CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

Similar documents
CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

kyalfa V- VDD/VDD6 General Contents

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

J&M Fluidics, Inc. Company Product Overview

Blue e+ chillers with the principle

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

2018 Product overview

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

GP SERIES Packaged Chillers

U-Match Series DC Inverter Service Manual PRODUCT

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Assembly and Maintenance

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

4-step Chiller and Heat Pump Controller

CTC Low Temperature Process Chillers

DUCTED SPLIT SYSTEMS With Scroll compressors

Product Data. 24ANA1 Infinityt 21 Series Air Conditioner with PuronR Refrigerant 2Through5NominalTons(Size24To60) INDUSTRY LEADING FEATURES / BENEFITS

CONDENSING UNITS UASL- JEC

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

DEDICATED HEAT RECOVERY UNIT (DHRC)

HIGH EFFICIENCY Central Chiller

FPS SERIES Super Slim Ceiling Mount Air Handling Units

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

IT Air Conditioning Units

HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED HEAT PUMP WITH OBSERVER

Ecotel Free Cool 5-15kW

Ceiling Concealed Split System C Series

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

MOLLIER DIAGRAM CAN BE IMPROVED!

SE7600E Series Application Guide

Semi-hermetic Air-cooled Condensing Units

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Room controller STRA-17

Huawei Smart Cooling Solution

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Ecoflair Air Economizers

Trailblazer AGZ-E air-cooled scroll chillers

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

Reliability and extended operation

SERVICE MANUAL VMF-E5

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert HPC Freecooling Chiller

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

Daikin McQuay. Enfinity Water Source Heat Pump Ceiling Mounted. WCCH, WCCW 072, 096, 120 Design 1

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Pressure switch KP. Data sheet

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

HYFRA Sigma. Efficient, reliable cooling water recooling systems. Customized. Cooling. Solutions.

Close-coupled cooling

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

DESIGN & TECHNICAL MANUAL

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

CTXA-AS/AT/AW, FTXA-AS/AT/AW

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

Aquaflair. BREC/F and BCEC/F kw

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

New Design Strategies for Energy Saving. Intelligent free-cooling

Product Data PH16NA FEATURES / BENEFITS. 16 SEER 2---Stage Split---System Heat Pump With R---410A Refrigerant 2 To 5 Tons ( ) AVAILABLE SIZES:

IT COOLING CHILLERS. AIR COOLED CHILLERS WITH FREE-COOLING TECHNOLOGY, FROM 302 TO 1649 kw

Transcription:

CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 -

FROM, KW TO KW. CHA/IK/WP A CLASS ENERGY EFFICIENCY AIRCOOLED REVERSIBLE HEAT PUMPS WITH EC INVERTER AXIAL FANS, INVERTER ROTARY/SCROLL COMPRESSOR, PLATE EXCHANGER AND HYDRONIC KIT. CHA/IK/WP reversible Heat Pumps with A CLASS energy efficiency are designed for small domestic or service sector environments. Equipped with R0A refrigerant, INVERTER Rotary/Scroll compressors and EC INVERTER axial fans, they are extremely functional and reliable units. The Inverter device controls and continuously modulates the compressor speed, keeping the temperature of the water delivered to the system stable and constant and adapting it perfectly to the thermal load of the places where terminal units it feeds are installed. This obtains high energy efficiencies and ESEER/IPLV values higher than conventional unit, and a reduction of compressor starting peak currents, thus considerably reducing the risk of malfunctioning or breakages. The EC Inverter axial fans vay their speed according to the required thermal load, with consequent benefits in terms of energy efficiency and silent operation. Moreover, CHA/IK/WP does not require inertial storage tanks, since the refrigerating capacity delivered is constantly equal to that required while guaranteeing very quiet operation because the fans adjust their speed to the real load of the system, with benefits above all during the night. It also prevents shutdown due to unexpected overloads, by means of an innovative control system which, on being activated, reduces the refrigerating capacity delivered while keeping the unit running. VERSION CHA/IK/WP Reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. DC INVERTER Rotary / Twin Rotary / Scroll compressor, complete with overload protection and crankase heater. EC INVERTER axial fans with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser with copper tube and aluminium finned coil, complete with drain pan and protection guards. Evaporator AISI stainless steel braze welded plates type, complete with water flow switch and antifreeze heater. Electronic thermostatic valve. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: modulating circulating pump with high efficiency DC Brushless motor, flow switch, safety valve, gauge and expansion vessel. Microprocessor control and regulation system. Communication with Modbus RTU protocol through RS8 serial. ACCESSORIES FACTORY FITTED ACCESSORIES KDS Dual set-point kit LOOSE ACCESSORIES CR Remote control panel AG Rubber shock absorbers

CHA/IK/WP MODEL Heating Heating (EN) (EN) Electrical characteristics Water circuit Heating capacity () kw. 8.9.8.9 Absorbed power () kw..8.. COP ().... Heating capacity () kw.9 9... Absorbed power () kw.... COP ().99.0.09.0 Heating capacity () kw. 8.8..8 Absorbed power () kw.... COP ()..0.. EUROVENT Class () A A A A Heating capacity () kw.8 9... Absorbed power () kw...0. COP ()..0.0.0 SCOP ().8..0.8 Energy Efficiency () % 0 0 0 00 Energy Class () A+ A+ A+ A+ capacity () kw.9.. 9.8 Absorbed power () kw.... EER ().8.9.8.8 capacity () kw.0 8...0 Absorbed power () kw...0. EER ()..9.8. capacity () kw.9..8 9.9 Absorbed power () kw..0.. EER ().0.0.98.9 ESEER..08.0.9 EUROVENT Class () B B B B capacity () kw. 8... Absorbed power () kw...9. EER ().0.8.0.8 Quantity n Type Rotary Twin Rotary Scroll Power supply V/Ph/Hz 0//0 00/+N/0 Max. running current A 0 Max. starting current A 8 0 0 Water flow l/s 0.8 0. 0.0 0.8 Pump available static kpa 8 Water connections G M M M M Sound STD version () db(a) 0 Transport weight Kg 0 8 0 Operating weight Kg 9 DIMENSIONS L STD mm 00 00 0 0 W STD mm 0 0 H STD mm 0 80 00 00 CLEARANCE AREA CHA/IK/WP 00 00 800 00 CHA/IK/WP 00 00 800 00 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Chilled water from to 8 C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. Electrical board side

FROM, KW TO KW. CHA/CLK 8 A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, ROTARY/SCROLL COMPRESSOR, PLATE EXCHANGER AND PUMP KIT. The COMPACT LINE series is the winning choice for ideal comfort in residential and commercial environments. The range, in A CLASS energy efficiency, excels for its compact sizes, quietness and optimised water circuit, on a peraluman structure. The COMPACT LINE series features R0A refrigerant, ensuring high efficiency with reduced heat exchange surfaces and environment respect thanks to the low quantities of refrigerant used. Particular design features enable immediate and effective use, easy installation and lasting reliability. These extremely compact and high-tech units offer you ideal comfort in all seasons. Particular design features enable immediate and effective use, easy installation and lasting reliability. VERSION CHA/CLK only with tank and pump CHA/CLK/WP Reversible Heat Pump with tank and pump FEATURES Structure with supporting frame, in peraluman, galvanized sheet and with rubber shock absorbers on the frame. Rotary / Scroll compressor with internal overheat protection and crankcase heater, if needed. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser in copper tubes and aluminium finned coil complete with drain pan for WP version only. Evaporator AISI stainless steel braze welded plates type, built-in the storage tank. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor contact and pump contact ( ). Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: water differential switch, insulated tank, circulating pump, safety valve, gauge and expansion vessel inserted in the storage tank. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES BT Low water temperature Kit TX Coil with pre-coated fins LOOSE ACCESSORIES CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards

CHA/CLK 8 MODEL 8 8 capacity () kw.... 8. 0... 8. 0. Absorbed power () kw.....9..0.0.0. EER ().00.00.0.00.9.9.0.0.0. capacity () kw.... 8. 0... 8.9 0.8 Absorbed power () kw...0..8..... (EN) EER ()..9.0...0...9. ESEER.0.......8.. EUROVENT Class A A A A A A A A A A Heating capacity () kw.0.0 8.0 8. 0...8 8.8.9. Heating Absorbed power () kw..0..9...8.. 8.0 COP ().9.00.08.00.9.9.08.0.08.0 Heating capacity () kw.9.9.9 8. 0... 8... Absorbed power () kw..0..8....9.9.8 COP ().99.98..0.0.0.... Heating (EN) EUROVENT Class C C B B B B A B B A SCOP ().9.0..9.00.99.0..8. () Energy Efficiency % 9 9 Energy Class () A A A+ A A A A A A+ A+ Quantity n Type Rotary Scroll Electrical current 9 8 8 characteristics Max. starting current A 8 88 8 8 Power supply Max. running V/Ph/Hz A 0//0 00/+N/0 Water flow l/s 0.0 0. 0. 0. 0. 0.0 0.8 0. 0.89 0.98 Water circuit Pump available static kpa 8 0 90 80 Tank water volume l 0 0 0 0 Water connections G / / / / / / Sound STD version () db(a) 9 9 9 9 Transport weight Kg 9 98 0 0 8 0 9 9 9 98 Operating weight Kg 8 DIMENSIONS 8 8 L STD mm 80 80 80 80 80 80 0 0 0 0 W STD mm 0 0 0 0 0 0 00 00 00 00 H STD mm 00 00 00 00 00 00 0 0 0 0 CLEARANCE AREA CHA/CLK 00 00 800 00 CHA/CLK 8 00 00 800 00 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP version are specified on technical brochure. Electrical board side

FROM KW TO KW. CHA/ML/ST A CLASS ENERGY EFFICIENCY AIRCOOLED DEDICATED HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSOR, PLATE EXCHANGER AND HYDRONIC KIT. MIDYLINE is the line of Heat Pumps dedicated to hot water production up to 0 C and operations up to -0 C external air temperature, with Scroll compressors, axial fans and integrated hydronic kit. The unit, featuring A CLASS energy efficiency, is designed to singly handle winter heating, summer air conditioning and the production of high temperature hot water, making use of the electrical energy and heat accumulated in the clean air source, free and infinite, which can also transfer heat to homes. Flexibility is the main feature of the MIDYLINE series, which is also combined with heating units and managed by the innovative, intelligent AQUALOGIK control system, optimizing the water setpoint and regulating power supply voltage to the pump and fans, making use of an inertial tank unnecessary. This results in performance with elevated energy efficiency, silent functioning, optimized dimensions and costs. MIDYLINE is also able to operate in extreme conditions where the external air temperature is very low, as well as intelligently managing integrated elements such as furnaces and electrical coils. Based on the external air sensor, the microprocessor activates the single integration elements in the system. VERSION CHA/ML/ST Heat Pump with AQUALOGIK technology CHA/ML/WP/ST Reversible Heat Pump with AQUALOGIK technology FEATURES Structure with supporting frame, in peraluman, galvanized sheet and with rubber shock absorbers on the frame. Scroll compressor with internal overheat protection and crankcase heater. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser with copper tube and aluminium finned coil, complete with drain pan. Evaporator AISI stainless steel braze welded plates type, completed with water differential switch and antifreeze heater. R0C refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: variable speed circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES EH Supplementary electrical heater KC Gas burner integration Kit TX Coil with pre-coated fins LOOSE ACCESSORIES HW Storage tank for domestic hot water production CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards

CHA/ML/ST MODEL * * ** ** Heating capacity () kw..0..0. Absorbed power () kw..... Heating COP ().9.8.9.8. Heating capacity () kw..8..8. Absorbed power () kw..8..8. COP ().9..9.. Heating capacity () kw.9..9..0 Absorbed power () kw..... COP ()..... Heating (EN) EUROVENT Class A A A A A SCOP ().9.0.9.0.8 Energy Efficiency () % 8 Energy Class () A++ A++ A++ A++ A+ capacity () kw. 0.. 0..0 Absorbed power () kw..... EER ().9.9.9.9.08 capacity () kw 0.8. 0.8.. Absorbed power () kw..0..0. EER ().00.88.00.88.8 capacity () kw.0 0..0 0.. Absorbed power () kw.8.9.8.9. (EN) EER ().0..0..9 ESEER.80..80.. EUROVENT Class E D E D C Quantity n Power supply V/Ph/Hz 0//0 Integrated electrical Heating capacity kw / / / / / coils Absorbed current A 8/ 8/ 8/ 8/ 8/ Steps n Electrical characteristics Power supply V/Ph/Hz 0//0 00/+N/0 Max. running current A 9 Max. starting current A 0 9 0 Water flow l/s 0. 0. 0. 0..0 Water circuit Pump available static kpa 8 8 Water connections G Sound STD version () db(a) Transport weight Kg 0 08 0 08 0 Operating weight Kg 09 09 DIMENSIONS * * ** ** L STD mm 0 0 0 0 0 W STD mm 00 00 00 00 00 H STD mm 0 0 0 0 0 CLEARANCE AREA CHA/ML/ST 00 00 800 00 Electrical board side NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at medium temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Chilled water from to 8 C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP version are specified on technical brochure. N.B. * = Single phase N.B. ** = Three phase

FROM KW TO KW. CHA/ML/ST 9 A CLASS ENERGY EFFICIENCY AIRCOOLED DEDICATED HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSOR, PLATE EXCHANGER AND HYDRONIC KIT. MIDYLINE, featuring A CLASS energy efficiency, is the innovative series of Heat Pumps dedicated to production of hot water up to 0 C and operation up to -0 C external air temperature, with Scroll compressors, axial fans and integrated hydronic unit. The unit, designed to originate and control throughout the year the best comfort conditions in rooms with a high rate of daily attendance, such as enclosed areas destined to the activities of the service sector, autonomously handles winter heating, summer air conditioning and the production of high temperature sanitary hot water. The MIDYLINE series, designed with an extremely compact structure for simple installation operations, uses only the electric energy and the heat accumulated in the air, to transfer heat to the rooms, thus allowing considerable energy savings, a high rate of reliability and the shortest start-up times. Flexibility is the main feature of the MIDYLINE series, which is indeed combined with terminal units and managed by the innovative, intelligent AQUALOGIK control and optimization system, which renders the use of an inertial tank unnecessary and guarantees performances with elevated energy efficiency and silent functioning. VERSION CHA/ML/ST Heat Pump with AQUALOGIK technology CHA/ML/WP/ST Reversible Heat Pump with AQUALOGIK technology FEATURES Structure with supporting frame, in peraluman and galvanized sheet. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type, completed with water differential switch and antifreeze heater. R0C refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: variable speed circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES EH Supplementary electrical heater KC Gas burner integration Kit TX Coil with pre-coated fins LOOSE ACCESSORIES HW Storage tank for domestic hot water production CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards AG Rubber shock absorbers 8

CHA/ML/ST 9 MODEL 9 0 Heating capacity () kw 0. 0.. Absorbed power () kw 8.0 0.9. Heating COP ().8.9.8 Heating capacity () kw 9.8 0.0 0. Absorbed power () kw. 9.. COP ()...0 Heating capacity () kw... Absorbed power () kw 8.0 0.9. COP ().9..9 Heating (EN) EUROVENT Class A A A SCOP ().9.. Energy Efficiency () % Energy Class () A++ A+ A+ capacity () kw 0. 8.9. Absorbed power () kw. 9.. EER ().09..9 capacity () kw. 9..8 Absorbed power () kw. 0..8 EER ().8.. capacity () kw 9.8 8.. Absorbed power () kw. 0.0. (EN) EER ()..8.9 ESEER... EUROVENT Class C C B Quantity n Power supply V/Ph/Hz 00//0 Integrated electrical Heating capacity kw /0 /0 /0 coils Absorbed current A / / / Steps n Electrical characteristics Power supply V/Ph/Hz 00/+N/0 Max. running current A 8 Max. starting current A 09 9 9 Water flow l/s..9. Water circuit Pump available static kpa 0 9 Water connections G Sound STD version () db(a) Transport weight Kg 0 Operating weight Kg 9 9 DIMENSIONS 9 0 L STD mm 80 80 80 W STD mm 000 000 000 H STD mm 00 00 00 CLEARANCE AREA CHA/ML/ST 9 00 800 800 800 Electrical board side NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at medium temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Chilled water from to 8 C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP version are specified on technical brochure. 9

FROM KW TO KW. CHA/ML/ST 8-P 0-P A CLASS ENERGY EFFICIENCY AIRCOOLED DEDICATED HEAT PUMPS WITH DOMESTIC HOT WATER PRODUCTION, AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGER AND HYDRONIC KIT. MIDYLINE, featuring A CLASS energy efficiency, is the innovative series of Heat Pumps dedicated to production of hot water up to 0 C and operation up to -0 C external air temperature, with Scroll compressors, axial fans and integrated hydronic unit. The unit, designed to originate and control throughout the year the best comfort conditions in rooms with a high rate of daily attendance, such as enclosed areas destined to the activities of the service sector, autonomously handles winter heating, summer air conditioning and the production of high temperature sanitary hot water. The MIDYLINE series, designed with an extremely compact structure for simple installation operations, uses only the electric energy and the heat accumulated in the air, to transfer heat to the rooms, thus allowing considerable energy savings, a high rate of reliability and the shortest start-up times. Flexibility is the main feature of the MIDYLINE series, which is indeed combined with terminal units and managed by the innovative, intelligent AQUALOGIK control and optimization system, which renders the use of an inertial tank unnecessary and guarantees performances with elevated energy efficiency and silent functioning. VERSION CHA/ML/ST Heat Pump with AQUALOGIK technology CHA/ML/WP/ST Reversible Heat Pump with AQUALOGIK technology CHA/ML/SSL/ST Super silenced Heat Pump with AQUALOGIK technology CHA/ML/WP/SSL/ST Super silenced reversible Heat Pump with AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with flow switch and antifreeze heater. R0C refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and pump, thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line DS Desuperheater KC Gas burner integration Kit SS TX IS Soft start Coil with pre-coated fins Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES HW Storage tank for domestic hot water production MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 0

CHA/ML/ST 8-P 0-P MODEL 8-P 0-P -P 0-P Heating Heating (EN) (EN) Electrical characteristics Water circuit Sound Heating capacity () kw. 8. 9. Absorbed power () kw. 0.8.. COP ()....8 Heating capacity () kw.. 9. Absorbed power () kw.... COP ().0.8.. Heating capacity () kw 8.0 9. 9. Absorbed power () kw. 0.8.. COP ()..8.. EUROVENT Class A A A A SCOP ()..9.8. Energy Efficiency () % 0 Energy Class () A++ A++ A++ A+ capacity () kw. 0. 8. 0 Absorbed power () kw...8 9. EER ().0...8 capacity () kw 0. 8.8 0 0 Absorbed power () kw 8.... EER ()..9.9.08 capacity () kw. 9.. 99. Absorbed power () kw... 0. EER ()...8. ESEER.08.99.8.9 EUROVENT Class D E F E Quantity n Refrigerant circuits n Capacity steps n Power supply V/Ph/Hz 00//0 Max. running current A 8 8 Max. starting current A 9 0 Water flow l/s.... Pump available static kpa 0 0 0 Water connections G ½ ½ ½ ½ STD version () db(a) 0 With SL accessory () db(a) 8 9 0 SSL version () db(a) 8 0 Transport weight Kg 8 8 9 Operating weight Kg 8 8 9 DIMENSIONS 8-P 0-P -P 0-P STD mm 0 0 0 0 L SSL mm 0 0 0 0 W STD/SSL mm 00 00 00 00 STD mm 90 0 0 0 H SSL mm 0 0 0 0 CLEARANCE AREA CHA/ML/ST 8-P 0-P 00 800 800 800 Electrical board side NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at medium temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Chilled water from to 8 C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure.

CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION Unit Page CHA/IK/A/WP 9 - CHA/K 9 - CHA/K/ST 9 8-9 CHA/K/FC 9 0 - CHA/IK/A -P -P - CHA/TK/A 8-P 0-P - CHA/K/A/WP 8-P 0-P - CHA/K/A/WP/ST 8-P 0-P 8-9 CHA/K 8-P 0-P 0 - CHA/K/ST 8-P 0-P - CHA/K/FC 8-P 0-P - CHA/K 8 0 - CHA/K/ST 8 0 8-9 CRA/K 80-8 CRA/K 8-P 0-P 8-8 CRA/K/ST 8-P 0-P 8-8 CRA/K 8 0 8-8 CRA/K/ST 8 0 88-89 CHA/IK/A -P -P 90-9 CHA/K/A/WP -P 0-P 9-9 CHA/K -P 0-P 9-9 CHA/K/FC -P 0-P 9-9 CHA/K 0 98-99 CHA/K/EP 8-P 9-P 00-0 CHA/K/EP 0-P 0-P 0-0 CHA/IY/EP 0 0-0 CHA/IY/WP 0 0-0 CHA/Y/A 0 80 08-09 CHA/Y 0-B 80-B 0 - CHA/Y/FC 0-B 00-B - CHA 0-V 0-V - CHA/FC 0-V 0-V - CHA/TTH 0-90- 8-9 CHA/TTH/FC 0-90- 0 - CHA/TTY 0-00- - CHA/TTY/FC 0-00- -

FROM KW TO 0 KW. CHA/IK/A/WP 9 A CLASS ENERGY EFFICIENCY AIRCOOLED REVERSIBLE HEAT PUMPS WITH AXIAL FANS, INVERTER SCROLL COMPRESSORS AND PLATE EXCHANGER. The reversible Heat Pumps of the CHA/IK/A/WP 9 series, with R0A refrigerant, are designed to satisfy the needs of medium-sized service sector or industrial ambients and feature A CLASS energy efficiency. They are used, combined with terminal units, for the heating or air conditioning of the rooms and can be supplied with Modbus RTU protocol through RS8 serial. Units are equipped with axial fans, Inverter Scroll compressors and plate-type exchangers. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/IK/A/WP Reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. DC INVERTER Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type, complete with water flow switch and antifreeze heater. Electronic thermostatic valve. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. Communication with Modbus RTU protocol through RS8 serial. ACCESSORIES FACTORY FITTED ACCESSORIES SL Unit silencement EC EC Inverter fans TX Coil with pre-coated fins PS Single circulating pump PSI Inverter single circulating pump LOOSE ACCESSORIES CR Remote control panel AG Rubber shock absorbers

CHA/IK/A/WP 9 MODEL 9 0 Heating Heating (EN) (EN) Evaporator Electrical characteristics Unit with pump Sound Heating capacity () kw... 9. Absorbed power () kw. 0... COP ()...8. Heating capacity () kw.9. 9.. Absorbed power () kw. 8...9 COP ()..9.0.0 Heating capacity () kw... 9. Absorbed power () kw. 9.9.. COP ().... EUROVENT Class () A A A A Heating capacity () kw..9 8..0 Absorbed power () kw. 8..9. COP ()..0.09. SCOP ().8.8.8.8 Energy Efficiency () % 00 00 00 00 Energy Class () A+ A+ A+ A+ capacity () kw 0.9..0. Absorbed power () kw. 9... EER ()..00.8.00 capacity () kw 0.. 8.. Absorbed power () kw.0 9..8. EER ()..98.8.9 capacity () kw.0...0 Absorbed power () kw. 8.9..8 EER ().8.09.9. ESEER.9.0.. EUROVENT Class () A B B A capacity () kw 0.. 8.8. Absorbed power () kw.8 8.9..9 EER ()..09.90. Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s.0...0 Pressure drops kpa 0 8 0 Water connections G Power supply V/Ph/Hz 00/+N/0 Max. running current A 8 Max. starting current A 8 Pump available static kpa 8 0 8 Water connections G STD version () db(a) 0 With SL accessory () db(a) 8 0 Transport weight Kg 0 0 0 Operating weight Kg 0 0 DIMENSIONS 9 0 L STD mm 00 00 00 00 W STD mm 00 00 00 00 H STD mm 0 0 0 0 CLEARANCE AREA CHA/IK/A/WP 9 80 000 00 00 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at medium temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Chilled water from to 8 C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. Electrical board side

FROM KW TO KW. CHA/K 9 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSOR AND PLATE EXCHANGER. The liquid Chillers and Heat Pumps of the CHA/K 9 series, with R0A refrigerant, are designed to satisfy the needs of small and medium domestic and service sector environments. With a peraluman structure corrosion-resistant over time, these units can be combined with terminal units or with intermediate heat exchangers for process cooling applications. Available in the versions with or without pumping kit, these units are equipped with particular technical and design adjustments that enable an immediate and efficient use, in addition to remarkably quiet operation. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/K only CHA/K/WP Reversible Heat Pump CHA/K/SP only with tank and pump CHA/K/WP/SP Reversible Heat Pump with tank and pump FEATURES Structure with supporting frame, in peraluman and galvanized sheet. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Water circuit for SP version includes: insulated tank, circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES BT Low water temperature Kit CC Condensing control down to -0 C TX Coil with pre-coated fins PS Single circulating pump FE Antifreeze heater for evaporator FA Antifreeze heater for tank LOOSE ACCESSORIES CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards AG Rubber shock absorbers

CHA/K 9 MODEL 9 0 capacity () kw.8 8... Absorbed power () kw 8. 0... EER ().99..8.9 capacity () kw. 8...9 (EN) Absorbed power () kw 8..0.9.8 EER ().90.8.8.8 ESEER..0..8 Heating capacity () kw 0.... Heating Absorbed power () kw 9..8.8. COP ()....0 Heating capacity () kw 0.... Absorbed power () kw 9.8.8.9. Heating (EN) COP ()....8 SCOP ()..08.8. Energy Efficiency () % 0 Energy Class () A A A+ A+ Quantity n Water flow l/s.8..0.0 Evaporator Pressure drops kpa 9 9 Water connections G Electrical characteristics Power supply V/Ph/Hz 00/+N/0 Max. running current A Max. starting current A 0 Unit with tank and Pump available static kpa 9 8 pump Tank water volume l 00 00 00 00 Water connections G Sound STD/SP version () db(a) Transport weight () Kg 0 9 Operating weight () Kg 8 8 8 DIMENSIONS 9 0 L STD/SP mm 80 80 80 80 W STD/SP mm 000 000 000 000 H STD/SP mm 00 00 00 00 CLEARANCE AREA CHA/K 9 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of WP versions are specified on technical brochure. Electrical board side

FROM KW TO KW. CHA/K/ST 9 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSOR, PLATE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. CHA/K/ST 9 series liquid Chillers and Heat Pumps, with R0A refrigerant and AQUALOGIK technology, are designed to meet the needs of small and medium-sized domestic or service sector ambients. With a corrosion-resistant peraluman structure, they are combined with terminal units and managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Particular design features enable immediate and effective use, easy installation and lasting reliability. A wide range of accessories, factory fitted or supplied separately, completes the outstanding versatility and functionality of the series. VERSION CHA/K/ST only with AQUALOGIK technology CHA/K/WP/ST Reversible Heat Pump with AQUALOGIK technology FEATURES Structure with supporting frame, in peraluman and galvanized sheet. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: variable speed circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES BT Low water temperature Kit TX Coil with pre-coated fins FE Antifreeze heater for evaporator LOOSE ACCESSORIES CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards AG Rubber shock absorbers 8

CHA/K/ST 9 MODEL 9 0 capacity () kw.8 8... Absorbed power () kw 8. 0... EER ().99..8.9 capacity () kw. 8...9 (EN) Absorbed power () kw 8..0.9.8 EER ().90.8.8.8 ESEER..0..8 Heating capacity () kw 0.... Heating Absorbed power () kw 9..8.8. COP ()....0 Heating capacity () kw 0.... Absorbed power () kw 9.8.8.9. Heating (EN) COP ()....8 SCOP ()..08.8. Energy Efficiency () % 0 Energy Class () A A A+ A+ Quantity n Power supply V/Ph/Hz 00/+N/0 Electrical Max. running current A 8 8 characteristics Max. starting current A 8 0 0 Water flow l/s.8..0.0 Water circuit Pump available static kpa 8 0 8 Water connections G Sound STD version () db(a) Transport weight Kg 0 80 9 Operating weight Kg 8 8 9 DIMENSIONS 9 0 L STD mm 80 80 80 80 W STD mm 000 000 000 000 H STD mm 00 00 00 00 CLEARANCE AREA CHA/K/ST 9 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP version are specified on technical brochure. Electrical board side 9

FROM 8 KW TO KW. CHA/K/FC 9 AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSOR AND PLATE EXCHANGER. The liquid Chillers of the CHA/K/FC 9 series, with R0A refrigerant, offer innovative technology to meet the needs of systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensing coil, thus saving energy by not operating the unit s Scroll compressors. A -way valve system is controlled by the electronic microprocessor controller, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE-COOLING) modes. VERSION CHA/K/FC only CHA/K/FC/SP only with tank and pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fan type with low ventilation and special wing profile, directly coupled to external rotor motors. Condenser made of FREE-COOLING copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type, complete with water differential switch. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit for SP version includes: insulated tank, circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES PS Single circulating pump BT Low water temperature Kit TX Coil with pre-coated fins LOOSE ACCESSORIES CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards AG Rubber shock absorbers 0

CHA/K/FC 9 MODEL 9 0 capacity () kw.9...8 Absorbed power () kw 9..0.9. EER ()..0..0 Free- cycle Air temperature () C -. -. 0. -. Absorbed power () kw 0.98 0.98.9.9 Quantity n Water flow l/s...0. Water circuit Pressure drops kpa Water connections G Electrical characteristics Power supply V/Ph/Hz 00/+N/0 Max. running current A 0 9 Max. starting current A 0 Unit with tank and Pump available static kpa 09 0 9 pump Tank water volume l 0 0 0 0 Water connections G Sound STD/SP version () db(a) Transport weight () Kg 0 0 8 Operating weight () Kg 99 DIMENSIONS 9 0 L STD/SP mm 80 80 80 80 W STD/SP mm 900 900 900 900 H STD/SP mm 80 80 80 80 CLEARANCE AREA CHA/K/FC 9 00 800 800 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at which the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. Electrical board side

FROM 0 KW TO 9 KW. CHA/IK/A -P -P A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, INVERTER SCROLL COMPRESSORS, MICROCHANNEL CONDENSING COILS AND PLATE EXCHANGER. The A CLASS energy efficiency liquid Chillers of the CHA/IK/A -P -P series, with R0A refrigerant, are designed to satisfy the needs of medium-sized service sector or industrial ambients. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with axial fans, Inverter Scroll compressors, Microchannel condensing coils and plate-type exchanger, even in the super silent version. The Microchannel condensing coils ensure an high efficiency (high EER), having a better heat exchange than traditional coils. A better efficiency at partial loads (ESEER/IPLV) is guaranteed by the Inverter control on Scroll compressor. Furthermore, Inverter control is also available on circulating pump and fans (EC Inverter) for a further efficiency improvement. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/IK/A only CHA/IK/A/SSL Super silenced cooling only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. DC INVERTER Scroll and ON-OFF Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of aluminium MICROCHANNEL condensing coils. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 9-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P -P models, complete with water differential switch. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans DS RT TXB PS PSI PD PDI FE IS ISB ISBT ISL Desuperheater Total heat recovery Coil with epoxy treatment Single circulating pump Inverter single circulating pump Double circulating pump Inverter double circulating pump Antifreeze heater for evaporator Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/IK/A -P -P MODEL -P 9-P -P -P -P 0-P -P -P 8-P -P (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 9.9...8 8.9 9. 0 9 Absorbed power () kw..9 0... 0.0. 0...0 EER ()....0...... capacity () kw 9.... 8. 9. 9 8 Absorbed power () kw. 8. 0..8. 0.. 0... EER ()...9...9.8..9.0 ESEER...0.0.9..0.0.0.0 EUROVENT Class A A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s.8....0.... 8. Pressure drops kpa 0 9 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 9 89 89 9 Max. starting current A 8 8 8 0 0 9 Pump available static kpa 0 0 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) With SL accessory () db(a) 9 9 9 9 0 0 0 0 SSL version () db(a) --- --- Transport weight Kg 8 0 8 0 0 9 Operating weight Kg 90 0 0 0 0 80 00 00 00 0 DIMENSIONS -P 9-P -P -P -P 0-P -P -P 8-P -P STD mm 0 0 0 0 0 0 0 0 00 00 L SSL mm 0 0 0 0 0 0 00 00 --- --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 STD mm 90 0 0 0 0 90 0 0 0 0 H SSL mm 90 0 0 90 90 0 0 0 --- --- CLEARANCE AREA CHA/IK/A -P -P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side

FROM KW TO 8 KW. CHA/TK/A 8-P 0-P A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, DIGITAL SCROLL COMPRESSORS, MICROCHANNEL CONDENSING COILS AND PLATE EXCHANGER. The A CLASS energy efficiency liquid Chillers of the CHA/TK/A 8-P 0-P series, with R0A refrigerant, are designed to satisfy the needs of medium-sized service sector or industrial ambients. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with axial fans, Digital Scroll compressors, Microchannel condensing coils and plate-type exchanger, even in the super silent version. The Microchannel condensing coils ensure an high efficiency (high EER), having a better heat exchange than traditional coils. A better efficiency at partial loads (ESEER/IPLV) is guaranteed by the Digital Scroll technology on compressor. Furthermore, Inverter control is available on circulating pump and fans (EC Inverter) for a further efficiency improvement. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/TK/A only CHA/TK/A/SSL Super silenced cooling only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. DIGITAL Scroll and ON-OFF Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of aluminium MICROCHANNEL condensing coils. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans DS RT TXB PS PSI PD PDI FE IS ISB ISBT ISL Desuperheater Total heat recovery Coil with epoxy treatment Single circulating pump Inverter single circulating pump Double circulating pump Inverter double circulating pump Antifreeze heater for evaporator Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/TK/A 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw. 9. 8.9 9. 90. 0 0 8 Absorbed power () kw. 8...9 8.... 9. 8. EER ().9.9.8.8.0.0.8.8.. capacity () kw. 9.0 8. 8.8 90. 0 9 8 Absorbed power () kw. 9.0.0. 8.8. 8..8 0. 9. EER ().........0. ESEER.89.90.9.8.89.9..89..99 EUROVENT Class A A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s..8.9.8..9...0 8.8 Pressure drops kpa 0 8 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 8 8 8 0 Max. starting current A 8 9 00 9 80 Pump available static kpa 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) With SL accessory () db(a) 9 9 9 9 0 0 0 0 SSL version () db(a) --- --- Transport weight Kg 9 0 0 8 9 98 9 9 Operating weight Kg 0 0 00 0 0 80 990 000 80 0 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P STD mm 0 0 0 0 0 0 0 0 00 00 L SSL mm 0 0 0 0 0 0 00 00 --- --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 STD mm 90 0 0 0 0 90 0 0 0 0 H SSL mm 90 0 0 90 90 0 0 0 --- --- CLEARANCE AREA CHA/TK/A 8-P 0-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side

FROM KW TO 9 KW. CHA/K/A/WP 8-P 0-P A CLASS ENERGY EFFICIENCY AIRCOOLED REVERSIBLE HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The reversible Heat Pumps of the CHA/K/A/WP 8-P 0-P series, with R0A refrigerant, are designed for medium-sized service sector or industrial ambients and feature A CLASS energy efficiency. They are used, combined with terminal units, for the heating or air conditioning of the rooms and can be supplied with Modbus RTU protocol through RS8 serial. Equipped with axial fans, Scroll compressors and plate-type exchanger, even in the super silent version, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/K/A/WP Reversible Heat Pump CHA/K/A/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins SI Inertial tank PS PD FA SS IS Single circulating pump Double circulating pump Antifreeze heater for tank Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/K/A/WP 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P Heating Heating (EN) (EN) Evaporator Electrical characteristics Unit with tank and pump Sound Heating capacity () kw... 8. 9. 09 9 Absorbed power () kw.9 9..8. 8.... 9.9 9.0 COP ().0..8.....9.. Heating capacity () kw.0.9. 8.9 9. 09 98 Absorbed power () kw. 9.8..8 8...8. 0.9 0. COP ()....0...8...9 EUROVENT Class A A A A A A A A A A SCOP ()..8.0.8.8..... Energy Efficiency () % 0 9 Energy Class () A+ A+ A+ A+ - - - - - - capacity () kw 8..9..9 8. 9. 08 9 Absorbed power () kw.8 8. 0.. 8..0..8 8.0. EER ().0.9.0.0.89.9.0.99.90.8 capacity () kw 8.0... 8.0 9. 08 8 0 Absorbed power () kw.0 9.0.0.0 8.8..0. 8.. EER ().00.8.9.98.8.9.00.9.8.9 ESEER..0..8.90.8...8. EUROVENT Class B C B B C B B B C C Quantity n Refrigerant circuits n Capacity steps n Water flow l/s.0..99..9...9..9 Pressure drops kpa 8 0 8 8 9 9 8 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 8 8 0 09 Max. starting current A 0 0 9 09 9 9 Pump available static kpa 0 0 0 0 0 0 0 Tank water volume l 00 00 00 00 00 00 00 00 00 00 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) With SL accessory () db(a) 9 9 9 9 0 0 0 0 SSL version () db(a) 8 Transport weight () Kg 9 0 80 9 0 Operating weight () Kg 0 0 00 0 80 90 090 0 0 0 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 00 00 00 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 0 0 0 0 0 0 0 CLEARANCE AREA CHA/K/A/WP 8-P 0-P 00 800 800 800 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of SSL version are specified on technical brochure. Electrical board side

FROM KW TO 9 KW. CHA/K/A/WP/ST 8-P 0-P A CLASS ENERGY EFFICIENCY AIRCOOLED REVERSIBLE HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. CHA/K/A/WP/ST 8-P 0-P series reversible Heat Pumps, with R0A refrigerant, AQUALOGIK technology and A CLASS energy efficiency, are designed for medium-sized service sector or industrial-type ambients. They are used, together with terminal units, for the heating or air conditioning of rooms and are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with axial fans, Scroll compressors and plate-type exchanger, even in the super silent version, they are complete with a hydronic unit. A wide range of accessories, factory fitted or supplied separately, completes the extreme versatility and functionality of this range. VERSION CHA/K/A/WP/ST Reversible Heat Pump with AQUALOGIK technology CHA/K/A/WP/SSL/ST Super silenced reversible Heat Pump with AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system with AQUALOGIK technology. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins SS IS Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 8

CHA/K/A/WP/ST 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P Heating Heating (EN) (EN) s Electrical characteristics Water circuit Sound Heating capacity () kw... 8. 9. 09 9 Absorbed power () kw.9 9..8. 8.... 9.9 9.0 COP ().0..8.....9.. Heating capacity () kw.0.9. 8.9 9. 09 98 Absorbed power () kw. 9.8..8 8...8. 0.9 0. COP ()....0...8...9 EUROVENT Class A A A A A A A A A A SCOP ()..8.0.8.8..... Energy Efficiency () % 0 9 Energy Class () A+ A+ A+ A+ - - - - - - capacity () kw 8..9..9 8. 9. 08 9 Absorbed power () kw.8 8. 0.. 8..0..8 8.0. EER ().0.9.0.0.89.9.0.99.90.8 capacity () kw 8.0... 8.0 9. 08 8 0 Absorbed power () kw.0 9.0.0.0 8.8..0. 8.. EER ().00.8.9.98.8.9.00.9.8.9 ESEER..0..8.90.8...8. EUROVENT Class B C B B C B B B C C Quantity n Refrigerant circuits n Capacity steps n Power supply V/Ph/Hz 00//0 Max. running current A 9 8 8 0 Max. starting current A 8 0 0 9 80 Water flow l/s.0..99..9...9..9 Pump available static kpa 0 0 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) With SL accessory () db(a) 9 9 9 9 0 0 0 0 SSL version () db(a) 8 Transport weight Kg 0 9 08 8 9 09 Operating weight Kg 8 80 90 0 0 0 0 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 00 00 00 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 0 0 0 0 0 0 0 CLEARANCE AREA CHA/K/A/WP/ST 8-P 0-P 00 800 800 800 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 9

FROM 8 KW TO 8 KW. CHA/K 8-P 0-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The liquid Chillers and Heat Pumps of the CHA/K 8-P 0-P series, with R0A refrigerant, are designed for medium-sized service sector or industrial ambients. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with axial fans, Scroll compressors and plate-type exchanger, even in the super silent version, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/K only CHA/K/WP Reversible Heat Pump CHA/K/SSL Super silenced cooling only CHA/K/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins SI Inertial tank PS PD FE FA SS IS Single circulating pump Double circulating pump Antifreeze heater for evaporator Antifreeze heater for tank Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 0

CHA/K 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw..9..9 8. 9.9 0 8 Absorbed power () kw. 8.8.8.0 8...9. 0. 8. EER ().9.9.9.9.9.0.90.9.9.0 capacity () kw.... 8.9 9. 0 Absorbed power () kw. 9... 8.. 8..9 0.9 9. EER ().88.8.8.8.89.9.8.8.88.99 ESEER...0..8..0... Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw. 9... 8.8. 8..8 0. 0. COP ()...09.....08.0.0 Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw. 9... 8.8. 8..8 0. 0. COP ()...09.....08.0.0 SCOP ()..9..8..8...0.8 Energy Efficiency () % 0 8 Energy Class () A+ A+ A+ A+ - - - - - - Quantity n Refrigerant circuits n Capacity steps n Water flow l/s...0.8.98.8..0.0 8.9 Pressure drops kpa 8 8 8 8 8 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 8 9 8 98 0 Max. starting current A 0 0 9 09 9 Pump available static kpa 0 0 0 0 0 0 0 0 0 00 Tank water volume l 00 00 00 00 00 00 00 00 00 00 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 0 0 0 0 With SL accessory () db(a) 8 8 8 8 9 9 9 9 SSL version () db(a) --- Transport weight () Kg 9 8 9 88 9 0 Operating weight () Kg 00 0 0 90 800 890 90 00 0 90 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 0 0 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 90 0 0 0 0 0 0 CLEARANCE AREA CHA/K 8-P 0-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side

FROM 8 KW TO 8 KW. CHA/K/ST 8-P 0-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. CHA/K/ST 8-P 0-P series liquid Chillers and Heat Pumps, with R0A refrigerant and AQUALOGIK technology, are designed for medium-sized service sector or industrial-type ambients. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes. They are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with axial fans, Scroll compressors and plate-type exchanger, even in the super silent version, they are complete with a hydronic unit. A wide range of accessories, factory fitted or supplied separately, completes the extreme versatility and functionality of this range. VERSION CHA/K/ST only with AQUALOGIK technology CHA/K/WP/ST Reversible Heat Pump with AQUALOGIK technology CHA/K/SSL/ST Super silenced cooling only with AQUALOGIK technology CHA/K/WP/SSL/ST Super silenced reversible Heat Pump with AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT FE TX SS IS Total heat recovery Antifreeze heater for evaporator Coil with pre-coated fins Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/K/ST 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P (EN) Heating Heating (EN) s Electrical characteristics Water circuit Sound capacity () kw..9..9 8. 9.9 0 8 Absorbed power () kw. 8.8.8.0 8...9. 0. 8. EER ().9.9.9.9.9.0.9.9.9.0 capacity () kw.... 8.9 9. 0 Absorbed power () kw. 9... 8.. 8..9 0.9 9. EER ().88.8.8.8.89.9.8.8.88.99 ESEER...0..8..0... Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw. 9... 8.8. 8..8 0. 0. COP ()...09.....08.0.0 Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw. 9... 8.8. 8..8 0. 0. COP ()...09.....08.0.0 SCOP ()..9..8..8...0.8 Energy Efficiency () % 0 8 Energy Class () A+ A+ A+ A+ - - - - - - Quantity n Refrigerant circuits n Capacity steps n Power supply V/Ph/Hz 00//0 Max. running current A 9 8 8 0 0 Max. starting current A 8 0 0 80 Water flow l/s...0.8.98.8..0.0 8.9 Pump available static kpa 0 0 0 00 0 0 0 9 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 0 0 0 0 With SL accessory () db(a) 8 8 8 8 9 9 9 9 SSL version () db(a) --- Transport weight Kg 0 9 8 9 80 898 9 0 9 Operating weight Kg 8 0 8 90 90 00 0 0 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 0 0 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 90 0 0 0 0 0 0 CLEARANCE AREA CHA/K/ST 8-P 0-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side

FROM KW TO KW. CHA/K/FC 8-P 0-P AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The liquid Chillers of the CHA/K/FC 8-P 0-P series, with R0A refrigerant, offer innovative technology for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in the FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensing coil, thus saving energy by not operating the unit s Scroll compressors. A -way valve system is controlled by the electronic microprocessor controller, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE-COOLING) modes. VERSION CHA/K/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. R0A refrigerant. Digital high and low gauges. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans TX Coil with pre-coated fins SI Inertial tank PS Single circulating pump PD Double circulating pump SS IS ISB ISBT ISL Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/K/FC 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P Free- cycle Water circuit Electrical characteristics Unit with tank and pump Sound capacity () kw. 9. 8.. 8. 99. 0 Absorbed power () kw 8. 0... 9..8. 8...9 EER ().9.9.9.9.9.9.0.9.8.8 Air temperature () C.. 0.0 -. -..0 0.0 -. -.0 -.8 Absorbed power () kw 8 8 Quantity n Refrigerant circuits n Capacity steps n Water flow l/s..0..9..09.88.0.8 8.9 Pressure drops kpa 0 0 00 00 00 0 0 Water connections G ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 8 8 0 Max. starting current A 0 0 9 09 0 9 80 Pump available static kpa 0 9 Tank water volume l 00 00 00 00 00 00 00 00 00 00 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 9 9 9 9 9 0 0 0 With SL accessory () db(a) 8 8 8 9 9 Transport weight () Kg 9 9 9 980 999 08 0 0 Operating weight () Kg 90 980 000 00 00 90 00 0 00 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD mm 0 0 0 0 0 00 00 00 00 00 W STD mm 00 00 00 00 00 00 00 00 00 00 H STD mm 0 0 0 0 0 CLEARANCE AREA CHA/K/FC 8-P 0-P 00 800 800 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at which the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. Electrical board side

FROM 9 KW TO 9 KW. CHA/K 8 0 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND SHELL AND TUBE EXCHANGER. The liquid Chillers and Heat Pumps of the CHA/K 8 0 series, with R0A refrigerant, are designed for medium-sized service sector or industrial ambients. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with axial fans, Scroll compressors and shell and tube exchanger, even in the super silent version, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/K only CHA/K/WP Reversible Heat Pump CHA/K/SSL Super silenced cooling only CHA/K/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Shell and tube type evaporator with one circuit on the refrigerant side and one on the water side in 8 models; with two independent circuits on the refrigerant side and one on the water side in 0 models, complete with water differential switch. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU PD SPU SPD FE FB SS IS Single circulating pump Double circulating pump Inertial tank and single circulating pump Inertial tank and double circulating pump Antifreeze heater for evaporator Antifreeze heater for evaporator and tank Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/K 8 0 MODEL 8 0 0 9 0 (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 9.0.0.. 8. 9. 09 9 9 9 Absorbed power () kw. 8.8.. 8.... 0. 8.8 EER ().9.9.90.90.9.0.9.9.9.0 capacity () kw 8.8..0.8 8.9 9. 08 8 8 8 Absorbed power () kw.8 9..9.8 9.0. 8... 9. EER ().90.8.8.8.89.9.8.89.88.99 ESEER....0.8.0.... Heating capacity () kw..9 0. 80. 9. 0 9 88 Absorbed power () kw.8 9..8. 9.. 8....0 COP ()...08.....0.0.08 Heating capacity () kw.0. 0. 8. 9.9 0 0 8 89 Absorbed power () kw 8.0 0.0.. 9.8. 9.... COP ()...0.0.08.0.0.0.00.0 SCOP ()..9.......0. Energy Efficiency () % 0 8 Energy Class () A+ A+ A+ A+ - - - - - - Quantity n Refrigerant circuits n Capacity steps n Water flow l/s..0.9..98.0..09.0 8. Pressure drops kpa 9 0 0 9 8 Water connections G ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 8 9 8 98 0 Max. starting current A 0 0 9 09 9 Pump available static kpa 0 0 00 0 0 0 0 Tank water volume l 0 0 0 0 0 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 0 0 0 0 With SL accessory () db(a) 8 8 8 8 9 9 9 9 SSL version () db(a) --- Transport weight () Kg 0 9 8 9 9 9 8 Operating weight () Kg 0 80 0 0 80 90 000 0 0 0 DIMENSIONS 8 0 0 9 0 L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 0 0 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 90 0 0 0 0 0 0 CLEARANCE AREA CHA/K 8 0 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side

FROM 9 KW TO 9 KW. CHA/K/ST 8 0 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS, SHELL AND TUBE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. CHA/K/ST 8 0 series liquid Chillers and Heat Pumps, with R0A refrigerant and AQUALOGIK technology, are designed for medium-sized service sector or industrial-type ambients. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes. They are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with axial fans, Scroll compressors and shell and tube exchanger, even in the super silent version, they are complete with a hydronic unit. A wide range of accessories, factory fitted or supplied separately, completes the extreme versatility and functionality of this range. VERSION CHA/K/ST only with AQUALOGIK technology CHA/K/WP/ST Reversible Heat Pump with AQUALOGIK technology CHA/K/SSL/ST Super silenced cooling only with AQUALOGIK technology CHA/K/WP/SSL/ST Super silenced reversible Heat Pump with AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser with copper tube and aluminium finned coil. Shell and tube type evaporator with one circuit on the refrigerant side and one on the water side in 8 models; with two independent circuits on the refrigerant side and one on the water side in 0 models, complete with water differential switch. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S HRT/P TX FE SS IS Total heat recovery in series Total heat recovery in parallel Coil with pre-coated fins Antifreeze heater for evaporator Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 8

CHA/K/ST 8 0 MODEL 8 0 0 9 0 (EN) Heating Heating (EN) s Electrical characteristics Water circuit Sound capacity () kw 9.0.0.. 8. 9. 09 9 9 9 Absorbed power () kw. 8.8.. 8.... 0. 8.8 EER ().9.9.90.90.9.0.9.9.9.0 capacity () kw 8.8..0.8 8.9 9. 08 8 8 8 Absorbed power () kw.8 9..9.8 9.0. 8... 9. EER ().90.8.8.8.89.9.8.89.88.99 ESEER....0.8.0.... Heating capacity () kw..9 0. 80. 9. 0 9 88 Absorbed power () kw.8 9..8. 9.. 8....0 COP ()...08.....0.0.08 Heating capacity () kw.0. 0. 8. 9.9 0 0 8 89 Absorbed power () kw 8.0 0.0.. 9.8. 9.... COP ()...0.0.08.0.0.0.00.0 SCOP ()..9.......0. Energy Efficiency () % 0 8 Energy Class () A+ A+ A+ A+ - - - - - - Quantity n Refrigerant circuits n Capacity steps n Power supply V/Ph/Hz 00//0 Max. running current A 9 8 8 0 0 Max. starting current A 8 0 0 80 Water flow l/s..0.9..98.0..09.0 8. Pump available static kpa 0 0 00 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 0 0 0 0 With SL accessory () db(a) 8 8 8 8 9 9 9 9 SSL version () db(a) --- Transport weight Kg 80 90 990 0 0 0 Operating weight Kg 0 90 0 0 8 90 00 0 0 0 DIMENSIONS 8 0 0 9 0 L STD mm 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 0 0 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 90 0 0 0 0 0 0 CLEARANCE AREA CHA/K/ST 8 0 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side 9

FROM, KW TO KW. CRA/K AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, ROTARY/SCROLL COMPRESSOR AND PLATE EXCHANGER. The indoor liquid Chillers and Heat Pumps of the CRA/K series, with R0A refrigerant, are designed for small and medium domestic or service sector systems with particular difficulty in positioning units outside the building. With a prepainted plate structure, these units can be combined with terminal units or with intermediate heat exchangers for process cooling applications. Available in the versions with or without pumping kit, these units are equipped with particular technical and design adjustments that enable an immediate and efficient use, in addition to remarkably quiet operation and a significant useful head of the fan. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CRA/K only CRA/K/WP Reversible Heat Pump CRA/K/SP only with tank and pump CRA/K/ WP/SP Reversible Heat Pump with tank and pump FEATURES Self-supporting prepainted steel frame. Rotary/Scroll compressor with internal overheat protection and crankcase heater, if needed. Double inlet radial type fan statically and dynamically balanced directly driven by a electric motor ( 8) or belt driven connected to a threephase electric motor (9 ). Condenser in copper tubes and aluminium finned coil complete with drain pan for WP version only. Evaporator AISI stainless steel braze welded plates type, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical panel includes: main switch with door lock device, fuses, compressor and pump remote control switch ( ). Water circuit for SP version includes: insulated tank, circulating pump, safety valve, gauge and expansion vessel. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES BT Low water temperature Kit CC Condensing control down to -0 C TX Coil with pre-coated fins PS Single circulating pump FE Antifreeze heater for evaporator FA Antifreeze heater for tank LOOSE ACCESSORIES CR Remote control panel IS Modbus RTU protocol, RS8 serial RP Coil protection metallic guards AG Rubber shock absorbers 80

CRA/K MODEL 8 (EN) Heating Heating (EN) Evaporator Available static CLEARANCE AREA capacity () kw.... 8. 0.. Absorbed power () kw..8...0..8 EER ().80.8.9.88.8.89. capacity () kw.... 8. 0.. Absorbed power () kw..9.....9 EER ()...8.8..8. ESEER..9....8.8 Heating capacity () kw.0.0 8.0 8. 0...8 Absorbed power () kw.9..8.... COP ()...8.8.8.8. Heating capacity () kw.0.0 8.0 8. 0...8 Absorbed power () kw.9..8.... COP ()...8.8.8.8. SCOP ().9.9.9.9.9.9.9 Energy Efficiency () % Energy Class () A A A A A A A Type Rotary Scroll Quantity n Water flow l/s 0.0 0. 0. 0. 0. 0.0 0.8 Pressure drops kpa 8 0 9 Water connections G Electrical board side STD version Pa 90 90 80 80 80 80 Electrical Power supply V/Ph/Hz 0//0 00/+N/0 Max. running current A 0 characteristics Max. starting current A 0 8 89 Unit with tank and Pump available static kpa 0 0 pump Tank water volume l 0 0 0 0 0 0 0 Water connections G Sound STD/SP version () db(a) 9 9 9 9 Transport weight () Kg 8 9 9 00 Operating weight () Kg 9 0 0 0 MODEL 8 9 0 (EN) Heating Heating (EN) Evaporator Available static capacity () kw. 8. 0..8 8.. Absorbed power () kw.8.8. 0.0.9. EER ()....8.0. capacity () kw. 8. 0.. 8.. Absorbed power () kw.9.9. 0...9 EER ().8..9...9 ESEER.8.0.0..9.0 Heating capacity () kw 8.8.9. 0... Absorbed power () kw.0.9 8.8..0.8 COP ().9...8.8.8 Heating capacity () kw 8.8.9. 0... Absorbed power () kw.0.9 8.8..0.8 COP ().9....8.8 SCOP ().9.0.00.9.98.98 Energy Efficiency () % 9 Energy Class () A A A A A A Type Scroll Quantity n Water flow l/s 0. 0.89 0.98.8..0 Pressure drops kpa 9 Water connections G STD version Pa 0 0 0 Electrical Power supply V/Ph/Hz 00/+N/0 Max. running current A characteristics Max. starting current A 8 Unit with tank and Pump available static kpa 08 0 8 pump Tank water volume l 0 0 0 0 0 0 Water connections G Sound STD/SP version () db(a) Transport weight () Kg 0 9 0 Operating weight () Kg 8 DIMENSIONS 8 8 9 0 L STD/SP mm 900 900 900 900 900 900 900 900 900 900 00 00 00 W STD/SP mm 0 0 0 0 0 0 90 90 90 90 800 800 800 H STD/SP mm CRA/K 00 800 800 800 CRA/K 8 00 800 800 000 CRA/K 9 00 800 800 00 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Efficienza energetica stagionale riscaldamento d ambiente a bassa temperatura in condizioni climatiche average secondo il Regolamento UE n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of WP versions are specified on technical brochure. 8

FROM 8 KW TO 8 KW. CRA/K 8-P 0-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The indoor liquid Chillers and Heat Pumps of the CRA/K 8-P 0-P series, with R0A refrigerant, are designed for medium-sized service sector or industrial systems with particular difficulty in positioning units outside the building. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with radial fans, Scroll compressors and plate-type exchanger, even in the version with high ESP fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CRA/K only CRA/K/WP Reversible Heat Pump CRA/K/AP only with high ESP fans CRA/K/WP/AP Reversible Heat Pump with high ESP fans FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Radial type fans coupled to -phase motors by V belt and variable pulley. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CC Condensing control down to -0 C BT Low water temperature Kit DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins SI Inertial tank PS Single circulating pump PD Double circulating pump FE FA SS IS Antifreeze heater for evaporator Antifreeze heater for tank Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 8

CRA/K 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P (EN) Heating Heating (EN) Evaporator Available static Electrical characteristics Unit with tank and pump Sound capacity () kw..9..9 8. 9.9 0 8 Absorbed power () kw.0 0... 0..8.9..0. EER ().80.9....8..8.. capacity () kw.... 8.9 9.8 0 Absorbed power () kw. 0.8..9... 8.0.8. EER ().0...0..0.8... ESEER.9.0.98.0.0...9.8.8 Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw 8....8..8..8..8 COP ().9.90.80.89.90.9.8.8..80 Heating capacity () kw..0. 80. 90. 0 0 8 Absorbed power () kw 8...8 8....9 8..0. COP ().9.80.8.8.88.88.80.80.. SCOP ()...0....0.0.0.0 Energy Efficiency () % 8 0 Energy Class () A+ A A A A - - - - - Quantity n Refrigerant circuits n Capacity steps n Water flow l/s...0.8.98.8..0.0 8.9 Pressure drops kpa 8 8 0 8 8 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version Pa 0 0 0 90 0 High ESP version Pa 98 88 --- --- 00 --- Power supply V/Ph/Hz 00//0 Max. running current A 8 8 9 90 0 Max. starting current A 9 0 0 0 89 Pump available static kpa 0 0 0 0 0 0 0 0 0 00 Tank water volume l 00 00 00 00 00 00 00 00 00 00 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) STD version with SL accessory () db(a) High ESP version () db(a) 8 --- --- 8 --- High ESP version with SL accessory () db(a) --- --- --- Transport weight () Kg 8 8 98 99 0 0 Operating weight () Kg 0 80 90 90 00 0 0 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD/AP mm 0 0 0 0 0 0 0 0 0 0 W STD/AP mm 00 00 00 00 00 00 00 00 00 00 H STD/AP mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CRA/K 8-P 0-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of WP versions are specified on technical brochure. Electrical board side 8

FROM 8 KW TO 8 KW. CRA/K/ST 8-P 0-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS, PLATE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. The indoor liquid Chillers and Heat Pumps of the CRA/K/ST 8-P 0-P series, with R0A refrigerant and AQUALOGIK technology, are designed for medium-sized service sector or industrial systems with particular difficulty in positioning units outside the building. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes and are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with radial fans, Scroll compressors and plate-type exchangers even in the version with high ESP fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CRA/K/ST only with AQUALOGIK technology CRA/K/WP/ST Reversible Heat Pump with AQUALOGIK technology CRA/K/AP/ST only with high ESP fans and AQUALOGIK technology CRA/K/WP/AP/ST Reversible Heat Pump with high ESP fans and AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Radial type fans coupled to -phase motors by V belt and variable pulley. Condenser with copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side in 8-P -P models; with two independent circuits on the refrigerant side and one on the water side in -P 0-P models, complete with water differential switch. On the heat pump units it is always installed an antifreeze heater. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit DS Desuperheater RT TX FE SS IS Total heat recovery Coil with pre-coated fins Antifreeze heater for evaporator Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 8

CRA/K/ST 8-P 0-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P (EN) Heating Heating (EN) Available static Electrical characteristics Water circuit Sound capacity () kw..9..9 8. 9.9 0 8 Absorbed power () kw.0 0... 0..8.9..0. EER ().80.9....8..8.. capacity () kw.... 8.9 9.8 0 Absorbed power () kw. 0.8..9... 8.0.8. EER ().0...0..0.8... ESEER.9.0.98.0.0...9.8.8 Heating capacity () kw..8. 80. 90. 0 0 8 Absorbed power () kw 8....8..8..8..8 COP ().9.90.80.89.90.9.8.8..80 Heating capacity () kw..0. 80. 90. 0 0 8 Absorbed power () kw 8...8 8....9 8..0. COP ().9.80.8.8.88.88.80.80.. SCOP ()...0....0.0.0.0 Energy Efficiency () % 8 0 Energy Class () A+ A A A A - - - - - Quantity n Refrigerant circuits n Capacity steps n STD version Pa 0 0 0 90 0 High ESP version Pa 98 88 --- --- 00 --- Power supply V/Ph/Hz 00//0 Max. running current A 8 8 9 9 Max. starting current A 0 9 Water flow l/s...0.8.98.8..0.0 8.9 Pump available static kpa 0 0 0 00 0 0 0 9 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) STD version with SL accessory () db(a) High ESP version () db(a) 8 --- --- 8 --- High ESP version with SL accessory () db(a) --- --- --- Transport weight Kg 80 89 9 98 0 0 0 Operating weight Kg 8 9 0 80 80 90 0 0 90 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P -P 0-P L STD/AP mm 0 0 0 0 0 0 0 0 0 0 W STD/AP mm 00 00 00 00 00 00 00 00 00 00 H STD/AP mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CRA/K/ST 8-P 0-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP versions are specified on technical brochure. Electrical board side 8

FROM 9 KW TO 9 KW. CRA/K 8 0 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS AND SHELL AND TUBE EXCHANGER. The indoor liquid Chillers and Heat Pumps of the CRA/K 8 0 series, with R0A refrigerant, are designed for medium-sized service sector or industrial systems with particular difficulty in positioning units outside the building. They are used, combined with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS8 serial. Equipped with radial fans, Scroll compressors and shell and tube exchanger, even in the version with high ESP fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CRA/K only CRA/K/WP Reversible Heat Pump CRA/K/AP only with high ESP fans CRA/K/WP/AP Reversible Heat Pump with high ESP fans FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Radial type fans coupled to -phase motors by V belt and variable pulley. Condenser with copper tube and aluminium finned coil. Shell and tube type evaporator with one circuit on the refrigerant side and one on the water side in 8 models; with two independent circuits on the refrigerant side and one on the water side in 0 models, complete with water differential switch. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CC Condensing control down to -0 C BT Low water temperature Kit HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU Single circulating pump PD Double circulating pump SPU SPD FE FB SS IS Inertial tank and single circulating pump Inertial tank and double circulating pump Antifreeze heater for evaporator Antifreeze heater for evaporator and tank Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 8

CRA/K 8 0 MODEL 8 0 0 9 0 (EN) Heating Heating (EN) Evaporator Available static Electrical characteristics Unit with tank and pump Sound capacity () kw 9.0.0.. 8. 9. 09 9 9 9 Absorbed power () kw. 0..0.8.0....8. EER ().8..0...9.... capacity () kw 8...0.8 8.9 9. 08 8 8 8 Absorbed power () kw.9 0.. 8.... 8...9 EER ().0....8.0....0 ESEER..0.90.0..0..9.8.8 Heating capacity () kw..9 0. 80. 9. 0 9 88 Absorbed power () kw 8.8.. 8...8. 8... COP ().9.9.80.8.90.9.8.8.8.9 Heating capacity () kw.0. 0. 8. 9.9 0 0 8 89 Absorbed power () kw 9.0..8 9.... 9.. 8.8 COP ().9.8..9.8.90.8.80.. SCOP ()...0.09..9.0..09.09 Energy Efficiency () % 0 Energy Class () A+ A A A A A+ A A A A Quantity n Refrigerant circuits n Capacity steps n Water flow l/s..0.9..98.0..09.0 8. Pressure drops kpa 9 0 0 9 8 Water connections G ½ ½ ½ ½ ½ ½ STD version Pa 0 0 0 90 0 High ESP version Pa 98 88 --- --- 00 --- Power supply V/Ph/Hz 00//0 Max. running current A 8 8 9 90 0 Max. starting current A 9 0 0 0 89 Pump available static kpa 0 0 00 0 0 0 0 Tank water volume l 0 0 0 0 0 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) STD version with SL accessory () db(a) High ESP version () db(a) 8 --- --- 8 --- High ESP version with SL accessory () db(a) --- --- --- Transport weight () Kg 9 8 99 0 08 9 08 Operating weight () Kg 0 0 9 8 80 00 0 0 DIMENSIONS 8 0 0 9 0 L STD/AP mm 0 0 0 0 0 0 0 0 0 0 W STD/AP mm 00 00 00 00 00 00 00 00 00 00 H STD/AP mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CRA/K 8 0 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of WP versions are specified on technical brochure. Electrical board side 8

FROM 9 KW TO 9 KW. CRA/K/ST 8 0 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH RADIAL FANS, SCROLL COMPRESSORS, SHELL AND TUBE EXCHANGER, HYDRONIC KIT AND AQUALOGIK CONTROL SYSTEM. The indoor liquid Chillers and Heat Pumps of the CRA/K/ST 8 0 series, with R0A refrigerant and AQUALOGIK technology, are designed for medium-sized service sector or industrial systems with particular difficulty in positioning units outside the building. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes and are managed by the AQUALOGIK smart control system which optimises the water set point and modulates the power supply voltage of the pump, equipped with Inverter, and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs. Equipped with radial fans, Scroll compressors and shell and tube exchanger, even in the version with high ESP fans, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CRA/K/ST only with AQUALOGIK technology CRA/K/WP/ST Reversible Heat Pump with AQUALOGIK technology CRA/K/AP/ST only with high ESP fans and AQUALOGIK technology CRA/K/WP/AP/ST Reversible Heat Pump with high ESP fans and AQUALOGIK technology FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Radial type fans coupled to -phase motors by V belt and variable pulley. Condenser with copper tube and aluminium finned coil. Shell and tube type evaporator with one circuit on the refrigerant side and one on the water side in 8 models; with two independent circuits on the refrigerant side and one on the water side in 0 models, complete with water differential switch. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a modulating adjustment of the dampers. This device allows also the cooling functioning of the unit by external temperature till -0 C. Water circuit includes: INVERTER circulating pump, safety valve and expansion vessel. Microprocessor control and regulation system with AQUALOGIK technology. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit HR Desuperheater HRT/S Total heat recovery in series HRT/P TX FE SS IS Total heat recovery in parallel Coil with pre-coated fins Antifreeze heater for evaporator Soft start Modbus RTU protocol, RS8 serial LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 88

CRA/K/ST 8 0 MODEL 8 0 0 9 0 (EN) Heating Heating (EN) Available static Electrical characteristics Water circuit Sound capacity () kw 9.0.0.. 8. 9. 09 9 9 9 Absorbed power () kw. 0..0.8.0....8. EER ().8..0...9.... capacity () kw 8...0.8 8.9 9. 08 8 8 8 Absorbed power () kw.9 0.. 8.... 8...9 EER ().0....8.0....0 ESEER..0.90.0..0..9.8.8 Heating capacity () kw..9 0. 80. 9. 0 9 88 Absorbed power () kw 8.8.. 8...8. 8... COP ().9.9.80.8.90.9.8.8.8.9 Heating capacity () kw.0. 0. 8. 9.9 0 0 8 89 Absorbed power () kw 9.0..8 9.... 9.. 8.8 COP ().9.8..9.8.90.8.80.. SCOP ()...0.09..9.0..09.09 Energy Efficiency () % 0 Energy Class () A+ A A A - - - - - - Quantity n Refrigerant circuits n Capacity steps n STD version Pa 0 0 0 90 0 High ESP version Pa 98 88 --- --- 00 --- Power supply V/Ph/Hz 00//0 Max. running current A 8 8 9 9 Max. starting current A 0 9 Water flow l/s..0.9..98.0..09.0 8. Pump available static kpa 0 0 00 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) STD version with SL accessory () db(a) High ESP version () db(a) 8 --- --- 8 --- High ESP version with SL accessory () db(a) --- --- --- Transport weight Kg 90 80 80 00 0 0 0 Operating weight Kg 0 0 80 8 8 00 0 0 DIMENSIONS 8 0 0 9 0 L STD/AP mm 0 0 0 0 0 0 0 0 0 0 W STD/AP mm 00 00 00 00 00 00 00 00 00 00 H STD/AP mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CRA/K/ST 8 0 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of WP versions are specified on technical brochure. Electrical board side 89

FROM 9 KW TO 8 KW. CHA/IK/A -P -P A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, INVERTER SCROLL COMPRESSORS, MICROCHANNEL CONDENSING COILS AND PLATE EXCHANGER. The CHA/IK/A -P -P MULTIPOWER units are characterized by the highest efficiency, all in A CLASS energy efficiency, featuring Microchannel condensing coils and Scroll Inverter compressor: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system. The machine is equipped with R0A refrigerant, guaranteeing full adherence to the protocol standards in the Kyoto Treaty (O.D.P.=0) and providing high energy efficiency. This results in heat loads less than 0% EER surpassing any traditional cooler. In this way, the machine can obtain high energy yield with decisively elevated ESEER/IPLV values, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during the night. The use of components built in large series making them highly reliable and management of an elevated number of compressors allows increased life span and reduction of machine stopping risks: a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSION CHA/IK/A only CHA/IK/A/SSL Super silenced cooling only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. DC INVERTER Scroll and ON-OFF Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of aluminium MICROCHANNEL condensing coils. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valve on liquid line in 00-P -P models. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TXB Coil with epoxy treatment PS Single circulating pump PSI Inverter single circulating pump PD Double circulating pump PDI FE IS ISB ISBT ISL IAV IAA IAS IDL Inverter double circulating pump Antifreeze heater for evaporator Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 90

CHA/IK/A -P -P MODEL -P 8-P 00-P 0-P -P -P -P 0-P -P -P (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 9 8 9 8 8 8 Absorbed power () kw 0 89 9 08 9 09 EER ().......0.0.0.0 capacity () kw 9 8 8 8 Absorbed power () kw 90 98 09 0 EER ().0.9.8..9.8.... ESEER.0.0.0.0..0.8..8. EUROVENT Class A A A A A A A A A A Quantity n + + + + + + + + + + Refrigerant circuits n Capacity steps n Stepless Water flow l/s 9..8..0. 8.0 0..88..9 Pressure drops kpa 8 0 Water connections DN 80 80 80 80 80 0 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 0 0 0 Max. starting current A 0 0 8 8 800 Pump available static kpa 00 0 0 0 9 0 00 Water connections DN 00 00 00 00 00 0 0 0 0 0 STD version () db(a) 8 8 With SL accessory () db(a) 9 9 0 0 SSL version () db(a) --- Transport weight Kg 9 0 80 88 8 9 Operating weight Kg 90 090 0 00 0 80 90 80 80 990 DIMENSIONS -P 8-P 00-P 0-P -P -P -P 0-P -P -P L STD mm 000 000 000 000 000 000 000 00 00 00 SSL mm 000 000 000 00 00 00 00 00 00 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/IK/A -P -P 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 9

FROM KW TO KW. CHA/K/A/WP -P 0-P A CLASS ENERGY EFFICIENCY AIRCOOLED REVERSIBLE HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The CHA/K/A/WP -P 0-P MULTIPOWER reversible Heat Pumps are characterized by the highest efficiency, all in A CLASS energy efficiency. MULTIPOWER is an extremely flexible and reliable machine: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system. The machine is equipped with R0A refrigerant, guaranteeing full adherence to the protocol standards in the Kyoto Treaty (O.D.P.=0) and providing high energy efficiency. The machine can obtain an high energy yield with decisively elevated ESEER/IPLV values, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during the night. The use of components built in large series making them highly reliable and the management of an elevated number of compressors allows increased life span and reduction of machine stopping risks: a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSION CHA/K/A/WP Reversible Heat Pump CHA/K/A/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. On the unit is always installed an antifreeze heater. circuit shut-off valve on liquid line in 08-P 0-P models. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES 9 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins PS Single circulating pump PSI PD PDI SS IS ISB ISBT ISL IAV IAA IAS IDL Inverter single circulating pump Double circulating pump Inverter double circulating pump Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/K/A/WP -P 0-P MODEL -P 8-P 8-P 90-P 08-P 8-P 08-P Heating Heating (EN) (EN) Evaporator Electrical characteristics Unit with pump Sound Heating capacity () kw 9 9 89 Absorbed power () kw 8 8 0 0 COP ()......8. Heating capacity () kw 8 9 0 90 Absorbed power () kw 8 8 8 0 08 COP ()...9.9...9 EUROVENT Class A A A A A A A SCOP ().0..99.08.0..0 Energy Efficiency () % 9 0 8 capacity () kw 9 9 9 9 9 Absorbed power () kw 8 8 8 00 0 EER ().8.89.0.0.9.0.00 capacity () kw 9 8 8 9 8 Absorbed power () kw 9 9 8 0 08 EER ().80.8.0.00.90.9.9 ESEER..9.9.89.9.0.0 EUROVENT Class C C B B C B B Quantity n + + + + + + + Refrigerant circuits n Capacity steps n 8 Water flow l/s 9. 0....0.8.0 Pressure drops kpa 8 9 Water connections DN 80 80 80 80 80 80 80 Power supply V/Ph/Hz 00//0 Max. running current A 8 99 8 Max. starting current A 99 09 Pump available static kpa 9 0 0 0 0 Water connections DN 00 00 00 00 00 00 00 STD version () db(a) 9 8 8 8 9 0 With SL accessory () db(a) SSL version () db(a) 8 0 Transport weight Kg 9 9 09 80 80 Operating weight Kg 90 0 0 0 90 80 80 MODEL 00-P 00-P 8-P 80-P 0-P 0-P Heating Heating (EN) (EN) Evaporator Electrical characteristics Unit with pump Sound Heating capacity () kw 0 Absorbed power () kw 9 0 COP ()..8.9... Heating capacity () kw 8 8 9 Absorbed power () kw 8 0 0 0 COP ().0...0.0. EUROVENT Class A A A A A A SCOP ().0.0.0 - - - Energy Efficiency () % 9 9 9 - - - capacity () kw 9 9 Absorbed power () kw 0 EER ().8.9.9.98.88.8 capacity () kw 8 9 0 9 9 Absorbed power () kw 8 09 EER ().80.8.9.9.8. ESEER.9.9.98.99.9.9 EUROVENT Class C C B B C C Quantity n + + + + + + Refrigerant circuits n Capacity steps n 8 0 Water flow l/s. 0..9. 8..0 Pressure drops kpa 0 Water connections DN 80 80 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 8 9 00 Max. starting current A 0 9 8 8 Pump available static kpa 8 0 90 8 Water connections DN 00 00 00 00 0 0 STD version () db(a) 0 With SL accessory () db(a) 0 0 0 0 SSL version () db(a) --- --- Transport weight Kg 09 0 8 0 98 Operating weight Kg 00 00 0 880 0 0 DIMENSIONS -P 8-P 8-P 90-P 08-P 8-P 08-P 00-P 00-P 8-P 80-P 0-P 0-P L STD mm 800 000 000 000 000 000 000 000 000 00 00 00 00 SSL mm 000 000 000 000 000 000 000 000 00 00 00 --- --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/K/A/WP -P 0-P 00 800 000 800 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Sound power level according to Standard ISO and Eurovent 8/. N.B. of SSL version are specified on technical brochure. Electrical board side 9

FROM 99 KW TO 0 KW. CHA/K -P 0-P AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. CHA/K -P 0-P MULTIPOWER is an extremely flexible and reliable machine: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system. The machine is equipped with R0A refrigerant, guaranteeing full adherence to the protocol standards in the Kyoto Treaty (O.D.P.=0), and features high energy yield, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during the night. The use of components built in large series, making them highly reliable, and the management of an elevated number of compressors allows increased life span and reduction of machine stopping risks: a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSION CHA/K only CHA/K/WP Reversible Heat Pump CHA/K/SSL Super silenced cooling only CHA/K/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. On Heat Pump units is always installed an antifreeze heater. circuit shut-off valve on liquid line in 08-P 0-P models. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans DS Desuperheater RT Total heat recovery TX Coil with pre-coated fins PS Single circulating pump PSI Inverter single circulating pump PD Double circulating pump PDI FE SS IS ISB ISBT ISL IAV IAA IAS IDL Inverter double circulating pump Antifreeze heater for evaporator Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 9

CHA/K -P 0-P MODEL -P 8-P 8-P 90-P 08-P 8-P 08-P 00-P 00-P (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 99 0 0 Absorbed power () kw 9 80 8 9 0 EER ().88.8.9.9.9.9.0.0.8 capacity () kw 98 0 0 0 Absorbed power () kw 0 8 8 9 0 EER ().8.8.89.89.8.9.9.00.8 ESEER......88..90. Heating capacity () kw 8 8 0 8 9 0 0 Absorbed power () kw 8 90 0 08 COP ()..0..0..0.0.. Heating capacity () kw 8 8 8 0 0 Absorbed power () kw. 8. 90. 0 08 COP ()..0..0..0.0..0 SCOP ().9..8.....9. Energy Efficiency () % 9 9 Quantity n + + + + + + + + + Refrigerant circuits n Capacity steps n 8 Water flow l/s 9. 0.80.99.9..0. 9.. Pressure drops kpa 0 0 9 9 9 Water connections DN 80 80 80 80 80 80 80 80 80 Power supply V/Ph/Hz 00//0 Max. running current A 9 9 0 Max. starting current A 99 9 9 0 8 0 8 Pump available static kpa 99 8 0 9 Water connections DN 00 00 00 00 00 00 00 00 00 STD version () db(a) 9 9 0 8 9 With SL accessory () db(a) SSL version () db(a) 9 8 0 9 Transport weight Kg 9 99 0 9 Operating weight Kg 0 90 80 980 0 80 90 0 0 MODEL 8-P 80-P 0-P 0-P 0-P 00-P 0-P 0-P (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 9 0 8 9 0 Absorbed power () kw 0 8 0 EER ().9.9.8...9.80.88 capacity () kw 9 99 9 9 8 99 0 Absorbed power () kw 8 0 9 9 EER ().8.9.8..0...8 ESEER......9..8 Heating capacity () kw 0 8 8 9 08 0 Absorbed power () kw 8 0 9 8 9 8 COP ().0.0.0..0.08.09. Heating capacity () kw 8 8 9 09 Absorbed power () kw 8 0 0 8 0 8 COP ().09.0.0..0.08.08. SCOP () - - - - - - - - Energy Efficiency () % - - - - - - - - Quantity n + + + + + + + + Refrigerant circuits n Capacity steps n 0 Water flow l/s..09 8..0.88 0..0 0. Pressure drops kpa 9 0 8 9 Water connections DN 80 80 80 0 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 0 8 98 Max. starting current A 8 00 9 8 98 00 Pump available static kpa 9 8 Water connections DN 00 00 0 0 0 0 0 0 STD version () db(a) 8 0 With SL accessory () db(a) 9 0 0 0 0 SSL version () db(a) 0 --- --- Transport weight Kg 9 8 00 8 98 0 Operating weight Kg 0 00 0 0 0 80 8 DIMENSIONS -P 8-P 8-P 90-P 08-P 8-P 08-P 00-P 00-P 8-P 80-P 0-P 0-P 0-P 00-P 0-P 0-P L STD mm 800 800 800 800 000 000 000 000 000 000 000 000 000 00 00 00 00 SSL mm 800 800 800 800 000 000 000 000 000 000 000 000 00 00 00 --- --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/K -P 0-P 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side 9

FROM 08 KW TO 0 KW. CHA/K/FC -P 0-P AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGER. The liquid Chillers of the CHA/K/FC -P 0-P series, with R0A refrigerant, provide advanced technology, flexible and reliable, through an intelligent control module which optimizes the operating times and the powers delivered by the Scroll compressors, according to the needs of the systems, both civil and industrial, where the production of chilled water is required in continuous service throughout the year. During the cold months, in FREE-COOLING operating mode, the liquid returning from the system is cooled directly, by way of the forced convection of outside air through the condensing coil, thus reducing the energy required for the Scroll compressors operation that the units are equipped with. A system of -way valves, controlled by the electronic microprocessor controller that manages the entire unit, can, depending on outside air temperature, operate in the CHILLER, FREE-COOLING or MIXED (CHILLER and FREE-COOLING at the same time) mode. CHA/K/FC -P 0-P allows the reduction of inrush currents generated, the elimination of inertial accumulation tanks and an excellent silent functioning, as the fans adjust their speed to the actual load of the system, providing great benefits especially at night. VERSION CHA/K/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valve on liquid line in 08-P 0-P models. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans TX Coil with pre-coated fins PS Single circulating pump PSI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump SS IS ISB ISBT ISL IAV IAA IAS IDL Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 9

CHA/K/FC -P 0-P MODEL -P 8-P 8-P 90-P 08-P 8-P 08-P 00-P 00-P Free- cycle Water circuit Electrical characteristics Unit with pump Sound capacity () kw 08 90 8 0 8 Absorbed power () kw 8 88 98 08 EER ()...99.9.0.9.0.00.9 Air temperature () C -.0 -.8 -. -0. -. -. -.0 -.0 -.0 Absorbed power () kw.0.0 0. 0..0.0.0.0. Quantity n + + + + + + + + + Refrigerant circuits n Capacity steps n Water flow l/s.0.8.8.. 9.... Pressure drops kpa 0 0 00 0 Water connections DN 00 00 00 00 00 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 8 99 9 8 Max. starting current A 99 00 Pump available static kpa 0 0 0 0 Water connections DN 00 00 00 00 00 00 00 00 00 STD version () db(a) 8 9 9 0 0 0 With SL accessory () db(a) Transport weight Kg 8 0 990 00 0 0 90 Operating weight Kg 0 0 00 0 90 0 0 0 0 MODEL 8-P 80-P 0-P 0-P 0-P 00-P 0-P 0-P Free- cycle Water circuit Electrical characteristics Unit with pump Sound capacity () kw 90 8 8 90 0 0 Absorbed power () kw 9 99 0 0 0 8 EER ().99.9.89..... Air temperature () C -. -. -.0 -. -. -0. 0. -0. Absorbed power () kw....0. 8.0.. Quantity n + + + + + + + + Refrigerant circuits n Capacity steps n 8 Water flow l/s 8.8.09. 8.89. 8.. 8. Pressure drops kpa 8 Water connections DN 0 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 8 00 99 9 Max. starting current A 8 8 8 9 0 Pump available static kpa 0 80 0 0 00 Water connections DN 0 0 0 0 0 STD version () db(a) With SL accessory () db(a) 8 0 Transport weight Kg 80 0 00 0 80 880 0 0 Operating weight Kg 0 0 0 0 0 00 80 80 DIMENSIONS -P 8-P 8-P 90-P 08-P 8-P 08-P 00-P 00-P 8-P 80-P 0-P 0-P 0-P 00-P 0-P 0-P L STD mm 000 000 000 000 000 000 000 000 00 00 00 00 00 800 900 000 000 W STD mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD mm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CLEARANCE AREA CHA/K/FC -P 0-P 00 800 000 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at which the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO. Electrical board side 9

FROM 00 KW TO 0 KW. CHA/K 0 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCROLL COMPRESSORS AND SHELL AND TUBE EXCHANGER. CHA/K 0 is an extremely flexible and reliable machine: an intelligent control module optimizes functioning times and supplied power from the Scroll compressors based on heat load demands in the system. The machine is equipped with R0A refrigerant, guaranteeing full adherence to the protocol standards in the Kyoto Treaty (O.D.P.=0), and features high energy yield, elimination of generated power surges, elimination of inertial accumulation tanks and excellent silent functioning, since the fans adjust their speeds to the actual system load, providing benefits especially during the night. The use of components built in large series, making them highly reliable, and the management of an elevated number of compressors allows increased life span and reduction of machine stopping risks: a faulty compressor will not compromise cooler functioning, which will continue to function with decreased power levels. In addition, maintenance operations are decisively reduced due to the high reliability of the machines and their components. VERSION CHA/K only CHA/K/WP Reversible Heat Pump CHA/K/SSL Super silenced cooling only CHA/K/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valve on liquid line in 08 0 models. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins PU Single circulating pump PUI Inverter single circulating pump PD Double circulating pump PDI FE SS IS ISB ISBT ISL IAV IAA IAS IDL Inverter double circulating pump Antifreeze heater for evaporator Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 98

CHA/K 0 MODEL 8 8 90 08 8 08 00 00 (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 00 8 0 0 8 0 Absorbed power () kw 0 80 8 9 0 8 EER ().8.80.88.8.88.8.0.9.8 capacity () kw 99 9 0 0 Absorbed power () kw 8 8 98 0 9 EER ().80..8..8.9.9.9.9 ESEER..9.0....80.8.8 Heating capacity () kw 9 80 0 0 Absorbed power () kw 8 9 0 09 0 COP ().09.0.08.8.08.9.08.0.0 Heating capacity () kw 9 80 0 0 Absorbed power () kw. 8. 9. 0 09 8 COP ().08.0.0.8.0.9.0.0.0 SCOP ().9......9.0. Energy Efficiency () % 9 Quantity n + + + + + + + + + Refrigerant circuits n Capacity steps n 8 Water flow l/s 9. 0.8....9. 9.08.0 Pressure drops kpa 0 8 Water connections DN 00 00 00 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 9 9 0 Max. starting current A 99 9 9 0 8 0 8 Pump available static kpa 9 0 0 0 00 90 0 Water connections DN 00 00 00 00 00 00 00 00 00 STD version () db(a) 9 9 0 8 9 With SL accessory () db(a) SSL version () db(a) 9 8 0 9 Transport weight Kg 0 8 00 9 8 Operating weight Kg 0 0 80 00 0 00 0 80 80 MODEL 8 80 0 0 0 00 0 0 (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 0 8 8 9 0 Absorbed power () kw 8 0 8 0 0 9 EER ().9.9.8...8.8.88 capacity () kw 08 9 8 88 98 08 Absorbed power () kw 88 8 EER ().89.9.8..9..9.8 ESEER.8..9..0...80 Heating capacity () kw 8 98 9 88 98 00 Absorbed power () kw 8 0 88 88 COP ()..0.09.08.0.0.. Heating capacity () kw 8 99 9 89 98 0 Absorbed power () kw 8 0 8 89 89 COP ()..0.08.0.0.0.. SCOP () - - - - - - - - Energy Efficiency () % - - - - - - - - Quantity n + + + + + + + + Refrigerant circuits n Capacity steps n 0 Water flow l/s.08.0 8.99.0. 0..8 0. Pressure drops kpa 9 Water connections DN 0 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 0 8 98 Max. starting current A 8 00 9 8 98 00 Pump available static kpa 9 9 0 0 Water connections DN 00 00 0 0 0 0 0 0 STD version () db(a) 8 0 With SL accessory () db(a) 9 0 0 0 0 SSL version () db(a) 0 --- --- Transport weight Kg 8 0 80 8 0 0 0 Operating weight Kg 80 0 0 90 0 80 0 90 DIMENSIONS 8 8 90 08 8 08 00 00 8 80 0 0 0 00 0 0 L STD mm 800 800 800 800 000 000 000 000 000 000 000 000 000 00 00 00 00 SSL mm 800 800 800 800 000 000 000 000 000 000 000 000 00 00 00 --- --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/K 0 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure. Electrical board side 99

FROM 9 KW TO 90 KW. CHA/K/EP 8-P 9-P AIRCOOLED -PIPE MULTIFUNCTIONAL UNITS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. ENERGYPOWER is the range of multifunctional units for -Pipe systems with high efficiency. The units CHA/K/EP 8-P 9-P feature R0A refrigerant and Scroll compressors activated in series based on the requested thermal load, to reach high EER and ESEER/ IPLV energy values. Thanks to the advanced control system, the units can simultaneously fulfill the heating, cooling and domestic hot water request of the building. The unit can manage the opposed thermal loads at the same time and reach the highest possible efficiency. ENERGYPOWER units make the traditional layout of the technical plants easier because the production of thermal energy for the several users are joint in one unit only; the result is an advantage in terms of installation, maintenance and management and in the meantime of the comfort needs. As option also with EC Inverter axial fans. VERSION CHA/K/EP Multifunctional unit CHA/K/EP/SSL Super silenced Multifunctional unit FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Two copper tube and aluminum finned coils. Condenser AISI stainless steel braze welded plates type, with one circuit on the refrigerant side and one on the water side. On the unit is always installed an antifreeze heater. Evaporator AISI stainless steel braze welded plate type with one circuit on the refrigerant side and one on the water side, complete with water differential switch. On the unit is always installed an antifreeze heater. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES 00 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans TX Coil with pre-coated fins PS Single circulating pump PSI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump PSH Single circulating pump heating side PSIH Inverter single circulating pump heating side PDH Double circulating pump heating side PDIH FG FM SS TS WM IS ISB ISBT ISL IAV IAA IAS IDL Inverter double circulating pump heating side Antifreeze heater for single pump and pipes Antifreeze heater for double pump and pipes Soft start Touch screen Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers

CHA/K/EP 8-P 9-P MODEL 8-P 0-P -P -P 0-P -P 9-P -P 0-P 0-P 9-P only Heating only + Heating Evaporator - cooling side Condenser - heating side Electrical characteristics Unit with pump cooling side Unit with pump heating side Sound capacity () kw 8..9.. 8.8 9. 0 8 9 90 Absorbed power () kw.8 9..9..9. 8.0... 8. EER ().89.90.89.9.9.8..9.88.. Heating capacity () kw. 9..0. 8.0 98. 0 Absorbed power () kw.0 8.... 0.0. 9..8.. COP ()..9....8..... capacity () kw 9...9.8 8. 9.0 0 0 8 0 Heating capacity () kw.9.9 8. 9. 09 8 Absorbed power () kw.. 9... 9... 0. 9.0 8. TER ().8.9....8...89.8.9 Quantity n Refrigerant circuits n Capacity steps n Water flow l/s...0..9..0..0.0 9.08 Pressure drops kpa 0 9 8 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ Water flow () l/s.9.8.0...0.0.0.8 8. 9.0 Pressure drops () kpa 8 0 8 Water connections () G ½ ½ ½ ½ ½ ½ ½ ½ ½ Power supply V/Ph/Hz 00//0 Max. running current A 0 9 8 9 00 8 Max. starting current A 8 9 0 0 9 Pump available static kpa 0 0 0 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ Pump available static kpa 0 0 0 0 Water connections G ½ ½ ½ ½ ½ ½ ½ ½ ½ STD version () db(a) 0 9 0 0 With SL accessory () db(a) 8 0 0 8 8 SSL version () db(a) 8 8 8 0 0 Transport weight Kg 0 0 8 90 9 00 0 08 9 00 Operating weight Kg 80 9 90 00 08 9 DIMENSIONS 8-P 0-P -P -P 0-P -P 9-P -P 0-P 0-P 9-P L STD mm 0 0 0 0 0 0 0 0 0 0 0 SSL mm 0 0 0 0 0 0 0 0 0 00 00 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 90 90 90 0 0 0 0 0 0 0 0 CLEARANCE AREA CHA/K/EP 8-P 9-P 00 800 800 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Chilled water from to C, heated water from 0 to C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 0

FROM KW TO KW. CHA/K/EP 0-P 0-P AIRCOOLED -PIPE MULTIFUNCTIONAL UNITS WITH AXIAL FANS, SCROLL COMPRESSORS AND PLATE EXCHANGERS. ENERGYPOWER is the range of multifunctional units for -Pipe systems with high efficiency. The units CHA/K/EP 8-P 9-P feature R0A refrigerant and Scroll compressors activated in series based on the requested thermal load, to reach high EER and ESEER/ IPLV energy values. The units are characterized by double cooling circuit. Thanks to the advanced control system, ENERGYPOWER units can simultaneously fulfill the heating, cooling and domestic hot water request of the building. The unit can manage the opposed thermal loads at the same time and reach the highest possible efficiency. ENERGYPOWER units make the traditional layout of the technical plants easier because the production of thermal energy for the several users are joint in one unit only; the result is an advantage in terms of installation, maintenance and management and in the meantime of the comfort needs. As option also with EC Inverter axial fans. VERSION CHA/K/EP Multifunctional unit CHA/K/EP/SSL Super silenced Multifunctional unit FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Scroll compressors with oil sight glass, internal overheat protection and crankcase heater. Axial fans directly coupled to an electric motor with external rotor. Two copper tube and aluminum finned coils. Condenser AISI stainless steel braze welded plates type, with two independent circuits on the refrigerant side and one on the water side. On the unit is always installed an antifreeze heater. Evaporator AISI stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. On the unit is always installed an antifreeze heater. Electronic thermostatic valve. Digital high and low gauges. R0A refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RFM circuit shut-off valve on discharge line RFL circuit shut-off valve on liquid line BT Low water temperature Kit EC EC Inverter fans TX Coil with pre-coated fins PS Single circulating pump PSI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump PSH Single circulating pump heating side PSIH Inverter single circulating pump heating side PDH Double circulating pump heating side PDIH Inverter double circulating pump heating side FG FM SS TS WM IS ISB ISBT ISL IAV IAA IAS IDL Antifreeze heater for single pump and pipes Antifreeze heater for double pump and pipes Soft start Touch screen Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers 0

CHA/K/EP 0-P 0-P MODEL only Heating only + Heating Evaporator - cooling side Condenser - heating side Electrical characteristics Unit with pump cooling side Unit with pump heating side Sound 0-P -P 80-P 90-P 00-P 0-P 0-P0-P80-P00-P0-P0-P capacity () kw 90 0 9 9 9 8 Absorbed power () kw 9 8 9 0 0 9 9 0 EER ().9..88.8.8.89.9.8..0.8.8 Heating capacity () kw 80 0 8 8 0 9 Absorbed power () kw 9 8 9 09 8 9 8 9 08 COP ()..0...8.8....9.. capacity () kw 0 9 0 0 0 9 Heating capacity () kw 0 8 8 9 89 Absorbed power () kw 0 0 8 9 0 8 9 8 9 TER ().80.0.9.8.....8..9. Quantity n Refrigerant circuits n Capacity steps n Water flow l/s.98 9.08 0....8.0 8.8.9.9.8 0. Pressure drops kpa 0 Water connections DN 00 00 00 00 00 00 00 00 0 0 0 Water flow () l/s 8.0 9..0.8..9. 0.0.. 0.0. Pressure drops () kpa 9 0 9 8 Water connections () DN 00 00 00 00 00 00 00 00 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 8 0 0 8 8 Max. starting current A 0 8 00 88 9 8 Pump available static kpa 0 0 0 00 0 0 0 Water connections DN 00 00 00 00 00 00 00 00 0 0 0 Pump available static kpa 0 0 0 0 0 0 0 Water connections DN 00 00 00 00 00 00 00 00 0 0 0 STD version () db(a) 0 0 8 9 With SL accessory () db(a) 8 8 9 9 9 0 SSL version () db(a) 0 0 Transport weight Kg 00 0 0 90 0 80 0 0 0 00 0 0 Operating weight Kg 00 0 0 00 0 0 0 80 0 80 0 0 DIMENSIONS 0-P -P 80-P 90-P 00-P 0-P 0-P 0-P 80-P 00-P 0-P 0-P L STD mm 0 0 0 0 0 000 000 000 00 00 00 00 SSL mm 0 0 0 000 000 000 00 00 00 00 00 00 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 H STD/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/K/EP 0-P 0-P 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Chilled water from to C, heated water from 0 to C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 0

FROM 8 KW TO KW. CHA/IY/EP 0 AIRCOOLED -PIPE MULTIFUNCTIONAL UNITS WITH AXIAL FANS, INVERTER SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGERS. ENERGYPOWER is the range of multifunctional units for -Pipe systems with high efficiency. The units CHA/IY/EP 0 ENERGYPOWER, with Ra refrigerant, are provided with the new technological Inverter mono-screw compressors with satellite, the units reach high EER and ESEER/IPLV energy values. Thanks to the advanced control system, the units can simultaneously fulfill the heating, cooling and domestic hot water request of the building. The unit can manage the opposed thermal loads at the same time and reach the highest possible efficiency. ENERGYPOWER units make the traditional layout of the technical plants easier because the production of thermal energy for the several users are joint in one unit only; the result is an advantage in terms of installation, maintenance and management and in the meantime of the comfort needs. As option also with EC Inverter axial fans. VERSION CHA/IY/EP Multifunctional unit CHA/IY/EP/SSL Super silenced Multifunctional unit FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. INVERTER and ON/OFF Screw compressors, with built-in oil separator, suction filter, cranckcase heater, oil sight glass, thermal protection and stepless capacity steps. Axial fans directly coupled to an electric motor with external rotor. Two copper tube and aluminum finned coils. Shell and tube type condenser, with two independent circuits on the refrigerant side and one on the water side. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till 0 C. Microprocessor control and regulation system. ACCESSORIES 0 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans TX Coil with pre-coated fins PUI Inverter single circulating pump PDI Inverter double circulating pump FI Antifreeze heater for evaporator and condenser FG Antifreeze heater for single pump and pipes FM Antifreeze heater for double pump and pipes SS TS WM IS ISB ISBT ISL IAV IAA IAS IDL CP Soft start Touch screen Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/IY/EP 0 MODEL 0 0 80 9 0 0 0 90 0 only Heating only + Heating Evaporator - cooling side Condenser - heating side Electrical characteristics Unit with pump Sound capacity () kw 8 8 8 98 Absorbed power () kw 89 00 0 8 EER ()....8..9..9.0.0 Heating capacity () kw 8 0 90 88 990 Absorbed power () kw 8 9 0 9 9 90 COP ().9..0...0....9 capacity () kw 8 0 9 9 8 8 99 8 Heating capacity () kw 9 0 9 8 0 9 Absorbed power () kw 8 8 99 0 9 0 TER (). 8.0 8. 8. 8. 8. 8. 8.8 8. 8. Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s.8.9.9 0...9.0 9... Pressure drops kpa 8 8 8 Water connections DN 00 00 0 0 0 0 00 Water flow () l/s. 9.0..99 9..9. 0. 0.. Pressure drops () kpa 9 8 9 Water connections () DN 00 00 0 0 0 0 00 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 09 9 80 0 Max. starting current A 8 8 9 0 8 8 8 Pump available static kpa 80 90 0 80 0 0 0 0 0 Water connections DN 00 00 0 0 0 0 00 STD version () db(a) 8 8 8 9 80 80 8 With SL accessory () db(a) SSL version () db(a) 8 9 9 0 0 Transport weight Kg 090 0 80 0 90 90 800 90 90 00 Operating weight Kg 0 0 80 980 80 0 8880 000 00 800 DIMENSIONS 0 0 80 9 0 0 0 90 0 STD mm 0 0 00 0 8900 8900 000 00 00 00 L SSL mm 00 00 0 0 8900 000 00 0 0 0 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 STD mm 00 00 00 00 00 00 00 00 00 00 H SSL mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/IY/EP 0 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Chilled water from to C, heated water from 0 to C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 0

FROM 8 KW TO 8 KW. CHA/IY/WP 0 A CLASS ENERGY EFFICIENCY REVERSIBLE HEAT PUMPS WITH AXIAL FANS, INVERTER SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGER. The aircooled reversibile Heat Pump units of the line CHA/IY/WP 0, in A CLASS and with Ra refrigerant, are suitable for big sizes installations, such as commercial or industrial buildings. The units are provided with the new technological Inverter mono-screw compressors with satellite, axial fans and shell and tube evaporator and are available also with super low noise version; as option also with EC Inverter axial fans and with Inverter regulated circulating pumps. The designed large condensing coils, the high efficiency fans, the optimisation of the water and cooling circuits, the Inverter Screw compressors, allow the units to reach the A CLASS energy efficiency, if combined with a proper sizing of the end-user plant. VERSION CHA/IY/WP Reversible Heat Pump CHA/IY/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. INVERTER Screw compressors, with built-in oil separator, suction filter, cranckcase heater, oil sight glass, thermal protection and stepless capacity steps. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till 0 C. Microprocessor control and regulation system. ACCESSORIES 0 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series TX Coil with pre-coated fins PUI Inverter single circulating pump PDI Inverter double circulating pump FE Antifreeze heater for evaporator FZ Antifreeze heater for evaporator, single pump and pipes FH Antifreeze heater for evaporator, double pump and pipes SS WM IS ISB ISBT ISL IAV IAA IAS IDL CP Soft start Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/IY/WP 0 MODEL 0 0 80 9 0 0 0 90 0 Heating Heating (EN) (EN) Evaporator Electrical characteristics Unit with pump Sound Heating capacity () kw 8 8 0 8 000 8 Absorbed power () kw 88 9 0 9 0 COP ().0..8.0..8....9 Heating capacity () kw 8 0 80 00 Absorbed power () kw 90 9 9 8 0 8 COP ()...0...0.... EUROVENT Class A A A A A A A A A A SCOP ().....0. - - - - Energy Efficiency () % 8 9 - - - - capacity () kw 8 8 8 98 Absorbed power () kw 89 00 0 8 EER ()....8..9..9.0.0 capacity () kw 8 89 9 8 Absorbed power () kw 90 0 8 9 9 0 EER ().08.0.0......0.0 ESEER..9...9.90.0.9.9.0 EUROVENT Class B B B A A A A A B B Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s.8.9.9 0...9.0 9... Pressure drops kpa 8 8 8 Water connections DN 0 0 0 00 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 09 9 80 0 Max. starting current A 8 8 9 0 8 8 8 Pump available static kpa 80 90 0 80 0 0 0 0 0 Water connections DN 00 00 0 0 0 0 00 STD version () db(a) 8 8 8 9 80 80 8 With SL accessory () db(a) SSL version () db(a) 8 9 9 0 0 Transport weight Kg 80 800 0 90 80 0 0 80 8 90 Operating weight Kg 90 90 90 0 0 0 80 8990 90 00 DIMENSIONS 0 0 80 9 0 0 0 90 0 STD mm 0 0 00 0 8900 8900 000 00 00 00 L SSL mm 00 00 0 0 8900 000 00 0 0 0 W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 STD mm 00 00 00 00 00 00 00 00 00 00 H SSL mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/IY/WP 0 00 800 000 800 NOTES. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL version are specified on technical brochure. Electrical board side 0

FROM KW TO KW. CHA/Y/A 0 80 A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, (INVERTER) SCREW COMPRESSORS, MICROCHANNEL CONDENSING COILS AND SHELL AND TUBE EXCHANGER. The CHA/Y/A 0 80 units in A CLASS energy efficiency have EER values higher than. due to reduced electrical absorption and a high efficiency of the compressor-exchanger combination. The Microchannel condensing coils, the mono-screw compressors with satellite and the new design optimized in every detail ensure the reach of the highest efficiency. Furthermore, accessories as the Inverter control on Screw compressors, on circulating pumps and EC Inverter on fans are also available for getting the highest efficiency at part load. The super silenced version, obtained through acoustic insulation on compressors and wider exchangers, is particularly suitable for installations where extremely quiet operation are essential for the ideal execution of the system. The Inverter accessory is equipped with SYNCHRONIZER that allows you to extend the useful life of the compressor, ensuring the rotation at every boot, and significantly reduce the inrush current of the unit. VERSION CHA/Y/A only CHA/Y/A/SSL Super silenced cooling only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Screw compressors with built-in oil separator, suction filter, cranckcase heater, oil sight glass, thermal protection and stepless capacity steps. Axial fans directly coupled to an electric motor with external rotor. Condenser made of aluminium MICROCHANNEL condensing coils. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till 0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TXB Coil with epoxy treatment SP Inertial tank PU Single circulating pump PUI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump SPU Inertial tank and single circulating pump SPUI Inertial tank and Inverter single circulating pump SPD Inertial tank and double circulating pump SPDI FE FB FZ FH FU FD II SS WM IS Inertial tank and Inverter double circulating pump Antifreeze heater for evaporator Antifreeze heater for evaporator and tank Antifreeze heater for evaporator, single pump and pipes Antifreeze heater for evaporator, double pump and pipes Antifreeze heater for evaporator, tank, single pump and pipes Antifreeze heater for evaporator, tank, double pump and pipes Inverter on one compressor and Synchronizer Soft start Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial ISB BACnet MSTP protocol, RS8 serial ISBT BACnet TCP/IP protocol, Ethernet port ISL LonWorks protocol, FFT-0 serial IAV Remote set-point, 0-0 V signal IAA Remote set-point, -0 ma signal IAS Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 08

CHA/Y/A 0 80 MODEL 0 0 0 90 00 0 00 0 0 80 (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 9 9 89 99 Absorbed power () kw 80 9 8 99 EER ().9.....8....9 capacity () kw 8 9 8 9 Absorbed power () kw 8 9 9 0 9 EER ()..8..9...0... ESEER.9.0.9.0.0.0.9.0.0.0 EUROVENT Class A A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s..9. 9.... 0.09.8.8 Pressure drops kpa 0 9 8 9 8 Water connections DN 0 0 0 0 0 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 0 0 9 8 80 0 Max. starting current A 8 0 0 9 8 8 8 Pump available static kpa 8 00 0 8 0 8 0 0 Tank water volume l 000 000 000 000 000 000 000 000 --- --- Water connections DN 00 00 00 0 0 0 00 00 STD version () db(a) 8 With SL accessory () db(a) SSL version () db(a) 8 8 --- Transport weight () Kg 8 89 8 0 0 80 8 0 Operating weight () Kg 8 0 90 890 90 0 0 90 0 90 DIMENSIONS 0 0 0 90 00 0 00 0 0 80 STD mm 00 00 000 0 00 00 8900 00 00 00 L SSL mm 0 0 0 00 8900 8900 00 00 00 --- W STD/SSL mm 00 00 00 00 00 00 00 00 00 00 STD mm 00 00 00 00 00 00 00 00 00 00 H SSL mm 00 00 00 00 00 00 00 00 00 --- CLEARANCE AREA CHA/Y/A 0 80 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. N.B. of SSL version are specified on technical brochure. Electrical board side 09

FROM KW TO 9 KW. CHA/Y 0-B 80-B AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGER. CHA/Y 0-B 80-B series liquid Chillers and Heat Pumps, with Ra refrigerant, are designed for large service sector or industrial-type ambients. They are used, together with terminal units, for air conditioning of rooms, or to remove the heat created during industrial processes. Equipped with axial fans, Screw compressors and shell and tube exchanger, even in the super silent version, they can be completed with a hydraulic circuit with tank, pump, or tank and pump. The use of large condensing coils and high unit efficiency fans, as well as optimisation of the hydraulic and refrigerant circuit and the use of latest-generation Screw compressors, combined with a adequate sizing of the user system, ensure high operating efficiency with a considerably reduction in energy consumption. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA/Y only CHA/Y/WP Reversible Heat Pump CHA/Y/SSL Super silenced cooling only CHA/Y/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Screw compressors with built-in oil separator, suction filter, cranckcase heater, oil sight glass, thermal protection and stepless capacity steps. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a step regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till 0 C. Microprocessor control and regulation system. ACCESSORIES 0 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement CC Condensing control down to -0 C BT Low water temperature Kit EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU Single circulating pump PUI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump SPU Inertial tank and single circulating pump SPUI Inertial tank and Inverter single circulating pump SPD SPDI FE FB FZ FH FU FD SS WM IS Inertial tank and double circulating pump Inertial tank and Inverter double circulating pump Antifreeze heater for evaporator Antifreeze heater for evaporator and tank Antifreeze heater for evaporator, single pump and pipes Antifreeze heater for evaporator, double pump and pipes Antifreeze heater for evaporator, tank, single pump and pipes Antifreeze heater for evaporator, tank, double pump and pipes Soft start Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial ISB BACnet MSTP protocol, RS8 serial ISBT BACnet TCP/IP protocol, Ethernet port ISL LonWorks protocol, FFT-0 serial IAV Remote set-point, 0-0 V signal IAA Remote set-point, -0 ma signal IAS Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/Y 0-B 80-B MODEL 0-B 0-B 0-B 0-B 90-B 00-B 0-B 00-B (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 0 8 9 9 8 Absorbed power () kw 80 88 9 EER ()..98.0....9.9 capacity () kw 0 0 9 8 Absorbed power () kw 8 89 9 8 8 99 EER ()..9..0.8.8..9 ESEER....8..9.8.0 Heating capacity () kw 89 8 90 Absorbed power () kw 8 9 0 0 8 0 9 COP ().00..8..... Heating capacity () kw 89 8 90 Absorbed power () kw 8 9 0 9 COP ().00..8.9..0..8 SCOP ().0...8.0.99..9 Energy Efficiency () % 0 9 Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s 0.... 8.8...8 Pressure drops kpa 0 9 8 0 Water connections DN 00 00 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 9 0 8 Max. starting current A 0 89 88 0 Pump available static kpa 0 0 0 9 9 0 Tank water volume l 00 00 00 00 00 000 000 000 Water connections DN 00 00 00 00 0 0 STD version () db(a) With SL accessory () db(a) SSL version () db(a) 8 Transport weight Kg 0 0 80 90 0 800 00 0 Operating weight Kg 0 80 90 00 0 90 0 00 MODEL 0-B 0-B 80-B 0-B 00-B 0-B 80-B (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 80 9 089 8 9 Absorbed power () kw 8 0 9 EER ().8.8....8.88 capacity () kw 80 90 08 9 89 Absorbed power () kw 8 8 0 8 99 EER ().80.8...9..8 ESEER...9.9..8. Heating capacity () kw 80 0 0 8 --- Absorbed power () kw 0 8 0 9 8 --- COP ()...8... --- Heating capacity () kw 0 8 08 --- Absorbed power () kw 8 0 0 --- COP ()...0... --- SCOP () - - - - - - --- Energy Efficiency () % - - - - - - --- Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s 8..8.0 8.9. 0..0 Pressure drops kpa 0 8 Water connections DN 00 00 00 00 00 00 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 0 8 89 9 Max. starting current A 80 80 80 Pump available static kpa 0 0 0 00 80 0 Tank water volume l 000 000 --- --- --- --- --- Water connections DN 0 00 00 00 00 00 00 STD version () db(a) 8 8 9 9 80 80 With SL accessory () db(a) SSL version () db(a) 9 9 0 0 0 0 --- Transport weight Kg 80 0 80 880 000 Operating weight Kg 0 00 0 80 800 980 00 DIMENSIONS 0-B 0-B 0-B 0-B 90-B 00-B 0-B 00-B 0-B 0-B 80-B 0-B 00-B 0-B 80-B STD mm 0 0 0 0 00 0 0 00 00 0 000 000 000 00 00 L SSL mm 0 0 0 00 00 0 00 0 0 000 000 00 00 00 --- WP mm 00 00 00 00 0 00 00 0 0 8900 0 0 00 00 --- WP/SSL mm 00 00 00 0 0 00 00 0 8900 00 00 00 --- --- --- W * STD/WP mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 --- WP/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 --- --- --- CLEARANCE AREA NOTES CHA/Y 0-B 80-B 00 800 000 800 Electrical board side. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Seasonal energy efficiency of ambient heating at low temperature with average climatic conditions. According to EU Regulation n. 8/0.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. of SSL and WP versions are specified on technical brochure. * STD-SSL-WP-WP/SSL

FROM KW TO 0 KW. CHA/Y/FC 0-B 00-B AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGER. The liquid Chillers of the CHA/Y/FC 0-B 00-B series, with Ra refrigerant, offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round. During the cold months, in FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensing coil, thus saving energy by not operating the unit s Screw compressors. A -way valve system is controlled by the electronic microprocessor controller, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE-COOLING) modes. VERSION CHA/Y/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Screw compressors with built-in oil separator, suction filter, cranckcase heater, oil sight glass, thermal protection and stepless capacity steps. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement BT Low water temperature Kit EC EC Inverter fans HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU Single circulating pump PUI Inverter single circulating pump PD Double circulating pump PDI Inverter double circulating pump SPU Inertial tank and single circulating pump SPUI Inertial tank and Inverter single circulating pump SPD Inertial tank and double circulating pump SPDI SS WM IS ISB ISBT ISL IAV IAA IAS Inertial tank and Inverter double circulating pump Soft start Web Monitoring - Wireless remote monitoring (GPRS/EDGE/G/TCP-IP) Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/Y/FC 0-B 00-B MODEL 0-B 0-B 0-B 0-B 90-B 00-B 0-B Free- cycle Water circuit Electrical characteristics Unit with tank and pump Sound capacity () kw 8 8 9 Absorbed power () kw 8 9 8 8 0 EER ()....... Air temperature () C -. -.0 -.0 -. -. -.0 -. Absorbed power () kw 8 0 Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s...9 9.8.. 9. Pressure drops kpa 0 80 8 9 0 Water connections DN 00 00 00 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 9 9 Max. starting current A 8 0 0 Pump available static kpa 0 0 8 Tank water volume l 00 00 00 00 00 00 000 Water connections DN 00 00 00 0 STD version () db(a) With SL accessory () db(a) Transport weight () Kg 0 0 0 80 80 0 0 Operating weight () Kg 90 0 80 00 0 80 00 MODEL 00-B 0-B 0-B 80-B 0-B 00-B Free- cycle Water circuit Electrical characteristics Unit with tank and pump Sound capacity () kw 09 8 99 9 88 0 Absorbed power () kw 0 90 EER ().0.8.9...0 Air temperature () C -. -. -. -. -. -.9 Absorbed power () kw 0 9 Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s..9.8 8.88.8. Pressure drops kpa 0 0 00 00 Water connections DN 0 0 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 89 Max. starting current A 0 8 88 8 88 Pump available static kpa 00 0 0 0 0 Tank water volume l 000 000 000 --- --- --- Water connections DN 0 0 00 00 00 00 STD version () db(a) 9 9 9 9 80 With SL accessory () db(a) Transport weight () Kg 80 0 80 990 000 0 Operating weight () Kg 0 80 90 00 0900 90 DIMENSIONS 0-B 0-B 0-B 0-B 90-B 00-B 0-B 00-B 0-B 0-B 80-B 0-B 00-B L STD mm 00 00 00 00 0 0 00 000 000 000 000 00 00 W STD mm 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD mm 0 0 0 0 0 0 0 0 0 0 0 0 0 CLEARANCE AREA CHA/Y/FC 0-B 00-B 00 800 000 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at which the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. Electrical board side

FROM 0 KW TO 00 KW. CHA 0-V 0-V AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGER. The liquid Chillers and Heat Pumps of the CHA 0-V 0-V series are designed to satisfy the needs of large-sized service sector or industrial areas. They are used, in combination with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. Equipped with axial fans, Screw compressors and shell and tube exchanger, even in the super silent version, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. The use of large condensing coils and fans with high unit efficiency, as well as the optimization of the hydraulic and cooling circuit and the use of latest generation screw compressors, combined with a suitable sizing of the user system, allows to obtain high efficiency during operation with remarkably reduced energy consumption. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series. VERSION CHA only CHA/WP Reversible Heat Pump CHA/SSL Super silenced cooling only CHA/WP/SSL Super silenced reversible Heat Pump FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Screw compressors, with built-in oil separator, suction filter, cranckcase heater, oil sight glass and thermal protection. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. R0C refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Microprocessor control and regulation system. Digital high and low gauges. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement RZ s stepless control CT Condensing control down to 0 C CC Condensing control down to -0 C BT Low water temperature Kit HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU Single circulating pump PD Double circulating pump SPU Inertial tank and single circulating pump SPD Inertial tank and double circulating pump FE Antifreeze heater for evaporator FB FZ FH FU FD SS IS ISB ISBT ISL IAV Antifreeze heater for evaporator and tank Antifreeze heater for evaporator, single pump and pipes Antifreeze heater for evaporator, double pump and pipes Antifreeze heater for evaporator, tank, single pump and pipes Antifreeze heater for evaporator, tank, double pump and pipes Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal IAA Remote set-point, -0 ma signal IAS Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA 0-V 0-V MODEL 0-V 80-V 90-V 0-V 0-V 0-V 0-V 80-V 00-V 0-V (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 0 98 9 90 8 8 80 Absorbed power () kw 8 9 0 89 EER ()......0..9.8.8 capacity () kw 9 9 8 89 8 9 9 Absorbed power () kw 8 8 88 98 08 9 EER ()......8...8.8 ESEER...8..8.8.0..8. Heating capacity () kw 90 80 8 8 Absorbed power () kw 8 9 0 9 9 0 COP ()......8.80.8.8.9 Heating capacity () kw 90 8 8 80 8 Absorbed power () kw 8 9 0 8 0 COP ()..9.0.9.9.9...8.8 Quantity n Refrigerant circuits n Capacity steps n Water flow l/s 8. 9. 0.8..8. 8. 0.9.9.8 Pressure drops kpa 0 0 Water connections DN 0 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 8 0 8 0 9 8 Max. starting current A 90 8 0 9 8 9 Pump available static kpa 80 0 0 9 0 0 Tank water volume l 00 00 00 00 000 000 000 000 000 000 Water connections DN 00 00 00 00 00 00 0 STD version () db(a) With SL accessory () db(a) SSL version () db(a) 8 8 8 8 9 Transport weight Kg 0 0 0 80 0 0 80 90 0 Operating weight Kg 90 0 0 0 80 80 00 0 0 80 MODEL 0-V 0-V 0-V 0-V 0-V 00-V 0-V 0-V 00-V 0-V (EN) Heating Heating (EN) Evaporator Electrical characteristics Unit with tank and pump Sound capacity () kw 08 8 8 88 90 99 0 9 00 Absorbed power () kw 9 8 0 8 0 0 EER ().8.9.9.9.9.9.9.0.9.98 capacity () kw 0 8 8 90 989 0 9 9 Absorbed power () kw 8 8 09 9 08 EER ().8.88.90.9.9.9.90.98.9.9 ESEER.8.9.9.9.90.00..99.00. Heating capacity () kw 0 0 809 89 9 0 --- --- Absorbed power () kw 00 0 80 0 --- --- COP ().88.9.9.98.99.99.9. --- --- Heating capacity () kw 8 89 99 09 --- --- Absorbed power () kw 80 0 9 8 0 --- --- COP ().8.88.90.9.9.9.89.0 --- --- Quantity n Refrigerant circuits n Capacity steps n Water flow l/s 9.0.8. 9..8.0. 9.0.. Pressure drops kpa 8 0 8 Water connections DN 00 00 00 00 00 00 00 00 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 8 8 0 89 90 9 Max. starting current A 9 9 0 0 9 9 8 99 Pump available static kpa 0 0 0 00 80 0 0 Tank water volume l 000 000 000 000 000 000 000 000 000 000 Water connections DN 0 0 0 0 0 00 00 00 00 00 STD version () db(a) 8 8 8 8 8 8 8 8 With SL accessory () db(a) SSL version () db(a) 9 9 9 9 9 9 9 9 --- --- Transport weight Kg 0 0 90 890 0 90 80 90 90 Operating weight Kg 0 0 900 00 0 0 0 880 90 00 DIMENSIONS 0-V 80-V 90-V 0-V 0-V0-V0-V80-V00-V0-V0-V0-V0-V0-V0-V00-V0-V0-V00-V 0-V STD mm 0 0 0 0 00 00 0 0 0 00 00 0 8900 8900 000 000 000 0 00 00 L SSL mm 0 0 00 00 00 0 00 00 00 8900 8900 8900 000 000 000 0 0 00 --- --- WP mm 00 00 00 00 0 0 00 00 00 0 0 0 000 000 000 000 0 00 --- --- WP/SSL mm 00 00 0 0 0 00 0 0 0 000 000 000 000 000 000 00 00 --- --- --- W * STD/WP mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 --- --- WP/SSL mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 --- --- --- CLEARANCE AREA NOTES CHA 0-V 0-V 00 800 000 800 Electrical board side. Chilled water from to C, ambient air temperature C.. Heated water from 0 to C, ambient air temperature C d.b./ C w.b.. Sound level measured in free field conditions at m from the unit. According to ISO.. Length with inertial tank accessory. N.B. of SSL and WP versions and units with tank and pump are specified on technical brochure. * STD-SSL-WP-WP/SSL

FROM KW TO KW. CHA/FC 0-V 0-V AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, SCREW COMPRESSORS AND SHELL AND TUBE EXCHANGER. The liquid Chillers of the CHA/FC 0-V 0-V series offer innovative technology to meet the needs of large systems for industrial applications requiring the production of cooled water continuously year-round. During the cold months, in FREE-COOLING operation mode, the return liquid of the system is cooled directly by forced convection of outdoor air through the condensing coil, thus saving energy by not operating the unit s Screw compressors. A -way valve system is controlled by the electronic microprocessor controller, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE-COOLING) modes. VERSION CHA/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Screw compressors, with built-in oil separator, suction filter, cranckcase heater, oil sight glass and thermal protection. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. Digital high and low gauges. R0C refrigerant. Electrical board includes: main switch with door safety interlock, fuses, overload protection for compressors and thermocontacts for fans. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. Microprocessor control and regulation system. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers SL Unit silencement BT Low water temperature Kit RZ s stepless control HRT/P Total heat recovery in parallel TX Coil with pre-coated fins SP Inertial tank PU Single circulating pump PD Double circulating pump SPU Inertial tank and single circulating pump SPD SS IS ISB ISBT ISL IAV IAA IAS IDL CP Inertial tank and double circulating pump Soft start Modbus RTU protocol, RS8 serial BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/FC 0-V 0-V MODEL 0-V 80-V 90-V 0-V 0-V 0-V 0-V 80-V 00-V Free- cycle Water circuit Electrical characteristics Unit with tank and pump Sound capacity () kw 99 8 9 8 Absorbed power () kw 9 8 0 EER ()...0..8..0.. Air temperature () C 0.0 -. -. -. -. -.0 -. -. -. Absorbed power () kw 8 8 8 8 Quantity n Refrigerant circuits n Capacity steps n Water flow l/s 9. 0.9.8.8.9.0 9.9.8. Pressure drops kpa 9 0 8 Water connections G Power supply V/Ph/Hz 00//0 Max. running current A 8 0 8 8 0 9 Max. starting current A 90 8 0 0 9 8 Pump available static kpa 9 8 0 8 Tank water volume l 00 00 00 00 000 000 000 000 000 Water connections G STD version () db(a) With SL accessory () db(a) Transport weight () Kg 0 0 0 800 90 90 00 0 80 Operating weight () Kg 800 90 90 980 80 80 0 00 0 MODEL 0-V 0-V 0-V 0-V 0-V 0-V 00-V 0-V 0-V Free- cycle Water circuit Electrical characteristics Unit with tank and pump Sound capacity () kw 8 9 8 9 0 Absorbed power () kw 99 8 8 00 EER ().8......8.8. Air temperature () C -.0 -.0 -. -.8 -. -.0 -. -. -. Absorbed power () kw 0 0 8 8 8 8 Quantity n Refrigerant circuits n Capacity steps n Water flow l/s. 0..9..0. 8.8. 0. Pressure drops kpa 8 8 0 0 Water connections G 8 8 8 Power supply V/Ph/Hz 00//0 Max. running current A 8 8 0 89 Max. starting current A 9 9 0 0 9 9 Pump available static kpa 0 9 0 Tank water volume l 000 000 000 000 000 000 000 000 000 Water connections G 8 8 8 STD version () db(a) 8 9 80 9 9 80 9 With SL accessory () db(a) Transport weight () Kg 080 0 0 0 90 0 80 800 990 Operating weight () Kg 00 0 90 00 80 80 890 90 090 DIMENSIONS 0-V 80-V 90-V 0-V 0-V 0-V 0-V 80-V00-V0-V 0-V 0-V 0-V 0-V 0-V00-V0-V 0-V L STD mm 00 00 00 00 00 0 0 0 00 00 00 8900 8900 000 000 000 000 0 W STD mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD mm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CLEARANCE AREA CHA/FC 0-V 0-V 00 800 000 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at which the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO.. Unit without tank and pump. Electrical board side

FROM KW TO 0 KW. CHA/TTH 0-90- A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, TURBOCOR (MAGNETIC LEVITATION) COMPRESSORS AND FLOODED SHELL AND TUBE EXCHANGER. The innovative CHA/TTH 0-90- TURBOLINE units, with HFO-Rze refrigerant, are designed to provide an effective solution to highly selective system needs. The latest generation refrigerant HFO-Rze, with GWP< (Global Warming Potential), is the most environmentally sustainable refrigerant on the market, and meets the strictest international environmental regulations. Furthermore, thanks to Turbocor compressors, the units perform with top efficiency at partial loads, low inrush currents, an excellent silent functioning and reduced weight. The use of TURBOCOR dynamic partial-load oil-free magnetic levitation compressors managed by the TURBOSOFT self-adaptive electronic control, of shell tube evaporator and innovative heat exchangers, traditional or Microchannel, results in a high energy efficiency with unequalled ESEER/IPLV values, in the elimination of accumulation tanks and in an excellent silent functioning. Compared to traditional units, equipped with Screw compressors, TURBOLINE units have low operational costs during their entire operating period, even lower than 0%. Besides, the units are equipped with a WEB MONITORING system for the monitoring and remote management of the units through the GPRS/ EDGE/G/TCP-IP communication protocol. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSION CHA/TTH only CHA/TTH/MC only with MICROCHANNEL coils FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in INVERTER, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils or aluminium MICROCHANNEL coils. High efficiency flooded shell and tube type evaporator, with one or two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. HFO-Rze refrigerant. Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermocontacts for the fans, relay and terminals for external connections. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. TURBOSOFT control and regulation system is fitted with RS8 serial and Web Monitoring device for remote monitoring via GPRS/ EDGE/G/TCP-IP network. ACCESSORIES 8 FACTORY FITTED ACCESSORIES IM Automatic circuit breakers EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins TXB Coil with epoxy treatment PU Single circulating pump PD Double circulating pump FE Antifreeze heater for evaporator FZ FH TS ISB ISBT ISL IAV IAA Antifreeze heater for evaporator, single pump and pipes Antifreeze heater for evaporator, double pump and pipes Touch screen BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal IAS Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/TTH 0-90- MODEL 0-0- 80-0- 0-0- 90-80- 0-90- capacity () kw 0 000 0 0 0 STD version Absorbed power () kw 9 9 8 80 9 8 EER ()...0.....0.. STD version (EN) MC version MC version (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 8 99 8 Absorbed power () kw 9 9 8 8 9 8 EER ().9......... ESEER.0.8.8..0..9.0.9.99 EUROVENT Class A A A A A A A A A A capacity () kw 0 000 0 0 0 Absorbed power () kw 89 8 8 0 EER...9.0.0.9..9.0. capacity () kw 9 8 8 99 9 8 Absorbed power () kw 90 8 9 0 8 EER ().......... ESEER.9.0......9..99 EUROVENT Class A A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s..0.0.0..8.0.0.0.0 Pressure drops kpa 0 0 0 0 Water connections DN 00 00 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 9 0 0 8 9 8 Max. starting current A 9 99 0 9 99 0 Pump available static kpa 0 0 0 0 0 0 Water connections DN 00 00 0 0 0 0 00 0 0 00 STD version () db(a) 0 0 MC version () db(a) 9 9 0 0 0 0 0 0 Transport weight Kg 0 000 00 0 00 80 800 90 00 800 Operating weight Kg 0 00 0 80 0 00 800 90 80 800 DIMENSIONS 0-0- 80-0- 0-0- 90-80- 0-90- L STD/MC mm 000 000 00 00 800 000 00 00 00 00 W STD/MC mm 00 00 00 00 00 00 00 00 00 00 H STD/MC mm 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/TTH 0-90- 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. Data of MC version are specified on technical brochure. Electrical board side 9

FROM 9 KW TO 8 KW. CHA/TTH/FC 0-90- AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, TURBOCOR (MAGNETIC LEVITATION) COMPRESSORS AND FLOODED SHELL AND TUBE EXCHANGER. The innovative CHA/TTH/FC 0-90- TURBOLINE units, with HFO-Rze refrigerant and FREE-COOLING technology, are designed to provide an effective solution to installation requirements of large areas, both commercial and industrial, where the production of chilled water is required in continuous service throughout the year. The latest generation refrigerant HFO-Rze, with GWP< (Global Warming Potential), is the most environmentally sustainable refrigerant on the market, and meets the strictest international environmental regulations. Furthermore, thanks to Turbocor compressors, the units perform with top efficiency at partial loads, low inrush currents, an excellent silent functioning and reduced weight. The unit, designed with specific attention to every aspect of construction and combined with the use of TURBOCOR dynamic partialization oil-free magnetic levitation compressors - managed by the TURBOSOFT self-adaptive electronic control - and with the use of flooded shell & tube evaporator, achieves a high rate of energy efficiency, with unequalled ESEER/IPLV values, without using accumulation tank and has an excellent silent functioning. Depending on outside air temperature, the microprocessor controller manages the functioning in CHILLER, FREE-COOLING or MIXED (both CHILLER and FREE-COOLING) mode. The units are also equipped with a WEB MONITORING system for the monitoring and remote management of the units through the communication protocol GPRS/EDGE/G/TCP-IP. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSION CHA/TTH/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in INVERTER, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. High efficiency flooded shell and tube type evaporator, with one or two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. HFO-Rze refrigerant. Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermocontacts for the fans, relay and terminals for external connections. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. TURBOSOFT control and regulation system is fitted with RS8 serial and Web Monitoring device for remote monitoring via GPRS/ EDGE/G/TCP-IP network. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers EC EC Inverter fans HRT/P Total heat recovery in parallel TX Coil with pre-coated fins PU Single circulating pump PD Double circulating pump TS Touch screen ISB BACnet MSTP protocol, RS8 serial ISBT ISL IAV IAA IAS IDL CP BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch 0

CHA/TTH/FC 0-90- MODEL 0-0- 80-0- 0-0- 90-80- 0-90- Free- cycle Water circuit Electrical characteristics Unit with pump capacity () kw 9 8 98 8 00 8 98 8 Absorbed power () kw 9 0 9 8 8 0 9 8 EER ().......8...8 Air temperature () C.0.. -.0 0.0 0. -.0. -.0 -.0 Absorbed power () kw 0.8......0...0 Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s..98 8..0... 8..0. Pressure drops kpa 88 0 8 9 0 8 9 Water connections DN 00 00 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 8 0 0 8 8 Max. starting current A 99 99 0 99 99 0 Pump available static kpa 0 0 80 0 0 0 0 80 0 Water connections DN 00 00 0 0 0 0 00 0 0 00 Sound STD version () db(a) 9 0 Transport weight Kg 0 0 0 0 890 890 0800 0 80 000 Operating weight Kg 900 00 00 0 80 980 80 0 0 00 DIMENSIONS 0-0- 80-0- 0-0- 90-80- 0-90- L STD mm 000 000 00 00 800 000 00 00 00 00 W STD mm 00 00 00 00 00 00 00 00 00 00 H STD mm 0 0 0 0 0 0 0 0 0 0 CLEARANCE AREA CHA/TTH/FC 0-90- 00 800 000 800 NOTES. Chilled water (with ethylene glycol at 0%) from to 0 C, ambient air temperature C.. Ambient air temperature at wich the cooling capacity indicated in point () is reached.. Sound level measured in free field conditions at m from the unit. According to ISO. Electrical board side

FROM 8 KW TO KW. CHA/TTY 0-00- A CLASS ENERGY EFFICIENCY AIRCOOLED LIQUID CHILLERS WITH AXIAL FANS, TURBOCOR (MAGNETIC LEVITATION) COMPRESSORS AND FLOODED SHELL AND TUBE EXCHANGER. The innovative CHA/TTY 0-00- TURBOLINE units, with Ra refrigerant, are designed to provide an effective solution to highly selective system needs. Efficiency at partial loads, low inrush currents, an excellent silent functioning, reduced weight and the specific design and handling of every manufacturing aspect make the TURBOLINE series the top unit of the range. The use of TURBOCOR dynamic partial-load oil-free magnetic levitation compressors managed by the TURBOSOFT self-adaptive electronic control, of shell tube evaporator and innovative heat exchangers, traditional or Microchannel, results in a high energy efficiency with unequalled ESEER/IPLV values, in the elimination of accumulation tanks and in an excellent silent functioning. Compared to traditional units, equipped with Screw compressors, TURBOLINE units have low operational costs during their entire operating period, even lower than 0%. Besides, the units are equipped with a WEB MONITORING system for the monitoring and remote management of the units through the GPRS/ EDGE/G/TCP-IP communication protocol. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSION CHA/TTY only CHA/TTY/MC only with MICROCHANNEL coils FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in INVERTER, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. Axial fans directly coupled to an electric motor with external rotor. Condenser made of two copper tube and aluminum finned coils or aluminium MICROCHANNEL coils. High efficiency flooded shell and tube type evaporator, with one or two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermocontacts for the fans, relay and terminals for external connections. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. TURBOSOFT control and regulation system is fitted with RS8 serial and Web Monitoring device for remote monitoring via GPRS/ EDGE/G/TCP-IP network. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers EC EC Inverter fans HR Desuperheater HRT/S Total heat recovery in series HRT/P Total heat recovery in parallel TX Coil with pre-coated fins TXB Coil with epoxy treatment PU Single circulating pump PD Double circulating pump FE FZ FH TS ISB ISBT ISL IAV Antifreeze heater for evaporator Antifreeze heater for evaporator, single pump and pipes Antifreeze heater for evaporator, double pump and pipes Touch screen BACnet MSTP protocol, RS8 serial BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal IAA Remote set-point, -0 ma signal IAS Remote signal for second set-point activation IDL Demand limit from digital input CP Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch

CHA/TTY 0-00- MODEL 0-0- 0-0- 0-0- 00-0- 0- STD version STD version (EN) MC version MC version (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 8 8 0 09 0 99 0 Absorbed power () kw 8 9 0 8 EER ().0.8...9.9.8.9. capacity () kw 8 0 0 9 0 Absorbed power () kw 8 98 88 8 EER ()...0...... ESEER....9.9.0...8 EUROVENT Class A A A A A A A A A capacity () kw 8 8 0 09 0 99 0 Absorbed power () kw 8 0 98 8 EER.88.8.90.80.8.8.89.8.8 capacity () kw 8 8 0 09 0 99 0 Absorbed power () kw 8 0 98 8 EER ().88.8.90.80.8.8.89.8.8 ESEER.9.9..0..0..0. EUROVENT Class A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s.8..0 9.. 9.9.9.9. Pressure drops kpa 0 0 8 Water connections DN 00 00 00 0 0 0 0 Power supply V/Ph/Hz 00//0 Max. running current A 8 8 8 0 09 Max. starting current A 9 80 88 Pump available static kpa 9 0 00 9 9 0 0 Water connections DN 00 00 00 0 0 0 0 STD version () db(a) 9 9 9 9 0 0 0 9 0 MC version () db(a) 8 8 8 8 9 9 9 8 9 Transport weight Kg 0 0 0 90 90 00 0 0 0 Operating weight Kg 0 0 900 90 0 0 90 80 MODEL 80-00- 0-0- 00-0- 0-80- 00- STD version STD version (EN) MC version MC version (EN) Evaporator Electrical characteristics Unit with pump Sound capacity () kw 0 09 0 99 0 0 Absorbed power () kw 8 09 EER ().8...9.8.9.8.8. capacity () kw 0 0 9 0 0 Absorbed power () kw 9 88 8 9 EER ()......... ESEER..8.......0 EUROVENT Class A A A A A A A A A capacity () kw 0 09 0 99 0 0 Absorbed power () kw 8 8 98 9 8 8 EER.8.8.8.8.89.8.8.8.8 capacity () kw 0 09 0 99 0 0 Absorbed power () kw 8 8 98 9 8 8 EER ().8.8.8.8.89.8.8.8.8 ESEER.90..9.8.9...9.0 EUROVENT Class A A A A A A A A A Quantity n Refrigerant circuits n Capacity steps n Stepless Water flow l/s 0.0 9.. 9.9.9.9. 0.0 9. Pressure drops kpa 0 9 8 0 9 Water connections DN 00 00 0 0 0 0 00 00 Power supply V/Ph/Hz 00//0 Max. running current A 8 00 9 09 0 8 00 Max. starting current A 8 9 80 88 0 Pump available static kpa 0 9 9 0 0 0 Water connections DN 00 00 0 0 0 0 00 00 STD version () db(a) 0 0 0 9 0 MC version () db(a) 0 0 9 9 9 8 9 0 0 Transport weight Kg 0 0 00 0 0 80 90 0 80 Operating weight Kg 0 880 8 0 00 9 80 809 DIMENSIONS 0-0- 0-0- 0-0- 00-0- 0-80- 00-0- 0-00- 0-0- 80-00- L STD/MC mm 000 000 000 000 00 00 00 800 000 00 00 00 00 00 800 000 00 00 W STD/MC mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 H STD/MC mm 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 CLEARANCE AREA CHA/TTY 0-00- 00 800 000 800 NOTES. Chilled water from to C, ambient air temperature C.. Sound level measured in free field conditions at m from the unit. According to ISO. N.B. Data of MC version are specified on technical brochure. Electrical board side

FROM KW TO KW. CHA/TTY/FC 0-00- AIRCOOLED LIQUID CHILLERS FREE-COOLING WITH AXIAL FANS, TURBOCOR (MAGNETIC LEVITATION) COMPRESSORS AND FLOODED SHELL AND TUBE EXCHANGER. The innovative CHA/TTY/FC 0-00- TURBOLINE units, with Ra refrigerant and FREE-COOLING technology, are designed to provide an effective solution to installation requirements of large areas, both commercial and industrial, where the production of chilled water is required in continuous service throughout the year. The unit, designed with specific attention to every aspect of construction and combined with the use of TURBOCOR dynamic partialization oil-free magnetic levitation compressors - managed by the TURBOSOFT self-adaptive electronic control - and with the use of flooded shell & tube evaporator, achieves a high rate of energy efficiency, with unequalled ESEER/IPLV values, without using accumulation tank and has an excellent silent functioning. Depending on outside air temperature, the microprocessor controller manages the functioning in CHILLER, FREE-COOLING or MIXED (both CHILLER and FREE-COOLING) mode. The units are also equipped with a WEB MONITORING system for the monitoring and remote management of the units through the communication protocol GPRS/EDGE/G/TCP-IP. Users enabled to the use of this service can, by using a specific webpage, have access to the Monitoring, Managing and Statistics activities. VERSION CHA/TTY/FC only FEATURES Self-supporting galvanized steel frame protected with polyester powder painting. Semi-hermetic centrifugal compressors with dual Turbocor turbine, oil free, magnetic rising rotor, thermal protection, flow and delivery tap, continuous capacity adjustment system thanks to built-in INVERTER, automatic anti-cavitation system. The power circuit of the compressor is fitted with a set of electrolytic condensers to control the rising in the event of a power failure, reactor for the power factor correction, EMI filter for electromagnetic compatibility. Axial fans directly coupled to an electric motor with external rotor. Condenser made of FREE-COOLING copper tube and aluminium finned coil. High efficiency flooded shell and tube type evaporator, with one or two independent circuits on the refrigerant side and one on the water side, complete with water differential switch. circuit shut-off valves on suction, discharge and liquid line. Electronic thermostatic valve. Digital high and low gauges. Ra refrigerant. Electrical board includes: main on-off switch with door lock, fuses, electronic/digital overload device to protect the compressors and thermocontacts for the fans, relay and terminals for external connections. Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -0 C. TURBOSOFT control and regulation system is fitted with RS8 serial and Web Monitoring device for remote monitoring via GPRS/ EDGE/G/TCP-IP network. ACCESSORIES FACTORY FITTED ACCESSORIES IM Automatic circuit breakers EC EC Inverter fans HRT/P Total heat recovery in parallel TX Coil with pre-coated fins PU Single circulating pump PD Double circulating pump TS Touch screen ISB BACnet MSTP protocol, RS8 serial ISBT ISL IAV IAA IAS IDL CP BACnet TCP/IP protocol, Ethernet port LonWorks protocol, FFT-0 serial Remote set-point, 0-0 V signal Remote set-point, -0 ma signal Remote signal for second set-point activation Demand limit from digital input Potential free contacts LOOSE ACCESSORIES MN High and low gauges CR Remote control panel RP Coil protection metallic guards AG Rubber shock absorbers AM Spring shock absorbers FL Flow switch