AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

Similar documents
AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT)

AT&T Switched Ethernet Service SM

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

AT&T Virtual Private Network Service (VPN) and AT&T VPN Express

Add an AT&T Switched Ethernet Service port to your site

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

Tarleton State University. Specifications

Construction Guidelines. for Providing Communications Services

AT&T Collaborate. IAD (s)

PoP ROOM: INSIDE AND OUTSIDE PLANT RULES & REGULATIONS

Installation Notes TII Model 341 Protector

Managed WAN SLA. Contents

ANSI/TIA/EIA-568-B Cabling Standard

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Managed WAN SLA. Contents

Basketball Shot Clock Set LX2180 Manual

FEMTOCELL MULTI-BAND SOHO B2/B4 (SS2FII)

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

PIX 520. PIX 520 Product Overview CHAPTER

Site Preparation CHAPTER

Business Customer Demarcation Information

Replacing an ESM/IOM CRU in the CSM200 Drive Module

Installing the Cisco MDS 9020 Fabric Switch

Cabling Infrastructure

Target Interface / Construction Compliance Inspection Checklist

CENTRAL TELEPHONE COMPANY NEVADA DIVISION ( SPRINT ) NEVADA LOCAL TERMS OF SERVICE

iconverter 2-Module Power Chassis

ANSI/TIA/EIA-568-B Cabling Standard NOTE

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Computer Network Design Guide Existing Systems 1 / 6

Power Supply (48Vdc, 2.5A)

PARTNER Contact Closure Adjunct

Intelligent Channel Bank Shelf

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Contractor Work Packet

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

CSM200 Expansion Tray

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

TIA/EIA 568A Sub-system HORIZONTAL CABLING

EMC Symmetrix VMAX Cloud Edition

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

AT&T INTERSTATE ACCESS GUIDEBOOK PART Special Access Services - East

Broadband Automatic Disconnect Switch. User Manual

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Brivo ACS Installation Guide August 2001

Equipment Installation Guide

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

KillTest. 半年免费更新服务

RS-232 Fiber Link Card System

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station

EP-ELVCTL Elevator Control (NION-16C48M)

INTERIM COMMUNICATIONS INFRASTRUCTURE PLANNING GUIDELINES

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

INSTALLATION INSTRUCTIONS FOR

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Delivered the Way Yo u Want

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

Installing the Cisco AS5400XM Universal Gateway

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

TABLET DOCK USER S GUIDE

NZQA unit standard version 2 Page 1 of 5

BDS-256 Battery Diagnostic System with BDS Controller. Installation Instructions

T3 Interface Converters

The six major components of a structured wiring system are:

4100/ VDC Converter Installation Instructions

Nortel Business Communications Manager Installation System. Release: 5.0 Document Revision: NN

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

4 Channel Contact Closure DIN Fiber Link System

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

ADTRAN ProServices Description of Service Offering. ProStart Remote Installation Services ActivReach Ethernet Switches

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

TABLET DOCK USER S GUIDE

Spring Test 9 due 05/11/2013

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

EOS-6000 Series Optical A/B Switch User Manual DC Version

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

MA-4006, MD-4006 and MU-4006 Mounting Assemblies

f) Telecommunications Equipment Rooms

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Transcription:

AT&T Dedicated Internet (ADI formerly known as MIS) and Private Network Transport (PNT) Site Preparation Guide 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies. The information contained herein is not an offer, commitment, representation or warranty by AT&T and is subject to change.

AT&T ADI & PNT on Ethernet site preparation guide AT&T will perform with your permission: Customer will perform the following: An AT&T engineer will explain to your site contact all customer responsibilities shown on this page The engineer will reach out to the site contact within 48 hours of your order to schedule a visit If you are eligible for the entrance facility offer*, AT&T will complete items 2-5 on this list. This will occur after you sign the systems permissions form If the entrance facility offer is not available in your area, you will be responsible for completing the work or hiring someone to complete the work For detailed information and responsibilities refer to the site preparation guide located on the Customer Resource Center *Your sales person will help you determine if you are eligible for the entrance facility offer Outside conduit specifications (Property Line to your building) Minimum 2 4 conduit with pull rope Minimum 3 sweeping radius Pull box required when: There are 3 or more right angles The path is longer than 300 *Dimensions for pull box 12 x 12 x 18 Wall mounted backboard 4 x 4 x 3/4 Fire retardant plywood Mounted to studs Electrical specifications AC power outlet on a dedicated fused breaker rated min. 15 amps OR Nominal voltage, 48VDC, +24/-24VDC, 110V Either power option needs to be located within 6 ft. of the AT&T equipment Relay racks / cabinets must be grounded Inside conduit specifications (Demarcation point to router) Needs to be completed prior to installation You may hire an electrical vendor to complete inside wiring A conduit or cable tray is required, and a clear path for access Minimum 2 conduit Additional inside wiring Inside wiring, unless otherwise noted, is your responsibility; you can do it yourself or hire a vendor Inside wiring includes: From the demarcation point to your ADI equipment (router) Note: Incomplete inside wiring is the number one reason for service delays Telephone land line (not mobile) Managed options require a land line If you do not have a land line, talk to your sales person about ordering one 2 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

all offers Site survey: Site contact responsibilities: Site contact responsibilities: If in a multi tenant building: AT&T will reach out to your local site Obtaining building access and being Overseeing the site build out and Working with the property manager contact to schedule a site survey, if familiar with the telecom rooms confirming the completion dates. or building owner to determine the applicable Please provide the local customer site Showing AT&T where the circuit demarcation (demarc) is located. The contact should be fully empowered to make decisions location of your company s demarc Acting as a liaison and advocate contact information: The demarc is inside the building Informing us of any parking, noise or when working with the building Name / Title Phone number / Email where the service terminates from the street Guiding AT&T during the site survey time restrictions; unloading zones, elevators, asbestos, hazardous materials, etc. owner or manager Confirming the demarc is in the same room as the router The site contact will work with AT&T to schedule building access, provide the installation address to the ordering team and problem solve, as needed visit, noting further action needed to complete the site requirements (take notes) Providing adequate working space, a clear path and easy access to the backboard, jack, land line, power outlets and the AT&T ADI router Providing inside wiring if the building s demarc is not in your location or on a different floor than the ADI router 3 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

Site preparation delays What to expect during site survey visit AT&T will negotiate a project schedule with all parties to enable service completion as close to your desired date as possible However, any changes to plans or any delays associated with site preparation can have a corresponding impact to the service delivery date Please try to complete the site preparation as soon as possible from the time you place your order. This includes any electrical requirements, the backboard for the network equipment and any applicable extended inside wire. This will help avoid an installation delay Please contact the AT&T ordering team and your account team representative if delays are anticipated so work forces can be rescheduled There are billing implications if the site is not ready in time The local site contact will meet with the AT&T engineers to walk through what he or she will need to complete before we can install the service. It s a good idea to take notes and keep the name and contact information of the engineer in case there is a question later We will keep the site contact notified if there are any delays on our end, such as special construction, or facility delays 4 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

General requirements Inside path The following pages contain information and a list of general requirements associated with fiber optic-based services. The AT&T access engineer or field technician will identify actual requirements for the specific installation during the site survey Share this information with your electrical contractor There are typically four (4) areas of customer obligation to facilitate timely equipment installation and delivery of service: Inside path Ground Power Floor space and environmental requirements For an additional fee, you can hire AT&T or an electrician to complete the inside wiring The inside path is the wiring that goes from the point where we bring the service to your building (demarc) to your ADI router The conduit must be a minimum 2 with a hard plastic corrugated interior duct, with pull rope If the building is shared by multiple tenants, the router and the demarc will likely not be in the same location. You will need to work with the building manager or building owner to coordinate the inside wiring Inside wire extensions take time, so you will want to schedule that as soon as possible. The AT&T engineer will be able to answer any questions 5 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

Grounding Grounding your router is your responsibility, we encourage you to consult with your electrical contactor AT&T provided equipment, customer relay racks, cabinets and router must be grounded by placing an exposed #6 or larger grounding wire to the building s ground source This ground wire will be attached to the closest ground rod (earth ground) or building bus bar available and run to the network terminating equipment location in the room All equipment requires a properly grounded 110v, 15 amp, 3-prong AC outlet Not properly grounding your equipment will result in service quality and maintenance issues A #6 stranded ground is required from your earth electrode system to the equipment room. This would be connected to a grounding bus bar, or otherwise directly connected to different components A #6 stranded ground is required from the grounding bus bar to the network terminating equipment Specific requirements may also be discussed with the AT&T access engineer or AT&T field technician at the time of the site survey visit 6 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

Power Network device Please provide a dedicated 110V circuit breaker rated at a minimum of 15 amps for the network device that connects your building to the AT&T network. The power cord must not be touching any other cables ADI router In addition, please provide a 110V outlet for the router and the modem. A modem is provided if you ordered an AT&T managed router Customer environmental responsibilities responsibilities A 4 x 4 x 3/4, fire retardant backboard, fastened to studs is required A (customer provided) regular telephone line should be installed prior to the router installation. This line will be connected to the modem and used by the AT&T installation engineer during the test and turn-up of your ADI service. It also allows for testing in the event of circuit interruption during the life of the service The ADI router should be installed less than 15 feet from the jack that connects to the router. The distance will ensure the cable inside the router box will reach the jack Operating environment should be between 40 (degrees) F and 85 (degrees) F to 85% relative humidity Because of the small size of most network termination equipment, a wall mounted installation is recommended (please see illustration on the next page) Another option would be a (customer provided) 19 rack of suitable strength and quality is also acceptable The choice for placement should be decided before the order is placed and is subject to confirmation following the site survey In a standard fiber installation, transport equipment is placed in a common area with access to the entire building. 7 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

Wall mount example 4 X 4 X 3/4 fire retardant plywood backboard mounted to studs Ethernet patch cable Fiber termination panel Orange Customer provided Blue- AT&T provided Optional fiber jumpers (caution: bend radius) Fiber drop Cable to ADI router (optical handoff) Fiber panel (optional) Network termination equipment 110V power cord 110V amp outlet, properly grounded, 3 prong 8 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

Network example modem Land line for out of band testing **LAN connection to customer equipment *WAN connection Circuit dmarc AT&T provided router Notes: This diagram is illustrative for AT&T Dedicated Internet (ADI) Customer will provide the land line *AT&T assigned WAN IP s **Usually these are AT&T assigned LAN IP s Local exchange carrier access AT&T point of presence Interoffice channel ADI point of presence & network 9 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.

10 2015 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies.