THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

Similar documents
THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

Modular Two-Wire Telecontrol System

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Manual Fiber Optic Interfaces

Accessories / 7XV5662

Modular telecontrol system for GPRS and network structures

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Residual overvoltage relay

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Operating instructions. Switching amplifier DN0210 DN / / 2015

Products no longer available

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

TVAC25100 TVAC25110 User manual

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Technical data. Safety notes. Product features

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Industrial Switches Industrial Switches

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

FL MC 2000E (SM40) LC

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

MC 11 EB-2 Power supply cabinet with external bus, AC version

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Accessories / 7XV5461

Converter Box Data Sheet

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

WI-I/O 9 Multi I/O Units

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Products no longer available

Operating instructions. Speed monitor D / / 2014

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Brief instruction. Version. 3en.

PTC-101-M12 Hardware Installation Guide

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Earth-fault Relay SPAJ 110 C. Product Guide

Manual Industry Interfaces

PSI-MODEM-SHDSL/SERIAL

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Feeder protection relay SPAA 121 C. Product Guide

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

BMF400 Input/output module

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

QUINT-PS/ 1AC/24DC/ 5

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

CMC III Universal Sensor

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Analog display for resistance current

SHEET. AI-FR Series Redundant Fibre Ring Hubs. AI-FR Series. Compatible with the baseband 2.5 Mbps ARCNET network

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

LVX Control Unit. Features:

Features and Benefits. Certifications

FEATURES DESCRIPTION FEATURES

MU110-6U. Analog output module 6 channel. User guide

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

USER MANUAL en-us ENGLISH

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

CAN 300 PRO, Communication Module

MINI MCR-SL-UI-2I(-SP)(-NC)

AO523 Analog Input Module

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

AUD-340 Installation Guide

TF501, TF521 Terminal Bases

EY-EM : Remote I/O module, ecolink

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

S800 I/O ABB Automation

Operating instructions. Standstill monitor A / / 2011

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

SK TU4-IOE-M12-C Part Number

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

Pen Drive USB Datalogger!

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Transcription:

Application-ready systems from the MFW product family 29.11.2006 Modular optical fibre telecontrol system Optimised transmission speed variant MFW-GOLWL-BA-UK-000 INFOwww.ees-online.de

Table of contents 1 Applicability 3 2 General notes 3 2.1 Symbols used 3 2.2 Terminology 3 2.3 Safety instructions 4 2.4 Correct and proper usage 4 3 Device description 5 4 Assembly and installation 6 5 Configuring the telecontrol system 7 5.1 General principles 7 5.2 Basic module 8 5.3 Expansion modules 8 5.4.1 Digital input 9 5.4.2 Digital output 9 5.4.3 Analog Input 9 5.4.4 Analog Output 9 6 Indicator lights 9 7 Diagnostic functions 10 7.1 Watchdog OK and Error codes 10 7.2 OK-relay 10 7.3 Diagnostic interface 11 8 Transmission ranges 13 9 Technical data 14 10 Accessories 15 MFW-GOLWL-BA-UK-000 Page 2 of 16

1 Applicability The description applies to the following MFW modules: Item number 97BLAGAN1BB1 97BLAGCN1BX1 97BLBGAN1BB1 97BLBGCN1BX1 97BLCGAN1BB1 97BLCGCN1BX1 2 General notes 2.1 Symbols used 2.2 Terminology Type MF-L1S00-G8DEX-DIA-1-BB-1 MF-L1S00-G8DAR-DIA-1-BX-1 MF-L1M10-G8DEX-DIA-1-BB-1 MF-L1M10-G8DAR-DIA-1-BX-1 MF-L1M20-G8DEX-DIA-1-BB-1 MF-L1M20-G8DAR-DIA-1-BX-1 The following symbols are used in this document: Safety instruction This symbol marks warnings, prohibitions and directions relating to hazards. It is essential that they are observed and obeyed. Additional note This symbol indicates additional information. Important section This symbol indicates particularly important information. Cross-reference This symbol refers to diagrams and to other locations within the document. MFW In general the MFW modular telecontrol network consists of one master and up to 31 substations. The speed optimised point-to-point connection version of the MFW Modular Telecontrol Network is only available by a system consisting of a central unit and a substation. Each station requires at least one basic module and a maximum of 4 expansion modules. MFW-GOLWL-BA-UK-000 Page 3 of 16

Basic module The basic module represents the minimum core of a telecontrol station. It contains at least the following function groups: internal modem (in this case a fibre-optic modem) 8 binary inputs or outputs with status LED, or an additional serial interface for protocol coupling two CAN bus interfaces for connecting the expansion modules watchdog LED and fault signalling contact Master module Using speed optmised optical fibre telecontrol system in every station a basic module designed as master module is required. A maximum of 4 expansion modules can be connected to it. Expansion module In order to increase the I/O scope up to 4 expansion modules can be connected to a basic module These are connected via the CAN bus interface. I/O module The basic modules contain 8 inputs or outputs. These are referred as I/O modules. In the same way, the expansion modules contain an I/O module consisting of 8 binary inputs, 8 binary outputs, 4 analog inputs or 4 analog outputs. Each I/O module is given a module number. The data is exchanged between modules with the same module number. The assignment of in- and output modules is done by the module number. 2.3 Safety instructions These operating instructions must be carefully read, understood and followed! Risk of interference with electronic devices! When operating the telecontrol system close to devices that are subject to interference, the special regulations for these areas must be observed! Risk of ignition from electromagnetic fields! The MFW modules must not be operated in the neighbourhood of inflammable gases or liquids (fuel depots, petrol stations, chemical works, gas containers etc.)! Risk of damage! The MFW modules must not be opened or subjected to improper modification! 2.4 Correct and proper usage The telecontrol system is intended exclusively for the applications described in these operating instructions. Any other usage can be hazardous and is forbidden. The manufacturer cannot be held liable for the consequences of improper use of the MFW modules or for any application that does not comply with the contents of these operating instructions. MFW-GOLWL-BA-UK-000 Page 4 of 16

3 Device description The modular telecontrol network (MFW) stands for a flexible, modular concept, which is able to use all available medias e.g. telephon cables, three-phase current wires, cableshields, potential free wires, optical fibre and different radio frequencies for data transmission. In some applications (e.g. Intertripping of railway substations ) the whole performance complexity is not necessary instead an optimised variant for the special request is needed. For such requirements the MFW-system was optimised for high transmission speeds between a point-topoint connection over optical fibre. The delay between applying a signal on the one side up to the appearance of the message on the other side is below 100 ms. The parameterisation of the system is done by DIP-switches for easy handling. In every station the telecontrol system consists of a basic module (designed as master station). This includes the following function groups, display and setting elements: Internal fibre optic modem RS232 diagnostics interface I/O Unit with 8 binary outputs with status LED Two CAN bus interfaces for connecting the expansion modules Watchdog LED and fault signalling contact DIP switch for setting of module number etc. Each basic module can be fitted with up to a maximum of 4 expansion modules in order to increase the I/O scope. These are connected via the CAN bus interface. The assignment of input and output modules is done by module numbers, which are set by DIP-switches. In the event of a fault, the system detects the faulty communication and reports it via LED and relay contact in both stations. If the serial diagnostic interface is used, this information can also be evaluated via this interface (e.g. error codes, transmission quality etc.). The use of optical fibres as transmission media ensures a robust fault-free transmission over long distances. For each direction of transmission an individual optical fibre is used. There are three types available for the connection of the different fibre optic types: 1. Multimode fibre 50/125 µm or 62.5/125 µm core/cladding diameter. Wavelength 1300 nm 2. Monomode fibre 9/125 µm core/cladding diameter, Wavelength 1310 nm 3. Multimode fibre 50/125 µm or 62.5/125 µm core/cladding diameter. Wave length 820 nm The distance which can be bridged depends on the glass fibre type used, on the plugs and on the splice losses and can amount up to 22 km. For the fibre optic connection to the basic module the ST type plug connection is used. MFW-GOLWL-BA-UK-000 Page 5 of 16

4 Assembly and installation 1. Unpack all the telecontrol system s modules, and check them for transport damage. Report any transport damage immediately to the responsible carrier. Please check that the delivery is complete. The delivery can include master modules, expansion modules and other accessories. 2. Select mounting locations for the individual stations. 3. Module configuration ( see section Configuring the telecontrol system ) The following DIP switch settings must be done when starting the system for the first time: Module function s for all modules with I/O Current or voltage input at analog input modules Counting or pulse I/O at digital modules 4. Engage the basic module and any expansion modules [7] that may be required on the mounting rail [6]. 5. Connect the input and output leads. The length of the input and output leads should not exceed a maximum of 3 m. 6. Connect the transmitting and receiving optical fibres to the appropriate sockets [15]. MFW-GOLWL-BA-UK-000 Page 6 of 16

7. When required connect optional input/output modules using the supplied cable to the expansion sockets [17] (COM1, COM2). Assembly and installation are carried out in accordance with the associated instructions. 8. Connect the power supply to the basic module.. The length of the power supply lead should not exceed a maximum of 10 m. 9. Switch on the power supply. Watchdog LED [1] lights up. The substation is ready for operation. LED flashes see section: Watchdog LED and error codes 5. Configuring the telecontrol system 5.1 General principles Data within the telecontrol system is exchanged on the basis of module numbers. The assignment of input and output modules is done according to the following table. Input modules Output modules Module type Module type 0 8 DI incl. 4 CV 128 8 DO incl. 4 CV 1 8 DI incl. 4 CV 129 8 DO incl. 4 CV 2 4 AI 130 4 AO 3 8 DI 131 8 DO Table: Assignment of module numbers Using digital input module with module number 3 counting values can not be transmitted. Note: Refering output modules have always in this version numbers + 128! All the important settings can be made with the aid of DIP switches. These include, for instance, the module function, module number, selection between static and counter values in the case of digital I/O or between current and voltage in the case of analog signals and so forth. DIP switches A and B [4, 5] are located on the bottom side of the basic modules. MFW-GOLWL-BA-UK-000 Page 7 of 16

5.2 Basic module The following settings can be done by DIP-switches: Meaning Values DIP switches Module function - bidirectional operation B1 B2 - unidirectional (transmitter) - unidirectional (receiver) - test mode of the I/O module see table Assignment of A1 A8 module numbers Number of pulse counters 0 4 B6 B7 Programming switch for the master module: 5.3 Expansion modules Each basic module can be fitted with up to a maximum of 4 expansion modules in order to increase the I/O scope. The following modules are available for this purpose: EM-G8DEX-0-BB-0 EM-G8DAR-0-BX-0 EM-G8DAL-0-BB-0 EM-G4AE0-0-BX-0 EM-G4AA0-0-BX-0 No function No function Pulse counter Pulse counter No function No function No function Module function Module function No function 8 digital inputs 8 relay outputs 8 transistor outputs 4 analog inputs (0..10 V or 0..20 ma) 4 analog outputs (0..10 V or 0..20 ma) A precise description of the way the modules operate can be found in the operating instructions for the MFW expansion modules. Only the necessary DIP switch settings will be listed below. The assignment of the DIP switches may be read from the label on the side of the module or found in the expansion module s operating instructions. MFW-GOLWL-BA-UK-000 Page 8 of 16 Addressing: (examples for module numbers) Module 0 Module 4 Module 10 Module 255 Function in the system: Bidirectional Transmitter Receiver Number of pulse counters:

5.4.1 Digital input Meaning Values of the I/O module 0 250 Type of I/Os 1-4 static or pulse Maximum count rate 1 Hz / 10 Hz 5.4.2 Digital output Meaning Values of the I/O module 0 254 Type of I/Os 1-4 static or pulse Maximum count rate 1 Hz / 12 Hz 5.4.3 Analog input Meaning Values of the I/O module 0 250 Current or voltage input may be set for each Current / voltage channel 5.4.4 Analog output Meaning Values of the I/O module 0 250 6 Indicator lights MFW-GOLWL-BA-UK-000 Page 9 of 16 9 Watchdog light OK 10 Indicator lights Digital inputs or outputs light up if a signal is present. 11 The External module indicator light lights up if an external module is connected. 12 No function 13 TX transmitting data over optical fibre 14 RX receiving data over optical fibre

7 Diagnostic functions A variety of diagnostic information is available to monitor and assess the data link. These include, for instance, station errors indicated via the LED matrix display or by a relay contact, or more detailed information via the diagnostic interface. 7.1 Watchdog-LED OK and error codes The OK Watchdog light [9] provides information about the current error status: Permanent light = no error Flashing = error Off = no power supply The sequence of flashes is composed of: No. of long flashes 1st error code digit No. of short flashes 2nd error code digit Pause For example: ---- (= error code 24) When more than one error occurs at the same time, the one with the highest priority is always the one that is indicated. No Error Comment 12 CAN bus error The link between the basic module and the expansion module is faulty. 13 Error in partner station The partner station is reporting an error. 16 Bad connection to partner station (poor reception, or none at all, at the partner station) 17 Bad connection from the partner (poor reception, or none at all, at this station) station 61 Serial interface error The error only occurs on basic modules with a serial interface. It occurs if this communication is faulty. After loading parameters, they are stored in the internal EEPROM. By this time the LED flashes in a very fast sequence. This procedure has not to be interrupted by switching off power supply, otherwise there will occur data losses. 7.2 OK -Relay In addition to the Watchdog-LED OK a relay with a change-over contact monitors the condition of the station. Contact 14 / 15 closed = error or supply failure Contact 15 / 16 closed = no error MFW-GOLWL-BA-UK-000 Page 10 of 16

7.3 Diagnostic interface The basic modules have an RS 232 interface that can be used as a diagnostic interface. The diagnostic interface can be used to obtain additional information about the condition of the system with the aid of a terminal. The terminal must be set as follows for this purpose: - 9600 baud - 8 bits - 1 start bit - 1 stop bit - no parity - no hardware or software handshake The following sections list the commands that can be used to ask for information. Upper and lower-case are ignored in the letters composing the command. The commands have to be completed with <ENTER>. Command/ syntax VQ<x> Function Quality of connection The ratio of responses to inquiry telegrams for this substation is returned, expressed as the figure per thousand (0...999). No x or x=1 - Switch on output of the connection quality (continuous output) All other values of x - Switch off output The connection quality output has the following format: E = <V1>%, G = <V2>%<cr> V1 - connection quality (reception at this station) V2 - connection quality (reception at the partner station) For example: E = 100 %, G = 100 % F<No.> F without <No.> - Output of the current error (error codes) F<No.> - Output of the error text belonging to the error number <No.> N U1 T... Z<n> For example: F<ENTER> Error: 12,13, F12<ENTER> Error: CAN bus error F13<ENTER> Error: Error in partner station Output of the serial number Query of the current substation error The function returns the error code of the substation s current error. Only the most significant error is always reported. Reading parameters <52> Serial number of the module <53> Version number of the software Specifies the pulse width of the output pulse for all outputs that are set to generate pulse outputs. n =1...256 pulse width = n x 40 ms Standard setting n =1 MFW-GOLWL-BA-UK-000 Page 11 of 16

8. Transmission ranges The range of the optical fibre system is determined by the transmission power, the receiver sensivity and the losses on the transmission path. The difference between transmission power and receiver sensivity is called budget. The budget correspond to the maximum allowed losses on the transmission path with which a data tranmission is still possible without having any reserve. The possible range is calculated as follows: Range (as km) = ( Budget (db) - Reserve (db) ) / Optical absorption (db per km) For the design of a transmission path the entire budget can not be taken into account, due to the fact that reserves for e.g. additional repairs which cause splice losses should be considered. The following table shows recommended values for the distances on basis of typical results. The actual distance has to be determined according to the transmission perfomance rating of the used components ( Optical fibre, plugs, numbers of splices,... )! Optical fibre type Core/cladding diameter Monomode 9/125μm Multimode 50/125μm Multimode 62.5/125μm Multimode 50/125μm Multimode 62.5/125μm Wavelength Budget min. / typ. MFW-GOLWL-BA-UK-000 Page 12 of 16 Typical optical fibre attenuation Connector/ splice reserve Transmission range min. / typ. 1310nm 12db / 18db 0,4db / km 6db 15km / 30km 1300nm 11db / 15db 0,5db / km 4db 14km / 22km 1300nm 15db / 18db 0,9db / km 4db 12km / 15km 820nm 11db / 15db 2,4db / km 4db 3km / 5km 820nm 16db / 20db 3,0db / km 4db 3km / 5km

9 Technical data Rated operating voltage 24 V DC Operating voltage range 20... 32 V DC Air humidity maximum 95 %, non-condensing Operating and ambient temperature -20 C... +60 C Connection terminals Nominal cross section 2.5 mm 2 Housing / protection class Plastic / IP 40 Version for monomode optic fibre @1310 nm Budget minimal/typical with 9/125 µm fibre optic 12 db/18 db Optical fibre connection plugs 2 ST sockets Version for monomode optic fibre @1300 nm Budget minimal/typical with 50/125 µm fibre optic 11 db/15 db Budget minimal/typical with 62,5/125 µm fibre optic 15 db/18 db Optical fibre connection plugs 2 ST sockets Version for monomode optic fibre @820 nm Budget minimal/typical with 50/125 µm fibre optic 11 db/15 db Budget minimal/typical with 62.5/125 µm fibre optic 16 db/20 db Optical fibre connection plugs 2 ST sockets Digital input module Power consumption Signal voltage Input resistance max. count rate min. pulse width / pause Electrical isolation between signal and supply voltage Digital output module Power consumption With relay outputs With transistor outputs Contact loading of the relay outputs* minimum maximum Total 230V AC current (purely ohmic load) Load capacity with transistor outputs min. pulse width / pause Electrical isolation between output and supply voltage MFW-GOLWL-BA-UK-000 Page 13 of 16 approx. 2.5 W see table see table 10 Hz 50 ms 4 kv eff approx. 3.5 W max. 2.5 W logic + load current 1,2 V /1 ma 250 V AC / 400 ma 250 V AC / 2 A (pure ohmic load) 30 V DC /2 A 110 V DC /0,2 A 220 V DC /0,1 A maximum 8 A maximum 50 ma per output 40 ms** 4 kv eff (not at transistor outputs!) * We would be happy to supply you with more precise specifications on request. ** Other figures on request Type description Nominal voltage Voltage range limit Input resistance UF-L1S00-G8DEX-DIA-1-BB-1 24 V AC/DC 16 V - 48 V AC/DC 10 kω UF-L1S00-G8DEX-DIA-1-BE-1 60 V AC/DC 35 V - 75 V AC/DC 22 kω UF-L1S00-G8DEX-DIA-1-BF-1 110 V AC/DC 75 V - 130 V AC/DC 68 kω UF-L1S00-G8DEX-DIA-1-BJ-1 220 V AC/DC 180 V - 255 V AC/DC 180 kω Digital input modules are deliverable in different signalling voltages. The corresponding voltage is defined by the 23th character of the type description.

Basic MFW module Terminal assignments Basic module with 8 digital inputs MFW-GOLWL-BA-UK-000 Page 14 of 16 Dimensions in mm Basic module with additional serial interface

Modular optical fibre telecontrol system Basic module with 8 output relays 10 Accessories Only accessories approved by the manufacturer (input/output modules etc.) may be connected to the MFW module. Additional modules for digital and analog input and output are available for the basic MFW modules. Further accessories and more detailed information may be found in the appropriate product sections in the catalogue. HOTLINE +49(0)7191-182 235/214 Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 D-71522 Backnang/Germany P.O.Box 12 40 D-71502 Backnang Phone: +49(0)7191/182-0 Fax: +49(0)7191/182-200 e-mail: info@ees-online.de The right to make technical changes is reserved INTERNET www.ees-online.de