Regional Seminar Series. Critical Facilities, Data Center,& IT

Similar documents
Regional Seminar Series Orlando. Critical Facilities Update

OSIsoft PI System Usage For Academia

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

PI System Transforms NIH Central Utility Plant (CUP) Operations

Driving Proactive Facility Operations with Automated HVAC Diagnostics

O&M Roadie or Rockstar?

ROI CASE STUDY MAY Logicalis Achieves 159% ROI* with CA DCIM Solution

Energy Action Plan 2015

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

HVAC Energy Management System

Improving Situational Awareness for Utilities Operators and Energy Managers

Data Center Infrastructure Management (DCIM) Demystified

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

Let s Build a Smarter Planet:

Leveraging Building Automation Systems to support ongoing commissioning

About Schneider Electric

Session 6: Data Center Energy Management Strategies

MSYS 4480 AC Systems Winter 2015

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

Final Benchmarking Policy and Procedures

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Trailblazer AGZ-E air-cooled scroll chillers

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Measurement and Management Technologies (MMT)

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

Sustainable Facility Design for Collaborative Research and Development

PI Software Usage. Scott Minter, Director, IT Mitsubishi Power Systems Americas, Inc. Copyright 2010, OSIsoft LLC. All rights reserved.

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

Why and How to Benchmark Building Energy Use in Office Buildings

Factsheet. Power Generation Service Energy efficiency in power generation and water

Building Management Solutions. for Data Centers and Mission Critical Facilities

IDEA Campus Energy UNIVERSITY OF MARYLAND Securing Our Networked Utility Infrastructure

IBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013

District Cooling Marches on in Dubai The Emirates Towers Case Study

Prediction of Chilled Water Plant Failures and System Optimization Using Multivariate Modeling Techniques

multi-utility metering a total systems approach

Mission Critical Facilities and Data Center Operations

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

a) Provision of a chilled water supply b) Provision of electric power supply and other fuels

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Silicon Valley Power Data Center Program Rebate Application

Using the PI System For Real-Time Energy Management at NASA Langley Research Center

The Energy. David L. Moss Dell Data Center Infrastructure

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

Green IT: reduce energy costs and improve service levels with virtualization Bob Good, Manager - Systems Engineers August 2009 MISA Fall Conference

Comprehensive Energy Management & Utility Master Plan

Kako optimizovati operativni rad data

2018 NETGEAR Sustainability Report

Construct Chiller Plant, Phase I

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

GE Digital Energy. imagination at work

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

APPENDIX E: DRAFT INITIAL STUDY/MITIGATED NEGATIVE DECLARATION COMMENT LETTERS AND RESPONSES

Energy Analytics Solutions

Seeing Clearly in the New Reality

SmartStruxure Lite Solution Get control. Get efficient. Get value. Integrated small- to medium-sized building management

ARTO LIND ABB Ability Datacenter Automation. The way to monitor & control your DC infrastructure (DCIM) Datacenter Infrastructure Management

Modius OpenData v3.3. Product Overview of Modius OpenData for Unified Data Center Monitoring & Analysis

Cisco s Green Story. Connected Urban Development

Wednesday, September 21. New Trends in Submetering of Commercial, Institutional and Industrial Properties. Mike Easton

How vxchnge Centralized its Operations with the PI System and Datacenter Clarity LC

Green Data Centers A Guideline

Predictive Software for Facilities Management

Saving Energy and Reducing Costs Through Better Use of Building Automation Systems

Revenue Management as a Customer Service. Ed Hackney

LEADERS IN MEP, COMMISSIONING & ICT FOR BOSTON AND THE NORTHEAST

Cooling Solutions & Considerations for High Performance Computers

How Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Green IT and Green DC

where we are, where we could be, how we can get there. 12/14/2011

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Annual Report for the Utility Savings Initiative

Data Center Infrastructure Management ( DCiM )

Cisco EnergyWise Optimize and Cost Saving. Traditional IT Power Management

Beverly D. Grappone Hall Certified LEED Silver Home of NHTI s State-of-the Art Nursing Simulation Center

The simplicity of integrating HVAC&R machines into BMS architectures

CENTRAL PLANT OPTIMIZATION. The heart of building efficiency

Must possess Universal EPA Section 608 certification; OR Type I AND Type II EPA Section 608 certification.

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Connectivity from A to Z Roadmap for PI Connectors and PI Interfaces

CLICK TO EDIT MASTER TITLE STYLE. AdvanTEC Solutions CHILLER PLANT HEALTH MANAGER

BICSI CECs (Continuing Education Credits) for : Trends in Energy Reduction Initiatives How IT Helps Change the Game

Trane Controls. Smart Solutions for Smart Buildings

Green Computing and Sustainability

Energy Efficient Data Centers

BAS Chillers 8/15/2016. Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August 10, 2016

Company information PROTEC Facility Solutions PROTEC GmbH » Established: *» General Manager: Ralf Wogawa

PROSPECTUS ALTERATION PHILLIP BURTON FEDERAL BUILDING & U.S. COURTHOUSE SAN FRANCISCO, CA

Energy Performance Contracting

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

Communicating Submeter Data Via BACnet

Transcription:

Regional Seminar Series Critical Facilities, Data Center,& IT Mike Mihuc, Regional Manager Northeast, OSIsoft Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

State of Market Need to reduce costs Public requirement to promote sustainable policies Data centers are running out of capacity Potential Federal and State regulations 2 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

Expand your PI for the infrastructure Lines of Business/ Operations IT Infrastructure Data Center Infrastructure Did you know PI can be applied to these infrastructure s for great value Facility Infrastructure 3 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

Some Example Customers Facility Customers Data Center Customers 4 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

PI at Eastman Kodak Kodak Park facts Area>20,000,000 Square Feet 11,000 Employees Operates its own Fire Department Operates its own rail road Performs its own water and waste water treatment Operates 2 power plants Benefits >$10MM! Measurements 600 Electric Distribution Meters 600 Additional Distribution Meters for Steam, Chilled water, Brine, Compressed air, Process water, Nitrogen, Natural gas etc. Significant Metering Used within the Power Houses to Manage the Generation Side 5 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

Energy Consumption Efficient Devices and Installation Optimized use via automation Why PI FOR Energy Management 100% 70% Up to 8% per year is lost without monitoring and maintenance program Monitoring & Maintenance Time 6 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

What levels will PI Connect ENTERPRISE Business Systems Portal Servers Application Servers Measurement ID M1 M2 M3 Description Utility Provider Total Power Load Measurement Power Load for Non-critical systems (lighting, Joint Ventures offices, etc.) Employees Regulatory Agencies Power Load for HVAC and Other Mechanical Systems M4 Total Power Load for Devices and Other Critical Systems Division HQ s M5 M6 Cooling Tower Load Chiller, Air Handler Load M7 CRAC Unit Load M8 UPS Load Measurements MFG Sites Data Center M9 Pole, Circuit and Rack Loads M10 IT Asset 7 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

PI at University of Rochester System Components OSIsoft PI System captures data from all meters, plant control system, and building automation systems Revenue Meter Interface Plant Control System & Meters Building submeters Building automation systems Network Measurements Hot water meters Electric meters (including HV substations) Assorted gas, oil & other meters Chilled water meters Steam meters 8 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

Get Started today-add Value to the PI investment Engage with OSIsoft for understanding how Expand the use of PI For IT How to Utilize: MCN Health Monitor PI for IT Monitoring Expand the use of PI for Critical Facilities How to Utilize Add- PI Interfaces BACnet, Modbus, OPC Take advantage of Benefits "While metering alone does not save energy, the information from the meters, when acted on, can result in significant reductions typically 5 to 15 percent" Jean Lupinacci, Director, Commercial and Industrial Branch of Energy Star U.S. Environmental Protection Agency (EPA) 9 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

PI expansion update- see for yourself UC Davis http://facilities.ucdavis.edu/dashboard/ Queen s University http://livebuilding.queensu.ca/ Rochester University http://meters.energy.rochester.edu/rc%20sharepoint%20files/hutch%20hall%20electric.aspx 2009 User Conference Critical Facilities Track - Industry Observations and Trends (David Jump, Quantum Energy) - PPT The Daily Miracle of Internet Connectivity (PI Data Centers) (Greg Dumas, DST Controls, Ernest Holloway, Pamela Brigham, Equinix) - PPT Real time Data for Data Center and Lab Energy Efficiency (Chris Nolan, Cisco Systems, Ken Morikawa, OSIsoft) - PPT The Data Center Dashboard (Steven Berkovich, Teresa Tung, Accenture) - PPT Understand How PI is being used at Microsoft in the 10min. Wrap (Scott Mauvais, Microsoft Technology Center) - PPT 10 Empowering Business in Real Time. Copyright 2009, OSIsoft Inc. All rights Reserved.

Thank you Copyright 2009 OSIsoft, Inc. 777 Davis St., Suite 250 San Leandro, CA 94577