Who are Aqua Cooling?

Size: px
Start display at page:

Download "Who are Aqua Cooling?"

Transcription

1

2 Data Centre Cooling

3 Who are Aqua Cooling? Started in 2001, head office based in Fareham, with regional offices in Midlands & North Market leaders in Air Conditioning, Industrial Cooling and Data Centre Cooling All types of cooling solutions available Adiabatic Cooling, Free Cooling, Air Blast Chillers ColdLogik Data Centre Rack Management Solutions Intelligent Rack PDU solutions Queen s Award for our Patented Leak Prevention System (LPS) for Data Centres Cooling capacities from 1kW to 1.6mW and above Operating temperatures of -45 C to +120 C Fully trained engineers to install, commission and service all equipment 24/7/365 service for any breakdown or repair

4 Clients Northrop Grumman

5 Rear Door Coolers In-row Coolers Aisle containment Coolers & Chillers Cabinets and Patching Frames Soundproof Cabinets Intelligent Access, Monitoring & Power

6 Traditional Aisle Containment Containment of hot or cold aisles and ducting hot air from cabinets are intended to prevent cool/exhaust air mixing within server rooms. Generally rows of cabinets face each other so that cool air can reach the equipment air intakes at the set temperature point for the room. A more recent addition to the consideration of above floor containment is below floor air flow control. A range of underfloor panels can be fitted within the raised floor plenum to create efficient cold air pathways direct to the raised floor vented tiles. Containment is generally implemented by physical separation of the hot and cold aisles, using blanking panels, PVC curtains or hard panel boards. Containment strategies could differ based on various factors including server tolerance, ambient temperature requirements and leakage from data centres.

7 Traditional Cold Aisle Containment Cold aisle containment with internal cooling can be deployed in a traditional raised floor environment or on a slab. CAC with internal cooling has a focused cooling approach and contains the cold air by enclosing the cold aisle using top ceiling panels and doors at the end of the aisle.

8 Low Density Aisle Containment Over 70% of server failures occur in the uppermost third of the rack where the heat rises overheating the upper equipment Aisle containment assists with delivering an even controlled temperature across all servers no matter where they are housed within the rack by reducing the airflow speed within the aisle. Convex roofs prevents air buffeting, which you get with a flat roof design This thermal dynamic improvement increases the overall efficiency and assists in providing an even column of cold air over the full height of the cabinet

9 Traditional Hot Aisle Containment The primary difference between HAC and CAC is that HAC is trying to contain the hot air to make sure that the return air temperature to the cooling unit is high, while the focus of CAC is on supplying cold air to the cold aisle where the equipment air intakes are located. The HAC approach can result in high efficiency of the cooling unit, but because the cold air distribution to the servers is open and exposed to disturbances from the room, it has a higher risk of not providing the server with its required input temperature.

10 Coldlogik CAP & DAX Systems To improve the efficiency of a CRAC based data centre design, ColdLogik controlled air path CAP units isolate and guide hot air out of the top of the cabinet into a ceiling plenum The primary function of the Directional Airflow Exhaust DAX system is the removal and distribution of heat from the rear of a 19 cabinet in an energy efficient and controlled way. Removing hot air from each cabinet by ducting the air through funnels on the top of the cabinet in a controlled manner through to the ceiling plenum

11 Medium Density Aisle Containment Traditional Aisle Containment with Room Conditioning Convex roofs prevents air buffeting, which you get with a flat roof design Consequently this thermal dynamic improvement increases the overall efficiency and assists in providing an even column of cold air over the full height of the cabinet

12 High Density Aisle Containment Coldlogik Rear Door Cooler, options allow up to 70kW per rack Retro-fit Module available for competitor or OEM racks Works with supply water temperature up to 24 C (ASHRAE) Able to reduce annual Data Centre Cooling costs up to 93% Fully controllable via Modbus, BACnet, RS485 & SNMP CEEDA Gold Award Status DCD North America 2014 Award Winner 2013 Queen's Award for Enterprise in the Innovation category

13 High Density Aisle Containment ColdLogik Rear Door Coolers replace the traditional approach to Data Centre cooling by removing low and high density heat loads. Rear door cooling has added benefit of reducing the real estate waste by hot aisle/cold aisle, in row cooling, CRAC cooling and aisle-containment designs. Waste heat generated by active equipment within a cabinet is removed at source by water cooling. Water is 3,500 times more effective than air by volume. Under normal circumstances, water and computing are not a good mix, however by utilising a patented LPS (Leak Prevention System) the ColdLogik solution operates without fear of leakage.

14 Rear Door Cooler Operation Exit air returned to data centre at pre-determined temperature by control panel Room ambient air is pulled into the front of the cabinet Coil removes heat at source Active equipment air exhausted to cooler

15 Rear Door Coolers Coldlogik Cabinets fitted with Rear Door Coolers

16 Cooler Options Retro-fit Rear Door Cooler CMS Control Panel & Controller Available in 42U & 48U, 300mm wide Cooling up to 70kW CMS (Coldlogik Management System) (available as 2U rack mounted or fitted in door)

17 Zero Aisle Cooler Zero Aisle Cooler provides an alternative method to fitting a Rear Door Cooler on to a Coldlogik cabinet or an OEM cabinet. Unlike a hinged door, which typically takes up mm of aisle space, the Zero Aisle Cooler moves from front to rear on an overhead system and floor based wheels to take up no more than its original footprint. When fully retracted, the distance between the back of the cabinet and the rear of the cooler is up to 1m of clearance, allowing for near unrestricted access and working space. This also allows retention of the OEM rear door for EMC requirements of some systems The runners can also be mounted to a mechanical infrastructure without fixing on top of the cabinet

18 LPS (Leak Prevention System) Chiller & Free Cooling Module Cooling Distribution Unit (CDU)

19 Coldlogik Server Cabinets 1000kg and 1500kg load bearing options 5 heights, 2 widths, 4 depths as standard Custom cabinets also available Rigid bolted construction Superior standard door venting with 80% airflow Superior Curve door venting with 86% airflow Multi depth mounting Multi cable access through top and base Quick release cladding Left or right hand hinged Internally locking side panels Houses all major server brands

20 Intelligent Rack PDU s Can be configured up to 48 sockets per unit All socket configurations, C13, C19, BS1363, Shuko Supplying a maximum 1,600 PDU s, 76,800 sockets Daisy chain up to 32 PDU s Supports 50 master PDU s Support 16A, 32A, 63A, with 1P & 3P options Local GUI interface as standard Works with all DCIM platforms SNMP & BMS options 5 year warranty Strip Power Monitoring Per Socket Monitoring Strip Power Monitoring & Per Socket Switching Per Socket Monitoring & Switching All PDU s come with bill-gradeable monitoring 8x Temperature Sensors Humidity Sensors 3x Volt Free Contacts Security Interface (doors contacts, locks) A complete range of supporting accessories

21 ) ries Can be configured up to 48 sockets per unit Intelligent Rack PDU s All socket configurations, C13, C19, BS1363, Shuko Supplying a maximum 1,600 PDU s, 76,800 sockets Complete Range of PDU options from Strip Power Monitoring Per Socket Monitoring Strip Power Monitoring & Per Socket Switching Daisy chain up to 32 PDU s Supports 50 master PDU s Per Socket Monitoring & Switching All PDU s come with bill-gradeable monitoring Support 16A, 32A, 63A, with 1P & 3P options Local GUI interface as standard Works with all DCIM platforms SNMP & BMS options 5 year warranty

22 Chillers & Coolers

23 Data Centre Cooling Data Centre chiller applications is increasing around the world, as owners and operators understand their mission critical need for uptime throughout the year. Aqua can deploy a large number of different configurations in data centres. These can be water cooled, air cooled and condensation free coolers with evaporative condensers.

24 Aqua Free Cooling Aqua Free Cooling is the fast and effective way to reduce your energy costs and your carbon footprint on refrigerated process water cooling applications. It s the smart choice for return on investment, with payback in as little as six months. With interest free loans available from The Carbon Trust for qualifying companies, which allow payback at the same rate as the savings. This is achieved by utilising Aqua s low energy, dry air cooler and Free Cooling technology which can partially or fully reduce the chiller depending on ambient air temperature. Aqua Cooling have developed this comprehensive and fully automated Free Cooling package for easy installation on all chilled water systems. Existing installations can also benefit from the same significant energy savings by retro-fitting Aqua s Free Cooling technology.

25 Aqua Free Cooling

26 Adiabatic Air Blast Coolers Pulsed adiabatic spray operation to minimise water usage Adiabatic system purge timer ensures that stagnation of water cannot take place Air thermostat locks out adiabatic usage in ambient temperatures below design figures Features include: Counter flow spray nozzles for even spray coverage across the entire coil surface area Spray booster pump gives approx. six bar of water pressure at the nozzles giving a fine mist UV lamp UV sterilisation treatment for adiabatic water feed

27 Adiabatic Air Blast Coolers Low Noise Levels, Low Input Powers No additional charge over stage control on V-bank units Controls are pre-commissioned prior to despatch helping to reduce setup time Units are despatched in fully operational form with no on-site assembly required Adiabatic option available for high ambient/low water temperature applications Range of materials available offering extended life in varying environments Modern, safe alternative to cooling towers, offering reduced running and maintenance costs

28 Hybrid Ambient Cooler Water savings, the system operates dry for the majority of the year, only when the ambient air temperature gets close to the set point will the adiabatic system operate. This can be as little as 1 or 2% of the year. No spray or pooling, mains water is delivered directly to pads via a pumping system to ensure adiabatic water is correctly distributed No risk of bacteria, excess water is recirculated via a UV filter before being delivered back to the pads and adiabatic water is refreshed on a regular basis Flexibility with siting, can be located around other plant & machinery without any risk of equipment getting wet from adiabatic spray Plume free, as saturated air passes through the coil it is heated away from saturation and creates no plume Each hybrid cooler can provide cooling from 82kW to 572kW

29 Hybrid Ambient Cooler WATER DISTRIBUTION System distributes water through adiabatic pad No risk of contamination, process water operates in a closed circuit with no need for chemical water treatment Hot Water Enters Cold Water Exits ADIABATIC PAD Ambient air drawn through adiabatic pad Water falling through pad is evaporated; adiabatic effect cools air Cold moist air is drawn through the cooling coil Cold moist air cools fluid passing through the coil, turning to warm air above saturisation point, resulting in no plume Water Catchmemt Tray Water Pump & UV Filter

30 How Ambient Works Dry bulb temperature: Ambient Coolers and how they work: Wet bulb temperature: Types of Cooling Systems Resultant temperature: 32 C Resultant temperature: 21 C

31 Aqua Free Cooling

32 Environmental Data Annual Wet Bulb UK Weather Profile Design water supply temperature of 24 C Temperature difference of 3 C Total number of hours above design limit; 4 hours Hours/Year Wet Bulb C 20.5 C 21.0 C 21.5 C 22.0 C 22.5 C 23.0 C 23.5 C 24.0 C 24.5 C

33 Water Chillers Aqua offer a complete range of water chillers with options for the following Water temperatures from -15 C to 25 C Pumps upto 8 bar on either Single or Run & Standby Water Tanks Non-ferrous water circuit Ambient conditions from -20 C to 50 C Also Bespoke Designs available

34 SPX Cooling Towers Distributor for

35 Specialist Cooling Solutions Cooling Towers Evaporative towers are able to get within 3 C of wet bulb so using their technology within the overall design means they can be used as primary cooling with wet bulbs up to 22 C. After this the cooling towers can either revert to cooling water cooled chillers or, if air cooled chillers are being utilised,turn off completely. This is a highly efficient, cost effective cooling resource with PUEs as low as Boreholes With borehole water temperatures across Europe generally below 14 C, this technology can be used throughout the year and is the greenest, most energy efficient way of cooling a data centre. The PUE of these systems can be as low as 1.03 and, as a geological source, the resilience of this system is unrivalled as it is hurricane and tornado proof. We can provide analysis of your location from desktop survey to full test drills to ensure that your chosen location is suitable for this system at very reasonable costs. River or Sea Water Again, the ColdLogik system is unrivalled in its ability to use alternative cooling sources. The CDU LPS is designed so that it can take both river and sea water as a primary cooling method whilst maintaining the systems integrity. The resulting systems have incredibly low PUE figures and extremely low ROI compared to alternatives. If your company s goal is to reduce its carbon foot print and cut costs, the Coldlogik cooling systems will fit your plans and budgets perfectly.

36 Aqua Chiller Hire Aqua Cooling Solutions are able to offer a range of hire units From 3-500kW, with or without pumps and tanks. With a minimum hire period of just one week, equipment hire can be an extremely convenient and cost effective option for clients needing a temporary or emergency solution, for example in the event of Production problems and/or equipment failure Short production runs Plant renovation/refurbishment Product/equipment testing Load evaluation Our hire range has the full support of a national network of engineers who will ensure that your equipment is correctly and promptly installed. For those clients looking for a more permanent solution, but without heavy capital outlay, we also offer contract leasing. This is available on all the products within our current range, on either a 3 or 5 year term. Aqua Cooling also keep a range of chiller units and equipment in stock, available for immediate delivery from our main UK depot.

37 I told you Aqua Cooling is the best! Funnies

38 Aqua Cooling allow us to put our data centre anywhere with their technology Funnies

39 Aqua Review Complete range of chillers, coolers and towers to suit all requirements Free Cooling, Adiabatic Cooling, Air Blast Chillers, Cooling Towers Award winning LPS (Leak Prevention System) 24/7/365 Maintenance Contracts available Rear Door Coolers with cooling up to 70kW per door Complete range of server cabinets with all configurations available Customisable Soundproof enclosures Custom cooling solutions Aisle Containment Solutions Full range of Intelligent rack PDU s, that all can daisy chain to 32 units

40 Thank you for your time Don t forget to visit us on

41

42

CL20 Rear Cooler. New Generation Computer Room Cooling

CL20 Rear Cooler.  New Generation Computer Room Cooling CL20 Rear Cooler New Generation Computer Room Cooling A New Approach ColdLogik Rear Coolers, produced by USystems, replace the traditional approach to data centre cooling, allowing loads of up to 58 kw

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc. Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Evaporative free air cooling technology Providing evaporative free air cooling solutions. Evaporative free air cooling technology Providing evaporative free air cooling solutions. Creating an effective workspace environment data centre free air cooling technology FreeCool - Evaporative Free

More information

Reducing Data Center Cooling Costs through Airflow Containment

Reducing Data Center Cooling Costs through Airflow Containment FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental

More information

Total Modular Data Centre Solutions

Total Modular Data Centre Solutions Sector Data Centre Total Modular Data Centre Solutions www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 01 Standardised Modular Designs to fit your needs Our modular system

More information

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Switch to Perfection

Switch to Perfection Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of

More information

Impact of Air Containment Systems

Impact of Air Containment Systems White Paper June 2012 WP-20 Impact of Air Containment Systems Reducing Energy Consumption Introduction: The Importance of Maintaining Data Center Cooling Energy Efficiency Data centers are mission-critical

More information

How to Increase Data Center Efficiency

How to Increase Data Center Efficiency How to Increase Data Center Efficiency Shivani Shukla Potkar Product Marketing Manager Pentair Electronics Protection High cooling efficiency & and reduced power consumption enhances the balance between

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered Survey and Audit Service Schedule Airflow and Thermal Imaging Survey Service Schedule Data Centre Solutions Expertly Engineered Consult optimisation, audit and survey services Data Centre Services Workspace

More information

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market

More information

Liebert DCW CATALOGUE

Liebert DCW CATALOGUE Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers

More information

MSYS 4480 AC Systems Winter 2015

MSYS 4480 AC Systems Winter 2015 MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and

More information

Reducing Energy Consumption with

Reducing Energy Consumption with Reducing Energy Consumption with Passive Cooling Ian Cathcart, RCDD Technical Support Manager Technical Support Manager Chatsworth Products, Inc. Thermal Management: Mission Critical Data center heat loads

More information

Industry leading low energy evaporative fresh air cooling.

Industry leading low energy evaporative fresh air cooling. Industry leading low energy evaporative fresh air cooling. Freecool Evaporative Free Air Cooling by Workspace Technology delivers innovative low energy cooling for a range of applications including data

More information

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Data Centre Solutions Expertly Engineered Indirect Adiabatic and Evaporative

More information

Data Centre Infrastructure

Data Centre Infrastructure Data Centre Infrastructure Aisle Containment Solution Aisle Containment is a popular way of cooling high density server installations. Aisle containment can work in two ways: Cold Aisle Containment where

More information

A separate CRAC Unit plant zone was created between the external façade and the technical space.

A separate CRAC Unit plant zone was created between the external façade and the technical space. Nominee: FES Co Ltd Nomination title: HP Cold Cube The Doxford Facility is a highly secure Data Centre. The challenge was to take advantage of the previous investment in highly resilient infrastructure

More information

Over IP Group. Data Centre Infrastructure Management (DCIM)

Over IP Group. Data Centre Infrastructure Management (DCIM) Over IP Group Data Centre Infrastructure Management (DCIM) Mission To Protect the World s Network Through Innovation Let s Get Connected Over IP Group Agenda The Aim of CenterOS DCIM What is the CenterOS

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

MEASURE MONITOR UNDERSTAND

MEASURE MONITOR UNDERSTAND MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration

More information

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS GLOBAL PRESENCE, LOCAL SERVICE WHERE WE MAKE IT WORK WHO WE MAKE IT WORK FOR ACCREDITATIONS i-chiller -10 C to 30 C 1.7 TO 505kW i-chiller COMPACT

More information

DAX Directional Airflow exhaust system. Energy efficient heat removal and redistribution. Product overview and technical data

DAX Directional Airflow exhaust system. Energy efficient heat removal and redistribution. Product overview and technical data DAX Directional Airflow exhaust system Energy efficient heat removal and redistribution incorporating technology Product overview and technical data Overview and principle DAX System - what is it? The

More information

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Variable Density, Closed-Loop, Water-Cooled Data Center Solution Variable Density, Closed-Loop, Water-Cooled Data Center Solution Overview Great Lakes Case & Cabinet Co., Inc. has worked with Naissus Thermal Management Solutions, of Toronto, Ontario to develop one of

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU

More information

Air Containment Design Choices and Considerations

Air Containment Design Choices and Considerations Air Containment Design Choices and Considerations Brad J. Murphy, A.Sc.T., ATS, DCDC, DCEP, Principal Racon Data Centres Introduction Introduction Air containment design must consider many different factors

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

FREEING HPC FROM THE DATACENTRE

FREEING HPC FROM THE DATACENTRE FREEING HPC FROM THE DATACENTRE ku:l sistem TM COOLING REDEFINED www.iceotope.com ku:l sistem removes the need for inefficient air cooling technologies FREEING HPC FROM THE DATACENTRE Iceotope s patented

More information

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center Precision Cooling For Business-Critical Continuity Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms Problem Several cooling system mistakes are very common and avoidable Mistakes compromise availability and increase

More information

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell

More information

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments COOLING SOLUTIONS SmartRack Close-Coupled Cooling for IT Environments Efficient, flexible, manageable cooling reduces costs and simplifies installation. Efficient, flexible, manageable cooling for IT environments

More information

Indirect Adiabatic and Evaporative Data Centre Cooling

Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

Google s Green Data Centers: Network POP Case Study

Google s Green Data Centers: Network POP Case Study Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice

More information

Indirect Adiabatic and Evaporative Data Center Cooling

Indirect Adiabatic and Evaporative Data Center Cooling Indirect Adiabatic and Evaporative Data Center Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced technology

More information

Ecotel Free Cool 5-15kW

Ecotel Free Cool 5-15kW Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component

More information

CL20 Rear Cooler Technical data metric

CL20 Rear Cooler Technical data metric New generation computer room cooling CL20 Rear Cooler Technical data metric CL20 Rear Cooler Product guide This document This is not a controlled document. Distributed copies will not be updated. This

More information

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES PROCESS & DATA CENTER COOLING How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES CONGRATULATIONS 2 BOLD PREDICTION 3 Where We Are TODAY Computer Technology NOW advances more

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

APC APPLICATION NOTE #146

APC APPLICATION NOTE #146 #146 Hot Aisle Containment Application Guidelines and Approved Configurations By Kevin Lemke Abstract The Hot Aisle Containment System (HACS) is a modular ceiling panel and door system for use in isolating

More information

HIGH DENSITY RACK COOLING CHOICES

HIGH DENSITY RACK COOLING CHOICES WATERCOOLED HIGH PERFORMANCE COMPUTING SYSTEMS AQUILA WHITE PAPER HIGH DENSITY RACK COOLING CHOICES by Phil Hughes Reprinted with permission of Clustered Systems Company, Inc 1 THIS WHITE PAPER DISCUSSES

More information

RE Series Rack from Eaton Product Presentation

RE Series Rack from Eaton Product Presentation RE Series Rack from Eaton Product Presentation AUG 2018 Quick Overview What is Eaton s RE Series Rack Platform? RE Series is an amalgamation of the NR & RE Series with many value-add component enhancements;

More information

Design and Installation Challenges: Aisle Containment Systems

Design and Installation Challenges: Aisle Containment Systems Design and Installation Challenges: Aisle Containment Systems 1 We all know the Benefits of Containment 1. Reduces Total Cost of Data Center Ownership 2. Eliminates hot spots 3. Supports higher heat and

More information

Power Monitoring in the Data Centre

Power Monitoring in the Data Centre Power Monitoring in the Data Centre Fixed or Wireless Steve Strange RCDD ANIXTER INTERNATIONAL Agenda Energy Consumption Case Study Reasons to Monitor Power Monitoring Environmental Monitoring Asset Tags

More information

Environmental Data Center Management and Monitoring

Environmental Data Center Management and Monitoring 1 Environmental Data Center Management and Monitoring A White Paper from aritan 2 Table of Contents Introduction... 3 Sensor Design Considerations... 3 Temperature and Humidity Sensors... 4 Airflow Sensor...5

More information

Cannon T4 Modular Data Center (MDC)

Cannon T4 Modular Data Center (MDC) SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4

More information

A Green Approach. Thermal

A Green Approach. Thermal A Green Approach to Thermal Management Thermal Management - AGENDA Definitions & Thermal Facts Density Trends Rack Level Management Passive Solutions Thermal Sources & Green Solutions Data Center Layout

More information

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Executive Summary As electricity prices and IT

More information

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42 Ten Cooling Solutions to Support High-density Server Deployment Schneider Electric Data Center Science Center White Paper #42 1 Introduction 2 Introduction This paper provides 10 approaches for increasing

More information

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach Proper airfl ow and thermal management are the most critical aspects of designing and operating your data center,

More information

Close Coupled Cooling for Datacentres

Close Coupled Cooling for Datacentres Close Coupled Cooling for Datacentres Dr Fathi Tarada Mosen Ltd fathi.tarada@mosenltd.com www.mosenltd.com Agenda Increasing Power Densities Raised Floor Limitations Hot and Cold Aisle Enclosures Close

More information

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Server Room & Data Centre Energy Efficiency. Technology Paper 003 Technology Paper 003 Server Room & Data Centre Energy Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile:

More information

Taking The Heat Off University of East Anglia Data Centre

Taking The Heat Off University of East Anglia Data Centre Taking The Heat Off University of East Anglia Data Centre University of East Anglia delivers data centre to match corporate green credentials The University of East Anglia (UEA) is one of the leading green

More information

18 th National Award for Excellence in Energy Management. July 27, 2017

18 th National Award for Excellence in Energy Management. July 27, 2017 18 th National Award for Excellence in Energy Management July 27, 2017 ICICI Bank, Data Centre, August Hyderabad 30 & 31, 2017 ICICI Bank - Revolution in Digital Banking Over 100,000 Digital POS in 4 months

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency

More information

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model Austin Data Center 6Sigma DC CFD Model Keith Ward Keith Ward Data Center Facilities Engineering and Logistics Design Austin Data Center Statistics - Space Original AT&T Designed and

More information

Running Your Data Center Under Ideal Temperature Conditions

Running Your Data Center Under Ideal Temperature Conditions TECHNICAL BRIEF Mastering Data Center Environmental Controls to Help Drive Your Bottom Line Running Your Data Center Under Ideal Temperature Conditions Challenge Many data centers waste energy using inefficient

More information

Data Center Energy Savings By the numbers

Data Center Energy Savings By the numbers Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained

More information

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group Data center cooling evolution. The hottest way to save energy Lucio Bustaffa: Product Development Manager BlueBox Group Data Center overview What s happening in the web? 2 Data Center overview What s happening

More information

WIRELESS ENVIRONMENTAL MONITORS

WIRELESS ENVIRONMENTAL MONITORS Packet Powers compact wireless Environmental Monitors makes it easy and affordable to monitor all environmental conditions in your facility. From installation to monitoring in minutes 1 Place wireless

More information

Green IT and Green DC

Green IT and Green DC Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental

More information

Introducing the Heat Wheel to the Data Center

Introducing the Heat Wheel to the Data Center Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique

More information

Case Study Host Europe Group

Case Study Host Europe Group Data Centre Solutions...energy efficient by design Case Study Host Europe Group Host Europe Creates Low Carbon 4MVA Managed Services Data Centre Facility Creating an effective workspace environment Host

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER Applications in Diverse Climates within Europe, Middle East and Africa Freecooling, Evaporative and Adiabatic Cooling Technologies

More information

Ten Cooling Solutions to Support High- Density Server Deployment

Ten Cooling Solutions to Support High- Density Server Deployment Ten Cooling Solutions to Support High- Density Server Deployment By Peter Hannaford White Paper #42 Revision 2 Executive Summary High-density servers offer a significant performance per watt benefit. However,

More information

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP This case study will evaluate the feasibility of data center free cooling in the Middle East using indirect

More information

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months TWO FINANCIAL IMPACT STUDIES Seal IT Equipment Cabinets for Significant

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities 2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits

More information

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA Smart Data Centres Robert M Pe, Data Centre Consultant Services SEA 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Content Data center

More information

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data White Paper EC9005A Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data Peer reviewed case study data from ASHRAE now updated with CFD model analysis revealing

More information

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE Best practices for airflow management and cooling optimisation DC ASSESSMENT SERVICES AISLE CONTAINMENT AIRFLOW MANAGEMENT Achieving true 24/7/365 operation

More information

Rittal Cooling Solutions A. Tropp

Rittal Cooling Solutions A. Tropp 1 Rittal Cooling Solutions Presented by Adam Tropp 2 Agenda Cooling Strategies Aisle Containment Chimney Solution Airstream Management Rittal Liquid Cooling Packages Data Monitoring 3 Cooling strategies.

More information

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels The use of a hot aisle/cold aisle configuration in the data center has long been considered a best practice

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information

Case Study The University of Warwick

Case Study The University of Warwick Data Centre Solutions...energy efficient by design Case Study The University of Warwick Workspace Technology deploys industry leading Indirect Fresh Air Cooling for the University of Warwick Workspace

More information

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary Datacenter Efficiency Trends Cary Roberts Tellme, a Microsoft Subsidiary Power Slashing Tools P3 Kill-A-WATT Measures min, max, and instantaneous voltage and current draw Calculates power (watts), kilowatt

More information

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 Ecolibrium OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001 Cloud control Keeping data centres cool. 22 ECOLIBRIUM OCTOBER 2018 The hunter and the prey A clever modernisation

More information

1.866.TRY.GLCC WeRackYourWorld.com

1.866.TRY.GLCC WeRackYourWorld.com cool it. 1.866.TRY.GLCC WeRackYourWorld.com In order to maximize space in the data center and accommodate for increased data, rack-mount enclosures are becoming populated with high-density servers and

More information

Data Center Airflow Management Basics: Comparing Containment Systems

Data Center Airflow Management Basics: Comparing Containment Systems WHITE PAPER Data Center Airflow Management Basics: Comparing Containment Systems Edited by David Knapp Product Marketing Manager Published: February 2017 US & Canada +1-800-834-4969 Toronto, Ontario, Canada

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day IT infrastructure Next level for data center Rittal The System Yavor Panayotov Data center Day - 2018 1 Rittal The System - Solutions Enclosures Enclosures Small enclosures Command Panel & support arm

More information

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks Liquid Cooling for Data Centers System Overview The Chilldyne Cool-Flo System is a direct-to-chip liquid cooling system that delivers coolant under negative pressure. Chilldyne s technologies were designed

More information

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Effectiveness and Implementation of Modular Containment in Existing Data Centers WHITE PAPER Effectiveness and Implementation of Modular Containment in Existing Data Centers By Lars Strong, P.E., Upsite Technologies, Inc. Bruce Long, Upsite Technologies, Inc. 505.798.0200 upsite.com

More information

Recapture Capacity for Existing. and Airflow Optimization

Recapture Capacity for Existing. and Airflow Optimization Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

Case Study Leicester City Council

Case Study Leicester City Council Data Centre Solutions...energy efficient by design Case Study Leicester City Council Leicester City Council Deploys New Sub 1.1 PUE3 Data Centre Infrastructure. Designed & Installed by Workspace Technology

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,

More information