NEXO S. A. Parc D Activité NEXO LatAM Tel: Fax:

Similar documents
NXAMP4x4 Powered TDController

Compact Sound Reinforcement System

Compact Sound Reinforcement System

Multi-Mode Power Amplifiers for your Most Demanding Installations

LA8 Amplified Controller

Taking line array performance to a whole new level

LA-RAK II TOURING RACK

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

SYNAPSE. High Channel Density Networked Audio Interfaces AES67. Common Features DM 1. D32 o. D32 i. Product Family Overview. Applications.

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

xin 4, xio 4x4 and xout 4

TitanONE Smart Mainframe Power Amplifier

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

ControlSpace EX-1280C conferencing processor

System Interface Unit SIU-100/100T

DL-HDM44A-H2 Quick Install Guide

Software Suite Configure. Manage. Update.

VIPEDIA-12. Cameo specification sheet. Product Description

ASP-MG2240. Amplified Sound Masking System

PRO SERIES DL155. # Designed and engineered in the U.K.

M7CL-48ES M7CL-48 M7CL-32. M7CL Version3. Digital Mixing Console. *Peak Meter Bridge MBM7CL is option. *Peak Meter Bridge MBM7CL is option.

OVERVIEW SYSTEM REQUIREMENTS

Data sheet FC-9 DSP system controller. Amp Contoller-Series DSP-Amplifiers + DSP-Controller.

ControlSpace ESP-00 Series II TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

DL32R. 32-Channel Wireless Digital Live Sound Mixer with ipad Control

SmartAudio: SSA Feature Summary

MATRIX-MIXERS AUTOMIXER AX 8042 and ZONER ZX 8060 FOR INSTALL SOUND AND COMMERCIAL AUDIO APPLICATIONS ENG

Think you know Lab.gruppen? Think again.

VUE al-4 Subcompact Line Array System -4 Acoustic Element & V4 Systems Engine Specification Sheet A Whole New World Of Possibilities lim Da ina

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

Specifications XPA 2002, XPA 2003, XPA 2004 Series

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

AUD-220 Installation Guide

MASELEC MTC-6 master transfer and monitor system

E1 controller module switches

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

Host Controller: HST-4002

Supplemental to New Product Information (SNPI)

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

I/O Interfaces. 24 Input Stage Box with 24 MIDAS Microphone Preamplifiers

P100 Wireless Player.

DL806. Digital Live Sound Mixer with ipad Control

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

DATA SHEET TESIRAFORTÉ DAN AI

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

REDCAT ACCESS DETAILED SPECIFICATIONS

Version 1.1b December AVB32-ES User s Manual AuviTran

Savant Host: HST-4501

NetLinx NX Integrated Controller NX-3200 (FG )

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

I/O Interfaces. 48 Input, 16 Output Stage Box with 48 MIDAS Microphone Preamplifiers

DP b-DI. ID24t ID24i. User Manual

QM-AE1. QuickMedia Audio Extractor

Contents. Introduction 3. Controls and functions 8. Setup 10. Reference 39. Panel Operation 12

AMP100 AMP102 AMP110 AMP210 AMP310

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

MODEL 805 USER MANUAL

Copyright 2018 Xi'an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

FreeSpace Amplifiers. Premium commercial amplifiers designed to enhance audio installations using Bose FreeSpace loudspeakers.

DATA SHEET DEVIO SCR-20 CONFERENCING HUB

INT-HD52 Quick Install Guide

Savant Call Server: SCS-3000

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

NetLinx NX Integrated Controller NX-2200 (FG )

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

Overview. Features. Technical Data Sheet 1 / 6. Digital Mixer TF-RACK

USER'S MANUAL ENGLISH

A360 DESIGN GUIDE. This design reference provides guidance on designing Aviom personal mixing systems with the new A360.

APEX ARRAY APEX 28HA / APEX 18SA

PXR 1506 / WATT MIXER AMPLIFIER

CS-1 Active Full Range Integrated Commercial Audiovisual System

Data sheet AT-35 active. Arc-Series Architectural Sound Design.

ACCESS LINK DETAILED SPECIFICATIONS

LA4 AMPLIFIED CONTROLLER

PRe3. Two Channel Analog Pre-Amplifier

Jadis I-35. Owner's Manual. Integrated amplifier

AUD-340 Installation Guide

User Guide. Target System Power Amplifier Module

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

DCN23 Digital Crossover with 2 inputs and 3 outputs

PRe6. Multi-Channel Analog Pre-Amplifier

Coolback II way Active Mono Amplifier

MG12XU Overview Features Technical Data Sheet

Owner s manual. SDAI 2175 Semi Digital Amplifier Integrated

User Guide PRNT

KD-AMP220. Operating Instructions. 2 Channel 20 Watt Per Channel, Compact Digital Audio Amplifier

Overview. Features. Technical Data Sheet 1 / 6. Digital Mixing Console TF1

Digital Output. 1 A-Net Out; RJ45 connector TRS Inputs. Digital Input. 1 A-Net In; RJ45 connector TRS Thru. A-Net Pro16e Slots.

Manufactured by: Audio-Technica Corp Nishi-naruse, Machida, Tokyo , Japan Tel.: Fax:

Orchestra Orchestra reference

DELL EMC VPLEX FAMILY

The StudioLive 18sAI is the

PDU - Overview / Non-Intelligent PDU s

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Transcription:

NEXO S. A. Parc D Activité du Pré de la Dame Jeanne B.P. 5 60128 PLAILLY France Tel: +33 (0)3 44 99 00 70 Fax: +33 (0)3 44 99 00 30 Email: info@nexo.fr NEXO LatAM Tel: +1 305 677 9322 Fax: +1 360 234 7870 Email: info@nexo.fr NEXO Asia GPO Box 806 Hong Kong SAR China Tel: +852 9096 3472 Fax: +852 2104 3214 Email: info@nexo.fr www.nexo.fr

NUAR Universal Amp Rack www.nexo.fr

NEXO Universal Amp Rack 2

Intelligent amplification for all NEXO speaker systems. The NEXO Universal Amp Rack (NUAR) provides NEXO users with a scalable, plug & play, amplified audio distribution solution of unrivalled power and flexibility. Systems of any size can be configured easily using channel by channel preset selection of any NEXO cabinet, and digital output patching. The NUAR rack comprises a pair of NEXO NXAMP4X4 amplifiers, twin DMU digital input metering devices, a pair of DPU digital output patching devices and a choice of 110V, 220V or dual-voltage mains distribution boxes providing power to all the components in the rack. System configuration is simple, using either ESMonitor the new NEXO NeMo ipad app. NEXO cabinet presets are selected on a channel by channel basis, with selected cabinet names displayed by the DPU for easy output patching. Digital input metering is provided by the DMU, clearly indicating the presence and status of input signals, including network inputs. ESMonitor now accommodates NXAMP s channel by channel preset selection. An entirely new library of presets for every single cabinet in the NEXO range delivers linear phase across any system, making it possible to mix and match NEXO cabinets. Increased efficiency and versatility is inherent in NUAR s mechanical design. The 14U chassis is suspended within a robust rack case, featuring two sliding doors and an integrated rigging system. This enables up to 3 racks to be flown using an optional bumper and the easy attaching/detaching of a wheelboard. Each NUAR is fully configured and tested at NEXO to provide a truly versatile and tailored Plug & Play amplification solution. 110V, 220V or dual-voltage power distribution NUAR can be configured with a choice of 110V, 220V or dual-voltage power distribution boxes, allowing the user to achieve the optimum balance of versatility and cost efficiency. Where necessary, the power distribution boxes feature colour-coding to assist power balancing when using three phase supplies. The colour-coding is also labelled on the rack case. 220V power box 110V power box Dual-voltage power box 3

NEXO Universal Amp Rack The complete integration of power and control. NXAMP4x4 Powered TDController Among the most powerful amplifiers in the industry, the NXAMP4X4 integrates command, control, amplification and protection functions within a relatively light weight and space-saving 4U rack. By combining realtime monitoring of temperature, voltage and current with powerful dual-dsp control, the NXAMP4X4 achieves exceptional performance with a high degree of protection for both amplifier and power supply, while simultaneously offering all control parameters required for the speakers. The latest firmware load enables channel by channel preset selection for any speaker in the NEXO range. The result of a 2 year development programme, all presets have been revised using FIR filtering to ensure linear phase across any combination of NEXO cabinets, making it possible to mix and match cabinets in a single, coherent system. EtherSound and Dante digital networking cards can be installed. Latest generation 24-bit audio converters provide enhanced dynamic range with low latency (500us analogue input to output in flat mode), eliminating the need for external A/D conversion. Improved power efficiency and decreased heat generation comes courtesy of four separate Switch Mode Power Supplies, which ensure high power capacity with low load drive. NEXO amplification technology delivers maximum efficiency in drive performance and power, while providing the audio quality of traditional class AB amplifiers with the heat dissipation of class D amplifiers. This results in a 50% reduction in power consumption, contributing to outstanding sound quality. Converters operate synchronised in the opposite phase, thus cancelling noise. The NXAMP4X4 delivers 4 x 4000W into 2 Ohm loads, and is available in 110V, 220V and dualvoltage versions. Latest Firmware Features Set up selection per channel Linear phase on all set-ups All systems compatible 20Hz-20kHz Selectable crossover points for subs 4

5

NEXO Universal Amp Rack DPU Automated output patching The DPU is designed to optimise use of the NXAMP s channel by channel preset selection by automatically routing its outputs to any of 6 output connectors on the DPU front panel. Cabinet names and bridging status are displayed alongside each output, making it easy to wire the system. Security is assured by fully redundant power supplies and dual switching. When connecting DPU to the NXAMP, a routine first checks that the power from the amplifier is coming from the correct channel. If communication is lost with the NXAMP, the DPU retains its configuration until contact is resumed. Key Features Intelligent output patch panel offering digital communication with NXAMPs. Provides automatic output speakons wiring regarding the configuration of the NXAMP. Four individual LCD displays for easy labelling of the output speakons. Fully redundant design for maximum safety, including dual power socket and dual universal power supplies. Plug and play operation, entirely driven by the host NXAMP. DMU Intelligent input patching and metering DMU is the ultimate tool for the easy monitoring of any activity on the NXAMP audio inputs. The DMU is totally driven by the host NXAMP, with signal and power supply coming from the NXAMP s GPIO port. Front panel features include 4 analogue XLR inputs plus links, three RJ45 ports for digital audio networking and LED VU meters. Particular care has been taken to ensure minimum insertion losses in the analogue audio signal. Key Features Intelligent input patch panel offering digital communication with NXAMPs. Provides input level meters on all analogue and network inputs. Fully passive design on the audio and network paths. Powered through the host NXAMP, no need for mains supply. 6

Digital audio networking NUAR racks can be pre-configured with EtherSound or Dante digital audio networking capabilities, enabling users to monitor and control the NXAMPs. NXES104 EtherSound TM Network Card NXDT104 Dante TM Network Card Key Features Extracts 4 audio streams (24 bits / 48 KHz) among the 2 x 64 channels of a ES100 Ethersound TM stream. IN and OUT port for simple daisy chain without any need for an external switch. 3rd Ethernet port for remote control of the whole network from any NXES104 card and ASIO streaming. Key Features Receives 4 audio streams (24 bits / 48 KHz) in Dante TM format. Unique 3-port design can be used: - As an integrated 3 port gigabit switch - As two Dante redundant port plus an optional 3rd port for additional remote control Direct connection to PC using the ASIO format. NeMo Remote Monitoring App Available free for ipad and iphone, NEXO s NeMo Remote Monitoring app provides remote control over a NXAMP network from anywhere in the venue. Key Features Visualise the NXAMP network on a 2D map Monitor and control the parameters of one or more devices, including: - input levels - output levels - patching between outputs and inputs - output parameters such as volume, gain, delay, array-eq and headroom - device and channel mute and solo - setups - scenes 7

NEXO Universal Amp Rack NUAR power illustrations Central to the concept of the NUAR rack is the versatility to configure and power any combination of NEXO cabinets. Here are just a few systems that serve to illustrate the sheer power of NUAR. 32 x GEO S12 cabinets powered by a single NUAR rack. 24 x 45 N12 monitors powered by a single NUAR rack. 12 x M46 main and 12 x B112 bass STM cabinets powered by a pair of NUAR racks. 8

NUAR accessories NUAR Bumper NUAR incorporates an integral rigging system. Up to three racks can be flown using the optional bumper. NUAR Wheelboard Each NUAR rack is supplied with a wheelboard which can be attached and detached using NUAR s integral rigging system. Dimensions 9

NEXO Universal Amp Rack NUAR - Packing List Specifications - NXAMP4x4 EACH NUAR RACK COMPRISES: 1 X ASD14U + removable wheelboard 2 x NXAMP4x4 Power Amplifier (110V, 220V or 110V/220V) 2 x DMU Digital Meter Unit 2 x DPU Digital Patching Unit 1 x Power Box (110V, 220V or 110V/220V) 2 x 4U NEXO perforated panels 3 x 2U NEXO perforated panels 2 x DB25 cords 2 x DB9 cords 4 x SPEAKONS 4*2.5mm² power cords 8 x XLR/XLR cords 4 x 250V/10A power cords 6 x RJ45 cords Optional Digital Audio Networking Cards 2 x EtherSound cards or 2 x DANTE cards Optional Rigging Bumper includes: 1 x NUAR_BUMP 2 x 10 x 60mm heavy duty ball lock with + retaining cables 1 x 5/8 shackle MECHANICAL DATA NUAR Dimensions (H D W with board Wheel): 889mm (14U) x 663mm x 600mm Weight (all devices + board wheels): 133kg (293.2 lbs) Finish: Heavy duty black 900 vinyl cover NUAR_BUMP Dimensions (H D W): 60mm x 150mm x 600mm Features: includes 1 x 5/8'' shackle, 2 x 10 x 60mm Ball Locks with cables Weight: 6kg (13.2 lbs) Finish: Black 900, sanded paint Max Load: 450Kg up to 3 NUAR Specifications - Power Distribution Boxes TECHNICAL DATA POWER SPECIFICATIONS FOR NXAMP4x4 Number of channels Max. output voltage (no load) Max. output power (4 channels mode /8 Ohms load per channel) Max. output power (4 channels mode /4 Ohms load per channel) Max. output power (4 channels mode /2 Ohms load per channel) Max. output power (2 channels mode /8 Ohms load per channel) Max. output power (2 channels mode /4 Ohms load per channel) Power consumption (Standby) Power consumption (Idle) INPUT TO POWER OUT SPECIFICATIONS Frequency response Input impedance / Max. level Dynamic range / TDH + N Latency A to D Converters Processing BACK PANEL FEATURES Analog audio inputs Power outputs RS232 port GPIO port Expansion slot Mains sockets USER INTERFACE AND CONTROLS Front panel buttons and knobs Display Global status display Speakers/Amp status display DIMENSIONS AND CERTIFICATIONS Dimensions Weight Electrical Safety Certification EMC Certification Green status 4x amplifiers channels, 2 by 2 bridgeable 4x 200 Volts 4x 1900 Watts 4x 3400 Watts 4x 4000 Watts 2x 6800 Watts 2x 8000 Watts 20 Watts 120 Watts +0.5 db from 10 Hz to 20 KHz 20 K / +28 dbu 105 db unweighted / Typical 0.1% on a flat setup 500 us on a flat setup Audio and current/voltage sense lines : 24 bits @ 48 KHz Two dual-core 24 bits fixed point DSP with 56 bits accumulator 4x balanced analogue inputs on XLR3 with a second XLR3 for link 4x Neutrik Speakon NL-4 outputs 1x DB-9 connector for firmware upgrade and accessories connection 1x DB-25 connector with 5x Global Purpose Inputs and 8x Global Purpose Outputs For networking audio cards, 4x digital audio inputs and remote control 2x Neutrik Powercon NAC3 (2x 16 A) or NAC3-HC (2x 32 A) depending on model On/Off Mains switch, Select Wheel, 2x Menus buttons, 4x Select and 4x Mute buttons 40 characters by 2 lines LCD display with LED backlight. Power, Standby and Amp Protect LEDs. Per channel, output current sensing, speaker protection and channel soft clip. 4U 19" Rack - 457 mm (18") Depth 24.5 Kg (49 lbs) net cetlus, CB (CE) CE, FCC Compliant with ROHS directive MD1, 110V POWERBOX Dimensions (H D W): 80mm (2U) x 350mm x 482mm Input: 2 x 30A L14-30 NEMA Connectors Weight: 7.8Kg (17.1lbs) Outputs 4 x 4" Tails 14 cable, terminating with NA3FCA POWERCON 4 x IEC 10A + locks for auxiliary Finish: Heavy duty black 900 sanded paint Protection: 2 x 10A circuit breakers for Auxiliary Output MD2, 220V POWERBOX Dimensions (H D W): 80mm (2U) x 380mm x 482mm Weight: 6.9Kg (15.2lbs) Input: 32A P17, 3P + N +G Outputs 4 x 4"Tails cable, terminating with NA3FC-HC POWERCON 4 x IEC 10A + locks for auxiliary Finish: heavy duty black 900 sanded paint Protection 4 x 16A breakers C type for POWERCON Output 2 x 5A circuit breakers for Auxiliary Output Dual-voltage POWERBOX Dimensions (H D W): 80mm (2U) x 380mm x 482mm Weight :14.7Kg (32.4lbs) Input: 1x 32A P17, 3P + N +G 2 x 30A L14-30 NEMA Connectors Outputs 4 x 4" Tails cable, terminating with NA3FC-HC POWERCON 4 x IEC 10A + locks for auxiliary 4 x 4" Tails 14 cable, terminating with NA3FCA POWERCON 4 x IEC 10A + locks for auxiliary Finish: heavy duty black 900 sanded paint Protection 4 x 16A breakers C type for POWERCON Output 2 x 5A circuit breakers for Auxiliary Output 2 x 10A circuit breakers for Auxiliary Output 10

Specifications - NETWORK FORMAT Compatible networks Ethersound networks Dante networks Network type Dedicated Ethernet 100 Mb TCP/IP over Ethernet, 100 Mb or 1 Gb Device addressing Automatic, based on Mac address Automatic, based on IP address with Zeroconf AUDIO FORMAT Number of channels 4 channels from network to NXAMP 4 channels from network to NXAMP Resolution / Sample Rate 24 bits / 48 KHz 24 bits / 48 KHz Latency 0.10 ms 0.15 ms to 5.0 ms (typical 1 ms) FRONT PANEL FEATURES Network inputs 2 shielded Neutrik Ethercon 2 shielded Neutrik Ethercon Additional port RJ45 for additional remote control RJ45 for additional remote control LEDs on network ports Tx and Rx on each port Link/Act and Speed on each port LEDs on additional port Link and activity Link and activity GENERAL SPECIFICATIONS NXES104 NXDT104 Power supply + 3.3 Volts, 5 W from NEXO slot + 3.3 Volts, 7 W from NEXO slot Dimensions (W x D x H) 120 x 160 x 40 mm (NXAMP slot) 120 x 160 x 40 mm (NXAMP slot) Weight 160 g 200 g EMC certification CE, FCC, ICES CE, FCC, ICES Green Status ROHS and REACH ROHS and REACH Specifications - DPU ROUTING FEATURES Routing Matrix FRONT PANEL FEATURES Power outputs LCD Displays BACK PANEL FEATURES NXAMP power inputs NXAMP interface Mains inputs GENERAL SPECIFICATIONS Power supply Dimensions Weight Electrical Safety Certification EMC Certification Green status Route any of the four input channels to one or several Speakon pins pairs on the front 4 Neutrik Speakon-4 and 2 Neutrik Speakon-8 4 LCD displays, 2 x 8 characters 2 Neutrik Speakon-4 for connecting the NXAMP Powered TDcontroller RS232 interface for communication with the NXAMP Powered TDcontroller 2 IEC connectors with security latch (V-Lock system) Fully redundant, dual universal 100 ~ 240 Volts, 50 or 60 Hz, 25 Watts 1U 19" Rack - 248 mm (10") Depth 4.7 Kg (10.4 lbs) net cetlus, CB (CE) CE, FCC Compliant with ROHS directive Specifications - DMU METER FEATURES Integrated VU-meters Network activity FRONT PANEL FEATURES 8 channels of 8 levels VU-meters, one per input (4 x Analog and 4 x Network) 2 LEDs per network input Analog audio connectors 4 x Neutrik XLR-3 with parallel output link on XLR-3, named from A to D Network connectors 3 x Neutrik Ethercon connectors, named from 1 to 3 BACK PANEL FEATURES Analog audio connectors Network connectors GPIO connector GENERAL SPECIFICATIONS Power supply Dimensions Weight Electrical Safety Certification EMC Certification Green status 4 x Neutrik XLR-3 passive connection to front panel XLR 3 x RJ45 connectors, routed to front panel through matched impedance pairs DB-25 for digital communication and power from host NXAMP From GPIO port, 5 Volts DC, 1Watts 1U 19" Rack - 50 mm (2") Depth 1.2 Kg (2.6 lbs) net. cetlus, CB (CE) CE, FCC Compliant with ROHS directive ipad and iphone are registered trademarks of Apple Inc. All other trademarks are properties of their respective owners. 11