NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

Similar documents
NGC-40-BRIDGE CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM NGC-40 SYSTEM INSTALLATION INSTRUCTIONS

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

TT-NRM. Network Relay Module Installation Instructions WARNING:

FLEX Ex Spring Clamp Terminal Base

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

MGate MB3170/MB3270 Quick Installation Guide

RS485 MODBUS Module 6RO

INJ-24A Series Quick Installation Guide

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

General Operating, Maintenance and Installation Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

MGate 5105-MB-EIP Quick Installation Guide

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ASTAT XB/XBm Remote Operator

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PLC PFC200 Controller PFC200 CS 2ETH RS

MGate 5111 Quick Installation Guide

Carbon Monoxide Sensor - ModBus

Serial Data DIN Fiber Link System

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Installation Instructions

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

ETHERNET/MFC 010 Technical Datasheet

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

DeltaV Bulk Power Supplies

S-series Horizontal Carriers

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

PTC-101-M12 Hardware Installation Guide

3500/32M 4-Channel Relay Module

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

RS485 MODBUS Module 8I8O

DTM Distributed Transmitter Monitor

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

ACS-30-EU-MONI-RMM2-E

S-series Horizontal Carriers

Description. System Event List Alarm Event List All module and channel data Current alarm data (quick view) Nine custom display options.

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

MOXA EtherDevice Switch & PoE Splitter

01C06/05. Programmable Controller. TomaHawk 8635A. Key benefits. Typical applications for system control

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

PSI-MODEM-SHDSL/SERIAL

Installation & Operation Manual

NetBiter I/O Extender User Manual

HomeWorks QS Processor

DeltaV Bulk Power Supplies

Installation Instructions

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

iologik 2500 Series Quick Installation Guide

Product Features. Wireless Compliance: IEEE a Compliant IEEE b Compliant IEEE g Compliant IEEE n draft Compliant

iologik E1200H Series

RS 485 Mini Modbus 1AO

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

ICF-1150 Series Quick Installation Guide

Hardened PoE Ethernet Switch

RS485 MODBUS Module 8AO

exp-s1110pe PoE+ Gigabit Ethernet Extenders

ISOMETER isoev425 with coupling device AGH420

EDS-P510 Series Quick Installation Guide

COGNEX. Checker SensorView. Quick Reference Guide

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

IMC-101 Series Quick Installation Guide

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

PD765 TRIDENT. Trident Series Process & Temperature Meters.

HomeWorks QS Processor

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

8-Port 10/100BASE-TX Hardened Ethernet Extender Switch

ICF-1150 Series Quick Installation Guide

Signamax Connectivity Systems

RS485 MODBUS Module 16I-M

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Serial/Ethernet Converter

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

Trendmaster* Galvanic Isolator

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

PD765 TRIDENT. Trident Series Process & Temperature Meters.

EDS-G205A-4PoE Hardware Installation Guide

H704-42(H)(E), H704-42/1(H)(E)

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

RS485 MODBUS Module 8I8RO

Product Description Page. Remote user interface and communications device 409

MODEL: GR8-EM. Communication Adaptor GR8 Series

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

PTC-101 Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Stride Industrial Ethernet Switches

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Momentum 171 CCC Processor with Ethernet Communication Port

Transcription:

NGC-40-BRIDGE Control and Moniting s f use with the nvent Raychem NGC-40 System Installation Instructions B C D A DESCRIPTION The nvent RAYCHEM NGC-40-BRIDGE module provides the interface between a panel's internal CAN-based netwk and upstream devices. Multiple communications pts are suppted, allowing serial and Ethernet connections to be used with external devices. TOOLS REQUIRED Small flat-blade screwdriver ADDITIONAL MATERIALS REQUIRED Power supply @150 ma per NGC-40-BRIDGE Custom built CAN cables with RJ-45 connections APPROVALS Shown not to scale Hazardous Locations Class I, Div. 2, Groups A,B,C,D T4 Class I, Zone 2, AEx nc IIC T4 IP20 Ex nl IIC T4 X 3128486 40 C Ta 65 C Certified to: CAN/CSA STD. C22.2 No. 213-M1987 (R2004) CAN/CSA STD. C22.2 No. 61010-1:2004 EN 61010-1 (2001) CAN/CSA STD. E60079-15:02 (R2006) Confms to: FM Class Number 3600 (11/98) FM Class Number 3611 (10/99) ANSI/UL STD. 60079-15-2009 UL STD. 61010-1 KIT CONTENTS Item Qty Description A 1 NGC-40-BRIDGE module B 2 CAN bus termination PTM# 10392-043 C 2 RS-485 termination resists 120 Ω 1% - 1/4 watt D 1 NGC-40-BRIDGE serial cable TTC# 10332-005 (Russia, Kazakhstan, Belarus) F other countries contact your local nvent representative. WARNG: This component is an electrical device that must be installed crectly to ensure proper operation and to prevent shock fire. F technical suppt, call nvent at (800) 545-6258.

GENERAL Supply voltage ± 10% Internal power consumption < 3.6 W per NGC-40-BRIDGE Ambient operating temperature 40ºC to 65ºC ( 40ºF to 149ºF) Ambient stage temperature 40ºC to 75ºC ( 40ºF to 167ºF) Environment PD2, CAT III Max. altitude 2,000 m (6,562 ft) Humidity 5 90% noncondensing Mounting Din Rail 35 mm ELECTROMAGNETIC COMPATIBILITY Emissions EN 61000-6-3 Emission standard f residential, commercial and light industrial environments Immunity EN 61000-6-2 Immunity standard f industrial environments COMMUNICATIONS COM1, COM2 Type 2-wire RS-485 Cable One shielded twisted pair Length 1,200 m (4,000 ft) maximum Quantity Up to 255 devices per pt Data rate 9600, 19.2K, 38.4K, 57.6K, 115.2K baud Data bits 7 8 Parity None, even, odd Stop bits 0, 1, 2 Tx delay 0 5 sec. Protocol Modbus RTU ASCII Connection terminals Wago cage clamp terminals COMMUNICATIONS COM3 Type RS-232 Cable Custom TTC# 10332-005 Length 15 m (50 ft) maximum Data rate 9600, 19.2K, 38.4K, 57.6K, 115.2K baud Data bits 7 8 Parity None, even, odd Stop bits 0, 1, 2 Tx delay 0 5 sec. Protocol Modbus RTU ASCII Connection terminals RJ-11 CAN NETWORKG PORT Type 2-wire isolated CAN-based peer-peer netwk. Isolated to 300 V. Connection Two 8-pin RJ-45 connects (both may be used f Input Output connections) Protocol Proprietary NGC-40 Topology Daisy chain Length 10 m (33 ft) maximum Quantity Up to 80 CAN nodes per netwk segment Address Unique, facty assigned ETHERNET Type Length Data rates Protocol Connection terminals PROGRAMMG AND SETTG LED indicats Alarm conditions Configuration switch CONNECTION TERMALS Wiring terminals CAN netwking and module power HOUSG Size 10/100 BaseT Ethernet netwk 100 m (328 ft) 10 100 MB/s Modbus/TCP Shielded 8-pin RJ-45 connect on front of module, Configuration lost, CAN communications fail SET/RUN slide switch on front of module Cage clamp, 0.5 to 2.5 mm² (24 to 12 AWG) Two RJ-45s, one each and. Provides CAN bus signals and power. 45.1 mm (1.78 in) wide x 87 mm (3.43 in) high x 106.4 mm (4.2 in) deep 2 nvent.com

System Components 45.1 mm (1.78 in) 45.1 mm (1.78 in) 45.1 mm (1.78 in) 45.1 mm (1.78 in) 87 mm (3.43 in) 106.4 mm (4.2 in) 87 mm (3.43 in) Front Top Bottom Back A. Wiring Terminals Terminals Function 1 COM 1 (485) in 2 COM 1 (485) out 3 COM 2 (485) in 4 COM 2 (485) out 5 COM 1 (485) in 6 COM 1 (485) out 7 COM 2 (485) in 8 COM 2 (485) out 9 12 Not used B. Status LEDs Status: Indicates status of the module Off No power Green OK/Nmal Yellow (flashing) Configuration mode Red (flashing) Internal fault Netwk: Indicates CAN netwk activity Off No link detected Green Link OK, receive data packets Yellow Transmit data packets Red (flashing) Netwk err COM: Indicates COM1 & 2 (RS-485) activity Off No activity Green (flashing) Receipt of data packet Yellow (flashing) Transmit of data packet C. Communication Slide Switch D. RS-232 Pt Status: Indicates status of RS-232 pt Top LED Off No activity Green (flashing) Receipt of data packet Bottom LED Off No activity Yellow (flashing) Transmit of data packet E. Ethernet Pt Status: Indicates status of the LAN Top LED Off No LAN detected Green ON, LAN detected Bottom LED Off No LAN activity Yellow (flashing) LAN activity (data packet) F. CAN Bus/ Power G. Reset Button nvent.com 3

Mounting the NGC-40-BRIDGE Each NGC-40-BRIDGE mounts on a D 35 rail. MOUNTG: Insert the rear bottom of the module into the D rail, then push up and inwards to engage the clip. REMOVAL: Push the module upwards to disengage the clip, then rotate the module toward you. 2 2 1 1 RS-485 Connection Diagrams Nth American Installation Technique COM 1&2 Connections (In) COM 1&2 Connections (Out) and RS-485 Resist Wiring f Com 1 & Com 2 must be terminated on a panel mounted terminal. No ground wires should be terminated on terminals 9 & 11. Terminate Com shields at the panel mounted field terminal chassis ground. Wiring f Com 1 & Com 2 must be terminated on a panel mounted terminal. No ground wires should be terminated on terminals 10 & 12. Terminate Com shields and 120 Ω termination resists (included) at the panel mounted field terminal as shown. COM 1 In COM 2 In 1 5 9 3 7 11 COM 1 Out 2 6 10 COM 2 Out 4 8 12 Field terminal To upstream device To upstream device Field terminal 120 ohm termination resist 120 ohm termination resist 4 nvent.com

RS-485 Connection Diagrams European Installation Technique COM 1&2 Connections (In) COM 1&2 Connections (Out) and RS-485 Resist Wiring f Com 1 & Com 2 must be terminated on a panel mounted terminal. No ground wires should be terminated on terminals 9 & 11. Terminate Com shields at the panel mounted field terminal chassis ground. The Com cable shield from the field terminal to the Bridge should be terminated at the earth ground bar. COM 1 In 1 5 9 To upstream device COM 2 In 3 7 11 Earth grounding bar located at the bridge module Field terminal Earth grounding bar located at the bridge module Wiring f Com 1 & Com 2 must be terminated on a panel mounted terminal. No ground wires should be terminated on terminals 10 & 12. Terminate Com shields and 120 Ω termination resists (included) at the panel mounted field terminal as shown. The Com cable shield from the field terminal to the Bridge should be terminated at the earth ground bar. COM 1 Out 2 6 10 120 ohm termination resist COM 2 Out 4 8 12 Earth grounding bar located at the bridge module Field terminal Earth grounding bar located at the bridge module 120 ohm termination resist To upstream device Local RS-232 (COM 3) & Ethernet Switch Setting RS-232 User Interface Configuration Switch A slide switch is provided on the front of the module to allow the user to set the bridge into a known state f configuration of the communication pts, as shown in the following table: Bridge Settings Switch Position SET Configuration mode RUN Nmal operating mode Modbus address 1 Local RS-232 RS-232 Local RS-232 to Laptop Protocol Data rate Data bits 8 RTU 9600 baud Settings based on the user configuration parameters Ethernet To upstream device Stop bits 2 Parity No parity nvent.com 5

RMM2 Connection Optional When using the field mounted RMM2 f RTD input, it must be connected to the COM 2 In as shown below. Panel COM 2 In 3 7 11 Earth grounding bar located at the bridge module Panel Terminal ~ ~ RS-485 Shielded Twisted Pair To next RMM2 ~ ~ Field 6 nvent.com

NGC-40 CAN Bus Connections f Up to 10 s CAN/Term Bridge 80 s per Bridge Primary Supply* 20 s Redundant Supply* 20 s 1 2 3 4 10 Optional redundant supply * Power supply shall have a means f disconnect from line voltage NGC-40 CAN Bus Connections f Up to 20 s CAN/Term Bridge 80 s per Bridge Primary Supply* 20 s Redundant Supply* 20 s 1 2 3 4 10 Optional redundant supply 11 12 13 14 20 * Power supply shall have a means f disconnect from line voltage nvent.com 7

CAN / TERM CAN / 24 VDC CAN Bus A termination (included) is required at each end of the CAN/ bus. See NGC-40 CAN bus connection wiring diagram f me details. CAN / TERM CAN / 24 VDC PTM /IO PTM /IO Provide Suitable Panel Enclosure and Determine Locations f NGC-40-BRIDGE Assembly in Panel* 1. Provide suitable panel enclosure The NGC-40-BRIDGE must be mounted in an enclosure to protect its electronic components. F indo applications, use a minimum NEMA 1 enclosure (NEMA 12 recommended). F outdo applications, use a NEMA 4 NEMA 4X enclosure depending on the requirements. Panel do PS1 PTM1 CBM 1 Panel 2 3 4 5 Note: The RAYCHEM NGC-40-BRIDGE is designed f operation in ambient temperatures from 40 C to 65 C ( 40 F to 149 F ). If the ambient temperature is outside this range, a space heater and/ cooling fan will be required in the panel. Alarm light PS2 PS3 C11 PTM3 C1 PTM2 C12 HTC11 C2 HTC1 C113 HTC12 C3 HTC2 C4 HTC13 C4 HTC3 C5 HTC14 C5 HTC4 C16 HTC15 C6 HTC5 C17 HTC16 C7 HTC6 C18 HTC17 C8 HTC7 C19 HTC18 C9 HTC8 C20 HTC19 C10 HTC9 HTC10 HTC20 2. Determine locations f the NGC-40-BRIDGE assembly in the electrical panel. PS4 PTM4 HTC21 HTC22 HTC23 HTC24 HTC25 HTC26 HTC27 HTC28 HTC29 HTC30 The NGC-40-BRIDGE should be located in the rear of the panel. The NGC-40-BRIDGE assembly is an electronic unit and must not be located where it will be exposed to strong magnetic fields excessive vibration. C21 C22 C23 C24 C25 C26 TB C27 C28 C29 C30 *Nth American panel installation techniques 8 nvent.com

NGC-40 CAN Bus Connections f Up to 40 s Primary Supply* 20 s CAN/Term s Redundant Supply* 20 s Optional redundant supply Bridge 80 s per Bridge 1 2 3 4 10 CAN/Term Bridge 80 s per Bridge 11 12 13 14 20 CAN/Term Board ) Primary Supply* 20 s Redundant Supply* 20 s 21 22 23 24 30 Optional redundant supply * Power supply shall have a means f disconnect from line voltage CAN/Term 31 32 33 34 40 nvent.com 9

Nth America Europe, Middle East, Africa Asia Pacific Latin America Tel 1.800.545.6258 Fax 1.800.527.5703 thermal.info@nvent.com Tel 32.16.213.511 Fax 32.16.213.604 thermal.info@nvent.com Tel 86.21.2412.1688 Fax 86.21.5426.3167 cn.thermal.info@nvent.com Tel 1.713.868.4800 Fax 1.713.868.2333 thermal.info@nvent.com nvent.com 2018 nvent. All nvent marks and logos are owned licensed by nvent Services GmbH its affiliates. All other trademarks are the property of their respective owners. nvent reserves the right to change specifications without notice. Raychem-IM-H58089-NGC40Bridge-EN-1805 PCN 1244-009547