NWL Pacific Inc PARTS CATALOG

Size: px
Start display at page:

Download "NWL Pacific Inc PARTS CATALOG"

Transcription

1 NWL Pacific Inc PARTS CATALOG July 12, 2007

2 CODE LIST No. ITEM CODE TR CONTROL PANEL - NWL STANDARD NP-ST-V Z-PURGE NP-ZP-V01 - TR+MCC NP-MC-V01 - AUTO & MANUAL NP-AM-V01 2 BACKPLANE - 6 SLOT SLOT A 3 4 CPM CARD DCSi NP DCSi-Lite-12E - DCSi-Lite-24E - DCSi-Lite-36E - DCSi-Pro-12E - DCSi-Pro-12E - DCSi-Pro-12E - DCSi-GRC-1E - DCSi-GRC-2E 5 DIVIDER - 55kV 80MΩ P kV 120MΩ P EXTERNAL KEY INTERLOCK NP-EX-KEY 7 GFC G GVC G GRC G20828 CHOKE 10 - Up to 500mA CK500 - Up to 1500mA CK Up to 2500mA CK2500 HV BUSHING - 60kV, TOP HV-T-60-60kV, SIDE HV-S kV, TOP HV-T-75-75kV, SIDE HV-S kV, TOP HV-T kV, SIDE HV-S INTERNAL KRY INTERLOCK NP-IN-KEY 13 KEY EXCHANG BOX NP-KEY-BOX LV BUSHING 600V, 200A LV V, 300A LV V, 500A LV V, 630A LV MIGI RAPPER NP-MG OIL LEVEL INDICATOR T POWER OPTIMIZER G PRESSURE SWITCH NP-P S-CPU D S-RAP D TEMPERATURE INDICATOR WJ THERMOSTAT VK4254 RAPPER CONTROL PANEL 23 - FRONT NP-ST-R01 - FRONT & REAR NP-FR-R01 - WIDE NP-WD-R01 S.C.R Assembly - SKKT 92 / 16E NP-SCR SKKT 162 / 16E NP-SCR-02 - SKKT 330 / 16E NP-SCR-03 - SKKT 570 / 16E NP-SCR-04

3 TR CONTROL PANEL THICKNESS OF MATERIAL LOCATION COLOR OF PAINT CONTROLLER MAKER : NWL PACIFIC SS400 STS304 FRONT DOOR 3.2T 2.0T BODY 2.3T 2.0T BASE PLATE 3.2T 3.0T OTHERS 2.3T 2.0T INDOOR or OUT DOOR CUSTOMER STANDARD GRAPHIC VOLTAGE CONTROLLER NWL PACIFIC STANDARD {700(W) x 500(D) x 2350(H)} CODE: NP-ST-V01 Z-PURGE TYPE CODE: NP-ZP-V01

4 TR CONTRL + MCC CONTROL TYPE CODE: NP-MC-V01 AUTO & MANUAL SELECTOR TYPE CODE: NP-AM-V01

5 Backplane Slot Size Slot6, Slot11 Environment: 0 to 70 C, 5 to 95% non-condensing. 6SLOT CODE SLOT CODE A

6 CPM CARD CODE NP-1457 TB40 : ma TB60 : kv kv : 0~50kΩ ma : 0~50Ω MAKER : NWL PACIFIC

7 Distributed Control System Interface (DCSi) CODE : REFER TO NOTE PROCESSOR Intel 80C31, 11MHz clock NET WORK PORTS 1RS485, 2RS232 MEMORY 64K x 8EPROM, 32K x 8SRAM WATCHDOG TIMER 1.6sec Reset Timer IN 115VAC ± 5% 100mA OUT 5VDC ± 5% 1A ENVIRONMENT 0 to 70, 5 to 95% Non-Condensing PROTOCOL Modbus RTU & ASCII SIZE 215(w) x 250(D) x 44(H)(mm)

8 NOTE: DCSi-Lite-12E DCSi-Lite-24E DCSi-Lite-36E DCSi-Pro-12E DCSi-Pro-24E DCSi-Pro-36E DCSi-GRC-1E DCSi-GRC-2E REV_3: Feb28_07

9 DIVIDER CODE: P SCOPE 55KV 80MΩ RESISTOR 5MΩ 2W 1% MAKER NWL PACIFIC DIVIDER CODE: P SCOPE 72KV 120MΩ RESISTOR 5MΩ 2W 1% MAKER NWL PACIFIC

10 EXTERNAL KEY INTERLOCK TYPE MANUAL TYPE METHOD ESP T/R + ESP Simultaneously MAKER 서울안전키 CODE: NP-EX-KEY

11 Gate Firing Circuit CODE G70050 Model No. : G70050 Model Item : GFC Model Spec. : Gate Firing Circuit Maker : NWL USA

12 Graphic Voltage Controller CODE G x 128 pixel transflective liquid crystal display (LCD) Temperature compensating circuitry for contrast control White LED backlight 9 function keypad ST upsd3354d microprocessor, 40.0 MHz oscillator 288K x 8 Flash Memory 32K x 8 SRAM (2) UART s (1-RS485, 1-RS232) Isolated RS485 communications circuit Multi-Layer PCB Environment: 0 to 70 C, 5 to 95% non-condensing MAKER : NWL USA Power Requirements +5VDC ±5% at 250mA each

13 Hand-Held Programmer (GRC Keypad Display Module) CODE G x 128 pixel transflective liquid crystal display (LCD) Temperature compensating circuitry for contrast control White LED backlight 9 function keypad ST upsd3354d microprocessor, 40.0 MHz oscillator 288K x 8 Flash Memory 32K x 8 SRAM (2) UART s (1-RS485, 1-RS232) Isolated RS485 communications circuit Multi-Layer PCB Environment: 0 to 70 C, 5 to 95% non-condensing MAKER : NWL USA Power Requirements +5VDC ±5% at 250mA each

14 HIGH FREQUENCY CHOKE (Air Core Reactor) Up to 500mA CODE: CK500 Model Spec. Up to 1500mA CODE: CK1500 Up to 2500mA CODE: CK2500 MAKER NWL PACIFIC

15 HIGH VOLTAGE BUSHING 60KV (TOP & SIDE) RATING VOLTAGE 75KV (TOP & SIDE) 100KV (TOP & SIDE) MAKER WARCO INC USA TOP CODE: HV-T-60, SIDE CODE; HV-S-60 TOP CODE: HV-T-75, SIDE CODE; HV-S-75 TOP CODE: HV-T-100, SIDE CODE; HV-S-100

16 INTERNAL KEY INTERLOCK CODE: NP-IN-KEY METHOD 1. Continuous Switch EARTH T/R + ESP SIMULTANEOUSLY 2. Isolation Switch DISCONNECTS ESP, EARTH ESP MAKER NWLPACIFIC

17 KEY EXCHANGE BOX MAKER 서울안전키 CODE: NP-KEY-BOX

18 LOW VOLTAGE BUSHING RATING VOLTAGE 600V 200A 300A RATING CURRENT 500A 630A MAKER DONG JIN CODE: LV-200 CODE: LV-300 CODE: LV-500 CODE: LV-630

19 MIGI RAPPER MATERIAL : - RAPPER COIL TANK : MILD STEEL - RAPPER COIL PIPE : POLYESTER GLASS - TERMINAL BOX : CAST IRON CODE: NP-MG-01 RESISTANCE INDUCTANCE WEIGHT MAKER 2.5~2.8 Ohm 30~35 mh 30 kg NWL PACIFIC

20 OIL LEVEL INDICATOR MODEL NO. T0201 MATERIAL ALUMINUM MOUNTING TYPE BOLT MAKER TAI JIN CODE: T0201

21 Power Optimizer CODE G20808 Microprocessor I/O Board (D2157D) Process Board (D2800G) Power Board (D20136) INPUT : AC 120V Local & Network Port Built in Maker : NWL USA

22 Power Supply CODE D20655 Power Supply is manufactured by POWER-ONE company located in Camarillo, CA. It belongs to MAP110 series switching Power Supplies. Maker : NWL USA Power Supply parameters Input: 100V 250VAC 3.3A 47-63Hz Outputs: +5 VDC at 12A continuous operation; 20A peak + 15 VDC at 5A continuous operation; 7.3A peak -15 VDC at 1A continuous operation; 1.5A peak + 24 VDC at 3A continuous; 4A peak Environment: 0 to 70 C, 5 to 95% non-condensing

23 PRESSURE SAFETY DEVICE CODE T0501 MODEL NO. T0501 USE CONDITION OUTDOOR OPERATION PRESSURE 0.7%%P0.07 Kgf/Cm ACCURACY ±10% MAKER TAI JIN INDUSTRIES CO.

24 RECTIFIER SCOPE 55KV 500mA 72KV 500mA DIODE VMI RX 100SG 0016 MAKER NWL PACIFIC CODE: NP-RF-01 CODE: NP-RF-02 RECTIFIER SCOPE 55KV 501mA to 1500mA 55KV 1501ma to 2500mA SCOPE 72KV 501mA to 1500mA 72kv 1501mA to 2500mA DIODE(55KV) CS461S45 DIODE(72KV) VMI Z503G 9940 MAKER NWL PACIFIC CODE: NP-RF-03 CODE: NP-RF-04 CODE: NP-RF-05 CODE: NP-RF-06

25 PRESSURE SWITCH CODE: NP-P-01 MODEL TYPE 14 RANGE 0.15 ~ 1 BAR SET POINT 0.5 BAR MAKER : BAILEY & MACKEY LTD. (UK)

26 Smart CPU CODE D P80CE558 microprocessor, MHz Crystal 128K x 8 Flash Memory 32K x 8 non-volatile SRAM with Timekeeper 32K x 8 non-volatile SRAM Watchdog circuitry UART Isolated RS485 communications circuit I 2 C communications circuit Multi-Layer PCB (+5VDC, ± 15 VDC, Ground) Environment: 0 to 70 C, 5 to 95% non-condensing Maker : NWL USA Power requirements +5VDC ±5% at 130mA each +15VDC ±5% at 37mA each -15VDC ±5% at 11mA each

27 Smart-Rap CODE D P80CE558 microprocessor, MHz Crystal 128K x 8 Flash Memory 32K x 8 non-volatile SRAM Watchdog circuitry UART Isolated RS485 communications circuit I 2 C communications circuit (16) 25 AMP triacs with associated circuitry (2) 25 AMP SCRs with associated circuitry Indicating LED s for each output Multi-Layer PCB (+5VDC, ± 15 VDC, +24VDC, Ground) Environment: 0 to 70 C, 5 to 95% non-condensing Maker : NWL USA Power requirements +5VDC ±5% at 300mA each +15VDC ±5% at 6mA each -15VDC ±5% at 1mA each +24VDC ±5% at 120mA each

28 TEMPERATURE INDICATOR CODE WJ-80 MODEL NO. WJ-80 MATERIAL STAINLESS STEEL PARAMETER 0 ~120 MAKER WOOJIN (WISE)

29 THERMOSTAT MODEL VK4254 RANGE 0 C ~ 110 C SET POINT 95 C (TRIP) MAKER SUNVIC INK. (UK) CODE VK4254

30 RAPPER CONTROL PANEL SS400 STS304 FRONT DOOR 3.2T 2.0T THICKNESS OF MATERIAL BODY 2.3T 2.0T BASE PLATE 3.2T 3.0T OTHERS 2.3T 2.0T LOCATION IN or OUT DOOR COLOR OF PAINT CUSTOMER STANDARD CONTROLLER GRAPHIC RAPPER CONTROLLER MAKER : NWL PACIFIC NWL PACIFIC STANDARD {700(W) x 500(D) x 2350(H)} FRONT TYPE CODE: NP-ST-R01 FRONT REAR FRONT & REAR TYPE CODE: NP-FR-R01 WIDE TYPE CODE: NP-WD-R01

31 S.C.R Assembly V RMS : 1700V, V RRM, V DRM: 1600V SKKT 92 / 16E NP SCR 01 I TRMS : 150A I TAV : 95A SKKT 162 / 16E NP SCR 02 I TRMS : 250A I TAV : 160A SKKT 330 / 16E NP SCR 03 I TRMS : 510A I TAV : 330A SKKT 570 / 16E NP SCR 04 I TRMS : 1000A I TAV : 570A MAKER SEMIKRON

Graphic Rapper Controller (GRC) User s Guide

Graphic Rapper Controller (GRC) User s Guide Graphic Rapper Controller (GRC) User s Guide Rev. 2.1 Revisions Rev. Date Author Description 1.0 11/2/99 Original 1.1 8/10/05 Added multiple rap feature 2.0 1/13/06 FGS Updated for new display screens

More information

Surge Current Generators PG **-****

Surge Current Generators PG **-**** Surge Current Generators PG **-**** Waveform 8/20 µs Surge current: 40 ka - 100 ka The surge current generators PG **-*** generate standard impulse currents with waveform 8/20 µs according to IEC, EN,

More information

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000 Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via

More information

DCSi-III: ESP Power Optimizer, Power Plus Optimizer, Power Plus DSP, Chopper Optimizer

DCSi-III: ESP Power Optimizer, Power Plus Optimizer, Power Plus DSP, Chopper Optimizer DCSi-III: ESP Power Optimizer, Power Plus Optimizer, Power Plus, Chopper Optimizer Users Guide Revision: 1.6 Date: 3/22/2013 DCSi Gen III V1_6.doc 05/03/13 1 Revisions Rev. Date Author Description 1.0

More information

Testing Instruments Manufactured by

Testing Instruments Manufactured by Circuit Breaker Dynamic Contact Resistance Meter HISAC Ultima Circuit Breaker Dynamic Test Set with up to Six Channel Dynamic Contact Resistance Meter 24 Binary Channels (4 Main + 4 PIR per Pole, 3 Poles

More information

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIA Series Fully-Automated Multi-Function Electrical Safety Compliance Analyzers U.S. Patent Nos. (6,054,865, 6,011,398,

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

Dielectric Withstand and Ground Bond Testers

Dielectric Withstand and Ground Bond Testers Dielectric Withstand and Ground Bond Testers For Safety Agency Production Line Compliance Testing U.S. patent#: 5,548,501, 6,054,865. Other patents pending. Safety agency listed. ENHANCED GRAPHIC LCD The

More information

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation LineGuard 2300 The LineGuard 2300 Electronic linebreak detection system monitors natural gas pipeline pressure and rate of pressure drop, and can provide manual or automatic control of a single valve actuator

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending) Hypot III DIELECTRIC WITHSTAND TESTERS For Production Line Safety Agency Compliance Testing Graphic Liquid Crystal Display 10 Memories with 3 Steps per Memory Low Limit Detection System 3605 AC Hipot SmartGFI

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

SM100. On-Line Switchgear Condition Monitoring

SM100. On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of

More information

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG CATALOG INTRODUCTION The temperature monitor MASTERTEMP was developed to monitor oil and winding temperatures in transformers and reactors immersed in oil. It features also the activation of cooling fans

More information

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

Control Panel CP600 CP635-FB, CP635-FW

Control Panel CP600 CP635-FB, CP635-FW DATA SHEET Control Panel CP600 CP635-FB, CP635-FW 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535110R6001 CP635-FB, control panel, TFT graphical display, single-touch projected Active

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

Line Impedance Stabilization Network (LISN)

Line Impedance Stabilization Network (LISN) Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

CROSSFIRE Ultra-Low Power Chemical Injection Pump

CROSSFIRE Ultra-Low Power Chemical Injection Pump CROSSFIRE Ultra-Low Power Chemical Injection Pump Introduction The LCO Technologies CROSSFIRE Chemical Injection pump is an ultra-low power device that is designed to reduce chemical costs, maintenance

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

CAN-Transceiver Data Register Map MODBUS Slave RTU

CAN-Transceiver Data Register Map MODBUS Slave RTU MODBUS Slave RTU V1.40 Table of Contents INTRODUCTION... 3 CAN TRANSCEIVER GLOBAL DATA... 3 OPTIONAL DIGITAL INPUTS... 3 AVC (TR CONTROL) REGISTER BASE ADDRESSES... 3 AVC MODBUS REGISTER DEFINITION...

More information

PD ProtEX-MAX Strain Gauge, Load Cell & mv Meter. Strain gauge. IECEx MAX

PD ProtEX-MAX Strain Gauge, Load Cell & mv Meter.   Strain gauge. IECEx MAX PD8-6100 ProtEX-MAX Strain Gauge, Load Cell & mv Meter TM MAX IECEx Strain gauge Modern, Sleek and Practical Enclosure Display Mountable at 0, 90, 180, & 270 Degrees Explosion-Proof, IP68, NEMA 4X Enclosure

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

BXD17 Series. Features. Analytical instrumentation for your measurement applications. BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile

More information

ES-362U PRESETTABLE MASTER TIMER

ES-362U PRESETTABLE MASTER TIMER 142 SIERRA ST., EL SEGUNDO, CA 90245 USA (310)322-2136 FAX (310)322-8127 www.ese-web.com ES-362U PRESETTABLE MASTER TIMER OPERATION AND MAINTENANCE MANUAL The ES-362U is a four digit, presettable 100 minute

More information

EMS467 Monitoring System. Installation and Operations Manual Section 40

EMS467 Monitoring System. Installation and Operations Manual Section 40 EMS467 Monitoring System Installation and Operations Manual 00-02-0672 01-26-10 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

In-Sight I/O. In-Sight expansion module (For use with in-sight 5000 series vision sensors and Id readers, and 3400 vision sensors)

In-Sight I/O. In-Sight expansion module (For use with in-sight 5000 series vision sensors and Id readers, and 3400 vision sensors) System DISTRIBUTEUR C ONSEIL DEPUIS 1 9 8 5 In-Sight i/o specifications In-Sight BREakout module (For use with in-sight 5000 series vision sensors and id readers) Note: All measurements are provided in

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive Type number key VFD 007 L 21 A Version number A= filter, NPN inputs B=Built-in filter, NPN inputs D= filter, PNP inputs E=Built-in filter, PNP inputs Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ VFD-L

More information

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31 MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31 PPS PART NO. 133550 DRAWING NO. 133550-10 THIS MANUAL ASSIGNED TO THE S/N: THE INFORMATION CONTAINED IN THIS MANUAL IS PROPRIETARY TO PACIFIC POWER SOURCE,

More information

Specification Sheet For electronically commutated motors

Specification Sheet For electronically commutated motors SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes

More information

ARP-3700AP-E01 Series

ARP-3700AP-E01 Series 21.5" 19" 17" 15" 10.4" ARP-3700AP-E01 Series Flush Bezel Resistive Touch Panel Computers SMART BATTERY Specifications ARP-3710AP-E01 ARP-3715AP-E01 ARP-3717AP-E01 LCD Display Display Size (Diagnol) 10.4

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

Series Watt DC Power Supplies

Series Watt DC Power Supplies Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains

More information

PRA Inc th Place NE Arlington, WA U.S.A.

PRA Inc th Place NE Arlington, WA U.S.A. 2360 Series Quartz Crystal - Oscillator Aging and Aging Measurement Test System Devices are operating while aging Frequency Measurement made while aging Up to 4000 devices simultaneously in a Model 2360

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

Jinyoung Contech Co., Ltd.

Jinyoung Contech Co., Ltd. To: Jinyoung Contech Co., Ltd. #501, 222-12 MARIOTOWER, GURO3-DONG, GURO-KU, SEOUL, KOREA TEL : 82-2-890-6400 FAX : 82-2-890-6406 HOME PAGE : http://www.jyct.com/ Issued Date : Oct 26, 2003 Page : 8pages

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point January 2010 PACSystems RX3i and Series 90-30 IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TB IC694MDL916 Q1 Q2 Q3 Q4 Q5 Q6 Q7

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

NETRONICS HS3500 CONTROLLER

NETRONICS HS3500 CONTROLLER NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES

Series MV2000 MEDIUM VOLTAGE HIGH CURRENT POWER SUPPLIES FEATURES 2kW output power Output voltages from 20V to 300V High Packing Density - 2kW in 1U Parallel/series operation Stackable, cooling is front to rear Active Power Factor Correction Custom options available

More information

PGR-2601 MANUAL DC GROUND-FAULT RELAY

PGR-2601 MANUAL DC GROUND-FAULT RELAY POWR-GARD Ungrounded DC System PGR-2601 SERIES DC Ground-Fault Relay PGR-2601 MANUAL DC GROUND-FAULT RELAY AUGUST 31, 2009 REVISION 1 POWR-GARD DC GROUND-FAULT RELAY PWR TRIP 5 4 3 2 6 - BUS 8 10 15 20

More information

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 47LYV. Digital Panel Meters 47 Series Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function

More information

NF770 Temperature Compensation Liquid Flow Computer

NF770 Temperature Compensation Liquid Flow Computer NF770 Temperature Compensation Liquid Flow Computer Overview Mass Flow measurement at a comparatively low cost can be achieved using the Model NF770 Liquid Flow Computer, an RTD temperature sensor and

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

DSP240-LPI Inverter Controller Card. Technical Brief

DSP240-LPI Inverter Controller Card. Technical Brief DSP240-LPI Inverter Controller Card Technical Brief September 2006 Manual Release 3.0 Card Revision 3.0 Copyright 2001-2006 Creative Power Technologies P.O. Box 714 MULGRAVE Victoria, 3170 Tel: +61-3-9543-8802

More information

Keywords Digital IC tester, Microcontroller AT89S52

Keywords Digital IC tester, Microcontroller AT89S52 Volume 6, Issue 1, January 2016 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Digital Integrated

More information

Digital multimeters DMG

Digital multimeters DMG Digital multimeters DMG 600-610 ENERGY AND AUTOMATION POWER OF ENERGY SAVING Digital multimeters DMG 600-610 are capable of viewing the measurements with high accuracy on the wide LCD display, which allow

More information

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

PFXGP4601TAD.   Pro-face Xycom GP4000 PFXGP4601TAD PFXGP4601TAD http://www.axcontrol.com/automation/pro-face/gp-4000/pfxgp4601tad Pro-face Xycom GP4000 PFXGP4601TAD Pro-face Xycom GP-460xT GP460xT Touch Screen Operator Interface 12.1 TFT Analog Color LCD

More information

CAMAC CERN CE 600W. Main Features. Request Quote

CAMAC CERN CE 600W. Main Features. Request Quote CERN CE 600W Request Quote CERN-CE 600W WIENER offers a line of modular designed crates compliant with ESONE and CERN standards. This crates series is configured with 600W 650W linear regulated, low noise

More information

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP651, CP651-WEB DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

PD Helios Strain Gauge, Load Cell & mv Meter.  Strain gauge. Actual Size Digit PD2-6100 Helios Strain Gauge, Load Cell & mv Meter Actual Size Digit Strain gauge Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

NF760 Batch Controller

NF760 Batch Controller NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers

Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers Designed to Meet Safety Agency Standards such as UL, CSA, IEC, VDE, TÜV and the European Norms including the Low Voltage Directive

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT 1/4 to 2 NPT Features Direct mount ISO5211 Full Port 316 stainless steel ball valve 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve position indicator Rugged aluminum Type 4X weatherproof

More information

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure 689 PHOTO PHOTO Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-17 Sensor selection guide... P.661~ Related Information Glossary of terms... P.1373~ General

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Strand Lighting Specification

Strand Lighting Specification I. DIGITAL ENVIRON 90 DIMMER CABINET(S) A. GENERAL 1. The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist of 6

More information

Secrure door control and I/O expansion. Installation Guide. (ver 1.0)

Secrure door control and I/O expansion. Installation Guide. (ver 1.0) Secrure door control and I/O expansion Installation Guide (ver 1.0) www.supremainc.com Contents Product Contents 3 Front Panel Description 4 Rear Panel Description 5 Connectors for External Interfaces

More information

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

HVAC Products. Introducing the SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives HVAC Products Introducing the SED2 Variable Frequency Drives Designed Specifically for HVAC Applications From a global leader in drives technology and innovation, now comes a drive specifically configured

More information

Universal Smart Drive TYPE MR41E Patented system

Universal Smart Drive TYPE MR41E Patented system Universal Smart Drive TYPE MR41E Patented system Applications Features Reliability Electronic technology Communication Modularity Energy saving The MR41E electrical operating mechanism is robustly designed

More information

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB DATA SHEET Control Panel CP600 CP635, CP635-B, CP635-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535100R0001 CP635, control panel, TFT graphical display, single-touch screen,

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

BACnet Controller for General-purpose Building Applications

BACnet Controller for General-purpose Building Applications Specifications BACnet Controller for General-purpose Building Applications General Model WJ-1101 is the BACnet controller to be used for a wide range of building applications such as air-conditioning and

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

PKS-FD432S-13 - Servo System

PKS-FD432S-13 - Servo System PKS-FD432S-13 - Servo System FEATURES 176-253VAC of 6 Nm Power Ratings up to 1260 Watts 2,500 PPR Incremental Encoder Maximum Speed of 2850 RPM IP65 for Body, IP54 Shaft Seal Brake Option Available Position,

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

PFXGP4503TAD.   Pro-face Xycom GP4000 PFXGP4503TAD PFXGP4503TAD http://www.axcontrol.com/automation/pro-face/gp-4000/pfxgp4503tad Pro-face Xycom GP4000 PFXGP4503TAD Pro-face Xycom GP-450xT GP450xT Touch Screen Operator Interface 10.4 TFT Analog Color LCD

More information

DSP Graphic Voltage Controller (GVC) User s Guide

DSP Graphic Voltage Controller (GVC) User s Guide DSP Graphic Voltage Controller (GVC) User s Guide Dwg. A132249 Revisions Rev. Date Author Description 0 11/19/10 FGS Original A 1/20/12 FGS Included SD card, Rapper Board changes B 12/28/12 FGS Updated

More information

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95 Part 1 - GENERAL ASEA BROWN BOVERI ABB Industrial Systems Inc. Standard Drives ACH500-06E Effective 6/1/95 Sample Specification for Adjustable Frequency Drives (2 to 400 HP) for Variable Torque Applications

More information

DSP Graphic Voltage Controller (GVC) Retrofit Installation and Startup Guide

DSP Graphic Voltage Controller (GVC) Retrofit Installation and Startup Guide DSP Graphic Voltage Controller (GVC) Retrofit Installation and Startup Guide Dwg. Revisions Rev. Date Author Description 0 9/9/10 F.Skovran Initial A 11/12/10 F.Skovran Corrected General Wiring Diagram

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information