1 DCP-A Panel Network DALI Control Panel for DALI Ballast, DALI Relays and DALI Dimmers The DCP-A electronic network control panel with Clipsal DCDALCIP250-2 serial interfaces supports applications requiring multiple DALI communication buses. The wall mount enclosure is available with up to 4 DALI lines interfaces supporting a maximum of 256 DALI Ballasts, DALI Relays or DALI 120V Dimmers. Additional space is provided in the panel for mounting an optional Clipsal DCB Ethernet-to-Serial RTC controllers or LAN to RS-232 multi-port serial hub. Control and monitor multiple DALI communication buses Equipped for Digital two-way communications with RS-232 serial devices. LAN communication requires optional interface Easily adds additional DALI buses to existing systems Field-expandable (for up to 4 DALI buses) Convenient 120 V electrical outlet for powering optional LAN interface Optional 120 VAC outlet Optional additional 24V DC Transformer for driving external 24V occupancy sensors Approved for Class 1 and Class 2 DALI control wiring installations 5-port 10/100Mb Ethernet Switch UL508-A NEMA-1 wall mount enclosure with hinged door Safety: ETL UL916, CSA C22.2 No year warranty Order Description Panel Voltage Panel Watts * DALI bus Maximum number of DALI Number VAC W support addressable devices (ballast) SLS-DCP-A-2 DCP-A-w/ 1 DALI Lines SLS-DCP-A-4 DCP-A-w/ 4 DALI Lines Each loop can be loaded up to a maximum of 220 ma nominal at 15VDC. Accessories Order Description Wattage Input Voltage Output Voltage Number BM-2600 DALI Ethernet/Serial Controller w/rtc, 2 RS-232 ports, 1 RJ45, 16 inputs <1W 24V DC - NP-5410 DALI-MX LAN 4xRS232 Moxa LAN interface with 4 RS-232 ports <1W 24V DC - DR30-12 MEANWELL DR30 Transformer. 120VAC input, output 30 W 120V AC 12V DC DR60-24 MEANWELL DR60 Transformer. 120VAC input, output 60 W 120V AC 24V DC

2 Mounting and Environment The electronic network control panel is designed for wall mounting. Panel should be installed in an electrical or mechanical equipment room. The unit should be mounted a minimum of 6 inches away from any other enclosure. Panel should not be exposed to the weather or used in an environment where humidity is condensing on it. Mount enclosure with door hinge on the left side. Verify that a minimum door swing clearance of 28 inches is provided. Panel Wiring Class 1 5-wire in conduit DALI wires 600V 120/277 VAC DALI Bus Connections The enclosure requires connection of 120VAC for the duplex receptacles. Receptacles are intended for powering the Busmaster interfaces and optional communication interface. Receptacles are not intended to power other equipment. Refer to table for power loading requirement. Class 2 The cavity in the middle of the enclosure is designed to house an optional interface to convert LAN Ethernet communications to serial RS-232. DALI bus wiring can be installed as either a Class 1 or Class 2 installation (reference drawings). Class 1 installation: Wiring for DALI Bus and AC load wiring in same conduit. Class 2 installation with the DALI bus wiring separated from AC load wiring. The DALI CONTROL PANEL is a complete DALI head-end panel enclosing CLIPSAL DCBM intelligent real-time-clock schedulers, DALI (220 ma) power supplies plus DALI Serial interfaces, to support up to 4 DALI loops. Via the building Ethernet, the panels are connected to both individual users & administrators both building level overrides, automated sweeps and individual user level control of their assigned fixtures. D A L I C O N T R O L P A N E L 120/277 VAC DALI Bus

3 24V DC Device Layout and Conduit Access 120V AC Into panel DALI Out to Loop 120V 15 Amp Circuit Breaker 120V Distribution 24V Transformer Clipsal DCBM DALI Controller 120V Socket Clipsal DCDAL- CIP V Distribution 5-Port Ethernet Switch Ethernet DALI to Relay Panel Scale 4:1 Low Voltage Switches

4 DCBM DALI Control Panel DCP-A DCBM DALI CONTROL PANEL A WIRING DETAILS 120 VAC CIRCUIT BREAKER DALI CONTROL PANEL A 120VAC DISTRIBUTION 24V DC CLASS 1 CLIPSAL DCDAL- CIP250-2 DALI POWER SUP- PLIES AND SE- RIAL I/F 24VDC DISTRIBUTION ETHERNET SWITCH CLASS 2 ETHERNET DALI DALI LOOPS 1-4

5 Installation Instructions: When installing enclosure and making electrical connections it is important to follow all codes applicable to lighting control equipment. 1) See enclosure drawing for additional support information. 2) Locate area on wall to mount enclosure. 1. Panel dimension is (DCP-A) 24"x20"x6" with hinge door on left side. 2. Panel dimension is (DCP-B) 36"x24"x6" with hinge door on left side. 3) It is recommended that a minimum space of 8 inches is available between enclosure and other object (wall or other enclosure). 4) Position the enclosure with the door hinge on the left side. Fasten enclosure to wall using mounting holes located at each corner of the back enclosure. 5) Route all power (120V classified as Class One wiring) to the left side top of the enclosure that contains the circuit breaker. a. Feed 120VAC into the Class One wiring compartment. Connect 120VAC power to circuit breaker within enclosure according to National and Local Electrical Codes. i) Torque 120V Hot and Neutral Terminals to 21 lb-in ii) Torque Ground Terminal to 14 lb-in b. Identify DALI loops and connect them to the terminal blocks provided on each BusMaster. (Caution - DO NOT CONNECT 120VAC to the DALI terminal blocks) 6) Route the computer interface cable into the right side of the enclosure (classified as Class 2 wiring). a. Verify the proper computer interface is installed into the compartment on the right side of the enclosure. b. Verify the serial communication cables between the network interface and the BusMaster(s) are in place. 7) Connect network interface cable to the communications adaptor located in the compartment. 8) Check all wiring to make sure there are no loose connections. Make sure the enclosure is properly grounded (per code requirements). 9) Close enclosure door after completing the installation and wiring. Operation checklist: 1. Verify that 120VAC power is available to the outlets located in the enclosure. 2. Check that the green power LEDs on all AC/DC Transformers are illuminated. 3. Check that the green power LEDs on each BusMaster is illuminated. 4. Make sure that the power indicator of the Ethernet switch is illuminated. 5. Make sure that the power indicator of the computer interface (Moxa or BM2600) is illuminated. 6. To check enclosure functionally, refer to system operating and commissioning guides.

6 Dimensions Dimensions In inches

Instruction Manual HPH-8

Instruction Manual HPH-8 Specifications HPH-8 Trigger cable 120-volt, Nema 1-15 Main Power 50-amps @ 240-volt AC Power receptacles (4) Nema 5-15 or 6-15 Maximum HID wattage 8000 watts (on 240-volt) 4800 watts (on 120-volt) Maximum

More information

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 (pg. 6) Flat; Corner (pg. 5) Wire Size PERFORMANCE

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 (pg. 6) Flat; Corner (pg. 5) Wire Size PERFORMANCE CLOSET RATED is a high performance LED fixture suitable for use in closets, under cabinets, and in shelving. has a built-in motion sensor that activates the light without the need for a wall switch or

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

QuantumR Light Management Hub (QP2)

QuantumR Light Management Hub (QP2) Quantum 369375f 1 11.05.15 QuantumR Hub (QP2) The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, and QS devices

More information

Single Phase Systems-North American PC125/PC420 Series

Single Phase Systems-North American PC125/PC420 Series Single Phase Systems-North American PC125/PC420 Series Enclosure Power Distribution Units (epdu ) PC125-C Front RACK MOUNTED 19 x 3.4 (2U) x 8.5. Approximate shipping weight: 19 lbs. (12) NEMA OUTLETS

More information

CS XL XM. EcoSystem Bus Supply

CS XL XM. EcoSystem Bus Supply EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast

More information

QuantumR Light Management Hub

QuantumR Light Management Hub Quantum 369375e 1 04.02.2015 QuantumR Light Management Hub The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, GRAFIK

More information

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 Flat; Corner Wire Size PERFORMANCE. Field of View CRI Lumen Maintenance Binning Tolerance Warranty + +

ACCESSORIES. Driver Mounting Clips. OWA-60U-24 Flat; Corner Wire Size PERFORMANCE. Field of View CRI Lumen Maintenance Binning Tolerance Warranty + + NITELIGHT is a high performance LED fixture suitable for use in closets, under cabinets, and in shelving. NITELIGHT has a built-in motion sensor that activates the light without the need for a wall switch

More information

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE 2 Part Number: WIR-3110 WARNING! SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES

More information

CAUTION READ CAREFULLY

CAUTION READ CAREFULLY Docking Drawer Install Manual for DD 21 + 24 Slim Applicable Models: 0290-00030, 0290-00030W, 0290 00031, 0290 00031W 0230-00004. r5 10/21/2015 CAUTION READ CAREFULLY Failure to follow these instructions

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

TALON Network Manager- 2 & 6 Express

TALON Network Manager- 2 & 6 Express Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator

More information

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN. The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant

More information

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90 Cloud capable and communicating valve actuator for adjusting flow in commercial HVAC applications. Non-Failsafe Power Supply AC/DC 24 V Used for CCV and LGCCV assemblies Ethernet 10/100 Mbit/s, TCP/IP,

More information

Premium Online Series

Premium Online Series Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to

More information

TILE Interior TILE Tunable White LINE

TILE Interior TILE Tunable White LINE 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE CUL LISTED POWER & CONTROL (58V) SPECIFICATIONS PROJECT REFERENCE TYPE SPECIFIED BY QUANTITY DATE NOTE For Luminous Surfaces SYSTEM OVERVIEW Control

More information

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided Industrial 2-port Gigabit High Power PoE Injector, 24V~50V Input Support Features Supports 2x10/100/1000Base-T(X) for power and data Output Fully compliant with IEEE802.3at/802.3af standard Auto protection

More information

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac

More information

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB FS 120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans and Solid State Fan Controllers Model: NB181608-10FS Applications and Features Features: Molded Fiberglass Reinforced Polyester

More information

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

Scout Select System White

Scout Select System White JOb Name : Fixture Type : one Engine - Three Intensities 2.5 5.0 10.0 2.5 Watts / Foot 180 Lumens / Watt 450 Lumens / Foot 5.0 Watts / Foot 150 Lumens / Watt 750 Lumens / Foot 10.0 Watts / Foot 120 Lumens

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers

More information

Model DMX24DIM Installation and Operations Manual

Model DMX24DIM Installation and Operations Manual DOUG FLEENOR DESIGN, Inc. Model DMX24DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision November

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B Installing the ILC LightSync 4.3 or 7 Touch Screen Station Rev. B Overview: The ILC LightSync Touch Screen station (LS-TSS) is available with 4.3 and 7.0 screens. The assembly includes a galvanized NEMA-1

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL

More information

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90 Cloud capable and communicating failsafe valve actuator for adjusting flow in commercial HVAC applications. Failsafe Power Supply AC/DC 24 V Used for CCV and LGCCV assemblies. Ethernet 10/100 Mbit/s, TCP/IP,

More information

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi ) Cloud capable and communicating failsafe damper actuator for adjusting dampers in commercial HVAC applications. Failsafe Air Damper Size Up to approx. 45 sq. ft. Nominal Torque 180 in lb [20 NM] Power

More information

LANDSCAPE TRANSFORMERS

LANDSCAPE TRANSFORMERS LANDSCAPE TRANSFORMERS Precision Power. Perfect Light. Remote Transformers Linear Fluorescents Sign Ballasts Electronic HID LED Drivers Landscape Transformers Hatch Landscape Transformers have been designed

More information

PANELITE ENCLOSURE LIGHTS OVERVIEW

PANELITE ENCLOSURE LIGHTS OVERVIEW SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for

More information

High Power over Ethernet Midspans PD Port Model PD Port Model

High Power over Ethernet Midspans PD Port Model PD Port Model Data and Power on a Single Line High Power over Ethernet Midspans PD-8006-6 Port Model PD-8012-12 Port Model User Guide Notice The information contained herein is believed to be accurate and reliable at

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding. Version: 2011-01-13 BMCS CCX Cabinet Description & Function: The BMCS_CCX Cabinet is a ready to install wall housing for one or more BMCS systems (see figures 1 to 3). The BMCS_CCX Cabinet is designed

More information

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Housing MODEL NUMBER: STRIKER Highlights 7 NEMA 5-15R outlets one designed for a bulky transformer 1080-joule surge protection

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure 550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION: USE COPPER CONDUCTOR ONLY CAUTION: RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker before installing

More information

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1 Version 3.1: September 22, 2017. Please note that this Revision 3.1 may be subject to subsequent revisions.

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

10/100/1000TxBase-T(X) P.D. input port and two 10/100/1000TxBase-T(X) P.S.E. output ports, the device not only pass on

10/100/1000TxBase-T(X) P.D. input port and two 10/100/1000TxBase-T(X) P.S.E. output ports, the device not only pass on Industrial 2-port Gigabit High Power PoE++ Extender Features Support 1 port PoE P.D. input to 2 port POE P.S.E output with 10/100/1000 Base-T(X) for power and data extender Support P.S.E. based on IEEE

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

Three Phase Systems-International PC302-I/MTD

Three Phase Systems-International PC302-I/MTD Three Phase Systems-International PC302-I/MTD Enclosure Power Distribution Units (epdu ) sales@pulizzi.com 800-870-2248 Fax: 605-334-4999 Front RACK MOUNTED 19 x 3.4 (2U) x 8.5 with recess mounting Approximate

More information

C-Bus Interface Devices for wider control of a home or building.

C-Bus Interface Devices for wider control of a home or building. 15/11/2018 C-Bus Interface Devices - Clipsal by Schneider Electric C-Bus Interface Devices for wider control of a home or building. C-Bus interface devices play a key role in allowing C-Bus to control

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input Features Supports 2x10/100/1000Base-T(X) for power and data Fully compliant with IEEE802.3at/802.3af standard Auto protection for Over

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

INJ-24A Series Quick Installation Guide

INJ-24A Series Quick Installation Guide INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage Technical Instruction Document Modbus Header Temperature Kits: 24444-1 Standard Voltage 24444-3 Low Voltage Disclaimer The information contained in this manual is subject to change without notice from

More information

Switched Relay Controller - Relay Panel with Breakers

Switched Relay Controller - Relay Panel with Breakers Installation Instructions Model # SC-RPB INS # Contents Contents Description Page Safety....................................................................... 3 Please Read This First... 3 Introduction...

More information

ecna-5 D-Cinema Automation System

ecna-5 D-Cinema Automation System F E A T U R E S Web browser based tools including configuration backup/restore and firmware update capabilities Embedded SNTP client for synchronizing the clock with an NTP (Network Time Protocol) server

More information

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR8ULTRA Highlights 8 NEMA 5-15R outlets in exclusive isolated filter banks

More information

Transceiver Hub with Integral Camera Power

Transceiver Hub with Integral Camera Power Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:

More information

Installation and Hardware Guide

Installation and Hardware Guide Helios W.E.S. 1000 & 2000 (Wireless Emergency Stop) Installation and Hardware Guide E5, Version 1.3 Helios Global Tech Ltd. Contact Information Helios Global Technologies 1920 Windsor Rd Kelowna BC V1Y

More information

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter banks

More information

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time. Datasheet Lighting Expansion Modules Overview Applications On/Off lighting 1-10 V dimming lighting The Expansion Modules are microprocessor-based interfaces that extend the number of inputs and outputs

More information

onlinecomponents.com

onlinecomponents.com R General-Purpose Fiber-optic Sensor Compact Limit Switch Style with Universal Supply H FET output allows for solid state switching of AC or DC H Universal AC/DC power supply H Choose cable or connector

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

XBR V4 INSTALLATION AND USER GUIDE

XBR V4 INSTALLATION AND USER GUIDE XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson

More information

Model DMX8DIM Installation and Operations Manual

Model DMX8DIM Installation and Operations Manual Model DMX8DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision June, 2018 Product description The

More information

PROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS:

PROJECT: SPECIFIER: TYPE: QTY: OUTPUT LEVEL: COLOR: LENGTH X WIDTH: MOUNTING: DIMMING/CONTROLS: PROJECT: SPECIFIER: TYPE: QTY: Available in 5 output levels of Static White at 24 Volts RGB and RGBW available at 24 Volts Tunable White and Double Sided available Great for creating Luminous Ceilings

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1200LCD Highlights Supports a half-load (350W) up to 14.3 min. during power outage

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems.

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

MOXA EtherDevice Switch & PoE Splitter

MOXA EtherDevice Switch & PoE Splitter MOXA EtherDevice Switch & PoE Splitter EDS-P308 & SPL-24 Hardware Installation Guide First Edition, July 2006 Moxa Networking Co., Ltd. Tel: +886-2-2910-1230 Fax: +886-2-2910-1231 www.moxa.com support@moxanet.com

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

System Installation guide

System Installation guide System Installation guide Ligo System installation guide V3 newestpage 1 of 14 Contents 1 INTRODUCTION... 3 2 SYSTEM TOPOLOGY... 3 3 CONTROL ELEMENTS... 4 3.1 LIGO CONTROLLERS... 4 3.2 IP DOMAIN... 5 3.3

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade

More information

PT-7728/7828 Quick Installation Guide

PT-7728/7828 Quick Installation Guide PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information