SFT Installation Use. SFT Installation - Use A - D 1

Size: px
Start display at page:

Download "SFT Installation Use. SFT Installation - Use A - D 1"

Transcription

1 SFT 2801 Installation Use SFT Installation - Use A - D 1

2 contents introduction 3 ACE 900 connection kit 4 graphical interface 5 user guide 7 reading characteristics 12 operations on characteristics Erreur! Signet non défini.5 disturbance records 18 application identification 1 printing 1 installing SFT appendix 1 SFT 2801 keys / keyboard equivalencies 28 appendix 2 example of Sepam 2000 parameter readout 29 SFT Installation - Use A - D 2

3 introduction description The SFT 2801 application is a software tool that may be used instead of the "TSM 2001 pocket terminal" under Windows 95, 98 and NT 4.0. Furthermore, the SFT 2801 application provides additional functions for reading, printing and storage of Sepam 2000 parameters and for retrieving disturbance records. It is installed on a PC connected to the front of Sepam 2000 via an adapter. functions All the TSM 2001 pocket terminal functions are included in the SFT 2801 application. The functions used to read and set the various Sepam 2000 parameters (measurements, protections, etc.) in the software version of TSM 2001 are similar to the pocket terminal functions (dialog via menus and submenus; cf manual ref ). The following additional functions are made available by the software version : general readout of Sepam 2000 characteristics. saving and restoring of all Sepam 2000 characteristics. printing of a report containing the values of all the Sepam 2000 characteristics. retrieval of a disturbance record saving of a disturbance record required set-up The minimum set-up is given in the installation section. SFT Installation - Use A - D 3

4 ACE 900 connection kit kit contents connection The ACE 900 connection kit supplied with SFT 2801 is made up of : 1 Sepam - RS232 interface 1 PC - interface serial connection cord The interface should be plugged into the inlet on the front of Sepam 2000, behind the small flap door. The other end is connected to the COM1 or COM2 communication port (whichever was selected at the time of installation) on the PC. front of Sepam interface should be plugged into the inlet It is mandatory for the ACE 900 connection kit supplied in SFT 2801 kit to be used to connect the PC and Sepam The use of any other cord is liable to cause Sepam 2000 operating difficulties. environmental specifications dielectric dielectric withstand IEC /5 0.5kVeff CM 1.2/50µs impulse wave IEC /5 1kV MC, 0.5kV DM climatic operation IEC to 55 C storage IEC to 70 C electromagnetic radiation IEC V/m IEC V/m electrostatic discharge IEC kV 1MHz damped oscillating IEC kV MC, 0.5kV DM wave 5ns fast transient IEC kV CM, DM direct coupling 4kV CM capacitive coupling CM = common mode DM = differential mode SFT Installation - Use A - D 4

5 graphical interface design The SFT 2801 application is materialized in Windows by a graphical interface (window) representing the TSM 2001 pocket terminal. A B C D A the title bar displays the name of the application: "SFT 2801" followed by identification of the Sepam when a Sepam is connected to the PC. B the menu bar gives access to the SFT 2801 special features C the display field may be one of two types : an SFT 2801 information screen an TSM 2001 type screen, with four 20-character lines. D control buttons which match the TSM 2001 pocket terminal keyboard keys display zone SFT 2801 keyboard The software version display is the same as the TSM 2001 pocket terminal display: four 20-character lines. The same blinking also occurs. The cursor at the beginning of a line is indicated by a blinking ">" character. Pressing a key on the SFT 2801 keyboard may be reproduced in two ways : using the mouse, by clicking on the corresponding button. SFT Installation - Use A - D 5

6 graphical interface using the PC keyboard, by pressing the corresponding key. The key is generally identified by the name which appears on the control button on the SFT 2801 keyboard (cf Appendix 1). behaviour The SFT 2801 application complies with the usual MS-Windows rules and operating procedures, which are not reminded here. In case of necessity, please refer to the manuals supplied with your computer. SFT Installation - Use A - D 6

7 user guide starting up the application In the Windows Program Manager, double-click on the SFT 2801 icon. The window below appears in the centre of the screen. When pressing Enter, the following warning window is displayed. SFT Installation - Use A - D 7

8 user guide When this message is acknowledged, the SFT 2801 main window is displayed. PC/Sepam dialog is not activated until communication has been initialized. SFT Installation - Use A - D 8

9 user guide customization of application This function allows to customize the program language and the serial I/O port of computer connected to Sepam. To change the language, select Customization then Languages. Select then the new language. To change the I/O port, select Customization then PC port name. Select then the new port. SFT Installation - Use A - D 9

10 user guide initializing communication To initialize communication between the PC and Sepam, click on the keyboard. control button or press function key F5 on the PC Although the window is displayed, it remains inactive for 5 to 10 seconds, during which time no action is possible. The application needs this time to test the Sepam to obtain its identifier. The window becomes active when the reading of Sepam identification has been completed : the title bar then displays the identifier of the Sepam connected to the PC in addition to the application name. The "Identifying" message disappears from the display field, giving way to the usual Sepam opening menu. In this status, the user may use the software version of TSM 2001 in exactly the same way as the pocket terminal. SFT Installation - Use A - D 10

11 user guide scanning Sepam As of the time that communication is initialized, SFT 2801 continually scans the link with the Sepam connected to the PC on which the application is running. If the Sepam connection is down (connection cord damaged or Sepam disconnected or not energized...), SFT 2801 detects interrupted dialog and displays : The graphical interface is inactive until the user validates the message window by clicking on the "OK" button. Communication must then be initialized again. SFT Installation - Use A - D 11

12 reading characteristics description activate This function is a general readout of Sepam characteristics. It works by reading the following Sepam parameters : Sepam identification and software versions ("About Sepam" choice). Sepam settings ("Status" choice). Protection settings ("Protections" choice). Parameters ("Program logic" and "Parameters" choice). Timers ("Program logic" and "Timer") choice. To activate reading of all the characteristics, select the Charact. Then Read item in the SFT 2801 menu bar. The SFT 2801 graphical interface becomes inactive and the following message is displayed : The Sepam characteristics reading operation takes about 2 to 6 minutes, depending on the Sepam configuration. The operation may be interrupted at any time by clicking on the "Cancel" button or by pressing the "Return" key on the PC keyboard. When the operation is interrupted, the SFT 2801 window becomes active again, the dialog between the PC and Sepam is reinitialized and the Sepam opening menu appears again in the display field. SFT Installation - Use A - D 12

13 reading characteristics view If the characteristics reading operation is successfully completed, a full screen size characteristics display window appears. A slider bar (scroll bar) located on the right-hand side of the display field may be used to scroll its contents vertically. The window also includes 3 control buttons : record To save the characteristics that have been read, click on the "Record" control button. A dialog box is then displayed. This box is used to choose a name to identify the characteristics that will be saved. The name of the Sepam being examined is proposed (the name appears in the title bar of the main screen and the characteristics display window). When several Sepams have the same name (as in the case of the standard applicationsof the Sepam 2000 catalogue), it is necessary to modify the proposed name to record and save the characteristics of the Sepams which have the same name. SFT Installation - Use A - D 13

14 reading characteristics Once the user has confirmed the name to be used for the save, the text of the displayed characteristics is stored on the PC disk and may be retrieved for subsequent printing or saving operations. If several storage operations are carried out for the same Sepam, only the most recent one is kept. The date of storage of the characteristics is memorized. The data structure used is a text file, the contents of which are an exact replica of the text displayed in the display window (cf example in Appendix 2). The name given for the stored data will appear on the first page of the printout of characteristics under the heading "Sepam Name". The actual name of the Sepam application is given in the "Identification" section by the text located under the name "SFT 2800". print To print the characteristics that have been read, click the "Print" control button. This command is only available after the user has stored the characteristics. The printing format is virtually the same as the display and storage formats. It also includes a cover page giving identification of the Sepam and the setting dates. Refer to the "print" chapter for more information on printing. cancel To close the characteristics display window, click on the "Cancel" control button or double-click on the system menu box. The SFT 2801 window then takes over again and the Sepam opening menu appears again in the display field. SFT Installation - Use A - D 14

15 operations on characteristics The Charact. item in the SFT 2801 menu bar gives access to various functions operating on the previously saved characteristics. print This option may be used to print Sepam characteristics that have been previously recorded from the characteristics display window (cf chapter entitled "reading characteristics"). The print window appears in the centre of the screen, which lists the previously recorded Sepams. Select the Sepam that you want to print and click on the "Validate" button to start printing. A "Cancel" button may be used to return to the SFT 2801 graphical interface without printing. Refer to the chapter entitled "Printing" for more information on the printing procedure. save Sepam saving enables the user to transfer the information regarding the parameters of one or more Sepams, previously stored using the "Record" command (Cf "reading characteristics" chapt.), to any backup medium recognized by Windows (diskette or other).the save window is displayed in the centre of the screen. SFT Installation - Use A - D 15

16 operations on characteristics in the "From" field, select each of the Sepams that you wish to save. in the "To" field, select the destination medium and/or directory. If the desired directory is not found, you must create it. A list displays the Sepams that have already been saved in the selected backup directory (indicated in the "Directory" string), with the save dates. click on the "Validate" button to start the save operation. The "Cancel" button may be used to return to the SFT 2801 graphical interface without saving. restore Sepam restoring enables the user to transfer the information related to the parameters of one or more Sepams from a backup medium to the SFT The restore window is displayed in the centre of the screen. in the "From" field, select the restore source medium and/or directory, and then the Sepams to be restored (the current path to the source medium is indicated in the "Directory" string). SFT Installation - Use A - D 16

17 operations on characteristics in the "To" field, a list indicates the Sepams already included in the SFT click on the "Validate" button to begin restoring. The "Cancel" button may be used to return to the SFT 2801 graphical interface without restoring. delete This option is used to delete previously recorded information related to the characteristics of one or more Sepams, when that information is no longer of any use. The delete window appears in the centre of the screen. select the Sepams that you wish to delete, in the list of previously recorded Sepams. click on the "Validate" button to delete the characteristics of the selected Sepams. The "Cancel" button may be used to return to the SFT 2801 graphical interface. SFT Installation - Use A - D 17

18 disturbance records The Disturb. item in the SFT 2801 menu bar gives access to various functions operating on disturbance records. recover This choice is used to retrieve a disturbance record from the Sepam. The following window appears, which lists the available records : select the record that you want to read type in the name to identify the record that will be retrieved click on the "Validate" button to start reading The "Cancel" button may be used to return to the SFT 2801 graphical interface without reading. The SFT 2801 graphical interface becomes inactive and the following message is displayed : The disturbance record reading operation takes about 3 minutes. The operation may be interrupted at any time by clicking on the "Cancel" button or by pressing the "Return" key on the PC keyboard. When the operation is completed (or cancelled), the SFT 2801 window becomes active again, the dialog between the PC and Sepam is reinitialized and the Sepam opening menu appears again in the display field. SFT Installation - Use A - D 18

19 disturbance records save delete SFT 2826 This option may be used to transfer the previously retrieved disturbance record to any backup medium recognized by MS-DOS (diskette or other). It works the same way as the save option for Sepam characteristics. Please refer to the corresponding chapter. This option is used to delete previously retrieved disturbance records, when they are no longer of any use.it works the same way as the delete option for Sepam characteristics. Please refer to the corresponding chapter. To display the retrieved disturbance records, you may use the SFT 2826 application (or any COMTRADE compliant application). The disturbance record files are placed in the "\REG2000" subdirectory of the directory in which the SFT 2801 application has been installed. SFT Installation - Use A - D 19

20 application identification SFT 2801 software version When you select the? then About... option in the SFT 2801 menu bar, a window giving various items of information on the SFT 2801 software package is displayed. SFT Installation - Use A - D 20

21 printing introduction print Before printing, you must first check that Windows is set up correctly for the type of printing device to which your work station is connected. For further information, refer to the Windows User's Guide. Printing of Sepam characteristics is accessed from the parameter display window (Cf chapter entitled "reading parameters") or via the Print option in the Charact. menu bar item. The printed file is sent to the Windwos printer manager. error messages Different types of errors may occur during printing. In such a case, a message displays the type of error encountered, and printing is automatically interrupted. The main types of errors are the following : a general error related to the printer (printer not connected or not set up correctly, out of paper...). impossible to use printer. This error occurs when the print driver or output port, chosen via the Windows control panel, is incorrect. Refer to the Windows manual. out of disk space: temporary files are created by Windows, and the current disk unit must have sufficient space available for those files. SFT Installation - Use A - D 21

22 installing SFT 2801 general information The program is very simple to use and does not require any prior knowledge of your computer or computer technology. The program allows to install together or separately the SFT 2801 and SFT 2821 software. set-up The installation diskettes are common for these products. The minimum hardware set-up required to run the SFT2821 software is as follows: PC compatible microcomputer: Pentium type 133 MHz 32 Mb Ram (minimum) graphic display (EGA, VGA, Super VGA), minimum resolution 800 by 600 pixels, a 3"½ diskette drive (1.44 Mb) a hard disk (4 Mb available) an available RS232 communication port (COM1 or COM2) system: a printer (optional) starting the installation Windows 95 (version 708 or later version) or Windows 98 or Windows NT 4.0 version 1382 with pack 3 or later version and rights to modify Window NT system files. Insert diskette N 1 of the installation package in your disk drive. In the menu Start select Settings and then Control Panel. Select the Add/Remove Programs function. Click on the Install button in the form Install/Uninstall Follows the instruction from Windows to install the program from the installation diskette. SFT Installation - Use A - D 22

23 installing SFT 2801 installation start-up A start-up program will copy the files needed to run the SFT2801/SFT2821 installation program. It s important that all the Windows applications are closed during the installation process to avoid access conflicts to system files. By the way, if a conflict occurs, a message will appear. In this case Close all the applications and restart the installation. If the conflict is still present, then select the Ignore button on the window and continue the installation. It s also possible that the installaton requires the reboot of your system for the upgraded system files to be taken into account. In this case, perform the reboot and restart the installation from the beginning. canceling during installation It is possible to cancel the installation procedure at any time, in which case everything that has been created by the program (files, directory, icons, shortcuts, ) up to the cancellation is automatically deleted. SFT Installation - Use A - D 23

24 installing SFT 2801 start-up screen First of all, the screen asks the user to close the applications before continuing the installation of the SFT2801 software. In this case, the user chooses "Exit installation". The installation procedure must be started over from the beginning. choosing the installation directory In addition, the screen may be used to choose the installation language, which will also be the default language of the SFT 2801 program. he following screen is used to select the installation directory. The directory proposed by default is c:\program Files\Schneider\. T The SFT2801 is installed in a SFT2801 directory which is created in this directory by default. With the "Change directory" button, it is possible to choose another default directory in which the SFT2801 directory will be created. If the default directory does not exist, it is created. SFT Installation - Use A - D 24

25 installing SFT 2801 choosing the program to be installed SFT2801 and SFT2821 may be installed at the same time or separately. If the SFT2821 software is selected as well, it is installed in the directory chosen in the previous screen, in an SFT2821 subdirectory. checking disk space At this stage of the installation, the software checks that the computer has enough disk space for the selected software to be installed. SFT Installation - Use A - D 25

26 installing SFT 2801 choosing the group of programs This screen is sued to choose the group of programs that will be created in the Start / Programs menu. The choice proposed by default is Schneider. According to the programs selected for the installation, one or two icons SFT2801 and SFT2821 are created in the new group. copying files The program copies the files required for the chosen program or programs. SFT Installation - Use A - D 26

27 installing SFT 2801 The application may propose you to keep a file which is more recent on your disk than the version on diskette. In this case, it s recommended that you keep your existing file. In particular the SFT2801.INI file which contents the personalized settings of your program. end of installation Deinstallation The system files are then updated. The program icons are created. A message informs you that the software has been installed correctly. Before deinstalling the software, the user should check that the SFT2801 software is not running. To deinstall: in the Start menu, choose Settings and then Control Panel, click on Add /Delete program, go to the Install /Deinstall tab, select the software in the list to be deinstalled, click on add/delete, confirm deinstallation. Windows can only deinstall files that have been installed using the installation software. If you want the deinstallation tool to actually delete all the directories in the software, before starting deinstallation, you must manually delete all the files contained in SFT2801\reg2000 for the SFT2801 program. SFT Installation - Use A - D 27

28 appendix 1 SFT 2801 keys / keyboard equivalencies SFT 2801 keys PC keyboard F1 function key UP arrow key DOWN arrow key "9" number key "8" number key "7" number key "6" number key "5" number key "4" number key "3" number key "2" number key "1" number key "0" number key "." decimal point key F2 function key F3 function key "-" minus key "+" plus key F4 function key return key F5 Initialize F5 function key SFT Installation - Use A - D 28

29 appendix 2 example of Sepam 2000 parameter readout This example gives an idea of the format in which Sepam parameters are displayed, recorded or printed : IDENTIFICATION SFT 2800 : PROGRAM LOGIC : PROGRAM LOGIC VALDEMF ATC : DEPDISJ : program dated : SFT 2800 : : Central switchboard : 94/10/24 15:56 : model : Logipam : STATUS RATED FREQUENCY : PHASE TC RATIO : E/F SENSOR Fn = 50 Hz : In = 90 A : Ino = CT 30A : Ib = 90 A : : Number = I1-I2-I3 : MAX DEMAND INTERV. : VT RATIO : VT RATIO Interval= 10 mn : Number = 3U : Vnso = Uns/1.732 : Unp = 20 kv : : Uns = 100 V : POWER FLOW SENSE : JBUS COMMUNICATION : JBUS COMMUNICATION Type = Incomer : Speed = 9600 bauds : CPT2 = 0 : Address= 1 : CPT9 = 0 : Parity = Even : TIME TAGGING : TIME TAGGING : TIME TAGGING Synchro.=ETOR I21 : KTS 1-8= : KTS25-32= : KTS 9-16= : : KTS17-24= : TIME TAGGING : I1 -I2 = 00 : I11-I18= : I21-I28= : SFT Installation - Use A - D 29

30 appendix 2 example of Sepam 2000 parameter readout PROTECTIONS O/C F011 : O/L F012 : E/F F081 Curve = Definite : Curve = Definite : Curve = Definite Is = 500 A : Is = 600 A : Iso = 60 A T = 500 ms : T = 3 s : T = 1 s U/current F221 : O/V F281 : U/V F341 Is = 80 %Ib : Us = 16 kv : Us = 1.5 kv T = 5 s : T = 3 s : T = 2 s : : brdl F441 : Unbalance F451 : Unbalance F451 Is = 115 %Ib : Curve = Definite : Ii = 0.0 %Ib ST = 8 s : Is = 60 %Ib : LT = 2 s : T = 5 s : ndtf F421 : ndtf F421 : therm F431 N start= 999 : T = 500 ms : OL1 = 105 % H start= 5 : N.rest = 5 : OL2 = 120 % C start= 5 : : K = Average therm F431 : T1 = 5 mn : T2 = 5 mn : E = 0.0 % : SFT Installation - Use A - D 30

31 appendix 2 example of Sepam 2000 parameter readout PARAMETERS KP 1 = 1 KP 2 = 0 KP 3 = 0 KP 4 = 0 KP 5 = 0 KP 6 = 0 KP 7 = 0 KP 8 = 0 KP 9 = 0 KP 10 = 0 KP 11 = 0 KP 12 = 0 KP 13 = 0 KP 14 = 0 KP 15 = 0 KP 16 = 0 TIMERS T1 = 100 ms 0 : T21 = 100 ms 0 : T41 = 100 ms 0 T2 = 100 ms 0 : T22 = 100 ms 0 : T42 = 100 ms 0 T3 = 100 ms 0 : T23 = 200 ms 0 : T43 = 100 ms 0 T4 = 2 s 0 : T24 = 250 ms 0 : T44 = 250 ms 0 T5 = 250 ms 0 : T25 = 250 ms 0 : T45 = 250 ms 0 T6 = 250 ms 0 : T26 = 250 ms 0 : T46 = 250 ms 0 T7 = 1.2 s 0 : T27 = 1.2 s 0 : T47 = 1.2 s 0 T8 = 750 ms 0 : T28 = 1.2 s 0 : T48 = 750 ms 0 T9 = 1.2 s 0 : T29 = 2 s 0 : T49 = 100 ms 0 T10 = 100 ms 0 : T30 = 200 ms 0 : T50 = 200 ms 0 T11 = 200 ms 0 : T33 = 200 ms 0 : T51 = 200 ms 0 T12 = 200 ms 0 : T31 = 200 ms 0 : T52 = 200 ms 0 T13 = 200 ms 0 : T33 = 200 ms 0 : T53 = 200 ms 0 T14 = 200 ms 0 : T34 = 200 ms 0 : T54 = 200 ms 0 T15 = 200 ms 0 : T35 = 200 ms 0 : T55 = 200 ms 0 T16 = 200 ms 0 : T36 = 200 ms 0 : T56 = 200 ms 0 T17 = 200 ms 0 : T37 = 50 ms 0 : T57 = 200 ms 0 T18 = 200 ms 0 : T38 = 200 ms 0 : T58 = 200 ms 0 T19 = 200 ms 0 : T39 = 200 ms 0 : T59 = 200 ms 0 T20 = 200 ms 0 : T40 = 200 ms 0 : T60 = 200 ms 0 SFT Installation - Use A - D 31

SFT2821. Installation. Use. SFT Installation - Use EN-A0 1

SFT2821. Installation. Use. SFT Installation - Use EN-A0 1 SFT2821 Installation Use SFT2821 - Installation - Use 03144389EN-A0 1 contents Introduction 3 ACE 900 connection kit 7 Graphical interface 8 Commissioning 10 Managing setting files 12 Printing 15 Stopping

More information

OPERATING MANUAL. WINDOWS Temperature Controller. Digi -Sense

OPERATING MANUAL. WINDOWS Temperature Controller. Digi -Sense OPERATING MANUAL WINDOWS Temperature Controller Digi -Sense WinTC warranty information and licensing agreement The software and its accompanying documentation and instructions are provided AS IS without

More information

Windows Me Navigating

Windows Me Navigating LAB PROCEDURE 11 Windows Me Navigating OBJECTIVES 1. Explore the Start menu. 2. Start an application. 3. Multi-task between applications. 4. Moving folders and files around. 5. Use Control Panel settings.

More information

NEC Versa 4200 Windows 98 Upgrade Information

NEC Versa 4200 Windows 98 Upgrade Information NEC Versa 4200 Windows 98 Upgrade Information Follow the instructions provided in this document to upgrade your NEC Versa 4200 system to Microsoft Windows 98. Please read these notes in their entirety.

More information

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 www.securakeystore.com (800) 878-7829 sales@securakeystore.com COPYRIGHT 2001

More information

NEC Versa 500D/550D Windows 98 Upgrade Information

NEC Versa 500D/550D Windows 98 Upgrade Information NEC Versa 500D/550D Windows 98 Upgrade Information Follow the instructions provided in this document to upgrade your NEC Versa 500D/550D system to Microsoft Windows 98. Please read these notes in their

More information

Chapter 2: Installation

Chapter 2: Installation Chapter 2: Installation Overview This chapter contains information about installing PowerNet Software, including the following topics: Hardware and software requirements. What you receive when you purchase

More information

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A. USER MANUAL TM S6000 / S7000 S8000 / S9000 Associated Research, Inc., 2005 13860 West Laurel Drive Lake Forest, Illinois, 60045-4546 U.S.A. Item 38086 Ver 1.04 Printed Nov 15, 2005 TABLE OF CONTENTS INSTALLATION

More information

DOKOM CS. User manual 2.0

DOKOM CS. User manual 2.0 DOKOM CS User manual 2.0 1 Contents 0 INTRODUCTION 0-4 0.1 GENERAL 0-4 0.2 SUPPORTED READOUT METHODS 0-4 0.2.1 FIXED CENTRALISED READOUT 0-4 0.2.2 DECENTRALISED STATION READOUT 0-2 0.2.3 MOBILE READOUT

More information

Remote Tools User Guide

Remote Tools User Guide Remote Tools User Guide Copyright Northern Telecom 1999 Norstar is a trademark of Northern Telecom. Microsoft, MS-DOS, Windows and Excel are registered trademarks and Windows is a trademark of Microsoft

More information

PAL Installation Instructions

PAL Installation Instructions PAL Installation Instructions ADMINISTRATOR (NETWORK) INSTALLS These instructions are for PCs that are connected by a network, for the purpose of sharing PAL data and notes. PAL can be installed using

More information

RK-LINK TM Version 2.x Instructions

RK-LINK TM Version 2.x Instructions Quick Start Steps Requirements - Windows 95 or Windows NT 4.0 or later, 16MB RAM, 20-30MB Hard Disk, 486 or better processor, Serial COM Port capable of 19.2K Baud. RKAT Module must be installed at the

More information

Getting Started. ContrexHost 3. Suite of Serial Communications Applications for Contrex Motion Controls

Getting Started. ContrexHost 3. Suite of Serial Communications Applications for Contrex Motion Controls Getting Started ContrexHost 3 3200-2022 Suite of Serial Communications Applications for Contrex Motion Controls Copyright 2002 Contrex, Inc. All rights reserved. Contents Section 1 Installing ContrexHost

More information

Legacy Client Chart (LCC) Installation Guide for Purkinje System

Legacy Client Chart (LCC) Installation Guide for Purkinje System Legacy Client Chart (LCC) Installation Guide for Purkinje System A Guide to Run and Configure the Legacy Client Chart (LCC) Solution For questions about using this guide please contact IMS@aohc.org Table

More information

Galileo Print Manager Installation Guide

Galileo Print Manager Installation Guide Galileo Print Manager Installation Guide 24 November 2003 Copyright 2003 Galileo International. All rights reserved. Information in this document is subject to change without notice. The software described

More information

Preface. This guide describes the installation and activation of V7000 software.

Preface. This guide describes the installation and activation of V7000 software. Preface Scope and Objectives This guide describes the installation and activation of V7000 software. It contains all the information required to install and activate V7000 software to operate a GCOS7 system

More information

RC-SV Configuration Guide (Rev 4)

RC-SV Configuration Guide (Rev 4) Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go

More information

Single Port Serial PC Card User Manual

Single Port Serial PC Card User Manual Single Port Serial PC Card User Manual FCC COMPLIANCE STATEMENTS This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

More information

ADR View Software for Three Phase Mains Supply Analysers

ADR View Software for Three Phase Mains Supply Analysers ADR View Software for Three Phase Mains Supply Analysers Software Systems ADR-VIEW PRESENTATION AND CONTENTS Three phase mains power supply analysis software from the VEMER ADR range. The instruments are

More information

MCS Workstation Software Installation Guide

MCS Workstation Software Installation Guide MCS Workstation Software Installation Guide This document provides instructions for installing the MCS Workstation software: MCS Workstation Requirements (page 2) Installing the Workstation Software (page

More information

Meridian 1 Attendant Hospitality Services Software Installation Guide

Meridian 1 Attendant Hospitality Services Software Installation Guide Meridian 1 Attendant Hospitality Services Software Installation Guide Document Number: P0889885 Document Release: Standard 2.00 Date: June 1999 Year Publish FCC TM 1997, 1999 All rights reserved Printed

More information

ADD Comcode July CAS for Windows. Version 2.2 Addendum

ADD Comcode July CAS for Windows. Version 2.2 Addendum 555-006-517 ADD Comcode 107848756 July 1996 CAS for Windows Version 2.2 Addendum Copyright 1996 Lucent Technologies 555-006-517 ADD All Rights Reserved Comcode 107848756 Printed in U.S.A. July 1996 Notice

More information

User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS User Manual Computer Program Pomiar Win Manual number: ITKU-05-02-09-10-A Version: 4.0.X MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG Wagi Elektroniczne, 26-600 Radom 28 Bracka Street - POLAND

More information

INSTALLATION AND USER GUIDE

INSTALLATION AND USER GUIDE INSTALLATION AND USER GUIDE Introduction 1 Introduction About 6140 Agent Portal Mitel Networks 6140 Agent Portal allows an agent to receive call information via a number of different applications that

More information

Thermal Transient Test

Thermal Transient Test Thermal Transient Test Installation and Operating Manual 2705-A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 www.designconsultants.cc Hardware Installation Installation 1.

More information

Infrared Docking Station

Infrared Docking Station For uploading voice files to Enterprise Express Infrared Docking Station Operating Instructions Contents Overview...1 What s In The Box...1 System Requirements...1 Where to Go From Here...3 Getting Help...4

More information

WELDSEQ Plus. Operation / Installation Manual. Weld Sequence PLC Terminal Program. Computer Weld Technology, Inc.

WELDSEQ Plus. Operation / Installation Manual. Weld Sequence PLC Terminal Program. Computer Weld Technology, Inc. Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com WELDSEQ Plus Weld Sequence PLC Terminal Program Operation

More information

Digital thermo-hygro-barometer with external probe Manual for use

Digital thermo-hygro-barometer with external probe Manual for use COMMETER D4141 Digital thermo-hygro-barometer with external probe Manual for use Instruction manual for use of thermo-hygro-barometer COMMETER D4141 Instrument is designed for measurement and data logging

More information

Lucent Technologies CAS for Windows Version 2.2 Software Installation Notes

Lucent Technologies CAS for Windows Version 2.2 Software Installation Notes 1 Lucent Technologies CAS for Windows Version 2.2 Software Installation Notes Minimum Hardware Requirements 486/66 PC, with 16MB of memory, 500MB hard disk will handle about 500,000 calls per month for

More information

Upgrading to Octel 100 Version 3.2 from Octel 100 Version 3.1

Upgrading to Octel 100 Version 3.2 from Octel 100 Version 3.1 Upgrading to Octel 100 Version 3.2 from Octel 100 Version 3.1 This note provides the steps for upgrading Octel 100 3.1 systems to Octel 100 Version 3.2. Steps for installing OS/2 Fix Pak 40 are also provided.

More information

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet PowerLogic power-monitoring units digital panel meters Technical data sheet 2011 Authorized Distributor: WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com

More information

RC-SV Configuration Guide Revision 3

RC-SV Configuration Guide Revision 3 Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,

More information

ISDN Console Setup Utility User s Guide

ISDN Console Setup Utility User s Guide ISDN Console Setup Utility User s Guide Contents Introduction............................ 1 System Requirements.................... 1 README.TXT file...................... 1 Connecting the PC to the 2260d

More information

Table of Contents. D-Link SharePort Plus... 4 Introduction...4 System Requirements...4 Features...5. Installation... 6

Table of Contents. D-Link SharePort Plus... 4 Introduction...4 System Requirements...4 Features...5. Installation... 6 Table of Contents D-Link SharePort Plus... 4 Introduction...4 System Requirements...4 Features...5 Installation... 6 SharePort Plus Utility... 11 Utility Overview... 11 Device Server View... 12 Utility

More information

Installation. Installation 1

Installation. Installation 1 Installation 1 Installation The SP35 printer is easy to install and use. It is also flexible; you can connect and use it in many different ways. Most often, one printer is connected to one PC. However,

More information

QUICK START. DevCom2000 User Manual

QUICK START. DevCom2000 User Manual QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

NanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers

NanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers NanoWin User's Manual - Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers Page 1 of 35 NanoWin Windows 9x and Windows NT 4.0 Data Management

More information

INSTALLATION AND OPERATING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX:

INSTALLATION AND OPERATING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: ! BUNN BRW BrewWISE Recipe Writer WARNING DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEMENT OF ANY COMPONENT! INSTALLATION AND OPERATING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE

More information

SOFTWARE DNC. REF (in)

SOFTWARE DNC. REF (in) SOFTWARE DNC REF. 9701 (in) INDEX 1. Introduction... 1 2. General description... 7 3. Options... 9 3.1. Main menu... 9 3.2. Parmeters...11 3.3. Program Management...15 3.4. Tool Management...21 3.5. Machine

More information

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators Copyright 2004 AMETEK DENMARK A/S 2 124918 01 LIST OF CONTENTS Page 1. INTRODUCTION... 11 1.1 General information... 12 1.2 Hardware

More information

StrikeRisk v5.0 Getting started

StrikeRisk v5.0 Getting started StrikeRisk v5.0 Getting started Contents 1 Introduction 1 2 Installing StrikeRisk 2 7 2.1 System Requirements 2 2.2 Installing StrikeRisk 2 5 2.3 Installation troubleshooting 6 2.4 Uninstalling StrikeRisk

More information

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual SWC1090 configuration software for G.M. International Isolators series D1000 and E1000 Installation and use manual ISM0084-2 Installation and use of the SWC1090 calibration software Page 1 of 12 Index

More information

Sharp Advanced Presentation Software OPERATION MANUAL. Professional Edition Version 1.5. Transferring Images. Troubleshooting

Sharp Advanced Presentation Software OPERATION MANUAL. Professional Edition Version 1.5. Transferring Images. Troubleshooting Installing/ Uninstalling Basic Operations Adjusting and Controlling Transferring Images Saving a Custom Image Troubleshooting Glossary/ Services Sharp Advanced Presentation Software Professional Edition

More information

Comgraph32. Data Retrieval and Analysis for COMBILOG. Version Page 1. Comgraph32. data retrieval and analysis for Combilog version 3

Comgraph32. Data Retrieval and Analysis for COMBILOG. Version Page 1. Comgraph32. data retrieval and analysis for Combilog version 3 data retrieval and analysis for Combilog version 3 Page 1 3 09.00 2 04.00 Ra 1 01.99 Ra Issue Date Name Feingerätebau K.Fischer GmbH Venusberger Straße 24 D-09430 Drebach Germany Phone +49 (0) 37341 /

More information

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation

More information

Lesson 1: Preparing for Installation

Lesson 1: Preparing for Installation 2-2 Chapter 2 Installing Windows XP Professional Lesson 1: Preparing for Installation When you install Windows XP Professional, the Windows XP Professional Setup program allows you to specify how to install

More information

SCD Live SPEED TECH A/S

SCD Live SPEED TECH A/S SPEED TECH A/S Nybrovej 97. DK2820 Gentofte. Phone: +45 45938545 Fax: +45 45938544 www.doorcontrol.dk - info@speed-tech.dk Contents: SCD Live 1 INTRODUCTION... 3 1.1 DESCRIPTION... 3 1.2 DISCLAIMER...

More information

User s Manual CAP 531*1.5 Configuration and Programming tool

User s Manual CAP 531*1.5 Configuration and Programming tool User s Manual CAP 531*1.5 Configuration and Programming tool This manual belongs to: Contents Chapter Page About this manual 1 Introduction 3 Technical descriptions 81 References 177 Customer feedback

More information

SWR Director. (Version 1.11)

SWR Director. (Version 1.11) (Version 1.11) is a remote control and chart plotting of SWR and Return Loss (RL) program written for use with the AEA SWR-121 HF and SWR-121 V/U SWR analyzers. Features: Analyze an entire frequency band

More information

MX OPC Server 5.0 Help Documentation

MX OPC Server 5.0 Help Documentation 5.0 Help Documentation Contents 1. Introduction to MX OPC Server 1-1 2. Starting MX OPC Server Configuration 2-1 3. Address Space 3-1 4. Alarm Definitions 4-1 5. Simulation Signals 5-1 6. Runtime Operations

More information

Table of Contents. Introduction. 1 Installing Creative WebCam Notebook. 2 Using PC-CAM Center. 3 Creative WebCam Notebook Applications

Table of Contents. Introduction. 1 Installing Creative WebCam Notebook. 2 Using PC-CAM Center. 3 Creative WebCam Notebook Applications User s Guide Creative WebCam Notebook Information in this document is subject to change without notice and does not represent a commitment on the part of Creative Technology Ltd. No part of this manual

More information

User Manual HIGH PERFORMANCE USB GRAPHIC ADAPTER. DA Rev. 2-2

User Manual HIGH PERFORMANCE USB GRAPHIC ADAPTER. DA Rev. 2-2 HIGH PERFORMANCE USB GRAPHIC ADAPTER User Manual DA-70830 Rev. 2-2 Package Content: - 1 x USB 2.0 VGA Adapter - 1 x Driver / Manual CD - 1 x Quick Installation Guide CONTENTS INTRODUCTION...3 FEATURES...3

More information

Power Vision 1.5 (Cod )

Power Vision 1.5 (Cod ) ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.5 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 02 D) 2002 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER

More information

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique Protection and control epam range epam T Merlin Gerin quare D Telemecanique presentation contents page presentation connection characteristics installation ordering information epam T. on in in in in in

More information

Thermal Transient Test Installation and Operating Manual

Thermal Transient Test Installation and Operating Manual Thermal Transient Test Installation and Operating Manual 2705A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 descon@silcom.com www. santabarbaraautomation.com Installation

More information

Copyright Autodesk, Inc.

Copyright Autodesk, Inc. Customer and Administration Building, Ditzingen, Germany - Design by Barkow Leibinger Architects Copyright 2003-2008 Autodesk, Inc. Table of Contents 1 Introduction... 3 What is Facility Manager?... 3

More information

Galileo Print Manager Installation Guide

Galileo Print Manager Installation Guide Galileo Print Manager Installation Guide 24 November 2003 Copyright 2003 Galileo International. All rights reserved. Information in this document is subject to change without notice. The software described

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

ATL20 ATL30 Automatic transfer switch controller

ATL20 ATL30 Automatic transfer switch controller I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...

More information

TALREN 4 v 1.x. Preamble: beware, with Windows NT / 2000 / XP / 2003, the installation must be performed when connected in Administrator Mode.

TALREN 4 v 1.x. Preamble: beware, with Windows NT / 2000 / XP / 2003, the installation must be performed when connected in Administrator Mode. TALREN 4 v 1.x A. Installation procedure 1. MINIMUM HARDWARE REQUIREMENTS This CD ROM was created and is distributed by TERRASOL. It runs under Windows 98 / NT 4.0 / 2000 / XP / 2003 operating systems.

More information

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017 163C Single-Phase Multifunction Meter User Manual Version: V1 August 20, 2017 This manual may not be reproduced in whole or in part by any means without the express written permission from IPD. The information

More information

Magic Card Professional

Magic Card Professional Magic Card Professional User Manual Table of Contents System Requirements... 2 1. Installation... 3 2. Magic Card Settings... 5 2.1 Set Protection... 6 2.2 Set Parameters... 8 2.3 Password... 10 2.4 CMOS

More information

SVA NMP Monitor for Unicenter TNG on Windows NT/2000

SVA NMP Monitor for Unicenter TNG on Windows NT/2000 SVA NMP Monitor for Unicenter TNG on Windows NT/2000 Installation Guide Version 3.1.1 First Edition Proprietary Information Statement The information in this document is confidential and proprietary to

More information

Type VRLTC tap changer

Type VRLTC tap changer Report No. 1ZUA938502-AGC 2, Rev 0 Date: 6 November 2012 Type VRLTC tap changer Ruggedized electronics systems specification & type test data Product Style No Rating By Type VRLTC, on-tank, vacuum reactance

More information

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL Windows 2000 Platform Description and Installation Instructions This manual has been developed by NEC America, Inc. It is intended for the use

More information

USB to Serial Converter User s Guide

USB to Serial Converter User s Guide USB to Serial Converter User s Guide Important Note! In order to minimize possible installation problems and/or resource conflicts: Read Me First! About This User s Guide This User s Guide is designed

More information

N2KAnalyzer. User s Manual

N2KAnalyzer. User s Manual N2KAnalyzer NMEA 2000 Network Analysis Software User s Manual Revision 1.3.9 Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

NDA ISSUE 1 STOCK # MATWorX 32 User s Guide. December, NEC America, Inc.

NDA ISSUE 1 STOCK # MATWorX 32 User s Guide. December, NEC America, Inc. NDA-24215 ISSUE 1 STOCK # 151942 MATWorX 32 User s Guide December, 1997 NEC America, Inc. LIABILITY DISCLAIMER NEC America, Inc. reserves the right to change the specifications, functions, or features,

More information

OKIFAX 5650 MFP Option Kit. Overview. Setup Guide

OKIFAX 5650 MFP Option Kit. Overview. Setup Guide OKIFAX 5650 MFP Option Kit Overview Setup Guide Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility

More information

TeleOximetry PC Access Software

TeleOximetry PC Access Software TeleOximetry PC Access Software 3900/3900P Pulse Oximeter Datex-Ohmeda, Inc. 6050-0006-493/A 1315 W. Century Drive, Louisville, CO 80027 USA 2002 Datex-Ohmeda, Inc. www.datex-ohmeda.com All rights reserved.

More information

PictureTel LiveGateway Version 3.1 Online Installation Guide

PictureTel LiveGateway Version 3.1 Online Installation Guide PictureTel LiveGateway Version 3.1 Online Installation Guide Welcome to the PictureTel family of industry standard, videoconferencing products designed specifically for the Local Area Network (LAN). The

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

EMS Installation. Workstation Requirements CHAPTER. EMS Lite (Windows 95/98) EMS NT (Windows NT 4.0)

EMS Installation. Workstation Requirements CHAPTER. EMS Lite (Windows 95/98) EMS NT (Windows NT 4.0) CHAPTER 2 EMS Installation This chapter provides instructions for installing the Element Management System (EMS) software on a user workstation. Workstation Requirements The following sections list the

More information

1. PARVEX MOTION EXPLORER INSTALLATION 2 2. PARVEX CONTROL PANEL 4

1. PARVEX MOTION EXPLORER INSTALLATION 2 2. PARVEX CONTROL PANEL 4 Contents 1. PARVEX MOTION EXPLORER INSTALLATION 2 1.1 Hardware and Software Set-up 2 1.2 User's licence 2 1.3 Installation - Operating Mode 3 2. PARVEX CONTROL PANEL 4 2.1 Functions of the software 4 2.2

More information

ScanVision Program for Setup and Monitoring of RJS SV Type Scanner/Verifier Products P/N Rev D

ScanVision Program for Setup and Monitoring of RJS SV Type Scanner/Verifier Products P/N Rev D ScanVision Program for Setup and Monitoring of RJS SV Type Scanner/Verifier Products P/N 002-8151 Rev D a subsidiary of Printronix, Inc. 14600 Myford Road Irvine, CA 92606 +1 (714) 368-2781 fax: +1 (714)

More information

mobile PhoneTools User s Guide

mobile PhoneTools User s Guide mobile PhoneTools User s Guide Contents Requirements...2 Installing mobile PhoneTools...3 Mobile installation and configuration...4 Online registration... 6 Uninstalling mobile PhoneTools... 6 mobile PhoneTools

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6) Model C-322 Datalogging Sound Level Meter Instruction Manual Tripod sold separately (Model BS-6) reedinstruments com Table of Contents Features... 3 Specifications... 3 Instrument Description...4-5 Operating

More information

TOF-Watch SX Monitor

TOF-Watch SX Monitor TOF-Watch SX Monitor User manual Version 1.2 Organon (Ireland) Ltd. Drynam Road Swords Co. Dublin Ireland Contents General information... 3 Getting started... 3 File Window... 7 File Menu... 10 File Open

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for SP Efecto / SP Brilliant (Plus) / SP Initial Table of Contents 1. WatchPower Overview...1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install

More information

PL200M. 200Mbps powerline adapter. User Manual

PL200M. 200Mbps powerline adapter. User Manual PL200M 200Mbps powerline adapter User Manual Content 1 Introduction... 130 1.1 System Requirements... 130 1.2 Packing List... 130 2 Safety Precautions... 131 3 Getting to Know the Adapter... 132 3.1 Ethernet

More information

Wireless transfer of screening data from ALGO 3i Screener to PC

Wireless transfer of screening data from ALGO 3i Screener to PC Wireless transfer of screening data from ALGO 3i Screener to PC This technical notice provides information on transmitting screening results from your ALGO 3i Newborn Hearing Screener to a personal computer

More information

Before you attempt to upgrade from the Live200 system to LiveLAN 3.1, make sure that you have the following:

Before you attempt to upgrade from the Live200 system to LiveLAN 3.1, make sure that you have the following: Overview This section describes the basic requirements necessary to upgrade your Live200 system to Live LAN 3.1. For more detailed information on the LiveLAN 3.1 system requirements, please refer to the

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Product datasheet Characteristics TM221CE40R controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete

More information

ADVENT TM DOWNLOADER f o r W I N D O W S U S E R 'S G U I D E

ADVENT TM DOWNLOADER f o r W I N D O W S U S E R 'S G U I D E TM ADVENT DOWNLOADER B H 9 1, 95 7 5-45 / 71,- For reprints, order manual: 466-1698 Rev. B Copyright ITI 2000 Printed in the U.S.A. i Interactive Technologies, Incorporated (ITI) provides this publication

More information

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES... 3 CHAPTER

More information

FA-B30 Version 1.0 Basic Label Printing Software

FA-B30 Version 1.0 Basic Label Printing Software FA-B30 Version 1.0 Basic Label Printing Software For Windows User s Guide This Label Printing Software can be used with a number of different Basic Label Printer models. See page 11 of this manual for

More information

User's Manual. TA320/TA520 Optical Disk Inter-Symbol Interference Analysis Software. IM E 1st Edition. IM E 1st Edition

User's Manual. TA320/TA520 Optical Disk Inter-Symbol Interference Analysis Software. IM E 1st Edition. IM E 1st Edition User's Manual TA320/TA520 Optical Disk Inter-Symbol Interference Analysis Software 1st Edition 1st Edition Foreword Notes Trademarks Revisions Thank you for purchasing the Optical Disk Inter-Symbol Interference

More information

DCN Software Installation Instructions. en Software Installation Instructions

DCN Software Installation Instructions. en Software Installation Instructions DCN Software Installation Instructions en Software Installation Instructions DCN Software Installation Instructions en 3 Table of contents 1 Introduction... 4 2 Installing the DCN software... 5 3 Installation

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Characteristics controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Jan 6, 2019 Modicon M221 Logic controller 100...240 V AC Discrete input number

More information

Software Manual Virtual COM for Ethernet Driver / Configuration Tool

Software Manual Virtual COM for Ethernet Driver / Configuration Tool Software Manual Virtual COM for Ethernet Driver / Configuration Tool Rev. 2.08 SRP-270 / SRP-275 SRP-275II / SRP-280 SRP-350 / SRP-350II SRP-350IIK SRP-350plus / 352plus SRP-350plusII / 352plusII SRP-500

More information

SERVICE TOOL MAP110 USER MANUAL. Landis+Gyr. H c en

SERVICE TOOL MAP110 USER MANUAL. Landis+Gyr. H c en SERVICE TOOL Landis+Gyr MAP110 USER MANUAL H 71 0200 0332 c en Revision History Index Date Comments a 28.02.2005 First edition b 31.05.2005 Changes to release 1.1 c 22.09.2005 Changes to release 1.2 subject

More information

TM221M32TK controller M IO transistor PNP

TM221M32TK controller M IO transistor PNP Characteristics controller M221 32 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491)

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491) ICS Regent Multiplexed I/O Modules (T3491) Issue 1, March, 06 Multiplexed I/O modules provide two RS-422 serial port interfaces between the Regent system and ICS s remote multiplexed I/O Unit (MIU) equipment,

More information

PC Connecting Kit. Operating Instructions

PC Connecting Kit. Operating Instructions 3-859-881-23(1) PC Connecting Kit Operating Instructions For the latest information on this product For Windows: Refer to the readme.txt file on the supplied CD-ROM. For Macintosh: Refer to the ReadMe

More information

Cleo A+ for Windows Installation Guide November 2001

Cleo A+ for Windows Installation Guide November 2001 Cleo A + for Windows I n s t a l l a t i o n G u i d e November 2001 Cleo A + for Windows Installation Guide Version 2.36 combined November 2001 RESTRICTED RIGHTS Use, duplication, or disclosure by the

More information

RemoteWare OS/2 Client

RemoteWare OS/2 Client RemoteWare OS/2 Client User s Guide Version 4.1 Service Pack 1A RemoteWare OS/2 Client User s Guide Version 4.1 Service Pack 1A This document was prepared to assist licensed users of RemoteWare by XcelleNet,

More information

Centralized monitoring software Monas-NET

Centralized monitoring software Monas-NET Communications for security Centralized monitoring software Monas-NET (Version 1.56) User guide Content 1. Application of the programme MONAS-NET 3 2. Security of the programme 3 3. Programme components

More information

Windows 2000 Safe Mode

Windows 2000 Safe Mode LAB PROCEDURE 29 Windows 2000 Safe Mode OBJECTIVES 1. Restart and try various startup options. RESOURCES Troubleshooting 1. Marcraft 8000 Trainer with Windows 2000 installed 2. A PS2 mouse 3. A LAN connection