AO-1202 DALI to RS485 Converter. User Manual
|
|
- Rosaline Bryan
- 5 years ago
- Views:
Transcription
1 AO-1202 DALI to RS485 Converter User Manual 2012/7/19
2 Index 1. Introduction Wiring...2 Using as a DALI Power Supply only...2 Single DALI Loop...3 Multiple DALI Loops Quick Set...3 RS485 ID programming and acknowledge (command code D2 and A1)...4 transfer DALI command from Host PC to DALI network (command code D2)...5 transfer DALI information from DALI network to Host PC...5 Query command from Host PC to (command code D3) Module Specification...7 Page 1 of 2
3 1. Introduction DALI (Digital Addressable Lighting Interface) is the lasted international standard of lighting control interface. DALI to RS485 Converter is designed to transfer control command between RS485 bus and DALI bus. DALI to RS485 Converter has built in DALI Power Supply for DALI Bus. This unique function is suitable for small area DLAI lighting system. 2. Wiring supports both Point to Point and Point to Peer RS485 half duplex network. The wiring method is below. Using as a DALI Power Supply only DALI Lighting Device DALI Lighting Device DALI DALI Switch DALI Switch Page 2 of 3
4 Single DALI Loop HOST PC TCPIP USB RS232 RS485 Converter RS485 RS485 ID=1 DALI Loop #1 Multiple DALI Loops HOST PC TCPIP USB RS232 RS485 Converter RS485 RS485 ID=1 DALI Loop #1 RS485 ID=1 DALI Loop #2 Max 255 RS485 ID=255 DALI Loop #255 Note: The number of is depended on the driving force of RS485 converter. support the maximum number is 3. Quick Set There has a set of communication protocol for to working under Multiple DALI Loops and Remote Control environment. This protocol is showing below: Header Check1 Direction Pay Load #1 Command Pay Load #2 Check sum End 2bytes 2bytes Description: (All data is HEX mode.) Header F1: The fowling data is for DALI control. F2: The fowling data is for setting. Page 3 of 4
5 Check1 Direction Pay Load #1 Command Pay Load #2 Check sum End code Check code #1 = 07h 50: The fowling data is from Host PC to. 54: The fowling data is from to Host PC. Please reference to each command s detail description below. Please reference to each command s detail description below. Please reference to each command s detail description below. Check sum from Header to End code. Low byte only. End code = 55h RS485 ID programming and acknowledge (command code D2 and A1) Notice: Only one is connected to the RS485 network when user is performing RS485 ID Programming. The wiring method of RS485 ID Programming is showing below: HOST PC TCPIP USB RS232 RS485 Converter RS485 RS485 ID=1 The RS485 ID programming command is : F D2 L_ID 00 ADD 55 L_ID: ID for. D2h: Command for Rs485 ID setting. 50h: The fowling data is from Host PC to. F2h: The fowling data is for setting. When the programming procedure is done, the will respond acknowledge as below: Page 4 of 5
6 F L_ID xx A1 xx 00 ADD 55 Reversed, don t care. A1h: Command for responds Rs485 ID setting. L_ID: ID report form. 54h: The fowling data is from to Host PC. F2h: The fowling data is for setting. transfer DALI command from Host PC to DALI network (command code D2) F L_ID DD D2 CC 00 ADD 55 DD=DALI command byte, CC=DALI Data byte D2h: Command code for transfer DALI command to DALI bus. L_ID: ID for. 50h: The fowling data is from Host PC to. F1h: The fowling data is for DALI control. transfer DALI information from DALI network to Host PC. F L_ID DD A2 CC 00 ADD 55 DD=DALI command byte, CC=DALI Data byte A2h: Command code for transfer DALI command to Host PC L_ID: ID form. 50h: The fowling data is from Host PC to. F1h: The fowling data is for DALI control. 1. The third byte of data stream is used to identify the destination of the data. The 50h is from Host PC to and the 54h is from to Host PC. 2. The Host PC is able to recognize any changes on each DALI loop individual light change through the data L_ID DD CC byte on the data stream. Page 5 of 6
7 Query command from Host PC to (command code D3) Host PC is able to query any by using instruction D3h. F L_ID 00 D ADD 55 D3h: Query command for. L_ID: ID for query. 50h: The fowling data is from Host PC to. F2h: The fowling data is for setting. wills response a message as below: F L_ID 00 D ADD 55 D3h: Query command for. L_ID: ID for respond. 54h: The fowling data is from to Host PC. F2h: The fowling data is for setting. Page 6 of 7
8 4. Module Specification AC IN: 90~240V AC / 6W (max) Build in DALI Power: 16~25V/128mA RS485 Data Rate: 38400bps, 8, n, 1 DALI Bus Data Rate: 1200bps Size: 80mmX64mmX29.1mm Operation Tempura: 0~85 AO D A LI t o R S 485 B r i dger AC IN: 90~250V 50/60Hz D ATA I N : R S 485, 38400bps, 8, n, 1 O ut put : D A LI D C 16~25V / 250m A M ax DALI BUS E_GND AC IN RS485_B RS485_A RS485_GND Page 7 of 8
This document hosted by: 10. OPTIONS
This document hosted by: www.oldwillknottscales.com 10. OPTIONS The following options are available for the FG series: OP-23 (FG-23) RS-232C serial interface OP-24 (FG-24) RS-232C serial interface and
More informationCommunications guide. Line Distance Protection System * F1* GE Digital Energy. Title page
Title page GE Digital Energy D90 Plus Line Distance Protection System Communications guide D90 Plus firmware revision:.9x GE publication code: 60-9070-F (GEK-3469) GE Digital Energy 650 Markland Street
More informationThe benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationProduct Family: GS Drives Number: AN-GS-006
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationThe RS-485 user manual for B800 series communication
The user manual of B800 Series Rs-485 The RS-485 user manual for B800 series RS-232 inbuilt inside the main board of B800 series frequency inverter, we can effect RS-485 through fitting board externally.
More informationShenZhen Top Create Electronic Co.,Ltd. Website: Tel: CJ - CAM User Manual.
ShenZhen Top Create Electronic Co.,Ltd Website: www.szccge.cn.alibaba.com Tel: +86-755-25937185-85 CJ - CAM User Manual OV528 Protocol OV528 PROTOCOL Serial Interface Single-byte Timing Diagram RS232 single-byte
More informationCab Bus Communications Protocol
Page 1 Overview of Controller Bus The controller bus connects up to 63 Hand-Held Cab Controllers to the Command Station. Data on the bus runs at 9600 bps with 8 data bits, no parity, 2 stop bits and meets
More informationHello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol.
Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with ModBus RTU Communication Protocol. 1 Who Is This Guide For? The purpose of this guide is to show the correct procedure
More informationELECTRONIC METER SX1-A31E MODBUS RTU Protocol Specifications MDD-T0025A
ELECTRONIC METER SX1-A31E MODBUS RTU Protocol Specifications SPEC. NO. : MDD-T0025A MITSUBISHI ELECTRIC AUTOMATION (THAILAND) CO., LTD CONTENTS 1. Functions 2 2. Checking before usage... 2 3. System Configurations.
More informationC1098 JPEG Module User Manual
C1098 JPEG Module User Manual General Description C1098 is VGA camera module performs as a JPEG compressed still camera that can be attached to a wireless or PDA host. Users can send out a snapshot command
More informationN700E Inverter RS485 Interface Instruction Manual
Technical Support Document for Inverter Doc. No. Model TSD-N700E-COM-001E(00) All N700E model Rev. Date June, 2009 N700E Inverter RS485 Interface Instruction Manual Contents 1. RS485 function...1 1.1 function...1
More informationTOSVERT VF-S9 Communications Function Instruction Manual
TOSVERT VF-S9 Communications Function Instruction Manual Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using the communications
More informationTOSVERT VF-S15 Series RS485 Communication Function Instruction Manual
TOSVERT VF-S15 Series RS485 Communication Function Instruction Manual NOTICE 1. Read this manual before installing or operating. Keep this instruction manual on hand of the end user, and make use of this
More informationTongta Inverter TDS-F8
Tongta Inverter TDS-F8 MODBUS Communication Application Manual Please ensure the user gets this manual, for the optimal use of this device. 1. Introduction: TEK-DRIVE / TDS-F8 INVERTER MODBUS Communication
More informationSAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:
Thank you for purchasing Marathon Drive (MD100P) RS485 Option Card! SAFETY PRECAUTIONS Always follow safety precautions to prevent accidents and potential hazards from occurring. In this manual, safety
More informationMELSEC iq-f FX5 User's Manual (SLMP)
MELSEC iq-f FX5 User's Manual (SLMP) SAFETY PRECAUTIONS (Read these precautions before use.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully
More informationPOSITILT CAN SAE J1939 Output Specification
CAN SAE J1939 Output Specification Description Inclination sensor according to standard SAE J1939. Configuration of operating parameters by proprietary-a- Message (peer-to-peer connection). Process data
More informationIntroduction & Specifications of Hi-Speed USB to Serial Adapters
Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,
More informationHello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with LD Standard Communication Protocol.
Hello Angles... A First Use Guide to the SOLAR Product Series: RS485 Interface with LD Standard Communication Protocol. 1 Who Is This Guide For? The purpose of this guide is to show the correct procedure
More informationUSB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply
USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual The USB to industrial 16-Port RS-422/485 Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your
More informationIT6800 series Frame Format
IT6800 series Frame Format Programmable DC Power Supply Model IT6821/IT6822/IT6823/ IT6831/IT6832/IT6833/IT6834 Copyright 2004 All Rights Reserved Ver2.0 /Sep 2005/ IT6800-603 Directory About your safety...3
More informationWIEG-EXT Wiegand to RS485 extender module.
WIEG-EXT Wiegand to RS485 extender module. Designed for embedding into products manufactured by third-parties, this Wiegand to RS485 extender is designed to transfer wiegand data from Access Control Card
More informationLP-AW4001/LP-AW3001/LP-AX3001
LCD Projector LP-AW4001/LP-AW3001/LP-AX3001 User's Manual (detailed) Operating Guide Technical Supported signals for COMPUTER IN Resolution (H x V) Signal mode H. frequency V. frequency Rating (khz) (Hz)
More informationADDENDUM : APPA RS-232 PROTOCOL FOR DMM 301, 303, 305 USING WITH APPA RS-232 CABLE SOFTWARE LICENSE AGREEMENT FOR APPA WinDMM / 98 / NT
ADDENDUM : APPA RS-232 PROTOCOL FOR DMM 301, 303, 305 USING WITH APPA RS-232 CABLE SOFTWARE LICENSE AGREEMENT FOR APPA WinDMM300 95 / 98 / NT IMPOTANT : Please read carefully before using the Software
More informationCitrix IMA Service Error Codes
Citrix IMA Service Error Codes This article contains Citrix IMA Service error codes that can appear in the Event Viewer. Page 1 IMA Error Codes Hex Value Signed Value Unsigned Value Mnemonic 80000001h
More informationBULLETIN 1203-GD2, -GK2 & 1336-GM2 DF1 MESSAGING (FULL DUPLEX / POINT-TO-POINT)
BULLETIN 1203-GD2, -GK2 & 1336-GM2 DF1 MESSAGING (FULL DUPLEX / POINT-TO-POINT) APPLICATION NOTE OCTOBER 20, 1999 PURPOSE The purpose of this document is to provide information on using the DF1 Full Duplex/Point-to-Point
More informationEC-333 Microprocessor and Interfacing Techniques
EC-333 Microprocessor and Interfacing Techniques Lecture 3 The Microprocessor and its Architecture Dr Hashim Ali Fall - 2018 Department of Computer Science and Engineering HITEC University Taxila Slides
More informationSpecification. for. Serial Interface DN-C635
Date 2003-01-28 1 page of 39 Specification for Serial Interface DN-C635 Denon, Ltd. Date 2003-01-28 2 page of 39 Histories Rev. Date Name Description 1.0 Jan.,28, 03 J.Watanabe Date 2003-01-28 3 page of
More informationQEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0.
QEL - DEDESCO 5935 Ottawa Street Richmond, Ontario, Canada, K0A 2Z0. QTS-8000 RS-485 Data Communication Protocols 82050-005-000 Name Signature Date Prepared: Gang Li 00-05-15 Reviewed: Checked: Approved:
More information19.Configure HMI as a MODBUS Server
19-1 19.Configure HMI as a MODBUS Server This chapter explains how to configure HMI as a MODBUS Server. 19.1. Overview... 19-2 19.2. Steps to Create a MODBUS Server... 19-2 19.3. Steps to Access a MODBUS
More informationDigidim RS232 AV Interface
Digidim RS232 AV Interface to 910 / 920 Router Power/Status Digidim Router Dali 1 Dali 2 Link/Activity 910 (85 to 264)VAC DALI Dali 11 Dali 2 L N E SC DA- DA+ DA- DA+ User Guide Helvar Ltd Contents 1.
More informationMELSEC iq-f FX5 User's Manual (MELSEC Communication Protocol)
MELSEC iq-f FX5 User's Manual (MELSEC Communication Protocol) SAFETY PRECAUTIONS (Read these precautions before use.) Before using this product, please read this manual and the relevant manuals introduced
More informationGateway Ascii Command Protocol
Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4
More informationElotech Standard Protocol. for Single R8200 SC
Elotech Standard Protocol interface description / network protocol for Single R8200 SC ELOTECH Industrieelektronik GmbH Verbindungsstraße 27 D - 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255
More informationVS-LC101/ VS-LC102 RS-232 command set
VS-LC101/ VS-LC102 RS-232 command set No Issue Date Description Apply Firmware 1 2015/09/14 First version. v3.1.5.28 2 2018/04/27 1. RS-232 command(control Protocol) will respond ACK 2. RC pass-through
More informationICS 351: Today's plan. routing protocol comparison encapsulation network dynamics multicasting in general IP multicasting IGMP PIM
ICS 351: Today's plan routing protocol comparison encapsulation network dynamics multicasting in general IP multicasting IGMP PIM what routing is not: Ethernet switching does not use IP addresses in any
More informationTABLE OF CONTENTS 2/10
TABLE OF CONTENTS TABLE OF CONTENTS...2 1. OVERVIEW...3 1.1 RS485/RS232 SIGNALS...3 1.2 X10 SIGNALS...3 2. PROTOCOL...4 2.1 QUICK REFERENCE...4 2.1.1 PACKET DESCRIPTION...4 2.1.2 RS485/RS232 SIGNAL SENT
More informationDMPro Midi Sysex Specification v /25/99
DMPro Midi Sysex Specification v. 1.00 01/25/99 This document contains the system exclusive documentation for the DMPro SYSTEM EXCLUSIVE FORMAT...2 OPCODE SUMMARY:...2 OPCODES:...3 00h - MIDI User Drum
More informationPowerKey and PowerKey pro serier. J1939 Programmers Manual
PowerKey and PowerKey pro serier. J1939 Programmers Manual Summary: 1. How to connect CAN bus:... 2 2. Reference... 2 3. Message header description... 3 4. General Data Format... 3 5. Default Settings...
More informationIntel 8086 MICROPROCESSOR ARCHITECTURE
Intel 8086 MICROPROCESSOR ARCHITECTURE 1 Features It is a 16-bit μp. 8086 has a 20 bit address bus can access up to 2 20 memory locations (1 MB). It can support up to 64K I/O ports. It provides 14, 16
More informationWarm Up. Factor the following numbers and expressions. Multiply the following factors using either FOIL or Box Method
Warm Up Factor the following numbers and expressions 1. 36 2. 36x 3 + 48x 2 + 24x Multiply the following factors using either FOIL or Box Method 3. (3x 2)(x 1) 4. (x 2)(x + 3) Objectives Recognize standard
More informationCommunication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface
Communication protocols description of Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface Copyright: COMET System, Ltd. It is prohibited to copy and edit this manual and make any changes
More informationInstallation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter
Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Introduction The USB to Octal Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your
More informationCS-461 Internetworking. Dr. Mohamed Aboutabl
CS-461 Internetworking Dr. Mohamed Aboutabl http://www.cs.jmu.edu/users/aboutams The McGraw-Hill Companies, Inc., 2000 1 Chapter 1 Introduction The McGraw-Hill Companies, Inc., 2000 2 Internet today Network
More informationJ1939/Modbus Slave Gateway FAQ
J1939/Modbus Slave Gateway FAQ Version 1.0 (For GW-7228/GW-7238D) ICP DAS Co., Ltd. Table of Contents J1939/Modbus Slave Gateway FAQ v1.0 Q01 : How to solve CAN Bus Transmission Fail problem?... 2 Q02
More informationBack to. Communication Products Group. Technical Notes. Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit
Back to Communication Products Group Technical Notes 25T008 Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit MITEQ TECHNICAL NOTE 25T008 MAY 1997 REV D LOCAL/REMOTE
More informationGoGo Board Serial Protocol Revision 4.0.2
GoGo Board Serial Protocol Revision 4.0.2 2004 Future of Learning Group, MIT Media Laboratory. http://learning.media.mit.edu/ Arnan (Roger) Sipitakiat April 12, 2004 http://www.gogoboard.org General Information
More informationLecture 25 March 23, 2012 Introduction to Serial Communications
Lecture 25 March 23, 2012 Introduction to Serial Communications Parallel Communications Parallel Communications with Handshaking Serial Communications Asynchronous Serial (e.g., SCI, RS-232) Synchronous
More informationTechnical Documentation
Technical Documentation FAFNIR Universal Device Protocol Edition: 02/2018 Version: 1.09 Article no.: 350052 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40
More informationModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system
ModBus Communication protocol ModBus Communication Standards The ModBus protocol is an industrial communications and distributed control system to integrate PLCs, computers, terminals, and other monitoring,
More informationOPTRIS CT communication interface
OPTRIS CT communication interface 1. Serial interface parameters Protocol Baud rate: 9600 115200, set by user (factory default: 9600) Data bits: 8 Parity: none Stop bits: 1 Flow control: off The protocol
More informationCPE 448 Exam #2 (50 pts) April Name Class: 448
Name Class: 448 1) (5 pts) Draw the three way handshake used to establish a TCP connection. Show all SYN and ACK packets. Also show all sequence and acknowledgement numbers associated with the SYN and
More informationControlling the projector using a personal computer
MODEL UD740U Controlling the projector using a personal computer This projector can be controlled by connecting a personal computer with RS-232C terminal. PC-controllable functions: Turning the power ON
More informationSMD SERIES INVERTER MODBUS CONTROL OPERATION MANUAL. Document: SLmod-e2
SMD SERIES INVERTER MODBUS CONTRO OPERATION MANUA Document: Smod-e Table of Contents Scope.............................................................. Modbus Details.....................................................
More informationTechnical Note. SMART Command Feature Set for the eu500. Introduction. TN-FD-35: eu500 eusb SMART Commands. Introduction
Technical Note SMART Command Feature Set for the eu500 Introduction Introduction This technical note provides the self-monitoring, analysis, and reporting technology (SMART) command (B0h) feature set for
More informationAddressing Modes on the x86
Addressing Modes on the x86 register addressing mode mov ax, ax, mov ax, bx mov ax, cx mov ax, dx constant addressing mode mov ax, 25 mov bx, 195 mov cx, 2056 mov dx, 1000 accessing data in memory There
More informationChapter 1 Introduction Features Getting Help Chapter 2 ICB Architecture Layout and Components...
1 CONTENTS Chapter 1 Introduction... 2 1.1 Features... 2 1.2 Getting Help... 3 Chapter 2 ICB Architecture... 4 2.1 Layout and Components... 4 2.2 Block Diagram of the ICB... 5 Chapter 3 Board Components...
More informationDigital Projector X30N/X35N
Digital Projector X30N/X35N Operator's Guide TECHNICAL Warranty 3M warrants that when the 3M Product is used according to 3M s Intended Use Statement (www.3m.com/meetings), it will perform satisfactorily
More informationChapter 2 ICB Architecture Chapter 3 Board Components GPIO Interface RS-232 Interface RS-485 Interface...
1 CONTENTS Chapter 1 Introduction... 3 1.1 Features...3 1.2 About the Kit...4 1.3 Getting Help...5 Chapter 2 ICB Architecture... 6 2.1 Layout and Components...6 2.2 Block Diagram of the ICB...7 Chapter
More information4.6 Digital I/O and Relay Output Module Command
4050, 4052, 4053, 4060 Chapter 4 4.6 Digital I/O and Relay Output Module Command Command Syntax Command % AANNTTCCFF C onfiguration Sets the address, input range, baud rate, and/or checksum status, to
More informationTOSVERT VF-AS1 Series RS485 Communication Function Instruction Manual
TOSVERT VF-AS1 Series RS485 Communication Function Instruction Manual Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using
More information750/760 COMMUNICATIONS GUIDE. Digital Energy Multilin. Feeder Management Relay
Digital Energy Multilin 750/760 Feeder Management Relay COMMUNICATIONS GUIDE Software Revision: 7.3x GE Multilin Part Number: 1601-0229-A7 GE Publication Code: GEK-106473F Copyright 2010 GE Multilin GE
More information1. Communication Data Frame
Page : 1 1. Communication Data Frame EDX series inverter can be communication controlled by the PC or other controller with the communication protocol, Modbus ASCII Mode & Mode RTU, RS485 or RS232. Frame
More informationCustom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC
23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC ULTRA HIGH PRECISION DIGITAL TO ANALOGUE CONVERTER D33 44.1 48 88.2 1 2 96 176.4 192 1 OPTICAL 2 1
More informationFieldServer Driver - Serial FS Metasys N2
Driver Version: 1.02 Document Revision: 12 FieldServer Driver - Serial FS-8700-19 Metasys N2 Description The Metasys N2 network supports communications with a diverse range of devices. Many N2 compatible
More informationDescription. Feature. System Application Diagram
Description AO-FD FD-500 500-4LC LC-MX88 optical matrix bundle with AD-SL-500-4LC to achieve an image routing system, it is definitely saving 50% extenders cost and reducing complicated electrical cables
More informationPowerKey 1000 J1939 user manual
PowerKey 1000 J1939 user manual 1/15 PK1000_J1939_UM_REV1.0 www.blinkmarine.com Summary: 1. How to connect Deutsch 4 pin:... 3 2. Reference... 3 3. Message header description... 4 4. General Data Format...
More informationTCP/IP-2. Transmission control protocol:
TCP/IP-2 Transmission control protocol: TCP and IP are the workhorses in the Internet. In this section we first discuss how TCP provides reliable, connectionoriented stream service over IP. To do so, TCP
More informationIntroduction the Serial Communications Parallel Communications Parallel Communications with Handshaking Serial Communications
Introduction the Serial Communications Parallel Communications Parallel Communications with Handshaking Serial Communications o Asynchronous Serial (SCI, RS-232) o Synchronous Serial (SPI, IIC) The MC9S12
More informationDB-II Serial Communication Protocol Revision 0.2(English)
DB-II Serial Communication Protocol Revision 0.2(English) Final Revision: 2005. 4. 25 Page 1 3/2/2007 < Table of Contents > 1. The Serial Interface...3 1.1. Transmission Control Character...3 1.2. Synchronization...3
More informationINTELLIS. Modbus Direct Network Monitor
INTELLIS Modbus Direct Network Monitor System Installation and Operation Manual Phone: (201) 794-7650 Fax: (201)794-0913 Chapter 1 Modbus Protocol Revision History Revision 1.0 30 April, 2002 Initial Version
More informationThe I-7530A RS-232/485/422 to CAN Converter
The I-7530A RS-232/485/422 to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery
More informationINVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01:
INVERTER E510 Communication Addendum ModbusRTU/ASCI DOCUMENT-TECO-E510-AC001 Ver01:2015.03 Table of Contents 1.0 Modbus Protocol Description... 1-1 1.0.1 Communication Connection and Data Frame... 1-1
More informationControlling the projector using a personal computer
AUDIO OUT AUDIO IN-1 AUDIO IN-2 AUDIO IN-3L AUDIO IN-3R S-VIDEO VIDEO SERIAL MONITOR OUT COMPUTER / COMPONENT VIDEO IN-1 IN-2 USB-B USB-A DLP TM MODEL Projector XD550U/XD560U/WD570U/XD360U-EST/WD380U-EST/XD365U-EST/WD385U-EST
More informationTOSVERT VF-nC1 Communications Function Instruction Manual
TOSVERT VF-nC1 Communications Function Instruction Manual Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using the communications
More informationUSB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features
USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.
More informationACE24AC128 Two-wire Serial EEPROM
Description The ACE24AC128 series are 131,072 bits of serial Electrical Erasable and Programmable Read Only Memory, commonly known as EEPROM. They are organized as 16,384 words of 8 bits (one byte) each.
More informationTHT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE
COMMUNICATION INSTRUCTION MANUAL THT-500-A/R (C5) No. THT5CE2 2018.04 This manual contains instructions for communication functions of the THT-500-A/R. 1. System Configuration 1.1 When Using USB Communication
More informationDescription of communication protocols of Txxxx series
Description of communication protocols of Txxxx series DESCRIPTION OF COMMUNICATION PROTOCOLS... 3 MODBUS RTU... 3 Supported functions... 3 Jumper and button... 3 Description of supported function... 4
More informationD-ILA PROJECTOR RS-232C CONTROL SPECIFICATIONS. Victor Company of Japan, Limited. * D-ILA is a trademark of Victor Company of Japan, Limited.
D-ILA TM PROJECTOR DLA-G3010series DLA-M2000series RS-232C CONTROL SPECIFICATIONS Victor Company of Japan, Limited * D-ILA is a trademark of Victor Company of Japan, Limited. Document Number CTGKE-0013
More informationHDV100A3 Command Response Protocol
HDV100A3 Command Response Protocol Documentation Number: HDV100A3-4115m International Headquarters B+B SmartWorx 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General
More informationDatalogger and RS232 Interface
Datalogger and RS232 Interface RS232 Wiring Hardware 2 RS232 Code.. 3 Hardware Requirements and Setup 5 Software Requirements and Setup.. 6 Communicating Operation. 9 Run the Software......9 Record.. 11
More informationTOSVERT VF-nC3 Series RS485 Communication Function Instruction Manual
TOSVERT VF-nC3 Series RS485 Communication Function Instruction Manual Notice 1. Make sure that this instruction manual is delivered to the end user of the inverter. 2. Read this manual before first using
More informationJ1939 USER MANUAL POWERKEY PRO SERIES
J1939 USER MANUAL POWERKEY PRO SERIES PKP-2600-SI www.blinkmarine.com - info@blinkgroup.com Summary: 1. How to connect CAN bus:... 2 2. Reference... 2 3. Message header description... 3 4. General Data
More informationFlex Series User Guide
User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents
More informationRS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out.
RS 232 PINOUTS 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. 2. A DB9 Female to RJ12 Female Serial/Terminal Modular Adaptor
More informationHMS Anybus configuration setup
HMS Anybus configuration setup Installation of HMS Anybus Configuration Manager: For installation, please refer to the user manual for your selected Anybus Communicator and download the Anybus Configuration
More informationCS 16: Assembly Language Programming for the IBM PC and Compatibles
CS 16: Assembly Language Programming for the IBM PC and Compatibles Discuss the general concepts Look at IA-32 processor architecture and memory management Dive into 64-bit processors Explore the components
More informationMIDI Control for RedNet 4 and RedNet MP8R
MIDI Control for RedNet 4 and RedNet MP8R FFFA001405-02 Prerequisites Supported Mac or Windows PC RedNet 4 or RedNet MP8R hardware device Compatible MIDI controller (see MIDI Controllers) RedNet Control
More informationAnybus-CC Technical Introduction
Anybus-CC Technical Introduction Anybus Background From the beginning the functionality of an industrial network interface was primarily designed to exchange process data (I/O data). When Anybus was originally
More informationApplication Brief. Using the Total Phase CAN/I2C Activity Board Pro as an I2C- to- CAN Translator Application Brief by Rick Bogart
Using the Total Phase CAN/I2C Activity Board Pro as an I2C- to- CAN Translator Application Brief by Rick Bogart Introduction A customer request came in asking if we had a CAN to I2C translator. My first
More information8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.
8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments
More informationLZR -U920/U921 Protocol
LZR -U920/U921 Protocol Abbreviations LZR: laser scanner platform ToF: Time-of-Flight MDI: measured distance information 1. Introduction This application note contains useful information for communication
More informationStation 2. Inverter. PU connector (Note1)
using the E500 series drives General This data sheet describes the correct techniques for using E500 series inverters on a standard RS485 serial comms link. Up to 32 inverters may be connected. Max comms
More information6.6 VPN Tools Command Reference
6.6 VPN Tools Command Reference This section describes all commands that can be called when using vpncmd in Use VPN Tools Command (for example, certificate generating tools or traffic speed test tool)
More information1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2
1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol
More informationD I G I M A X BINARY COMMUNICATIONS PROTOCOL SYSTEM COMMAND AND CONTROL LANGUAGE APPLICATION MANUAL. Revision B1 April 30, 1993
D I G I M A X I V BINARY COMMUNICATIONS PROTOCOL SYSTEM COMMAND AND CONTROL LANGUAGE APPLICATION MANUAL Revision B1 April 30, 1993 POWERTEC Industrial Motors Mailing Address: P.O. Box 2650 * Rock Hill,
More informationINSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E
INSTRUCTION MANUAL FOR COMMUNICATION [OPTION CODE C5] GCSC3E1 2002.04 To prevent the accidents by mishandling of this controller, please arrange to give this manual into the hands of the operator who actually
More informationOB735 Smart Energy Meter
User Manual Revision 3.002 English OB735 Smart Energy Meter Benefits and Main Features Three phase metering Standard DIN rail Format (DIN43880) CI.1 Accuracy (EN50470) Energy consumption LED Isolated pulse
More informationComputer Networks and reference models. 1. List of Problems (so far)
Computer s and reference models Chapter 2 1. List of Problems (so far) How to ensure connectivity between users? How to share a wire? How to pass a message through the network? How to build Scalable s?
More information