75F Smart VAV with Reheat

Similar documents
FCU-4 FAN COIL CONTROLLER

Temperature controller Ducted systems

Tstat8. Bacnet Thermostat

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

The Bard BrightStat Room Controllers

FCU-4 FAN COIL CONTROLLER

Operation Guide CT32 ENGLISH

Room controller STRA-17

Smart Equipment Controls (SEC)

clarity 3 Programmable Controller

System Controls Suggested Specification

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

M1000 INTELLIGENT ZONE CONTROL SYSTEM

DataNab it8: Intelligent Communicating Thermostat

Pre-programmed room controller with display and communication

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

SEZ7000 Series. Wireless Commercial Zoning System

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Specification Sheet For electronically commutated motors

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Field selectable application type and room module series, via dip-switches on controller

Underfloor Controllers

FXVMA Variable Air Volume (VAV) Box Controller

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

VZ7000 Series. BACnet Commercial Zoning System

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

ECON-ZIP-BASE. ZIP Economizer Base Module

USER S MANUAL. DAS-G01 The Power of Tomorrow

Andover ContinuumTM. b3850 Series Terminal Controllers

Control systems. Efficient room control

Siemens BACnet Programmable TEC Constant Volume

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

BA/BS4S Temperature Sensor Installation & Operating Instructions

IQ-MP Gateway. Version apr Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel :

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Description. descriptors, makes set-up and monitoring very user friendly.

SE8300 Room Controller

Communicative controller for VAV systems

Connect with Comfort. Phone not included. Smart Wi-Fi Universal Thermostats

Product Data. SYSTXCCITW01---A, SYSTXCCITC01---A & SYSTXCCITN01---A Infinityr Touch Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR TOUCH CONTROL

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Fast Route to Reliable Energy Savings ZIP Economizer

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

FUME HOOD CONTROLLER (FHC)

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

Building Energy Management Training Systems

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

BACnet Terminal Box (VAV) Controller

Installation and Operation Instructions

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Technical data sheet

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Temperature controller Multi-zone ducted systems

Pre-programmed room controller with display and communication

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

AIAS. Technical description

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Daikin HVAC Controls Guide Specification

SE7600E Series Application Guide

Siemens BACnet Programmable TEC Unit Conditioner Controller

Connect hydronics and Building Automation and save time in every phase

TAC Xenta 121-FC Programmable Fan Coil Application

Product Data. SYSTXCCUIZ01-- B Infinityt Zone Control. INFINITY t ZONE CONTROL

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Siemens BACnet VAV Actuator

Andover ContinuumTM Infinet II

MOD-RI Room Interface Modules with Modbus

THERMOSTATS & CONTROLLERS

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Key Features and Benefits

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

CDD4 Duct Carbon Dioxide Transmitter

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Datasheet. ECB-203 Series. 1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview

Temperature Controller

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers

Installation & User Manual

TEC Unit Conditioner Controller

HLS34 Modbus FCU/VAV Controllers installation instructions

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

BACnet. b3810 Series Local Controllers

Wireless Supervisory Controls for HVAC Energy Management

WIRELESS ENVIRONMENTAL MONITORS

Daikin HVAC Controls Guide Specification

TAC Xenta 121-HP Programmable Heat Pump Application

AHU Solutions Programmable controllers for air handling units

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

Transcription:

A unique system-wide approach to maximizing performance PRODUCT OVERVIEW The wireless control solution reduces install cost, improves energy efficiency, and introduces remote control and diagnostic capabilities to Variable Air Volume (VAV) zone control systems. Typical VAV with Reheat systems have inherent inefficiencies when first cooling to 55 degrees and then heating the same air year-round. Rigid outside air temperature reset schedules don t sense and manage to actual demand. 75F offers a smart, cost-effective solution for controlling these systems, improving efficiency and performance in new or existing buildings. 75F adds sensors to measure and record upstream and downstream airflow temperatures, while our smart controls modulate the damper position and reheat controls (available for both electric and water heating coils). This allows for fine-tuning adjustments and remote monitoring of controls performance, as well as preventative diagnostics and insights on your reheat unit performance. 75F takes over the morning warm-up routine and the outside air temperature reset schedule and replaces them with a dynamic system-wide sensing and proactive control to meet actual loads. The Smart VAV with Reheat control kit includes controller, sensors and sensor cables. It is compatible with 0-10V, 2-10V, 10-0V and 02-2V modulating actuators Updated 2/09/2018

A unique system-wide approach to maximizing performance COMPONENTS OF SMART VAV 75 Facilisight & Occupant App 75 Central Control Unit 75F Smart Node 75F Remote Temperature & Humidity Sensor ACI A/CP-DO-4 Bullet Thermistor PRODUCT OPTIONS Standard / Alternate Standard Product Description Components P/N Black Cap RTH local sensing with Smart Node for Smart VAV with Reheat Smart Node, 20 cable, 2 airflow sensors, RTH (black) 3020-BL Alternate White Cap RTH local sensing with Smart Node for Smart VAV with Reheat Smart Node, 20 cable, 2 airflow sensors, RTH (white) 3020-WH Alternate Flush Mount RTH local sensing with Smart Node for Smart VAV with Reheat Smart Node, 20 cable, 2 airflow sensors, RTH (flush mount) 3020-FM Alternate Ceiling CTH local sensing Smart Node for Smart VAV with Reheat Smart Node, 20 cable, 2 airflow sensors, RTH (ceiling) 3020-CL Alternate ITM local control with Smart Node for Smart VAV with Reheat Smart Node, 20 cable, 2 airflow sensors, ITM 3025 Updated 2/09/2018

A unique system-wide approach to maximizing performance LOGISTICAL DIAGRAM For comprehensive wiring, see installation guide Updated 2/09/2018

75F Facilisight SOFTWARE PRODUCT OVERVIEW Facilisight, a suite of web and mobile apps, allows for remote monitoring and temperature control of your smart HVAC, lighting and energy system. Simply oversee and manage the 75F system across all your sites. Performance evaluation provides insight into equipment performance, to predict failures and verify service actions. Live heat maps provide instant information into how your building absorbs and distributes thermal loads and energy performance. Click on any zone to see detailed analysis specific to that space and associated equipment. FEATURES Compatible with major web browsers, iphone, ipad and Android View all buildings in real-time with Google Map integration Heat maps provide instant insight into how your buildings absorb and distribute thermal loads throughout the day; drill in for zone performance Policy editor allows you to push complex schedules to hundreds of locations with a single click Scheduling feature allows you to mark holidays and implement energy savings across your portfolio Google Calendar integration to automatically schedule temperature and lighting changes Mange user settings including editing profiles, passwords and editing or removing additional users Building performance metrics, now including integrated Arc score APPLICATIONS Facilisight is included standard in all our applications, including: 75F Dynamic Airflow Balancing 75F Outside Air Optimization 75F Hydronic Controls 75F Single Stage Equipment Controls 75F Advanced Lighting

75F Facilisight SOFTWARE The home page allows you to take in a big picture view of your entire portfolio of buildings, looking at current energy savings, alerts and more. Schedule your system down to the minute and add vacations to let your system know when the building won t be occupied. Google Calendar integration allows dynamic schedule feed. Energy usage analysis provides insight into equipment performance, which can help predict failures and verify service actions. The heat map view gives at-a-glance color-coded status relative to setpoint, drill-down detail for each zone and corresponding equipment (e.g. RTU), plus an energy dashboard.

75F Central Control Unit (CCU) PRODUCT OVERVIEW The 75F Central Control Unit (CCU) acts as a wall-mounted aggregation gateway for 75F s wireless terminal equipment modules in a building. The CCU consists of a tablet running Android and a Control Mote that provides inputs & outputs for connecting to central plant equipment. FEATURES Works with single and multi-stage systems, heat pump systems, fan coil units, air handlers, variable flow hydronic systems and other systems Control up to 24 terminal equipment modules per Central Control Unit Auto changeover Proactive, predictive control in conjunction with 75F cloud servers; able to run program offline Intuitive Android-based user interface 75F FACILISIGHT Facilisight, our suite of web and mobile apps, allows for remote monitoring and control of your smart HVAC or lighting system. Oversee and manage the 75F system across all your sites. Compatible with iphone, ipad, Android phones and all major web browsers. User app enables occupants to personalize temperature and lighting. APPLICATIONS Software-defined hardware enables dynamic application assignment: 75F Dynamic Airflow Balancing 75F Outside Air Optimization 75F Hydronic Controls 75F Single Stage Equipment Controls 75F Advanced Lighting Additional applications can use IFTT logic for processes, with software-defined configurations.

75F Central Control Unit (CCU) CCU ASSEMBLY DIMENSIONS (mm) 209.3 209.3 209.3 133.3 133.3 133.3 37.3 INCLUDED (1) Central Control Unit (CCU) (1) Remote Temperature Sensor (RTS) SPECIFICATIONS GENERAL HVAC controls 37.3 18 & 20 RTS cables 24V ac power supply Mounting Hardware 2 stage heating & cooling, 2 stage fan, 0-10V modulating output for VFD, heating/cooling hydronics, 1 humidifier 37.3 RTS Sensor Mounting Microprocessor Screen Termination Dimensions Operating temp. ELECTRICAL Supply Battery Inputs (2) #8 screws Quad core tegra 3 @1.2GHz 7.02 1280x800 (216 PPI) Screw-type terminal blocks (16 AWG max) 114 mm x 200 mm (4.5 x 7.9 ); 37.3 mm from wall 0-50 C (32-122 F) 24V ac/dc or 5V dc. Consumption: 5 VA (typ), 10 VA (max) 4,325 mah 7 hours active display; weeks in standby (2) 0-10V analog inputs, (2) 10k thermistor inputs Outputs (4) 0-10V or 4-20V ma analog outputs, (8) 110V ac, 24V dc/1a relays COMMUNICATIONS Wi-Fi Wi-Fi to connect to internet Bluetooth Mesh Wired Used for pairing devices (e.g. 75F Smart Node equipment control) IEEE 802.15.4-compliant; used for device communications on mesh network 3 wire communication to backup RTH

75F Smart Node LEFT RIGHT TOP BOTTOM PRODUCT OVERVIEW The 75F Smart Node is a revolutionary equipment controller with flexible software-defined configurations which can control a range of equipment from zone dampers, to reheats, to economizer controls. It operates off 24V ac or dc and is designed for daisy chain power, making installation of your power bus simple and fast. The Smart Node is designed with multiple inputs and outputs, plus 900MHz and Bluetooth wireless communications, for a range of sensing measurements and controls capabilities. Hardware defined by software means improvements are included in every software update. FEATURES OLED display with software-defined relevance Backlit text indicates which inputs/outputs are enabled for confidence in installation Robust construction with machined metal studs for mounting Wireless mesh networking 75F FACILISIGHT Facilisight, our suite of web and mobile apps, allows for remote monitoring and control of your smart HVAC or lighting system. Oversee and manage the 75F system across all your sites. Compatible with iphone, ipad, Android phones and all major web browsers. User app enables occupants to personalize temperature and lighting. APPLICATIONS Software-defined hardware enables dynamic application assignment: 75F Dynamic Airflow Balancing 75F Outside Air Optimization 75F Hydronic Controls 75F Single Stage Equipment Controls 75F Advanced Lighting Additional applications can use IFTT logic for processes, with software-defined configurations.

I 75F Smart Node DIMENSIONS (mm) 27.89 27.89 INCLUDED IN DEFAULT CONFIGURATION 136.14 136.14 (1) Smart Node (1) Remote Temperature Humidity Sensor (RTH) (1) 20 cable T EMP E RA T UR E A ND H UM I D T Y S E NS OR RTH Sensor 150.14 150.14 1 1 2 2 SPECIFICATIONS GENERAL Screen 1Termination 1 OLED WAGO2061 series poke-in connectors. 3 and 4-wire Molex connectors. RJ-45 for dampers. 2 2 3 3 Dimensions 114 mm x 200 mm (4.5 x 7.9 ) ELECTRICAL Supply 24V ac/dc Inputs (2) 10k thermistor inputs, (2) 0-10V dc analog inputs Outputs (2) 0-10V dc analog outputs, (2) dry contact relays rated at 110V ac, 24V dc, (2) RJ-45 for Smart Dampers COMMUNICATIONS Bluetooth Used during commissioning and wireless triangulation Mesh IEEE 802.15.4-compliant; used for device communication on mesh network Wired 4 wire RS-485 interface, 3 pin connector for RTS. BACnet support coming soon.

75F Remote Temperature & Humidity Sensor (RTH) PRODUCT OVERVIEW The 75F Remote Temperature and Humidity Sensor (RTH) offers high-precision measurement pre-calibrated from the factory for measuring comfort factors of temperature and humidity. The RTH is easily mounted on a wall by a single toggle bolt. A Remote Temperature and Humidity (RTH) sensor paired with a 75F Smart Node results in a clean aesthetic in your space while minimizing installation times. The RTH provides accurate temperature and humidity values from your space and the Smart Node reports these values to the 75F Central Control Unit (CCU) for zone monitoring and control. FEATURES Accurate temperature readings Accurate humidity readings Sleek design, low impact aesthetics 75F FACILISIGHT Facilisight, our suite of web and mobile apps, allows for remote monitoring and control of your smart HVAC or lighting system. Oversee and manage the 75F system across all your sites. Compatible with iphone, ipad, Android phones and all major web browsers. User app enables occupants to personalize temperature and lighting. APPLICATIONS Software-defined hardware enables dynamic application assignment: 75F Dynamic Airflow Balancing 75F Outside Air Optimization 75F Hydronic Controls 75F Single Stage Equipment Controls 75F Advanced Lighting Additional applications can use IFTT logic for processes, with software-defined configurations.

75F Remote Temperature & Humidity Sensor (RTH) DIMENSIONS (mm) 59.6 64.5 64.5 T EMP E RA T UR E A ND H UM I D I T Y S E NS OR 28.8 28.8 INCLUDED (1) Remote Temperature Humidity Sensor (RTH) 5.6 5.6 SPECIFICATIONS GENERAL Mounting Termination (1) Toggle bolt, requires 1 hole in drywall 3 pin connector Dimensions 59.6mm circumference, 5.6mm surface depth, 64.5mm total length, 28.8mm backplate diameter Operating temp. Operating Environment: 0 F 122 F Accuracy Humidity (typical +/- 2% RH), Temperature (typical +/- 0.2C) ELECTRICAL Power 6.5V dc provided by Smart Node via 3 pin connectors COMMUNICATIONS Wired 3 wire interface for power and communication; proprietary 1 wire protocol to communicate with a master device RTH (R

A/CP-DO-4 PRODUCT OVERVIEW 10K Ohms @ 77 Deg F (25 Deg C) Type II Thermistor. The standard duct without box configuration has a mounting flange for quick installation and etched-teflon leads. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration. Additional options include: plenum rated cable and quick connects for direct termination to male VAV-Controller inputs. ACI duct temperaure sensors are designed for HVAC, Building Automation, and light industrial sysetms. Specific applications include: zone control, air handling units, and temperature monitoring. Version 1.0 updated 10/22/2017