INSTRUCTIONS FOR THE IQ DC POWER SUPPLY INSTRUCTION LEAFLET IL E

Size: px
Start display at page:

Download "INSTRUCTIONS FOR THE IQ DC POWER SUPPLY INSTRUCTION LEAFLET IL E"

Transcription

1 INSTRUCTIONS FOR THE IQ DC POWER SUPPLY INSTRUCTION LEAFLET For more information visit: Effective: 7/05

2

3 IQ DC Power Supply Effective Date: 7/05 Page Introduction The IQ DC Power Supply is a dc to ac inverter module intended for operation of ac powered devices from a dc supply. The unit will operate the Eaton Cutler- Hammer MP-3000, URTD or other ac-powered equipment requiring no more than 100 VA of power at any power factor. Output Voltage: sinusoidal wave, 120 Vac 60 Hz /.17 A Continuous (20 VA) THD is less than 5% at full load Operating Temperature Range: -20 C to + 60 C Humidity: 5-95% non-condensing Protection Limits: Average output current is limited to 0.4 A. After an average current overload, unit cools itself and restarts. Complies with ANSI standards. 4.0 Installation This technical document covers most aspects of installation, operation and unit level maintenance of the IQ DC Power Supply. This document is a guide only for authorized and qualified personnel who select and use the IQ DC Power Supply. If you require further information regarding particular installation, application or maintenance activity, contact your Cutler-Hammer representative. These instructions do not cover all details, variations or combinations of the equipments, its storage, delivery, installation, check-out, safe operation or maintenance. Care must be exercised to comply with local, state and national regulations, as well as safety practices for this class of equipment. CAUTION REMOVE ALL POWER FROM THE DEVICE TO WHICH THE IQ DC POWER SUPPLY IS BEING CONNECTED; OTHERWISE, SERIOUS OR FATAL PERSONAL INJURY AND EQUIPMENT DAMAGE MAY RESULT. Figure 1: IQ DC Power Supply 2.0 Features Handles input voltages of 125 Vdc ac output is isolated from the incoming power Input surge protection according to IEC Level 3 (2 kv) Sinusoidal Waveform 3.0 Specifications Supply Voltage: 125 Vdc (.4 A max at full load) Nominal. Operates from 105 to 140 Vdc. Input Isolation: 1.5 k Vdc input to output, input to chassis and output to chassis The IQ DC Power Supply should be fastened securely in place before operating. Locate the module in an area where air can freely move about the unit. While mounting the unit absolutely NO power should be connected. See Figure 2 for mounting holes. 5.0 Wiring See Figure 3 for electrical connections. 1. Note that the unit has no ON-OFF switch identify some external means of removing the dc supply. 2. Connect the ac load to the terminals labeled 115 VAC OUTPUT. Either terminal can be connected to ac common. 3. Connect the dc supply leads to the terminals labeled 125 VDC INPUT. Effective Date: 7/05 For more information visit: Page 1

4 IQ DC Power Supply Page 2 Effective Date: 7/05 Figure 2: Power Supply Drawing 7.0 Warranty and Liability Information NO WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OF MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE ARE MADE RE- GARDING THE INFORMATION, RECOMMENDA- TIONS AND DESCRIPTIONS CONTAINED HEREIN. Figure 3: Terminals 6.0 Operation Dc voltage may be applied to the IQ DC Power Supply by any number of methods. It will start reliably with a 125 Vdc step input from a contractor or with a slow ramp from a dc power source. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information and descriptions contained herein. Page 2 For more information visit: Effective Date: 7/05

5 IQ DC Power Supply Effective Date: 7/05 Page 3 This page is intentionally left blank. Effective Date: 7/05 For more information visit: Page 3

6 Eaton s Electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, worldclass manufacturing methods, and global engineering services and support, Eaton s Electrical business provides customer-driven solutions under brand names such as Cutler-Hammer, Durant, Heinemann, Holec and MEM, which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit Eaton Corporation is a diversified industrial manufacturer with 2003 sales of $8.1 billion. Eaton is a global leader in fluid power systems and services for industrial, mobile and aircraft equipment; electrical systems and components for power quality, distribution and control; automotive engine air management systems and powertrain controls for fuel economy; and intelligent drivetrain systems for fuel economy and safety in trucks. Eaton has 55,000 employees and sells products to customers in more than 100 countries. For more information, visit Eaton Corporation Cutler-Hammer business unit 1000 Cherrington Parkway Moon Township, PA USA / Style # 66A2260H01 For additional information please call: Power Management Application Support option 1 / option Eaton Corporation All Rights Reserved Publication No. July 2005

Eaton Logic Controller. Product Focus

Eaton Logic Controller. Product Focus Eaton Logic Controller Product Focus The Eaton Logic Controller. Compact, modular, and ready to communicate. It s the cost-effective solution to machine control. Eaton Cutler-Hammer s D50 PLC broke new

More information

Time delay undervoltage module

Time delay undervoltage module Supersedes December 2010 Power Defense ICCB Series NRX IZMX Instructions apply to: UL489 IEC UL1066/ANSI : PD-NF, Series NRX NF : PD-NF, IZMX16 : Series NRX NF UL489 : PD-RF IEC : PD-RF, IZMX40 120VAC

More information

Intelligent Technologies (IT.) Starter Network Adapter Products (SNAP) Product Focus D77B-DSNAP D77B-QSNAP

Intelligent Technologies (IT.) Starter Network Adapter Products (SNAP) Product Focus D77B-DSNAP D77B-QSNAP Intelligent Technologies (IT.) Starter Network Adapter Products (SNAP) Product Focus D77B-DSNAP D77B-QSNAP Extending the Communication Capabilities of Electromechanical Starters and Soft Starters 0 1 2

More information

EZ Intelligent Relay. Product Focus

EZ Intelligent Relay. Product Focus EZ Intelligent Relay Product Focus Easy operation with maximum benefits The Eaton EZ intelligent relays provide basic functions that users could only implement previously with individually installed and

More information

Digitrip 520MC with Maintenance Mode

Digitrip 520MC with Maintenance Mode Digitrip 520MC with Maintenance Mode Effective May 2006 I.S 70C1454 Supplement to I.L. 70C1037 FIGURE 1. Digitrip 520MC with ARMs in Magnum Circuit Breaker Table of Contents 1.0 General... 2 2.0 Maintenance

More information

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

for the SPV Installation and Operation Manual Instruction Manual IM E Contents Rev. 3 Contents Description Page 1. Introduction............................ 2 2. Preparation............................ 2 3. Installation Procedures................... 3 4. Ordering Guidelines......................

More information

Intelligent Technologies (IT.) Motor Control Centers Product Focus Designed Specifically for the Power Generation Industry

Intelligent Technologies (IT.) Motor Control Centers Product Focus Designed Specifically for the Power Generation Industry Intelligent Technologies (IT.) Motor Control Centers Product Focus Designed Specifically for the Power Generation Industry Once you know IT., everything changes For the most forward-looking motor control

More information

Series NRX drawout circuit breaker and cassette rejection interlocks

Series NRX drawout circuit breaker and cassette rejection interlocks Series NRX Instructions apply to: UL 1066/ANSI, UL489 series NRX NF frame IEC IZMX16 UL489 series NRX RF frame IEC IZMX40 WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON

More information

epro Canvas epro Canvas TM (Catalog No. CANVAS)

epro Canvas epro Canvas TM (Catalog No. CANVAS) epro Canvas TM (Catalog No. CANVAS) Product Focus Configuration Software for PanelMate epro ES/PS Easy to Use Collaborative Capabilities Innovation with Migration SM epro Canvas Creation Creative Expression

More information

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer Westinghouse Transfer Switch Equipment IQ Transfer Setting a new standard with the most advanced microprocessor-based transfer switch logic available. It s programmable for superior reliability and versatile

More information

Intelligent Technologies

Intelligent Technologies Intelligent Technologies QCPort Starter Network Adapter Product (QSNAP) Installation and User Manual Publication No. MN05001001E New Important Notice Please Read The product discussed in this literature

More information

Cutler-Hammer. Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor TD 17530A

Cutler-Hammer. Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor TD 17530A Cutler-Hammer TD 17530A Instructions for Installation, Operation and Maintenance of Cutler-Hammer IQ Analyzer Electrical Distribution System Monitor TD 17530A Page iii! WARNING! WARNING IMPROPERLY INSTALLING

More information

INCOM communications adapter module

INCOM communications adapter module Instruction Leaflet IL0131124EN Supersedes July 2016 INCOM communications adapter module Power Defense ICCB Instructions apply to: UL489 : PD-NF UL489 : PD-RF IEC : PD-NF, IZMX16 IEC : PD-RF, IZMX40 WARNING

More information

Multi Unit Enclosed Meter

Multi Unit Enclosed Meter Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................

More information

Residential Renovation Loadcenters and Accessories

Residential Renovation Loadcenters and Accessories Residential Renovation Loadcenters and Accessories Product Focus Replaces existing fuse boxes or loadcenters Industry Exclusive Renovation Loadcenter Quick and Clean Installation Designed specifically

More information

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter Contents Description Page Product overview.... 2 Key features.... 2 Wide voltage range.... 2 Ordering information... 2 Additional features.... 2 functions comparison... 3 Metering.... 4 Specifications....

More information

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN Voltage Regulators MN225067EN Effective November 2016 Supersedes June 2014 (S225-70-13) COOPER POWER Input/Output (I/O) module installation instructions SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF

More information

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER

More information

Clink II Integrated Motor Control System

Clink II Integrated Motor Control System link II Integrated Motor ontrol ystem Product ocus Optimising plant performance, efficiency and productivity implex and redundant configuration possible lexibility of communication protocols to higher

More information

Eaton Logic Controller DeviceNet (ELC-CODNET)

Eaton Logic Controller DeviceNet (ELC-CODNET) 3 2 3 2 7 8 7 8 Eaton Logic Controller DeviceNet (ELC-CODNET) Instruction Manual 4 5 6 5 0 0 9 4 6 9 ELC-CODNET Pub. No. MN05003005E For more information visit: www.eatonelectrical.com Company Information

More information

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03 Instructions for ing Magnum DS Trip Units Contents Description Page 1: Introduction............................ 2 2: Kit / Breaker Information.............. 2 3: Kit Setup.......................... 3 4:

More information

E-Series Troubleshooting Guide

E-Series Troubleshooting Guide E-Series Troubleshooting Guide Contents Troubleshooting by means of the System-OK-LED status... 5 Troubleshooting Hardware... 11 Troubleshooting Operation of the Device... 15 Troubleshooting Parameter

More information

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS INSTRUCTION LEAFLET IB17555D_ADDENDUM Effective Date: 11/02

More information

Protection for All Your Appliances and Electronics

Protection for All Your Appliances and Electronics Protection for All Your Appliances and Electronics How Voltage Surges Can Cause Damage in Your Home Our homes are filled with sensitive electronics. These devices are easily damaged by common power surges,

More information

IB E INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER MD-3000 SERIES OF PROTECTIVE RELAYS

IB E INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER MD-3000 SERIES OF PROTECTIVE RELAYS IB02602001E INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER MD-3000 SERIES OF PROTECTIVE RELAYS Effective March 2006 per IQ-10256 Effective March 2006 per IQ-10256 SECTION

More information

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN Deadbreak Apparatus Connectors MN650022EN COOPER POWER Effective March 2016 Supersedes S600-14-1 June 2010 SERIES 600 A U-OP visible break connector system operation instructions DISCLAIMER OF WARRANTIES

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Power Xpert Meter 2000 Series

Power Xpert Meter 2000 Series Quick Start Guide IM02601002E Effective April 2017 PXM 2250 PXM 2260 PXM 2270 PXM 2280 PXM 2290 Power Xpert Meter 2000 Series Contents Description Page Mechanical Installation... 1 Electrical Wiring....

More information

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN Padmounted switchgear MN285011EN Effective May 2017 Supersedes November 2004 (S285-10-4) Visible-Break switch accessory operation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION

More information

Xitanium Outdoor LED Drivers Single Current

Xitanium Outdoor LED Drivers Single Current Xitanium LED driver Datasheet Xitanium Outdoor LED Drivers Single Current LED-based light sources are an excellent solution for outdoor environments. They are long-lasting and require low maintenance.

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

LP800 Loop Tester. Installation and Operation Manual

LP800 Loop Tester. Installation and Operation Manual LP800 Loop Tester Installation and Operation Manual DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on

More information

Digitrip 1150 with Maintenance Mode

Digitrip 1150 with Maintenance Mode Digitrip 1150 with Maintenance Mode Effective July 2006 I.S. 70C1486 Supplement to I.L. 70C1036 FIGURE 1. Digitrip with ARMs in Magnum Circuit Breaker Table of Contents Diagrams and Appendix 1.0 General...

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

Eaton Innovative TechnologyT XT50/100 surge protective device

Eaton Innovative TechnologyT XT50/100 surge protective device Instruction Manual IM01005014E Supersedes January 2014 Eaton T /100 surge protective device Contents Description Page Introduction.... 2 Installation.... 2 Specifications... 7 Operation..... 7 Warranty...

More information

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S DENISON HYDRAULICS Jupiter Power Supply Accessory Series S20-11715-0 Jupiter Power Supply Accessory S20-11715-0 Jupiter Power Supply Accessory w/ Driver Card S20-11712 Publ. 9-AM686 E-Mail: denison@denisonhydraulics.com

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL Trinetics UltraVacLT Single Phase Vacuum Capacitor Switch Installation and Operation Instructions UltraVacLT 15kV 95kV or 125kV BIL UltraVacLT 27kV 125kV or 150kV BIL Hubbell has a policy of continuous

More information

EDR-3000 Eaton Distribution Relay

EDR-3000 Eaton Distribution Relay EDR-3000 Eaton Distribution Relay Technical Data New Information Description Page 1. General Description.......................... 2 2. Applications............................... 2 3. Drilling Pattern.............................

More information

FNet Repeater Installation & Operator s Instruction Manual

FNet Repeater Installation & Operator s Instruction Manual FNet Repeater Installation & Operator s Instruction Manual October 2004 CTB Inc. Warranty FNet Repeater CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Metering module NZM-XMC

Metering module NZM-XMC Metering module NZM-XMC Recording and optimising energy Product Information Metering module NZM-XMC Metering and communication module for energy distribution and motor control centres Recording energy

More information

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module) SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension

More information

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Name No. of I/O points Model Safety inputs: 12, test outputs: 4 Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system

More information

Maximun Ratings and Electrical Characteristics at 25 C

Maximun Ratings and Electrical Characteristics at 25 C , FB25, FB35,, Power - Power L Voltage Current 50 to 1000 V 15-25-35-40-50 A FEATURES High case dielectric strength High forward surge current capability UL recognition file number E320541, Vol. 2. Universal

More information

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN Padmounted Switchgear MN285018EN Effective May 2017 Supersedes October 1994 (S285-80-1) COOPER POWER SERIES DC motor operator control installation and operation instructions DISCLAIMER OF WARRANTIES AND

More information

Application Guide. M 2174B Moloney Replacement Adapter Panel

Application Guide. M 2174B Moloney Replacement Adapter Panel Application Guide M 174B Moloney Replacement Adapter Panel CONTROLS Replacement Panel M 174B Adapts M 001 Series Digital Tapchanger Control to Replace Moloney/Tempo LTC Control Panel Connects easily to

More information

FTC-200 X-ray Tube Controller Users Manual

FTC-200 X-ray Tube Controller Users Manual Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4

More information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2. Terminal SSR G3S CSM_G3S_DS_E_7_ Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal

More information

O & M Manual for the Eaton ATC-100 Automatic Transfer Switch Controller

O & M Manual for the Eaton ATC-100 Automatic Transfer Switch Controller O & M Manual for the Eaton ATC-100 Automatic Transfer Switch Controller Instructional Booklet New Information Description Page 1. Introduction............................... 2 2. Hardware Description........................

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN Voltage Regulators MN225020EN Effective May 2015 Supersedes S225-40-4 November 2011 COOPER POWER Fiber-optic/RS-232 communications module installation and operation instructions SERIES DISCLAIMER OF WARRANTIES

More information

Clipper Power System Visor Series

Clipper Power System Visor Series Clipper Power System Visor Series Technical Data Supersedes TD.37B.21.T.E pages 1-8 dated October 2001 Description Page Applications.................................................. 2 General Description............................................

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com Owner s Manual with Fixed & Variable Outputs 1 AtlasSound.com Owner s Manual Description The Atlas Sound Variable Block is designed to reduce cost and wiring clutter in installations where multiple DC

More information

Operating comfort redefined Frequency Inverters M-MAX

Operating comfort redefined Frequency Inverters M-MAX Operating comfort redefined Frequency Inverters M-MAX The complete range of contac tors, efficient motor starters and variable speed drives for the motor circuit. New simple to install solutions based

More information

ABB Drives. User s Manual I/O Module Adapter AIMA-01

ABB Drives. User s Manual I/O Module Adapter AIMA-01 ABB Drives User s Manual I/O Module Adapter AIMA-01 I/O Module Adapter AIMA-01 User s Manual 3AFE 64661442 REV A EN EFFECTIVE: 1.12.2003 2003 ABB Oy. All Rights Reserved. 5 Safety instructions Overview

More information

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Solid-state Timer Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer

More information

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor Portable Power Monitor ZN-CTX/-CTM CSM_ZN-CTX_-CTM_DS_E 2 Easy and Quick Checking Power at the Worksite Display and record power consumption without stopping the power supply. Battery driven, mounted with

More information

CAUTION This device is sensitive to ElectroStatic Discharge (ESD). Therefore care should be taken during transport and handling.

CAUTION This device is sensitive to ElectroStatic Discharge (ESD). Therefore care should be taken during transport and handling. Rev. 2 28 September 2010 Product data sheet 1. Product profile 1.1 General description Hybrid high dynamic range amplifier module operating at a supply voltage of 24 V (DC) in an SOT115J package. The module

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Eaton Frequency Inverters SVX9000 and SPX9000. Modular, compact and configurable

Eaton Frequency Inverters SVX9000 and SPX9000. Modular, compact and configurable Eaton Frequency Inverters SVX9000 and SPX9000 Modular, compact and configurable Multiple communication protocols allow connectivity to an extensive range of automation systems. Modbus/TCP Modbus RTU Profi

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

One Channel and Two Channel DALI Relay Device

One Channel and Two Channel DALI Relay Device Installation Guide DGOZ-RLY-10A-01 DGOZ-RLY-10A-02 One Channel and Two Channel DALI Relay Device REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

Model Number Structure

Model Number Structure Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_4_2 International Standards for G3F Series, Same Profile as MY Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (model numbers

More information

Pure Sinewave Inverter

Pure Sinewave Inverter SINEWAVE INVERTER Pure Sinewave Inverter Model No. PST-25S-12E PST-25S-24E Manual Please read this manual before operating your inverter Notice of Copyright PST-255 inverter owner s manual 2004-2015 Samlex

More information

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Description Tripp Lite's SU80KX (80kVA) SmartOnline Modular 3-Phase

More information

Wall. No opening (Example: LA-030-W)

Wall. No opening (Example: LA-030-W) Thank you very much for choosing an EIZO product. Please read this User s Manual carefully to familiarize yourself with safe and effective usage procedures. Please retain this manual for future reference.

More information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G@-VD CSM_GH_GHD_DS_E_6_ New Models with International Standards Added to GH Series (-VD in model number). Same Profile as LY and LY Bi-power Relays Certified by UL, CSA, and VDE (models

More information

PRO-75 SERIES. User manual

PRO-75 SERIES. User manual PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Switching Frequency Test Conditions (AC3/AC4/AC53-a) Information Common to the G3J-T, G3J-S, and G3J CSM_G3J-T_G3J-S_G3J_common_DS_E_2_2 Engineering Data Load Current vs. Ambient Temperature Load current Io (A) G3J-T217BL G3J-T211BL G3J-S211BL G3J-211BL

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

MPP1700 User s Manual

MPP1700 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual PMDX-108-Output 8-Channel Isolated Output Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton,

More information

Metering Devices IQ 300

Metering Devices IQ 300 Effective: May 2001 Page 1 New Information Contents Description Page General Description......... 2 Specifications.............. 3 Field Wiring Connections.... 4 Page 2 Effective: May 2001 Applications

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977

More information

MMBZ16VAL. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data

MMBZ16VAL. 1. General description. 2. Features and benefits. 3. Applications. 4. Quick reference data High surge current unidirectional double ESD protection diodes 6 November 217 Product data sheet 1. General description Unidirectional double ElectroStatic Discharge (ESD) protection diodes in a common

More information

Trusted High Integrity Power Supply System ( Vac and 24 Vdc)

Trusted High Integrity Power Supply System ( Vac and 24 Vdc) PD_T8200 Trusted Trusted High Integrity Power Supply System (110-240 Vac and 24 Vdc) Product Overview The Trusted power supply assembly converts redundant main line voltages of either 110 Vac / 240 Vac

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Power Supply (48Vdc, 2.5A)

Power Supply (48Vdc, 2.5A) Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.

More information

Installer Guide. About SecureConnect. Contents. About this guide. Eaton SecureConnect. About the web portal

Installer Guide. About SecureConnect. Contents. About this guide. Eaton SecureConnect. About the web portal Eaton SecureConnect Installer Guide Contents About this guide.... i About SecureConnect.... i About the web portal...i About the SecureConnect app... 2 System requirements.... 2 How to set up SecureConnect...

More information

USER MANUAL. WBI412F41 AC current transducer

USER MANUAL. WBI412F41 AC current transducer Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 989 USER MANUAL WBI2F AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service:

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

GAMATRONIC, A SolarEdge Division.

GAMATRONIC, A SolarEdge Division. GAMATRONIC, A SolarEdge Division. 17 Hartum Street, POB 45029, Jerusalem 9777517,Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: info@gamatronic.com www.gamatronic.com The Power+ Premium 60 is

More information