MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

Similar documents
LED. Sign Module. Assembly Manual

Meter Enclosure and Equipment Standards

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Instruction Manual: IM E

FT & RT Test Switches

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

COMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21

Zenith Series DPB Distributed Power Busway

Installation Notes TII Model 341 Protector

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Installing a Power over Ethernet injector

ASCO SERIES 300 Manual Transfer Switch Solutions

Power-Style QED-2, Series 2 Low Voltage Switchboards

RS3000 SERIES BILL ACCEPTORS

Haworth Power Technical Sheets January 2018

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

National Light Sources Pty Ltd Electrical Accessories - Date 8th April, Coombes Drive, Penrith, NSW, 2750 Australia

SECTION SWITCHBOARDS

The Leviton Load Center THE FUTURE MADE CURRENT

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION WIRING DEVICES

EPIC Circular Connectors CIRCON M23 Series

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Powering innovation. Powering efficiency. Powering home

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

H704-42(H)(E), H704-42/1(H)(E)

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

MLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529

Installation & Operation Manual

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Self Contained - Non-Jaw Clamping Lever Bypass

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Quick Start Guide TS 870 ATS

Self Contained - Non Lever Bypass

nls Product List 1st February, 2014 Tel: Fax: Coombes Drive, Penrith, NSW, 2750 Australia

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Summary of shell housings and accessories Shell housing A Shell housing D EMC housing

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

SECTION DISCONNECT SWITCHES

Compact, Low Profile High Rendering, 100% Diffusion

Series Amp Quick Connect Input and Output Power Panels

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

WINSTA. Full Line Catalog 2008/2009

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Posi-Lok Plugs and Panels

Carbon Monoxide (CO) Gas Detection and Control System

FDS / FDS-R / FDS-PS

Mounting Accessory Guide

Illinois and Northwest Indiana Metering Equipment

The Leviton Load Center THE FUTURE MADE CURRENT

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Overvoltage Protection

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

page 28 page 30 page 30 page 31

revos revos Industrial Multipole Connectors 3 48 pole in metal housing Program for Tough Tasks

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Bulletin 800Z Zero-Force Touch Buttons

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

MICHIGAN DEPARTMENT OF TRANSPORTATION

Advantages of a Full Featured 700 Series Relay

Multi-Point Gas Detection and Control System

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

imac Intel 21.5" Retina 4K Display Power Supply Replacement

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Zenith Series DPB. Distributed Power Busway

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

PANELITE ENCLOSURE LIGHTS OVERVIEW

EcoFlex LED Neon Manual

FCC17 Series FILTERED STACKED D-SUB CONNECTORS

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

Installing the DX LCD Display

62GB. Amphenol Series 62GB. Applications. Features

M215 Microinverter Installation Planning

sonnen Installation Practical

Terminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks

10 Pg C1 - C-30.qxp 6/9/ :43 AM Page C1. BELL Weatherproof Boxes, Covers, and Lighting

Telephony Multi-Taps. 9000T-TP Series

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Universal Keying Adapter 3+

INSTALLATION INSTRUCTIONS

For (2) Single Receptacles: dia. Hole Standard Depth

Linearray PD Retrofit Kit

Transcription:

Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management

CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs for #12-2 wire Specifications UL Recognized Marwell Housing. 600 VAC Rated. Aluminum Pole Bracket. Jaw lugs rated for # 12-2 cable or 10-32 Screw terminals optional. Strain relief option chart: PG-21 PG-16 PG-13.5 PG-9.545 -.709 inches.428 -.546 inches.270 -.470 inches.187 -.300 inches Ground Lug Select the Strain Relief Ordering Instructions: Model SP-2125-6-L-BKT (shown) - Available in 4, 5 and 6 jaw models. - Lugs standard, screw terminals optional. - Available with or without strain relief. - Specify strain relief size if needed. - Hole optional for up to 1 inch conduit. - Pole mount bracket may be deleted. - Top or Bottom conduit holes.

CAPACITOR MONITOR AMI Capacitor Monitor Fixed or Switched Capacitor Banks AMI monitors can be used on all Fixed or Switched Capacitor Banks. The internal CT reads the current on the neutral bus of the CAP bank. Capacitor monitor has a built in 100:5 amp CT. This CT will be shorted by an internal switch when meter is removed. The AMI meter stores the hourly reading and transmits the data daily to a database. The AMI Monitor has a 3 4 plastic tube running inside the enclosure that goes thru the 100/5 amp ct. Tube for neutral sensing wire. 100/5 CT SHORTING SWITCH FOR CT

Temporary Service Adapter for 4/0 Cable Designed for one, two, or three cables - size 4/0 This special adapter will safely connect either one or two number 4/0 cables to the line side jaws of a meter socket. A 4/0 neutral may also be connected. Plugs are provided for the unused cable entrance holes. The adapter may be used as either a source or load device by lifting the existing service cables from the socket lugs. Adapter Specifications.! - Patented jaw for 200 Amp continuous duty. - All components UL LISTED or Ordering Instructions: UL Recognized. Conductor size - Weatherproof 6 X 8 X 5 inch deep enclosure. - Marwell 4-Bolt 1.5 x 2 non-metallic coupler. - Sealable and Lockable cover. - Supplied with two non-metallic tamper resistant plugs to close the unused cable entrance holes. Model 1800-TSA-4/0 4/0 for 4/0 cable 3/0 for 3/0 cable 2/0 for 2/0 cable Meter socket type 1000 for Ring style 1800 for Ringless style

QUICK-SET GENERATOR ADAPTER! This new version of the Marwell generator adapter is designed to be hard wired to a standby generator. Roll out the generator with adapter already connected, pull the meter, clip the neutral, and plug-in the adapter. Just two minutes and you are safely connected. Complete isolation, no back feed to the utility power grid. May be sealed with a standard meter ring. The quick way to connect a temporary generator MARWELL QUICK-SET! OPTIONS: 120V or 240V Wire size and length to specifications Wire end termination per customer Blunt cut wire end (None) Pre-stripped Twist-lock plug Straight blade plug Use the GEN-SET version for meter storage ORDERING INFORMATION: Contact Marwell and specify you requirements for either the QUICK-SET or GEN-SET adapter. Specify: Voltage Amp rating Wire length Wire end connection type GEN-SET with meter storage

Temporary Service Adapters LINE / LOAD 1800-1-TSA-2/0 Source Side 1800-1-TSA-2/0 Load Side Adapter Rated For 200 Amps MAX 160 Amps Continuous Maximum Conductor Size 2/0 AWG Line Side, 1/0 AWG Neutral Lug Adapter Rated For 160 Amps Max 135 Amps Continuous Maximum Conductor Size 2/0 # 2 AWG Neutral Lead With Heavy Duty Terminal End Hub Size 2 Polycarbonate Combined Load Rating Of Adapters Installed As A Pair 200 Amps Max, 160 Amps Cont. Line Side, 1/0 AWG Neutral Lug #2 AWG Neutral Lead With Heavy Duty Terminal End Hub Size 2 Polycarbonate Line Side Stabs Of Adapter Are Isolated From Metered Side Of Adapter. Line Side Only

TSA TEMPORARY SERVICE ADAPTERS Specifications * TSA-LINE Rated for 200 Amp continuous combined load. * TSA-LOAD Rated for 100 Amp continuous standard. Higher rating optional. * Each meter registers only one house. * Modified UL Listed adapter with UL Recognized components throughout. * Will not back feed the faulted cable. Temporary repair of failed underground. A large southern utility came to us for a heavy duty set of Temporary Service Adapters, something to help them connect jumper cables to a meter socket in the event of a failed service at a residence. The jumper cable is actually a length of #2 Triplex. The night emergency crew normally runs it on the ground to bring power into a home until a day crew can get back and make a proper repair. The adapters needed to be rugged for repeated reuse and the source adapter must be able to handle the high current load of two houses. The Marwell TSA is up to the task. The TSA-LOAD is attached to the end of the cable and inserted in the meter socket of the dark house. The TSA-LINE is attached to the other end of the cable and inserted in a neighbors house that has power. The meter in each adapter measures only the consumption of its respective home. Ordering Instructions: 1000-TSA-LINE Source adapter for ring style systems, 200 Amp continuous combined load 1000-TSA-LOAD Load adapter for ring style systems. 1800-TSA-LINE Source adapter for ringless systems, 200 Amp continuous combined load 1800-TSA-LOAD Load adapter for ringless systems.

Transformer Load Management Adapter and Energy Diversion Mount the Marwell TLM Adapter at the transformer site and install Smart Meter. Use Smart Meter to collect and transmit data from transformer site. Marwell Corporation pole mounted Transformer Load Management adapter is available in two different current ratings in self-contained units. Marwell Part # TLM-2s-200A Rated 200 Amps Continuous, 600V rated. Marwell Part # TLM-2s-400A Rated 320 Amps Continuous, 600V