1 OmniLT Version 2.9 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT INSTALLATION MANUAL Description The OmniLT Version 2.9 firmware adds the following new features: HAI Lighting Control (HLC) integration and support Modified the Fire Output Type to activate in a 3 pulse temporal pattern Note: Loading new firmware and screens into each OmniTouch touchscreen may be necessary to support new features in Version 2.9 Firmware. Ensure that each OmniTouch is running Screens Version 5. To check, press the Setup icon from the Home page. Next press the Screen Setup icon, followed by the Next button. The Screens Version should be displayed on the bottom left of the display. If the Screens Version is lower than 5 or if the text Screens Version is not displayed, use the Model 32A09-1 HAI OmniTouch Loader Kit utility to load new firmware and screens into the OmniTouch touchscreen. The OmniLT Version 2.8 firmware adds the following new feature (See Attached Addendum): Support for the Extended Range Temperature Sensor The OmniLT Version 2.7 firmware adds the following new feature (See Attached Addendum): Support for Lutron RadioRA Lighting Control The OmniLT Version 2.6 firmware adds the following new features (See Attached Addendum): Support for UPB (Universal Powerline Bus) Technology Added ability to disable Bypass/Restore digital communicator reports when using Contact ID Added ability to disable individual digital communicator zone reports when using Contact ID About HAI Lighting Control (HLC) HAI Lighting Control (HLC) combines HAI UPB Wall Switches, Dimmers, and Modules, HAI UPB Room Controllers, and HAI UPB House Controllers to create lighting scenes that set the proper mood and ambiance for various activities. HLC format is a defined structure for configuring, programming, and operating all the HLC lighting devices in your home. HLC uses UPB technology which is a new powerline communications standard for lighting and home control. UPB is a robust, two-way digital powerline carrier communications protocol which transmits signals over the existing wires in a home. Home Automation, Inc. New Orleans, LA Phone Fax

2 HLC Setup The following OmniLT Setup items must be configured for HLC: UPB Network ID: The Network ID is a unique number between 1 and 255 which identifies your UPB Network. To configure the UPB Network ID, from the Setup>>Installer>>Control menu, select the 1 (CTRL) key. Scroll to UPB Network ID: UPB NETWORK ID: Enter the UPB Network ID (1-255) followed by the ' # ' key. UPB Password: The Network Password is a 4-digit number between 0001-FFFF that is used to protect your UPB network from unauthorized changes to the internal settings of your UPB devices. UPB PASSWORD: FFFF Enter the UPB Password (0000-FFFF) followed by the ' # ' key. To enter the digits A-F, first press the OFF key, then press the 0-5 key respectively (i.e. 1A2B = 1 OFF 0 2 OFF 1 #). UPB Status Time (Status Tracking): When using HLC, Status Tracking is used to update the status of each HLC device in a room whenever a scene is executed in that room. For example, the scene A button is pushed on a Room Controller in the Living Room. All of the lighting loads in the Living Room are changed, but the status for the individual lighting loads isn t updated in OmniLT until a status request message is sent to each unit. When Status Tracking is enabled, this is done automatically after a scene is executed. The value set for the UPB Status Time is the amount of seconds that the OmniLT controller waits before requesting status after a scene is executed. By default, the time is set to 5 seconds. This gives lighting loads (with varying fade rates) the necessary time to settle down before the status is requested. UPB STATUS TIME: SECONDS Enter for 1 to 255 seconds. Enter 0 to disable Status Tracking. Note: Status Tracking must be enabled for OmniLT to accurately set the LED indicators on Room and House Controllers. Page 2

3 HAI Lighting Control (HLC) Format When configured to use the HLC format, OmniLT can control up to 16 HLC devices. Each HLC device (Switch, Dimmer, Module, Room Controller, or House Controller) has its own Unit ID (1-16). When configured to use the HLC format, OmniLT consists of 2 rooms of lighting with up to 8 HLC devices in each room. To configure House Codes to the HLC Format, from the Set Up menu, press the 6 (MISC) key. House Code 1 Format House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's Compose Mode, UPB (open transmission format), Lutron s RadioRA transmission format, and HAI Lighting (HLC) format. HC 1 FORMAT: 1 1=EXTENDED #=CHNG To change format to HLC for House Code 1, press the ' # ' key, and then use the arrow keys to scroll through the list of formats until HAI LIGHTING is displayed. Press the ' # ' key to select. Press the down-arrow key to change format for the next House Code. FORMAT NUMBER DESCRIPTION STANDARD 0 Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.) EXTENDED 1 Extended Code Level Command (Leviton) COMPOSE 2 Compose Mode (Lightolier's Compose) UPB 3 Universal Powerline Bus (open format) RADIO RA 4 Lutron RadioRA HAI LIGHTING 5 HAI Lighting Control (HLC) Configuring Serial Communications for HLC When connecting the HAI Model 36A00-1 Powerline Interface Module (for HLC/UPB communications) to a serial interface on the OmniLT controller, the serial interface must be configured to the respective protocol. Serial Module Setup When connecting the HAI Model 36A00-1 Powerline Interface Module to the HAI Model 10A17 Serial Interface Module, the Module Type must configured as follows: From the Installer Setup menu, select the 7 (EXP) key. The Module Type defines the function of each expansion module on the controller. Module 1 is the module with the ADDR jumper set to 1. Set the module type from the list below. Press ' # ' to change the module type, then use the arrow keys to select the proper module type, then press ' # ' to enter: MODULE 1 TYPE 5 UPB #=CHNG For HLC/UPB communications: set the Serial Interface Module to 5 (UPB). Page 3

4 For example when configuring the module to UPB and if the jumper on the Serial Interface Module is set to 1, set Module 1 Type to 5 (UPB). The Serial Interface Module is now set to use the UPB Protocol. MODULE TYPES NUMBER DESCRIPTION NOT USED 0 No module is installed HARDWIRE EXPNDR 1 Model 10A06 Hardwire Expander installed ALC 2 ALC Interface Module is installed OMNI-LINK 3 Model 10A17 Serial Interface using the Omni-Link protocol PRO-LINK 4 Model 10A17 Serial Interface using the Pro-Link protocol UPB 5 Model 10A17 Serial Interface using the UPB protocol Serial Function When connecting the HAI Model 36A00-1 Powerline Interface Module to the built-in serial port on the OmniLT, the "Serial Function" selects the communication protocol that is used. Serial 1 Function Select the function for the built-in serial interface from the list. Use the arrow keys to select the function then press the ' # ' key. FUNCTION TYPES NUMBER DESCRIPTION OMNI-LINK 3 Serial communication using the Omni-Link protocol PRO-LINK 4 Serial communication using the Pro-Link protocol UPB 5 Serial communication using the UPB protocol Fire Output Type A Fire Output is used to trigger sirens, internal sounders in smoke detectors (when used with a reversing relay), and voice drivers when a fire alarm occurs. In OmniLT Controller Firmware prior to Version 2.9, the output generated a steady 12VDC output. To accommodate codes and ordinances that require annunciation devices to activate in a 3 pulse temporal pattern, the Fire Output now generates 12VDC in a 3 pulse temporal pattern. Page 4

5 OmniLT Version 2.8 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT INSTALLATION MANUAL Description The OmniLT Version 2.8 firmware adds the following new feature: Support for the Extended Range Temperature Sensor The OmniLT Version 2.7 firmware adds the following new feature (See Attached Addendum): Support for Lutron RadioRA Lighting Control The OmniLT Version 2.6 firmware adds the following new features (See Attached Addendum): Support for UPB (Universal Powerline Bus) Technology Added ability to disable Bypass/Restore digital communicator reports when using Contact ID Added ability to disable individual digital communicator zone reports when using Contact ID Extended Range Temperature Sensors The Model 31A00-7 Extended Range Temperature Sensor and the Model 31A00-8 Extended Range and Humidity Sensor is used for sensing temperatures from -40 o F o F. Extended Range Temperature sensors can be used for outdoors or in attics, garages, greenhouses, basements, wine cellars, coolers, and freezers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high setpoint or drops below the low setpoint programmed in the system. Each Model 31A00-7 and Model 31A00-8 requires one zone input on the OmniLT controller or Expander Module for temperature. Additionally, the Model 31A00-8 requires one zone input for humidity. The following new Zone Types have been added for Extended Range Temperature Sensors: ZONE TYPE NUMBER DESCRIPTION OUTDOOR TMP 81 Outdoor Temperature TEMPERATURE 82 Temperature TEMP ALARM 83 Temperature Alarm HUMIDITY 84 Humidity ER OUTDOOR TMP 85 Extended Range Outdoor Temperature ER TEMPERATURE 86 Extended Range Temperature ER TEMP ALARM 87 Extended Range Temperature Alarm Home Automation, Inc. New Orleans, LA Phone Fax

6 Page 6

7 OmniLT Version 2.7 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT INSTALLATION MANUAL Description The OmniLT Version 2.7 firmware adds the following new feature: Support for Lutron RadioRA Lighting Control The OmniLT Version 2.6 firmware adds the following new features (See Attached Addendum): Support for UPB (Universal Powerline Bus) Technology Added ability to disable Bypass/Restore digital communicator reports when using Contact ID Added ability to disable individual digital communicator zone reports when using Contact ID Lutron RadioRA uses wireless communication technology to control lighting. Each Switch or Dimmer controls one Zone, or area, of lighting in a RadioRA system. A Zone is any individual RadioRA Switch or Dimmer. A RadioRA System has a maximum of 32 Zones. Zone Numbers can be used to identify any individual Zone (one Switch or one Dimmer), in a RadioRA system via the RS232 Interface. The Chronos System Bridge and Timeclock bridges two RadioRA systems for a total of 64 Lighting Zone Controls and 24 Master Controls. However, OmniLT can only control 16 total RadioRA devices. Required Equipment HAI OmniLT, OmniLT, or OmniPro II Controller: Version 2.7 or later firmware is required. HAI Model 10A17-1 Serial Interface Module: Model 10A17-1 Serial Interface Module with straight thru serial cable (DB9M/F). Upgrade Kits are available with Firmware Upgrade, Serial Interface Module, and Serial Cable: RR OMNILT KIT - RadioRA Connection Kit for OMNILT RR OMNILT KIT - RadioRA Connection Kit for OmniLT RR OMNILT KIT - RadioRA Connection Kit for OmniLT Lutron RadioRA RS-232 Interface (RA-RS232) OR Chronos System Bridge and Timeclock (RA-SBT-CHR): The RS-232 Interface allows for integration with HAI controllers. The Chronos bridges two RadioRA systems and provides an RS-232 interface for integration with HAI controllers. Lutron RadioRA Switches, Dimmers, and Master Controls: Available from Lutron distributors. Home Automation, Inc. New Orleans, LA Phone Fax

8 RadioRA Setup The following OmniLT Setup items must be configured for use with RadioRA: Serial Setup The RadioRA RS-232 Interface (RA-RS232) or Chronos System Bridge (RA-SBT-CHR) connects to the OmniLT to either the builtin serial port on the controller or to the Model 10A17 Serial Interface Module. When connected to the built-in serial port, the Serial Function must be configured. When the Model 10A17 Serial Interface Module is used, the Module Type must be configured for the respective expansion module address. Only one interface (built-in port or 10A17 Serial Interface) may be set to RadioRA. Serial Module Setup When used, the 10A17 Serial Interface Module (supplied with the RadioRA Upgrade Kit) must be configured to use the RadioRA protocol. From the Installer Setup menu, select the 7 (EXP) key. The Module Type defines the function of each expansion module on the controller. Module 1 is the module with the ADDR jumper set to 1. Set the module type from the list below. Press ' # ' to change the module type, then use the arrow keys to select the proper module type, then press ' # ' to enter: MODULE 1 TYPE 6 RADIO RA #=CHNG Set the Serial Interface Module to RadioRA. For example, if the jumper on the Serial Interface Module is set to 1, set Module 1 Type to 6 (RADIO RA). The Serial Interface Module is now set to use the RadioRA Protocol. MODULE TYPES NUMBER DESCRIPTION NOT USED 0 No module is installed HARDWIRE EXPNDR 1 Model 10A06 Hardwire Expander installed ALC 2 ALC Interface Module is installed OMNI-LINK 3 Model 10A17 Serial Interface using the Omni-Link protocol PRO-LINK 4 Model 10A17 Serial Interface using the Pro-Link protocol UPB 5 Model 10A17 Serial Interface using the UPB protocol RADIO RA 6 Model 10A17 Serial Interface using the RadioRA protocol Plug one end of the straight thru serial cable (supplied with the RadioRA Upgrade Kit) into the RadioRA RS-232 Interface (RA- RS232) or Chronos System Bridge (RA-SBT-CHR) and the other end into the DB-9 connector (J2) on the 10A17 Serial Interface Module. Serial Function Setup When used, the built-in serial port must be configured to use the RadioRA protocol. The Serial Function defines the function (i.e. protocol) of the built-in serial port. Press ' # ' to change the module type, then use the arrow keys to select the proper module type, then press ' # ' to enter: SERIAL 1 FUNCTION 6 RADIO RA #=CHNG Set the Serial Function to RadioRA. The serial port is now set to use the RadioRA Protocol. Page 8

9 Enabling the RadioRA House Code OmniLT can control up to 16 RadioRA devices. To configure the RadioRA House Code, from the Set Up menu, press the 6 (MISC) key. House Code 1 Format House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's Compose Mode, UPB, and RadioRA transmission format. HC 1 FORMAT: 1 1=EXTENDED #=CHNG To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats. Press the ' # ' key to select a new type. FORMAT NUMBER DESCRIPTION STANDARD 0 Preset Dim Command (X-10, X-10 Pro, PCS, etc.) EXTENDED 1 Extended Code Level Command (Leviton) COMPOSE 2 Compose Mode (Lightolier's Compose) UPB 3 Universal Powerline Bus RADIO RA 4 Lutron RadioRA The default setting for HC 1 Format is 1. Page 9

10 OmniLT Version 2.6 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT INSTALLATION MANUAL Description The OmniLT Version 2.6 firmware adds the following new features: Support for UPB (Universal Powerline Bus) Technology Added ability to disable Bypass/Restore digital communicator reports when using Contact ID Added ability to disable individual digital communicator zone reports when using Contact ID UPB is a new powerline communications standard for lighting and home control. UPB is a robust, two-way digital powerline carrier communications protocol which transmits signals over the existing wires in a home. UPB signals are transmitted using a digital pulse (pulse position modulation) instead of a 120 khz tone over the existing house wiring. The UPB pulse has a broad frequency spectrum, about 4 to 40 khz, which travels better on the powerline. Attenuation on the powerline is lower at UPB frequencies and less susceptible to noise. UPB can coexist peacefully with X-10 systems, intercoms, baby monitors, speakers, etc. that communicate over the powerline. Required Equipment HAI OmniLT, OmniLT, or OmniPro II Controller: Version 2.6 or later firmware is required. HAI Model 10A17-1 Serial Interface Module: The PCS Serial PIM will not work with built-in serial ports on the OmniLT controller. It must be used with the Model 10A17-1 Serial Interface Module. UPB Powerline Interface Module Serial (PIM-S): Available from PCS and/or its distributors. To work with OmniLT, the PIM must be Version 4.15 or later and it must be the Serial version (not the USB version). The PCS Serial PIM comes with the proper cable for the 10A17-1 Serial Module. UPB Switches, Modules, and/or Keypad Controllers: Available from PCS and/or its distributors. UPB UPStart Setup Tool Software: Free download from PCS ( UPB switches, modules, and keypad controllers are configured using the UPB UPStart program running on a PC while connected to the PIM. Instructions on installing, configuring, and operating UPB UPStart and PCS UPB devices are available from PCS. This document will give you some general guidelines for configuring UPB devices with UPB UPStart for optimal communications with the OmniLT controller. Note: Although the UPB protocol is extremely robust and less susceptible to powerline conditions, for professional installations, HAI recommends the use of a UPB Phase Coupler. Home Automation, Inc. New Orleans, LA Phone Fax

11 UPB Setup The following OmniLT Setup items must be configured for use with UPB: UPB Network ID: A new item has been added to Setup>>Installer>>Control to set the Network ID for the UPB network. The Network ID must be the same as the one that is established using the UPStart software. From the Installer Setup menu, select the 1 (CTRL) key. Scroll to the Network ID setting: UPB NETWORK ID: Enter the Network ID (1-255) followed by the ' # ' key. UPB Password: The UPB Password must be the same as the one established using the UPStart software. UPB PASSWORD: FFFF Enter the UPB Password (0000-FFFF) followed by the ' # ' key. Serial Module Setup The 10A17 Serial Interface Module must be configured to the UPB protocol. From the Installer Setup menu, select the 7 (EXP) key. The Module Type defines the function of each expansion module on the controller. Module 1 is the module with the ADDR jumper set to 1. Set the module type from the list below. Press ' # ' to change the module type, then use the arrow keys to select the proper module type, then press ' # ' to enter: MODULE 1 TYPE 5 UPB #=CHNG Set the Serial Interface Module to UPB. For example, if the jumper on the Serial Interface Module is set to 1, set Module 1 Type to 5 (UPB). The Serial interface Module is now set to use the UPB Protocol. MODULE TYPES NUMBER DESCRIPTION NOT USED 0 No module is installed HARDWIRE EXPNDR 1 Model 10A06 Hardwire Expander installed ALC 2 ALC Interface Module is installed OMNI-LINK 3 Model 10A17 Serial Interface using the Omni-Link protocol PRO-LINK 4 Model 10A17 Serial Interface using the Pro-Link protocol UPB 5 Model 10A17 Serial Interface using the UPB protocol Plug one end of the serial cable (supplied with the PCS Serial PIM) into the PIM and the other end into the DB-9 connector (J2) on the 10A17 Serial Interface Module. Page 11

12 Note: After connecting the PCS Serial PIM to the HAI Serial Interface Module, if the Receive LED on the HAI Serial Interface Module is on steady, the PIM is likely in Pulse Mode. HAI controllers use the Powerline Interface Module (PIM) in Message Mode. While Message Mode is the factory default mode of the PCS Serial PIM, the PCS UPStart application uses the Pulse Mode of the PIM. When connected to the HAI Serial Interface Module, the PIM can manually be put into Message Mode using the Program pushbutton on the PIM as follows: Setting the PCS Serial PIM to Message Mode Step Operation 1 Press the Program pushbutton five (5) times quickly in a row. 2 The LED should start to blink green to indicate it is in Setup Mode. 3 Press the Program pushbutton ten (10) times quickly in a row. 4 The LED should start to blink red to indicate that the Factory Defaults have been set. 5 Press the Program pushbutton one (1) more time. 6 The LED should stop blinking to indicate that it is ready for normal operation. *Repeat these steps after every use of the PIM with the PCS UPStart application. Enabling the UPB House Code OmniLT can control up to 16 UPB devices. Each UPB device (switches, modules, and keypad controllers) has its own Unit ID (1-16). To configure the UPB House Code, from the Set Up menu, press the 6 (MISC) key. House Code 1 Format: House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's Compose Mode, and UPB transmission format. HC 1 FORMAT: 1 1=EXTENDED #=CHNG To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats. Press the ' # ' key to select a new type. FORMAT NUMBER DESCRIPTION STANDARD 0 Preset Dim Command (X-10, X-10 Pro, PCS, etc.) EXTENDED 1 Extended Code Level Command (Leviton) COMPOSE 2 Compose Mode (Lightolier's Compose) UPB 3 Universal Powerline Bus The default setting for HC 1 Format is 1. Page 12

13 Digital Communicator Setup Report Bypass / Restore: A new item has been added to Setup>>Installer>>DCM to enable/disable reporting to the central station when a zone is bypassed or restored when using Contact ID. The communicator can be configured to send bypass/restore signals to the central station when using Contact ID. Whenever a zone is bypassed, the communicator will send a zone bypassed report to the central station. When a zone is restored, the communicator will send a zone restored report to the central station. REPORT BYPASS/REST: 1 0=NO 1=YES To disable the communicator from sending bypass and restore reports to the central station, select the 0 (NO) key. Disable Individual Zone Reports: A new feature has been added that allows you to disable digital communicator reporting for specific zones when using Contact ID. Previously, Contact ID reports whenever any zone is tripped, goes in trouble, or is bypassed and restored. Now, a zone can be configured to never report when a zone is tripped, goes into trouble, or is bypassed and restored. When using Contact ID, if the DCM code (under the 4/2 and 3/1 Alarm Code Formats) is set to anything other than 0 or 00, then OmniLT reports the typical Contact ID report code. However, if the DCM code (under the 4/2 and 3/1 Alarm Code Formats) is set to 0 or 00, then OmniLT will not make a call to the central station to report that code. To disable digital communicating reporting for a specific zone, set the alarm code to 0 or 00. ZONE 1 ALARM CODE: 00 0-FF THROUGH ZONE 25 ALARM CODE: 00 0-FF Enter the alarm code (0 or 00) and then press ' # ' to disable the zone from reporting to the central station. Page 13

OmniPro II Version 2.11 Firmware Release

OmniPro II Version 2.11 Firmware Release OmniPro II Version 2.11 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II INSTALLATION MANUAL Description The OmniPro II Version 2.11 firmware adds the following new feature: Support for OmniTouch

More information

OmniPro II Version 2.7 Firmware Release

OmniPro II Version 2.7 Firmware Release OmniPro II Version 2.7 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II INSTALLATION MANUAL Description The OmniPro II Version 2.7 firmware adds the following new feature: Support for Lutron RadioRA

More information

OmniLT Version 2.10 Firmware Release

OmniLT Version 2.10 Firmware Release OmniLT Version 2.10 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT OWNER S MANUAL Description The OmniLT Version 2.10 firmware adds the following new features: Support for the CentraLite LiteJet and

More information

Omni II Version 2.10 Firmware Release

Omni II Version 2.10 Firmware Release Omni II Version 2.10 Firmware Release ADD THIS DOCUMENT TO YOUR OMNI II OWNER S MANUAL Description The Omni II Version 2.10 firmware adds the following new features: Support for the CentraLite LiteJet

More information

Omni II Version 2.9 Firmware Release

Omni II Version 2.9 Firmware Release Omni II Version 2.9 Firmware Release ADD THIS DOCUMENT TO YOUR OMNI II OWNER S MANUAL Description The Omni II Version 2.9 firmware adds the following new features: HAI Lighting Control (HLC) integration

More information

OmniPro II Version 2.8 Firmware Release

OmniPro II Version 2.8 Firmware Release OmniPro II Version 2.8 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II OWNER S MANUAL Description The OmniPro II Version 2.8 firmware adds the following new feature: Support for the Extended Range

More information

OmniLT Version 2.6 Firmware Release

OmniLT Version 2.6 Firmware Release OmniLT Version 2.6 Firmware Release ADD THIS DOCUMENT TO YOUR OMNILT OWNER S MANUAL Description The OmniLT Version 2.6 firmware adds the following new feature: Support for UPB (Universal Powerline Bus)

More information

OmniPro II Version 2.11 Firmware Release

OmniPro II Version 2.11 Firmware Release OmniPro II Version 2.11 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II OWNER S MANUAL Description The OmniPro II Version 2.11 firmware adds the following new features: Support for OmniTouch with

More information

OmniPro II Version 2.14 Firmware Release

OmniPro II Version 2.14 Firmware Release OmniPro II Version 2.14 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II OWNER S MANUAL Description The OmniPro II Version 2.14 firmware adds the following new features: Support for Z-Wave technology

More information

Lumina Version 2.15 Firmware Release

Lumina Version 2.15 Firmware Release Lumina Version 2.15 Firmware Release ADD THIS DOCUMENT TO YOUR LUMINA ADVANCED APPLICATION GUIDE Description The Lumina Version 2.15 firmware adds the following new features: Support for DSC Power Series

More information

HAI Distributor Availability October 2005

HAI Distributor Availability October 2005 OmniLT Controllers 21A00-1 Omni LT Controller Omni LT controller with enclosure, RJ31X jack and cable,, accessory kit. 21A00-2 Omni LT Board Only Omni LT controller board only 21A00-11 Omni LT for Structured

More information

The Lumina has an astronomical clock and automatically adjusts for daylight savings time in order to provide accurate dusk to dawn lighting control.

The Lumina has an astronomical clock and automatically adjusts for daylight savings time in order to provide accurate dusk to dawn lighting control. Lumina Technical Sheet Now includes flash memory for easy firmware updates and five serial ports. DESCRIPTION The Lumina is a central lighting and automation controller. Lumina provides elegance and convenience

More information

OmniPro II Version 3.0 Firmware Release

OmniPro II Version 3.0 Firmware Release OmniPro II Version 3.0 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II INSTALLATION MANUAL Description The OmniPro II Version 3.0 firmware adds the following new features: OmniTouch menu operation

More information

Lumina Pro Version 2.15 Firmware Release

Lumina Pro Version 2.15 Firmware Release Lumina Pro Version 2.15 Firmware Release ADD THIS DOCUMENT TO YOUR LUMINA PRO ADVANCED APPLICATION GUIDE Description The Lumina Pro Version 2.15 firmware adds the following new features: Support for DSC

More information

OmniPro II Version 3.1 Firmware Release

OmniPro II Version 3.1 Firmware Release OmniPro II Version 3.1 Firmware Release ADD THIS DOCUMENT TO YOUR OMNIPRO II OWNER S MANUAL Description The OmniPro II Version 3.1 firmware adds the following new features: Added HAI Trigger messages for

More information

The Omni IIe Controller

The Omni IIe Controller The Omni IIe Controller Omni IIe is an ideal and economical choice for homes and small businesses. The system provides enhanced comfort, safety, convenience and energy savings by coordinating audio, lighting,

More information

HAI Part Numbers and Descriptions March, 2003

HAI Part Numbers and Descriptions March, 2003 OmniLT Controllers 21A00-1 OmniLT Controller OmniLT controller with enclosure, RJ31X jack and cable, manuals, accessory kit. 21A00-2 OmniLT Board Only OmniLT controller board only 21A00-11 OmniLT for Leviton

More information

Home Automation, Inc. Omni-Link. Serial Protocol Description

Home Automation, Inc. Omni-Link. Serial Protocol Description Home Automation, Inc. Omni-Link Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes the use of this information for the sole purpose

More information

Lumina Version 3.0 Firmware Release

Lumina Version 3.0 Firmware Release Lumina Version 3.0 Firmware Release ADD THIS DOCUMENT TO YOUR LUMINA ADVANCED APPLICATION GUIDE Description The Lumina Version 3.0 firmware adds the following new features: UPB Transmit Count to increase

More information

Serial Interface Module

Serial Interface Module OnQ 363737-01 Serial Interface Module DESCRIPTION The 363737-01 Serial Interface can be used with Model 925 or Model 1050 controller. It allows the controller to be connected to a personal computer or

More information

Home Automation, Inc. Omni-Link. Serial Protocol Description

Home Automation, Inc. Omni-Link. Serial Protocol Description Home Automation, Inc. Omni-Link Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes the use of this information for the sole purpose

More information

HLC. Omnistat2. Technical Sheet. Elegant, Reliable Lighting Control at an Affordable Price! 1

HLC. Omnistat2. Technical Sheet. Elegant, Reliable Lighting Control at an Affordable Price!  1 Omnistat2 HLC Technical Sheet Elegant, Reliable Lighting Control at an Affordable Price! Dim lights as movie begins, using the convenient remote control. Lighting control can enhance the enjoyment and

More information

HOME AUTOMATION, INC. Lumina Lighting and Automation System. Advanced Application Guide

HOME AUTOMATION, INC. Lumina Lighting and Automation System. Advanced Application Guide HOME AUTOMATION, INC. Lumina Lighting and Automation System Advanced Application Guide Document Number 44R00-1 Rev. 2.12 March, 2006 Copyright 2001-2006 Home Automation, Inc. All Rights Reserved Contents

More information

USING UPB LIGHTING DEVICES WITH HOMEVISION OR HOMEVISION-PRO

USING UPB LIGHTING DEVICES WITH HOMEVISION OR HOMEVISION-PRO USING UPB LIGHTING DEVICES WITH HOMEVISION OR HOMEVISION-PRO 1.0 INTRODUCTION This application note details how to use Universal Powerline Bus (UPB) lighting devices from Powerline Control Systems with

More information

HomeSeer UPB Plug-in Documentation Version

HomeSeer UPB Plug-in Documentation Version HomeSeer UPB Plug-in Documentation Version 1.0.2.4 The HomeSeer UPB Plug-in allows HomeSeer (Version 2.0 Build 1972 or higher) to communicate with and control UPB (Universal Powerline Bus) devices. HomeSeer

More information

Lumina Pro WEB VERSION. Advanced Application Guide. Lighting and Automation System

Lumina Pro WEB VERSION. Advanced Application Guide. Lighting and Automation System Lumina Pro Lighting and Automation System Advanced Application Guide Contents * INTRODUCTION... 1 Planning... 1 INSTALLATION... 2 Mount the Lumina Enclosure... 3 Ground the Lumina Controller... 3 Connect

More information

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION Power Hub Cat. No. 83A00-1 Installation Manual WARNINGS AND CAUTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water

More information

A Quick Start Guide to using Universal Powerline Bus devices

A Quick Start Guide to using Universal Powerline Bus devices Introduction A Quick Start Guide to using Universal Powerline Bus devices Universal Powerline Bus (UPB) is a state of the art home automation control system that uses the existing AC powerline within your

More information

Home Automation, Inc. Omni-Link II. Protocol Description

Home Automation, Inc. Omni-Link II. Protocol Description Home Automation, Inc. Omni-Link II Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes the use of this information for the sole purpose

More information

ELK-M1XSP INSTALLATION MANUAL

ELK-M1XSP INSTALLATION MANUAL -MXSP ing Interface, Thermostat Interface, and Serial Port Expander INSTALLATION MANUAL IMPORTANT NOTICE: Every effort has been made to assure the accuracy of the information contained in this document

More information

ELK-M1XSP INSTALLATION MANUAL

ELK-M1XSP INSTALLATION MANUAL -MXSP ing Interface, Thermostat Interface, and Serial Port Expander INSTALLATION MANUAL IMPORTANT NOTICE: Every effort has been made to assure the accuracy of the information contained in this document

More information

Appendix 8 Universal Powerline Bus (UPB)

Appendix 8 Universal Powerline Bus (UPB) Appendix 8 Universal Powerline Bus (UPB) This appendix describes the features in HCA in support of the UPB technology and products available from Powerline Control Systems (PCS), Simply Automated Inc,

More information

Installation Instructions

Installation Instructions NX-148E-RF LCD Touchpad w/receiver 466-2198 Rev. B May 2005 Product summary The NX-148E-RF Touchpad w/receiver combines touchpad and receiver capabilities into a single device for use with NetworX NX-4,

More information

M2DIS. User Manual.

M2DIS. User Manual. M2DIS User Manual www.audac.eu 2 Index Introduction 4 Caution servicing 4 User interface 5 Login screen 5 Main screen 6 Output settings 8 Test signals 10 Sound settings 11 Settings screen 12 Input Configuration

More information

PROGRAMMING HELP GUIDE

PROGRAMMING HELP GUIDE DIGIPLEX EVO48-192 PROGRAMMING HELP GUIDE Entering Programming Mode 1) Press and hold the [0] key 2) Enter your [Installer Code] (default-000000) 3) Enter 4-digit [section] you wish to program 4) Enter

More information

Integrating LaunchPort AM.2 Sleeve Buttons w/ Lutron Systems 1.0 Overview

Integrating LaunchPort AM.2 Sleeve Buttons w/ Lutron Systems 1.0 Overview Integrating LaunchPort AM.2 Sleeve Buttons w/ Lutron Systems 1.0 Overview The LaunchPort, from Dana Innovations, consists of a Station and a Sleeve that allows the user to mount and charge an ipad anywhere

More information

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 FEATURE DEFINITIONS... 3 TERMINAL DRAWING AND SPECIAL

More information

TM50 Touch Intuitive Touchscreen

TM50 Touch Intuitive Touchscreen TM50 Touch Intuitive Touchscreen Description With its bright color display, intuitive icons, and menu-driven interface, the TM50 Touch Intuitive Touchscreen reflects Paradox s commitment to user-centric

More information

ADEMCO LYNXR-ENSIA Security System

ADEMCO LYNXR-ENSIA Security System UL K5966-2 9/06 Rev. A ADEMCO LYNXR-ENSIA Security System Quick Start Guide LYNXR-ENSIA is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed.

More information

Converging Systems Inc.

Converging Systems Inc. Converging Systems Inc. e-node Lutron e-node Interfacing with Lutron Guide Version 1.02 Revision History Date Version Description Author 10/01/2012 1.0 Consolidated Version AD 10/10/2012 1.01 Enhancements

More information

Home Automation, Inc. Model 32A00-5. OmniTouch with Video Touchscreen

Home Automation, Inc. Model 32A00-5. OmniTouch with Video Touchscreen Home Automation, Inc. Model 32A00-5 OmniTouch with Video Touchscreen Installation Manual Document Number 32I00-5 Rev A November, 2005 PLANNING In selecting a place to mount the touchscreen, be sure to

More information

HomeSeer Authorized Dealer Program

HomeSeer Authorized Dealer Program HomeSeer Authorized Dealer Program Integrators who wish to be become authorized HomeSeer dealers must purchase one of the following dealer start-up bundles and complete our online web training. HomeSeer

More information

Wireless Expander Eclipse WL Installation and Programming Manual

Wireless Expander Eclipse WL Installation and Programming Manual Wireless Expander Eclipse WL Installation and Programming Manual 1. General Information Eclipse WL is a wireless expander module designed for building of hybrid systems with wired control panels Eclipse

More information

Universal Powerline Bus

Universal Powerline Bus Universal Powerline Bus X-10 To UPB Migration Document V 1.1 09/25/03 Page i Table Of Contents 1. Overview...1 1.1. Scope...1 2. Review Of The Protocols...2 2.1. Physical Methods...2 2.2. Device Addressing...2

More information

LynX-10 PLC Bi-directional X-10 Interface Quick Start Manual version 1.20

LynX-10 PLC Bi-directional X-10 Interface Quick Start Manual version 1.20 LynX-10 PLC Bi-directional X-10 Interface Quick Start Manual version 1.20 Model: 105 Marrick Limited LynX-10 TM PLC Manual revision 1.20 Marrick Limited, Incorporated P.O. Box 950940 Lake Mary, FL 32795

More information

Omni-Bus Scene Controller

Omni-Bus Scene Controller Omni-Bus Scene Controller Reference Manual Document Number: 126R00-1, Rev 1.0.0 Copyright Table of Contents 1. Overview... 3 2. Scene Controller Channel Setup... 4 2.1. Enabling and Disabling Scenes...

More information

May 7, :27:07 e ESC FORWARD/ DISPLAY CALLS REDIAL PAGE ALL SOURCE SELECTED HOLD ROOMS SPEAKER CANCEL/ CLEAR PHONE PTT/ ENTER TROUBLE

May 7, :27:07 e ESC FORWARD/ DISPLAY CALLS REDIAL PAGE ALL SOURCE SELECTED HOLD ROOMS SPEAKER CANCEL/ CLEAR PHONE PTT/ ENTER TROUBLE May 7, 0 5:7:07 e00 000 SOURCE HOLD / CLEAR PAGE X ESC ALL ROOMS PHONE PTT/ ENTER FORWARD/ DISPLAY S REDIAL www.mytelecor.com eseries Version.0 Telecor is excited to announce additions to its eseries product

More information

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video Home Automation, Inc. Model 53A00-1 OmniTouch 5.7 Touchscreen with Video Installation Manual Document Number 53I00-1 Rev A June, 2007 FCC NOTICE This device complies with FCC Rules Part 15. Operation is

More information

application software

application software application software application software RF input product Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices 8565 52 xx 8565 62

More information

HOME AUTOMATION. Cross Platform Controller Kits M1 Gold Kits. M1 Keypads Keypads. Expanders & Interface Moduals Expander Moduals

HOME AUTOMATION. Cross Platform Controller Kits M1 Gold Kits. M1 Keypads Keypads. Expanders & Interface Moduals Expander Moduals Cross Platform Controller Kits M1 Gold Kits NESS 250-251 EZ24 Kits Ness 252-253 M1 Keypads Keypads NESS 254 Accessories NESS 255 Expanders & Interface Moduals Expander Moduals NESS 256-258 Installation

More information

Programming Default Tables

Programming Default Tables Lynx Plus Control Defaults Lynx Plus Series Installation and Setup Guide *20 Installer code 4112 4112 4112 4112 *21 Quick arm enable 1 1 1 1 *22 Keypad backlight timeout 0 0 0 0 *23 Forced bypass 0 0 0

More information

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. S Y S T E M U S E R G U I D E SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

TABLE OF CONTENTS. Service Access and Commands... 78

TABLE OF CONTENTS. Service Access and Commands... 78 TABLE OF CONTENTS SECTION1-1.1 A Guided Tour - System Overview... 2 A Glance At Features... 2 The Intelligent Connection... 2 The Wireless Universe... 3 The Concept of Groups... 4 Self Test Features...

More information

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 630 SIX CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 REAR PANEL CONNECTORS...

More information

SECTION DIGITAL LIGHTING CONTROLS

SECTION DIGITAL LIGHTING CONTROLS SECTION 26 09 25 PART 1 - GENERAL 1.1 SUMMARY A. Work included: 1. General Performance 2. Digital Wall or Ceiling Mounted Occupancy Sensor System 3. Digital Wall Switches 4. Handheld Remote Controls 5.

More information

White Adjustable LinkUp LED Controller (Wifi Compatible) Part No. linkup-white-adj

White Adjustable LinkUp LED Controller (Wifi Compatible) Part No. linkup-white-adj 11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com White Adjustable LinkUp LED Controller (Wifi Compatible) Part No. linkup-white-adj The White

More information

Converging Systems Inc.

Converging Systems Inc. Converging Systems Inc. e-node Lutron e-node Interfacing with Lutron Guide Version 1.01 Revision History Date Version Description Author 10/01/2012 1.0 Consolidated Version AD 10/10/2012 1.01 Enhancements

More information

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad 1. Introduction The, P/N AU7394-xx (see Figure 1), is an integral part of the lyriq Multi-Room Audio System. It is a component which, when combined with other essential components (a Source Input Unit,

More information

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads... HWZRU;;( Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... Programming the LED Keypads... Programming the NX-E...9 Types of

More information

QUICK START. Installation & Programming Guide

QUICK START. Installation & Programming Guide QUICK START Installation & Programming Guide PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION - RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker

More information

Hybrid Security & Automation Platform

Hybrid Security & Automation Platform Hybrid Security & Automation Platform MARKETS: BUILDER MARKET Today s new home buyers are looking for technology in their homes now more than ever. Vario is designed to offer modern security allowing homes

More information

Pocket Programmer Model UPP. UPB Pocket Programmer User Guide

Pocket Programmer Model UPP. UPB Pocket Programmer User Guide UPB Pocket Programmer User Guide DESCRIPTION The Pocket Programmer (model UPP) provides many of the features of UPStart UPB configuration software in a portable hand held device. The Pocket Programmer

More information

Home Automation, Inc. Model 32A00-1. OmniTouch Touchscreen

Home Automation, Inc. Model 32A00-1. OmniTouch Touchscreen Home Automation, Inc. Model 32A00-1 OmniTouch Touchscreen Installation Manual Document Number 32I00-1 Rev A July, 2003 FCC NOTICE This device complies with FCC Rules Part 15. Operation is subject to the

More information

Interactive GSM-control GSM-RELAY PROBYTE OY

Interactive GSM-control GSM-RELAY PROBYTE OY Interactive GSM-control GSM-RELAY PROBYTE OY General PROBYTE GSM-control is a real time and interactive GSM-control- and measuring device, which allows user remotely control all the electrical appliances

More information

D1265. Installation Guide. Touchscreen Keypad

D1265. Installation Guide. Touchscreen Keypad D1265 EN Installation Guide Touchscreen Keypad D1265 Installation Guide 1.0 Introduction Contents 1.0 Introduction...3 1.1 Overview...3 1.2 Graphical Buttons...3 1.3 Audible Tones...4 1.4 Supervision...4

More information

IntesisBox KNX - AIRZONE

IntesisBox KNX - AIRZONE IntesisBox KNX - AIRZONE Gateway for the integration of Airzone InnoBUS into KNX systems. Full integration of Airzone InnoBUS air conditioning with KNX control systems. CS CS KNX EIB Bus IntesisBox RS485

More information

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7 AVA-88 WELCOME Congratulations on purchasing the AVA-88. The AVA-88 integrates multiple complicated control, automation and internet protocols into one simple plug-and-play device. It is a central controller

More information

PROGRAMMING AND INSTALLATION MANUAL

PROGRAMMING AND INSTALLATION MANUAL PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-S (software version 3.10) CA-10 plus GDAŃSK ca10plci_s_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

Keypad LCD-L (software version 3.10) CA-10 plus

Keypad LCD-L (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-L (software version 3.10) CA-10 plus GDAŃSK ca10plci_l_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.

More information

ELK-C1M1 Information Addendum

ELK-C1M1 Information Addendum ELK-C1M1 Information Addendum In addition to its super fast, dual path, alarm communications capability, the C1M1 also boasts support of Elk-RP remote programming of the M1 Control by the Alarm Company,

More information

Integrating and configuring Dynalite lighting and heating systems with SystemNet software

Integrating and configuring Dynalite lighting and heating systems with SystemNet software Integrating and configuring Dynalite lighting and heating systems with SystemNet software System Net Configuration Software 10.0 or higher Firmware 10.0 or higher S6 or six port hub only, colour touch

More information

UCM/KNX2 - Comfort to KNX Interface

UCM/KNX2 - Comfort to KNX Interface SECTION INTRODUCTION UCM/KNX2 The Comfort system can be interfaced to the KNX Bus products manufactured by members of the KNX Association. The UCM/KNX2 is a 3rd generation interface between Comfort and

More information

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup I-NXV-IM Rev F Dec 00 NetworX Series NX-V Control Panel Installation and Setup Copyright Disclaimer Trademarks and patents Copyright 00, GE Security Inc. All rights reserved. This document may not be copied

More information

NETWORK SETUP. 1. From the IP-Modules Home page Click Login

NETWORK SETUP. 1. From the IP-Modules Home page Click Login R4816-IP MODULE FOR RUNNER 1. Connect the IP-Module to your Computers LAN port with the supplied Patch cable. 2. Connect power to the IP-Module, this can come from the Alarm Panel or even a 12V battery.

More information

Clipsal HomeMinder Home Automation System

Clipsal HomeMinder Home Automation System Clipsal HomeMinder Home Automation System Part A Release 1.0.0 4 June 2000 Copyright 2000 Clipsal Integrated Systems Preface Congratulations on your purchase of HomeMinder. You now own a powerful and

More information

Table of Contents. Hardware Installation...7 Push Button Security...8. Using the Setup Wizard...9

Table of Contents. Hardware Installation...7 Push Button Security...8. Using the Setup Wizard...9 Table of Contents Table of Contents Product Overview...3 Package Contents...3 System Requirements... 3 Introduction...4 Features... 4 Hardware Overview...5 LEDs...5 Connection... 6 Hardware Installation...7

More information

1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX

1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX KNX INTEGRATION MODULE INT-KNX int-knx_en 09/11 The INT-KNX module integrates the INTEGRA alarm system with the KNX system, so the control panel can control the actuators connected to the KNX bus, and

More information

IP-Based Educational Communications Solutions

IP-Based Educational Communications Solutions IP-Based Educational Communications Solutions IP-Based Educational Communications Solutions Effective Communications Facility-Wide and District-Wide Leverage your network and lower your system costs Scalable,

More information

RGB LinkUp LED Controller (Wifi Compatible) Part No. linkup-rgb

RGB LinkUp LED Controller (Wifi Compatible) Part No. linkup-rgb 11235 West Bernardo Court, Suite 102 San Diego, CA 92127 888-880-1880 Fax: 707-281-0567 EnvironmentalLights.com RGB LinkUp LED Controller (Wifi Compatible) Part No. linkup-rgb The RGB LinkUp LED Controller

More information

TVLink RS868 ETHERNET INTERFACE

TVLink RS868 ETHERNET INTERFACE TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation

More information

Wireless module setup guide

Wireless module setup guide Wireless module setup guide 1 What you need to get started 2 Create a new Rasoft Pro Project File 2.1 Project name and House numbers 2.2 Save Locations 2.3 Adding rooms 2.4 Adding channels 2.5 Adding devices

More information

Keypad LCD (software version 3.10) CA-10 plus

Keypad LCD (software version 3.10) CA-10 plus PROGRAMMING AND INSTALLATION MANUAL Keypad LCD (software version 3.10) CA-10 plus GDAŃSK ca10plci_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only. Because

More information

Installation and Setup Instructions

Installation and Setup Instructions Installation and Setup Instructions 02-14-2008 1 Observatory Automation System Thank you for purchasing the System. This very flexible and robust system is a must-have tool for anyone wishing to secure,

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

Series. NX-8-EUR Control Panel. Installation manual

Series. NX-8-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-8-EUR Control Panel Installation manual NX-8-EUR Installation manual Page 2 23/12/04 CONTENTS CONTENTS...3 GENERAL INFORMATION...5 ORDERING INFORMATION...5 FEATURE DEFINITIONS...6

More information

Version /20/2012. User Manual. PowerLine AV 500 Network Starter Kit DHP 501AV

Version /20/2012. User Manual. PowerLine AV 500 Network Starter Kit DHP 501AV Version 1.10 09/20/2012 User Manual PowerLine AV 500 Network Starter Kit DHP 501AV Table of Contents Table of Contents Product Overview...3 Package Contents... 3 System Requirements... 3 Introduction...

More information

User s Guide. Digital Whole Home Audio Distribution System. Includes 8 audio source inputs and 8 amplified audio zones

User s Guide. Digital Whole Home Audio Distribution System. Includes 8 audio source inputs and 8 amplified audio zones User s Guide Digital Whole Home Audio Distribution System FEATURES Includes 8 audio source inputs and 8 amplified audio zones Hi-Fi2 SYSTEM Optional Hi-Fi2 Expansion Kit adds 8 more zones (16 total) Super

More information

ELK-M1XSP Serial Port Expander

ELK-M1XSP Serial Port Expander -M1XSP Serial Port Expander Supplementary Instructions & Release Notes for Firmware Version 30.X.X This version provides M1 Integration to: JetStream ing Table of Contents M1XSP Installation and Setup...

More information

Ademco Vista-20SE/First Alert FA-162C Program Sheet

Ademco Vista-20SE/First Alert FA-162C Program Sheet Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit

More information

Total Connect 2.0 Online Help

Total Connect 2.0 Online Help Security Events Users Locations Video Hints for use. After logging in hit F11 to toggle full screen mode. Hover over icons for tool tip help. Upon the initial login, control panel data should be imported

More information

Create Your Own UPB Network

Create Your Own UPB Network Create Your Own UPB Network Using UPStart & Your PEP Kit PEP Kit Supplement (KPE-06) Table of Contents Download UPStart...4 Connecting the Computer Interface Module...5 Getting Started with UPStart...6

More information

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad

INSTRUCTION/INSTALLATION SHEET lyriq Standard Keypad 1. Introduction The, P/N AU7394-xx (see Figure 1), is an integral part of the lyriq Multi-Room Audio System. It is a component which, when combined with other essential components (a Source Input Unit,

More information

Advanced DMX for Control4 version (1902)

Advanced DMX for Control4 version (1902) Advanced DMX for Control4 version 2.2.1 (1902) Quick Start Guide 1 Connect the RS 232 DMX Engine to your Control4 Controller using a DB9 straight serial cable with NO PIN4 (try not use homemade cable).

More information

CAMit I Camera with built in Modem

CAMit I Camera with built in Modem CAMit I Camera with built in Modem User s Manual CAMit I AP revision: 3.3 CAMit I Setup revision: 2.0.1 Manual revision: 2.0 Date: February 27, 2002 Congratulations You just acquired a fine product from

More information

Product Manual SZ2141

Product Manual SZ2141 Product Manual SZ11 Refrigeration Controller Communicating Controls Description The SZ11 is a microprocessor-based refrigeration controller and alarm interface designed to control three coolers or freezers

More information

Ctdigi.com. Instruction manual. Production by S & W Technology Labs

Ctdigi.com. Instruction manual. Production by S & W Technology Labs Ctdigi.com Instruction manual Production by S & W Technology Labs I. Install app II. Guard camera Guard camera Introduction Accessory Sensor Scenario Guard 360 Introduction - Catalog - Install app Scenario

More information

Installation Pre-wire Guide.

Installation Pre-wire Guide. Installation Guide www.cortexatechnology.com Copyright Cortexa Technology Inc., @ 2006 Table of Contents 2 Overview 3 System Components 4 Cortexa 7202 Home Controller 4 4 In Wall Touch Panel 4 4 Pre-wiring

More information

Created by Neevia docuprinter LT trial version

Created by Neevia docuprinter LT trial version Quick Start Guide to Using Upstart By Web Mountain Technologies When UPB modules are shipped, right out of the box, some devices will work together. For example, all wall switches are programmed to respond

More information