1 IP Sensor IPS2222 User manual Output LED indicators Power input 12VDC adapter 2 Relay outputs LED Indicators 1 wire 2 Dry 2 Analog Green : Power Yellow: Link temperature & humidity contact inputs inputs sensor input I P S U s e r M a n u a l v 1. 6 P a g e 1

2 Benefits and Features. IPS2222 is a device with build on Ethernet web server with 2 digital inputs, 2 analog inputs, 2 relay outputs, 1-Wire input for up to 2 temperature & humidity sensors. Device can be controlled and monitored over any IP network and Internet by web browser or any specialized monitoring software by SNMP v1 and v2 protocol. Benefits Easy and fast configuration full configuration can be performed through the Web using a web browser Control and configuration over TCP/IP and SNMP IP security access to the IPS2222 is protected by name and password 2 digital inputs with dry contact mode (volt free) 2 analog inputs 2 relays with NO contacts 1-Wire input for 2 Temperature & humidity sensors Alarm alert SNMP trap and XML (over HTTP) SNTP synchronization protocol Firmware update over IP Peer-to-Peer mode I P S U s e r M a n u a l v 1. 6 P a g e 2

3 Technical Features Power supply 12VDC / 0.5 A (adapter) Jack Ø5.5 x 2.0 / 10mm Network standards: IEEE 802.3, 10 Mbit/s Network connection: RJ 45 10BASE-T / 10 Mbps Network protocol TCP/IP and HTTP Operating conditions: -20 to +70 C 2 analog inputs - 0 to 60 V DC 2 Relay outputs 3A /24V DC/30V DC 1 sensor input RJ11 for connecting 1-Wire temperature & humidity sensors Aluminium enclosure Dimensions 112 x 82 x 40 [mm] / wall mount Device Connection Connect the IPS2222 to the 10 Mbit or 10/100 Mbit network. Use a classic TP patch cable for connection to switch, router or to PC. If the Ethernet connection is OK, the POWER and LINK indicator should light up and then LINK indicator blink according to network data transfer. I P S U s e r M a n u a l v 1. 6 P a g e 3

4 Restoring defaults factory configuration Press and hold the Reset button located on the back of the box, connect power, and hold the button pressed for 10 seconds or more. Reset Button Default network parameters configuration: IP address: Network mask: Default gateway: IP configuration via DHCP: Disabled User name: admin Password: admin I P S U s e r M a n u a l v 1. 6 P a g e 4

5 Installation Guidelines IPS2222 controller must be installed by qualified personnel. Controller must not be installed directly outdoors. IPS2222 must not be used for medical, life saving purposes, or for any purpose where its failure could cause serious injury or the loss of life. This unit must not be used in any way where it's function or failure could cause significant loss or property damage. The first step is to establish communication between computer and IPS2222 controller. This can be done by assigning a temporary IP address to the computer. For computers with Windows OS assigning of IP address is made in Local area connection properties or Wireless Network Connection Properties. I P S U s e r M a n u a l v 1. 6 P a g e 5

6 IP Address of the computer should be at the same network. Into the web browser you should type If network settings are correct the login page will appear. Free software for Windows PC Ethernet Device Discoverer can be downloaded from to easily found IPS2222 controllers connected to LAN. I P S U s e r M a n u a l v 1. 6 P a g e 6

7 Web Pages Login Page - access to the IPS2222 is protected by name and password Status Page - Monitoring parameters Action when alarm is activated Alarm threshold I P S U s e r M a n u a l v 1. 6 P a g e 7

8 Status page has 4 sections Digital inputs, Analog inputs, Outputs and Sensors. Digital Inputs section can be used for monitoring sensors in dry contact (volt free) mode - motion PIR sensors, Water Leak sensors, Water level sensors, Door/window sensors, Smoke detectors. One side of the sensor is connected to IN1 or IN2 terminal and the other is connected to GND terminal. Please note that Digital inputs are not galvanic isolated! Analog Inputs section can be used for monitoring directly batteries, power supplies, solar panels and any analog sensor with voltage up to 60V DC. Please note that Analog inputs are not galvanic isolated! Outputs section can be used to open/close garage door and control motors, pumps, valves, lights For loads greater than 3A/30V DC an external relay should be used. Sensors section can be used for control 2x1-wire sensors for temperature and humidity Maximum cable length when is used UTP cable is 50m. I P S U s e r M a n u a l v 1. 6 P a g e 8

9 Network Settings page configuration of network parameters MAC address hardware address of the device. After a change, device will be reboot automatically and redirect to the index page. IP address software address of the device. After a change, device will be reboot automatically and you must search it on the new IP address. Enable DHCP - allows device automatically obtain a valid IP address from Gateway Gateway default gateway IP address Subnet mask local network mask Primary DNS needs to be set properly for correct operation. Domain Name Service associates host names with IP addresses. Without a correctly configured DNS server, the following functions will not work: - Time synchronization (SNTP), used in s and SNMP traps - E- mailing (SMTP) HTTP Port The TCP port used for HTTP communications with IPS2222. Default settings for this port is 80. Value of HTTP port can be changed from 80 to I P S U s e r M a n u a l v 1. 6 P a g e 9

10 For example if default port is changed to port 1560 then HTTP request must be System Settings Device name used to identify device on the network NTP server host name of the NTP server to synchronize the time with. Time zone offset of your timezone with respect to that of the NTP Server. If the time is not set the device attempts to synchronize the time approximately once per hour until successful. Current Date - it is necessary to send s. Current Time it is necessary to send s. The time updates on every minute. To refresh the time it is necessary to set Save button. Temperature units - Specifies the unit of temperature (C Celsius / centigrade, F Fahrenheit) I P S U s e r M a n u a l v 1. 6 P a g e 10

11 Account Settings - One user account with username and password can be configured for HTTP access. Sensors Settings Name name of the sensor up to 15 chars ( e.g. like Indoor ) ID unique number for each sensor Measured value the value that sensor is reading. I P S U s e r M a n u a l v 1. 6 P a g e 11

12 Lower range - value below this range are considered to be incorrect and alarm event occurs Upper range - value above this range are considered to be incorrect and alarm event occurs Hysteresis hysteresis is used to avoid multiple alarms when the measured quantity fluctuate. Trap device send a SNMP Trap when alarm event occurs and this option is checked - device send an when alrm event occurs and this option is checked After connecting new sensors or changing RJ11 connections, detect sensors again. I P S U s e r M a n u a l v 1. 6 P a g e 12

13 SNMP Settings The Simple Network Management Protocol - SNMP, is a commonly used service that provides network management and monitoring capabilities. SNMP offers the capability to poll network device and monitor data. SNMP is also capable changing the configurations on the host, allowing the remote management of the network device. The protocol uses a community string for authentication from the SNMP client to the SNMP agent on the managed device. The SNMP Settings page allows you to configure the settings for communication with the device using the SNMP protocol v2.0. SNMP settings SNMP - Enable / Disable communication by SNMP SNMP Port communication port for SNMP protocol. Default port is 161. Write Community - The community is authorized to write values to variables over SNMP. The default write community string is private. I P S U s e r M a n u a l v 1. 6 P a g e 13

14 Read Community - The community is authorized to read values to variables over SNMP. The default read community string is public. Trap settings Trap - Enable / Disable sending trap messages Trap IP address IP address of the trap destination Trap community default trap community is public Trap interval time interval for trap messages in seconds. Min interval = 5 sec. Traps are sent in following conditions: - dry contact inputs change their status - measured voltages on analog inputs goes outside the range - measured temperature or humidity goes outside the range For management and control by SNMP is necessary to use MIB file. MIB file you can download from our website IPS2222 SNMP parameters can be controlled with any SNMP compatible program. To obtain a valid OID number it is necessary to replace the x symbol with product OID Name Access Description Syntax X name read-only Device name String X version read-only Firmware version String setup -> sensors -> sensor1 OID Name Access Description Syntax X sens1id read-only Sensor 1 ID String X sensor1name read-only Sensor 1 description String X temp1lower read-write Temperature lower range Integer X temp1upper read-write Temperature upper range Integer X temp1hyst read-write Temperature hysteresis Integer X temp1 read-write Temperature enable Integer{no(0), yes(1)} I P S U s e r M a n u a l v 1. 6 P a g e 14

15 X temp1trap read-write Temperature trap enable Integer{no(0), yes(1)} X humi1lower read-write Humidity lower range Integer X humi1upper read-write Humidity lower range Integer X humi1hyst read-write Humidity hysteresis Integer X humi1 read-write Humidity enable Integer{no(0), yes(1)} X humi1trap read-write Humidity trap enable Integer{no(0), yes(1)} setup -> sensors -> sensor2 OID Name Access Description Syntax X sens2id read-only Sensor 2 ID String X sensor2name read-only Sensor 2 description String X temp2lower read-write Temperature lower range Integer X temp2upper read-write Temperature upper range Integer X temp2hyst read-write Temperature hysteresis Integer X temp2 read-write Temperature enable Integer{no(0), yes(1)} X temp2trap read-write Temperature trap enable Integer{no(0), yes(1)} X humi2lower read-write Humidity lower range Integer X humi2upper read-write Humidity lower range Integer X humi2hyst read-write Humidity hysteresis Integer X humi2 read-write Humidity enable Integer{no(0), yes(1)} X humi2trap read-write Humidity trap enable Integer{no(0), yes(1)} setup -> sensors OID Name Access Description Syntax Integer{ X tempunit read-write Temperature sensors unit celcius(0), fahrenheit(1)} I P S U s e r M a n u a l v 1. 6 P a g e 15

16 setup -> digitals -> diginput1 OID Name Access Description Syntax X input1name read-write Digital input 1 name String X input1alarmstate read-write Digital input 1 alarm state Integer X input1trapenable read-write Digital input 1 trap enable Integer{no(0), yes(1)} X input1mailenable read-write Digital input 1 enable Integer{no(0), yes(1)} setup -> digitals -> diginput2 OID Name Access Description Syntax X Input2Name read-write Digital input 2 name String X Input2AlarmState read-write Digital input 2 alarm state Integer X Input2TrapEnable read-write Digital input 2 trap enable Integer{no(0), yes(1)} X Input2MailEnable read-write Digital input 2 enable Integer{no(0), yes(1)} setup -> outputs -> output1 OID Name Access Description Syntax X out1name read-write Relay 1 name String X out1control read-write Relay 1 setup control Integer { manual(0), drycontactinput(1), drycontactinput(2), analoginput1(3), analoginput2(4), sens1temp(5), sens1hum(6), sens2temp(7), sens2hum(8), allsensors(9)} I P S U s e r M a n u a l v 1. 6 P a g e 16

17 setup -> outputs -> output2 OID Name Access Description Syntax X out2name read-write Relay 2 name String X out2control read-write Relay 2 setup control Integer { manual(0), drycontactinput(1), drycontactinput(2), analoginput1(3), analoginput2(4), sens1temp(5), sens1hum(6), sens2temp(7), sens2hum(8), allsensors(9)} setup -> analogs -> aninput1 OID Name Access Description Syntax X analog1name read-write Analog input 1 name String X analog1lower read-write Analog input 1 lower range Integer X analog1upper read-write Analog input 1 upper range Integer X analog1hyst read-write Analog input 1 hysteresis Integer X analog1 read-write Analog input 1 enable Integer{no(0), yes(1)} X analog1trap read-write Analog input 1 trap enable Integer{no(0), yes(1)} setup -> analogs -> aninput2 OID Name Access Description Syntax X Analog2Name read-write Analog input 2 name String X Analog2Lower read-write Analog input 2 lower range Integer X Analog2Upper read-write Analog input 2 upper range Integer X Analog2Hyst read-write Analog input 2 hysteresis Integer X Analog2 read-write Analog input 2 enable Integer X Analog2Trap read-write Analog input 2 trap enable Integer I P S U s e r M a n u a l v 1. 6 P a g e 17

18 setup OID Name Access Description Syntax X configsaved read-write Configuration save Integer control OID Name Access Description Syntax X output1 read-write Relay 1 output Integer X output2 read-write Relay 2 output Integer X drycontactinput1 read-only Dry contact input 1 Integer X drycontactinput2 read-only Dry contact input 2 Integer X volt1 read-only Analog input 1 Integer X volt2 read-only Analog input 2 Integer X temperature1 read-only Sensor 1 temperature Integer X humidity1 read-only Sensor 1 humidity Integer X temperature2 read-only Sensor 2 temperature Integer X humidity2 read-only Sensor 2 humidity Integer deviceinfo OID Name Access Description Syntax X devicemacaddress read-only Device MAC Address String I P S U s e r M a n u a l v 1. 6 P a g e 18

19 HTTP API commands and XML status of IPS2222 The relays can be controled by HTTP commands. Before that is required basic authentication. HTTP command device_ip_address /status.xml?r1=1 device_ip_address /status.xml?r1=0 device_ip_address /status.xml?r2=1 device_ip_address /status.xml?r2=0 device_ip_address /status.xml?tg1=1 device_ip_address /status.xml?tg2=1 Description Relay 1 = ON Relay 1 = OFF Relay 2 = ON Relay 2 = OFF Toggle Relay 1 state Toggle Relay 2 state device_ip_address /status.xml?p1=1 Pulse Relay 1 device_ip_address /status.xml?p2=1 Pulse Relay 2 Any application can easily read current values from status.xml tags. File is located at <response> <Device>IPS2222</Device> <HostName>OFFICE</HostName> <MAC>00:04:A3:00:00:A0</MAC> <din1> <In1_name>Input 1</In1_name> <In1_val>OPEN</In1_val> <In1_alarm>0</In1_alarm> </din1> <din2> <In2_name>Input 2</In2_name> <In2_val>OPEN</In2_val> <In2_alarm>0</In2_alarm> </din2> <ain1> <ain1_name>analog 1</aIn1_name> <ain1_val>30.02 VDC</aIn1_val> <ain1_alarm>0</ain1_alarm> </ain1> <ain2> <ain2_name>analog 2</aIn2_name> <ain2_val>30.02 VDC</aIn2_val> <ain2_alarm>0</ain2_alarm> </ain2> I P S U s e r M a n u a l v 1. 6 P a g e 19

20 <Out1> <Out1_name>Garage door 1</Out1_name> <Out1_val>ON</Out1_val> <Out1_pw>3</Out1_pw> <Out1_contr>Manual</Out1_contr> </Out1> <Out2> <Out2_name>Room humidity</out2_name> <Out2_val>ON</Out2_val> <Out2_pw>3</Out2_pw> <Out2_contr>Manual</Out2_contr> </Out2> <S1> <S1_name>Garage</S1_name> <S1_id> AF85</S1_id> <S1T_val>12.3</S1T_val> <S1T_unit> C</S1T_unit> <S1T_alarm>0</S1T_alarm> <S1H_val>---</S1H_val> <S1H_alarm>0</S1H_alarm> <S1_st>1</S1_st> </S1> <S2> <S2_name>Guest Room</S2_name> <S2_id>F </S2_id> <S2T_val>22.1</S2T_val> <S2T_unit> C</S2T_unit> <S2T_alarm>0</S2T_alarm> <S2H_val>48.2</S2H_val> <S2H_alarm>0</S2H_alarm> <S2_st>1</S2_st> </S2> </response> I P S U s e r M a n u a l v 1. 6 P a g e 20

21 Settings Mail server custom or dedicated ip-sens.com. If you not have a mail server on your network then we provide service for free use of the dedicated mail server from ipsens.com. The service from our server is free and not guaranteed! Mail Server Address Host name or IP address of the SMTP server Authentication if necessary use name and password for Mail server Port This controls the port for which outgoing mail connections will be accepted. SMTP uses TCP port 25 or 587. SSL and TLS are not supported. I P S U s e r M a n u a l v 1. 6 P a g e 21

22 Inputs / Outputs Settings Name - In this field you can enter the description of the corresponding parameter for up to 15 characters Digital inputs used for direct connection of volt-free contacts. One side of the contact is connected to Input1 or Input2 and the other side is connected to terminal in the middle GND. User can choose and type own name on the Low and High levels. Also I P S U s e r M a n u a l v 1. 6 P a g e 22

23 user can choose which type of alarm to be activated Trap or or both alarms. Digital inputs are not galvanic isolated! Analog inputs - used for measuring DC voltages. Before using alarm alerts need to set values in the fields Lower Range and Upper Range. Parameters Units, Multiplier and Offset can be used to convert measured voltage from any sensor to meaningful engineering values. Analog inputs are not galvanic isolated! To avoid numerous false alerts (by or SNMP Trap) whenever the reading fluctuates around the threshold, you can use Hysteresis value. Local Relay Outpus settings can select whether the local relay to be activated manually by click button ON/OFF or automatic by any of the following parameters or by all sensors: - Dry contact input 1 - Dry contact input 2 - Analog input 1 - Analog input 2 - Sensor 1 Temperature - Sensor 1 Humidity - Sensor 2 Temperature - Sensor 2 Humidity - All Sensors I P S U s e r M a n u a l v 1. 6 P a g e 23

24 For every Relay control can be set different time for Pulse duration. The resolution is 1 second. By default both relays are activated manualy by web interface of Status page. Remote Relay Outpus settings are used to set controller in Peer-to-Peer mode When an alarm -> normal or normal -> alarm condition occurs on the sensors connected to the inputs of a controller IPS2222, it send an encrypted command to set the relays of another controller IPS2222, located in the same LAN (by IP address) or somewhere on the Internet (by HTTP address). Another option is when manually triggering the local relays of a controller IPS2222 automativally to trigger the relays of the another controller IPS2222. Remote relays control can also be bidirectional - two controllers can control each other's relays. Only one parameter can be assigned for relay activation, at the same time. When the relay is triggered automatically by a parameter then button for manual operation on the Status page hides. For loads greater than 3A/30V DC an external relay should be used. I P S U s e r M a n u a l v 1. 6 P a g e 24

25 Firmware update In this page you can update IPS2222 with the new firmware. Please keep in mind not to power off the device during the update! It can damage the device! I P S U s e r M a n u a l v 1. 6 P a g e 25

26 Application Examples - Remote monitoring application I P S U s e r M a n u a l v 1. 6 P a g e 26

27 I P S U s e r M a n u a l v 1. 6 P a g e 27

28 - Control of 220V AC / 20 A motor using external relay - Automatic stop water supply to the dishwasher at the detection of water leakage I P S U s e r M a n u a l v 1. 6 P a g e 28

29 - Opening and monitoring Garage Doors - Peer-to-Peer mode for remote relay control I P S U s e r M a n u a l v 1. 6 P a g e 29

30 Mechanical dimmensions Bottom view I P S U s e r M a n u a l v 1. 6 P a g e 30

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

Connector for sensing cable

Connector for sensing cable HWg-WLD MANUAL ETHERNET 10/100 Mbps Status LED Yellow: Power & Mode Green: Link & Activity Connection cable 100 m max POWER input 5V DC supply Use the supplied power adapter SENSOR Connector for sensing

More information

LAN Interface TCW120B

LAN Interface TCW120B LAN Interface TCW120B 1. Short description TCW120 is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based networks and

More information

Ethernet controller TCW121B User manual

Ethernet controller TCW121B User manual Ethernet controller TCW121B User manual 1. Short description TCW121B is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based

More information

3. Technical parameters

3. Technical parameters 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. The device can be used stand-alone or as

More information

Ethernet controller TCW180B Users manual

Ethernet controller TCW180B Users manual Ethernet controller TCW180B Users manual 1. Short description TCW180B is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. This

More information

Ethernet controller TCW180 Users manual

Ethernet controller TCW180 Users manual Ethernet controller TCW180 Users manual 1. Short description TCW180 is 8-Channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. This

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

Ethernet controller TCW112-CM Users manual

Ethernet controller TCW112-CM Users manual Ethernet controller TCW112-CM Users manual 1. Short description TCW112-CM is an Ethernet controller, which is designed to work in IP-based networks. It has 1 digital and 1 analog input, 1-Wire interface

More information

Ethernet controller TCW120 Users manual

Ethernet controller TCW120 Users manual Ethernet controller TCW120 Users manual 1. Short description TCW120 is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based

More information

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

EthernetcontrollerTCW111 Users manual

EthernetcontrollerTCW111 Users manual EthernetcontrollerTCW111 Users manual 1. Short description TCW111 is an Ethernet based controller, which is designed to work in IP-based networks. Its functionality allows solving a range of tasks that

More information

smartden IP-WatchDog PING Restarter and Auto-Rebooter

smartden IP-WatchDog PING Restarter and Auto-Rebooter smartden IP-WatchDog PING Restarter and Auto-Rebooter User Manual Date: For firmware version: v1.21 / May 2017-1- Content smartden IP-WatchDog User Manual 1. Features... 3 2. Application examples... 4

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL HWg-STE connections LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors. - Max. distance with 1

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 4002 MANUAL www.hw-group.com 2 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 3266 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied

More information

Ethernet controller TCW110 Users manual

Ethernet controller TCW110 Users manual Ethernet controller TCW110 Users manual 1. Short description TCW110 is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based

More information

VT805 / Monitoring system

VT805 / Monitoring system Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Monitoring system LN-VT325. Environmental Infrastructure monitoring Environmental Infrastructure monitoring Monitoring system LN-VT325 Environmental monitoring of small facilities, access control, monitoring of tempertures, smoke, water leakages, voltages and more. Overview

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring Environmental Infrastructure monitoring VT825 / Environmental Monitoring unit The unit is used for IT environmental control in data-centers, remote facilities, offices, industrial facilities & remote shelters.

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

SmartDEN IP-32IN Web enabled 32 Input Module

SmartDEN IP-32IN Web enabled 32 Input Module SmartDEN IP-32IN Web enabled 32 Input Module User Manual Date: For firmware version: v1.26 / Jan 2018-1- Document Revision History SmartDEN IP-32IN User Manual Version Date Comments 1.00 2016/10/21 Firmware

More information

VT608 / Switched PDU with 8 outlets

VT608 / Switched PDU with 8 outlets Switched PDU with Monitoring VT608 / Switched PDU with 8 outlets Device is used for load management and allows to switch on/off or reboot up to 8 outlets. It has built-in temperature sensor, can connect

More information

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1 Instruction Manual Environmental Monitoring Unit with Optional POE Watchdog 15 Series Firmware Version 1 Geist 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com

More information

1. General Description

1. General Description ipio-2, ipio-8, ipio-16 Monitor and Control of Digital I/O 1. General Description The ipio is a network attached, web enabled digital input and output device. The ipio can be controlled and monitored with

More information

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide BiPAC 5200 Series (802.11g) ADSL2+ Modem/Router Quick Start Guide Billion BiPAC 5200 Series ADSL2+ Modem/Router For more detailed instructions on configuring and using the (802.11g) ADSL2+ Modem/Router,

More information

sensorprobe2 / sensorprobe8 User Manual

sensorprobe2 / sensorprobe8 User Manual www.akcp.com sensorprobe2 / sensorprobe8 User Manual Help Version updated till firmware 382L Copyright 2007, AKCP Co., Ltd.. 1) Introduction 1. What is sensorprobe? 2. What s the difference between sp2

More information

EP2 EP8 User Manual. Copyright 2007,ATAL

EP2 EP8 User Manual. Copyright 2007,ATAL EP2 EP8 User Manual Copyright 2007,ATAL 1) Introduction 1. What is EP? 2. What s the difference between the EP2 and the EP8? 3. How to use this manual 4. EP2 5. EP8 2) Installation 1. Assigning an IP address

More information

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power. Ethernet/Network Communications Module Installation and Programming Manual LINQ2 - Two (2) Port Connectivity Module DOC#: LINQ2 Rev. 060514 More than just power. Overview: Altronix LINQ2 network module

More information

RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL

RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL RAMOS PLUS RACK MONITORING SYSTEM INTRODUCTION MANUAL EN Table of Contents Introduction... 3 What is the RAMOS PLUS and Rack sensor ST3H... 3 RAMOS PLUS Features:... 3 Port assignment information for RAMOS

More information

RLH Industries, Inc. Smart 4 Input Sensor. User Guide U B-0330

RLH Industries, Inc. Smart 4 Input Sensor. User Guide U B-0330 Input Sensor User Guide U-131 018B-0330 ! Copyright 017 All rights reserved. No part of this document may be copied or distributed without permission. The RLH logo may not be used for commercial purposes

More information

BiPAC 7300VP/ 7300VGP

BiPAC 7300VP/ 7300VGP BiPAC 7300VP/ 7300VGP VoIP/(802.11g) ADSL2+ Router Quick Start Guide Billion BiPAC 7300VGP Series ADSL2+ Router For more detailed instructions on configuring and using the VoIP/802.11g ADSL2+ Router,

More information

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending

ILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending ILF-100WD User Manual Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending Rev. 1.17 02/24/2009 Table of Contents Installation and Configuration...3 Network Configuration...4

More information

Expert Power Control NET 4x DIN

Expert Power Control NET 4x DIN Expert Power Control NET 4x DIN 2009 Gude Analog- & Digitalsysteme GmbH 2009 Gude Analog- & Digitalsysteme GmbH 14.12.2009 Content 3 Table of contents 1 Security Advise 4 2 Description 5 3 Hardware 3.1

More information

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...

More information

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer K01-SNMP004-00 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE...

More information

SmartDEN Notifier Web enabled 32-Inputs Module with MQTT and notifications

SmartDEN Notifier Web enabled 32-Inputs Module with MQTT and  notifications SmartDEN Notifier Web enabled 32-Inputs Module with MQTT and e-mail notifications User Manual Date: For firmware version: v1.25 / Oct 2017-1 - Document Revision History SmartDEN Notifier User Manual Version

More information

Ethernet controller TCW240B

Ethernet controller TCW240B Ethernet controller TCW240B 1. Introduction TCW240B is a multi-functional device for monitoring and control in Ethernet based networks. It includes 4 digital inputs, 4 analog inputs, 1-Wire interface for

More information

Installation of the PCMeasure Movement Sensor (30114)

Installation of the PCMeasure Movement Sensor (30114) 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System.

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Operation Manual Table of Contents Description: The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Directory: Overview Pg. 2 Features Pg. 3 Quick Setup Guide Pg. 3 Settings

More information

SmartDEN IP-16R Web enabled 16 Relay Module

SmartDEN IP-16R Web enabled 16 Relay Module SmartDEN IP-16R Web enabled 16 Relay Module User Manual Date: For firmware version: v1.20 / May 2017-1- Content SmartDEN IP-16R User Manual 1. Features... 3 2. Application examples... 4 3. Technical parameters...

More information

smartden IP-Maxi Web enabled IP Controller User Manual Date: 09 March 2018 For firmware version: v1.24 / March

smartden IP-Maxi Web enabled IP Controller User Manual Date: 09 March 2018 For firmware version: v1.24 / March smartden IP-Maxi Web enabled IP Controller User Manual Date: 09 March 2018 For firmware version: v1.24 / March 2018-1 - Document Revision History Version Date Comments 1.00 2018/03/09 The initial release

More information

BiPAC 7300(G) (802.11g) ADSL2+ Router. Quick Start Guide

BiPAC 7300(G) (802.11g) ADSL2+ Router. Quick Start Guide BiPAC 7300(G) (802.11g) ADSL2+ Router Quick Start Guide Billion BiPAC 7300(G) ADSL2+ Router For more detailed instructions on configuring and using the (802.11g) ADSL2+ Router, please refer to the on-line

More information

Climate Guard. Installation and Operation Manual

Climate Guard. Installation and Operation Manual Climate Guard Installation and Operation Manual TABLE OF CONTENTS Introduction...1 Welcome...1 Unpacking...1 Hardware Overview...1 Web Interface Overview...3 Default Settings...9 Getting Help...9 Installation...10

More information

BiPAC 6404VP/VGP. VoIP/(802.11g) Broadband Firewall Router. Quick Start Guide

BiPAC 6404VP/VGP. VoIP/(802.11g) Broadband Firewall Router. Quick Start Guide BiPAC 6404VP/VGP VoIP/(802.11g) Broadband Firewall Router Quick Start Guide VoIP/(802.11g) Broadband Firewall Router For more detailed instructions on configuring and using the VoIP/(802.11g) Broadband

More information

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s PCE-IMS 1 IP Monitoring systems IP Switchable Metered PDU s System installation System setting Accessories Monitoring master unit Extension units Sensors SNMP server List of USB-cameras - 02 - Contents

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

User manual NANO TEMPERATURE SENSOR

User manual NANO TEMPERATURE SENSOR User manual NANO TEMPERATURE SENSOR Soft >= 1.1 Dear Customer! INVEO s.c. ul. Rzemieślnicza 21 43-340 Kozy tel: +48 33 444 65 87 www.inveo.com.pl info@inveo.com.pl Thank you very much for choosing our

More information

BTRM200 Battery Test Remote Monitor. User Guide

BTRM200 Battery Test Remote Monitor. User Guide BTRM200 Battery Test Remote Monitor User Guide Contact : Ventev Wireless Infrastructure 11126 McCormick Road Hunt Valley, MD 21031 Phone Number 800.851.4965 Email Sales@ventev.com Ventev Wireless Infrastructure

More information

Managing Standalone EAP

Managing Standalone EAP CHAPTERS 1. Manage System Logs 2. Configure Web Server 3. Configure Management Access 4. Configure Trunk (For EAP330) 5. Configure LED 6. Configure PoE (For EAP225-Wall) 7. Configure SSH 8. Configure Management

More information

EC-11 Ethernet Converter

EC-11 Ethernet Converter EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. VT800 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all VT or SC sensors, it provides a complete environmental,

More information

BIPAC-5100 / 5100W (Wireless) ADSL Router

BIPAC-5100 / 5100W (Wireless) ADSL Router BIPAC-5100 / 5100W (Wireless) ADSL Router Quick Start Guide Billion BIPAC-5100 / 5100W ADSL Router For more detailed instructions on configuring and using the (Wireless) ADSL Firewall Router, please refer

More information

Table Of Contents. 1. Introduction... 1

Table Of Contents. 1. Introduction... 1 User Manual Table of Content Table Of Contents 1. Introduction... 1 1.1 Brief Introduction to Web Interfaces... 1 1.2 How to Log In... 1 1.3 General Setting... 2 1.3.1 Date and Time Setting... 2 1.3.2

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information

Instruction Manual Environmental Monitoring Unit with Output Relays. Watchdog 1400 Series Firmware Version 3

Instruction Manual Environmental Monitoring Unit with Output Relays. Watchdog 1400 Series Firmware Version 3 Instruction Manual Environmental Monitoring Unit with Output Relays Watchdog 1400 Series Firmware Version 3 Contents Contents... 2 Specifications... 3 Overview 3 Environmental 3 Electrical 3 Output Relay

More information

Zavio P5111/ P5116/ P5210 Quick Installation Guide

Zavio P5111/ P5116/ P5210 Quick Installation Guide 86085M2000010 Zavio P5111/ P5116/ P5210 Quick Installation Guide Installation Steps Please follow the installation steps below to set up your P5111 / P5116/ P5210 Day/Night Pan/Tilt IP Camera. Check the

More information

RTU32. SNMP Alarm and Control Module for Network Management. User s Manual Operation and Installation Guidelines V / Nov 2015 / Doc

RTU32. SNMP Alarm and Control Module for Network Management. User s Manual Operation and Installation Guidelines V / Nov 2015 / Doc RTU32 SNMP Alarm and Control Module for Network Management User s Manual Operation and Installation Guidelines V. 1.03 / Nov 2015 / Doc 40261 103 Table of contents 1. Introduction... 4 2. RTU32 SNMP Agent

More information

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer Version 1.3 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE... 4

More information

GV-I/O Box 4E. Contents

GV-I/O Box 4E. Contents GV-I/O Box 4E Contents 1.1 Key Features... 2 1.2 System Requirements... 2 1.3 Packing List... 2 1.4 Overview... 3 1.5 Connecting to PC... 4 1.5.1 RS-485 Wiring... 4 1.6 Assigning Device ID to GV-I/O Box

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

VENTEV INNOVATIONS BTRM200 Battery Test Remote Monitoring System User Guide V1.0. Innovations BTRM200. Battery Test Remote Monitor User Guide

VENTEV INNOVATIONS BTRM200 Battery Test Remote Monitoring System User Guide V1.0. Innovations BTRM200. Battery Test Remote Monitor User Guide Innovations BTRM200 Battery Test Remote Monitor User Guide Contact : Ventev Innovations 10999 McCormick Road Hunt Valley, MD 21031 Phone Number 800.759.9996 Email Info@ventev.com 1 Contents 1. 2. 3. 4.

More information

User Manual. For H.264 Cameras. Version 2.0.0

User Manual. For H.264 Cameras. Version 2.0.0 User Manual For H.264 Cameras Version 2.0.0 Catalogue Basic Operation... 3 Camera Settings... 3 System... 3 Device Name... 4 Time... 4 User... 4 Network... 5 IP... 5 Port... 5 WiFi... 6 UPnP... 6 DDNS...

More information

ENVIROMUX-MICRO-T(RHP)

ENVIROMUX-MICRO-T(RHP) ENVIROMUX Series ENVIROMUX-MICRO-T(RHP) Micro Environment Monitoring System Installation and Operation Manual Front View of ENVIROMUX-MICRO-TRHP MAN220 Rev Date 11/14/17 TRADEMARK ENVIROMUX is a registered

More information

QUICK-START EMU M-BUS CENTER ENGLISH

QUICK-START EMU M-BUS CENTER ENGLISH QUICK-START EMU M-BUS CENTER ENGLISH EN QUICK-START INSTRUCTIONS CONTENT INSTALLATION...3 Power supply...3 Network connection...4 Connect meter (M-BUS)...4 START-UP PROCEDURE...5 Default network configuration...5

More information

WiFi Edition User Guide Model TM-WIFI330. Rev 2.6 for firmware

WiFi Edition User Guide Model TM-WIFI330. Rev 2.6 for firmware WiFi Edition User Guide Model TM-WIFI330 1 Rev 2.6 for firmware7.00 http://www.temperaturealert.com/ 2013 Temperature@lert User Guide Thank you for choosing Temperature@lert to protect your highly valuable

More information

ETH002-2 Relays at 16A Technical Documentation

ETH002-2 Relays at 16A Technical Documentation ETH002-2 Relays at 16A Technical Documentation Overview The ETH002 provides two volt free contact relay outputs with a current rating of up to 16Am. The module is powered from a 12vdc supply which can

More information

Configuring and Managing the IP Camera

Configuring and Managing the IP Camera CHAPTER 3 The Cisco Video Surveillance IP Camera provides configuration windows that you use to configure and manage the IP camera. This chapter explains how to access the configuration windows, describes

More information

ENVIROMUX-1W Environment Monitoring System with 1-Wire Sensor Interface Installation and Operation Manual

ENVIROMUX-1W Environment Monitoring System with 1-Wire Sensor Interface Installation and Operation Manual ENVIROMUX Series ENVIROMUX-1W Environment Monitoring System with 1-Wire Sensor Interface Installation and Operation Manual Front View of ENVIROMUX-1W MAN253 Rev Date 11/14/17 TRADEMARK ENVIROMUX is a registered

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

EGW1-IA3-MB User s Manual

EGW1-IA3-MB User s Manual www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

SEI DC-UPS Power Management Package Users Manual

SEI DC-UPS Power Management Package Users Manual SEI DC-UPS Power Management Package Users Manual (301) 694-9601 (800) 765-4734 Fax (301) 694-9608 Email: info@seipower.com www.seipower.com 5115 Pegasus Court Suite Q Frederick, MD 21704 1. Introduction

More information

I-Fly Wireless Broadband Router

I-Fly Wireless Broadband Router with 4 Fast Ethernet ports + 1 Wan port Quick Start Guide A02-WR-54G/G2 (November 2003)V1.00 For more detailed instructions on configuring and using the I- Storm Lan Router ADSL, please refer to the online

More information

BC6000. User Manual Operation and Installation Guidelines. SNMP Alarm and Control Module For Network management. V / Sept 2012 / Doc 40261

BC6000. User Manual Operation and Installation Guidelines. SNMP Alarm and Control Module For Network management. V / Sept 2012 / Doc 40261 BC6000 SNMP Alarm and Control Module For Network management User Manual Operation and Installation Guidelines V. 1.02 / Sept 2012 / Doc 40261 Table of Contents 1. Introduction... 4 2. BC6000 SNMP Agent

More information

Power Switch Cabinet 4-Port New Generation

Power Switch Cabinet 4-Port New Generation May 2011 PSE544-XX Power Switch Cabinet 4-Port New Generation SUPPORT FREE technical support This product carries the CE mark to indicate compliance with the European Directive on Electromagnetic Compatibility

More information

NOVUS AUTOMATION 1/92

NOVUS AUTOMATION  1/92 INSTRUCTION MANUAL V1.1x INTRODUCTION... 3 CONNECTIONS AND INSTALLATION... 4 MECHANICAL INSTALLATION... 4 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE HMI... 9 ELECTRICAL CONNECTIONS...

More information

Part I: External Installation Direction

Part I: External Installation Direction Part I: External Installation Direction A. Check the parts in your box CPE SET 1 DC 12V/1.5A Power Adapter 1 PoE DC Injector 1 Hose Clamps 2 Manual & QIG CD 1 Paper QIG 1 B. How to fix the CPE on the Pole

More information

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Temperature Alert. LAN-based Temperature and Humidity Data Logger Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -55 C to +125 C (-67 F to +257 F) Standard

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20 v.100.00x will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke, water leakages, power outages and much more.

More information

INSTRUCTION MANUAL V1. 2x A

INSTRUCTION MANUAL V1. 2x A INSTRUCTION MANUAL V1. 2x A INTRODUCTION... 3 CONNECTIONS AND INSTALLATION... 4 MECHANICAL INSTALLATION... 4 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE HMI... 9 ELECTRICAL

More information

BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide

BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide Billion BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router For more detailed instructions

More information

BiPAC 8501/8521. SHDSL.bis (VPN) Firewall Bridge/Router. Quick Start Guide

BiPAC 8501/8521. SHDSL.bis (VPN) Firewall Bridge/Router. Quick Start Guide BiPAC 8501/8521 SHDSL.bis (VPN) Firewall Bridge/Router Quick Start Guide Quick Start Guide Chapter 1: Introduction 2 Billion BiPAC 8501/8521 SHDSL.bis (VPN) Firewall Bridge/ Router For more detailed instructions

More information

User Manual. ACL Series

User Manual. ACL Series User Manual ACL Series Contents Contents... 2 Introduction... 5 Features... 5 Applicable Models... 6 Specifications... 6 Electrical Ratings... 6 Operating Environment... 6 Dimensions... 6 User Account

More information

ServSensor JR. March 2004 EME102A

ServSensor JR. March 2004 EME102A ServSensor JR March 2004 EME102A CE STATEMENT This product carries the CE mark to indicate compliance with the European Directive on Electromagnetic Compatibility (89/336/EEC). It has been tested to EN55024:1998

More information

UPS COMMUNICATION Web Card

UPS COMMUNICATION Web Card UPS COMMUNICATION Web Card User Manual For Model: SNMP-INTT-01 2 FEATURES Web based access to facilitate easy configuration of the UPS Real Time UPS Monitoring Event and Data Logs Event Notifications via

More information

GSM-GPRS Remote monitoring controller TCG120

GSM-GPRS Remote monitoring controller TCG120 GSM-GPRS Remote monitoring controller TCG120 1. Introduction TCG120 is a GSM-GPRS remote monitoring controller for distributed IO monitoring and control. The controller has 2 digital inputs, 2 analog inputs,

More information

epowerswitch 1G R2 User guide Version

epowerswitch 1G R2 User guide Version epowerswitch 1G R2 User guide Version 02 2011 www.neol.com Copyright by NEOL S.A.S - 4 Rue Nationale, 67800 BISCHHEIM, France Printed in France All rights reserved. No part of this documentation, accompanying

More information

EAP150 EAP150. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

EAP150 EAP150. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW Long Range Ceiling Mount Access Point 2.4 GHz 150Mbps 11b/g/n 26dBm AP/WDS/Repeater PRODUCT OVERVIEW is a 150Mbps wireless-n ceiling mount AP which offers users extended coverage, strong penetration, secure

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

Accessing the AXM-WEB at Admin level

Accessing the AXM-WEB at Admin level Accessing the AXM-WEB at Admin level This document will provide a brief overview of accessing the AXM-WEB at Admin level. In this level users will be able to read and view meter information as well as

More information