Blackout Shutter Kits with Breathable Wall Light Traps

Similar documents
Blackout Shutter Kits with Breathable Wall Light Traps

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Installing the Cisco MDS 9020 Fabric Switch

Schwintek Bed Tilt OEM INSTALLATION MANUAL

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

INSTALLATION INSTRUCTIONS

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Extra Large Full Motion TV Mount for Televisions

Installation Instructions Access Dual Roller FlexShade System by Draper

DYNAVISION D2 TM INSTALLATION MANUAL

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Shop Fox Fence Kit Installation Instructions:

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Cycles Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Biesemeyer Fence Kit Installation Instructions:

Table of Contents: TOPIC: Safe Operation: READ THIS FIRST Page: 3 Warranty 4 Specifications 4 Installation 5-7 Operating Instructions 8 Parts Diagram

The Minimalist, Modular, Wall-Mounted Standing Desk

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

Quad Monitor Desk Stand - 13" to 24" Installation Instructions

INSTALLATION INSTRUCTIONS

System Storage EXP3000 Rack Installation Instructions

C764i Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Rolling Shutter Installation Manual Complete Technical Guide Please read before installing rolling shutters

Assembly and Setup Manual

i-series Videoconference Fixture

Innovative Americans, LLC. HD Media Pack Installation Manual

LARGE S URGE-PROTECTOR S HELTER

Assembly and Setup Manual

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

Eaton LCD Lift Flat Panel Display System. Installation Guide

Model 7416LED

Formulate Designer Series 20 Backwall - Kit 11

SNOWBOARD RACK KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 25

CHAPTER 3B: ELECTRONIC POWER STEERING

Star Trac Fitness E-ST 5090 Stepper. Install Guide

TRC-190 User s Manual

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

Manual No: Revision: D. Mag Retrofit Probe. Installation Guide

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

Flat Panel Static Wall Mount MSP-SS (GSM-210)

MBE Mounts and Adapters

A note about our online installation instructions:

Replacing the Encoder Strip

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

xtablet T1600 Vehicle Holder Installation Guide

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Titan Media Cart. Installation and Operation Manual

SERVICE PARTS MANUAL

FLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N

Removal and Installation8

Pronto Air Personal Transporter

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

CHAPTER 5 UNIT MAINTENANCE INSTRUCTIONS

Installing the Cisco SFS 3504 Server Switch

FLEXBOX. Installation Guide

LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS

Plasma Panel Replacement Guide DU-42PX12X

Elecraft W1 SWR/Wattmeter Enclosure by W8FGU

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

Installation Instructions

Operating Instructions

SERVICE PARTS MANUAL

Parts Manual Kleen Sweep 28 - Model Battery

MBX INSTRUCTION MANUAL. Please read this manual carefully before using the MBX! Mid-range studio stand

3M DSLAM Mounting Bracket Kit J0746

Basketball Shot Clock Set LX2180 Manual

Control Box Setup - PRSalpha

Attaching DX Encoders to your Majestic Carriage

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

HQuad500 Frame Assembly Guide

DIGITAL Server Rackmount Installation Guide

Thanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque)

Instruction Manual January milltronics MLC BELT SCALE

SAVE THESE INSTRUCTIONS

INSTALLATION GUIDE. Timberlane, Inc. 150 Domorah Drive, Montgomeryville, PA Timberlane.com

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

Motorized Ceiling TV Mount

Installation and User Guide

Rack Installation Instructions

Float Pod Installation Manual

Keysight M8000 Series BER Test Solutions

G12/G12x USER S MANUAL

Fixed Camera Housing. Installation. Customer Support. Parts Required. Tools Required. Procedure. If you need assistance... Installation Guide

edrive RAM Battery Alternate Replacement Procedure

Mounting on the Ceiling Using Flush Mount (Face Down)

Delta Unifence Kit Installation Instructions

ft Aspen Fir Item # Commercial ITEM Lights

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

KRONOS INSTALLATION INSTRUCTIONS

Digital Menu Board Wall Mount Installation Instructions

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

AlphaGateway SMG-01PE Quick Start Guide

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Quicksilver 606 TR-606 CPU Upgrade

Transcription:

Blackout Shutter Kits with Breathable Wall Light Traps 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Maintain controlled airflow without sacrificing blackout environments. BLACKOUT SHUTTER KITS 115426 & 115426A 115427 & 115427A 115428 & 115428A *Actual kit components may differ from the example shown. 1

Important Information READ THIS DOCUMENT BEFORE YOU BEGIN Thank you for purchasing the breathable wall light trap and blackout shutter kit. When properly assembled and maintained, this product will provide years of reliable service. These instructions include helpful hints and important information needed to safely assemble and properly maintain the kit components. Please read these instructions before you begin. If you have any questions during the assembly, contact Customer Service at 1.800.245.9881 for assistance. SAFETY PRECAUTIONS Wear eye protection. Wear gloves when handling metal parts. Use a portable GFCI (Ground Fault Circuit Interrupter) when working with electric power tools and cords. REQUIRED TOOLS The following list identifies the main tools needed to assemble and install the breathable wall light trap and kit components (if applicable). Additional tools may be needed. Tape measure and marker. Variable speed drill (cordless with extra batteries works best) & 1/4" drill bit. Small hammer and gloves. Level (length depends on kit dimensions). 7/16" wrenches and a socket set containing 7/16" deep-well socket. Wrench set and pliers. Rivet gun. Opaque caulk or duct tape. ASSEMBLY PROCEDURE Following the instructions as presented will help ensure proper assembly. Steps outlining assembly process are as follows: 1. Verify that all parts are included in the shipment. Notify customer service for questions or concerns. 2. Read these instructions and all additional documentation included with the shipment before you begin. 3. Gather the tools and assistants. Assistants are needed to lift and hold assembly when attaching to building frame. 4. Assemble kit components. Read this document to determine what pages apply to your kit. 5. Read the care and maintenance information. CARE AND MAINTENANCE Proper care and maintenance is important. Check the following items periodically to ensure breathable wall light trap components are secure and functioning properly. Check all fasteners to verify they remain tight. Never climb or stand on any part of the light trap and its frame components. Ensure nothing blocks either side of light trap. Inspect all electrical connections and wires. Repair or replace as needed. Repair or replace loose or broken wires. For replacement or missing parts, call 1.800.245.9881 for assistance. WARNING: IF KIT INCLUDES MOTORIZED SHUTTER OR AN ELECTRIC FAN, CONSULT THE SERVICES OF A QUALIFIED ELECTRICIAN TO ADEQUATELY AND SAFELY CONNECT COMPONENTS TO A POWER SUPPLY. ALL ELECTRICAL CIRCUITS SHALL BE DESIGNED IN ACCORDANCE WITH LOCAL AND REGIONAL BUILDING CODES AND STANDARDS. 2 115426_115427_115428

Getting Started: Basic Kit Descriptions and Components Different kits include different components. Use the information on this page to identify which procedures apply to your breathable wall light trap kit. Kit numbers that end with the letter A (e.g., 115424A) include an assembled light trap. Skip Sections 1 & 2 if your kit includes an assembled light trap. This guide describes the assembly and installation of these blackout shutter kits: Outside Building 115426 & 115426A 115427 & 115427A 115428 & 115428A GENERAL ASSEMBLY STEPS 1. Assemble vane kit components. (All kits: Procedure 1. Does not apply if kit number ends with letter A.) 2. Assemble vane kit frame. (All kits: Procedure 2. Does not apply if kit number ends with letter A.) 3. Attach shutter assembly to frame. 4. Attach shutter motor to frame. See instruction sent with motor and shutter. 5. Attach cable to shutter. Light Trap Frame Column Light Trap 6. Attach assembled breathable wall light trap to frame. ATTENTION: Light trap is inside the building when properly installed. Shutter 7. Attach cable to shutter motor. Shutter Motor Inside Building End Wall Cladding 115426_115427_115428 3

Getting Started: Parts PICTORIAL PARTS GUIDE FAG304B 1/4" Hex Bolt FAME50B 1/4" Flat Washer FA4484B Tek Screw DE4007 Sealant *Some parts are not shown. 100441 Nut Setter 116139 Rivet 4 115426_115427_115428

Assembly Instructions: Vane Kit Components 1 ASSEMBLE LIGHT TRAP VANE KIT COMPONENTS ATTENTION: If kit number ends with letter A, light trap is preassembled. Skip Procedures 1 & 2 and continue with Procedure 3. Depending on size, vane kits are identified by one of these numbers: 113397, 113411, 113423, 113439, or 113450. Gather vane kit components. Review part descriptions for additional information. Complete these steps: 1. Unpack vanes keeping them in the same order as packed. 4. Slide a tube spacer onto each rod and add another vane. 5. Repeat Step 4 until all vanes are used. 2. Place one (1) rod cap nut firmly on one end of a rod. Use a nut driver (or similar tool) and a hammer to seat cap on rod. Repeat to install a cap on one end of each remaining rods. 6. After installing all vanes, install a cap nut on the end of each rod to secure final vane. 3. With assistance, stand rods upright with cap nuts at the bottom. Place one vane over all rods. Vane Spacer ATTENTION: Before installing cap nut, determine if a 3/8" spacer is needed. Vanes should be tight once final cap nut is installed. Cap Nut 7. Finally, turn assembled vane kit so vanes are vertical. 8. Continue by assembling vane kit frame. See Procedure 2. 115426_115427_115428 5

Assembly Instructions: Vane Kit Frame 2 ASSEMBLE LIGHT TRAP VANE KIT FRAME Gather parts: ATTENTION: If kit number ends with letter A, light trap 116139 rivets is pre-assembled. Skip Procedures 1 & 2 and continue with Procedure 3. Light trap frame top/bottom panels (2) Complete these steps: Light trap frame side panels (2) 1. Use diagram below to assemble frame. Secure frame using rivets and customer supplied rivet gun. B Light trap aluminum angle (sides) (2) Light trap aluminum angle (top/bottom) (2) 2. Attach aluminum angles to top and bottom frame panels first using rivets. NOTE: Aluminum angle for top and bottom panels will extend beyond panel edges as shown. A A 3. Next attach aluminium angle to side panels in place using rivets. 4. Attach light trap to building. 2 3 B 1 ATTENTION: Bottom aluminum angle includes a grommet hole for the cable to pass through for motorized shutter applications. Install 113392 grommet into hole. Does not apply if light trap is not installed over a motorized shutter assembly. 6 115426_115427_115428

Assembly Instructions: 115426, 115427, & 115428 (including A kits) 3 INSTALL MOTORIZED SHUTTER & LIGHT TRAP Complete Procedure 3 to install shutter assembly and light trap. Consult instructions that shipped with the shutter and shutter motor to install those items. See alternate location on next page for shutter installation before following the manufacture's instructions. Complete these steps: 1. Measure shutter. Frame rough opening accordingly. Tek screws are to secure to metal framing. Contact your sales representative to purchase different fasteners for framing that is wood or other material, or purchase fasteners locally. 2. Install end wall cladding and cut opening in cladding for shutter installation. Tek Screws FA4484B 3. Apply a bead of sealant around shutter opening. See dashed line above. View as seen from outside the building. 4. Standing outside the building, set shutter in place and secure shutter to metal frame using FA4484B Tek screws. 115426_115427_115428 7

3 INSTALL Assembly Instructions: 115426, 115427, & 115428 (including A kits) MOTORIZED SHUTTER & LIGHT TRAP continued 8. Attach cable to shutter as described in the instruction included with shutter and shutter motor. 5. Carefully lift assembled light trap up to shutter position and align light trap with shutter. 6. While holding light trap against frame, have an assistant test the operation of the shutters to ensure they do not contact light trap vanes. ATTENTION: If shutter contacts light trap vanes, mark light trap mounting flange position on frame and add frame material to jamb out the opening to allow for proper shutter operation. 7. Attach shutter motor and pulley to frame below shutter assembly. Construct additional framing as needed to provide a mounting surface. Light Trap Jamb Material (if needed) AS5075 Pulley Cable Shutter Motor Shutter as seen from inside building. ATTENTION: Use cable included with shutter and blackout kit to judge motor and pulley positions on frame. Ensure all pulleys align with center arm of shutter where cable attaches. Ensure shutter operates smoothly and does not bind or contact frame. Secure pulley and motor using FA4482B Tek screws for metal frame. ATTENTION: Allow free end of cable to hang freely from shutter. Do not connect to shutter motor at this time. View shows shutter as seen standing inside the building looking at shutter. 8 115426_115427_115428

Assembly Instructions: 115426, 115427, & 115428 (including A kits) 3 INSTALL MOTORIZED SHUTTER & LIGHT TRAP continued 9. Take light trap and locate center along bottom. Drill a 7/16" hole through bottom panel for shutter cable. Use hole in mounting angle as a guide. 11. With assistance, carefully lift light trap assembly up to frame where it will be attached. 12. Have an assistant thread the free end of shutter cable through grommet. 13. Center light trap over frame. Use a level if needed to ensure light trap is level and square on frame and over shutter assembly. Top Top Attach this side to frame. Level Mounting Flange Center Line Light Trap Bottom Bottom Side View As seen from inside building. ATTENTION: See the diagram for your light trap for part details to determine the bottom of the light trap. Technical diagrams for light traps begin on page 11 of this guide. 10. Install 113392 grommet in hole drilled in previous step. 113392 Grommet 14. While light trap is held in place, have an assistant pull shutter cable to ensure shutters operate freely. Adjust light trap position if binding occurs. 115426_115427_115428 9

Assembly Instructions: 115426, 115427, & 115428 (including A kits) 3 INSTALL MOTORIZED SHUTTER & LIGHT TRAP continued ATTENTION: All electrical circuits shall be designed in accordance with local and regional building codes and standards. 15. After confirming smooth shutter operation, secure light trap to frame using FA4482B Tek screws. 16. Contact an electrician to connect shutter motor to power. FA4482B Light Trap As seen from inside building. As seen from inside building. Cable Cable Electrical Conduit NOTE: Number of Tek screws used depends on light trap size. 17. Use instructions sent with shutter motor to connect cable to motor. 18. Test shutter and shutter motor operation. Shutters should open and close easily and without binding. 19. Read the care and maintenance information on page 2. 10 115426_115427_115428

116140A Breathable Wall Light Trap with Frame (2' x 2') Assembled 28 5 8 " ATTENTION: To assemble this item only, complete Procedures 1 & 2. 113392 28 3 8 " 116141 116166 FRONT VIEW 11 3 16 " 113450 116144 116139 116142 116143 RIGHT VIEW 115426_115427_115428 11

116146A Breathable Wall Light Trap with Frame (3' x 3') Assembled 40 11 16 " ATTENTION: To assemble this item only, complete Procedures 1 & 2. 40 3 8 " 116167 113392 116147 FRONT VIEW 116148 11 3 16 " 113439 116139 116150 116149 RIGHT VIEW 12 115426_115427_115428

116151A Breathable Wall Light Trap with Frame (4' x 4') Assembled 52 11 16 " ATTENTION: To assemble this item only, complete Procedures 1 & 2. 52 3 8 " 116168 113392 116152 FRONT VIEW 113423 116155 11 3 16 " 116139 116153 116154 RIGHT VIEW 115426_115427_115428 13