GPLS-25 DATASHEET Março 2012

Similar documents
ULTRASONIC LEVEL METERS ULM 53L

Ultrasonic level meters ULM 53

Isolating repeater IRU 420

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Operating instructions. Switching amplifier DN0210 DN / / 2015

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

SM9000. Magnetic-inductive flow meter. Made in Germany

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

C5 Series Stainless Steel Photoelectric

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

Basic Series 18 mm Diameter Cylindrical Sensors

3RG7 Opto-BERO Photoelectric Proximity Switches

standard, short, preferential, top

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E4PA. Ultrasonic Displacement Sensor. Ordering Information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

FMF. Miniature Photoelectric Sensor. Flat Type. Model Number Legend SALIENT FEATURES. Sensing. Photoelectric

Operating instructions. Speed monitor D / / 2014

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

12 m 8 m 6 m 3 m 300 mm 500 mm 70 mm mm Power supply Vdc Vdc

Ultrasonic Level Sensors ULS 53 INSTRUCTION MANUAL. průmyslová elektronika

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features:

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

MLV41 Series Miniature Sensors

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

SENSORS. TLμ. Contrast Sensors - TLμ. All registration mark detection applications. Teach-in, Remote settings. Red/green or white LED emission

Thread length (overall length) material

Classification Enclosure rating Input voltage Type of

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

the Interactive Catalog

S40 SERIES INSTRUCTION MANUAL

Mini Photoelectric Sensor

Variable Area Flowmeter DATASHEET

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Operating instructions Memory plug E /02 11/2011

(see also technical drawings) Width with inlay

Safety Monitoring Relays

Inductive Proximity Sensor

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing

Slot Style Photoelectric Sensors

Biometric switch Harmony

E2Q4 Square Proximity Sensor

Operating instructions Electronic temperature sensor TN /00 04/2011

Installation Instructions Temperature transmitter TAA /00 06/2011

DFP Series Fiber Photoelectric Amplifiers

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating instructions Evaluation system for flow sensors VS / / 2013

ML17 Series Tru-Vue TM Sensors

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Datasheet - RSS 36-D-R-ST

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

OPT2011. High-performance distance sensor. Operating Instructions

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

External level devices for conductive point level switch

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

2 m cable, 4 wires Connection connector. M8 conn., 4-pole Approximate dimensions (mm)

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Operating instructions. Standstill monitor A / / 2011

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

TMT470L Temperature Transmitter

ML20 Series Long-Range Miniature Sensors

2. Actuator B: Ball type P: Pin type F: Flat type

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Level measurement. Applications. Special features. Description

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Active Distributors AS-i Safety, Active Distributors AS-i

Assembly. Function 41

Color Mark Photoelectric Sensor E3S-VS

E3Z. The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Operating Instruction

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Datasheet - MZM 100 B ST-1P2PW2REM-A

Optical distance sensors. Dimensioned drawing

Unaffected by Angle, Colour, or Dirt

LS 6600 Technical Datasheet

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Contents. Volume 8 Sensing Solutions CA E April

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

IB080QM65VA3 Part Number

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

AEW Pulse Adapter. Building Technologies

MODULES FOR SAFETY AND MONITORING

Transcription:

GPLS-25 DATASHEET Março 2012

THRU-WALL LEVEL SWITCHES GPLS 25 For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls Miniature performance in plastic housing Simple sensitivity setting by means of magnetic pen Variants with fixed cable or a connector Two-wire connection directly to the relay circuit or PLC input LED state indication Through wall level switches GPLS 25 are intended for liquid (conductive and non-conductive) level detection on glass or plastic gauge-pipes, tubes and tanks. The sensitivity and modes (SO normally open or SC normally closed) of the switches can be easily set by placing magnetic pen on sensitive spot. The connection is done by means of two wires directly into a circuit with relay or to binary input of control system. FEATURES OF VARIANTS GPLS 25N 0 GPLS 25N 1 Prismatic (refracted) electrode, shape-adapted to be attached to the gauging pipe or other tube. The fixing of the sensor onto a pipe is provided by plastic straps. Planar electrode, suitable for installation on fl at surfaces (e.g. plastic or glass tanks). The sensor can be fi xed with plastic straps or by double sided adhesive layer. DIMENSIONS DRAWINGS Variant "A" with cable outlet Variant "C" with connector LED Sensitive spot for setting Cable outlet or connector Electrode Magnetic pen MP 8 GPLS 25N 0 GPLS 25N 1 GPLS-dat-1.4

TECHNICAL SPECIFICATIONS Supply voltage Supply current Switched current (Min. / Max.) Remanent voltage ON state Switching frequency Conductive liquids Max. thickness of the vessel wall Non-conductive liquids with Ɛ r < 10* Ambient temperature range Temperature range at the tube or vessel surface / with double-side self adhesive tape Housing material Protection class Connection cable type (Variants A ) Weight (including 2 m cable) *) Ɛ r see Table of dielectric constants 6... 30 V DC Max. 0.6 / 7 ma (OFF / ON state) Max. 0.6 ma (OFF state) 100 ma 3.3 ma / 40 ma 1.8 V 6.0 V Max. 1 Hz 8 mm 3 mm -20... +80 C -20... +90 C / +60 C Plastic (PP) IP67 PVC 3 x 0.34 mm 2 PVC 2 x 0.34 mm 2 Approx. 60 g ELECTRICAL CONNECTION GPLS 25N _ S Positive pole (+ U) of power supply is connected through a load (relay) to brown wire or pin connector No. 1, negative pole is connected to white wire or pin connector No. 3. GPLS 25N _ P Positive pole (+ U) of power supply is connected to brown wire or pin connector No. 1, negative pole is connected to blue wire or pin connector No. 3. Load (relay) is connected to black wire or pin connector No. 2. Connection scheme of sensor with S type output Note: The sensor output is protected against short circuits. Capacity loads and loads with low sleep resistance (bulb) the sensor evaluates as a short circuit. In case of high ambient electromagnetic interference, parallel conductors with power lines, or lines at distances greater than 30 m, we recommend to use shielded cable. Connection scheme of sensor with PNP type output Legend: (1)... Terminals number for variants with connector BN Brown WH White BU Blue INSTALLATION AND RECOMMENDATIONS Plastic straps Point level detection on plastic or glass gauge pipes and tubes. The sensor is fi xed to the gauge pipe or tube by means of two plastic straps (2.5 mm width). The cable should be vertically downwards oriented. The maximum wall thickness of the tube depends on the detected medium (see technical data); the maximum is 8 mm. Applies to: GPLS 25N 0 Thru-wall level sensing of liquids in plastic or glass vessels with flat walls. The sensor is installed on a clean and degreased surface of the vessel wall. The attachment is done by doublesided adhesive layer. Orientation of the sensor can be arbitrary. Maximum thickness of the vessel wall depends on the detected medium (see technical data); the maximum is 8 mm. Applies to: GPLS 25N 1 GPLS-dat-2.4

SENSOR SETTINGS The setting is done by placing of magnetic pen MP 8 to sensitive spot M located on the front of the sensor. Short time attaching (up to 2 sec.) of the magnetic pen to the sensitive spot M makes the sensor open. Long attach (at least 4 sec.) of the pen when the level is changed, defi nes closed state of the sensor. In this way the sensitivity for the measured medium and switching modes S (normally open) or C (normally closed) is set. When changing the fl uid it is necessary to make the new setting. Sensitive spot mode O (normally open) mode C (normally close) When the level is low (the container is empty), attach the magnetic pen MP 8 to the sensitive spot M for short time (max. 2 sec.). When the level is high (the container is full), attach the magnetic pen MP 8 to the sensitive spot M for long time (min. 4 sec.). When the level is low (the container is empty), attach the magnetic pen MP 8 to the sensitive spot M for long time (min. 4 sec.). When the level is high (the container is full), attach the magnetic pen MP 8 to the sensitive spot M for short time (max. 2 sec.). FACTORY DEFAULT SETTINGS: Type GPLS 25 is set to detect to detect water and switching mode O (normally open state). STATUS SIGNALIZATION Indicator Orange LED Function Continuous light Sensor is closed (switched ON) Dark Sensor is open (switched OFF) Rapid flashing (period 0.2 sec.) * Unrecognized upper and lower limits or setting mistake Slow flashing (period 0.8 sec.) Short circuit at sensor output * Sensor with S type output, for each flash of the LED switches its output on for approx. 3 ms. This period is sufficiently short to avoid unwanted switching of relay contacts. For binary inputs, we recommend to set the filter so as not to respond to pulses shorter than 3 ms. ORDER CODE GPLS 25N cable Length of cable in meters (variant A ) Type of output: Electric connection: Electrode type: S 2-wire electronic switch P PNP (open collector) A Cable outlet (+ Spec. the length of the cable) C Connector 0 Prismatic (refracted) 1 Planar CORRECT SPECIFICATION EXAMPLES GPLS 25N 1 A P cable 5 m (1) planar electrode, (A) cable outlet with 5 m lenght fi xed cable; (P) output type PNP. GPLS 25N 0 C S (0) prismatic electrode, (C) electric connection with connector; (S) output type S (electronic switch). GPLS-dat-3.4

ACCESSORIES Standard included in the level sensors price 2 pcs of Plastic straps 2.5 x 200 mm 1 pc of Double-side self adhesive tape (GPLS 25N 1) 1 pc of Magnetic pen MP 8 Optional for extra charge Connector ELKA KV 3308 SAFETY, PROTECTIONS AND COMPATIBILITY The level sensor is equipped with a protection against electric shock on electrode, polarity, overvoltage and short-term current overload on the output. Electromagnetic compatibility is provided by conformity with standards EN 55022 / B, EN 61326-1, EN 61000-4-2,-3, -4 and -6. Version 05/2012 GPLS-dat-4.4 Dinel, s.r.o. U Tescomy 249 760 01 Zlín, Czech Republic Phone: Fax: +420 577 002 003 +420 577 002 007 sale@dinel.cz www.dinel.cz

Contactos/Contacts: Comercial/Commercial: Fernando Mena Costa e-mail: fcosta@bhb,pt Tel: (+351) 21 843 64 00 Fax: (+351) 21 843 64 09 Assistência/Service: Patricia Costa e-mail: ppcosta@bhb.pt Tel: (+351) 21 843 64 00