Dell EMC SC Series Storage: Microsoft Multipath I/O
|
|
- Henry Blair
- 6 years ago
- Views:
Transcription
1 Dell EMC SC Series Storage: Microsoft Multipath I/O Dell EMC Engineering June 2017 A Dell EMC Best Practices Guide
2 Revisions Date Description 10/11/2010 Initial release 10/21/2011 Corrected errors 11/29/2011 Additional content on Microsoft Windows Server Core 10/15/2012 Updated to include Windows Server 2012 content 5/29/2013 Updated to include Windows Server 2008 R2/2012 iscsi initiator setup and appendix listing recommended hotfixes and registry values 10/18/2013 Updated to include Windows Server 2012 R2 content 1/10/2014 Updated hotfix information 1/12/2015 Updated configuration recommendations 3/3/2015 Updated hotfix and configuration recommendations 4/17/2015 Added Dell SCv2000 series front-end SAS content 2/9/2016 Removed Windows Server 2003 content and updated hotfix recommendations 10/4/2016 Re-ordered document for clarity, added Windows Server 2016 and Nano Server content, and updated hotfix recommendations 1/20/2017 Updated configuration recommendations 6/30/2017 Updated hotfix info and configuration recommendations Acknowledgements Author: Kris Piepho The information in this publication is provided as is. Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
3 Table of contents Revisions... 2 Acknowledgements Preface Audience Introduction to Microsoft Multipath I/O SC Series storage connections Legacy port mode Virtual port mode Connectivity summary Configuring servers Fibre Channel iscsi SAS Automatic configuration of Fibre Channel and iscsi-connected servers Manual configuration of Fibre Channel and iscsi-connected servers Configuring a SAS server Automatic configuration Manual configuration Verifying Fibre Channel and iscsi connectivity Verifying SAS connectivity Restrict volume mapping paths (Fibre Channel and iscsi only) Restrict mapping paths on SAS-connected volumes Choose the I/O transport Installing MPIO Installing the MPIO feature on Windows Server 2008 R Server manager GUI Windows Server manager CLI To install MPIO on Server Core Installing the MPIO feature on Windows Server 2012 or later Server manager GUI PowerShell Configuring MPIO Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
4 5.1 Associating SC Series volumes with the Microsoft DSM Using the MPIO control panel Using PowerShell (Server 2012 or later) Using the MPCLAIM command Setting the default load balance policy Using the MPCLAIM command Using PowerShell (Server 2012 or later) Per-volume load balance settings Using the disk management GUI: Using the MPCLAIM command Configure a Windows Server 2008 R2 or later for iscsi MPIO Configuration MPIO on Windows Nano Server Enable MPIO Associating SC Series volumes with the Microsoft DSM Configuring iscsi A Windows Server single-path and MPIO configuration recommendations for SC Series storage A.1 Recommended updates and hotfixes for Windows Server 2008 R2 SP A.2 Recommended updates and hotfixes for Windows Server 2012 (non-r2 version) A.3 Recommended updates and hotfixes for Windows Server 2012 R A.4 Recommended updates and hotfixes for Windows Server A.5 Recommended registry settings for Windows Server A.6 iscsi initiator settings (single-path and MPIO) A.7 PowerShell script A.8 Resources B Additional resources B.1 Technical support and resources B.2 Related documentation Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
5 1 Preface This document provides an overview of Multipath I/O (MPIO) and introduces best practice guidelines for configuring MPIO on Microsoft Windows Server 2008 R2, 2012, 2012 R2, 2016, and Nano Server when using a Dell EMC SC Series array. 1.1 Audience This document was written for system administrators responsible for the setup and maintenance of Windows servers and associated storage. Readers should have a working knowledge of Windows Server and SC Series arrays. 5 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
6 2 Introduction to Microsoft Multipath I/O Microsoft MPIO is a framework that allows administrators to configure load balancing and failover processes for Fibre Channel, iscsi, and SAS connected storage devices. Load balancing can be configured to use up to 32 independent paths from the connected storage devices. SC Series arrays provide redundancy and failover with multiple controllers and RAID modes. However, servers still need a way to spread the I/O load and handle internal failover from one path to the next. This is where MPIO plays an important role. Without MPIO, servers see multiple instances of the same disk device in Windows disk management. The MPIO framework uses Device Specific Modules (DSM) to allow path configuration. Microsoft provides a built-in generic Microsoft DSM (MSDSM) for Windows Server 2008 R2 and above. This MSDSM provides the MPIO functionality for Dell EMC storage customers. 2.1 SC Series storage connections Before reviewing server-specific MPIO functions, it is important to understand that various connection options are available with the SC Series arrays that allow multiple paths to be presented to the servers. The following section provides a quick overview and explains the differences between legacy port mode and virtual port mode. This overview does not take the place of the Storage Center Connectivity Guide available on the Dell SC Series Customer Portal (login required) Legacy port mode In legacy port mode, the front-end I/O ports are designated as either primary or reserve ports based on a fault domain. Primary and reserved ports allow I/O to use the primary path; the reserve port is in a standby mode until a primary port fails over to the reserve port. In terms of MPIO, this requires twice as many I/O ports to enable multiple paths. Even more ports are required for a dual fabric. Figure 1 illustrates dual-fabric failover ports in legacy mode. Legacy mode example with Fibre Channel 6 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
7 As shown in Figure 1, a dual-controller SC Series array in legacy mode is connected to a Fibre Channel server with two fault domains. Fault domain 1 (shown in orange) is comprised of primary port P1 on controller A and reserved port R1 on controller B. Fault domain 2 (shown in green) is comprised of primary port P2 on controller B and reserved port R2 on controller A Virtual port mode Virtual port mode provides port and storage controller redundancy by connecting multiple active ports to each Fibre Channel or Ethernet switch. In virtual port mode, each physical port has a WWN (World Wide Name) and a virtual WWN. Servers target only the virtual WWNs. During normal conditions, all ports process I/O. If a port or storage controller failure occurs, a virtual WWN moves to another physical WWN in the same fault domain. When the failure is resolved and ports are rebalanced, the virtual port returns to the preferred physical port. Virtual port mode provides the following advantages over legacy mode: Increased connectivity: Because all ports are active, additional front-end bandwidth is available without sacrificing redundancy. Improved redundancy: - Fibre Channel: A Fibre Channel port can fail over to another Fibre Channel port in the same fault domain on the storage controller. - iscsi: In a single fault domain configuration, an iscsi port can fail over to the other iscsi port on the storage controller. In a two fault domain configuration, an iscsi port cannot fail over to the other iscsi port on the storage controller. Simplified iscsi configuration: Each fault domain has an iscsi control port that coordinates discovery of the iscsi ports in the domain. When a server targets the iscsi port IP address, it automatically discovers all ports in the fault domain Fibre Channel To use virtual ports for Fibre Channel, all Fibre Channel switches and host bus adapters (HBAs) must support N_Port ID Virtualization (NPIV). As shown in Figure 2, a dual-controller SC Series array in virtual port mode is connected to a Fibre Channel (FC) server with a single fault domain. All ports belong to a single fault domain because they are connected to the same FC switch. 7 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
8 Virtual ports example with Fibre Channel iscsi iscsi follows the same wiring and port setup as Fibre Channel with the exception of the control port. iscsi uses a control port configured for each of the fault domains. Servers connect to the control port, which then redirects traffic to the appropriate virtual port. When configuring MPIO, this looks slightly different than with the legacy mode configuration because only the control port in the iscsi initiator software needs to be assigned. These differences are covered below in the OS-specific sections SAS With select SC Series models that support SAS front-end connectivity, hosts or servers can access storage by connecting directly to SC Series SAS ports. In SAS virtual port mode, a volume is active on only one storage controller, but is visible to both storage controllers. Asymmetric Logical Unit Access (ALUA) controls the path that a server uses to access a volume. If a storage controller becomes unavailable, the volume becomes active on the other storage controller. The state of the paths on the available storage controller are set to Active/Optimized and the state of the paths on the other storage controller are set to Standby. When the storage controller becomes available again and the ports are rebalanced, the volume moves back to its preferred storage controller and the ALUA states are updated. If a SAS path becomes unavailable, the Active/Optimized volumes on that path become active on the other storage controller. The state of the failed path for those volumes is set to Standby and the state of the active path for those volumes is set to Active/Optimized. Note: Failover in SAS virtual port mode occurs within a single fault domain. Therefore, a server must have both connections in the same fault domain. For example, if a server is connected to SAS port two on one storage controller, it must be connected to SAS port two on the other storage controller. If a server is not cabled correctly when a storage controller or SAS path becomes unavailable, access to the volume is lost. 8 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
9 In the example shown in Figure 3, four fault domains are spread across both storage controllers. The storage controllers are connected to each host server using four SAS connections. If a storage controller port fails, the virtual port on the failed port moves to the other storage controller. Storage system connected to two host servers Connectivity summary There are two methods to enable multiple paths from an SC Series array: legacy port mode and virtual port mode. Virtual ports are preferred because they reduce the number of HBAs required, reducing cost and overhead. Note that virtual ports are enabled based on protocol: virtual ports can be enabled on Fibre Channel only, iscsi only, SAS only, both Fibre Channel and iscsi, or both SAS and iscsi. 9 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
10 3 Configuring servers Before configuring MPIO at the operating system level, first configure servers using Dell Storage Manager. The following example assumes a server has two or more of the following types of connections: Fibre Channel ports that are zoned to see the SC Series HBAs iscsi I/O ports that are in a VLAN that can see the SC Series HBAs SAS ports directly connected to the SC Series HBAs With Fibre Channel, the process is the same for virtual ports as it is for legacy ports. However, with legacy ports, the server cannot see reserve ports. iscsi virtual ports connect only to an SC Series control port. 3.1 Fibre Channel To create the server, properly zone the switches so that the server and controller ports are in the same zone. Boot the server into the card BIOS and scan the SCSI devices on each port. An alternate method is to preconfigure the WWNs of the HBAs in the System Manager. 3.2 iscsi As with Fibre Channel, an iscsi server can be created automatically or manually. For automatic configuration, enter the IP address of the SC Series controller HBA ports in the server iscsi HBA or initiator software. Use either the HBA BIOS or the software initiator configuration wizard. In virtual port mode, enter the IP address of the control port. In legacy port mode, enter the IP address of the primary port. This is covered in more detail in the OS specific sections. 3.3 SAS To configure a Windows server directly connected to an SC Series unit by SAS, it is highly recommended to use the wizard. Configure this host to access an array in the Dell Storage Manager client. The wizard will automatically create a server object on the array, detect all available paths, and assign them to the server, as well as automatically apply recommended MPIO registry settings to the server. MPIO registry settings are discussed in detail in appendix A. A directly connected SAS server can also be created automatically or manually using a Dell Storage Manager client. Refer to section 3.6, Configuring a SAS server, for details on creating a SAS server. 10 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
11 3.4 Automatic configuration of Fibre Channel and iscsi-connected servers Once a server has scanned for devices or logged into the target, the SC Series array automatically recognizes the WWN/IQN. To configure a server: 1. Log in to the Dell Storage Manager client. 2. In the tree view, right-click Servers. 3. From the shortcut menu, select Create Server. 4. Select the appropriate HBAs and continue the wizard. If the HBA does not appear, refer to section 3.5, Manual configuration. Note: If the WWN or IQN is not listed, make sure that the Only Show Up Connections box is not checked. Create Server window 11 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
12 3.5 Manual configuration of Fibre Channel and iscsi-connected servers To manually configure an HBA: 1. In the Create Server wizard shown in Figure 4, click Manually Add HBA. 2. In the Select Transport Type window, choose Fibre Channel or iscsi. 3. Enter the WWN or iscsi name, and click Continue. Repeat steps 1-3 for every WWN or iscsi HBA to be associated with the server. 4. Once all of the HBAs are added, check the appropriate HBA and continue the wizard. Note: The new HBA appears with a white X in a red circle. Once the server is connected the warning state is removed. Manually defined HBA 3.6 Configuring a SAS server Automatic configuration To configure a server: 1. Log in to the SC Series array using the Dell Storage Manager client. 2. Select the Storage tab. 3. In the tree view, right-click Servers. 4. From the shortcut menu, select Create Server. 12 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
13 5. In the Create Server window, assign the server a name. 6. Select a server folder (if applicable). 7. Select an operating system (Windows Server 2008 MPIO or Windows Server 2012 MPIO only). 8. Select the available HBA(s) and click OK. 13 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
14 3.6.2 Manual configuration To manually configure a SAS HBA: 1. In the Create Server window, click Manually Add HBA. 2. In the Manually Add HBA window, enter the SAS HBA WWN. 3. Select SAS in the HBA Port Type drop-down menu and click OK. 4. Repeat steps 1-3 to associate more SAS HBAs with the server. 5. Once all HBAs are added, check the appropriate HBA and continue the wizard. Note: The new HBA appears with a white X in a red circle. Once the server is connected the warning state is removed. 14 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
15 3.7 Verifying Fibre Channel and iscsi connectivity To ensure correct connectivity: 1. Login to the Dell Storage Manager client. 2. In the tree view, select a server. 3. Click Connectivity. This window shows all paths available to the server based on the HBA and controller ports. Fibre Channel connectivity The connectivity tab displays the HBAs that are defined for the server object and the SC Series array HBAs/control ports the server HBAs are attached to. In the example shown in Figure 6, there are a total of eight possible paths because each of the two Fibre Channel HBA ports on the server can see four Fibre Channel HBA ports assigned to each fault domain. 15 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
16 iscsi connectivity In the example shown in Figure 7, there are a total of four possible paths because each of the two iscsi NICs on the server can see two iscsi control ports assigned to each fault domain. 3.8 Verifying SAS connectivity To ensure correct SAS connectivity: 1. Log in to the Dell Storage Manager client. 2. Click the Storage tab. 3. In the tree view, select a server. 4. Click Connectivity. This view will show all defined SAS HBAs, and paths to ports on the top and bottom controllers. 16 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
17 SAS connectivity 3.9 Restrict volume mapping paths (Fibre Channel and iscsi only) An SC Series volume is mapped to all available paths unless the advanced mapping button is used to restrict mapping paths to FC only, iscsi only, or specified HBA ports and controller ports. To restrict mapping paths: 1. Log in to the Dell Storage Manager client. 2. In the tree view, right-click a volume and select Map Volume to Server. The Map Volume to Server window appears. 3. Select a server and click Continue. The Map Volume window appears. 4. Click Advanced Options. 5. Under Restrict Mapping Paths, uncheck the box to Map to All Available Ports. 6. Select one of the following: - Map using specific server ports (check the specific server ports) - Limit ports by transport type (select a transport from the drop-down menu) Note: The option to limit ports by transport type is only available on systems that have more than one transport type available, such as both Fibre Channel and iscsi. Note: Using mixed transports concurrently on the same Windows server host is not supported with Server 2012 R2 and newer. With Server 2012 R2 and newer, when a LUN is presented to the host that is using multiple transports such as Fibre Channel and iscsi, the host will default to one transport or the other (typically Fibre Channel is chosen by the host) and ignore the other transport. If all paths for one type of transport go down, the host may not send data using the other transport without a disk re-scan. This is default Windows Server behavior. 17 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
18 Map using specific server ports Limit ports by transport type Assuming the default mapping wizard is used and paths are not restricted, a volume is mapped to all available paths, creating multiple I/O paths from the server to the volume. To view the mapped paths, select a volume in the tree view and click the Mappings tab. 18 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
19 Figure 11 shows MPIO 500GB_Volume mapped to the server with four FC ports and two iscsi ports. Volume mapping tab 3.10 Restrict mapping paths on SAS-connected volumes To restrict mapping paths on SAS-connected volumes: 1. Log in to Dell Storage Manager client. 2. Click the Storage tab. 3. In the tree view, right-click a volume and select Map Volume to Server. The Map Volume to Server wizard appears. 4. Select a server and click Next. 5. Select Advanced Options. 6. Under Restrict Mapping Paths, uncheck Map to All Available Server Ports. 7. Select the HBA(s) to use when mapping this volume. 8. Click Finish to map the volume to the selected server. 19 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
20 Restrict mapping paths To view the mapped paths, select a volume in the tree view and click the Mappings tab. Figure 13 shows volume SAS MPIO Volume mapped to the server with all available SAS ports. Volume mappings tab 20 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
21 3.11 Choose the I/O transport Dell EMC offers the following I/O transports: 8GB, 16GB, and 32GB Fibre Channel (SCv9000 series only), 10GB iscsi, and 12GB SAS. Choosing an I/O transport method largely depends on the current infrastructure in an organization and its future plans. Fibre Channel offers better performance than iscsi, but requires a dedicated infrastructure. For a converged fabric, iscsi is the best option because it can utilize existing networking infrastructure. For smaller organizations without existing infrastructure or environments where directly-attached storage is preferred, SAS offers excellent performance for a simple, cost-effective solution. It is recommended that there are multiple front-end controller paths to the servers and that the servers have multiple connections to the controller. Note: Windows Server 2012 or later includes the ability to use heterogeneous HBA types with MPIO. In previous versions of Windows Server, it was a requirement to use HBAs of the same model. 21 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
22 4 Installing MPIO Beginning with Windows Server 2008, Microsoft includes a built-in DSM that manages all aspects of failover and load balancing. Dell EMC storage uses this DSM because it provides all the functionality required for our customers. This also simplifies implementation, as it eliminates the need to install and maintain another piece of software in the environment. The Microsoft DSM is not functional on Windows Server until the MPIO feature is installed. The Microsoft DSM for Windows Server can manage iscsi, FC, and SAS volumes. Note: MPIO is required for directly-connected SAS volumes and is only supported on Windows Server 2008 R2 or later. Please refer to appendix A in this document for important Windows Server 2008 R2 MPIO configuration recommendations. 4.1 Installing the MPIO feature on Windows Server 2008 R2 On Windows Server 2008 R2, the MPIO feature can be installed using Server Manager. Server Manager offers two options for installing the MPIO feature: the Server Manager graphical unit interface (GUI) or the servermanagercmd command line interface (CLI). To access Server Manager, click Start > Control Panel > Administrative Tools > Server Manager, or click the Server Manager icon in the taskbar Server manager GUI To install using the Server Manager GUI: 1. Open Server Manager. 2. In the tree view, click Features. 3. Under Features Summary, click Add Features. 4. Check MPIO and click Next. 5. Click Install. Once the feature has been installed click Yes, if prompted, to allow the reboot Windows Server manager CLI To install using the CLI, open a command prompt with elevated (administrator) privileges and type: Servermanagercmd -install "Multipath-IO" To install MPIO on Server Core For a Window Server 2008 R2 Core installation, open a command prompt and type: DISM /online /enable-feature:multipathio Note: For Windows Server Core installations, the prior commands are case sensitive. 22 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
23 4.2 Installing the MPIO feature on Windows Server 2012 or later The MPIO feature can be installed on Windows Server 2012 or later either through the Server Manager GUI or through the MPIO module in Microsoft PowerShell. Note: On Windows Server 2012 and 2012 R2 Core installations, follow the instructions for PowerShell. To access PowerShell on a Server Core installation, type powershell and press Enter at the command prompt Server manager GUI 1. Open Server Manager. 2. From the Dashboard, click Add roles and features. 3. When the Add Roles and Features Wizard window opens, click Next. 23 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
24 4. Select Role-based or feature-based installation and click Next. 5. Choose the local server, and click Next. 6. Without selecting a role to install, click Next on the Select server roles screen. 7. Check Multipath I/O and click Next. 8. Check the box to restart the destination server automatically if required. 9. Click Install. 10. Click Close when finished. 24 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
25 4.2.2 PowerShell 1. Open a PowerShell window with elevated (administrator) privileges. 2. At the PowerShell prompt, enter the following command: Enable-WindowsOptionalFeature Online FeatureName MultiPathIO Note: When installing the MPIO feature using PowerShell on Windows Server 2016, the user is prompted to restart the server to complete installation: If possible, it is recommended to reboot the server immediately. To bypass the reboot prompt, specify the -NoRestart option at the end of the PowerShell command: 25 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
26 5 Configuring MPIO This section describes how to associate the Microsoft DSM with SC Series volumes and how to set up and configure the Microsoft DSM based on the failover and load balancing policies of an organization. These instructions assume that servers have been created in Dell Storage Manager and that at least one volume is mapped to the server using FC, iscsi, or SAS with MPIO enabled. Note: When the MPIO configuration is complete, refer to appendix A for important MPIO-specific hotfix and registry settings. 5.1 Associating SC Series volumes with the Microsoft DSM At this point, the Microsoft MPIO DSM has been installed but not configured. SC Series volumes must be associated with the DSM so that it can manage MPIO characteristics. The Microsoft DSM manages all Fibre Channel, iscsi, and SAS volumes presented. The built-in iscsi initiator or an iscsi HBA can also be used with the same management for the iscsi Multipath I/O. Note: The software iscsi initiator included in Windows Server 2008 R2 or later provides the necessary performance and stability required for iscsi connections to an SC Series array. However, Dell supports the use of an iscsi HBA Using the MPIO control panel To associate the SC Series volumes with the DSM through the use of the MPIO Control Panel, follow these steps: 1. Open the MPIO control panel by clicking Start > Administrative Tools > MPIO. 2. Click the Discover Multi-Paths tab. 26 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
27 3. Under Others, COMPELNTCompellent Vol should be displayed. Note: If COMPELNTCompellent Vol does not appear, rescan disk devices in Disk Management. 4. Highlight COMPELNTCompellent Vol, and click Add. 5. Click Yes on the Reboot Required window. 6. Once the server has rebooted, open the MPIO Control Panel and verify that COMPELNTCompellent Vol is listed under Devices on the MPIO Devices tab. 7. Click OK to close the window. 27 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
28 5.1.2 Using PowerShell (Server 2012 or later) Windows Server 2012 or later includes the MPIO module in Windows PowerShell. The MPIO module is a powerful alternative to using the mpclaim command. Although the mpclaim command is also included in Windows Server 2012 and above, Microsoft recommends using the MPIO module in PowerShell. To associate the SC Series volumes with the DSM through the use of PowerShell, follow these steps. 1. Open a PowerShell window with elevated (administrator) privileges. a. On Server Core installations, type powershell and then press [Enter] at the command prompt. 2. At the PowerShell prompt type: New-MSDSMSupportedHW VendorID "COMPELNT" ProductID "Compellent Vol" Note: On Windows Server 2016, if the server has not been rebooted after the MPIO feature installation, the prior command will fail. In this case, reboot the server and re-run the command to associate SC Series volumes with the DSM. 3. Now that SC Series storage is supported through the Microsoft DSM, claim all available SC volumes to be used by MPIO by typing: Update-MPIOClaimedHW Confirm:$false 4. Restart the server by typing: shutdown r t 0 [Enter] Using the MPCLAIM command The MPCLAIM CLI command can also be used to associate SC Series volumes with the Microsoft DSM. Open a command prompt with elevated (administrator) privileges and type the following: mpclaim.exe -r -i -d "COMPELNTCompellent Vol" This command provides the same result as the MPIO Control Panel and PowerShell options. It associates SC Series volumes and then restarts the server. To bypass the reboot option (if rebooting later is desired), use -n in place of -r. Once the server reboots, use Disk Management to verify that the configuration is correct. There should only be one instance of each SAN volume listed in Disk Management. 28 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
29 5.2 Setting the default load balance policy Once the SC Series volumes are associated with the Microsoft DSM, specify the default load balance policy and change any existing volumes to use the new policy. The default load balancing policy can be changed system-wide or on a per-volume basis. For SCOS versions 6.5 and earlier, the default load balance policy for SC Series volumes is round robin. Note: Failover only and round robin are the only MPIO load balancing policies supported on SCOS versions 6.5 and earlier. For SCOS version 6.6 and later, Fibre Channel and iscsi-connected volumes (both single and multi-path) will default to round robin. SAS-connected volumes default to round robin with subset. SC Series volumes mapped with both Fibre Channel and iscsi transports will default to round robin. Volumes mapped with both SAS and iscsi will default to round robin with subset. Note that on SCOS 6.6 and later: Failover only, round robin, and least queue depth are the only MPIO load balancing policies supported on Fibre Channel and iscsi volumes. SC series SAS-connected volumes support the following MPIO load balancing policies: round robin with subset, least queue depth and weighted paths Using the MPCLAIM command To use the MPCLAIM command to change the default load balance policy, open a command prompt with elevated (administrator) privileges and type the following: mpclaim.exe -L -M <0-7> -d "COMPELNTCompellent Vol" <0-7> refers to the desired load balance policy as shown in Table 1. Parameter MPCLAIM load balancing options Definition 0 Clear the policy 1 Failover only 2 Round robin 3 Round robin with subset 4 Least queue depth 5 Weighted paths 6 Least blocks 7 Vendor specific 29 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
30 For example, to change all SC Series volumes to a failover only policy, use the following command: mpclaim.exe -L -M 1 -d "COMPELNTCompellent Vol" Using PowerShell (Server 2012 or later) The MPIO module in PowerShell provides the ability to set the default load balance policy to round robin (RR), failover only (FOO), least blocks (LB), or least queue depth (LQD). To change the default load balancing policy to failover only, open a PowerShell window with elevated (administrator) privileges and type: Set-MSDSMGlobalDefaultLoadBalancePolicy Policy "FOO" To change the default load balancing back to round robin, type: Set-MSDSMGlobalDefaultLoadBalancePolicy Policy "RR" To verify the default load balance policy, type: Get-MSDSMGlobalDefaultLoadBalancePolicy If the default policy is set to round robin, the result will return RR: If the default policy is set to failover only, the result will return FOO: 5.3 Per-volume load balance settings Now that the default policy is set, it is important to understand how to change the policy on a per-volume basis. Some organizations may require a different policy based on the type of application or service provided. Use Disk Management or the MPCLAIM utility to change the per-volume policy. Note: The PowerShell MPIO module does not include cmdlets that can change the default load balancing policy on a specific volume. 30 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
31 5.3.1 Using the disk management GUI: 1. Click Start > Administrative Tools > Computer Management. 2. In the tree view, click Storage > Disk Management. 3. Right-click the desired disk number and select Properties. 4. Select the MPIO tab. 5. From the drop-down menu, select the appropriate MPIO policy for the volume. 31 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
32 5.3.2 Using the MPCLAIM command Note: The load balancing policy cannot be changed from round robin to failover only using the MPCLAIM command. MPCLAIM only supports switching from failover only to round robin. To change the default load balancing policy on a single volume, open a command prompt or PowerShell window with elevated (administrator) privileges (commands will work in both). To list all MPIO volumes on the system, type: mpclaim s d Figure 14 shows that the load balancing policy (LB Policy) is set to RR (round robin) for disks 0 and 1. Listing MPIO volumes The syntax to change the load balancing policy on a specific volume is: mpclaim l d <disk #> <0-7> Refer to Table 1 for load balancing policies and the associated numbers for the mpclaim command. To change the load balancing policy of MPIO disk 2 to round robin, type: mpclaim l d 2 2 Verify the new settings by typing: mpclaim s d To verify MPIO settings, refer to Microsoft TechNet for the full MPCLAIM reference guide. 32 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
33 6 Configure a Windows Server 2008 R2 or later for iscsi MPIO Windows Server 2008 R2 or later supports MPIO with the iscsi software initiator. iscsi initiator software is provided natively by the Windows Server OS. Note: For instructions on how to configure Windows Nano Server for iscsi MPIO, refer to section 7, MPIO on Windows Nano Server. The iscsi quick connect feature works well for single iscsi path connectivity. Configuring iscsi to use MPIO requires a few more steps, but is still easy to configure. Figure 15 represents a dual-controller SC Series array that is configured with virtual front-end ports with two fault domains. Two physical iscsi ports (one from each controller) are grouped logically as a virtual domain that is assigned a virtual iscsi IP address. Each virtual domain physical port is connected to two separate iscsi switches to ensure full path redundancy to the dual iscsi NICs on the server. iscsi virtual ports and domains 33 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
34 6.1 Configuration The environment created for this configuration is illustrated in Figure 15 and includes: Windows Server 2008 R2 or later Two dedicated NIC ports (one for each fault domain) on the server for iscsi communications An SC Series array with dual controllers configured with virtual front-end iscsi ports and two virtual fault domains The MPIO feature installed on the server To configure the server for iscsi MPIO, complete the following steps. 1. Configure two physical NIC ports on the server to use iscsi. 2. Configure one NIC (including the necessary cabling and switching configurations) to access one virtual iscsi domain, and configure the second NIC to access the other virtual iscsi domain. 3. In the example shown in Figure 15, the server NICs are assigned with IPs of (for fault domain 100), and (for fault domain 200). 4. Once configured, the server should be able to ping both of the virtual iscsi IP addresses associated with the two fault domains on the array. In this example, (fault domain 100) and (fault domain 200). 5. Log on to the Windows server and launch the iscsi initiator software. 6. Go to Start > Administrative Tools > iscsi Initiator. Note: If receiving a prompt to start the iscsi service, click Yes. 7. Select the Discovery tab, and click Discover Portal. 34 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
35 8. Enter the IP address of the first iscsi control port (in this example, the virtual iscsi IP address associated with the first fault domain on the array), and click Advanced. 9. From the Local adapter drop-down menu, select Microsoft iscsi Initiator. From the Initiator IP drop-down menu, select the local IP address of the server NIC that is to be associated with the first fault domain (fault domain 100). This example uses Initiator IP Click OK, and then OK again to return to the iscsi Initiator properties window. 11. Verify that the target IP address and adapter IP address are displayed in the Target portals section. 12. Repeat steps 1-11 to add the second target IP for the second virtual fault domain and the server second iscsi NIC (in this example, and ). 35 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
36 13. When completed, both pairs of iscsi initiators and targets are listed. 14. Select the Targets tab. This should be populated with the discovered iscsi target ports on the array. 15. Highlight the first target, and click Connect. 16. On the Connect To Target screen, verify that both Add this connection to the list of Favorite Targets and Enable multi-path are checked. 17. Click Advanced to display additional options. 36 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
37 18. Set Local adapter to Microsoft iscsi Initiator. 19. Select the correct IP addresses for the Target portal IP and Initiator IP from the drop-down menus. 20. Click OK, and then OK again to return to the iscsi Initiator properties window. 21. Repeat steps for each additional target listed. 22. When finished, all the targets show a Connected status. 23. Click OK to exit the iscsi Initiator Properties window. 37 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
38 7 MPIO on Windows Nano Server Nano Server is a new deployment option for Windows Server Nano Server is a headless, lightweight, more secure version of Windows Server that requires fewer updates and restarts. Nano Server includes PowerShell 5.1 Core Edition. PowerShell Core Edition was built to run on reduced footprint editions of Windows such as Nano Server, and contains fewer modules and cmdlets than the Desktop Edition, which is included with Windows Desktop and Core editions. Nano Server can be administered through a remote PowerShell connection, or by using GUI tools on a full Windows Server 2016 installation. All the commands in this section are issued through a remote PowerShell session (PSsession) to the Nano Server. For more information about Nano Server, refer to the Getting Started with Nano Server page on Microsoft TechNet. 7.1 Enable MPIO At the PowerShell prompt, enter the following command: Enable-WindowsOptionalFeature Online FeatureName "MultiPathIO" When prompted, answer Yes to restart Nano Server immediately, or No to restart the server later. After restarting Nano, re-establish a remote PowerShell connection to the Nano Server. To verify MPIO is enabled, type the following command: (Get-WindowsOptionalFeature Online FeatureName "MultiPathIO").State The command will return Enabled if the MPIO feature is working properly. 38 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
39 7.2 Associating SC Series volumes with the Microsoft DSM Unlike previous versions of Windows Server, Nano Server does not include the MPIO PowerShell module or the mpclaim command. A Microsoft-provided PowerShell script must be run on the Nano Server to associate SC Series volumes with the Microsoft DSM. The script and instructions for using it can be found on TechNet. Keep in mind that when running the MPIO claim script, the load-balance policy is chosen dynamically and cannot be modified. All Fibre Channel and iscsi-connected SC Series volumes will use round robin as the load balance policy. SAS-connected SC Series volumes will use round robin with subset as the default policy. By default, the script will configure the server to claim all volumes on all transports (FC, iscsi, and SAS). If desired, the script can be configured to claim volumes on a specific transport. A reboot is required when the script has completed running. 7.3 Configuring iscsi Nano Server includes a software iscsi initiator which is configured through PowerShell. The Nano Server iscsi initiator supports both single-path and multi-path connections to iscsi-connected SC Series volumes. For the examples that follow, the Nano Server will be configured to connect to a dual-controller SC Series array configured with two iscsi fault domains. The Nano Server has two dedicated NIC ports that will be used for iscsi traffic (one port for each SC Series fault domain). By default, the iscsi service is not running on a Nano Server. The service must be started, and the service must all be set to start automatically when the server starts. To start the iscsi service, type: Start-Service Name "MSiSCSI" To verify the iscsi service is running, type: Get-Service Name "MSiSCSI" The Status shows Running. 39 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
40 To set the iscsi server to automatic startup: 1. Type the following: Set-Service Name "MSiSCSI" StartupType "Automatic" 2. Establish a connection to the first SC Series iscsi fault domain. New-IscsiTargetPortal TargetPortalAddress "<fault domain 1 IP Address>" ` -InitiatorPortalAddress "<iscsi adapter 1 IP address>" ` -InitiatorInstanceName "ROOT\ISCSIPRT\0000_0" 3. Obtain a list of targets on the established portal. Get-IscsiTarget 40 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
41 4. Connect to each target listed, enabling multipath and making the connection persistent. Connect-IscsiTarget IsMultipathEnabled $true NodeAddress ` "<SC node address>" -InitiatorPortalAddress "<iscsi adapter 1 IP address>" ` -IsPersistent $true 5. Repeat this process for all the targets listed in Get-IscsiTarget: 41 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
42 6. When the targets are connected, use Get-IscsiTarget to view the IsConnected status as True for each node address. 7. View active iscsi connections. Get-IscsiConnection 8. Establish a connection to the second SC Series iscsi fault domain. New-IscsiTargetPortal TargetPortalAddress "<fault domain 2 IP Address>" ` -InitiatorAddress "<iscsi adapter 2 IP address>" ` -InitiatorInstanceName "ROOT\ISCSIPRT\0000_0" 42 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
43 9. Obtain a list of targets on the established portal to the second fault domain. Get-IscsiTarget 10. Connect to each target that is not connected to enable multipath and make the connection persistent. Connect-IscsiTarget IsMultipathEnabled $true NodeAddress ` "<SC node address>" -InitiatorPortalAddress "<iscsi adapter 2 IP address>" ` -IsPersistent $true 43 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
44 11. Repeat this process for any other non-connected targets listed in Get-IscsiTarget. 12. All items shown in Get-IscsiTarget should now show as connected: At this point iscsi connectivity between the Nano Server and SC Series array has been established. A server object can now be created on the SC Series array, allowing volumes to be mapped to the Nano Server using the iscsi transport method. For detailed instructions on how to create a server object on an SC Series array, refer to section 3, Configuring servers. 44 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
45 A Windows Server single-path and MPIO configuration recommendations for SC Series storage Note: The recommended updates and hotfixes in this section list the names (msdsm.sys, mpio.sys, storport.sys, and msiscsi.sys) and modified dates of storage-specific files that are loaded when the associated update or hotfix is applied. If a newer version of the file listed is already loaded on the server, the recommended update or hotfix does not need to be loaded. Note: In some cases, prerequisite updates must be installed on the server before the following hotfixes can be installed. Please read the prerequisite information for each applicable hotfix before proceeding. Note: Updates and hotfixes are listed in the order in which they should be installed. Note: The registry settings below should be made on all Windows Server hosts that use the Microsoft DSM to access LUNs on SC Series arrays in order to ensure proper behavior and performance. This includes hosts configured to use single-path and MPIO. Note: Using mixed transports concurrently on the same Windows Server host is not supported with Server 2012 R2 and newer. With Windows Server 2012 R2 and newer, when a LUN is presented to the host that is using multiple transports such as Fibre Channel and iscsi, the host will default to one transport or the other (typically Fibre Channel is chosen by the host over iscsi) and ignore the other transport. When configured to use multiple transports, if all paths for one type of transport go down, the host may not send data using the other transport without a disk re-scan. This is default Windows Server behavior. 45 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
46 A.1 Recommended updates and hotfixes for Windows Server 2008 R2 SP1 Recommended updates and hotfixes for Windows Server 2008 R2 SP1 KB number Title Link KB Convenience rollup update for Windows 7 SP1 and Windows Server 2008 R2 SP1 (mpio.sys, msdsm.sys, storport.sys, msiscsi.sys 3/25/16) A.2 Recommended updates and hotfixes for Windows Server 2012 (non-r2 version) Recommended updates and hotfixes for Windows Server 2012 (non-r2 version) KB number Title Link KB KB KB KB Windows-based MSDSM doesn t handle sense code 02/04/03 (LUN Not Ready Manual Intervention Required) (mpio.sys 9/24/2014) No host bus adapter is present error when querying SAS cable issues in Windows Server 2012 R2 or Windows Server 2012 (storport.sys 11/19/2014) Server may freeze during startup when ALUAcapable storage is used in Windows Server 2012 R2 or Windows Server 2012 (msdsm.sys - 5/6/2015) Data is corrupted after iscsi sessions or paths recover in Windows Server 2012 R2 or Windows Server 2012 (msiscsi.sys 11/9/2015) Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
47 A.3 Recommended updates and hotfixes for Windows Server 2012 R2 Recommended updates and hotfixes for Windows Server 2012 R2 KB Number Title Link KB KB KB KB System fails back to a host copy instead of an array copy or storages go down after LUN reset in Windows Server 2012 R2 (msdsm.sys 1/24/2016) October 2016 Preview of Monthly Quality Rollup for Windows 8.1 and Windows Server 2012 R2 (msiscsi.sys 9/9/2016) "0x000000D1" Stop error with update rollups on Windows Server 2012 R2 (mpio.sys 12/9/2016) iscsi disks are lost on upgrade for StorSimple appliances after update is installed on Windows Server 2012 R2 (storport.sys 12/9/2016) A.4 Recommended updates and hotfixes for Windows Server 2016 Microsoft publishes updates for Windows Server 2016 cumulatively. Any updates for storage-related files are included in the cumulative updates. Recommended updates and hotfixes for Windows Server 2016 KB Number Title Link KB Cumulative Update for Windows Server 2016 for x64-based Systems May 2017 (mpio.sys 4/27/2017, storport.sys 3/4/2017, msiscsi.sys 3/28/2017) 47 Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
48 A.5 Recommended registry settings for Windows Server The recommend registry settings listed in this section can be applied using the registry editor (regedit.exe) or through PowerShell. The registry editor can be used on all versions of Windows Server Desktop (Server with a GUI). PowerShell is the only option available to change registry settings on Nano Server, but can also be used on all versions of Windows Server Desktop. Refer to section A.7 for a PowerShell script that will apply recommended registry settings to all versions of Windows Server and Nano Server. Note: Recommended registry settings apply to all versions of Windows Server unless directly specified. Setting name Recommended registry settings location: HKLM\SYSTEM\CurrentControlSet\Services\mpio\Parameters Description Default value Recommended value PDORemovePeriod PathRecoveryInterval This setting controls the number of seconds that the multipath pseudo-lun remains in system memory, even after losing all paths to the device. When this timer value is exceeded, pending I/O operations will be failed, and the failure is exposed to the application rather than attempting to continue to recover active paths. The maximum time allowed is MAXULONG (49,000 days). Represents the period after which PathRecovery is attempted. This setting is only used if it is not set to 0 and UseCustomPathRecoveryInterval is set to UseCustomPathRecoveryInterval If this key exists and is set to 1, it allows the use of PathRecoveryInterval. 0 1 PathVerifyEnabled This flag enables path verification by MPIO on all paths every N seconds (where N depends on the value set in PathVerificationPeriod). This Boolean function must be filled with either 0 (disable) or 1 (enable). By default, it is disabled Dell EMC SC Series Storage: Microsoft Multipath I/O CML1004
Dell EMC SC Series Storage and Microsoft Multipath I/O
Dell EMC SC Series Storage and Microsoft Multipath I/O Abstract This document provides an overview of Multipath I/O (MPIO) along with best practice guidelines for configuring MPIO on Microsoft Windows
More informationDell EMC Unity Family
Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July
More informationDell EMC SC Series Storage with SAS Front-end Support for VMware vsphere
Dell EMC SC Series Storage with SAS Front-end Support for VMware vsphere Abstract This document describes how to configure VMware vsphere hosts equipped with supported SAS HBAs to access SAN storage on
More informationData Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import
Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import Abstract The Thin Import feature of Dell Storage Center Operating System offers solutions for data migration
More informationWindows Host Utilities Installation and Setup Guide
IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that
More information3.1. Storage. Direct Attached Storage (DAS)
3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that
More informationConfiguring Multipath-IO for Windows Server 2012/2012R2/2016
Configuring Multipath-IO for Windows Server 2012/2012R2/2016 Overview There are three Windows Server management tasks that need to be completed for the Pure Storage FlashArray volumes (LUNs) to work properly.
More informationDell Storage Center OS Version 7 Software Update Guide
Dell Storage Center OS Version 7 Software Update Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationBoot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)
Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017
More informationDeploying Microsoft Exchange Server 2016 on Dell EMC XC Series using iscsi
Deploying Microsoft Exchange Server 2016 on Dell EMC XC Series using iscsi A fully supported, scalable, hyper-converged compute and storage solution for Microsoft Exchange Server 2016 deployment Dell EMC
More informationDeploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020
Deploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020 Deployment guide with step-by-step instructions Abstract This
More informationDell Compellent Storage Center
Dell Compellent Storage Center How to Setup a Microsoft Windows Server 2012 Failover Cluster Reference Guide Dell Compellent Technical Solutions Group January 2013 THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL
More informationDeploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020
Deploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020 Deployment guide with step-by-step instructions Abstract This
More informationCitrix XenServer with Dell SC Series Storage Configuration and Deployment
Citrix XenServer with Dell SC Series Storage Configuration and Deployment Dell Storage Engineering January 2017 A Dell EMC Deployment and Configuration Guide Revisions Date January 2016 Description Initial
More informationREDUXIO BEST PRACTICES
REDUXIO BEST PRACTICES FOR WINDOWS SERVERS For more information, refer to Reduxio Systems Inc. website at http://www.reduxio.com. If you have comments about this documentation, submit your feedback to
More informationDell EMC SAN Storage with Video Management Systems
Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for
More informationMIGRATING TO DELL EMC UNITY WITH SAN COPY
MIGRATING TO DELL EMC UNITY WITH SAN COPY ABSTRACT This white paper explains how to migrate Block data from a CLARiiON CX or VNX Series system to Dell EMC Unity. This paper outlines how to use Dell EMC
More informationDataONTAPDSM3.5forWindows MPIO Release Notes
IBM System Storage N series DataONTAPDSM3.5forWindows MPIO Release Notes GC27-2054-14 Contents Data ONTAP DSM 3.5 for Windows MPIO Release Notes............... 1 Updates to the release notes.........................
More informationDell EMC SC Series Storage and SMI-S Integration with Microsoft SCVMM
Dell EMC SC Series Storage and SMI-S Integration with Microsoft SCVMM Dell EMC Engineering February 2017 A Dell EMC Deployment and Configuration Guide Revisions Date May 2012 February 2013 December 2013
More informationDEE DECE-IE SC Series. A Success Guide to Prepare- Dell EMC Expert - SC Series. edusum.com
DEE-1721 DECE-IE SC Series A Success Guide to Prepare- Dell EMC Expert - SC Series edusum.com Table of Contents Introduction to DEE-1721 Exam on Dell EMC Expert - SC Series... 2 Dell EMC DEE-1721 Certification
More informationDell Compellent Storage Center. XenServer 6.x Best Practices
Dell Compellent Storage Center XenServer 6.x Best Practices Page 2 Document revision Date Revision Description 2/16/2009 1 Initial 5.0 Documentation 5/21/2009 2 Documentation update for 5.5 10/1/2010 3
More informationWindows Unified Host Utilities 7.0 Installation Guide
Windows Unified Host Utilities 7.0 Installation Guide February 2017 215-09443_C0 doccomments@netapp.com Table of Contents 3 Contents Introduction to Host Utilities... 5 What the Host Utilities are...
More informationEMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA
EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.
More informationDeploying the 200TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000
Deploying the 200TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000 Deployment guide with step-by-step instructions Abstract This
More informationCOPYRIGHTED MATERIAL. Windows Server 2008 Storage Services. Chapter. in this chapter:
Chapter 1 Windows Server 2008 Storage Services Microsoft Exam Objectives covered in this chapter: ÛÛConfigure storage. May include but is not limited to: RAID types, Virtual Disk Specification (VDS) API,
More informationEMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05
EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006
More informationDeploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020
Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Dell Storage Engineering December 2015 A Dell Deployment and
More informationConfiguring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center
Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Dell Compellent Solution Guide Kris Piepho, Microsoft Product Specialist October, 2013 Revisions Date Description 1/4/2013
More informationiscsi Boot from SAN with Dell PS Series
iscsi Boot from SAN with Dell PS Series For Dell PowerEdge 13th generation servers Dell Storage Engineering September 2016 A Dell Best Practices Guide Revisions Date November 2012 September 2016 Description
More informationDell EMC SC Series Storage and Microsoft Windows Server 2016
Dell EMC SC Series Storage and Microsoft Windows Server 2016 Abstract This document provides best practices for configuring Microsoft Windows Server 2016 hosts with Dell EMC SC Series SAN arrays. November
More informationWindows Unified Host Utilities 7.1 Installation Guide
Windows Unified Host Utilities 7.1 Installation Guide January 2018 215-12499_B0 doccomments@netapp.com Table of Contents 3 Contents Introduction to Host Utilities... 5 What the Host Utilities are... 5
More informationDell EMC SC Series and Active Directory Integration
Dell EMC SC Series and Active Directory Integration Dell EMC Engineering December 2017 A Dell EMC Best Practices Guide Revisions Date January 2013 January 2017 December 2017 Description Initial release
More informationStarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016
One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind
More informationWeb Console Setup & User Guide. Version 7.1
Web Console Setup & User Guide Version 7.1 1 Contents Page Number Chapter 1 - Installation and Access 3 Server Setup Client Setup Windows Client Setup Mac Client Setup Linux Client Setup Interoperation
More informationSurveillance Dell EMC Storage with FLIR Latitude
Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information
More informationTHE FOLLOWING EXAM OBJECTIVES ARE COVERED IN THIS CHAPTER: Configure local storage. Configure Windows Firewall
Chapter 17 Configuring File and Storage Services THE FOLLOWING 70-410 EXAM OBJECTIVES ARE COVERED IN THIS CHAPTER: Configure local storage This objective may include, but is not limited to: Design storage
More informationEMC SAN Copy Command Line Interfaces
EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All
More informationStarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018
One Stop Virtualization Shop StarWind Virtual SAN HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2 MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the
More informationConfiguring and Managing Virtual Storage
Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks
More informationDELL TM PowerVault TM DL Backup-to-Disk Appliance
DELL TM PowerVault TM DL Backup-to-Disk Appliance Powered by Symantec TM Backup Exec TM Configuring the Dell EqualLogic PS Series Array as a Backup Target A Dell Technical White Paper by Dell Engineering
More informationCisco UCS Virtual Interface Card Drivers for Windows Installation Guide
Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide First Published: 2011-09-06 Last Modified: 2015-09-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA
More informationStarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN of HyperConverged 2 Nodes with Hyper-V Cluster AUGUST 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and
More informationDELL EMC UNITY: HIGH AVAILABILITY
DELL EMC UNITY: HIGH AVAILABILITY A Detailed Review ABSTRACT This white paper discusses the high availability features on Dell EMC Unity purposebuilt solution. October, 2017 1 WHITE PAPER The information
More informationPS Series Best Practices Deploying Microsoft Windows Clustering with an iscsi SAN
PS Series Best Practices Deploying Microsoft Windows Clustering with an iscsi SAN Abstract This Technical Report describes how to use PS Series storage arrays with a Microsoft Windows Server 2003 cluster.
More informationPowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules
PowerEdge FX - Upgrading from 0GbE Pass-through Modules to FN40S I/O Modules Dell Networking Solutions Engineering June 06 A Dell EMC Deployment and Configuration Guide Revisions Date Revision Description
More informationStarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016
One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind
More informationDell EMC Unity Family
Dell EMC Unity Family Version 4.4 Configuring and managing LUNs H16814 02 Copyright 2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes the information in this publication
More informationStarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2
One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 DECEMBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software
More informationVERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path
White Paper VERITAS Storage Foundation for Windows VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path 12/6/2004 1 Introduction...3 Dynamic MultiPathing (DMP)...3
More informationDataONTAPDSM4.0.1forWindows MPIO Installation and Administration Guide
IBM System Storage N series DataONTAPDSM4.0.1forWindows MPIO Installation and Administration Guide GC27-2053-08 Table of Contents 3 Contents Preface... 8 Supported features... 8 Websites... 8 Getting
More informationVideo Surveillance EMC Storage with Godrej IQ Vision Ultimate
Video Surveillance EMC Storage with Godrej IQ Vision Ultimate Sizing Guide H15052 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published May 2016 EMC believes the information
More informationData ONTAP DSM 4.1 for Windows MPIO Installation and Administration Guide
Data ONTAP DSM 4.1 for Windows MPIO Installation and Administration Guide January 2018 215-08396_B0 doccomments@netapp.com Table of Contents 3 Contents DSM concepts... 7 Device-specific module overview...
More informationThe Host Server. Microsoft Windows Configuration Guide. February The Data Infrastructure Software Company
The Host Server Microsoft Windows Configuration Guide February 2018 This guide provides configuration settings and considerations for SANsymphony Hosts running Microsoft Windows. Basic Microsoft Windows
More informationStarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016
One Stop Virtualization Shop Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind
More informationSetup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5
Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Setup for Microsoft Cluster Service Revision: 041108
More informationStarWind Virtual SAN AWS EC2 Deployment Guide
One Stop Virtualization Shop StarWind Virtual SAN AUGUST 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind
More informationThe Host Server. Microsoft Windows Configuration Guide. September The Data Infrastructure Software Company
The Host Server Microsoft Windows Configuration Guide September 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running Microsoft Windows. Basic Microsoft Windows
More informationCompellent Storage Center
How To Setup a Microsoft Windows Server 2003 Failover Cluster Compellent Corporate Office Compellent Technologies 7625 Smetana Lane Eden Prairie, Minnesota 55344 www.compellent.com Contents Contents...
More informationDell Networking S5000: Deployment of a Converged Infrastructure with FCoE. Deployment/Configuration Guide
Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE Dell Technical Marketing Data Center Networking June 2013 This document is for informational purposes only and may contain typographical
More informationStarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop
One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind
More informationFUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed
More informationWHITE PAPER: ENTERPRISE SOLUTIONS. Veritas Storage Foundation for Windows Dynamic Multi-pathing Option. Competitive Comparisons
WHITE PAPER: ENTERPRISE SOLUTIONS Veritas Storage Foundation for Windows Competitive Comparisons White Paper: Enterprise Solutions Veritas Storage Foundation for Windows Contents Introduction........................................................................4
More informationBest Practices for Sharing an iscsi SAN Infrastructure with Dell PS Series and SC Series Storage using VMware vsphere Hosts
Best Practices for Sharing an iscsi SAN Infrastructure with Dell PS Series and SC Series Storage using VMware vsphere Hosts Dell Storage Engineering January 2017 Dell EMC Best Practices Revisions Date
More informationTerminology. This document uses the following terms:
CX4 Architecture for NS Series Connecting a CX4-48 Storage System in a Fibre Channel Direct or Switch Configuration with a Microsoft Windows Server with Native Multipath Failover December 6, 28 If you
More informationA Principled Technologies deployment guide commissioned by QLogic Corporation
A Principled Technologies deployment guide commissioned by QLogic Corporation Table of contents Executive summary... 2 Introduction... 2 QLogic QConvergeConsole... 3 Overview of the procedure... 4 Initial
More informationDell EMC SC Series Arrays and Oracle
Dell EMC SC Series Arrays and Oracle Abstract Best practices, configuration options, and sizing guidelines for Dell EMC SC Series storage in Fibre Channel environments when deploying Oracle. July 2017
More informationWindows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage
Windows Unified Host Utilities 7.0 Using Windows Hosts with ONTAP Storage March 2017 215-09444_B0 doccomments@netapp.com Table of Contents 3 Contents Preparing to use Windows hosts with ONTAP storage...
More informationStarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016
One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and
More informationStarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2
One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the
More informationHow to Configure NPIV in a Microsoft Hyper-V Environment
How to Configure NPIV in a Microsoft Hyper-V Environment Designed for Windows System Administrators and Storage Administrators, this document provides guidelines for configuring Microsoft Hyper-V using
More informationStarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016
One Stop Virtualization Shop StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind
More informationSetup for Failover Clustering and Microsoft Cluster Service
Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the
More informationDell PowerVault MD3460 Series Storage Arrays Deployment Guide
Dell PowerVault MD3460 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION
More informationPreparing the boot media/installer with the ISO file:
Preparing the boot media/installer with the ISO file: Download and extract the ISO file with your favorite uncompressing/extracting software (for example: 7zip or WinZip programs) to an empty USB Flash
More informationStarWind Virtual SAN Compute and Storage Separated with Windows Server 2016
One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind
More informationHP Supporting the HP ProLiant Storage Server Product Family.
HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication
More informationStarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V.
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. MARCH 2015 TECHNICAL PAPER Trademarks StarWind,
More informationNetApp Deployment Guidelines and Storage Best Practices for Windows Server 2016
Technical Report NetApp Deployment Guidelines and Storage Best Practices for Best Practice Guide Brahmanna Chowdary Kodavali and Shashanka SR, NetApp November 2016 TR-4568 Abstract This technical report
More informationHYPER-UNIFIED STORAGE. Nexsan Unity
HYPER-UNIFIED STORAGE Nexsan Unity Multipathing Best Practices Guide NEXSAN 25 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 9160 USA Printed Wednesday, January 02, 2019 www.nexsan.com Copyright 2010
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : DSDSC-200 Title : Dell SC Series Storage Professional Exam Vendor : Dell Version : DEMO Get Latest &
More informationDell EMC PowerVault MD3860f Series Storage Arrays. Deployment Guide
Dell EMC PowerVault MD3860f Series Storage Arrays Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A
More informationVendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo
Vendor: EMC Exam Code: E20-002 Exam Name: Cloud Infrastructure and Services Exam Version: Demo QUESTION NO: 1 In which Cloud deployment model would an organization see operational expenditures grow in
More informationHS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.
HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. Martin Gingras Product Field Engineer, Canada mgingras@ca.ibm.com Acknowledgements Thank you to the many people who have contributed and reviewed
More informationEMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V
IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on
More informationDELL EMC UNITY: REPLICATION TECHNOLOGIES
DELL EMC UNITY: REPLICATION TECHNOLOGIES A Detailed Review ABSTRACT This white paper explains the replication solutions for Dell EMC Unity systems. This paper outlines the native and non-native options
More informationDell EMC SCv3020 7,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K drives
Dell EMC SCv3020 7,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K drives Microsoft ESRP 4.0 Abstract This document describes the Dell EMC SCv3020 storage solution for Microsoft Exchange
More informationDELL TM PowerVault TM DL Backup-to-Disk Appliance
DELL TM PowerVault TM DL Backup-to-Disk Appliance Powered by CommVault TM Simpana TM Configuring the Dell EqualLogic PS Series Array as a Backup Target A Dell Technical White Paper by Dell Engineering
More informationLenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group)
Lenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group) First Edition (December 2016) Copyright Lenovo 2016. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software
More informationA3800 & A3600. Service Release SR2.1 Release Notes. A-Class. VTrak A-Class firmware version Clients
VTrak A-Class A3800 & A3600 Service Release SR2.1 Release Notes A-Class VTrak A-Class firmware version 1.11.0000.00 Clients VTrak Mac Client Package 1.3.1 42009 VTrak Windows Client Package 1.3.0-40692
More informationVMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY
VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY HYPERMAX OS Integration with CloudArray ABSTRACT With organizations around the world facing compliance regulations, an increase in data, and a decrease in IT spending,
More informationSAN Configuration Guide
ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi
More informationStep-by-Step Guide to Installing Cluster Service
Page 1 of 23 TechNet Home > Products & Technologies > Windows 2000 Server > Deploy > Configure Specific Features Step-by-Step Guide to Installing Cluster Service Topics on this Page Introduction Checklists
More informationEMC VMAX ALL FLASH AND VMAX3 iscsi DEPLOYMENT GUIDE FOR WINDOWS ENVIRONMENTS
EMC VMAX ALL FLASH AND VMAX3 iscsi DEPLOYMENT GUIDE FOR WINDOWS ENVIRONMENTS EMC VMAX Engineering White Paper ABSTRACT This white paper provides guidelines and best practices for deploying iscsi with EMC
More informationBest Practices for Sharing an iscsi SAN Infrastructure with PS Series and SC Series using Windows Hosts
Best Practices for Sharing an iscsi SAN Infrastructure with PS Series and SC Series using Windows Hosts Dell EMC Engineering April 2017 Dell EMC Best Practices Revisions Date March 2015 April 2015 December
More informationEMC SourceOne Discovery Manager Version 6.7
EMC SourceOne Discovery Manager Version 6.7 Installation and Administration Guide 300-012-743 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
More informationDSI Optimized Backup & Deduplication for VTL Installation & User Guide
DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:
More informationHP StoreVirtual DSM for Microsoft MPIO Deployment Guide
HP StoreVirtual DSM for Microsoft MPIO Deployment Guide HP Part Number: AX696-96344 Published: December 2013 Edition: 5 Copyright 2011, 2013 Hewlett-Packard Development Company, L.P. Revision History Revision
More informationEMC CLARiiON Asymmetric Active/Active Feature (ALUA)
A Detailed Review Abstract This white paper provides an overview of the EMC CLARiiON Asymmetric Active/Active feature. It highlights the configuration, best practices, implementation details of EMC PowerPath,
More information