AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting. Siemens AB. Version 5.0 A Security Products

Similar documents
ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Digital Keypad Introduction

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

User Manual. Printer P-52RUE

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Waterproof. Keypad/Reader/Controller

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

Digital input modules

USER MANUAL. RC-43T Remote Controller MODEL: P/N: Rev 3

english Thanks for choosing the Xbox GB Hard Drive. The Xbox GB Hard Drive lets you save games, save music and create

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

584 5WG AB_1 DELTA

Display Panel BAT 100 LSN. en Operation Guide

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

To connect the AC adapter:

MULTI-MONITOR CONTROLLER USER MANUAL

CHSM2210-B CHSM2211-B Medium Camera Housing with Integrated Bracket

User Manual. PCKeypad Wireless Keypad

Single Door Standalone Access Control User Manual

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

HD40H(X) Performance Series Camera. User Guide

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

Room unit with PPS2 interface

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation Manual Premier 8XP. Issue 4

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Optional Accessories 6 2

Installation instructions Inclination sensor EC2019 EC / / 2013

Quick Installation Guide

GV-Card Reader. User s Manual

ST-HDC2FD QUICK START GUIDE. Or contact technical

Nokia Bluetooth Headset BH /1

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Instruction Chain drive series HCV

CM-110SK Standalone Keypad Installation Instructions

Version-E Manual PR1a. Photocell. Manual. Page 1

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Installing Sentor. Hardware Installation

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

IRIS516. User Guide. Compact Marine PTZ Controller

WIRED REMOTE INSTALLATION GUIDE

W3-M. Metal waterproof standalone access control/reader. User Manual

BC Digital Keypad. User Manual

TruVision TVC-SD Series Smoke Detector Camera Installation Manual

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Power supply module, bus connection module

TXM1.8RB. TX-I/O Blinds module

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

INSTALLATION INSTRUCTIONS

User Manual MagniLink One

Installation manual EVA Start and Protected

Installation Manual BAK02

VZ-TVI-B3040MZVF 3MP Motorized VF EXIR Bullet Camera

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

GV-IPCam H.264. Hardware Manual. Vandal Proof IP Dome Target Vandal Proof IP Dome

Dell Inspiron N5110 Service Manual

XENO 8. User & Installation Manual.

Nokia Bluetooth Headset BH /1

TruVision IP Thermal Camera Installation Guide

Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer.

Dell XPS 14z Owner s Manual

Hinged safety switches, Palladio line

INSTALLATION/USER MANUAL

TURBO HD TVI Bullet & Turret Camera

USER MANUAL MODEL: TDPB-2V1AD Dual square table box with HDMI, VGA, 3.5mm audio, and RJ45 inputs

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Replacing the Gateway M405 Keyboard

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

W3-H Waterproof Keypad/Reader/Controller

Resistance measuring module

Operating Instructions VEGAMET 381

Super universal modules

F1000 User's Manual. (Version: V1.01)

Replacement Instructions

ABB Junction boxes Top solutions for surface mounting

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

Nokia Bluetooth Headset BH-218. Issue 1.0

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Installation Guide DEVIlink CC Central Controller

Camera A14 and A34 Dome Camera

Room unit with PPS2 interface

Always there to help you. Register your product and get support at BT3500. Question? Contact Philips.

Quartz. Digital. Dual switch. Installation guide. Quartz Digital Dual switch installation instructions Page 1

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Network Dome Camera Quick Start Guide

HiPath optipoint 500 economy optipoint 500 basic optipoint 500 standard optipoint 500 advance. User Guide

Hardware Manual RM Display 2501 S01..S04

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Replacing the Gateway M275 Keyboard

VR 80 Remote Control Device

Transcription:

AR10S-MF AR11S-MF AR40S-MF AR41S-MF Installation manual for mounting and connecting Version.0 06.09.2013 Security Products

Copyright Copyright Technical specifications and availability subject to change without notice. Copyright We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. Edition: 06.09.2013 Document ID: 2

Table of Contents 1 Introduction... 4 2 Technical data... 3 Safety regulations... 6 3.1 Standards and guidelines... 6 4 Reader components... 67 Mounting and connecting... 69.1 Surface mounted reader... 610.2 Surface mounted reader with cables fed from outside... 611.3 Back box mounted reader... 613.4 Back box mounted reader with adapter plate... 614. Connecting the cables... 61.6 Disassembling the reader... 617 6 Default settings... 618 7 Connecting card reader to SiPass integrated... 619 8 Disposal... 720 3

1 Introduction 1 Introduction The AR10S-MF, AR11S-MF, AR40S-MF and AR41S-MF are a series of executively designed card readers for modern security. They are made of hardwearing materials and will endure most weather conditions. The readers are easy to mount and connect, and can be mounted on a flat surface or partly inside a back box. They can be cleaned with most kind of domestic detergents. All readers have a multicolor light frame. The AR40S-MF and AR41S-MF also have a keypad and a high contrast display. 4

Technical data 2 2 Technical data AR10S-MF Mifare card reader standard AR11S-MF Mifare card reader standard incl. UK adapter plate and extension cable Protocol OSDP OSDP Interface to controller RS48 RS48 Operating voltage 8. 30.0 VDC 8. 30.0 VDC Power consumption DC 12V 43mA Peak 168mA DC 24V 26mA Peak 100mA Tamper protection Yes Yes AR40S-MF Mifare card reader standard with keypad and display AR41S-MF Mifare card reader standard with keypad and display standard incl. UK adapter plate and extension cable DC 12V 60mA Peak 220mA DC 24V 40mA Peak 12mA Card technology Mifare Mifare Card compatibility Mifare Classic Mifare Plus (UID only) Mifare DESfire EV1 Mifare Classic Mifare Plus (UID only) Mifare DESfire EV1 Reading distance Up to 6 cm Up to 6 cm Indicators 3 x LED (red/yellow/green) 1 x Buzzer Multicolor light frame 3 x LED (red/yellow/green) 1 x Buzzer Multicolor light frame Keypad No Yes Display No Yes, graphic monochrome OLED Operating temperature -40 to + * -40 to + * IP rating IP** IP** IK class 08 08 Housing Zinc casted metal bezel with polycarbonate plastic front Zinc casted metal bezel with polycarbonate plastic front Color Black, matt chrome Black, matt chrome Dimensions (W x H x D) Approvals Surface mounted: 8 x 114 x 22 Back box mounted: 8 x 114 x 14 CE according to R&TT and EMC Directives * Only applicable for surface mounted readers. Back box mounted readers are specified from -10 to +. ** Only applicable for surface mounted readers. Back box mounted readers are specified to IP3X. Surface mounted: 8 x 114 x 22 Back box mounted: 8 x 114 x 14 CE according to R&TT and EMC Directives

3 Safety regulations Standards and guidelines 3 Safety regulations General Follow all warnings and instructions marked on the device. Keep this document for reference purposes. Please take into account any additional country-specific, local laws, safety standards or regulations concerning installation, operation and disposal of the product. Liability claim Do not make any changes or modifications to the device. Use only spare parts and accessories that have been approved by the manufacturer. 3.1 Standards and guidelines European directives Siemens Security Products hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC on Electromagnetic Compatibility (EMC). The EC Declaration of Conformity is available from your Siemens sales office or: Englundavägen 7 SE-171 24 Solna Sweden 6

Reader components 4 4 Reader components 1 2 4 3 6 7 8 9 1 Hinge 6 Screw for removal from wall tamper protection 2 Base 7 Front 3 Cord gasket 8 Back box plate 4 Knock outs x 4 9 Adapter plate (AR11S-MF, AR41S-MF) Tamper base 7

4 Reader components 1 2 3 4 1 Screws for back box plate 2 Connector 3 Opening tool please note that this is a symbolic depiction of the opening tool 4 Extension cable (AR11S-MF, AR41S-MF) 8

Mounting and connecting Standards and guidelines Mounting and connecting The reader enables two different mounting alternatives: surface mounted and back box mounted. Those come in two different varieties, depending on how the wires are fed or which kind of back box is used. The reader is delivered with components to support the two mounting alternatives. Please note that the alternatives only require some of the different components. Before mounting the reader, identify the parts which are needed for the appropriate alternative. Please refer to respective page for: Surface mounted reader [ 10] the reader is mounted on the base, which first is fastened on a wall. Surface mounted reader with cables fed from outside [ 11] the reader is mounted on the base and the cables are connected via one of the knock outs. Back box mounted reader [ 13] the reader is partly mounted inside a back box in a wall. The two extra screws prevent the reader from rotating. Back box mounted reader with adapter plate [ 14] The reader is partly mounted inside a square back box and an adapter plate is used to widen the area for mounting the reader. For connecting the cables to the reader, please refer to: Connecting the cables [ 1]. 9

Mounting and connecting Surface mounted reader.1 Surface mounted reader Use drills and screws appropriate for the surface which the reader is to be mounted upon. The surface should be flat to ensure a close fit. To attach the base to the wall: 1. Make a small hole in the base gasket. The cables will be pushed through this hole. 2. Attach the base to the wall with three screws: one in the middle at the top of the base, and two in the corners at the bottom of the base. 3. In case that the removal from wall tamper protection is required, fix the screw into the hole under the tamper base. Ensure to not use excessive force since this can damage the tamper base. 4. Continue to follow the instructions Connecting the cables [ 1]. 10

Mounting and connecting Surface mounted reader with cables fed from outside.2 Surface mounted reader with cables fed from outside Should the cables be fed from outside: 1. Remove the cord gasket from the base. 2. Identify which of the knock outs the cables should be fed through. 3. Insert the flat head screw driver in the pocket of the knock out. 4. Hammer the screw driver handle. This will create enough pressure to crack the exact area of the base which will release the knock out.. Tilt the knock out with the screwdriver. 1 x. mm 11

Mounting and connecting Surface mounted reader with cables fed from outside 6. Pull the knock out away from the base. 7. Attach the base to the wall with three screws: one in the middle at the top of the base and two in corners at the bottom of the base. 8. In case that the removal from wall tamper protection is required, fix the screw into the hole under the tamper base. Ensure to not use excessive force since this can damage the tamper base. 9. Feed the cables through the opening and reinsert the cord gasket. Proceed to the instructions for Connecting the cables [ 1]. It is recommended to seal the gap which the knock out creates. Please note that a reader with a removed knock out is not IP. 12

Mounting and connecting Back box mounted reader.3 Back box mounted reader The reader is mounted on a back box which is attached with two extra screws. 1. Mount the back box plate on to the back box. 2. Attach the extra screws at the lower part of the back box plate in order to prevent rotation. Use only the screws included in the packet for the lower part of the base since those ensure that the reader front will fit perfectly to be securely fitted over the back box. 3. Continue to follow the instructions for Connecting the reader [ 1]. 13

Mounting and connecting Back box mounted reader with adapter plate.4 Back box mounted reader with adapter plate For certain square back boxes, please use the adapter plate in order to widen the area for mounting: 1. Place the back box plate on top of the adapter plate. 2. Attach the base and adapter plate with two screws on the side. 3. Continue to follow the instructions for Connecting the cables [ 1]. The adapter plate is to be used for square back boxes which measure 70 mm x 70 mm. The adapter plate is used for common UK square boxes. 14

Mounting and connecting Connecting the cables. Connecting the cables The cables are connected on the respective indicators. Should an extension cable be used, the cables are already attached to the connector. 1. Attach the cables according to the respective indicators on the connector and the base: A B - +. Please note that A and B are used for communication, and that and + are used for power. Further information is found in Connecting card reader to SiPass integrated [ 19]. 2. Snap the connector in place. 3. Push the cables back. 4. On the backside of the front there is an EOL jumper used for RS48 bus termination. By default the reader has the termination ON and acts as the last reader on the bus. However, if it is an intermediate reader on the bus, the jumper must be removed or placed in OFF position.. Place the front of the reader with an angle to the hinges at the top of the base. 1

Mounting and connecting Connecting the cables 6. Fold the front down until the snap lock confirms a secure attachment. 16

Mounting and connecting Disassembling the reader.6 Disassembling the reader Should the reader need to be taken apart: 1. Carefully insert the opening tool in the slot between the base and the front. 2. Push gently and lift the front of the base. To remove the connector: 1. Insert the opening tool as indicated on the picture. 2. Push down gently and tilt the connector away from the base. 17

6 Default settings 6 Default settings Time-out for configuration card Time-out for display messages Activation time-out Hold-off time for card read Repetition of card Character set Min background illumination 12 3 seconds 7 seconds 30 seconds 100 milliseconds Inactive Latin1 Max background illumination 2 Bus address Off-line indication Backlight Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 Light frame follows LED indicators Reading MIFARE Classic Reading MIFARE Plus SL1 SL3 Reading MIFARE DESFire EV1 0 (Up to eight are supported) Yes Always active (Never and Timed activation are possible) Red and green, yellow (not active) UID UID UID The card readers are delivered in this default mode. This mode can be altered with the Configuration Card Creation Tool (3CT), which enables for required settings to be used for the card readers. For further information, please contact the supplier of this reader. This product uses FreeRTOS V7.0.1. FreeRTOS software can be downloaded at www.freertos.org or retrieved from Siemens Security Products 18

Connecting card reader to SiPass integrated 7 7 Connecting card reader to SiPass integrated The connection between a card reader and a Reader Interface Module (RIM) is as follows: RIM (DRI/ERI) ARxx-MF 12V + 0V - Tx/+ A Rx/- B 19

8 Disposal 8 Disposal All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. 20

Scale 1:1 Units: mm 114 8 42.2 12 184 86 12. 16 14 42. 60 9

Issued by Infrastructure & Cities Sector Security Products International Headquarters Englundavägen 7 SE-171 41 Solna Tel. +46 8 629 0300 www.siemens.com/securityproducts 2013 Copyright Technical specifications and availability subject to change without notice. Document ID Edition 06.09.2013