AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

Similar documents
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Switched Ethernet Service SM

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

Add an AT&T Switched Ethernet Service port to your site

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

Construction Guidelines. for Providing Communications Services

AT&T Collaborate. IAD (s)

Tarleton State University. Specifications

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

Managed WAN SLA. Contents

ANSI/TIA/EIA-568-B Cabling Standard

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Installation Notes TII Model 341 Protector

Managed WAN SLA. Contents

Business Customer Demarcation Information

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

Basketball Shot Clock Set LX2180 Manual

Installing the Cisco MDS 9020 Fabric Switch

PIX 520. PIX 520 Product Overview CHAPTER

Site Preparation CHAPTER

FEMTOCELL MULTI-BAND SOHO B2/B4 (SS2FII)

ANSI/TIA/EIA-568-B Cabling Standard NOTE

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

Cabling Infrastructure

Target Interface / Construction Compliance Inspection Checklist

Replacing an ESM/IOM CRU in the CSM200 Drive Module

Contractor Work Packet

Computer Network Design Guide Existing Systems 1 / 6

PARTNER Contact Closure Adjunct

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

CENTRAL TELEPHONE COMPANY NEVADA DIVISION ( SPRINT ) NEVADA LOCAL TERMS OF SERVICE

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

TIA/EIA 568A Sub-system HORIZONTAL CABLING

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Installing the Cisco AS5400XM Universal Gateway

AT&T INTERSTATE ACCESS GUIDEBOOK PART Special Access Services - East

iconverter 2-Module Power Chassis

T3 Interface Converters

CSM200 Expansion Tray

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

KillTest. 半年免费更新服务

Equipment Installation Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

RS-232 Fiber Link Card System

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

EP-ELVCTL Elevator Control (NION-16C48M)

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

NZQA unit standard version 2 Page 1 of 5

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

FIBER OPTIC HARDWARE STEVE PAULOV

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Delivered the Way Yo u Want

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Intelligent Channel Bank Shelf

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

PIX 535. PIX 535 Product Overview CHAPTER

Power Supply (48Vdc, 2.5A)

The six major components of a structured wiring system are:

A/E REVIEW CHECKLIST TELECOMMUNICATIONS SYSTEMS

PREVENTING DOWNTIME OF E911 CENTERS

EMC Symmetrix VMAX Cloud Edition

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

ADTRAN ProServices Description of Service Offering. ProStart Remote Installation Services ActivReach Ethernet Switches

Nortel Business Communications Manager Installation System. Release: 5.0 Document Revision: NN

Broadband Automatic Disconnect Switch. User Manual

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

Spring Test 9 due 05/11/2013

Installation Job Aid for Ethernet Routing Switch 3600 Series

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

Target Interface / Construction Compliance Inspection Checklist

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

4100/ VDC Converter Installation Instructions

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Explore installation guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

DIVISION 27 COMMUNICATIONS

INSTALLATION INSTRUCTIONS FOR

Network+ Guide to Networks 7 th Edition

Transcription:

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide This guide is designed to assist local on-site contacts to understand what you will need to accomplish in preparation for transport install 2017 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo, Mobilizing Your World and DIRECTV are registered trademarks and service marks of AT&T Intellectual Property and/or AT&T affiliated companies. All other marks are the property of their respective owners.

AT&T ADI and PNT on Ethernet Site Preparation Guide AT&T will perform with your permission: Customer will perform the following: Meet with the AT&T engineer An AT&T engineer will explain to your site contact all customer responsibilities shown on this page The engineer will reach out to the site contact within 48 hours of your order to schedule a visit If you are eligible for the entrance facility offer*, AT&T will complete items 2-5 on this list. This will occur after you sign the systems permissions form If the entrance facility offer is not available in your area, you will be responsible for completing the work or hiring someone to complete the work Outside conduit specifications (Property Line to your building) Minimum 2 4 conduit with pull rope Minimum 3 sweeping radius Pull box required when: There are 3 or more right angles The path is longer than 300 *Dimensions for pull box 12 x 12 x 18 Wall mounted backboard 4 x 4 x 3/4 Fire retardant plywood Mounted to studs Electrical specifications AC power outlet on a dedicated fused breaker rated min. 15 amps OR Nominal voltage, 48VDC, +24/-24VDC, 110V Either power option needs to be located within 6 ft. of the AT&T equipment Multiple outlets required for all equipment Relay racks, cabinets, routers and your CPE must be grounded Inside conduit specifications (Demarcation point to router) Needs to be completed prior to installation You may hire an electrical vendor to complete inside wiring A conduit or cable tray is required, and a clear path for access Minimum 2 conduit Additional inside wiring Inside wiring, unless otherwise noted, is your responsibility; you can do it yourself or hire a vendor Inside wiring includes: From the demarcation point to your ADI equipment (router) Note: Incomplete inside wiring is the number one reason for service delays Telephone land line (not mobile) Managed options require a land line If you do not have a land line, talk to your sales person about ordering one 2

AT&T ADI and PNT site preparation guide all offers Site Survey Site contact responsibilities Site contact responsibilities If in a multi tenant building AT&T will reach out to your local Obtaining building access and Overseeing the site build out Working with the property site contact to schedule a site being familiar with the telecom and confirming the completion manager or building owner to survey, if applicable rooms dates. The contact should be determine the location of your Please provide the local customer site contact information: Showing AT&T where the circuit demarcation (demarc) is fully empowered to make decisions company s demarc Acting as a liaison and Name / Title located. The demarc is inside the building where the service Informing us of any parking, noise or time restrictions; advocate when working with the building owner or manager Phone number / Email The site contact will work with AT&T to schedule building access, provide the installation address to the ordering team and problem solve, as needed terminates from the street Guiding AT&T during the site survey visit, noting further action needed to complete the site requirements (take notes) unloading zones, elevators, asbestos, hazardous materials, etc. Providing adequate working space, a clear path and easy access to the backboard, jack, land line, power outlets and the Confirming the demarc is in the same room as the router Providing inside wiring if the building s demarc is not in your location or on a different floor than the ADI router AT&T ADI router 3

AT&T ADI and PNT site preparation guide Site preparation delays Customer site not ready What to expect during site survey visit AT&T will negotiate a project schedule with all parties to enable service completion as close to your desired date as possible However, any changes to plans or any delays associated with site preparation can have a corresponding impact to the service delivery date Please try to complete the site preparation as soon as possible from the time you place your order. This includes any electrical requirements, the backboard for the network equipment and any applicable extended inside wire. This will help avoid an installation delay Please contact the AT&T ordering team and your account team representative if delays are anticipated so work forces can be rescheduled There are billing implications if the site is not ready in time The local site contact will meet with the AT&T engineers to walk through what he or she will need to complete before we can install the service. It s a good idea to take notes and keep the name and contact information of the engineer in case there is a question later We will keep the site contact notified if there are any delays on our end, such as special construction, or facility delays 4

AT&T ADI and PNT Site Preparation Guide General requirements Inside path The following pages contain information and a list of general requirements associated with fiber optic-based services. The AT&T access engineer or field technician will identify actual requirements for the specific installation during the site survey Share this information with your electrical contractor There are typically four (4) areas of customer obligation to facilitate timely equipment installation and delivery of service: Inside path Ground Power Floor space and environmental requirements For an additional fee, you can hire AT&T or an electrician to complete the inside wiring The inside path is the wiring that goes from the point where we bring the service to your building (demarc) to your ADI router The conduit must be a minimum 2 with a hard plastic corrugated interior duct, with pull rope If the building is shared by multiple tenants, the router and the demarc will likely not be in the same location. You will need to work with the building manager or building owner to coordinate the inside wiring Inside wire extensions take time, so you will want to schedule that as soon as possible. The AT&T engineer will be able to answer any questions 5

AT&T ADI and PNT Site Preparation Guide Grounding Grounding your router is your responsibility, we encourage you to consult with your electrical contactor AT&T provided equipment, customer relay racks, cabinets and router must be grounded by placing an exposed #6 or larger grounding wire to the building s ground source This ground wire will be attached to the closest ground rod (earth ground) or building bus bar available and run to the network terminating equipment location in the room All equipment requires a properly grounded 110v, 15 amp, 3-prong AC outlet Not properly grounding your equipment will result in service quality and maintenance issues A #6 stranded ground is required from your earth electrode system to the equipment room. This would be connected to a grounding bus bar, or otherwise directly connected to different components A #6 stranded ground is required from the grounding bus bar to the network terminating equipment Specific requirements may also be discussed with the AT&T access engineer or AT&T field technician at the time of the site survey visit 6

Presentation title here edit on Slide Master AT&T ADI and PNT site preparation guide Power Customer environmental responsibilities Network device Please provide a dedicated 110V circuit breaker rated at a minimum of 15 amps for the network device that connects your building to the AT&T network. The power cord must not be touching any other cables ADI router In addition, please provide a 110V outlet for the router and the modem. A modem is provided if you ordered an AT&T managed router A 4 x 4 x 3/4, fire retardant backboard, fastened to studs is required A (customer provided) regular telephone line should be installed prior to the router installation. The ADI router should be installed less than 15 feet from the jack that connects to the router. The distance will ensure the cable inside the router box will reach the jack This line will be connected to the Operating environment should modem and used by the AT&T be between 40 (degrees) F and installation engineer during the 85 (degrees) F to 85% relative test and turn-up of your ADI humidity service. It also allows for testing Because of the small size of most in the event of circuit network termination equipment, interruption during the life of the a wall mounted installation is service recommended (please see illustration on the next page) Another option would be a (customer provided) 19 rack of suitable strength and quality is also acceptable The choice for placement should be decided before the order is placed and is subject to confirmation following the site survey In a standard fiber installation, transport equipment is placed in a common area with access to the entire building. 7

Wall Mount Example Wall mount example 4 X 4 X 3/4 fire retardant plywood backboard mounted to studs Ethernet patch cable Fiber termination panel Orange Customer provided Blue- AT&T provided Optional fiber jumpers (caution: bend radius) Fiber drop Cable to ADI router (optical handoff) Fiber panel (optional) Network termination equipment 110V power cord 110V amp outlet, properly grounded, 3 prong 8

AT&T ADI and PNT Network Example modem Land line for out of band testing **LAN connection to customer equipment *WAN connection Circuit dmarc AT&T provided router Local exchange carrier access Notes: This diagram is illustrative for AT&T Dedicated Internet (ADI) Customer will provide the land line *AT&T assigned WAN IP s **Usually these are AT&T assigned LAN IP s AT&T point of presence Interoffice channel ADI point of presence & network 9