Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building

Similar documents
We have you walking on air

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Recapture Capacity for Existing. and Airflow Optimization

SMART VENTILATION MANAGEMENT: CHANGING THE WAY WE THINK ABOUT VENTILATION

Thermal management. Thermal management

Efficiency of Data Center cooling

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

APRIL 2010 VOL. 13 NO. 4. Modular Cleanrooms for Business Startups and New Product Development

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

raise your expectations

HVAC Project. Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations

Design and Installation Challenges: Aisle Containment Systems

MSYS 4480 AC Systems Winter 2015

Close Coupled Cooling for Datacentres

Samuel Tepp Engineering Seminar Topics

HOW TO SELECT A CLEANROOM: MODULAR CLEANROOMS FOR NEW BUSINESSES, NEW PRODUCT DEVELOPMENT

White Paper Technology Infrastructure Upgrade Boosts Performance of Older Buildings In today s environment, older buildings need to support ongoing fu

Casino Gaming Environments

Commercial Controls. Advanced control for saving time and money

Access Floors. Nu-Life. Renovation & Modernization of Existing Workspace. Access Flooring to the Power of

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Reducing Energy Consumption with

Underfloor Air Distribution Design Guide File Type

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering

Application of TileFlow to Improve Cooling in a Data Center

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Building Loads and Dedicated Outdoor Air Systems

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Achieving Operational Excellence

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Reducing Data Center Cooling Costs through Airflow Containment

Optimizing Cooling Performance Of a Data Center

Ten Cooling Solutions to Support High- Density Server Deployment

Building Openings Smoke Testing vs CFD Modelling

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

System Controls Suggested Specification

Energy Efficient Commercial Building Tax Deduction Internal Revenue Code Section 179D

Data Center Airflow Management Basics: Comparing Containment Systems

Underfloor v. Overhead Cabling

Data Center Optimization Services. Maximize Your Data Center

Application of Green Technology For Data Centre

M+W Group s Visionary Delta Datacenter

MECHANICAL CALCULATIONS USING REVIT

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

MEASURE MONITOR UNDERSTAND

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Taking The Heat Off University of East Anglia Data Centre

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES

B E I N Y O U R E L E M E N T

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Effectiveness and Implementation of Modular Containment in Existing Data Centers

Ceiling diffusers - visible

TRACE 700 Learning Series Module 2: Navigation

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

How to Increase Data Center Efficiency

DEOS Building Automation. Future can be that simple.

Automation Monitoring Control. EDN 2010 Hot 100

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre

Next Generation Cooling

New Wisconsin Energy Code: What it Means for Me?

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Energy Efficient Data Centers

Impact of Air Containment Systems

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!

A Green Approach. Thermal

Green Data Centers A Guideline

Overcoming the Challenges of Server Virtualisation

APC InfraStruXure Solution Overview

CFD validation of the thermal comfort in a room using draft rates

Innovative Data Center Energy Efficiency Solutions

Rethinking Datacenter Cooling

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Google s Green Data Centers: Network POP Case Study

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

Temperature monitoring and CFD Analysis of Data Centre

Operation Manual. rev Charge then remove battery when stored for more than 1 week. Flow Finder MK2. Powered Flow Hood

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Consultancy along with installation for Air Conditioning System and expertise in Clean Room Systems.

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

WIRELESS ENVIRONMENTAL MONITORS

Cabinet Level Containment. IsoFlo Cabinet. Isolated Airfl ow Cabinet for Raised Floor Data Centers

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Doing More with Less: Maintaining, Operating, and Improving your BMS. Bernard Keister, V PE Senior Engineer Guttmann & Blaevoet Consulting Engineers

Newark, Delaware Architectural Engineering Senior Thesis Portfolio

College Statement and Statistics Campus Site Map Five-Year Capital Plan Request FY through FY

LCP Hybrid Efficient performance with heat pipe technology

Total Modular Data Centre Solutions

A separate CRAC Unit plant zone was created between the external façade and the technical space.

Pramod Mandagere Prof. David Du Sandeep Uttamchandani (IBM Almaden)

Data Centre Products. Airflow Management Solutions

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Transcription:

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building We shape our buildings and then our buildings shape us Winston Churchill, 1943 EurIng Pantelis Kouzis BEng (Hons) General Manager International Operations EKA Group

Why Under Floor HVAC

Our World is Changing! Our Business Environment is Developing! The way we do business is different! Our buildings need to change in order to be ready for what is coming next 70 s 90 s 80 s

Requirements in modern commercial buildings: Short Construction Time Friendly Working Environment Technology Implementations

Basic Characteristics for a modern commercial building: Modularity Accessibility Flexibility Adaptability Standardised elements / parts. Ease of reaching the building services and systems for maintenance and/or replacement The ability to permit growth, moves and changes The ease of implementing these growth, moves and changes

Life * Cycle Cost of a Building Operational 50% * 40 years Modifications 25% Construction 11% Source: AT&T Global Private Systems SYSTIMAX Structure Cabling Systems Financing 14% The way in which you construct your building today will determine in the end how much it will cost to live in it.

Total * Investment in Office Building Furniture 1% M&E Services 4% Construction 5% Maintenance 2% Land 1% Cleaning 1% * Over a period of 40 years Salaries 86% Source: Davis Langdon & Everest Consultants

What is Modular, Accessible, Flexible, Adaptable? Raised Access Floor

Don t Just use the Raised Floor but Utilize it!

Don t Just use the Raised Floor Don t Just use the Raised Floor Utilize it!

This is NOT proper Utilization of the raised access floor! MEP Services are Accessible, but are they Flexible and Adaptable?

Energizing the Office

Raised Floor can look Fabulous!

Raised Floor can look Fabulous!

Raised Floor can look Fabulous!

Raised Floor can look Fabulous!

Raised Floor can look Fabulous!

Raised Floor can look Fabulous!

What HVAC system should be used to retain: Modularity Accessibility Adaptability Flexibility

Overhead HVAC Systems Video

Ceiling based facilities can not respond to modern and future building (unknown) requirements Current construction methods are under scrutiny by leading developers and companies because the costs are too high, AET FLEXIBLE programme SPACE time is too long and methods are wasteful

Modern Workplaces based on Open Plan Arrangements

Underfloor HVAC System Under floor HVAC systems provide improved flexibility for building services, allowing for fast and inexpensive reconfigurations and accommodate the high churn rates of the modern workplace

Floor Supply Ceiling Return

Floor Supply Floor Return Room Temp 23 Set Pt 22 Scheduled supply air temperature 14-27 Deg C Room temp 25 Set Pt 25 Master Slave Room Temp 22 Set Pt 21 Fresh Air at 18-24 deg C

Underfloor HVAC System A design concept which needs: No horizontal piping No ducting No false ceiling (Conditional) No pressure balancing No wall thermostat.and offers Shorter installation time More flexibility Better comfort Much cheaper reconfiguration time User friendly operation Easier maintenance and cleaning

Underfloor HVAC with Passive Diffusers Limited or No Local Control Highly Pressurized Plenums / Possible Noise Problems Possible Air Leakages Cold Feet Syndrome Hot Spots inside the Plenum of the Raised Floor Limitations in Air Throw and Diffusers Air Flow

Underfloor HVAC with Passive Diffusers

Underfloor HVAC with Passive VAV Boxes Highly Pressurized Plenums / Possible Noise Problems Possible Air Leakages Cold Feet Syndrome Hot Spots inside the Plenum of the Raised Floor Limitations in Air Throw and Diffusers Air Flow Very High Raised Access Floor Plenums

CFD Model for underfloor plenum air path

CFD Model for Temperature Simulation

Underfloor HVAC with Active (Fan Assisted) VAV Boxes Very Low Raised Floor (30cm) Throw of Air at High Level (1.7m 2m) Low Pressure Plenum Good Control over Pressure Good Control over Air Speed and Air Volume Possibilities in BMS Interfacing Communication between Floor and AHU

Floor Terminal Unit Active VAV Box 260mm Supply Grille Supply Air Temp Sensor Under floor

Floor Terminal Unit Active VAV Box Electronic controller with LCD Screen

Floor Terminal Unit CFD Model

Floor Terminal Unit CFD Model Air Velocity Slide

Floor Terminal Unit CFD Model Temperature Slide

CFD Model Carbon Dioxide Slide

Modeling of Costs and Net Present Values: Data courtesy of The British Council for Offices, Arup Associates & BAA

14 th April 2006

14 th April 2006

24 th August 2006

6 th December 2006

4 th January 2007 Eurobank Cards HQ Building Athens (Greece) 10,000m 2 of High Tech Offices completed in just 8 months

Conclusions: Long and Short Term Benefits Height Savings (Up to 30cm per Floor) Shorter Building Program (Up to 30%) Initial Building Cost Savings (between 5% - 7%) Reduced Life Cycle Running & Maintenance Costs (up to 20% Energy Savings) Improved Thermal Comfort Lower Reconfiguration Costs Shorter Reconfiguration Time Needed Improved Ventilation Efficiency & IAQ Points towards LEED accreditation

Thank you! Thank you