Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Size: px
Start display at page:

Download "Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed."

Transcription

1 THE WALL-MOUNT AIR CONDITIONER.0 EER, (HZ) Models JAA to J72AA Right-ide Control Panel Models JLA to J72LA Left-ide Control Panel. to Ton (7,000 to 7,000 Btuh) The olair Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Green Refrigerant R-A Engineered Features Aluminum Finned Copper s: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Air Conditioner Compressor: croll Compressors eliminate need for crankcase heater. tandard on all models, except -Ton. R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and EPA requirements. Phase Rotation Monitor: tandard on all 3-phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 00 hours of salt spray tests per ATM B7-03. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. Filter ervice Door: eparate service door provides easy access for filter change. Two Inch, MERV Pleated Air Filters: Are standard equipment. Factory or field installed. Condenser Fan and Motor hroud Assembly: lides out for easy access. Barometric Fresh Air Damper: tandard on all units. Allows up to 2% outside fresh air. Optional ventilation packages available. Optional Circuit Breakers: tandard on all electric heat versions of single (2/ volt) and three phase (2/ volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase ( volt) equipment. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. Freezestat: tandard on W72 models. Optional field installed CMC-2 can be used on all other models. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in offdelay timer adjustable from seconds to minutes. 2-minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure witches are Auto- Reset: tandard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Complies with efficiency requirements of AHRAE/IENA Certified to ANI/ARI tandard for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL /CA 22.2 No. 23-0, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. - upersedes - Page of 2

2 Capacity and Efficiency Ratings Models JAA JLA J2AA J2LA JAA JLA Cooling Capacity BTUH 7,000 2,0,000 3,00,0,000,000 7,000 EER J3AA J3LA Capacity is certified in accordance with ANI/ARI tandard EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard All ratings based on fresh air intake being 0% closed (no outside air introduction). J2AA J2LA JAA JLA JAA JLA J72AA J72LA pecifications -/2 Ton through 3 Ton MODEL JAA-A JLA-A J2AA-A J2LA-A J2AA-B J2LA-B J2AA-C J2LA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C J3AA-A J3LA-A J3AA-B J3LA-B J3AA-C J3LA-C Electrical Rating Hz 2/ - 2/ - 2/ / - 2/ / - 2/ Operating Voltage Range Compressor--Circuit A Voltage 2/ 2/ 2/ 2/ 2/ 2/ 2/ Rated Load Amps.0/..2/..0/..3./2.0./ /./.. Branch Circuit election Current Lock Rotor Amps / / / 2 77/77 7/7 3 2/2 / Compressor Type croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 Fan Motor--Amps Fan--DIA/CFM " - 00 " - 00 " - 00 " - 00 " " " " - 20 " - 20 " - 20 Blower Motor & Evap. Blower Motor--HP-RPM-PD /-0-2 /-0- /-0- /-0- /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 /3-0-2 Blower Motor--Amps CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. x2x x2x x2x x2x xx xx xx xx xx xx hipping Weight --LB Barometric Fresh Air Damper-Lbs Economizer-Lbs pecifications 3-/2 Ton through Ton MODEL J2AA-A J2LA-A J2AA-B J2LA-B J2AA-C J2LA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C JAA-A JLA-A JAA-B JLA-B JAA-C JLA-C J72AA-A J72LA-A J72AA-B J72LA-B Electrical Rating Hz 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 J72AA-C J72LA-C Operating Voltage Range Compressor--Circuit A Voltage 2/ 2/ 2/ 2/ 2/ 2/ 2/ 2/ Rated Load Amps./../ /../ / / /../.. Branch Circuit election Current Lock Rotor Amps / 3./3. / / / / / / 7 Compressor Type croll croll croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3-2-2 /3-2-2 /3-2- /3-2-2 /3-2-2 /3-2- /3-2-2 /3-2-2 /3-2- /2-7- /2-7- 3/-7- Fan Motor--Amps Fan--DIA/CFM 2" - 0 2" - 0 2" - 0 2" " " " - 2" - 2" - 2" " " Blower Motor & Evap. Blower Motor--HP-RPM-PD /3--2 /3--2 /3--2 /3--2 /3--2 /3--2 / / / /--2 3/--2 3/--2 Blower Motor--Amps CFM Cooling & E..P w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx xx xx xx xx xx xx xx hipping Weight --LB Barometric Fresh Air Damper-Lbs Economizer-Lbs Form No. - upersedes - Page 2 of 2

3 Ventilation ystem Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date. BAROMETRIC FREH AIR DAMPER - BFAD TANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 2% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. MI-37 Barometric Fresh Air Damper Economizer MI-377 ECONOMIZER WECO eries OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outside ventilation air, up to 0% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. tandard Features: Fully modulating Honeywell Hi-Torque Actuator 7" intake hood with filter imple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available Form No. - upersedes - Page 3 of 2

4 Electrical pecifications J**AA eries (Field Installed Elec. Heat Only) MODEL JAA-A00,A0Z A0 A J2AA-A00, A0Z A0 A0 A J2AA-B00, B0Z Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: Rated Volts & Phase 2/- 2/- Form No. - upersedes - Page of 2 No. Field Power Circuits B0 2/-3 J2AA-C00, C0Z -3 C0 JAA-A00, A0Z A0 2/- A A or 2 JAA-B00, B0Z B0 B0 B JAA-C00, C0Z C0 C0 C2 C J3AA-A00, A0Z A0 A A J3AA-B00, B0Z B0 B0 B J3AA-C00, C0Z C0 C0 C2 C J2AA-A00, A0Z A A A J2AA-B00, B0Z B0 B B J2AA-C00, C0Z C0 C JAA-A00, A0Z A A A JAA-B00, B0Z B0 B B JAA-C00, C0Z C0 C JAA-A00, A0Z A A A JAA-B00, B0Z B0 B B JAA-C00, C0Z C0 C J72AA-A00, A0Z A A A J72AA-B00, B0Z B0 B B J72AA-C00, C0Z C0 C 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 or 2 or 2 or 2 or 2 or 2 or 2 or 2 2 or 2 or 2 or 3 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize Ground Wire Multiple Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes

5 Electrical pecifications J**LA eries (Field Installed Elec. Heat Only) MODEL JLA-A00,A0Z A0 A J2LA-A00, A0Z A0 A J2LA-B00, B0Z Rated Volts & Phase 2/- 2/- No. Field Power Circuits B0 2/-3 J2LA-C00, C0Z -3 C0 JLA-A00, A0Z A0 2/- A A or 2 JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C J3LA-A00, A0Z A A J3LA-B00, B0Z B0 B J3LA-C00, C0Z C0 C J2LA-A00, A0Z A A J2LA-B00, B0Z B0 B J2LA-C00, C0Z C0 C JLA-A00, A0Z A A JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C JLA-A00, A0Z A A JLA-B00, B0Z B0 B JLA-C00, C0Z C0 C J72LA-A00, A0Z A A J72LA-B00, B0Z B0 B J72LA-C00, C0Z C0 C 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 2/- 2/-3-3 or 2 or 2 or 2 or 2 or 2 or 2 Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize Ground Wire Dual Circuit Minimum Maximum Circuit External Fuse Field Power Ground Ampacity or Ckt. Breaker Wire ize Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes. 2 2 Form No. - upersedes - Page of 2

6 Indoor Blower Performance ( Hz) - CFM at Rated Voltage peed J J2 J J3 J2 J J J72 High Low ingle High Low High Low High Low High Low High Low High Low EP (Inch H) Above data is with " standard throwaway filter and " washable filter. For optional 2" pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. Factory Connected peed. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Nominal KW Kw At 20V () At V () At 0V (2) At V (2) -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh , , , ,7.0.0.,7. 2.,.0 7.2,7.2., ,.00 2., , ,03.0., , , , , ,3.0.0, , , , ,3.., , , () These electric heaters are available in 2/V units only. (2) These electric heaters are available in 0V units only. Form No. - upersedes - Page of 2

7 Heater Packages - Field Installed "A" eries Right-Hand Units Designed for adding Electric Heat to 0 KW Units Circuit Breaker tandard on 2/V Models Air Conditioner Models -A00 Models 2/- ETL U & Canada Listed Toggle Disconnect tandard on V Models -B00 Models 2/-3 -C00 Models -3 Heater Model # KW Heater Model # KW Heater Model # KW JAA EHWA02-B EHW02A-A0B EHWA02A-AB J2AA EHWA2A-A0B EHWA02-B EHW02A-A0B EHWA02A-AB EHWA2-B0B EHWH2B-C0 JAA EHWA03-B EHWA03-A0B EHWA03-AB EHWA03-AB EHWA03-B0B EHWA03-B0B EHWA37-BB EHWC03A-C0 EHWC03A-C0 EHWA03A-C2 EHWA03A-C 2 J3AA EHWA03-B EHWA03-A0B EHWA03-AB EHWA03-AB EHW3A-B0B EHWA03-B0B EHWA37-BB EHWC03A-C0 EHWC03A-C0 EHWA03A-C2 EHWA03A-C 2 J2AA JAA EHWTA- EHW-AB EHW-AB EHW-AB EHW-B0B EHW-BB EHWTA-B EHWTA-C0 EHWTA-C JAA EHWTA- EHW-AB EHW-AB EHW-AB EHWA-B0B EHW-BB EHWTA-B EHWTA-C0 EHWTA-C J72AA EHWTA- EHW-A EHW-A EHW-A EHW70A-B0B EHW-BB EHWTA-B EHWA-C0 EHWTA-C NOTE: Field installed Heater Packages are not approved for use with top supply opening models. These heater packages approved for use in dehumidification versions with hot gas reheat. Heater Packages - Field Installed "L" eries Left-Hand Units Air Conditioner Models -A00 Models 2/- -B00 Models 2/-3 -C00 Models -3 Heater Model # KW Heater Model # KW Heater Model # KW JLA EHWA02A-LB EHW02A-A0LB EHWA02-ALB J2LA EHWA02A-LB EHW02A-A0LB EHWA02-ALB EHWA2-B0LB JLA EHWA03-LB EHWA03-A0LB EHWA03-ALB EHWA03-ALB EHWA03-B0LB EHWA37-BLB EHWC03-C0L EHWA03-CL J3LA EHWA03-LB EHWA03-ALB EHWA03-ALB EHWA03-B0LB EHWA37-BLB EHWC03-C0L EHWA03-CL J2LA JLA EHWTA-L EHW-ALB EHW-ALB EHW-B0LB EHW-BLB EHWTA-C0L EHWTA-CL JLA EHWTA-L EHW-ALB EHW-ALB EHWA-B0LB EHW-BLB EHWTA-C0L EHWTA-CL J72LA EHWTA-L EHW-AL EHW-AL EHW70A-B0L EHW-BL EHWTA-C0L EHWTA-CL Form No. - upersedes - Page 7 of 2

8 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE JAA, J2AA, JAA, J3AA " " J2AA, JAA, JAA, J72AA " " NOTE: For side-by-side installation of two (2) JA models, there must be " between units. This can be reduced to " by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET JAA, J2AA 0" 0" JAA, J3AA /" 0" J2AA, JAA, JAA, J72AA /" 0" Refer to the Installation Manual for more detailed information. Dimensions of J-72AA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL JAA J2AA JAA J3AA J2AA JAA JAA J72AA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T W Built In Rain Hood Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for CRV and ECON models only D A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O upply Air Opening B. R. F G Filter Access Panel Ventilation Air Condenser Air Outlet tandard flush vent door for non- ERV/CRV Econ. models 3" 7.00 Low Voltage Electrical Entrance High Voltage Electrical Entrance Cond. Air Inlet J C K H Optional Electrical Entrances L M P Return Air Opening T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-37 Not used when WECO Economizers installed. Filter access is through the WECO hood. Form No. - upersedes - Page of 2

9 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE JLA, J2LA, JLA, J3LA " " J2LA, JLA, JLA, J70LA " " NOTE: For side-by-side installation of two (2) JL models, there must be " between units. This can be reduced to " by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET JLA, J2LA 0" 0" JLA, J3LA /" 0" J2LA, JLA, JLA, J70LA /" 0" Refer to the Installation Manual for more detailed information. Dimensions of J-72LA Basic Unit for Architectural & Installation Requirements (Nominal) MODEL JLA J2LA JLA J3LA J2LA JLA JLA J72LA WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T R E Heater O Pitch Access. Panel D W upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Built In Rain Hood 2.3 A I.2 Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) tandard flush vent door for non-erv/crv Econ. models Hood for CRV and ECON models only Return Air Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air. F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3737 Not used when WECO Economizers installed. Filter access is through the WECO hood. Form No. - upersedes - Page of 2

10 Cooling Application Data - Outdoor Temperature Model J J2 J J3 J2 J J J72 Return Air (DB/WB) 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 7/2 0/7 /72 Cooling Capacity 7 F 0 F F 0 F F 0 F F F F F 2 F Below F (.3C), unit requires a factory or field installed low ambient control. Return air temperature Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH ensible BTUH Form No. - upersedes - Page of 2

11 Air Conditioning Wall-Mount Model Nomenclature ERIE NOMINAL CAPACITY - ½ Ton 2-2 Ton - 2½ Ton 3-3 Ton 2-3½ Ton - Ton - Ton 72 - Ton J 3 A A A 00 X P X X X J A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide REVIION VOLT & PHAE A - 2/// B - 2///3 C - //3 KW VENTILATION OPTION (ee Table Below) FILTER OPTION P - 2-inch Pleated (MERV ) COLOR OPTION X - Beige (tandard) COIL OPTION X - tandard CONTROL MODULE (ee Chart Below) UPPLY AIR OUTLET X - Front (tandard) For 0KW and circuit breakers (2/ Volt) or toggle disconnects ( Volt) applications, insert 0Z in the KW field of the model number. ee Pages & for available Factory Installed KW options and Page 7 for Field Installed Heater Packages. Ventilation Options Models Description Factory Installed Code No. JAA, J2AA JLA, J2LA Field Installed Part No. Factory Installed Code No. JAA, J3AA JLA, J3LA Field Installed Part No. J2AA, JAA, JAA, J72AA J2LA, JLA, JLA, J72LA Factory Installed Field Installed Code No. Part No. Barometric Fresh Air Damper - tandard X BFAD-2 X BFAD-3 X BFAD- Economizer w/plug, Temp Only (7" Hood) Y WECOPT2-X Y WECOPT3-X Y WECOPT-X Economizer w/plug, Enthalpy (7" Hood) Z WECOPE2-X Z WECOPE3-X Z WECOPE-X Air Conditioning Control Modules All Models Except As Noted HPC LPC CCM LAC ALR K K Factory Installed Code Field Installed Part TD TD TD J Factory Only TD TD TD Field Installed Only CMC- K Except J & J72 TD TD TD Field Installed Only K2 J72 Only K22 J Only TD = tandard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. CCM. Compressor control module has adjustable -second to -minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to 0 F. LAC is fan-cycling control for outdoor fan motor on all models. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. K. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if K or K2 is used. K. tart capacitor & potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC- is used. Form No. - upersedes - Page of 2

12 NOTE Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. May, upersedes - Form No. - upersedes - Page 2 of 2

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan DCH Series Submittal Data Form 7½ - 12½ Ton Packaged Heat Pump Up to 11.5 EER & 3.4 COP Cooling Capacity: 90,000 140,000 BTU/h Heating Capacity: 90,000 142,000 BTU/h Job Name Purchaser Order No. Engineer

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard

More information

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210565 December 2010 Supersedes November 2010 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST Model EIFM-5C For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Installation Instructions

Installation Instructions 50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P

More information

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound 24VNA9 Infinityr 19VS Variable Air Conditioner with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 19VS air conditioner offers high -efficiency variable speed performance in a remarkably small

More information

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) Product Data the environmentally sound refrigerant Carrier s Air Conditioners with Puronr refrigerant provide

More information

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF DTH Series Submittal Data Form 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF Cooling Capacity: 35,000 60,000 BTU/h Heating Capacity: 32,800 55,500 BTU/h Purchaser Order No. Engineer Unit No. Model

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name:

Product Submittal. Project Information Project Name: Ulta 1307 Seneca SC. Customer Information Company Name: Engineering Information Company Name: Project Information Project Name: Ulta 1307 Seneca SC Product Submittal Project Number: 3000662696 Project Location: HARTWELL VILLAGE SENECA, SC 29678, US Project Altitude: 956 Customer Information Company

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013 Replacement Parts List No. 700017400 Revision G 12/2013 Daikin McQuay Incremental Comfort System PKEI, PKES, PKHS 007, 009, 012, 014 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

DCG Series. Submittal Data Form. 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 3-6 Ton Packaged Gas/ Electric Units 13 SEER / up to 11.3 EER / 80% AFUE 6-Ton with Two-Speed Blower Motor and Two-Stage Compressor Up to 15.5 IEER Cooling Capacity:

More information

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER HVH8 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUP WITH OBSERVER COUNICATING CONTROL SYSTE 2 THRU 5 TONS SPLIT SYSTE 208 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Variable

More information

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES: 16 SEER 2---Stage Split---tem Heat Pump With R---410A Refrigerant 2 To 5 Tons (024---060) Product Data NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features

More information

Parts List, Wiring Diagrams

Parts List, Wiring Diagrams Parts List, Wiring Diagrams PAH 210-300 SERIES 3 Phase PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST --------------2-5 PARTS DRAWINGS ------ 6-22 CHARGING CHARTS ---- 23-25 WIRING DIAGRAMS

More information

Precision Cooling. Precision Cooling Advantages

Precision Cooling. Precision Cooling Advantages Precision Cooling Today s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing

More information

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons Series Multi-Position, Internal TXV Multi-Speed ECM Based Air Handler ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions... Airflow Data...6 Heat Kit Data... Wiring

More information

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS Product Data SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 Model 38TDA Air Conditioners incorporate innovative 2-speed compressor technology to provide quiet, efficient

More information

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton :: Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton :: 7.0 17.5 kw Features and Benefits Built for critical applications Two-stages of cooling allows for

More information

CONDENSING UNITS UASL- JEC

CONDENSING UNITS UASL- JEC FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic

More information

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintage A. TYA, TAA No Vintage. Last Manufactured: 1993 Replacement Parts List No. 055203200 Revision G 08/2017 McQuay Climate Control Singer Incremental NE, NH, NR 07-15 Vintage A TYA, TAA 007-015 No Vintage Last Manufactured: 1993 To find your Daikin Applied

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M INSTALLATION INSTRUCTIONS PECCSUN672 Series Power Exhaust for York - 6 Ton Units Before Starting Installation Warning Severe injury can result from incorrect servicing. Only qualified HVAC service personnel

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

Contents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...

Contents. Cabinet Components  Exploded View... 1  Usage List U.S. Models... 2  Usage List Canadian Models... 3  Blank Page... Replacement Parts Manual WAG SERIES COMBINATION GAS / ELECTRICS Models: WAG30D WAG36D WAG40D General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual

More information

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners Models: ComPac AVPA 42-48-60 The following instructions describe how to install the Marvair External Bolt-On Field Installed

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004 Replacement s List No. 057111400 Revision A 08/2011 McQuay Commercial Unitary Rooftop Cooling Only or with Electric Heat LCA 180-240 Design 1 Last Manufactured: 2004 To find your Daikin Applied parts distributor,

More information

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions Controls Guide for XeteX Units Beyond meeting the typical specification and performance requirements, controlling the equipment is usually the most important success factor for HVAC projects. XeteX provides

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS EIFM CONTROL REPLACEMENT KIT 8620-239 For Use with 3-1/2 Through 6 Ton Wall Mount Air Conditioners and Heat Pumps with EIFM-5* Economizers or "E" Vent Option Bard Manufacturing

More information

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System 16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control System Efficiencies up to 16.5 SEER/13.0 EER Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

YORK HVAC PRODUCT GUIDE

YORK HVAC PRODUCT GUIDE YORK HVAC PRODUCT GUIDE PD 2/4/2014 v 1.3 Pricing shown is in U.S. Dollars Pricing subject to change without notice 1 Table of Contents Mated ERVs...2 OA Hood Economizer Systems...3 Hood and Duct Part

More information

Preliminary Supplement Instructions

Preliminary Supplement Instructions 48/50PG03---28, 48/50PM16---28 EnergyX Factory---Installed Energy Recovery Ventilator With COMFORTLink Controls and Puronr (R---410A) Refrigerant Preliminary Supplement Instructions This document is a

More information

Ceiling Concealed Split System C Series

Ceiling Concealed Split System C Series Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

Spring Test 5 due 4/26/2013

Spring Test 5 due 4/26/2013 Spring Test 5 due 4/26/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Where fixed multioutlet assemblies are employed, each feet or fraction thereof

More information

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

Self-Contained Air Conditioning Systems

Self-Contained Air Conditioning Systems Self-Contained Air Conditioning Systems 20 to 130 tons Proven Applications Testimonials Daikin is an industry leading manufacturer of self-contained air conditioning products. Ideal for jobs where energy

More information

IN STAL LA TION IN STRUC TION

IN STAL LA TION IN STRUC TION FORM# 654B-0511 (654B-0808) I - SHIP PING AND PACK ING LIST Check for correct number of parts. See list below. Package 1 of 1 contains: 1 - Economizer Assembly (Discharge Air Sensor Included) 1 - Barometric

More information

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13.0 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and provides up

More information

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 18 SEER /12.5 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 25VNA8 Infinityr 18VS Variable Heat Pump with Puronr Refrigerant 2 --- 5 Ton Product Data The Infinity 18VS heat pump offers high -efficiency variable speed performance in a remarkably small cabinet and

More information

Smartstart Control Module

Smartstart Control Module Smartstart TECHNOLOGY What is Smartstart? The patented Smartstart control module is an integrated, seamless solution that incorporates operator control, superior motor protection, and automation system

More information

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil

More information

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN ECON-ZIP-BASE ZIP Economizer Base Unit 24 VAC ± 20%, 50/60 Hz; Class 2 power source 4 VA Base Control (ECON-ZIP-BASE) 5.5 VA Base Control with Energy Module (ECON-ZIP-BASE + ECON-ZIP-EM) Power Consumption

More information

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series 16.0 Air Air Conditioners Rheem Prestige Series Two- Air Conditioners equipped with the Comfort Control 2 System Efficiencies up to 18 /14 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Cooling Capacities

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller MAKING MODERN LIVING POSSIBLE CI-tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Technical brochure Contents Page Soft start motor controller, MCI 3, MCI

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data SS-PRC014-EN Split System Cooling Product & Performance Data 2TTA0030-072A 2½ 6 Tons PUB. NO. 22-1740-01-0702 (EN) General Features Split System Cooling Units... The Evolution Continues 2TTA0 split systems

More information

ECON-ZIP-BASE. ZIP Economizer Base Module

ECON-ZIP-BASE. ZIP Economizer Base Module ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060

TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS MODELS: HL8B024 THRU 060 TECHNICAL GUIDE ACCLIMATE TM SERIES SPLIT-SYSTEM HEAT PUMPS 18 SEER R-410A 1 PHASE 2 THRU 5 NOMINAL TONS S: HL8B024 THRU 060 Due to continuous product improvement, specifications are subject to change

More information

Product Data. 24ANB1 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

Product Data. 24ANB1 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons Infinityt 21 2---Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons Carrier s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

IPS INTELLIGENT PUMP STARTER

IPS INTELLIGENT PUMP STARTER IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60

More information

Product Data. Reliability

Product Data. Reliability Infinityt19 2 --- Stage Heat Pump with Puronr Refrigerant 3to5NominalTons Product Data Carrier s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment.

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

Parts List, Charging Chart, Wiring Diagrams

Parts List, Charging Chart, Wiring Diagrams Parts List, Charging Chart, Wiring Diagrams PHH150, PHH180 3 Phase PACKAGE HEAT PUMP UNITS TABLE OF CONTENTS PARTS LIST------------ 2-5 PARTS DRAWING - - - - - - -6-16 CHARGING CHARTS - - - - - - - 17

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound

Product Data. S Up to 19 SEER /13 EER / 11 HSPF S Microtube Technologyt refrigeration system Sound 288BNV EVOLUTION R V VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT 2, 3, 4 AND 5-TON Product Data The Evolutionr V heat pump offers high -efficiency variable speed performance in a remarkably small

More information

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases

PROLINE ExtERNal ComPONENts. PROLINE tops and Bases Spec-00428 E763.422.2211 763.422.2600 PROLINE ExtERNal ComPONENts PROLINE Tops and Bases PROLINE ExtERNal ComPONENts PROLINE tops and Bases Solid tops Solid Tops are used to close the top opening on an

More information

4-step Chiller and Heat Pump Controller

4-step Chiller and Heat Pump Controller 4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

J&M Fluidics, Inc. Company Product Overview

J&M Fluidics, Inc. Company Product Overview It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania

More information

AIR COOLED MODULAR RECTIFIER

AIR COOLED MODULAR RECTIFIER CONTROLLED POWER COMPANY SPECIFICATIONS AIR COOLED MODULAR RECTIFIER Spc1800a1 5JAN1999 SPECIFICATION S-1800-A MODULAR (REMOVABLE AND NON-REMOVABLE MODULES) AIR COOLED RECTIFIER Standard output power range:

More information

Company, Simplex Onsite, providing nationwide load bank rentals.

Company, Simplex Onsite, providing nationwide load bank rentals. Trident 2500 1500KW - 2500KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control Very high capacity, 1500-2500kw Dual voltage: 208-240/416-480vAC Digital

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions Before Starting Installation Warning Shut power to unit prior to any work being done. Personal injury or death could result. Only qualified HVAC service personnel should install, troubleshoot, repair or

More information