Versatile laser Raman Spectrometer. RMP-500 series

Similar documents
ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise

Modular Approach and Customized solutions (near field, UV-VIS, etc.)

Attachable to other Advanced analytical tools (e.g AFM, XRD, SEM etc.) Detect and measure deposits in liquid as it is (Particle ID Detection)

Imaging Spectrometers

MonoVista CRS+ Raman Microscopes

Series Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Renishaw invia Raman Microscope (April 2006)

Confocal Raman Microscope RAMOS

Modular Raman Spectrometers

Depth analysis for laminated film by confocal Raman mapping

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

Confocal Raman Systems SPECTROSCOPY GROUP

Portable Benchtop Raman Instruments Agility Series

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy

Raman Lab - Laser 1 operation

Thermo Scientific DXR2 Raman Family

FLEX 2 NEW. Key points. 3D Confocal Raman, 2 lasers, fiber based, AFM combined

Introduction to. 3D Scanning Confocal Microscope with Spectrometer

WITec Raman Spectroscopy Solutions

Raman Sample Holders

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Apex High Performance Spectrometer

Easy integration into complex experimental setup

Overview. Etalon-Based FSRS Setup APPLICATION NOTE

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter

Monochromator & Imaging Spectrograph

SYNCERITY TM 1024 x 256

Spectrograph overview:

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

SIMPLE USER GUIDE RAMAN INSTRUMENT

Confocal Raman Imaging with WITec Sensitivity - Resolution - Speed. Always - Provable - Routinely

X-Ray fluorescence and Raman spectroscopy

195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.

High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology

Optical properties and characterization

LASER RAMAN SPECTROSCOPY

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

LS-785 High Throughput Lens Spectrograph User Manual

DXR SmartRaman Spectrometer

CinCam CCD - Technical Data -

Appendix 1. Adding objectives to enable their use with Surface

Navigator. The Navigator

Introduction of the Industry's Broadest Tunable Quantum Cascade Lasers. February Block Engineering 1

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014

WAVELENGTH MANAGEMENT

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

MultiView 2000 TM. The First Tip and Sample Scanning Probe Microscope. The Next Evolution in SPM. The Next Evolution in SPM

Micro Raman Measurement system

LabRAM Series. Follow the Experts

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

Company Presentation Optical Components

NIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

All Series Video Measuring Machine

TABLE OF CONTENTS PRODUCT DESCRIPTION LASERDEC CL200 / CL200HP TECHNICAL DATA DIMENSIONS LASERDEC CL500 / CL500HP TECHNICAL DATA DIMENSIONS

Physics 625 Femtosecond laser Project

Performance Improvement of a 3D Stereo Measurement Video Endoscope by Means of a Tunable Monochromator In the Illumination System

Scanned by CamScanner

ProEM -HS:1KBX3-10µm

ProEM -HS:1024BX3 FEATURES BENEFITS

Progress of the Thomson Scattering Experiment on HSX

Overview and History Research Focus OEM / Instrumentation Capability Lean Manufacturing principles andor Pioneering EMCCD Technology

Xantus & FirstGuard Handheld Raman Analyzers

Beam Analysis Camera Based Beam Propagation Analyzer: M Automatic M 2 - at Production Speeds. Manual M 2

The latest trend of hybrid instrumentation

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

Operating Procedure for Horiba Raman Microscope

Introduction to Diffraction Gratings

Section V: AD Series Detection Systems

Specifications. Wavelength range (nm) Focal length (mm) 195. Aperture F/7. Spectral resolution (λ/ λ) 1 (corresponding to 3 pixels FWHM)

Silicon Avalanche Photodiodes in Dynamic Light Scattering

Control of Light. Emmett Ientilucci Digital Imaging and Remote Sensing Laboratory Chester F. Carlson Center for Imaging Science 8 May 2007

Light Sources opmaak.indd :32:50

LabSpec 6. Spectroscopy Suite. Simply Powerful Software

UK Industrial Vision SWIR Challenges

WAVELENGTH MANAGEMENT

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

phoenix Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

PyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.

VibroFlex Compact Compactness meets versatility Preliminary datasheet. VibroFlex Compact

More Precision. optoncdt // Laser displacement sensors (triangulation)

Lenses for Machine Vision

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

ksa ICE - Integrated Control for Epitaxy

Non-Contact Depth Measuring Microscope System DH2/IMH

Chemical Characterization of Pharmaceutical Samples by Confocal Raman Microscopy and Correlative Techniques

Certus Optic. NanoScanTechnology. Basic Datasheet. reasoned innovations. Integrated Optical and Scanning Probe Microscope

The 3rd Dimension at the Speed of Light. Laser Processing Head RLSK

LLA Instruments GmbH. Multiplexed Near-Infrared-Spectrometer KUSTA 4004M. Product description

OTO Photonics. Sidewinder TM Series Datasheet. Description

Manual Infrared viewers ABRIS M series M1300 M1700 M2000

LaserBeam ProfilingSolutions. UV/VIS/NIRLaserBeam Profiler

Dual Fiber SWIR Laser Doppler Vibrometer

Jasco 4700 FTIR. Laser Spectroscopy Labs. Jasco 4700 FTIR. Operation instructions. Laser Spectroscopy Labs, UCI

Mu lt i s p e c t r a l

MODELING LED LIGHTING COLOR EFFECTS IN MODERN OPTICAL ANALYSIS SOFTWARE LED Professional Magazine Webinar 10/27/2015

Spraybase Technical Specifications Sheet

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

QUANTITATIVE PHASE IMAGING OF BIOLOGICAL CELLS USING OFF-AXIS METHOD OF WIDE FIELD DIGITAL INTERFERENCE MICROSCOPY (WFDIM)

Transcription:

Versatile laser Raman Spectrometer RMP-500 series

About RMP-500 RMP-500 series is a compact and versatile laser Raman spectrometer consisting of a micro Raman probe connected through fiber optics to the excitation laser, and the spectrograph (polychromator + CCD detector). The use of fiber probe allows the maximum flexibility, making it possible to meet a wide range of applications in many different fields. Observation camera built-in probe Spectrometer (with laser and detector) Light blocking door with laser interlock Small size manual XYZ stage Aspect of RMP-510 system

RMP-500 series lineup RMP 510 Universal system for a wide range of applications (from Raman spectra to photoluminescence) Laser wavelength: 532nm, Resolution: 2 cm -1, Measurement range: 100-8000 cm -1 RMP 520 Raman system mounting a 785nm laser which is useful for fluorescence reduction Laser wavelength: 785 nm, Resolution: 2 cm -1, Measurement range: 100-3500 cm -1 RMP 530 Excitation system is using a 1064 nm laser for extreme fluorescence reduction Laser wavelength: 1064 nm, Resolution: 5 cm -1, Measurement range: 100-3500 cm -1 * These specifications are valid in case of standard configuration.

Feature of RMP-500 series (1) Customization of the system according to purpose The use of remote fiber probe allows the measurement in an existing experimental system or in a process plant environment allowing the sampling in the proximity of the object of interest; up to 100 meters length fiber optics can be used. Connection to a sample compartment or to a microscope are also possible. Easy non-destructive and in-situ measurement The system is useful for measurement under high-temperature and pressure conditions or of dangerous/toxic materials as sampling through glass or plastic containers is possible. Adoption of newly-developed spectrometer A high quality spectroscopic system aberration-free was developed for the purpose. Allowing the detection of very small differences on the spectra which are impossible to detect by most handheld Raman systems. High end applications such as organic crystal with complex spectra or analysis of new materials are supported.

The features of RMP-500 series (2) Sample observation by internal camera The Raman spectroscopy is an analytical method, based by the irradiation of the sample through laser light and the detection of the light scattered light by the sample. RMP-500 series uses a probe mounting a subminiature CCD camera allowing the observation of the sample surface on a micrometric scale. The observation image is saved with measurement data. 20 µm spot (RMP-510) Figure Example of Measurement data by RMP-510 (Sample: Carbon powder)

The features of RMP-500 series (3) Fluorescence reduction by confocal optical system When a sample stored in a bottle or a chamber needs to be measured, it might be difficult to obtain the target spectrum due to the interference of the fluorescence from bottle. RMP series is adopting a confocal optical system reducing the interfering light. The diameter of laser spot is smaller than in case of other similar systems, thus it is possible to use it as a scaled-down Raman microsope. Ethanol Light-resistant bottle General probe Raman of light-resistant bottle RMP probe Spectrum obtained by RMP probe Spectrum obtained by commercial probes Ethanol (Standard data) Measurement example of ethanol in a light-resistant bottle Only the strong peak of ethanol is detected by using a commercial probe due to the Raman and Fluorescence from the light-resistant bottle, but it is possible to detect the weak peak by using RMP probe due to its excellent spatial resolution.

RMP-500 probe Probe head Sample compartment XYZ Stage Contactless measurement by using RMP probe Monitoring for process of chemical reaction into the flask It is possible to use a commercial probe as option. (Sample image observation is not possible) It is possible to measure a big sample by using the probe removed from standard stand

Software in RMP-500 series High capability and Easy operation software in Spectra Manager II. Measurement: Preview function, Objective mode, Spectra preview function, Microscope observation mode, Cosmic lay elimination, Auto fluorescence correction etc,,. Data Analysis : Smoothing, Base line correction, Curve fitting etc,,. Optional program : Interval measurement / Analysis program, Thermal change interval measurement / Analysis program, PLC quantitative analysis program, PCR quantitative analysis program, KnowItAll etc,,.

RMP-500 Specification Model RMP-510 RMP-520 RMP-530 Monochrometer / Spectrograph Wave number control mechanism Czerny-Turner type monochrometer /f =200mm High accurate rotary encoder type Direct Drive Wavelength Range (Rama shift) 100-8000cm-1 100-3500cm-1 100-3500cm-1 Monochrometer Resolution 2cm-1 2cm-1 5cm-1 (Option : 2.6 cm-1) Gratings 900gr/mm 400gr/mm 150gr/mm Optional gratings Number of gratings 2400 1800 1200 900 600 400 300 150gr/mm, Selectable type Max.4 gratings as automated change Detector Element 1650x200 (CCD detector) 1024 (InGaAs detector) Cooling methods Electric cooling (~-60 ) Electric cooling (~-60 ) Or Liquid N2 cooling (~-100 ) Laser wave number 532nm 785nm 1064nm Light Source Laser power 20mW 100mW 600mW Attenuator Manual: OPEN, OD4, OD1, OD0.3, CLOSE, Auto inter lock shutter Image magnification Long distance movable objective lens : x 20 ( Option : x 50, x 100) NIR Objective lens : x 20 Fiber Probe Beam diameter Fiber Sample observation Approx. 20um( x 20 objective lens condition) Single core,1m (Option : 3m, 5m,10m) CCD video camera Observation magnification x 250 (with 15 inch monitor, x 20 objective lens, resolution 1024 x 768) Probe headstand Software XYZ manual stage Stage size Laser safe OS Standard function Search function Optional program X,Y:+/- 4mm, Z: +/- 1.5mm 50mmΦ Class1, Inter lock mechanism Windows 7 Professional Spectrum measurement / analysis, JASCO Canvas, Validation, User advice, etc.. Sadtler KnowItAll search ( Spectrum search, Structure search, User data base, 600 standard data base, etc..) Interval measurement analysis, Carbon analysis, poly-silicon analysis, thermal measurement, etc.. Dimension / Weight 500(W)X360(D)X290(H) 30kg 500(W)X360(D)X290(H) 30kg 580(W)X360(D)X290(H) 30kg Power supply AC100V±10V 200VA

Various dedicated systems Reaction monitor system Customized dedicated system Automated drug detection RMP-510 Standard system Macro sample compartment type Standalone Microscope Field measurement type Raman microscope system Other solutions