DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. January Rev 1.31
|
|
- Victor Arnold
- 5 years ago
- Views:
Transcription
1 DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual January Rev 1.31
2 IMPORTANT SAFETY and USAGE INFORMATION Please review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only The Moving Pixel Company should perform service procedures. Do not attempt service yourself. Return the unit to The Moving Pixel Company for service. While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system. To Avoid Fire or Personal Injury or Damage to Equipment Qualified Personnel to Operate this Product This manual and the product marking assumes that the user has more than basic electrical/electronic circuit knowledge and is a person comfortable by experience and education to safely connect probes to electrical circuits and systems. Do not operate this equipment nor connect it to any circuit or system if you are not qualified to do so by either education or experience. Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use. Use only the external power supply that is included with the product. Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source. Ground the Product. This product is not inherently grounded through the grounding conductor of the power cord; it has a floating power supply. The negative lead of the power supply is directly connected to the metal shell of the unit and all SMA connections are also electrically connected to the metal shell of the unit. It is possible that improper connection to an external system could electrify the shell to potentially high voltages above ground. To avoid electric shock, the product must be tied to ground externally. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded. Any markings, symbols, or textual references to ground, GND, and similar refer to the metal shell of the unit and assume that the metal shell is tied to a saftey ground externally.
3 Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. The inputs are not rated for connection to mains or Category II, III, or IV circuits. Connect the probe reference lead to earth ground only, no floating grounds allowed. Power Disconnect. The power cord disconnects the product from the power source. Do not block the power cord; it must remain accessible to the user at all times. Do Not Operate Without Covers. Do not operate this product with covers or panels removed. Do Not Operate With Suspected Failures. If you suspect that there is damage to this product, have it inspected by The Moving Pixel Company. Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual s installation instructions for details on installing the product so it has proper ventilation. Symbols and Terms These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
4 These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product:
5 Before Operating the Instrument Verify the ambient temperature: 5 C to +45 C. Verify the operating humidity: 8% to 80% relative humidity at up to +32 C 5% to 45% relative humidity above +32 C up to +45 C noncondensing, and is limited by a maximum wet-bulb temperature of +29 C (derates relative humidity to 32% at +45 C) Verify the operating altitude: 3,000 m, derate maximum operating temperature by 1 C per 300 meters above 1500 meters altitude. CAUTION. Operate in upright position only, keeping cooling holes on the sides of the unit clear of obstructions. Power Supply Requirements for the external power supply (provided): Source Voltage VAC Frequency Hz Power Consumption 70 W maximum It may be helpful to check our website for any updates to this documentation before you operate the instrument: If you have any questions at all about the warnings or operating conditions listed above: STOP! Do not operate the instrument. Contact The Moving Pixel Company and resolve your question before continuing. Contacting The Moving Pixel Company Phone US Pacific Time Zone (UTC-8) Fax Address Web site The Moving Pixel Company 4905 SW Griffith Drive, Suite 106 Beaverton, Oregon USA information@movingpixel.com
6 Declaration of Conformity The Moving Pixel Company declares that the DPhyDecoderV1.2 product conforms to the following Standards: EN/IEC :2013, Class A Radiated Emissions AS/NZS CISPR 11:2011 Class A Radiated Emissions FCC (g):2014 Class A Radiated Emissions FCC :2014 Class A Radiated Emissions ICES-003:2012 Class A Radiated Emissions VCCI: Class A Radiated Emissions EN/IEC :2013, Class A Conducted Emissions AS/NZS CISPR 11:2011 Class A Conducted Emissions FCC :2014 Class A Conducted Emissions ICES-003:2012 Class A Conducted Emissions VCCI: Class A Conducted Emissions EN :2013 Industrial in the following areas: IEC :2008 ESD immunity IEC :2010 RF electromagnetic field immunity IEC :2012 Electrical fast transient/burst immunity IEC :2005 Power line surge immunity IEC :2013 Conducted RF immunity IEC :2009 Magnetic Field immunity IEC :2004 Voltage dips and interruptions immunity Equipment type: Test and measurement equipment, indoor use only. Pollution Degree 2 as defined in IEC Rated for indoor use only. This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference. Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object. For compliance with the EMC standards listed here, high quality shielded interface cables that incorporate low impedance connection between the cable shield and the connector shell should be used.
7 Product end-of-life handling Observe the following guidelines when recycling an instrument or component: Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product s end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately. This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2012/19/EU and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site ( Restriction on Hazardous Substances Directive 2011/65/EU EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restrictions of hazardous substances. 7
8 MIPI DPhy Decoder 1.0 General: The MIPI DPhy v1.2 Decoder (DPhyDkd) is the hardware probe that supports MIPI DPhy signal acquisition with protocol decode occuring on a host Windows PC. Users familiar with the predecessor product DphyDecoder will note a nearly complete overlap of function and look and feel. The DPhyDkd supports: sophisticated real-time triggering Rx mode and Sniff mode real-time status monitoring activity statistics status LED indicators Sniff mode: active probes, solder-down, for minimal loading of the device under test. Rx mode includes internal active termination and SMA connectors USB 3.0 for fast data transfer The control and decode software that is provided with DPhyDkd (DPhyDecoderCtl) interfaces to the hardware and provides the following features: Configuration control Disassembly of the captured information in a logic analyzer-like format. Reassembly and display of any video information captured Storage of captured video frame(s) to a file(s). Refer to the DPhyDecoderCtl document for a detailed treatment of all the software features. DPhyDkd support up to 4 data lanes and 1 clock lane. Data rate operation up to 2.5 Gb/s per lane is supported. Connection to the DUT is via 5 active solder-down probes (supplied), one per lane or via SMA for Rx mode. Power for the DPhyDkd comes from an external desktop universal power supply. It also features a Trigger output on an SMA connector that can drive into a 50 ohm termination. Configuration and control and PC acquisition of the captured data from the DPhyDkd is via a USB 3.0 connection to the PC-based software application DPhyDecoderCtl. Refer to the DPhyDecoderCtl manual for the details of operating this software. 8
9 2.0 Requirements: The DPhyDkd must be connected to a PC via USB 2.0/USB3.0. The PC must be running the DphyDecoderCtl application and must have the drivers (provided) installed correctly. This will require Admin privelages on the PC. The PC must be running Microsoft Windows Win7-32/64 bit or Win 8/Win 10 The MIPI DPhy signals being monitored must be nearly within specification from both a protocol and an electrical point-of-view. This becomes more important as the link bitrate increases. 9
10 3 Connections and Indicators 3.1 USB The USB connection between the unit and the PC is made via the rear panel. The connector is labeled USB. It accepts the B end of a mini-usb 3.0 cable. The cable provided has enhanced retention features. 3.2 Power This is covered in the next section Usage. 3.3 Front Panel Indicator LEDs There are 8 front-panel indicators. Except as noted, they are sticky in that if an event occurs, the LED will light for a fixed period of time so that a human observer can see it happen. From left to right they are and indicate as follows: Idle Green. There is no traffic at the present time HSTraffic Green. There is High Speed traffic present. LP Traffic Green. There is Low Power traffic present. BTA Green. A Bus Turn Around cycle is in progress ULPS Green. Bus is in Ultra Low Power State. TriggerGreen. The trigger conditions specified via the GUI have been met. Errors Red, not sticky (the associated indicator in the GUI is sticky). CRC and/or Checksum errors have been detected. The reason this indicator is not sticky is so that a user can get a real-time feel for the error rate and feedback if the user is making an adjustment that may affect the error rate. Spare Yellow, this is reserved for future use. Currently it comes on at power up and stays on. 10
11 3.4 Probe heads In Sniff mode, signal acquisition from the DUT is via 5 active, solder-down probe heads: one for the clock lane and one each for up to 4 data lanes. Lanes are labeled at the Decoder end of the cable. For the highest electrical performance, we recommend a small whisker of wire be soldered between the probe tip end and the circuit under test. This will give the system some mechanical flexibility and will help prevent damage to either the probe tip ends or the circuit under test. Unused probe heads should be wrapped up in an antistatic container such as a nickel bag. If a user expects to not use particular lanes long-term, the probe head and cable can be unplugged and removed from inside the unit. Removal will keep the probe head out of the user s way and lessen the likelihood of damage (but remember where you put it; they are easy to lose and quite expensive to replace!). Probe polarity is identified in the following illustration. Probe + should connect to D-PHY lane Dp, with probe connecting to D-PHY Dn. If the input resistors to the probe become damaged as a result of soldering/de-soldering, etc., they may be replaced with 1.33 K 1% 0603 resistors. All normal soldering and ESD precautions must be observed. Probe head tip resistors are user-replaceable. 10 spare resistors are provided for each probe head. Users are cautioned that probe tip resistor soldering replacement requires a fair bit of skill in order to avoid damage to the probe head circuit board. CONNECTOR onback + - HEATSHRINK (color varies, clear shown) When soldering the probe directly to traces or pads or vias, care must be taken to prevent mechanical stress to the probe head else circuit damage may result. 11
12 The colors on the end of the probes are meaningless. They are provided to help with probe logistics. When shipped, Data Lane one is Red, Data Lane two is Green, Clock is Clear, Data Lane three is Blue, and Data Lane 4 is White (following the resistor color code). The probes are all interchangeable, including the clock. However, calibration will be slightly affected by interchanging the probes. For usage information, see section 4 below. 3.5 SMA inputs In Rx mode, signal acquisition from the DUT is via 10 SMA connectors: two for the differential clock lane and two for each differential lane for up to 4 data lanes. Lanes are labeled at the Decoder end of the cable. In Rx mode, these signals are actively terminated by the unit in response to the protocol on the wires. 12
13 4 Operation 4.1 Modes: There are two modes of operation: Sniff mode and Rx mode. Sniff mode acquires the signal from the DUT via the active solder-down probe heads. This is generally used mid-bus when there is a DPhy Transmitter connected to a DPhy receiver and the user wants to monitor and/or decode the traffic on the bus. The active probes non-invasively allow the user to monitor the traffic. The unit does not interact with either the transmitter or the receiver. 4.2 Connections: Sniff mode: Connect the USB cable to the PC, and the probe heads to the DUT. Make sure the black ground wire is attached to the DUT ground. We have found that the best way to connect the solder-down probes to the DUT is to solder short (~7mm) whisker wires to each of the probe tips then down to the DUT. Tie the probe head to the DUT with some electrical tape to stabilize the setup and strailrelieve the whisker wires. If short whisker wires cannot work for a particular setup, the user can extend the length to the probe head by soldering a ohm resistor to the DUT then extending the other end to the probe head. This wire can be up to ~40mm before significant signal degradation occurs. Note that this additional resistance will cause some degradation of the DPhy signal amplitude. In critical applications, the probe tip resistors value should be reduced by the amount of the additional external resistance Rx Mode: Connect the DUT transmitter to the SMA connections via high-quality 50 ohm coaxial cables. We recommend the length not exceed 70cm. The limitation is not due to the high-speed nature of the signal; it is due to MIPI DPhy LP mode not being terminated at the receiver and yet having fairly fast risetimes. Longer connections result in many reflections during LP signals. After about 90cm of length, the decoder may get confused by the reflections. In Rx mode, the unit actively terminates the signals as required by the protocol. Further, it will also respond (as programmed by the user via the DphyDecoderCtl GUI) to BTA requests as a normal receiver would. This response is rudimentary and the unit does not have the capability to respond differently to different types of BTA requests. 13
14 Connect the external 24 volt power supply to DPhyDkd via the connector on the rear panel marked 24 Vdc. Note that there is a LED visible through a hole next to the power connector. This LED will light with a green color when power is applied to the unit. Upon power-up, the left-most two leds ( Idle and HS Traffic ) will blink back and forth a few times to indicate that the internal boot process is complete. This system is intended to be operated in a lab environment where proper grounding of all equipment and surfaces is implemented. The system monitors very small signals across a very wide frequency range and is easily upset by large EM fields and static discharges. 14
15 4.3 Clock delay line setting The DPhyDkd was designed to operate with systems that may not be within spec, particularly with respect to the clock-to-data timing relationship. We have provided an adjustment available through the GUI so that a user can optimize the timing. As the user operates closer to the maximum clock rate limit for the DPhyDkd (the setting becomes more sensitive with number of lanes), this setting gets very critical, working over a ~400pS range typically at 1.5Gbps. A clue that the timing needs adjustment is that the DPhyDkd has no errors at lower frequencies. If it detects errors at the highest bit rates, the user should try changing this setting over a +/- 200pS range. The GUI has a button that automates the search for the best possible setting of this delay line. 4.4 Synchronization In MIPI DPhy v1.2 at bitrates greater than 1.5 Gbps, transmitters are required to send a training sequence periodically so that receivers can optimize their sampling phase. The DPhyDkd hardware has enough timing margin such that it does not actually need to train to recover the signal as long as it was transmitted within spec since the timing variation allowed in the spec is less than the acquisition setup and hold time required by the DPhyDkd. However, if the transmitter is out of spec, the signal can still be acquired by using the methods outlined in the paragraph above (4.3). 15
16 5.0 Electrical specification for the DPhyDecoder V1.2 Characteristic Specification Notes Maximum data rate 2.5 Gb/s per lane Maximum clock rate 1250 MHz Input Impedance, active probes Trigger Out, impedance Trigger Out, amplitude 2.0k to ground in parallel with less than 1pF, each side of the Differential input ~50 ohms ~3.3V open circuit 1.65V into 50 ohms This will slightly reduce the LP voltage high signal depending on the output impedance of the source Logic low is ground. Probe Head tip resistors 1.33k, 1% 0603 package style, lead-free Storage Capacity, video data 256MBytes 512Mbytes total vector storage (half is overhead). Clock delay range ~9 ns External Power Supply 24 Vdc, 50 watts max Universal, supplied Operating Environment degrees C Less than 15,000 elevation No condensing humidity Lab environment No strong, stray fields No static discharges Weight ~1170 grams approximate, without supply Weight, power supply and cord ~475 grams approximate Overall Dimensions 345mm x 195mm x 80mm Approximate, without supply Note that this product is RoHS compliant, even though it is currently exempt from RoHS requirements. 16
17 For more information contact: The Moving Pixel Company 4905 SW Griffith Drive Suite 106 Beaverton, Oregon phone PST 17
DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. June Rev 1.0
DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual June 2015 - Rev 1.0 1 MIPI DPhy Decoder 1.0 General: The MIPI DPhy v1.2 Decoder (DPhyDkd) is the hardware probe that supports
More informationP344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31
P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual January 2018 - Rev 1.31 P344 MIPI D-PHY Probe IMPORTANT SAFETY and USEAGE INFORMATION Please review the following safety precautions to
More informationDPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0
DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual March 2013 - Rev 1.0 1 MIPI DPhy Decoder 1.0 General: The MIPI DPhy Decoder (DPhyDkd) is the hardware probe that supports protocol
More informationDPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2
DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual February 2012 - Rev 1.2 1 MIPI DPhy Preprocessor 1.0 General: The MIPI DPhy Preprocessor (DPhyPre) is the hardware probe
More information1103 Power Supply (SN B and Above) Instruction Manual
xx ZZZ 1103 Power Supply (SN B040000 and Above) Instruction Manual *P071254401* 071-2544-01 xx ZZZ 1103 Power Supply (SN B040000 and Above) Instruction Manual Warning The servicing instructions are for
More informationP5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD
xx P5200A Series High Voltage Differential Probes ZZZ Installation and Safety Instructions & Product Documentation CD *P071288902* 071-2889-02 Copyright Tektronix. All rights reserved. Licensed software
More informationTETRIS 2500 High Impedance Active Probe. Instruction Manual
TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationTCP305A & TCP312A AC/DC Current Probes Instructions
xx ZZZ TCP305A & TCP312A AC/DC Current Probes Instructions www.tektronix.com *P071303200* 071-3032-00 Copyright Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its
More informationP338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual. October Rev 1.1
P338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual October 2012 - Rev 1.1 PG3A Pattern Generator P338 MIPI D-PHY Probe 1.0 General: The P338 probe features 2 links each comprising 4 data lanes and
More information38 MHz Passive Voltage Probe R&S RT-ZP1X
Manual 38 MHz Passive Voltage Probe R&S RT-ZP1X 1333.1370.02 Printed in Germany Test and Measurement 2 Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit our
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationUser Manual VX4234 Digital Multimeter Module
User Manual VX4234 Digital Multimeter Module 070-9139-02 This document applies for firmware version 1.00 and above. General Safety Summary Review the following safety precautions to avoid injury and
More informationSCC-AO10 Isolated Analog Output Module
USER GUIDE SCC-AO10 Isolated Analog Output Module Conventions The SCC-AO10 is an isolated voltage output module with an output range of ±10 V. The output voltage level is controlled by the DAC output of
More informationNI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.
INSTALLATION GUIDE NI 8262 This document explains how to set up your NI 8262 expansion module. What You Need to Get Started Unpacking To set up and use your NI 8262 module, you need the following: A PXI
More informationRSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions
xx ZZZ RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions *P071332301* 071-3323-01 xx ZZZ RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions Register now! Click
More informationPML 791-RO Low-Z Passive Probe. Instruction Manual
PML 791-RO Low-Z Passive Probe Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject
More informationRSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions
xx ZZZ RSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions *P071348300* 071-3483-00 xx ZZZ RSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions Register now! Click
More informationUser s Manual Model PBL100 Logic Probe IM E. 4th Edition
User s Manual Model 701988 PBL100 Logic Probe 4th Edition Foreword Thank you for purchasing the PBL100 100 MHz Logic Probe (Model 701988). This user s manual describes the functions, operating procedures,
More informationNI Serial Hardware Specifications Guide
NI Serial Hardware Specifications Guide Contents This document lists safety and compliance information for NI Serial hardware, as well as physical specifications, software characteristics, and recommended
More information±15 V Current-Limited Power Supply
USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus EU Declaration of Conformity We declare that the accompanying
More informationU4421A MIPI D-PHY Protocol Analyzer and Exerciser. Hardware and Probing Guide
U4421A MIPI D-PHY Protocol Analyzer and Exerciser Hardware and Probing Guide Notices Agilent Technologies, Inc. 2012-2014 No part of this manual may be reproduced in any form or by any means (including
More informationRSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions
xx ZZZ RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions *P071332300* 071-3323-00 xx ZZZ RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions Register now! Click
More informationUSB-2001-TC. USB-based Thermocouple Input. User's Guide
USB-2001-TC USB-based Thermocouple Input User's Guide Document Revision 6A November 2014 Copyright 2014 Trademark and Copyright Information Measurement Computing Corporation, InstaCal, Universal Library,
More informationPMT 201A-RO High Impedance Passive Probe. Instruction Manual
PMT 201A-RO High Impedance Passive Probe Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationThis simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.
LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power
More information374 FC/375 FC/376 FC. Clamp Meter. Safety Information
374 FC/375 FC/376 FC Clamp Meter Safety Information 3-Year Limited Warranty. Go to www.fluke.com to register your Product, read the Users Manual, and find more information. A Warning identifies conditions
More informationdesigned for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual
designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual Copyright 2017 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationKHT 6000 C HV-Probe Calibrator. Instruction Manual
KHT 6000 C HV-Probe Calibrator Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject
More informationFeatures. Applications and Benefits TRC ELECTRONICS, INC
Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and
More informationCTB MIPI CPhy/DPhy Termination Board Data Sheet & User Manual. June Rev 1.2
CTB MIPI CPhy/DPhy Termination Board Data Sheet & User Manual June 2018 - Rev 1.2 CTB MIPI C-Phy/D-Phy Termination Board 1.0 General: The Termination Board (TB) is a product that properly terminates a
More informationTT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL
TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC-1010.2-031 CAT I or CAT II, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual:
More informationGigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.
LGC010A-R2 LGC011A-R2 LGC012A-R2 LGC013A-R2 LGC014A-R2 LGC015A-R2 LGC016A-R2 LGC017A-R2 Gigabit Miniature Media Converters Connect Gigabit Ethernet copper ports to fiber optic cable. FCC and IC RFI Statements
More informationSCC-RLY01 Relay Module
USER GUIDE SCC-RLY01 Relay Module Conventions The SCC-RLY01 contains one single-pole double-throw (SPDT) nonlatching relay capable of switching 5 A at 30 VDC when using an SC-2345 or SC-2350, or 250 VAC
More informationGelo LED Driver 100W, Single output RGLD100-24
Features Gelo LED power supplies are designed specifically for use in refrigeration, retail display and sign applications. The industry standard footprint and very low profile design provide great benefits
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationDS-1H05 Ethernet-over-Coax Extender. User Manual
DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,
More informationPMT 221A High Impedance Passive Probe. Instruction Manual
PMT 221A High Impedance Passive Probe Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationManual Version: V1.00. Video Decoder Quick Guide
Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang
More informationGelo LED Driver 100W, Single output, Constant Voltage RGLD100-24
Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and
More informationINSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1
INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This
More information300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES
INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the
More informationGPS Synchronization Module
GPS 430-II GPS Synchronization Module Introduction Instruction Sheet The GPS 430-II GPS Synchronization Module guarantees that the time clock uncertainty of the Fluke 430-Series II Power Quality Analyzers
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: Supplement Issue: 8 Part Number: 1625019 Issue Date: 9/17 Print Date: October 2011 Page Count: 12 Revision/Date: 11 This supplement contains information necessary to ensure the accuracy of
More informationMDM 011-Z1 Regen Resistor
MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
More informationNI PXI-2567 Specifications
NI PXI-2567 Specifications 64-Channel Relay Driver Module This document lists specifications for the NI PXI-2567 relay driver module. All specifications are subject to change without notice. Visit ni.com/manuals
More informationWarranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
SPECIFICATIONS USB-6501 24-Channel, 8.5 ma, Digital I/O Device Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
More informationUser s Manual Model PBL250 Logic Probe IM E. 3rd Edition
User s Manual Model 701989 PBL250 Logic Probe 3rd Edition Foreword Thank you for purchasing the PBL250 250 MHz Logic Probe (Model 701989). This user s manual describes the functions, operating procedures,
More informationMetro-Optical Transport Access Nodes
OnSite 1052 & 1063 Series Metro-Optical Transport Access Nodes Quick Start Guide Important This is a Class A device and isnot intended for use in a residential environment. Part Number: 07MOS10xx-QS, Rev.
More informationEOS-6000 Series Optical A/B Switch User Manual DC Version
EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2
More informationNI PXI-1042 Series Power Supply Shuttle
USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused
More informationINSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction
INSTALLATION INSTRUCTIONS Terminal Block for the Contents Introduction This guide describes how to install and connect signals to the National Instruments TB-2630B terminal block to configure your switch
More informationLine Impedance Stabilization Network (LISN)
Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any
More informationCompliance. Copyright 2012 GHS Corporation All Rights Reserved.
Compliance Your PowerTAP pedal power has been tested and complies with the following Standards and Directives as set forth by the European Union: Council Directive(s): 89/336/EEC Electromagnetic Compatibility
More informationIndustrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide
Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.
More informationLED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-
LED PANEL LED-7TC Innovation, Quality, Performance User Manual Please read the instructions carefully before use 15- 9. Fixture Cleaning TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationKeysight U4421A MIPI D-PHY Protocol Analyzer and Exerciser. Hardware and Probing Guide
Keysight U4421A MIPI D-PHY Protocol Analyzer and Exerciser Hardware and Probing Guide Notices Keysight Technologies 2012-2015 No part of this manual may be reproduced in any form or by any means (including
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationKvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2015 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Monday 21 st September, 2015 We believe that the information contained herein was accurate
More informationAgilent 34401A 6½ 桁マルチメータ ユーザーガイド
Agilent 34401A 6½ 桁マルチメータ ユーザーガイド Safety Information General Do not use this product in any manner not specified by the manufacturer. The protective features of this product may be impaired if it is used
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationCPCI System Subrack 1 U
User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this
More informationUTAH-100/XHDA SERIES
Utah Sandar AS User Manual & Installation Guide UTAH-100/XHDA SERIES SD & HD3G Digital Distribution 1:4 & 1:8 CONTENTS CONTENTS... 2 INTRODUCTION... 3 WARRANTY... 3 DOCUMENT REVISION HISTORY... 3 SAFETY
More informationAS1008-P AS1026-P AS2008-P AS2024-P User Manual
Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product
More informationTruVision IP Thermal Camera Installation Guide
TruVision IP Thermal Camera Installation Guide P/N 1073335-EN REV B ISS 19OCT17 Copyright Trademarks and patents Manufacturer Certification 2017 United Technologies Corporation, Interlogix is part of UTC
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationPicoScope 9000 Series PC Sampling Oscilloscopes. Quick Start Guide
PicoScope 9000 Series PC Sampling Oscilloscopes Quick Start Guide PicoScope 9000 Series PC Sampling Oscilloscopes Quick Start Guide DO134-8 Issue record: 17.07.08 First version. 20.11.08 Added 9211. 27.04.10
More informationU3-88c User s manual - Revision 1.2
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the
More informationTypical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes
EUC160QxxxDT(ST) 160W Fourchannel Constant Current IP67 Driver Features Ultra High Efficiency (Up to 92%) Four Channels Output Active Power Factor Correction (0.99 Typical) Constant Current Output Input
More informationNetwork Camera. Quick Guide DC-B1203X. Powered by
Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE
More informationSCXI -1313A Terminal Block
INSTALLATION GUIDE SCXI -1313A Terminal Block Conventions This guide describes how to install and use the SCXI-1313A terminal block with an SCXI-1125 module. The SCXI-1313A terminal block is shielded and
More informationTLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions
xx ZZZ TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions www.tektronix.com *P077059110* 077-0591-10 Copyright Tektronix. All rights reserved. Licensed software products
More informationOM GHz, OM GHz Optical Modulation Analyzer Installation and Safety Instructions
xx ZZZ OM4245 45 GHz, OM4225 25 GHz Optical Modulation Analyzer Installation and Safety Instructions *P071341400* 071-3414-00 xx ZZZ OM4245 45 GHz, OM4225 25 GHz Optical Modulation Analyzer Installation
More informationAdd 10/100 copper ports to a High Density Media Converter Chassis.
LMC5605C LMC5603C-SC-2KM LMC5603C-SC-40KM LMC5603C-50SC-40KM LMC5604C-1SFP LMC5603C-ST-5KM LMC5603C-10SC-20KM LMC5603C-2SFP LMC5603C-SC-5KM LMC5603C-50SC-20KM LMC5603C-ST-2KM LMC5603C-ST-40KM LMC5603C-10SC-40KM
More information80W (16V/5A) Power Supply with USB Output. User Manual
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A
More informationNI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529
INSTALLATION INSTRUCTIONS NI TB-2634 4 32 2-Wire Terminal Block for the NI PXI-2529 Introduction This document describes how to install and connect signals to the National Instruments TB-2634 terminal
More informationACCESS 9340/9360 Meter Input/Output Module
Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the
More informationIVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter
#6-32 GETTING STARTED GUIDE IVN-8561 100BASE-T1 Media Converter IVN-8561 100BASE-T1 Media Converter POWER P1 P3 MASTER LINK/ACT POWER PORT 4 5V 2.8W MAX This document describes how to begin using the IVN-8561
More informationKEZ-c2TR28V12XIR HD-TVI 1080p Varifocal IP66 Super Beam IR True WDR Turret Cameras with OSD, CVBS Output and UTC Control
KEZ-c2TR28V12XIR HD-TVI 1080p Varifocal IP66 Super Beam IR True WDR Turret Cameras with OSD, CVBS Output and UTC Control Quick Operation Guide Thank you for selecting this KT&C Omni EZHD Series product.
More informationDVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL
DVBus 8050-16, 8050-24 and 8050-32 Multiplexer and demultiplexer assemblies for 16-32 video channels USER MANUAL 1. Description DVBus 8050 systems transmit 10-bit digitized video signals over one optical
More information2 Mesa Ethernet Dock User s Manual
owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged
More informationEH-RIO IP67 Profibus-DP I/O modules
Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP
More informationAppearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC
Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration
More informationGeneral Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at
General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years (1 year for accessories) from the date of purchase of the product by the
More informationController Specifications
INRODUCTION Chromium Controller Specifications FOR USE WITH Chromium Controller & Accessory Kit PN-120223 NOTICES Notices Manual Part Number CG00020 Rev B Legal Notices 2017 10x Genomics, Inc. All rights
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationEC Series. Safety Guide
EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support
More informationUSB 3 Extenders. 4-Port Point-to-Point Extender System User Guide
USB 3 Extenders 4-Port Point-to-Point Extender System User Guide Document 411-0024-30 Rev A June 2018 Contents Introduction...3 Features...3 Unpacking...3 A Quick Look at the USB 3 Extenders...4 The Local
More informationIndustrial SFP/SFP Multi-Power Mode Converter
MARCH 2008 LGC300A Industrial SFP/SFP Multi-Power Mode Converter Copyright 2008. Black Box Corporation. All rights reserved 55 80619BB 00 A1 1000 Park Drive Lawrence, PA 35055 1018 724 746 5500 Fax 724
More informationService Manual. P GHz Differential Probe
Service Manual P7330 3.5 GHz Differential Probe 071-1057-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you
More informationOPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL
OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT KEPCO INC. An ISO 9001 Company. MODEL 250W ATE 6-25, ATE 15-15, ATE 25-10, ATE 36-8, ATE 55-5, ATE 75-3, ATE 100-2.5, ATE 150-1.5, ATE
More informationSLA Battery Capacity Analyzer
Model: 601B SLA Battery Capacity Analyzer USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation,
More informationTA MHz Oscilloscope Probe USER S GUIDE
TA150 350 MHz Oscilloscope Probe USER S GUIDE Copyright 2012 Pico Technology Ltd. All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationKEZ-c1TR28V12XIR HD-TVI 720p Low Light Varifocal IP66 EXIR Turret Cameras with OSD, CVBS Test Output and UTC Control
KEZ-c1TR28V12XIR HD-TVI 720p Low Light Varifocal IP66 EXIR Turret Cameras with OSD, CVBS Test Output and UTC Control Quick Operation Guide Thank you for selecting this KT&C Omni EZHD Series product. For
More informationSimple Logger II Series
Simple Logger II Series Quick Start Guide ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationUV Power Flood. User Manual. Order code: EQLED029
UV Power Flood User Manual Order code: EQLED029 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make
More information