AIX Host Utilities 6.0 Release Notes

Size: px
Start display at page:

Download "AIX Host Utilities 6.0 Release Notes"

Transcription

1 IBM System Storage N series AIX Host Utilities 6.0 Release Notes GC

2

3 Contents AIX Host Utilities 6.0 Release Notes The 6.0 release of the AIX Host Utilities Information on finding system requirements New features in the 6.0 release of the AIX Host Utilities Updates to the Release Notes Known problems and limitations Cannot modify LUN queue depth using SMIT Problem with performance of large files on JFS (MPIO) After failover, MPIO defines failed paths as missing Where to find additional information Websites Copyright and trademark information Trademark information Notices Copyright IBM Corp iii

4 iv IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

5 AIX Host Utilities 6.0 Release Notes These Release Notes contain the latest information for the AIX Host Utilities 6.0, including updates about known problems, limitations, and information on tunable parameters. The Release Notes also include any issues that may have been discovered after the Host Utilities were released. These Release Notes are updated when new information on using the AIX Host Utilities become available. It is a good practice to periodically check the Release Notes to see if new information has been added. See the Updates to the Release Notes on page 2 section to determine whether information has been added since you last checked. The 6.0 release of the AIX Host Utilities The AIX Host Utilities enable you to connect an AIX host to IBM N series storage systems. The AIX Host Utilities support multiple environments and both the FC and FCoE protocols. The supported environments are AIX MPIO (Native OS) and PowerVM. Note: For specific information about the operating system versions and updates that the Host Utilities support, see the IBM N series interoperability matrix, which is accessed and navigated as described in Websites. Note: For more information about PowerVM feature, see the Red Book available at The Host Utilities software is packaged as a single, compressed file. You can download the compressed file and the documentation from the IBM N series website, which is accessed and navigated as described in Websites. The AIX Host Utilities 6.0 Installation and Setup Guide provides instructions for installing and setting up the Host Utilities to work with your environment and protocol. The compressed file contains the following Host Utilities software packages: v SAN_Tool_Kit This directory contains the SAN Toolkit software package Ontap.SAN_toolkit, which applies to all AIX Host Utilities environments and works with all multipathing solutions. Copyright IBM Corp

6 v The host settings software package for your multipathing solution. The host settings package is an Object Data Manager (ODM) stanza LPP package that includes the following: The AIX MPIO ODM fileset for N series LUNs The common AIX MPIO message catalog There is a host settings software package for each multipathing solution that the Host Utilities support: v MPIO This directory contains the package Ontap.MPIO_Host_Utilities_Kit for environments that use AIX MPIO for multipathing. This applies to both AIX MPIO environments and PowerVM environments. To install the AIX 6.0 Host Utilities, you need to install both the host settings software package for your environment and the SAN Toolkit software package. Information on finding system requirements IBM qualifies additional components between releases of the Host Utilities software. For the most up-to-date information on the system requirements, see the N series interoperability matrix website (accessed and navigated as described in Websites). Support for Live Partition Mobility Live Partition Mobility (LPM) is a feature of PowerVM. The AIX 5.1 Host Utilities support all SAN-related features of PowerVM. For further details on the PowerVM feature set, see the Red Book, which is available online at New features in the 6.0 release of the AIX Host Utilities There are no new features at this time of the release. Updates to the Release Notes The Release Notes are updated between product releases as new information is uncovered. October 2012 The AIX Host Utilities 6.0 Installation and Setup Guide was updated in October to make the following changes: v Information about Veritas Storage Foundation was removed 2 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

7 While Veritas Storage Foundation is no longer qualified with AIX Host Utilities 6.0, it is supported in earlier versions of the AIX Host Utilities. For more information about the versions that support Veritas, see the N series interoperability matrix website (accessed and navigated as described in Websites). v References to iscsi protocol support with AIX Host Utilities The AIX Host Utilities 6.0 do not support the iscsi protocol. Note: The AIX Host Utilities 6.0 compressed installation file does contain an installation package for a ontap.iscsi_host Utilities_Kit for single-path iscsi. Because iscsi is not supported with AIX Host Utilities 6.0, information on this package file is not included in the AIX Host Utilities 6.0 documentation. v To add information that starting with AIX Host Utilities 6.0, the pre-install script automatically clears the Single Path Reserve when it detects a SAN-booted device from an N series LUN. v To add information about the maximum number of paths for a SAN boot configuration with AIX Host Utilities 6.0. The post-install script releases the Single Path Reserve when a boot device with VID=ONTAP is detected during the installation. As a result the data LUNs have no specific path limit; however, it is recommended that maximum path limit is set to 4 for all AIX SAN boot deployments. AIX Host Utilities 6.0 Release Notes 3

8 4 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

9 Known problems and limitations Some unexpected and potentially undesired behaviors, and in some cases, workaround to avoid these behaviors, have been identified. Cannot modify LUN queue depth using SMIT You cannot modify the queue_depth attribute for Data ONTAP LUNs using SMIT. At this time, there are no SMIT screens that enable you to modify the queue_depth attribute for Data ONTAP LUN devices. Instead of using SMIT, use the chdev command to set the queue_depth attribute. For example, to set the queue_depth attribute to 64 on hdisk5, enter the following command: chdev -l hdisk5 -a queue_depth=64 Problem with performance of large files on JFS2 The performance on a large file (over 200 GB) in a JFS2 file system may decline as the file increases in size. This problem appears to be related to JFS2 and the AIX Virtual Memory Manager (VMM). Use direct I/O to bypass the VMM. Refer to the AIX 5L Performance Management Guide for more information on tuning direct I/O. (MPIO) After failover, MPIO defines failed paths as missing If your AIX host reboots when your storage cluster is in a failover state, MPIO defines the failed paths as missing instead of failed. The workaround for this issue depends on whether you have an HACMP environment. HACMP environment workaround: To get MPIO to correctly recognize the failed states when you are using HACMP, complete the following steps: 1. Wait until the storage system cluster is no longer in a failover state. Copyright IBM Corp

10 2. Create a pre-event script that forces a bus scan before bringing the resource group online. Note: If you perform these steps while the storage system cluster is in a failover state, the paths remain in a missing state. Non-HACMP environment workaround: Rescan the bus before you bring any volume groups online. 6 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

11 Where to find additional information The following table describes documents with the most current information about host and storage system requirements and additional documentation. If you want... Go to... The latest supported configurations Support information The IBM N series support website at: Configuring and managing the storage system Supported Fibre Channel SAN topologies Verifying storage systems and environments Configuring your host for the Host Utilities The following documents for your Data ONTAP release: v The Data ONTAP Software Setup Guide v The Data ONTAP SAN Administration Guide (formerly the Data ONTAP Block Access Management Guide for iscsi and FC) v The Data ONTAP Release Notes v The Data ONTAP Commands: Manual Page Reference, Volume 1 v The Data ONTAP Commands: Manual Page Reference, Volume 2 v The Data ONTAP Upgrade and Revert/Downgrade Guide for 7-Mode The Data ONTAP SAN Configuration Guide (formerly the Data ONTAP Block Access Management Guide for iscsi and FC) IBM System Storage N series Introduction and Planning Guide or the Hardware and Service Guide for your N series system. The HP-UX Host Utilities Installation and Setup Guide The Linux Host Utilities Installation and Setup Guide The AIX Host Utilities Installation and Setup Guide The Windows Host Utilities Installation and Setup Guide Copyright IBM Corp

12 8 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

13 Websites IBM maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates. The following web pages provide N series information: v A listing of currently available N series products and features can be found at the following web page: v The IBM System Storage N series support website requires users to register in order to obtain access to N series support content on the web. To understand how the N series support web content is organized and navigated, and to access the N series support website, refer to the following publicly accessible web page: This web page also provides links to AutoSupport information as well as other important N series product resources. v IBM System Storage N series products attach to a variety of servers and operating systems. To determine the latest supported attachments, go to the IBM N series interoperability matrix at the following web page: v For the latest N series hardware product documentation, including planning, installation and setup, and hardware monitoring, service and diagnostics, see the IBM N series Information Center at the following web page: Copyright IBM Corp

14 10 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

15 Copyright and trademark information This section includes copyright and trademark information, and important notices. Copyright information Copyright Network Appliance, Inc. All rights reserved. Printed in the U.S.A. Portions copyright 2012 IBM Corporation. All rights reserved. US Government Users Restricted Rights - Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. No part of this document covered by copyright may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. References in this documentation to IBM products, programs, or services do not imply that IBM intends to make these available in all countries in which IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only IBM s product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any of IBM s or NetApp s intellectual property rights may be used instead of the IBM or NetApp product, program, or service. Evaluation and verification of operation in conjunction with other products, except those expressly designated by IBM and NetApp, are the user s responsibility. No part of this document covered by copyright may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, Copyright IBM Corp

16 INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S.A. patents, foreign patents, or pending applications. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS (October 1988) and FAR (June 1987). Trademark information IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. NetApp, the NetApp logo, Network Appliance, the Network Appliance logo, Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePoint Predictor, Bycast, Campaign Express, ComplianceClock, Cryptainer, CryptoShred, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort, DenseStak, Engenio, Engenio logo, E-Stack, FAServer, FastStak, FilerView, 12 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

17 FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexSuite, FlexVol, FPolicy, GetSuccessful, gfiler, Go further, faster, Imagine Virtually Anything, Lifetime Key Management, LockVault, Manage ONTAP, MetroCluster, MultiStore, NearStore, NetCache, NOW (NetApp on the Web), Onaro, OnCommand, ONTAPI, OpenKey, PerformanceStak, RAID-DP, ReplicatorX, SANscreen, SANshare, SANtricity, SecureAdmin, SecureShare, Select, Service Builder, Shadow Tape, Simplicity, Simulate ONTAP, SnapCopy, SnapDirector, SnapDrive, SnapFilter, SnapLock, SnapManager, SnapMigrator, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapSuite, SnapValidator, SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, Tech OnTap, The evolution of storage, Topio, vfiler, VFM, Virtual File Manager, VPolicy, WAFL, Web Filer, and XBB are trademarks or registered trademarks of NetApp, Inc. in the United States, other countries, or both. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks. NetApp, Inc. NetCache is certified RealSystem compatible. Copyright and trademark information 13

18 14 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

19 Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe on any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-ibm product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, N.Y U.S.A. For additional information, visit the web at: The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make Copyright IBM Corp

20 improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-ibm web sites are provided for convenience only and do not in any manner serve as an endorsement of those web sites. The materials at those web sites are not part of the materials for this IBM product and use of those web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning non-ibm products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-ibm products. Questions on the capabilities of non-ibm products should be addressed to the suppliers of those products. If you are viewing this information in softcopy, the photographs and color illustrations may not appear. 16 IBM System Storage N series: AIX Host Utilities 6.0 Release Notes

21 Notices 17

22 NA _A0, Printed in USA GC

IBM. Single Mailbox Recovery 7.2 Release Notes. IBM System Storage N series GC

IBM. Single Mailbox Recovery 7.2 Release Notes. IBM System Storage N series GC IBM System Storage N series IBM Single Mailbox Recovery 7.2 Release Notes GC27-3911-05 Contents Product Overview... 2 New and Modified Features... 3 Single Mailbox Recovery Agents... 3 PST Source Agent...

More information

IBM. SnapManager 7.2 for Microsoft Exchange Server Release Notes. IBM System Storage N series GC

IBM. SnapManager 7.2 for Microsoft Exchange Server Release Notes. IBM System Storage N series GC IBM System Storage N series IBM SnapManager 7.2 for Microsoft Exchange Server Release Notes GC26-7883-13 Contents Product overview................................ 1 New in this release...............................

More information

SnapDrive for Windows Release Notes

SnapDrive for Windows Release Notes IBM System Storage N series SnapDrive 7.0.3 for Windows Release Notes GC26-7881-24 Contents New in this release............................ 1 Upgrade notes.............................. 1 Changed commands............................

More information

GA NA _A0. IBM System Storage N series Gateway Implementation Guide for IBM XIV Storage

GA NA _A0. IBM System Storage N series Gateway Implementation Guide for IBM XIV Storage GA32-0794-00 NA 210-04953_A0 IBM System Storage N series Gateway Implementation Guide for IBM XIV Storage Copyright and trademark information Copyright information Copyright 1994-2010 NetApp, Inc. All

More information

Replacing a Failed Drive in the EF550 Flash Array

Replacing a Failed Drive in the EF550 Flash Array Replacing a Failed Drive in the EF550 Flash Array To access this product, go to the NetApp Support Site at support.netapp.com. You can determine whether you have a failed drive in two ways: The Recovery

More information

IBM. Single Mailbox Recovery Release Notes. IBM System Storage N series GC

IBM. Single Mailbox Recovery Release Notes. IBM System Storage N series GC IBM System Storage N series IBM Single Mailbox Recovery 7.1.1 Release Notes GC27-3911-04 Contents Product Overview... 3 New and Modified Features... 4 Single Mailbox Recovery Agents... 5 PST Source Agent...

More information

Installing a Cisco Nexus 5596 cluster switch and passthrough panel in a NetApp cabinet

Installing a Cisco Nexus 5596 cluster switch and passthrough panel in a NetApp cabinet Installing a Cisco Nexus 5596 cluster switch and passthrough panel in a NetApp cabinet These instructions describe how to install the Cisco Nexus 5596 switch and pass-through panel in a NetApp cabinet.

More information

NetApp System Manager 1.1 Quick Start Guide

NetApp System Manager 1.1 Quick Start Guide NetApp System Manager 1.1 Quick Start Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 USA Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation

More information

NetApp Storage Replication Adapter for E- Series Installation and User Guide

NetApp Storage Replication Adapter for E- Series Installation and User Guide NetApp Storage Replication Adapter for E- Series Installation and User Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-08653_A0 495 East Java Drive Fax: +1 (408) 822-4501 Release date:

More information

Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray

Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray Replacing a Failed Controller Battery in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray To access this product, go to the NetApp support site at support.netapp.com. You can determine

More information

Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray

Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray Replacing a Failed Power-Fan Canister in the E5612 or the E5624 Controller-Drive Tray To access this product, go to the NetApp Support Site at mysupport.netapp.com. Before you replace the power-fan canister

More information

Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray

Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray Replacing Failed Memory in the E5512 Controller-Drive Tray or the E5524 Controller-Drive Tray The controller canister in either a E5512 controller-drive tray or a E5524 controller-drive tray has cache

More information

FlexArray Virtualization Implementation Guide for NetApp E-Series Storage

FlexArray Virtualization Implementation Guide for NetApp E-Series Storage ONTAP 9 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage June 2017 215-11151-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents Where to find information

More information

Replacing a Failed Controller Canister in the EF550 Flash Array

Replacing a Failed Controller Canister in the EF550 Flash Array Replacing a Failed Controller Canister in the EF550 Flash Array To access this product, go to the NetApp Support Site at support.netapp.com. Use this procedure to replace a controller canister in the EF550

More information

IBM. OnCommand Plug-in for Microsoft Release Notes. IBM System Storage N series GA

IBM. OnCommand Plug-in for Microsoft Release Notes. IBM System Storage N series GA IBM System Storage N series IBM OnCommand Plug-in 4.1.1 for Microsoft Release Notes GA32-1028-06 Contents Product overview............................. 1 New in this release............................

More information

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC IBM System Storage N series IBM SnapDrive 7.1.3 for Windows Release Notes GC26-7881-27 Contents New in this release............................... 1 New features in SnapDrive 7.1.3 for Windows........................

More information

Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray

Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray Replacing a Failed Controller Battery in the E5560 Controller- Drive Tray To access this product, go to the NetApp Support Site at support.netapp.com. You can determine whether you have a failed controller

More information

Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray

Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray Replacing a Failed Host Interface Card in the E5560 Controller- Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.2.4 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Replacing a Cisco Nexus 5010 cluster switch

Replacing a Cisco Nexus 5010 cluster switch Replacing a Cisco Nexus 5010 cluster switch Replacing a defective Cisco Nexus 5010 cluster switch in a cluster network is a nondisruptive procedure (NDU). Before you begin The following conditions must

More information

SnapManager for Hyper-V Release Notes

SnapManager for Hyper-V Release Notes IBM System Storage N series SnapManager 2.0.1 for Hyper-V Release Notes GC52-1352-04 Contents What SnapManager for Hyper-V is........................ 1 New in this release...............................

More information

Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray

Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray Replacing a Failed Host Interface Card in the E2712 Controller- Drive Tray or the E2724 Controller-Drive Tray NOTE Possible equipment damage Only a qualified service technician should perform this procedure,

More information

FlexArray Virtualization

FlexArray Virtualization FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.3.2 FlexArray Virtualization Implementation Guide for NetApp E-Series Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

E-Series Converting the Protocol of E2800 Host Ports (New Systems)

E-Series Converting the Protocol of E2800 Host Ports (New Systems) E-Series Converting the Protocol of E2800 Host Ports (New Systems) October 2016 215-11500_A0 doccomments@netapp.com Table of Contents 3 Contents Converting the Protocol of E2800 Host Ports (New Systems)...

More information

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC IBM System Storage N series IBM SnapDrive 7.1.4 for Windows Release Notes GC26-7881-28 Contents New in this release............................ 1 New features in SnapDrive 7.1.4 for Windows....................

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Clustered Data ONTAP 8.3 Volume Disaster Recovery Preparation Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC

IBM. SnapDrive for Windows Release Notes. IBM System Storage N series GC IBM System Storage N series IBM SnapDrive 7.1.2 for Windows Release Notes GC26-7881-26 Contents New in this release............................ 1 New features in SnapDrive 7.1.2 for Windows....................

More information

Simulate ONTAP 8.1 Installation and Setup Guide

Simulate ONTAP 8.1 Installation and Setup Guide Simulate ONTAP 8.1 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 USA Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation

More information

Replacing Failed Memory in the E2760 Controller-Drive Tray

Replacing Failed Memory in the E2760 Controller-Drive Tray Replacing Failed Memory in the E2760 Controller-Drive Tray To access this product, go to the NetApp Support Site at support.netapp.com. The controller canister in an E2760 controller-drive tray has both

More information

Replacing the chassis on a FAS22xx system

Replacing the chassis on a FAS22xx system Replacing the chassis on a FAS22xx system To replace the chassis, you must remove the power supplies, hard drives, and controller module or modules from the old chassis, remove the old chassis from the

More information

Replacing an NVMEM battery in a FAS22xx system

Replacing an NVMEM battery in a FAS22xx system Replacing an NVMEM battery in a FAS22xx system To replace an NVMEM battery in the system, you must remove the controller module from the system, open it, replace the battery, and close and replace the

More information

Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray

Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray Replacing a Failed Host Interface Card in the E2760 Controller- Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might

More information

Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray

Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray Replacing a Failed Controller Canister in the E5660 Controller- Drive Tray To access this product, go to the NetApp support site at mysupport.netapp.com. You can determine whether you have a failed controller

More information

Volume Disaster Recovery Express Guide

Volume Disaster Recovery Express Guide ONTAP 9 Volume Disaster Recovery Express Guide December 2017 215-11188_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster

More information

Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays

Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays E-Series Replacing a Drive in E2660, E2760, E5460, E5560, or E5660 Trays The Recovery Guru in SANtricity Storage Manager monitors the drives in the storage array and can notify you of an impending drive

More information

Inventory Collect Tool 1.4

Inventory Collect Tool 1.4 Inventory Collect Tool 1.4 Host and Storage Information Collection Guide For Transition Assessment NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Upgrading a Host Interface Card in the E5560 Controller-Drive Tray

Upgrading a Host Interface Card in the E5560 Controller-Drive Tray Upgrading a Host Interface Card in the E5560 Controller-Drive Tray ATTENTION Possible equipment damage Only a qualified service technician should perform this procedure, or equipment damage might result.

More information

OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View

OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View OnCommand Cloud Manager 3.2 Provisioning NFS Volumes Using the Volume View April 2017 215-12036_B0 doccomments@netapp.com Table of Contents 3 Contents Logging in to Cloud Manager... 4 Creating NFS volumes...

More information

Disaster Recovery for Enterprise Applications with ONTAP Cloud

Disaster Recovery for Enterprise Applications with ONTAP Cloud Technical Report Disaster Recovery for Enterprise Applications with ONTAP Cloud Step-by-Step Guide Shmulik Alfandari, NetApp September 2016 TR-4554i Abstract This document describes the required steps

More information

IBM. SnapDrive 5.3 for UNIX Release Notes (AIX, Linux, and Solaris) IBM System Storage N series GC

IBM. SnapDrive 5.3 for UNIX Release Notes (AIX, Linux, and Solaris) IBM System Storage N series GC IBM System Storage N series IBM SnapDrive 5.3 for UNIX Release Notes (AIX, Linux, and Solaris) GC26-7877-20 Contents Product overview............................. 1 New in this release............................

More information

NetApp Data ONTAP Edge on SoftLayer

NetApp Data ONTAP Edge on SoftLayer Technical Report NetApp Data ONTAP Edge on SoftLayer Express Setup Guide Jarod Rodriguez, NetApp April 2016 TR-4502 Abstract This document provides instructions on how to quickly install NetApp Data ONTAP

More information

All other components in the system must be functioning properly; if not, you must contact technical support.

All other components in the system must be functioning properly; if not, you must contact technical support. FAS25xx System For all operating environments Replacing a chassis To replace the chassis, you must remove the power supplies, fan modules, hard drives, and controller module or modules from the old chassis,

More information

Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray

Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray Upgrading Host Interface Cards in the E2712 or the E2724 Controller-Drive Tray To access this product, go to the NetApp Support Site at mysupport.netapp.com. Planning the Host Interface Card Upgrade Use

More information

V-Series Systems Implementation Guide for HP EVA Storage

V-Series Systems Implementation Guide for HP EVA Storage V-Series Systems Implementation Guide for HP EVA Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage

Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage March 2017 215-09444_B0 doccomments@netapp.com Table of Contents 3 Contents Preparing to use Windows hosts with ONTAP storage...

More information

Clustered Data ONTAP 8.2 Multiprotocol Server Configuration Express Guide

Clustered Data ONTAP 8.2 Multiprotocol Server Configuration Express Guide IBM System Storage N series Clustered Data ONTAP 8.2 Multiprotocol Server Configuration Express Guide SC27-6409-00 Contents Preface.................................... v About this guide..................................

More information

iscsi Configuration for Windows Express Guide

iscsi Configuration for Windows Express Guide ONTAP 9 iscsi Configuration for Windows Express Guide December 2017 215-11180_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

SNMP Configuration Express Guide

SNMP Configuration Express Guide ONTAP 9 SNMP Configuration Express Guide December 2017 215-11190_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 SNMP configuration

More information

SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter

SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter SnapCenter Software 3.0 Importing Data from SnapManager to SnapCenter July 2017 215-12093_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding on whether to read this information... 4 Importing

More information

Navigating VSC 6.1 for VMware vsphere

Navigating VSC 6.1 for VMware vsphere Navigating VSC 6.1 for VMware vsphere Virtual Storage Console for VMware vsphere works with the VMware vsphere Web Client and has dropped support for the VMware Desktop Client. This change means that VSC

More information

Cluster Peering Express Guide For 7-Mode Administrators Learning Cluster-Mode

Cluster Peering Express Guide For 7-Mode Administrators Learning Cluster-Mode Data ONTAP 8.1 Cluster Peering Express Guide For 7-Mode Administrators Learning Cluster-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Data ONTAP DSM 3.4 for Windows MPIO Release Notes

Data ONTAP DSM 3.4 for Windows MPIO Release Notes Data ONTAP DSM 3.4 for Windows MPIO Release Notes NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation

More information

Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards

Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards Replacing Controller Canisters in the E5560 Controller-Drive Tray to Upgrade Host Interface Cards To access this product, go to the NetApp support site at mysupport.netapp.com. Planning the Host Interface

More information

NDMP in Clustered Data ONTAP for Tape Backup Software Applications

NDMP in Clustered Data ONTAP for Tape Backup Software Applications Technical Report NDMP in Clustered Data ONTAP for Tape Backup Software Applications Subhash Athri, NetApp June 2015 TR-4376 TABLE OF CONTENTS 1 NDMP Backups... 3 1.1 Tape Backup Topologies in Clustered

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Clustered Data ONTAP 8.2 Multiprotocol File Access Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

Replacing a Power Canister in E5760 or E2860 Shelves

Replacing a Power Canister in E5760 or E2860 Shelves E-Series Replacing a Power Canister in E5760 or E2860 Shelves Each 60-drive controller shelf or drive shelf includes two power canisters for power redundancy. If a power canister fails, you must replace

More information

Data ONTAP-v Administration Tool 1.2

Data ONTAP-v Administration Tool 1.2 Data ONTAP-v Administration Tool 1.2 Installation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888) 463-8277

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Updated for 8.3.1 Clustered Data ONTAP 8.3 Using All Flash FAS with Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

NetApp E-Series Storage Systems Hardware Cabling Guide

NetApp E-Series Storage Systems Hardware Cabling Guide NetApp E-Series Storage Systems Hardware Cabling Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

NetApp E-Series Storage Array Replication Adapter Best Practices Guide

NetApp E-Series Storage Array Replication Adapter Best Practices Guide NetApp E-Series Storage Array Replication Adapter Best Practices Guide NetApp, Inc. Telephone: +1 (408) 822-6000 Part number: 215-08654_A0 495 East Java Drive Fax: +1 (408) 822-4501 Release date: November

More information

SnapManager 2.0 for Hyper-V

SnapManager 2.0 for Hyper-V SnapManager 2.0 for Hyper-V Release Notes NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com

More information

FC Configuration for Windows Express Guide

FC Configuration for Windows Express Guide ONTAP 9 FC Configuration for Windows Express Guide December 2017 215-11173_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration

More information

GC NA _A0

GC NA _A0 IBM System Storage N series Release Notes for Use with DataFabric Manager Server 4.0.2, Supporting Operations Manager, Protection Manager and Provisioning Manager GC26-7890-12 NA 210-05259_A0 Copyright

More information

Replacing a Power-Fan Canister in E5700 or E2800 Shelves

Replacing a Power-Fan Canister in E5700 or E2800 Shelves E-Series Replacing a Power-Fan Canister in E5700 or E2800 Shelves Each 12-drive or 24-drive controller shelf or drive shelf includes two power supplies with integrated fans. These are referred to as power-fan

More information

Building a Dynamic Cloud Environment

Building a Dynamic Cloud Environment Dynamic Cloud Solution Reference Architecture Building a Dynamic Cloud Environment The goal of this reference architecture is to provide IT management, architects, and designer s insight to configurations

More information

IBM. Snap Creator Framework 4.3 Release Notes. IBM System Storage N series GI

IBM. Snap Creator Framework 4.3 Release Notes. IBM System Storage N series GI IBM System Storage N series IBM Snap Creator Framework 4.3 Release Notes GI13-2801-06 Contents Product overview................................ 1 New in this release............................... 3 Fixed

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Clustered Data ONTAP 8.3 FC Configuration for ESX Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

FC Configuration for ESX Express Guide

FC Configuration for ESX Express Guide ONTAP 9 FC Configuration for ESX Express Guide March 2017 215-11179-C0 doccomments@netapp.com Updated for ONTAP 9.1 Table of Contents 3 Contents Deciding whether to use this guide... 4 FC configuration

More information

IBM. SnapManager for Oracle Release Notes. IBM System Storage N series GC

IBM. SnapManager for Oracle Release Notes. IBM System Storage N series GC IBM System Storage N series IBM SnapManager 3.4.1 for Oracle Release Notes GC27-2058-15 Contents Product overview............................. 1 New in this release............................ 3 Fixed

More information

Installing and Configuring for AIX

Installing and Configuring for AIX SANtricity System Manager 11.30 Installing and Configuring for AIX Express Guide August 2016 215-11221_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this Express Guide...

More information

All Flash FAS SAN-Optimized Configuration

All Flash FAS SAN-Optimized Configuration Technical Report All Flash FAS SAN-Optimized Configuration Michael Peppers, NetApp June 2016 TR-4480 Abstract This technical report provides details about the SAN-optimized configuration for NetApp All

More information

SolidFire and AltaVault

SolidFire and AltaVault Technical Report SolidFire and AltaVault Back Up SolidFire Storage to the Cloud by Using AltaVault Mike Braden, NetApp August 2016 TR-4542 Abstract Effectively using storage at scale is how organizations

More information

SMB/CIFS Configuration Express Guide

SMB/CIFS Configuration Express Guide ONTAP 9 SMB/CIFS Configuration Express Guide November 2017 215-11170_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 SMB/CIFS configuration

More information

NFS Client Configuration for ESX Express Guide

NFS Client Configuration for ESX Express Guide ONTAP 9 NFS Client Configuration for ESX Express Guide December 2017 215-11183_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 NFS

More information

Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray

Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray E-Series Replacing a Failed Controller Canister in a E2760 Controller- Drive Tray To replace a failed E2700 controller canister in a duplex configuration, you remove the controller canister from the E2760

More information

Windows Host Utilities Release Notes

Windows Host Utilities Release Notes IBM System Storage N series Windows Host Utilities 6.0.2 Release Notes GC52-1296-16 Contents Windows Host Utilities 6.0.2 Release Notes.................... 1 Important cautions............................

More information

iscsi Configuration for ESX Express Guide

iscsi Configuration for ESX Express Guide ONTAP 9 iscsi Configuration for ESX Express Guide December 2017 215-11181_D0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi configuration

More information

SnapDrive for UNIX Release Notes

SnapDrive for UNIX Release Notes IBM System Storage N series SnapDrive 5.0.1 for UNIX Release Notes GC26-7877-15 Contents SnapDrive 5.0.1 for UNIX Release Notes..................... 1 Limitations............................... 3 Fixed

More information

All other components in the system must be functioning properly; if not, you must contact technical support.

All other components in the system must be functioning properly; if not, you must contact technical support. 62xx systems For all operating environments Replacing a chassis To replace the chassis, you must remove the controller module or modules and I/O expansion module, when present, from the old chassis, remove

More information

Replacing a drive in E5724 shelves

Replacing a drive in E5724 shelves E-Series Replacing a drive in E5724 shelves The Recovery Guru in SANtricity System Manager monitors the drives in the storage array and can notify you of an impending drive failure or an actual drive failure.

More information

Adding a second controller module to create an HA pair operating in Data ONTAP 7-Mode

Adding a second controller module to create an HA pair operating in Data ONTAP 7-Mode Adding a second controller module to create an HA pair operating in Data ONTAP 7-Mode Upgrading a stand-alone controller module to HA pair is a multistep process involving both hardware and software changes

More information

Inventory Collect Tool 2.2

Inventory Collect Tool 2.2 Inventory Collect Tool 2.2 Host and Storage Information Collection Guide For Transition Assessment NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

System-Level Diagnostics Guide

System-Level Diagnostics Guide IBM System Storage N series System-Level Diagnostics Guide GA32-0839-01 Contents Preface................................ v About this guide............................. v Supported features.............................

More information

GC NA _A0. IBM System Storage N series Data ONTAP 7.3 Software Setup Guide

GC NA _A0. IBM System Storage N series Data ONTAP 7.3 Software Setup Guide GC27-2206-07 NA 210-05189_A0 IBM System Storage N series Data ONTAP 7.3 Software Setup Guide Table of Contents 3 Contents Copyright information... 7 Trademark information... 9 About this guide... 11 Audience...

More information

OnCommand Cloud Manager 3.0 Administration Guide

OnCommand Cloud Manager 3.0 Administration Guide OnCommand Cloud Manager 3.0 Administration Guide June 2016 215-11111_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Backing up Cloud Manager... 5 Removing

More information

NFS Configuration Express Guide

NFS Configuration Express Guide ONTAP 9 NFS Configuration Express Guide December 2017 215-11172_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 NFS configuration workflow...

More information

OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager

OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager OnCommand Cloud Manager 3.2 Updating and Administering Cloud Manager April 2017 215-12037_B0 doccomments@netapp.com Table of Contents 3 Contents Updating Cloud Manager... 4 Enabling automatic updates...

More information

Replacing a controller module in a 2240 system

Replacing a controller module in a 2240 system Replacing a controller module in a 2240 system To replace a controller module, you must remove the faulty controller module from the system and move the replaceable components from the old controller module

More information

OnCommand Insight 7.0

OnCommand Insight 7.0 OnCommand Insight 7.0 OnCommand Insight Getting Started Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

More information

All other components in the system must be functioning properly; if not, you must contact technical support.

All other components in the system must be functioning properly; if not, you must contact technical support. 80xx systems For all operating environments Replacing a chassis To replace the chassis, you must remove the power supplies, fan modules, and controller module or modules and I/O expansion module, when

More information

Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop

Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop Technical Report NetApp FAS and HBase Hadoop Online NoSQL with NetApp FAS NFS Connector for Hadoop Ankita Dhawale and Karthikeyan Nagalingam, NetApp September 2016 TR-4541 Abstract This document introduces

More information

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide The IBM System Storage N series Reference Architecture provides deployment

More information

Simulate ONTAP 8.2 Installation and Setup Guide

Simulate ONTAP 8.2 Installation and Setup Guide Simulate ONTAP 8.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com

More information

V-Series Systems Installation Requirements and Reference Guide

V-Series Systems Installation Requirements and Reference Guide V-Series Systems Installation Requirements and Reference Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

V-Series Systems Implementation Guide for Hitachi Storage

V-Series Systems Implementation Guide for Hitachi Storage V-Series Systems Implementation Guide for Hitachi Storage NetApp 495 East Java Drive Sunnyvale, CA 94089 USA Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP Documentation

More information

StorageGRID 9.0 Installation Guide

StorageGRID 9.0 Installation Guide StorageGRID 9.0 Installation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: http://www.netapp.com

More information

V-Series Systems Implementation Guide for RamSan Storage

V-Series Systems Implementation Guide for RamSan Storage V-Series Systems Implementation Guide for RamSan Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

iscsi Configuration for ESXi using VSC Express Guide

iscsi Configuration for ESXi using VSC Express Guide ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

HCI File Services Powered by ONTAP Select

HCI File Services Powered by ONTAP Select Technical Report HCI File Services Powered by ONTAP Select Quick Start Guide Aaron Patten, NetApp March 2018 TR-4669 Abstract NetApp ONTAP Select extends the NetApp HCI product, adding a rich set of file

More information