The 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.
|
|
- Alban Flynn
- 5 years ago
- Views:
Transcription
1 Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over 0 years. They are used worldwide throughout the petroleum, petrochemical, chemical, pulp and paper, food and beverage and other industries where flame propagation is a potential problem. Varec s success in this area is based on its high standards for product design and manufacture. The 00A Series utilizes two principles to stop the propagation of flame from external sources. The first method is dissipation of heat. The temperature of the flame front is reduced below the flash point of the vapor by the absorption of heat through the surface of the bank assembly. The second method concerns the quenching diameter of Class D vapors. The space between the bank assembly crimps is smaller than the diameter required to pass a flame of a Class D gas. These units are generally used in conjunction with low flash point liquids and flammable gases or vapors. They should be installed vertically on tank vent systems or in piping headers up to a maximum of 0 pipe diameters upstream of the ignition source, when used in accordance with FM Approval, or feet when used in accordance with UL Approval. For distances or gas classifications outside these limits, the detonation arrester should be used. Proper application of flame arresters is crucial for plant safety. Varec applications engineers or factory trained representatives can assist you with your specific applications. Features The net free area through all Varec Flame Arrester banks is three to four times the unit pipe size. This design reduces surface friction, therefore, optimizing flow capacity and minimizing pressure drop. The large surface area of the bank also improves heat dissipation. Varec 00A Series s are designed with a spiral wound and crimped bank element. Maintenance of the bank assembly is simple: The tie rod bolts are removed and the remaining jackscrews expanded. This extends the end housings allowing the bank assembly to be easily removed. A handle is provided for easy handling. The bank element is quickly inspected or cleaned and replaced between the end housings. Technical data Three to four times net free area through bank UL and FM approved Rugged construction for extended life Unitized design with jackscrews for easy inspection and maintenance Broad range of materials available Flow Control Total Flow Control Solutions without notice. Copyright 00 by Tyco International Ltd. VRCMC-00-US-00
2 Varec 00A Series R Specifications Sizes,,,,, 0 and Connections Aluminum drilled to ANSI Class dimensions, flat face flange Steel and Stainless Steel drilled to ANSI Class 0 dimensions, raised face flange Pressure Rating Leak proof to 0 psi [.0 kpa] Pressure Drop Should not exceed psi [. kpa] Location Within feet [.m] upstream of flame source when used in accordance with UL Listing, or 0 pipe diameters when used in accordance with FM Approval Configuration Net Free Area Three to four times the corresponding size standard pipe Bank Assembly Spiral wound and crimped element with core housing and integral handle Housing Materials Heavy wall, HT low copper aluminum, standard Steel or stainless steel, optional Bank Assembly Material Low copper aluminum core housing and element, standard Low copper aluminum core housing with stainless steel element, optional All stainless steel core housing and element, optional Approvals UL (Underwriters Laboratories) listed in all aluminum construction in,, FM (Factory Mutual) All sizes, all materials Note. For use on hydrocarbon storage tanks, installed NOT MORE THAN FEET from the open end of the vent pipe when used in accordance with UL Listing or 0 pipe diameters when used in accordance with FM Approval. These test conditions may not represent the actual service conditions of piping system design. It is recommended that the arrester be independently tested under actual service conditions before installation. Dimensions, inches and pounds [millimeters and kilograms] H Ref W Ref L Ref W Ref, and Size Size Code 0 Nominal 0 Pipe Size [0] [0] [00] [0] [00] [0] [00] L Length H Height W Width Shipping Weight / / 0 / / / 0 / / [] [] [] [] [] [] [] / / / / 0 [] [] [] [] [] [] [] / / / [] [] [] [] [] [] [] [] [] [0] [] [] [] [] Notes Flange drilling per ANSI Class flat face flange (aluminum) or per ANSI Class 0 raised face flange (steel and SS). Installation, mounting arrangement and dimensions are preliminary information not to be used for construction. Certified drawings are available upon request. VRCMC-00 without notice. Copyright 00 by Tyco International Ltd.
3 Varec 00A Series Flow Curves 00A Series Pressure Vacuum Inches of Water Inches of Water Thousand cubic feet/hour at 0 F and. psia Air flow (SCFH) VRCMC-00 without notice. Copyright 00 by Tyco International Ltd.
4 Varec 00A Series Flow Curves 00B Series Relief Valve with 00A Series Set at 0. Inches of Water Pressure and Vacuum Pressure Vacuum Inches of Water Inches of Water Thousand cubic feet/hour at 0 F and. psia Air flow (SCFH) VRCMC-00 without notice. Copyright 00 by Tyco International Ltd.
5 Varec 00A Series Ordering Information Model 00A Description (Vertical Installation Only) Code Size (Select one) 0 0 Code Housing/Core/ Element Materials Aluminum/Aluminum/Aluminum Aluminum/ SS/ SS Carbon Steel/ SS/ SS Ductile Iron/ SS/ SS SS/ SS/ SS 00A (Example) (Example: with aluminum housing, aluminum core housing and element) VRCMC-00 without notice. Copyright 00 by Tyco International Ltd.
6 Varec 00A Series Stafford Facility Phone: --00 Tyco Valves & Controls The data presented in this bulletin is for general information only. Manufacturer is not responsible for acceptability of these products in relation to system requirements. Patents and Patents Pending in U.S. and foreign countries. All rights reserved. Printed in U.S.A. without notice. Copyright 00. VRCMC-00 without notice. Copyright 00 by Tyco International Ltd.
VAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More informationVAREC 5000/5010. Flame Arresters
VREC 000/00 The 000/00 Series end-of-line flame arresters are used in gas piping systems, petroleum storage tank roofs and digester covers to prevent the propagation of a flame into the system. INTROUCTION
More informationIntroduction. Available materials. Aluminum Carbon Steel Stainless Steel Ductile Iron Special Materials on Application
VALVES & CONTROLS VAREC 00B/00B The Varec 00B/00B protects tanks from damage or deformation, and minimizes emissions to the environment, as well as loss of product due to evaporation. Introduction 00B
More informationThe 221 Series is designed to provide emergency venting of low pressure storage tanks and vessels.
Varec Series The Series is designed to provide emergency venting of low pressure storage tanks and vessels. Introduction When the tank is exposed to abnormal internal pressure or vacuum beyond the capability
More informationVAREC 2010B/2020B PRESSURE AND VACUUM RELIEF VALVES
VAREC 0B/B PRESSURE AND VACUUM RELIEF VALVES Weight-loaded relief valves that protect tanks from damage or deformation, minimize emissions to the environment and loss of product due to evaporation FEATURES
More informationVAREC 221 SERIES EMERGENCY PRESSURE RELIEF MANWAY COVERS
VAREC SERIES EMERGENCY PRESSURE RELIEF MANWAY COVERS The Series is designed to provide emergency venting of low pressure storage tanks and vessels FEATURES P PV Available in emergency pressure only and
More informationSpecification. Radiamatic Detectors and Accessories
4/92 Page 1 of 8 Radiamatic Detectors and Accessories Specification Function The Radiamatic temperature detector generates an emf proportional to the temperature of the object sighted. It is used with
More information98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98
Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationRosemount 1595 Conditioning Orifice Plate
Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe
More informationButterfly Control Valve. DMK/6 Series
Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK
More informationACFD12-T ACFD12-B. Technical Data
TM ACFD12-T ACFD12-B Technical Data Contents Overview.................................................1 Scalable Solution for Critical Environments....................2 Standard Features.........................................5
More informationInstallation and Operating Manual FM50 IOM 2-18 DRAFT
Installation and Operating Manual Table of Contents 1. Safety Precautions... 3 2. Details 2.1 Part Numbers... 4 2.2 Configurations... 5 2.3 Specifications... 13 2.4 Cables and Wiring... 14 2.5 Interface,
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationUniversal IV Water Cut Meter
DREXELBROOK DATA SHEET Universal IV Water Cut Meter with Density Compensation Use the Best For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before
More informationModel VDL 115 Vacuum drying chambers for flammable solvents
Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber
More informationimag 4700 Series FLANGED MAGMETER
r (Remote Display) RIGHT METER FOR Water & Wastewater Treatment Municipal Pump skids Pump stations Packaged plants Filtration systems Reclaimed water Hydraulic fracturing Features Easy setup Minimal straight
More informationCommon grade: ASTM A36..min. 36,000 yield / min. 58,000 tensile. Size Weight (lbs.) Weight (lbs.)
Bar Size Angle Common grade: ASTM A36..min. 36,000 yield / min. 58,000 tensile Size Weight (lbs.) Weight (lbs.) A B C per Foot per 20' 1/2 x 1/2 x 1/8 0.38 7.6 5/8 x 5/8 x 1/8 0.48 9.6 3/4 x 3/4 x 1/8
More informationLevel Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog
Features Level Plus Liquid-Level Sensors With Temposonics Technology Floats, s and Accessories for Process Level and Tank Gauging Applications Accessories Catalog Variety of styles and sizes to fit most
More information1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil
More informationJunction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety
PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product
More informationATX JBEA and ECEA Series Aluminum Enclosures Increased Safety
Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG i M A G S e r i e s o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal
More informationPowers TM Controls RL 243 MP Multi-Purpose Relay
Powers TM Controls Technical Instructions Document No. 155-042P25 RL 243-6 Description The Powers is a pneumatic auxiliary device designed to provide a variety of pneumatic control functions for the typical
More informationGas-actuated thermometer Stainless steel version Model 73
Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology Accessories Catalog SENSORS Document 551103 Revision C Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming
More informationYour Clean Air Source!
In-Line Centrifugal Fans Your Clean Air Source! CENTRIFAN IN-LINE CENTRIFUGAL FAN HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY CENTRIFAN IN-LINE CENTRIFUGAL FANS INDEX Centrifan Brochure Index..................
More informationOil & Gas. Control Control. every move. Pressure Temperature Level Flow
Oil & Gas Control Control every move Pressure Temperature Level Flow Barksdale Oil and Gas - The Challenge today Oil & Gas Today Worldwide economic growth, depletion of oil reserves, and continued investment
More informationimag 4700 Series FLANGED MAGMETER
p r (Remote Display) RIGHT METER FOR Water & Wastewater Treatment Municipal Pump skids Pump stations Packaged plants Filtration systems Reclaimed water Hydraulic fracturing -300 Features Easy setup Minimal
More informationModel VD 23 Vacuum drying chambers for non-flammable solvents
Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology
More informationimag-series Flanged Magmeter
s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO
More informationOur Know-How. Your Peace of Mind. Expansion Joint Solutions
Our Know-How. Your Peace of Mind. Expansion Joint Solutions ERIKS Offers an Unmatched Suite of Value Added Expansion Joint Services Design and engineering consulting and manufacturing Emergency support
More informationHouston Digital Instruments, Inc. Product Catalog
Houston Digital Instruments, Inc. Product Catalog 2000B-Low Cost 2400-Custom Options 3300-Temperature 2100-Stroke Counter (1-4) 2200-Position Indicator 2000P-Parking Meter Issue date: September 29, 2003
More informationJunction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety
CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC
More informationAmerican Society of Sanitary Engineering Seal (Certification) Program
American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Water Hammer Arresters Tested under ASSE Standard 1010 Revised: February, 2004 Laboratory File Number
More informationNorth US 290 US 183. MLK Blvd. FM 969. ASERO Steel Sales. Ben White TX 71 IH-35 US 183
North US 290 US 8 MLK Blvd. FM 969 ASERO Steel Sales Ben White TX IH- US 8 Hot Rolled Strip Commercial Quality A - 0 Size in Per 20 Ft. /8 x /2.2 4.26 /4.9 6.8.42 8.0 /4. 0.62 /2.68 2.6 2.80.00 2 /2.06
More informationRosemount 1595 Conditioning Orifice Plate
Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationzqsfp+ Behind Bezel Cage Assembly, Heat Sink, and Light Pipe
zqsfp+ Behind Bezel Cage Assembly, Heat Sink, and Light Pipe Application Specification 114-32023 02 MAR 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions
More informationEJB Junction Boxes Dimensions Pg. 132
6F EJB Junction Boxes Dimensions Pg. 132 Application: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG imag Series o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved
More informationTILBURY STEEL SERVICE CENTRE
TILBURY STEEL SERVICE CENTRE 159 Queen Street North Tilbury, ON, N0P 2L0 Voice: 519-682-0000 Toll-Free: 1-800-565-1077 Fax: 519-682-0004 Email: tsales@tilburysteel.com STOCK BOOK & REFERENCE GUIDE Tilbury
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model USTD II Underground Storage Tank Level Sensing for Leak Detection and Inventory Monitoring FEATURES DDA Output
More informationSeries DMHF Heat Meter
Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement
More information1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationMCG 1500SFI. MCG 1500SFI Smart Flash Infrared Servo Gauge. Features. Smart Flash Infrared Servo Gauge
Brushless Design Eliminates Moving Parts With only 3 moving parts (drum assembly, gear assembly, and stepper motor) and only two PC boards (the CPU and the strain gauge amplifier), L&J has minimized parts
More informationFeatures: Quality Testing and Documentation
1 The Yokogawa Falcon Series Dual Chamber Orifice Assembly YFOM-DC, is suitably designed for on-line retraction and inspection of orifice plates in process full flow and pressure conditions. The orifice
More informationRosemount 1595 Conditioning Orifice Plate
Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe
More informationContender LED Luminaires Enclosed and Gasketed Fixtures
Class I, Division, Groups A,B,C,D Class I, Zone, Group IIC Class II, Division, Groups E,F,G Zone and, Group IIIC Class II, Division, Groups F,G Type R, 4, 4X Applications Enclosed and gasketed fixtures
More informationLevel Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology
Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103
More informationDREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance
USE THE BEST For over 50 years, Drexelbrook has been the world s leader in capacitive based measurements by providing reliable and accurate products at a reasonable cost. We offer the highest pressure
More informationMAG. ECO FLO imag Series NSF FEATURES
Flow Meters & Controls MAG ECO FLO imag Series M o vi n g P s N o rt w U NSF o n Easy setup Minimal straight pipe Mounted or remote rate & total 4-2mA output available Tamper-evident seal NSF-61 approved
More informationUW Purchase Specification Section Central Cooling Water Meter Page 1 of 6
Page 1 of 6 PART 1 GENERAL 1.01 DESCRIPTION A. Purpose 1. This section covers central cooling water meters for use in the Owner's central cooling water systems. 1.02 QUALIFICATIONS A. Approved manufacturers
More informationModel 243 Service Regulators. R-1306 Rev. 10
Model 4 Service Regulators R06 Rev. 4 Service Regulators These large capacity service regulators are designed and built for commercial, industrial and gas distribution work. They are right at home in such
More informationAMP-HDI* Connectors. Solder Tail. Keying Hole Keying Hole. Vertical Pin Assembly. Figure 1
AMP-HDI* Connectors Application Specification 114-9008 24 APR 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and
More informationType 330SA High-Performance Electric Actuator
April 2000 Bulletin 61.5:330SA Type 330SA High-Performance Electric Actuator The Type 330SA High-Performance Electric Actuator (figure 1) is a high speed, high accuracy actuator that is suited for a wide
More informationSono-Trak Transit Time Clamp-on Ultrasonic Flow Meter
A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationTechnical Data. Care and Maintenance
Worldwide Contacts www.tyco-fire.com GRINNELL G-FIRE Grooved Fittings, Ductile Iron General Description GRINNELL G-FIRE Grooved Fittings provide an economical and efficient method of changing direction,
More informationshop online:
Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid
More informationred-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection
red-y industrial series product information Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection High accuracy for heavy duties: Mass Flow Meters & Controllers with IP67 & Ex Protection
More informationRATIO CONTROLLER HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION NOTE DESCRIPTION SPECIFICATION
RATIO CONTROLLER TECHNICAL DATA MODEL SIZE MAX. SERVICE PRESSURE FACTORY HYDRO TEST PRESSURE MOUNTING APPROVAL FINISH ORDERING INFORMATION DESCRIPTION Bronze Construction:- RCW-B, RCW-BM RCF-B, RCF-BM
More informationMicro Motion R-Series General Purpose Mass and Volume Flowmeter
Product Data Sheet PS 00363 February 2002 Micro Motion R-Series General Purpose Mass and Volume Flowmeter Now available with MVD Technology TYPE EL OCTOBER 2001 www.micromotion.com Micro Motion R-Series
More informationQVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes
s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature
More informationExplosion Proof Junction Box - C1D1, C2D1 - (6) Circuit Terminal Strip - (6) Hubs - Backplate
Explosion Proof Junction Box - C1D1, C2D1 - (6) Circuit Terminal Strip - (6) Hubs - Backplate Part #: EPJ-6-TB The Larson Electronics EPJ-6-TB Explosion Proof Junction Box is designed for flammable work
More informationGOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved
GOLDENI 600 model# GOLDi600 English Copyright 2017 Smart Grow Technologies, INC All Rights Reserved Owners Manual & Safety Instructions INTRODUCTION This User Manual is for Smart Grow Technologies (SGS):
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationTechnical data: Pin Spacing
282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,
More informationSpectrum 130D. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register Standards AWWA C NSF-61/372
The Spectrum Single-Jet Meter is the widest range, single measuring element meter available to U.S. utilities. They have been designed to replace limited range displacement meters. The Spectrum meters
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationSeries 062 Bus Bar Connectors
Series 062 Bus Bar Connectors Application Specification 114-2130 22 DEC 11 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation
More informationList of forms CLAP/WGP by subject /68/UE
List of forms CLAP/WGP by subject - 2014/68/UE Subject Assembly - Assembly including an item of pressure equipment placed on the market before 29 May 2002 in compliance with national pre-ped regulations
More informationSpectrum 175D. meter performance with no maintenance.
The Spectrum Single-Jet Meter is the widest range, single measuring element meter available to U.S. utilities. They have been designed to replace maintenance-intensive compound meters and limited range
More informationTable of Contents: Pressure Vessel Codes & Registrations: Manufacturing Capabilities: Engineering Capabilities: Paint Specifications:
Pressure Vessel Codes & Registrations: The items listed in this catalog have been designed and constructed in accordance with the ASME Section VIII Division I Code latest edition and are registered with
More informationRosemount 1595 Conditioning Orifice Plate
Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before working with the product.
More informationLevel Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology. Liquid-Level Transmitter Accessories Catalog
Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology Liquid-Level Transmitter Accessories Catalog TABLE OF CONTENTS Accessories Overview...3 Floats Standard Floats...4.Standard
More informationPreparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder
GEP-7004 Rev. L 101251 Ref. ID: 5472 Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder WARNING USER SHOULD
More informationTechnical Data. Care and Maintenance
Worldwide Contacts www.tyco-fire.com GRINNELL G-FIRE Grooved Fittings, Ductile Iron General Description GRINNELL G-FIRE Grooved Fittings provide an economical and efficient method of changing direction,
More informationCONCEPT Stainless Steel Wall-Mount Enclosures
CONCEPT Stainless Steel Wall-Mount Finish are unpainted. Door and body have smooth #4 brushed finish. Optional CONCEPT panels are white painted or zinc-plated. Optional NEMA panels are white painted, zinc-plated,
More informationFloat switch For the process industry, lateral installation with external chamber Model ELS
Level measurement Float switch For the process industry, lateral installation with external chamber Model ELS KSR data sheet LM 30.03 for further approvals see page 2 Applications Mounting on engines,
More informationChris Christopoulos, Jr.
Portable Pipelines for First Responders Portable Pipeline Sometimes called a Virtual Pipeline, is method for supplying natural gas to areas not serviced by a traditional pipeline. Chris Christopoulos,
More informationLevel sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H
Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement
More informationAG3000 SERIES FLANGED MAGMETER
SERIES p Precision Flow Measurement An ONICON Brand RIGHT METER FOR Irrigation Chemigation Agricultural automation Well usage monitoring Dairy lagoons Features 5 5-YEAR WARRANTY LONGEST IN THE IRRIGATION
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match
More informationMicro Motion R-Series Mass and Volume Flowmeter
Product Data Sheet PS-363, Rev. B March 24 Micro Motion R-Series Mass and Volume Flowmeter With MVD Technology TM Micro Motion Micro Motion R-Series Flowmeters Welcome to a new era in measurement technology!
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open
More informationFurnace Camera System Operator s Manual. Version
Furnace Camera System Operator s Manual Version 12-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Specifications... 3 2.3 Confirmation of Camera Field of View...
More informationComposite Type Rupture Disc
Composite Type Rupture Disc 2-2202-2 COMPOSITE* TYPE RUPTURE DISC What is a Composite Type Rupture Disc? A Composite Type Rupture Disc is a differential pressure relief device used to protect pressurized
More informationCLAMSHELL PIPE CUTTING AND BEVELLING MACHINES. Mactech Europe LTD
CLAMSHELL PIPE CUTTING AND BEVELLING MACHINES Mactech Europe LTD Mactech s Clamshell lathes are portable pipe cutting machines designed for on-site precision severing, severing/beveling, and severing/double
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More information