AAPM Standard of Practice: CT Protocol Review Physicist

Similar documents
CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Computed Tomography Imaging: CT Protocol Management. Caveat 8/3/2017

Implementation and evaluation of a protocol management system for automated review of CT protocols

Real World Experience: Developing Dose and Protocol Monitoring from Scratch

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

AIDR 3D Iterative Reconstruction:

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Optimisation of Toshiba Aquilion ONE Volume Imaging

ABR CERTIFICATION OF MEDICAL PHYSICISTS CERTIFICATION AMERICAN BOARD OF RADIOLOGY 7/22/2014

Preparing for Part 2 of the ABR Diagnostic Physics Exam

PRODUCT DATA. Advanced 128

Kevin O Donnell Senior R&D Manager Toshiba Medical Research Institute Co-Chair, DICOM Standards Committee Past Chair, IHE Radiology Planning

Lower Dose, Compact Design

Solid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning

Viswanathan Venkataraman, MS, M.Tech. Travis Browning, MD Seth Toomay, MD Ivan Pedrosa, MD Suhny Abbara, MD David Fetzer, MD Ronald Peshock, MD

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

Certification of Physicians and Non- Physicians in the United States

Choosing a teleradiology provider

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

RADIOLOGY AND DIAGNOSTIC IMAGING

7/13/2015 EVALUATION OF NONLINEAR RECONSTRUCTION METHODS. Outline. This is a decades-old challenge

INTERNATIONAL STANDARD

QIBA Profile: CT Tumor Volume Change for Advanced Disease (CTV-AD)

MUSICA makes the difference

GPU implementation for rapid iterative image reconstruction algorithm

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

As fl exible as your care requires

QIBA Profile: CT Tumor Volume Change for Advanced Disease (CTV-AD)

Acknowledgments and financial disclosure

Computer-Tomography II: Image reconstruction and applications

S. Guru Prasad, Ph.D., DABR

Limits of Dose Reduction in CT: How low is too low? Acknowledgement. Disclosures 8/2/2012

James R Halama, PhD Loyola University Medical Center

Digital Imaging and Communications in Medicine (DICOM) Supplement 121: CT Protocol Storage

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Future is Effortless

Retrospective Spiral Respiratory Correlated Imaging with Varian RPM

SCENARIA 64-Slice CT Putting Advanced CT Within Reach.

Protocol Management and Review Strategies: The Mayo Experience

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

QIBA Profile: CT Tumor Volume Change for Advanced Disease (CTV-AD)

What is New In MOC? Anne Roberts, M.D. UCSD Medical Center

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

CURRICULUM COMMITTEE MEETING Friday, March 18, :00 p.m. Student Life Center, Faculty Dining Room (Building 23, First Floor) AGENDA

Lower Dose with Confidence

Philips SPECT/CT Systems

ACMP 25th Annual Meeting

Hitachi Medical Systems America, Inc. Hitachi Medical Corporation

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

2018 CANADIAN ELECTRICAL CODE UPDATE TRAINING PROVIDER PROGRAM Guidelines

MOC Update for Medical Physicists ABR MOC Medical Physics 3/14/2017 Disclosures NOTE Maintenance of Certification Why do we have MOC?

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Ch. 4 Physical Principles of CT

A closer look at CT scanning

CNSC Presentation to the Federal Agency for Nuclear Control

ABR Update: MOC & PQI. Lane F. Donnelly MD Nemours Children s Hospital Orlando, FL

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Learning Objectives. NCTRC Specialty Certification ATRA Academy Webinar Series F: A Comprehensive Overview of the CTRS Certification Process

ImPACT. CT dosimetry and a data base for CTDI values. EFOMP Workshop at ECR Imaging Performance Assessment of CT Scanners

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

QUALITY ASSURANCE POLICY. Quality Assurance Policy. September 2016 Version 2.0 Policy authorised by Responsible Officer

By choosing to view this document, you agree to all provisions of the copyright laws protecting it.

DX-D 100 with wireless detector

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

The Texas A&M University System. Internal Audit Department. Fiscal Year 2014 Audit Plan

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

Agenda : Lung Density Breakout Session

INSPIRED BY YOUR PATIENTS.

7/30/2018. QC Considerations for Mobile Devices. Outline. No disclosures.

Management of Acquisition Protocols (MAP) IHE Radiology Domain Kevin O Donnell, Toshiba Medical

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

DX-D WITH DX-D 40/45 DETECTOR FAMILY MOBILE DR SOLUTION

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

8/3/2011. Implementation Status. Yes (EI and DI) On all new equipment Legacy systems can be upgraded (digitizer (plate reader) upgrade not required).

4DM Packages. 4DM Packages & License Types. Information to help you order the appropriate licenses for your site.

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

DX-D 100 WITH WIRELESS DETECTOR

ThE ultimate, INTuITIVE Mr INTErFAcE

Dose Calculation and Optimization Algorithms: A Clinical Perspective

Tomographic Reconstruction

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Image Guidance and Beam Level Imaging in Digital Linacs

KENYA SCHOOL OF GOVERNMENT EMPLOYMENT OPORTUNITY (EXTERNAL ADVERTISEMENT)

CTA HEAD Perfusion AqONE without and with IV Contrast

Micro-CT Methodology Hasan Alsaid, PhD

MENTAL RETARDATION BULLETIN

SAVANNAH LAKES VILLAGE PROPERTY OWNERS ASSOCIATION, INC. JOB DESCRIPTION

CT Iterative Reconstruction Techniques

PVDOMICS. Chest CT Scanning and Data Transmission. Jason Lempel, MD Lung Imaging Core Data Coordinating Center Cleveland Clinic Nov.

Welcome Membership Update Sub-group / Initiatives update Investigator TMF Clarifications Sub-artifacts Observational Studies Exchange Mechanism

Experience Boundless Performance

Using a local Dose Index Registry system to determine Notification Values for the MITA XR 25 (Dose Check) Standard in CT

Security and Privacy Governance Program Guidelines

The Human Touch: Develop a Patient-Centric Injection Device

Web Users Group, August Web Accessibility FAQ

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

CT vs. VolumeScope: image quality and dose comparison

Digital Image Processing

Transcription:

AAPM Standard of Practice: CT Protocol Review Physicist Dianna Cody, Ph.D., DABR, FAAPM U.T.M.D. Anderson Cancer Center September 11, 2014 2014 Texas Radiation Regulatory Conference

Goals Understand purpose and importance of CT Protocol Review Understand AAPM MPPG 1.a. Understand roles of protocol review committee Demonstrate team member contributions through real-life examples

AAPM Medical Physics Practice Guideline 1.a: CT Protocol Management and Review Practice Guideline JACMP 14(5): 3-12, 2013 AAPM website http://www.aapm.org/pubs/mppg/documents/mppg1a.pdf

AAPM Medical Physics Practice Guideline 1.a. AAPM CT Protocol Management and Review Practice Guideline

Organization of the Practice Guideline 1. Introduction 2. Definitions 3. Staffing Qualifications and Responsibilities 4. Essential Elements of the Protocol Management Process 5. Conclusion 6. References

Introduction The review and management of computed tomography (CT) protocols is a facility s ongoing mechanism of ensuring that exams being performed achieve the desired diagnostic image quality at the lowest possible radiation dose exploiting the capabilities of the equipment Protocol review and management is an essential activity in ensuring patient safety and that diagnostic images are produced. The AAPM considers these activities to be essential to any quality assurance (QA) program for CT, and as an ongoing investment in improved quality of patient care.

Introduction Review, implementation and verification of protocols within a practice Complex undertaking in the present environment Challenges in optimization of dose and image quality are compounded by a lack of automated mechanisms to collect and modify protocols Manual labor involved in this process is NOT inconsequential

Application of the MPPG This MPPG only applies to CT scanners used for diagnostic imaging. It is not applicable to scanners used exclusively for: Therapeutic radiation treatment planning or delivery; Only calculating attenuation coefficients for nuclear medicine studies; or Image guidance for interventional radiologic procedures. However, CT protocol review is encouraged in these settings!!

The Team Must be responsible for protocol design and review of all parameter settings. Each team member brings different expertise and may have different responsibilities in the Protocol Review and Management process. To be successful, it is very important that the expectations of roles and responsibilities of each member are clearly described. The ability to work together as a team will be important attributes of each member of this group.

Team Members Lead Radiologist Lead CT Technologist QMP Maybe an administrator

Other duties for this team??? CT Accreditation Planning Submission Radiation Protocol Committee Recent Texas regulations Add Radiation Safety Officer

Responsibilities of the QMP QMP s responsibilities may vary, but the QMP must be involved in the review of all protocols. Involvement in protocol process may depend on status of QMP in house vs consultant In-house QMP expected to be more immersed than consultant, devote more time & effort

Lead Radiologist Often will function as team leader (maybe not in large facilities) Driver for image quality requirements Contrast? Image thickness? Recon kernel? Multi-phase? Timing? Acceptable noise level Special post-processing

Lead Technologist May be single point person or shared duty Patient handling issues Oral contrast requirements Patient positioning Injection delays Breathing instructions Post-processing Usually source of best information about CT scanner capabilities & limitations

The Protocol Management Review Process All new or modified protocol settings for existing and new scanners Ensure that both image quality and radiation dose aspects are appropriate. Review of existing protocols Implementation of new and innovative technologies that can improve image quality and/or lower patient dose in comparison to the older protocol.

The Protocol Management Review Process (continued) Specific capabilities of each individual scanner minimum rotation time automatic exposure controls tube current modulation kv selection technologies reconstruction algorithms iterative reconstruction Achieve maximum performance of the system It should include a review of the most current literature.

Considerations Important During Review of a Protocol Recommendations for State and National Guidance The QMP must be familiar with applicable federal law and the specific requirements for the state or local jurisdiction where the facility is located. Protocol review and management, while not always explicitly required by state law or regulation, may often facilitate compliance with many provisions within state laws and regulations relating to radiation dose from CT.

Considerations Important During Review of a Protocol (continued) Frequency of Review The review process must be consistent with federal, state and local laws and regulations. If there is no specific regulatory requirement, the frequency of protocol review should be no less frequent than 24 months. This review should include all new protocols added since the last review. However, the best practice would be to review the most-frequently-used protocols at least annually.

Protocols that Require Annual Review If a facility performs the following six clinical protocols, the CT Protocol Review and Management team must review these annually (or more frequently if required by state or local regulatory body). Pediatric Head (1 year old) (if performed) Pediatric Abdomen (5 year old; 40-50 lb. or approx. 20 kg) (if performed) Adult Head Adult Abdomen (70 kg) High Resolution Chest Brain Perfusion (if performed)

Clinically Significant Protocols that Require Annual Review Facilities that do not perform these six protocols must select other protocols at their facility: most frequently performed or higher-dose protocols total at least six protocols for annual review.

Considerations Important During Review of a Protocol (continued) Protocol Naming Consider naming CT protocols in a manner consistent with the RSNA RadLex Playbook (soon to release new version). Provides a more consistent experience for patients and allows more direct comparison among facilities. Allows more direct utilization of the ACR Dose Index Registry tools and Provides more efficient automated processes with postprocessing workstations. Appropriate protocol naming may result in fewer technologist errors and allow more efficient comparison of protocol parameters between scanners. Consider incorporating version dates in protocol names.

Considerations Important During Review of a Protocol (continued) Permissions Document who has permission to change protocol parameters on the scanner(s). Use of password protection is encouraged if available. Document process of making protocol adjustments and the frequency of these adjustments. Include approvals & documentation process (e.g., a change control log documenting the rationale and who authorized or motivated the change).

Helpful Tool Method for keeping track of protocol review status Outline steps required Log process to date Process may stall and need to be restarted Running list of all protocols in flux Waiting list of those to tackle next

Considerations Important During Review of a Protocol (continued) Acquisition Parameters should be reviewed to ensure they are appropriate for the diagnostic image quality noise level spatial resolution minimizing radiation dose For example, a slow rotation time and/or low pitch value would not be appropriate for a chest CT exam due to breath-hold issues. Parameters include: kv, ma, rotation time, collimation or detector configuration, pitch, etc.

Considerations Important During Review of a Protocol (continued) Reconstruction parameters should also be reviewed to ensure appropriate diagnostic image quality necessary for the clinical indication(s) for the protocol. The parameters include: image thickness reconstruction interval reconstruction algorithm/kernel/filter the use of additional image planes (e.g., sagittal or coronal planes, etc.)

Considerations Important During Review of a Protocol (continued) Advanced dose reduction techniques should be considered provided the use of such techniques is consistent with the goals of the exam. Depending on the capabilities of each specific scanner, consider use of the following if they are available: Automatic exposure control (e.g., tube current modulation or kv selection) methods Iterative reconstruction techniques

Considerations Important During Review of a Protocol (continued) Adjustments of acquisition parameters should be adjusted for patient size manual adjustments (technique chart) automatic methods (such as tube current modulation kv selection

Considerations Important During Review of a Protocol (continued) Radiation dose management tools Identify potentially high radiation dose scans being prescribed. MITA XR25 standard ( CT Dose Check ). Monitor doses from routine exams and collect data. These would allow statistical analysis of dose parameter values for a specific exam or clinical indication (e.g., average CTDI vol for a routine non-contrast head). Participation in a national registry (such as the ACR Dose Index Registry). Commercial products now available for this purpose.

Considerations Important During Review of a Protocol (continued) Populating Protocols Across Scanners Process by which protocol parameters are populated across additional scanners manually copy/paste Master scanners in the facility where manual protocol adjustments are made and archived, and that set of protocols moved to the other similar scanners, or if another strategy will be employed.

Considerations Important During Review of a Protocol (continued) Documentation All changes to protocols and historical protocols should be available for review. Include the rationale for changes. Latest protocol should be readily and obviously available to users during clinical protocol selection. Who is responsible for maintaining the overall protocol description documentation. Describe whether the protocol description documentation is accessible to others for reference, how often it is updated and how all protocols are archived.

Considerations Important During Review of a Protocol (continued) Periodic vendor specific education/refresher sessions Each member of the CT Protocol Management Process team should receive refresher training no less than annually or when new technology is introduced that substantially impacts image quality or dose to the patient. Available educational resources should be considered in order to keep staff updated on current best practices. Periodic refresher training should be scheduled for all members of the CT Protocol Management Process team.

Considerations Important During Review of a Protocol (continued) Verification Regular review process of protocols to be sure that no unintended changes have been applied that may degrade image quality or unreasonably increase dose. As a best practice, the CT Protocol Review and Management team should conduct a random survey of specific exam types to verify that the protocols used are acceptable and consistent with protocols specified above. Acquisition and reconstruction parameters Image quality Radiation dose

CT Protocol Review Examples Last 3 CT protocol reviews at MD Anderson: Liver CT Exam Pediatric Abdomen CT Exam Liver CT Protocols

Example 1 Siemens scanner Liver exam Radiologist: thin images are missing Technologist: they are not included in the protocol QMP: radiation dose quite high for all passes?!? Same quality reference mas used for all passes Big Woops Corrections made regarding acquisition & reconstruction parameters

Example 2 QMP: ACR Accreditation testing - pediatric abdomen dose levels VERY LOW. Unlikely to pass low-contrast test. Radiologist: we ve been complaining about noisy pediatric abdomen images for ages, GO FOR IT Technologist: be careful when increasing ma; pediatric scan field of view imposes an ma limit. Solution: increased dose to all pediatric abdomen/pelvis exam protocols. Image quality reference parameter and/or kv

Example 3 Everyone: we have TOO MANY liver protocols! Pre-surgical, routine, GSI liver, etc Radiologist: Need better and more consistent image quality than we are getting now. Technologist: There are too many protocols to choose from (easy to make an error). QMP: We can design a single protocol for this exam that has the IQ needed for all patients. Results: Less confusion, more consistent IQ, fewer complaints.

Conclusion CT protocol management and review is a critical part of a CT facility s operation Considered important by many state regulatory bodies, accrediting and professional organizations. Protocol parameter control and periodic review will help maintain the facility s image quality to acceptable levels assure patient safety continuous improvement in the imaging practice.