration and Programming Distributed Power System SA3100 Drive Configuration and Programming Instruction Manual S-3056-1 Throughout this manual, the following notes are used to alert you to safety considerations:! ATTENTION: Identifies

More information

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW. CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS

More information

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control SEL-3505/3505-3 Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control RTAC versatility facilitates easy event collection, protocol conversion, and secure

More information

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination

More information

CONTROLS. Digital Regulator. Digital Regulator Control for General Electric, Siemens, Cooper and Howard Regulators

CONTROLS. Digital Regulator. Digital Regulator Control for General Electric, Siemens, Cooper and Howard Regulators CONTROLS Digital Regulator Control ol M-6200 Digital Regulator Control for General Electric, Siemens, Cooper and Howard Regulators Features Adjustable Bandcenter Adjustable Bandwidth Line Drop Compensation,

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

EDR-3000 Eaton Distribution Relay

EDR-3000 Eaton Distribution Relay EDR-3000 Eaton Distribution Relay Technical Data New Information Description Page 1. General Description.......................... 2 2. Applications............................... 2 3. Drilling Pattern.............................

More information

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter Product data sheet Characteristics ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter Main Range of product Altivar 61 Product or component type Product specific application Component

More information

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform Modular Real-Time Automation Controller Dependable control for harsh environments in a fully integrated, flexible platform Real-Time Automation Controller (RTAC) provides high-speed, deterministic control

More information

Perfect protection smallest space

Perfect protection smallest space www.siemens.com/energy/protection Perfect protection smallest space The SIPROTEC Compact device range redefines protection technology Answers for energy. SIPROTEC Compact is the ideal solution for almost

More information

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756407 E Slide 1 Content REF615 Technical Presentation highlights May 13,

More information

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9 PJM Manual 07: PJM Protection Standards Revision: 3 Effective Date: May 24, 2018 Prepared by System Planning Division Transmission Planning Department PJM 2018 Table of Contents Table of Contents Approval...6

More information

S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication

S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s. automation, control & communication S o m e t h i n g b e t t e r t h a n p r o t e c t i v e r e l a y s IEDs with embedded protection, measurement, automation, control & communication digital processing multifunction Monitoring and metering

More information

MiCOM P521. Fast feeder differential protection

MiCOM P521. Fast feeder differential protection 01 Fast feeder differential protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information