Dual Fiber SWIR Laser Doppler Vibrometer

Similar documents
VibroFlex. VibroFlex Non-contact vibration measurement from nano to macro Product brochure

VibroFlex Compact Compactness meets versatility Preliminary datasheet. VibroFlex Compact

Vibrometer Introduction

More Precision. thermoimager TIM // Compact thermal imaging cameras

OFV-2500 Vibrometer Controllers

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

below. AOTF Module / Optics R O B U ST. R E L I A B L E. A C C U R A T E AOTF Video Adapter (Series VA310) KEY FEATURES POTENTIAL APPLICATIONS

CLV-2534 Compact Laser Vibrometer

POWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS

Laserline LDM The compact class for diode laser

Polytec Industrial. Vibrometer. Advancing Measurements by Light

RoHS COMPLIANT 2002/95/EC

Goldeye G-033 TEC1. Description. Goldeye G High-speed VGA InGaAs camera. Benefits and features. Options

PIXIS: 512 IMAGING GROUP

APPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment

Goldeye G-032 TEC1. Description. Goldeye G VGA InGaAs camera with large pixel. Benefits and features. Options

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

Product Specifications

More Precision. optoncdt // Laser displacement sensors (triangulation)

LSM-500H/501H/503H/506H/512H Laser Scan Micrometer SERIES 544 Non-contact Measuring Units

RoHS COMPLIANT 2002/95/EC

Mitutoyo General Catalog

More Precision. optoncdt // Laser displacement sensors (triangulation)

Easy integration into complex experimental setup

More Precision. optoncdt // Laser displacement sensors (triangulation)

Goldeye CL-032. Description. Goldeye CL all purpose SWIR camera

Technical Specifications for High speed PIV and High speed PIV-PLIF system

User Manual DUO BEAM/RG

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

IMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

More Precision. optoncdt // Laser displacement sensors (triangulation)

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Leica TCS SPE. Spectacular Imaging! Technical Documentation

More Precision. optoncdt // Laser displacement sensors (triangulation)

Goldeye CL-008. Description. Goldeye CL High-speed, low-cost InGaAS camera

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014

Portable vibration calibrator Model 28959G

More precision. thermometer CTVideo/CSVideo // Infrared temperature sensors

Quad-RO: 4320 X-RAY GROUP

StingRay and BioRay FEATURES

SLC ultra low jitter Clock Synthesizer 2 MHz to 7 GHz

A Global Laser Brand. Versatile Module

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Goldeye G-032. Description. Goldeye G all purpose short-wave infrared camera

IMAGING GROUP x 1300 imaging array; 20mm x 20mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

SpectraTec X. Multi- λ Laser Light Source BLUE SKY RESEARCH WAVELENGTHS

Dynamic & High-Resolution

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optocontrol // Optical precision micrometers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

IMAGING GROUP x 2048 imaging array; 13.5mm x 13.5mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

Thread Mountable Cameo Laser Diode Module

SYNCERITY TM 1024 x 256

More Precision. optocontrol // Optical precision micrometers

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

The World s Smallest Displacement Sensor!!

Goldeye G-032 SWIR Cool - low-noise short-wave infrared camera

More Precision. optoncdt // Laser displacement sensors (triangulation)

Precise Fiber Couple Laser Light Source

More Precision. optocontrol // Optical precision micrometers

Applications: Astronomy, Photometry, EL/PL Imaging, Luminescence & Fluorescence Imaging, and Bose-Einstein Condensate (BEC) Page 1 of 7 IMAGING GROUP

SYSTEMS PROPOSED FOR MEASURING, MONITORING AND ANALYSIS VIBRATION OF MACHINES FROM TEXTILE INDUSTRY

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

OFV-5000 Modular Vibrometer. OFV-5000 Modular Vibrometer Non-Contact Vibration Measurement Product Brochure

PI-MAX 4: 1024i-RF. Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

The Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices

405 nm Diode Lasers. 14-pin BF, D-type OEM Module & Turn-key Systems. 405 nm Single-Mode Wavelength Stabilized Diode Lasers

SR4000 Data Sheet.

Compact design with integrated controller

Product STC-E42A STC-E43A. Chip Size 7.40 (H) x 5.95 (V) mm 5.59 (H) x 4.68 (V) mm Cell Size 8.4 (H) x 9.8 (V) µm 6.35 (H) x 7.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

The Original Green LED Incorporated Digital Micrometer

UF-1000CL High Speed CCD Camera User's Manual

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

UP-800CL Digital CCD Camera User's Manual

DigiPot Software Configuration Menu

PyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.

More Precision. thermoimager TIM // Compact thermal imaging cameras

Prisma II Platform. Optoelectronics

More Precision. scancontrol BL // 2D/3D blue laser scanner

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

RgBLase LLC P/N: FB 671 XXX Diode Pumped Solid State Laser Module

MODEL LLT-1000 LIDAR LEVEL TRANSMITTER

More Precision. optoncdt // Laser displacement sensors (triangulation)

Color CCD Camera User's Manual

Specifications FOX Matrix 3200/7200/14400/320x Series, SMX 88/1616 FOX

SCALA. Scanning Laser Analyzer

NTSC/PAL. 3CCD Color Video Camera BRC-300 BRC-300P

IDS3010 Ultra Precision Sensor

Laser Triangulation Displacement Sensors

More Precision. thermoimager TIM // Compact thermal imaging cameras

TECHNICAL DATA OPTIV PERFORMANCE 443 DUAL Z

NEW. Very high-speed profile measurement for industrial in line applications. 2D/3D profile sensor SENSORS & SYSTEMS

More Precision. optoncdt // Laser displacement sensors (triangulation)

Specifications Summary. Active pixels 1024 x Pixel size (W x H) 13 µm x 13 µm. Active area pixel well depth (typical) 100,000 e -

More Precision. optoncdt // Laser displacement sensors (triangulation)

Complete Barrel Measuring and Inspection System. PS Series. User s manual

Helium-Neon Laser Heads 1100 Series

Transcription:

Dual Fiber SWIR Laser Doppler Vibrometer The OptoMET Dual Fiber SWIR Vibrometer consists of a SWIR vibrometer and a flexible Dual-Fiber head, different objective lenses either collimated or focused are available. With its build-in stabilized SWIR laser the vibrometer gets a very good signal-to-noise ratio on all technical and organic surfaces. Thanks to our innovative digital signal processing technology the vibrometer achieves highest accuracy in combination with an outstanding resolution up to fm for displacement. With an additional fiber switch multiple fiber heads can be connected to the vibrometer, so you can multiplex many different channels (2, 4, 8, 16,...), the fiber switch comes with an electrical interface (Ethernet, USB, TTL,...) and can be remotely operated by a PC. Features: Excellent signal level thanks to its build-in stabilized SWIR Laser Small and flexible fiber heads Ability to multiplex many fiber heads using a fiber switch Passive and robust fiber head design (no active electronic) Max. velocity: 24.5 m/s Auto- and manual Focused fiber heads working distance up to 100 m Collimated fiber heads available Ideal for: Difficult measurement conditions: dark / rough surfaces Where physical access is difficult Quality inspection from different points of view Measurements in vacuum- or climatic chambers High speed vibration measurements Applications which require small spot sizes or long working distances Large amplitudes at small working distances 1

Set up Dual Fiber Vibrometer Fiber Head Vibrometer Output Miniature Compact Manual-focus Auto-focus Dual Fiber Vibrometer BNC Analog Output Ethernet Digital Output Miniature Fiber Head with camera: Fix Working Distance: OBJ-DF-F Dimension (D x L): 11 x 52 mm Fix working distances: 4, 9, and 16 mm Inspection camera: resolution 640 x 480 pixel Compact Fiber Head: Collimated lens: OBJ-DF-C Fix Working Distance: OBJ-DF-F Dimension: 89 L x 43.9 B x 95 H mm Weight: 0.5 kg Manual fokus Fiber Head: Short-Range: OBJ-DF-SR Mid-Range: OBJ-DF-MR Manual focused lens with variable working distance Dimension: 157 L x 43.9 B x 95 H mm Weight: 1.2 kg Autofocus Fiber Head: Mid-Range: OBJ-DF-AF-MR Auto-focused lens with variable working distance: Dimension: 175.5 L x 43.9 B x 95 H mm Weight: 0.8 kg LR-Range: OBJ-DF-AF-LR Auto-focused lens with variable working distance: Dimension: 221 L x 43.9 B x 95 H mm Weight: 0.9 kg SWIR Vibrometer Dimension: 370 L x 120 B x 100 H mm Weight: 8 kg SWIR laser, eye safe, laser class 1 Bandwidth: 0 Hz - 10 MHz Max. velocity: 24.5 m/s 2

Multiplex many fiber heads using a fiber switch Vibrometer Ethernet Ethernet Windows / Linux PC with OptoGUI software Fiber switch Multiplex 2, 4, 8, 16 or more fiber head Fiber switch technical data: Switching times 2 ms Guaranteed lifetime > 100 Mio cycles Switching frequency < 50 Hz Number of channels 2, 4, 8 or 16; other channel counts on request Electrical interface Ethernet, USB, RS232, TTL, I2C Operating temperature 0 60 C Operating voltage integrated power supply 110-250V Remote control: Autofocusing of fiber heads Auto- or manual switching via Ethernet / OptoGUI software via Ethernet / OptoGUI software Measurement data: Type Export format Time domain, Frequency domain, Transfer function UFF-, csv 3

Vibrometer general data Measured quantity Signal processing Maximum velocity Number of measurement ranges Vibration resolution Frequency bandwidth Source impedance Laser wavelength Laser safety class User interface output User interface input Operating temperature range Dimensions Weight Power supply Decoder selection Analog output Ethernet digital output Velocity, displacement, acceleration Digital (OptoMET UltraDSP Technology) 24.5 m/s Up to 14 for velocity / 19 for displacement Down to 1.7 nm/s / 50 fm 0 Hz - 10 MHz 50 Ohm Measurement laser: 1550 nm, Targeting laser: 510-530 nm Measurement laser: output power <10 mw, eye-safe, class 1 Targeting laser: output power <1 mw, eye-safe, class 2 Color screen 3.5" + 20 segment LED bargraph Touch screen, knobs with push-button, key switch (power) +5... +40 C Length x width x height (excluding handle): 380 x 180 x 148 mm 8 kg + fiber head 110-240 V AC (50-60Hz) or 12 V DC D-VD-1N / D-VD-2N / D-VD-2N-R / D-VD-3N / D-VD-4N/ D-VD-5N D-DD-1N / D-DD-2N/ D-DD-2N-R / D-DD-3N / D-DD-4N / D-DD-5N D-AD-1N / D-AD-2N/ D-AD-2N-R / D-AD-3N / D-AD-4N / D-AD-5N - Up to 3 BNC analog outputs - Data rate: 160 MSamples/s @ 16-bit - Output voltage range: ± 2 V - Data rate: 1 GBit (53.3 MSamples/s @ 16-bit) - With a data acquisition and analysis software - Remote control feature Dimension of the Vibrometer: 148 379,4 90 3 x 3/8-16 UNC 20 40 4

Indicators / operating: 1 2 3 4 5 6 7 8 9 10 11 12 Touch screen LCD 3.5-Inch Signal Level Displacement measuring ranges Velocity measuring ranges Acceleration measuring ranges Ethernet Output acceleration Output velocity Output displacement Power Lock Laser 12 1 11 10 9 8 7 2 3 4 5 6 Fiber Head general data Dimension of the autofocus Fiber Head without objective lens: 95 141,5 Mounting plate for tripod 43,9 3/8-16 UNC 1/4-20 UNC 12,5 12,5 M8 Autofocus lenses technical data Specification Focal length (mm) Min. stand-off distance (mm) Spot size in µm at: 150 mm 500 mm OBJ-DF-AF-MR OBJ-DF-AF-LR Mid-Range Long-Range autofocus autofocus 150 mm... 10 m 500 mm... 100 m 50 100 150 500 60 130 5

Dimension of the manuel Fiber Head without objective lens : Mounting plate for optional SWIR camera 95 69,5 Mounting plate for tripod 3/8-16 UNC 43,9 1/4-20 UNC 12,5 12,5 M8 Manual- and Fix lenses technical data OBJ-DF-SR OBJ-DF-MR OBJ-DF-C OBJ-DF-F Short Range Mid Range Specification collimated fixed working distance manuel focus manuel focus 45 mm... 5 m 150 mm... 10 m Focal length (mm) - 40 / 50 / 75 / 100 / 150 / 200 25 50 Min. stand-off distance (mm) 0 27 / 37 / 64 / 89 / 139/ 189 45 150 Spot size in µm at: 1400 27 mm 17 37 mm 22 45 mm 50 64 mm 33 89 mm 44 139 mm 66 150 mm 60 189 mm 88 Laser product label DO NOT STARE INTO BEAM Class 2 Laser Product Laser CLASS 1: invisible, 1550 nm, output power: <10 mw Laser CLASS 2: visible, green laser beam, 510-530 nm, output power: <1 mw 6