C.A. Unicenter Integration User s Manual

Similar documents
Insight Mgr 7 Integration User s Guide

Systems Insight Manager 4 and 5 Integration User s Guide

HP OpenView HP-UX Integration

Mupgrade Utility. Minislot Transverse For Network Management Card User Manual

Fluke Networks OptiView Integration for Unicenter NSM. Getting Started Guide. Revision: 2

CentreWare for Unicenter TNG User Guide Your Autopilot to Productive Printing

ehealth SPECTRUM Integration

OptoAgent Integration for Unicenter Network and Systems Management 3.1. Getting Started Form

Eaton Intelligent Power Manager User s Guide / AB. Eaton Intelligent Power Manager User s Guide

Using the Prime Performance Manager Web Interface

ehealth SPECTRUM Integration

Xerox CentreWare for Tivoli NetView Users Guide Version 1.1.8

CA Unicenter NSM Agent

Xerox CentreWare for HP OpenView NNM Users Guide Version 1.5

This document provides the following information:

HP Toptools 5.5 for Unicenter TNG. User Guide

Integration with Network Management Systems. Network Management System (NMS) Integration

Minislot Transverse Environment Sensor 66846

KYOCERA Net Admin User Guide

Network Management Card. User Manual

SVA NMP Monitor for Unicenter TNG on Windows NT/2000

ForeScout CounterACT Resiliency Solutions

NEC Express5800 Series NEC ESMPRO Manager User's Guide

HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

ehealth Integration for HP OpenView User Guide

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software. Polled Network Elements

Accessing Data from the Web Interface

SmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS)

Configuring Traps for XOS/AOS Switches

EMC ControlCenter INTEGRATION PACKAGES PRODUCT GUIDE. 5.2 Service Pack 5 P/N REV A01

Xerox CentreWare for HP OpenView NNM User Guide. Version 1.1

Application Notes for NetIQ Vivinet Diagnostics 2.3 with Avaya Communication Server 1000 Release 7.5 Issue 1.0

PowerJUMP DataShield

Discover your Network

Getting Started with Notifications

Managing the Web Interface

CA ehealth Integration for HP OpenView

Lite Management Console. design overview Rev. 1.0 December 4, 2003 nextedge Technology, Inc.

SNMP Agent Setup. Simple Network Management Protocol Support. SNMP Basics

Online Help StruxureWare Data Center Expert

Network Management Utility

SVA NMP Monitor for Unicenter TNG on Windows NT/2000

URL for staff interface (bookmark this address on staff computers):

OpenManage Integration for VMware vcenter Quick Install Guide for vsphere Client, Version 2.3.1

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0

LifeSize Control Installation Guide

FieldView. Management Suite

Configure SNMP. Understand SNMP. This chapter explains Simple Network Management Protocol (SNMP) as implemented by Cisco NCS 4000 series.

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418

SPECTRUM. Multicast Manager User Guide (5132) r9.0

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:

OpenManage Integration for VMware vcenter Quick Install Guide for vsphere Client, Version 2.3

integrating NonStop servers with hp OpenView using SNMP

Mobility Services CAS. wips CHAPTER

Firmware Revision History and Upgrade Instructions

Using Integration Utility

NNMI140 - Network Node Manager i Software 9.x for Operators

MIB Browser Version 10 User Guide

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software SmartView TM EMS. Polled Network Elements

ShutdownAgent 2012 User Manual

Nortel Unified Communications Management. Fundamentals. Release: 1.0 Document Revision: NN

OnCommand Unified Manager

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Avocent Universal Management Gateway Appliance Plug-in for Avocent DSView 4.5 Management Software Release Notes Version

NeuralStar Installation Guide

HP0-Y13. ProCurve Network Management. Download Full Version :

AlliedView -EMS DEVICE MANAGER USER S GUIDE

Wavecrest Certificate SHA-512

CA ehealth and CA SPECTRUM

Dell Lifecycle Controller Integration Version 2.2 For Microsoft System Center Configuration Manager User's Guide

OpenManage Integration for VMware vcenter for Desktop Client User's Guide Version 3.1

ManageUPS DCU DISCOVERY AND CONFIGURATION UTILITY. Quick Start Guide

DPoE Element Manager. Release Notes

Configure Controller and AP Settings

Dell Lifecycle Controller Integration Version 3.0 For Microsoft System Center Configuration Manager User's Guide

Management Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements

STS Web card for Upsilon/Epsilon STS (66073) STS Web card User Manual

Veritas NetBackup Read This First Guide for Secure Communications

Read the following information carefully, before you begin an upgrade.

HP Network Node Manager 9: Getting Started. Manage your network effectively with NNMi. Marius Vilemaitis. J enterprise PUBLISHING MUMBAI BIRMINGHAM

Network Management Card. User Manual

1) Release Summary...1 2) Platforms Supported...3 3) Installation Notes...3 4) Important Notes and Known Limitations...5 5) Uninstallation Notes...

Industrial Ethernet Products Management Utility

User s Guide. Duralink Server Manager

Chapter 3 Managing System Settings

Eaton Intelligent. User s Guide. Eaton Intelligent Power Manager User s Guide / AE

Web Browser Application Troubleshooting Guide. Table of Contents

Version 6.0 October P Xerox CentreWare Web. Installation Guide

BSQUARE Corporation. Remote Device Administrator for use with the IBM NetVista N2200w. User s Manual. Version 1.0

Symbols INDEX > 12-14

Audit Reports. Change Audit Reports CHAPTER

Reference. Base Configuration Updates

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline

Product Support Notice

Maintenance Release is an accumulative maintenance release. That is, all CRs fixed in previous releases are included.

BROWSER-BASED SUPPORT CONSOLE USER S GUIDE. 31 January 2017

SPECTRUM Integration for CA Unicenter NSM

flyf InfraStruxure Operations PRO Pack InfraStruxure Operations PRO Pack

Configuring Communication Services

Transcription:

C.A. Unicenter Integration User s Manual Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 1/9

Table of Contents 1 Introduction...3 2 Installation and configuration procedure...3 2.1 Installation procedure...3 2.2 Configure Unicenter security...3 2.3 Configure EATON SNMP cards/agents...4 3 Uninstalling the agent...4 4 Use...5 4.1 EATON Automatic discovery (Auto-Discovery)...5 4.2 Receive and view UPS alarms...7 4.3 Launching UPS properties from Unicenter...8 4.4 EATON equipment and Unicenter compatibility list:...9 Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 2/9

1 Introduction This document describes the stages to integrate and use an EATON UPS with the Computer Associates Unicenter Network and Systems Management platform. This document is applicable for Unicenter version 3.0. To use any EATON UPS with this platform, you must have completed the installation and configuration procedures first. 2 Installation and configuration procedure 2.1 Installation procedure 1. Execute the "ca_unicenter_integration_vxx.exe" InstallShield package. The following actions will be automatically performed: Copy both MIB and Icon files. Compile and load the MIB. Install the UPS class (you have to select the appropriate repository). Load Message Management for Events and Actions. Modify Unicenter configuration files (nodes.dat, ip.atp and gwclass.dat). Original files will be saved with xxx.yyy.eaton extension. Reset the Unicenter DSM after user confirmation. This operation takes several minutes because all Unicenter services need to be restarted. This step is necessary to finalize the package integration. 2. Configure Unicenter security for managing events and actions (described in the following section 2.2). 3. Configure SNMP cards/agents (described in the following section 2.3). 4. Perform auto-discovery to detect UPS SNMP cards/agents. 5. Start the Unicenter Explorer and the Event Management console to detect UPS status changes. 2.2 Configure Unicenter security To manage the UPS icon status, a few commands must be executed from the EM console with the relevant administration rights. EM default settings only authorize the "caunint" user to perform commands. Follow the instructions below to enable the proper settings: 1. From the command line DOS, execute "caugui settings". 2. Click on the "Event management" major tab and then on the "Client Preferences" minor tab. 3. Change the "Users authorized to issue commands" field to "*@*". 4. Save the settings. 5. From the command line DOS, run "unicntrl stop opr" then "unicntrl start opr". Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 3/9

2.3 Configure SNMP cards/agents Each SNMP card or agent must be configured so that the SNMP alarms (Traps) are sent to the Unicenter platform. To do this, the Unicenter host must be declared in the managers table of each SNMP card and agent. For this configuration, you can use the cards web interface. For legacy cards (66074, ), run the Set SNMP Manager.bat script file in <Unicenter home path>\bin directory and follow the instructions. During the procedure, you will be asked for: The IP address of your SNMP card or agent, The IP address of the Unicenter host, The read/write community name for the agent (by default "public" if not specified), The trap receiver community name (by default "public" if not specified). Repeat these steps for each SNMP card or agent. NOTE: You also have other possibilities: 1. For SNMP cards, you can use telnet configuration menu. You can also use the HTML settings page for the "Manager Table" settings. 2. Use a MIB browser to configure the SNMP cards and agents. However, we strongly suggest using the script file as these operations require an in-depth knowledge of the SNMP protocol and also a good understanding of our products. Configuration example for manager number X: OID number Designation / Value 1.3.6.1.4.1.705.1.2.2.1.1.X Manager number = X. 1.3.6.1.4.1.705.1.2.2.1.2.X Device number = 0. 1.3.6.1.4.1.705.1.2.2.1.3.X Manager type = 9 (other). 1.3.6.1.4.1.705.1.2.2.1.4.X Protocol level = 4 (snmpv1). 1.3.6.1.4.1.705.1.2.2.1.5.X Manager description = "Unicenter" for example. 1.3.6.1.4.1.705.1.2.2.1.6.X Manager IP address = YYY.YYY.YYY.YYY format. 1.3.6.1.4.1.705.1.2.2.1.7.X Community name = "public" for example. 1.3.6.1.4.1.705.1.2.2.1.8.X Severity level = 2 for example. 1.3.6.1.4.1.705.1.2.2.1.9.X Acknoledgement type = 2 (mgnoack). 3 Uninstalling the agent From the "Add/Remove programs" item of the control panel, execute "Unicenter UPS Device Integration Package". This script will perform the following actions: Stop services. Unload the MIB. Remove both icon and MIB files. Remove the class and objects from World View CORE (select the appropriate repository). Remove the Event Message records and actions. Restore Unicenter configuration files (nodes.dat, ip.atp and gwclass.dat). Reset the Unicenter DSM after user confirmation. This operation takes several minutes because all Unicenter services need to be restarted. This step is necessary to terminate uninstallation. Important Notes: During restoration of the Unicenter configuration files, a backup copy of the current files will be made in their respective directories with the xxx.eaton extension. It is recommended to compare each configuration file with its copy and merge modifications after uninstallation. Restoring a file from its saved copy could erase modifications. Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 4/9

4 Use 4.1 UPS Automatic discovery (Auto-Discovery) Any EATON Pulsar UPS with a compatible SNMP card or SNMP proxy agent is automatically discovered by Unicenter. Each detected UPS is identified by its IP address. Several maps are available: Unicenter Explorer: Topology" or "Unicenter 2-D map": View any equipment from a network segment. Unicenter Explorer: Class specification": View all the UPS detected on the network. Network segment map containing a UPS. Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 5/9

View the EATON UPS equipment detected on the network (MGE_UPS Class). Note: MGE_UPS belong to the UPS Class. With "Unicenter 2-D map", each UPS is associated with a specific icon for easy network identification. UPS through "Unicenter 2-D map"view. Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 6/9

4.2 Receive and view UPS alarms The icon is associated with the UPS status (depending on the alarms received) UPS Status Unicenter 2-D map Unicenter Explorer Normal Warning Critical Using EM Console, you can view the traps received from any equipment. A text message is associated with each trap (alarm or acknowledgement) sent by a UPS. The color depends on the alarm severity: Green: Normal status (Alarm Acknowledged) Orange: Warning Red: Critical EM Console view Traps in Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 7/9

UPS Alarm list: Severity Warning Critical Alarm message UPS on Battery UPS utility power failed UPS communication failed UPS Battery entering Fault status UPS battery need to be replaced UPS battery reached low condition UPS battery is unavailable UPS has overload condition 4.3 Launching UPS properties from Unicenter For each UPS in all Unicenter views, you are able to access a certain amount of information depending on the type of equipment you have. For cards with an on-board web server, you are able to access the UPS properties Web Page. Select your UPS and "UPS Properties" item with one click. Running the UPS properties" from Unicenter. Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 8/9

4.4 EATON equipment and Unicenter compatibility list: EATON equipment designation Network Management card Minislot SNMP / Web 66102 Industrial Network Management card Minislot SNMP / Web 66103 Network Management Proxy / XML-@gent (Windows) Transverse card SNMP/Web 66074 Minislot card Card/ proxy Protocol Autodiscovery Receiving alarms (Traps) Card SNMP/HTTP OK OK OK Card SNMP/HTTP OK OK OK Proxy HTTP OK (**) Na NOK (*) Card SNMP/HTTP OK OK OK Card SNMP/HTTP OK OK OK SNMP/Web 66244 XML-Web card 66073 Card HTTP OK (**) Na OK SP WAN- UM Agent Proxy SNMP OK (**) OK na SNMP card 66245 Card SNMP OK OK na SNMP card 66062 Card SNMP OK OK na Accessing UPS properties using a browser (HTTP) (*): Unsupported option. With Network Management Proxy / XML-Agent, the address "http://<ip Address proxy>/eaton/default.htm" giving access to the UPS property page cannot be configured automatically with Unicenter. (**): Not recognised as EATON UPS equipment. Must be added manually. Select your equipment in the console and click on "Reclassify". Select the UPS class under UPS class. Modify the pollset_name properties of the snmp class: change host to UPS. (From the Unicenter 2D Map, select the UPS Icon and through right click select Viewer then Class Editor) na: not applicable. Computer Associates Unicenter Integration User s Guide 34 003 757 XU / AF Page 9/9