Wall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control
|
|
- Doreen Maxwell
- 5 years ago
- Views:
Transcription
1 Wall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control Code SATK DPCV ACCRDITD 04/ B ISO 900 FM 64 ISO 900 No. 000 Function The latest generation of mechanical heat interface units, SATK independently controls the heating and domestic hot water production in an individual apartment within a centralized boiler or district heating system. SATK DPCV is an high temperature wall-mounted HIU for instantaneous production of domestic hot water with a mechanical control and a kpa differential pressure control valve. Technical specifications Dimensions (mm) Medium: water, max. % glycol Max. medium temperature: 8 Max. pressure: - Primary circuit: PN 6 bar - Domestic hot water circuit: PN 6 bar Domestic hot water exchanger capacity: 40 kw Domestic hot water flow rate: min.,8 ± 0, l/min Max. differential pressure: bar Differential pressure fixed setting: kpa (0, bar) M N L Materials Frame: xchanger: Connection pipes: Components: Weight: steel plate brazed copper brass N6 CW67N 6, Kg C D H I F B F B A A 4 7 B 90 H 0 C 0 I 0 D 4 L 7 /4 M F 70 N 78 Characteristic components Domestic hot water differential pressure priority valve - Manual air vent - 40 kw brazed exchanger 4 - Mechanical modulating valve with manual pre-set - DPCV (differential pressure control valve) 6 - Strainer The priority valve () gives priority to the production of domestic hot water when there s a differential of pressure on sanitary circuit. During the production of domestic hot water the modulating valve (4), with a manual preregulation on it, controls the primary flow rate according to the requested domestic hot water flow rate. Heating circuit is always on when there s no request of domestic hot water, it s recommended to provide a zone or thermostatic valve with it. Before installation it s recommended to carry out accurate flushing of the pipes of the system in order to remove any residue or impurities that could endanger correct operation of the HIU. It s recommended to provide a strainer on primary flow. If water has a hardness level higher than F, a softening treatment is compulsory.
2 SATK DPCV domestic hot water preregulation settings SATK DPCV mechanical regulation allows to set the required domestic hot water temperature according to primary flow temperature, turning the black handle (A). Handle regulation, from a value (corresponding to open valve), to a value (corresponding to a closed valve), allows to set DHW temperature in a range. The range can change when primary supply temperature changes. raphics below can help during DHW pre-regulation operations, always related to primary supply temperature. N.B. SATK DPCV correct regulation is guaranteed only with primary constant supply flow temperature. A Regulation handle number of turns: Supply flow temperature 60 DCW inlet 0,0 0,0 4,0,0,0 0,0 4,0,0 0,0,,0 7, 0,0, 7,,0,0 Supply flow temperature 6 DCW inlet 0,0 0,0,,0 7, 0,0, 7,,0,0 0,0 4,0,0,0 0,0 4,0,0 0,0,,0 7, 0,0, 7,,0,0,0 0,0,,0 7, 0,0, 7,,0,0 0,0 4,0,0,0 0,0 4,0,0 0,0,,0 7, 0,0, 7,,0,0
3 Supply flow temperature 70 DCW inlet 0,0 0,0 4,0,0,0 0,0,,0 7, 0,0, 7,,0 Supply flow temperature 7 DCW inlet 0,0 0,0 4,0,0,0 0,0,,0 7, 0,0, 7,,0 Supply flow temperature 80 DCW inlet 0,0 0,0 4,0,0,0 0,0,,0 7, 0,0, 7,,0
4 SATK DPCV domestic hot water flow rate/primary flow rate performance (l/h) Primary flow rate ,, 7, 0,0,,0 7,,0 Primary return temperature Preregulation handle totally open (),0 Primary return temperature,0,0,0 0,0,0 0,0,,0 7, 0,0, 7,,0 Preregulation handle totally closed (),0 Primary return temperature,0,0,0 0,0,0 0,0,,0 7, 0,0, 7,,0
5 Hydraulic characteristics 0 Heating function p (kpa) , 00 0, 0, 00 p (kpa) , 0, 0, Domestic function - primary circuit Kv =,9 m /h Kv =,9 m /h Kv =,9 m (l/h) /h Kv =,4 m /h (l/h) (l/h) Kv =,4 m /h Kv =,4 m (l/h) /h (l/h) (l/h) Domestic function - secondary circuit p (kpa) , 00 0, 0, Kv = 0,9 m /h Kv = 0,9 m /h Kv = 0,9 m (l/h) /h (l/h) (l/h)
6 Differential pressure control valve Differential pressure regulating valves control the differential pressure, according to a fixed calibration value set by the producer: kpa. The best application for this type of valves is zone type installation, because it does not require any calibrating operation and it is not possible to alter their setting. The normal fixed calibration values are able to guarantee adequate pressures with a correct functioning of the zone derivations with thermostatic valves. Contrast spring High pressure plug cod Diaphragm Obturator Differential pressure regulating valve with fixed calibration Installation diagram HAT PUMP BOILR DCW SPCIFICATION SUMMARY Code SATK DPCV Wall-hanging, two-way heat interface unit for high temperature heating with instantaneous domestic hot water production, including: domestic hot water differential pressure priority valve, mechanical modulating valve with manual pre-set, plate heat exchanger, manual air vent, strainer, dimensions 4x0x. Medium: water Maximum percentage of glycol: %. Maximum medium temperature 8. Maximum working pressure: primary circuit 6 bar, domestic circuit 6 bar. Nominal DHW exchanger capacity: 40 kw. Maximum flow rate DHW circuit: 8 l/min. Minimum flow to activate the mechanical diverting valve:,8 ± 0, l/min. Maximum differential pressure: bar. Materials components: brass N6 CW67N. Connection pipes: copper. We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 800 Fontaneto d Agogna (NO) Italy Tel Fax info@caleffi.com Copyright Caleffi
Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems
6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN
More informationRadiator Lockshield Valves ADN.. AEN..
07 EN - Straight version ADN.. Angle version AEN.. ACVATIX TM Radiator Lockshield Valves ADN.. AEN.. for -pipe heating systems Valve bodies made of brass, mat nickel-plated DN 0, DN and DN 0 Integrated
More information2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET
-PORT SEAT VALVES PN WITH FLANGED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In boiler, district heating and refrigeration plants, cooling towers, heating groups, in ventilation and air-handling units as
More information3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET
-PORT SEAT VALVES PN WITH EXTERNALLY THREADED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In small or medium-sized heating, ventilating and air conditioning plants as a control or safety shutoff valve. For
More informationSpare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7
Spare part catalogue 0020037555.03 GB 03/2007 Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Content General view of sheet Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing
More informationTech Data. Brass Manifold Kit TECHNICAL FEATURES MATERIALS
Tech Data Brass Manifold Kit Kits are distribution systems consisting of delivery and return manifolds with built-in mounting brackets for an easy housing into the box. Delivery manifolds feature flow
More informationLockshield valves Series 195UM - 196UM 1195UM UM
Lockshield valves Series 9UM - 96UM 9UM - 96UM Main features - vailable in the following versions : ngle body, straight body, for iron, copper and polyethylene piping with / connection to radiator and
More informationSafety valves. Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50
Safety valves Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50 IMI PNEUMATEX / Accessories and Service / Safety valves Safety valves For the safeguarding of thermostatically
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationA 602 A B C. dynamx flow-control valves, series DXN6_B. Dynamic Flow Networking. Description. Content
602 dynamx flow-control valves, series DXN6_ For 4-pipes climate ceilings with change-over Pressure independent variable flow-control Integrated flow measurement Power supply U v : /D 24Volt Flow setpoint
More informationB 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content
DXM2D032 dynamx variable flow-control valves, series DXM_ 2-port or 3-port flow control valves Pressure-independent variable flow-control Integrated flow & temperature measurement Power supply U v : 24Volt
More informationA 101 A B C. Variable flow-control valve, series DXC. Dynamic Flow Networking. Description. Content
101 DX Variable flow-control valve, series DX Pressure independent variable flow-control Dynamic hydronic balancing in full load and part load Integrated flow and temperature measurement Power supply U
More informationPressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI
Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve ARI-PREDU - ANSI Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling
More informationBalancing valve PN 16 and PN 25 DN
STAF, STAF-SG Balancing valve PN and PN DN 0-00 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing
More informationElectromotoric actuator
Acvatix Electromotoric actuator SUA21/3 For zone valves AC 230 V operating voltage, 2-position control signal Positioning force 170 N Direct mounting with M30 x 1.5 union nut (no tools required) 3-wire
More informationFxM. ISO7/1 thread, EN331 standard PN40~PN25(5MOP/20MOP) Size:1/4 ~2
BA VAVE - EVER ANDE F/F Model: E0 Advantica british gas, wras, en approved ball valves yellow stainless steel lever handle; FxF ISO/ thread, EN standard PN0~PN(MOP/0MOP) Size:/ ~ According to EN standard.
More informationJaga-Deco Pro thermostatic valves
Valves Range Jaga-Deco manual valves Jaga-Deco Pro thermostatic valves Jaga-Deco thermostatic valves for single point connection - manual chrome-plated valve for connection to the wall or to the floor
More informationQVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes
s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature
More informationPressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI
Pressure reducing valve in straightway form NPS 1-6 Pressure reducing valve Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling diaphragm Cast steel Fig. 701 Page
More informationBelimo ZoneTight TM QCV 2-way characterised control valves and 3-way change-over ball valves. Table of Contents. Notes for project planning
Belimo ZoneTight TM QCV -way characterised control valves and -way change-over ball valves Table of Contents Introduction Type key Product features Adjustable angle of rotation k v setting Adaption Operating
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationEverything under control
SAMSON Everything under control SAMSON building automation Ready-configured user interfaces support the user during start-up as well as provide powerful features to control and monitor building facilities.
More informationPlumbing Brass Specification Guide
Plumbing Brass Specification Guide www.wattscanada.ca The Dial-ese Cartridge, a Standard in Canadian Plumbing for 0 Years Since its conception in the early 0s, the Dial-ese cartridge has proven to be one
More informationM3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems
MP..G/A, MP..F/A Modulating control valves (PN) for chilled and hot water systems Three-way or straight-through valves with magnetic actuators for modulating control of chilled and hot water systems. Short
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More informationUPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps
VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline
More informationBetacom c 24 and 30kW Combination Boilers
Betacom c 24 and 30kW ombination Boilers Betacom c 24 30kW Betacom c - ombination Boilers The new Glow-worm Betacom c range of high efficiency combi boilers is simple, affordable and reliable. This stylishly
More information2/2 VALVES FOR WATER. Water 2 WAY VALVES. Actuation Body Function Specification Port
The Parker 2 way valves (1 way for inlet and 1 way for outlet) for water and neutral liquids are optimized constructions for liquids handling. The exclusive diaphragm design gives a superior flow rate
More informationAIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS
RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.
More information6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination
More information7-day room temperature controller
s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large
More informationGB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series
GB MIX COMUNICAZIONE MI Digital Electropneumatic Regulator Series N E W w w w. c a m o z z i. c o m Digital Electropneumatic Regulator Series Port G/ SPECIFICATIONS XXX SPECIFICATIONS XXX ITEM // X P X
More informationSECTION THERMAL UTILITY METERING INTERFACE
SECTION 25 33 13 THERMAL UTILITY METERING INTERFACE GENERAL 1.1 SUMMARY A. Section includes metering and monitoring for interface points for utility chilled water, hot water, and steam fed to each building,
More informationElectrical Actuators
4 891 SSB without auxiliary switch SSB1 with auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB31 SSB81 SSB61 SSB31 operating voltage AC 230
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More informationPowers TM Controls RL 243 MP Multi-Purpose Relay
Powers TM Controls Technical Instructions Document No. 155-042P25 RL 243-6 Description The Powers is a pneumatic auxiliary device designed to provide a variety of pneumatic control functions for the typical
More informationHERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215
HERZ STRÖMAX 7GM/GML/GR HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0 H Rp L SW L L Dimensions in mm
More information4-step Chiller and Heat Pump Controller
4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW
More informationElectric Actuators with Process Controllers
Electric Actuators with Process Controllers TROVIS 5724-8 (without fail-safe action) TROVIS 5725-8 (with fail-safe action) For heating and cooling applications Application Electric actuators with integrated
More informationVAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More informationEW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS
Design EW7730K1200 qi: 0.015m 3 /h qp: 1.5m 3 /h qs: 3m 3 /h O: 5...130 C DN: 15 IP 54 PN: 16 Typ: 773 77300000 T.sensor: Pt 500 O: 0...180 C O: 3...177K Environm. class: E1 Mechanical class: M1 Metrological
More informationFOX-50 Heat Flow Meter
FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More information26360, NAMUR. Technical data
66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual
More informationInstallation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*
System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationDDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear
I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is
More informationRoom Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor
3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation
More information3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationNOVAZONE BALL MOTOR-DRIVEN BALL VALVE ADVANTAGES. Control of volume flows for different fluids in HVAC systems SYSTEM/BASIC DIAGRAM
OVAZOE BA OTOR-DRIVE BA VAVE ADVATAGES ovazone Ball up to " One potential-free auxiliary switch Short actuating times ever for manual operation ow maintenance -way with inversion of direction of operation
More informationG 1/2 30,5 A Brass NBR 0,8 3,
4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see
More informationSTAF, STAF-SG, STAF-R, STAG
STAF, STAFSG, STAFR, STAG Balancing valves 0. Technical description Applications: STAF, STAFSG, STAG: Heating and cooling systems STAFR: Heating and cooling systems Tapwater systems Functions: Balancing
More information98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES
The Transit Time Flow Meter of TTFM100 NEW GENERATION (NG) series measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This
More informationBELIMO ENERGY VALVE. Transparent energy monitoring with the Belimo Cloud.
BELIMO ENERGY VALVE TM Transparent energy monitoring with the Belimo Cloud. Know where the energy is going. The Belimo Energy Valve TM, which consists of a 2-way characterised control valve, volumetric
More informationCreate idrawnics enabled SketchUp components with Stick and Flip Data Plates Catalog Lookup Customizable Time and Materials
Create idrawnics enabled SketchUp components with Stick and Flip Data Plates Catalog Lookup Customizable Time and Materials draw a part in SketchUp 1:1 scale add a mating surface layer add a snap point
More informationM-Bus Pulse Collector Twin-Pulse Instruction Manual
M-Bus Pulse Collector Twin-Pulse Instruction Manual Rev. 1 10/13 Maddalena S.p.A. Via G.B. Maddalena 2/4 33040 Povoletto (UD) Italy Tel.: +39 0432/634811 Fax Export Dept.: +39 0432/679820 E-mail: info@maddalena.it
More informationRSK. Wafer Type Check Valve. Construction. Features. Advantages
Wafer Type Check Valve Construction The GEMÜ wafer type check valve is available in plastic or metal and the body, disc and seal can be chosen from various materials. The valve is clamped between two flanges
More informationCF series water cooled
Sheet 1 Job SP02U Inverter for stirrer application, Brochure 01 C 30.06.16 Water quality data Carnevale Quintiliani Pietrantonio 00 C 06.06.16 Issue Carnevale Quintiliani Pietrantonio Rev. File Date Revision
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Exploration Drive Aberdeen Science and Energy Park Aberdeen AB23 8HZ Contact: Mr Graham Robertson Tel: +44(0)1224 708500 Fax: +44(0)1224 772
More informationElectrical Actuators
4 891 SSB without auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB1 with auxiliary switch SSB31 SSB61 SSB81 SSB31 operating voltage AC 230
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationHeating Circuit Controller
2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation
More information1/7. Field settings table [6.8.2] =... ID66F2 / ID66F3. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes 4P E
/7 [6.8.] =... ID66F / ID66F3 Applicable indoor units *GSQHS8AA9W ThermaliaC* Notes /7 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step: A.3..4 C 7.4.. Eco (heating)
More informationElectromotive actuators for combi valves
s 4 833 ACVATIX Electromotive actuators for combi valves For combi valves VPF43.. and VPF53.. SQV..P.. SQV91.. Operating voltage AC/DC 24 V, Positioning signal 3-position, DC 0-10 V, DC 4-20 ma Position
More informationHERION SERIES Indirect solenoid actuated spool valves
HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free
More informationPrecision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers
Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited
More informationAutomation System TROVIS 5400 District Heating Controller TROVIS 5476
Automation System TROVIS 5400 District Heating Controller TROVIS 5476 On-off or three-step controller designed for wall or panel mounting (dimensions of front frame: 44 mm x 96 mm) Application Self-optimizing,
More informationCHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51
CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP
More informationMechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems
Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationEMP1 OPERATING & INSTALLATION INSTRUCTIONS
468 Liberty Drive Wittenberg, WI 54499 U.S.A. Tel: 715-253-2801 Ver.11-01-2008 Fax: 715-253-2811 Web: www.solar.imcinstruments.com REV. 5-15-10 EMP1 OPERATING & INSTALLATION INSTRUCTIONS EMP1-0200 PILOT
More informationDRI. VARIZON Displacement unit with adjustable spread pattern
VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install
More informationThermal Mass Flowmeter Sensyflow FMT200-D
Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring
More informationPressure switches and thermostats, types KP and KPI
Features Wide regulating range Small dimensions Space-saving - easy to install in panels Ultra-short bounce time. Limits wear to an absolute minimum and increases reliability. Electrical connection at
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match
More informationQuick Start Installation and User Manual
1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings
More informationElectromotoric actuators
4 861 ACVATIX Electromotoric actuators for Combi-valve types VPI45.., DN15 32 SSD31.. SSD81.. SSD61.. SSD31.. operating voltage AC 230 V 3-position control signal SSD81.. operating voltage AC 24 V 3-position
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing
More informationFlow VA 500/
VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety
More informationThermal Diffusivity Instruments DLF-2 with EM-1600
Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...
More informationPS600 series For viscous media or contamination
PS600 series For viscous media or contamination The PS600 series operates with a frontflush mounted diaphragm seal. Pressure applied on the stainless steel diaphragm is transmitted via the filling medium
More informationFPS SERIES Super Slim Ceiling Mount Air Handling Units
About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning
More informationKirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water
Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing
More informationHeating Circuit Controller
2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility
More informationMounting and Operating Instructions EB EN. Differential Pressure Meter Media 6 with LCD Media 6 with LED LED
Differential Pressure Meter Media 6 with LCD Media 6 with LED LED Media 6 with LCD and attached valve block (left), Media 6 with LED (right) Mounting and Operating Instructions EB 9527-1 EN Firmware A
More informationButterfly Control Valve. DMK/6 Series
Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK
More informationTemperature sensors and accessories for heat and cooling measurement points
Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationRVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting
G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationQ-Flow product information. Variable area flowmeters for gases and liquids
Q-Flow product information Variable area flowmeters for gases and liquids MyScale Air mm ALU Attractive design and price: Variable area flowmeters Q-Flow The proven variable area flowmeter with compact,
More informationProducts no longer available
echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationTECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM. G Rajabaskaran Vice Chairman
TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM 1 G Rajabaskaran Vice Chairman Nagman is an ISO 90001:2008 certified company and serving the global market since 1972 Our calibration lab is accredited
More informationSC3.6 differential controller 6 inputs, 4 outputs (3 relays, 1 potential-free switch output)
SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO- SOLAIRE THERMIQUE - SOLARE TERMICO EN SC3.6 differential controller 6 inputs, 4 outputs (3 relays, 1 potential-free switch output) Installation and Operation
More informationDouble solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100
Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 5 - DN 00 7. Printed in Germany Edition 0. Nr. Technical Description The DUNGS multiple actuator
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More information