Green Data Centers A Guideline

Similar documents
MSYS 4480 AC Systems Winter 2015

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

MEASURE MONITOR UNDERSTAND

Power & Cooling Considerations for Virtualized Environments

18 th National Award for Excellence in Energy Management. July 27, 2017

Case study on Green Data Center. Reliance Jio Infocomm Limited

Green IT and Green DC

Green Computing: Datacentres

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Industry leading low energy evaporative fresh air cooling.

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

Power and Cooling for Ultra-High Density Racks and Blade Servers

Introducing the Heat Wheel to the Data Center

Thermal management. Thermal management

Planning a Green Datacenter

Session 6: Data Center Energy Management Strategies

Efficiency of Data Center cooling

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Rittal Cooling Solutions A. Tropp

1.0 Executive Summary. 2.0 Available Features & Benefits

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

The Multi-Faceted Role of Smart Sustainable Cities

Server room guide helps energy managers reduce server consumption

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

How to Increase Data Center Efficiency

Next Generation Cooling

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Scalable, Secure. Jason Rylands

Green Computing: Datacentres

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Switch to Perfection

Impact of Air Containment Systems

84 kw, Tier 3, Direct Expansion, 937 ft 2

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

A Green Approach. Thermal

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

Data Center Energy Savings By the numbers

Highly Efficient Power Protection for High Density Computing Applications

Google s Green Data Centers: Network POP Case Study

1.0 Executive Summary

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Application of Green Technology For Data Centre

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

HPE Energy Efficiency Certification Service

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Reducing Data Center Cooling Costs through Airflow Containment

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Inside the Data Center: Opportunities for Energy Efficiency

Recapture Capacity for Existing. and Airflow Optimization

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

Case Study Leicester City Council

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Data Center Trends: How the Customer Drives Industry Advances and Design Development

1008 kw, Tier 2, Chilled Water, ft 2

Virtualization and consolidation

Reducing Energy Consumption with

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

LCP Hybrid Efficient performance with heat pipe technology

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Modular data centres in containers

Retro-Commissioning Report

Energy Efficient Data Centers

Overcoming the Challenges of Server Virtualisation

White paper adaptive IT infrastructures

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

DC Energy, Efficiency Challenges

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

LG CNS Global Cloud Data Center

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Energy Efficiency and CHP Opportunities for Data Centers

Power Monitoring in the Data Centre

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Welcome Association of Energy Engineers to the Microsoft Technology Center

Taking The Heat Off University of East Anglia Data Centre

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Data Center Energy and Cost Saving Evaluation

FREEING HPC FROM THE DATACENTRE

Transcription:

Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging the Standardization Gap on Environmental Sustainability, Colombo Sri Lanka Oct 03-04 2013.

2 * Source: Dilbert United Features Syndicate

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 3

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 4

Sri Lanka s Information and Communication Technology Agency (ICTA) Information Infrastructure/Digital Divide connecting Sri Lanka s villages and towns to the world. E-Laws guiding necessary regulatory reform to enable e-commerce and e-government. ICT Skills developing necessary IT skills to support ICT industry development. E-Government under the re-engineering Government initiative, applying ICT to modernise the public sector and deliver e-services. ICT Industry promotion promoting Sri Lanka as an ICT destination Sri Lanka Government Cloud (2012) Provides infrastructure, platform and applications as a service to government, for hosting any government system, application, content or service, with-out the government organization having to spend on the infrastructure, themselves. 5

6

2007 2008 2009 2010 2011 2012 2013 2014 2015 IT Market 212 254 277 327 386 456 538 629 742 IT Market as % GDP 0.7 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 Hardware Sales 151 180 194 227 265 310 362 419 489 Services 37 45 50 61 74 89 107 128 155 Software 24 29 32 39 47 57 68 82 98 PCs (including notebooks) 120 144 157 184 216 254 300 347 405 Servers 14 16 17 20 24 28 33 38 44 Source : 2011 IT/ITES Report by ICRA All Figures in USD Million 7

Green Implementation % 8 Ahangama & Gunawardana (2012)

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 9

Public service e-government Servers Banking Portals Internet Storage Security Network Data Center Infra Gaming 10... Broadband / IPTV / Telecom Energy & Smart Grid Data center works as a Hub and information resources are being concentrated on the data center.

60% of total establishment cost of data center is caused by energy-relevant facilities. General Contractor Fee 8% Engineering 5% Contingency 9% Commissioning 2% Fit-Up Costs 9% Ventilation facilities, 20% Shell 7% Total cost of data center establishment Building maintenance 4% Power facilities, 36% Cooling Plant 72% Generator 45% Cost of ventilation-relevant facilities Raised Floor Cooling 28% Cost of power-relevant facilities UPS 27% Power Distribution 28% 11 * Source: IBM engineering estimates, 2008

HVAC system local distribution lines lights, office space, etc. to the building, 480 V UPS PDU computer racks computer equipment 12 backup generators

Total 275W Costs of Establishing a Data Center Load 100W VR 20W Room cooling system 70W UPS +PDU 20W Server fans 15W PSU 50W 13 source: Intel Corporation

Electricity Generation & Transmission Losses Power Conversion & Distribution Cooling Equipment ultimately reducing fuel burned at the power plant Reducing power demand and losses Server Load/ Computing Operations Delivered Electricity Lowering power conversion losses Will reduce cooling needs Reducing server power requirements 14 Fuel Burned at Power Plant

Survey result for data center experts Improved monitoring Power-handling efficiency Cooling is a limiting factor Power is also a constraining factor: Energy Cost Power availablity Regulatory CSER as core value Customers demanding Staff forcing issue 0 10 20 30 40 50 60 15 Source: Bathwick Energy Efficiency Benchmark Tool 15

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 16

Power Conversion On-site generation Server Load/ & Distribution CHP applications Computing Waste heat for Operations cooling Use of renewable energy Fuel cells Load management Server innovation High voltage distribution Use of DC power Highly efficient UPS systems Efficient redundancy strategies Alternative Power Generation Cooling Equipment Better air management Move to liquid cooling Optimized chilled-water plants Use of free cooling 17

18 Power Path Efficiency Power (kw) MW-h Cost ($k) Loads Load cooling 3.1 113 8.5 Systems (x100) (not including dc/dc & ac/dc) x 85% Dc/dc 2.1 109 x 70% 85% Power supply 5.1 2.1 62 9.8 x 90% 94% UPS 1.9 0.9 x 98% Distribution 0.4 0.3 x 76% Delivery Cooling 3.0 1.7 Total = 40% 51% Total 222 175 Original efficiency 40% Original Cost of power delivery = $8,200 / 100 Annual cost reduced by $3,500 / 100 8.2 4.7 16.7 13.2 Source: EPRI PEAC

Approach Savings Description Virtualize servers 10-40% Right-size NCPI 10-30% More efficient air conditioner architecture Economizer modes of air conditioners More efficient floor layout 5 12% More efficient power equipment 4 10% Coordinate air conditioners 0 10% Consolidation of applications onto fewer servers, typically blade servers Using a modular, scalable power and cooling architecture 7 15% Row-oriented cooling and shorter air paths 4 15% Choosing economizer options-offered air conditioners hot-aisle / cold-aisle arrangement with suitable air conditioner locations Best-in-class UPS, & light load efficiency rather than full load efficiency One air conditioner may actually heat while another cools; and One may dehumidify while another humidifies. 19 (1) APC White paper #114 Implementing Energy Efficient Data Centers, 2006 (2) NCPI : network critical 19 physical infrastructure

20 Air management Right-sizing Central plant optimization Efficient air handling Free cooling Humidity control UPSs and power supplies On-site generation Liquid cooling Design and M&O processes

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 21

SS 564 : Singapore Standards for Green Data Centers 22

PUE Power Usage Effectiveness DPPE - Datacenter Performance Per Energy WUE - Water Usage Effectiveness Annual water usage divided by IT equipment energy, and expressed in liters/kilowatt-hour; CUE - Carbon Usage Effectiveness To address carbon emissions associated with data centers DCMM - Data Center Maturity Model Clear goals & direction for improving energy efficiency & sustainability across all aspects of the data center. Parameters include power, cooling, compute, storage, and network. 23

Indicator Commonly agreed to by industry bodies and governments In practice, a data center consumes more energy that what its IT resources use. Additional energy is needed to feed the cooling systems, lighting and power delivery. If a data center has a PUE of 2.0 it means that for every 100 W of power needed by the IT Infrastructure, the data center needs 200 W from the utility grid. PUE = Cooling Load Factor (CLF) + Power Load Factor (PLF) + 1.0 24 1.0 represents the normalized IT load CLF is the total power consumed by chillers, cooling towers, computer rooms air conditioning, pumps, etc., divided by the IT load PLF is the total power dissipated by switch gear, UPSs, power distribution units, etc., divided by the IT load. PUE Indication of Efficiency 3.0 Very Inefficient 2.5 Inefficient 2.0 Average 1.5 Efficient 1.0 Very Efficient

25 DPPE is developed by the Green IT Promotion Council (GIPC) of Japan

26

Building Virtualization Power Storage integration Management Cooling Hot spot management 27 27

Action Summary Server virtualization Consolidating multiple servers to a single physical server reduces energy consumption by 10-40% Shut down unused servers Save 15-30% by simply shutting down comatose servers Server consolidation Bring lightly used servers tasks to a single server Storage consolidation Storage typically averages 30% utilization, yet companies typically hold the same information 20 times Invest in energy efficiency An Energy Star server draws around 30% less energy than a conventional one Hot aisle/cold aisle layout Physical arrangement of servers can reduce mixing of hot and cold air, improving efficiency Aisle enclosures Further reduction in mixing cold supply air with hot exhaust air Airflow improvements Decrease server inlet air temperatures and increase temperature of exhaust air to CRAC Seal off ducts Use grommets to reduce air leakage Adjust the temperature and humidity range Most data centers run cool and dry. They can save 4-5% in energy costs for every 1 F increase in server inlet temperature Air-side economizer Bring cooler evening and winter outside air into the data center Water-side economizer Cooling tower to evaporate heat and produce chilled water during winter 28

29 LEED like rating schema for Data Centers

Data Metrics & 1 Background 2 Energy Centers & 3 4 Best 5 Efficiency Energy Use Practices ITU Efforts 30

This Recomendation contains requirements for data center realization as selection of equipment, cooling, powering, and some suggestions to realize and conduct a data center with reduced impact. Recommendation ITU-T L.1300 states that reducing energy consumption and GHG emissions should be considered in the design and construction of data centres, and that constant monitoring will be required to consistently manage and improve energy consumption while the data centre is in operation. (Approved in January 2012) Best practices are outlined for the use, management and planning of data centres, for cooling and power equipment, for the optimum design of data centre buildings, and for the monitoring of data centres after construction. For example, applying best practice to cooling could reduce the energy consumption of a typical data centre by more than 50 per cent. 31

32

Recomendation that will contains definition of metrics for Data centers and Telecom Infrastructure 33 Recomendation that will establish measurement methods for the power/energy consumption of Data Centers and Telecom Infrastructure 33

Sekhar Kondepudi Ph.D. Smart Buildings & Smart Cities National University of Singapore Sekhar.Kondepudi@nus.edu.sg +65 9856 6472 34