ID Title Description of the restriction Solutions for the restriction

Similar documents
SIEMENS. General conditions and function limitations, notes for configuration and operation

Siemens Automation Products

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction


SINAMICS S120 Family New functions in firmware V4.6 and STARTER V4.3 SP2

Introduction to the TIA Portal V13, S7-1500, and Startdrive

SIMOTION V4.1 SP2 HF3/HF4

Welcome Guideline D435 training case with SIMOTION 4.1 SP1

Service & Support. How do I configure extended PROFIsafe on the CU240E-2?

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Service & Support. How can the Safety Functions of SINAMICS S120 be activated in an existing STEP 7 Project? Technology CPU.


SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

Guide to updating firmware from versions V4.3.x through V4.6.x to V4.7.x for SINAMICS S120 with CU310-2 and CU320-2

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

Welcome. Guideline SIMOTION D4x5-2. Training Case with SIMOTION V4.4

Transform your Drive Safety Capability with Innovative Market Driven Technology Presented by Craig Nelson Manufacturing in America March 14-15, 2018

Description of the Simotion D4xx Firmware update

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

Description and Tutorial for. SIMOCRANE Drive-Based Technology V1.0 SP1 HF2. with Sinamics CU 310-2

SINAMICS G120/G120D/G120C/G120P/G110M

TIA Portal Workshop. Unrestricted. Siemens AG All rights reserved.

CANopen with SINAMICS G120. SINAMICS G120 with speed setpoint and CAopen interface. FAQ November Service & Support. Answers for industry.

Totally Integrated Automation Application Notes

Drive-based Synchronism

FAQ about Drive Technology

Display of SINAMICS Error Messages in Runtime Professional


SIMOCRANE Drive-Based Sway Control V1.0 SP2

Connecting a PC Station to an S using OPC

What's new? New functions for. SIMOTION V5.2 SP1 Edition 04/2018 siemens.com/simotion

SIMOCRANE Drive-Based Sway Control V1.0 SP1 HF1 Siemens AG All Rights Reserved. siemens.com/cranes

SINUMERIK. SINUMERIK 840D sl SINUMERIK STEP 7 Toolbox V14 SP1. Preface. Product information. Configuring the NCU. Programming the PLC 3

SINAMICS G120 Family New functions in firmware V4.6 and STARTER V4.3 SP2

Spring Training Atlanta, GA


Position Control with SIMATIC S and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET. Application description 03/2016


SIMOTION. New functions of version V4.1 SP2

Siemens Hardware SIMOTION. Motion Control Getting Started with SIMOTION SCOUT TIA

Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via Object Manager) SIMATIC & SINAMICS

Cut down your costs, increase your productions efficiently with the knowledge of PLC s Siemens technology. SITRAIN TM THAILAND Page 1 of 13

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SINAMICS. Safety. SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters. Function Manual

Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via GSD file) SIMATIC & SINAMICS S

SINAMICS S120. Getting Started with the. Drive Concept 1. Prerequisites 2. Creating the Drive Project OFFLINE 3

Hydraulic Axis with SIMOTION D410 (Use of the Onboard Encoder Interface without Power Unit PM340)

How to Easily Implement Siemens Motion Control Solution in the Real World? Presented by Craig Nelson and Kevin Wu Manufacturing in America March

Features SIMOTION V4.1 SP2

Applications & Tools. SINAMICS S120: Control of the Safety Integrated Basic Functions via onboard terminals SINAMICS S120

Service & Support. Which dependencies exist between the safety functions of the SINAMICS S120 drive system? Technology CPU.

SINAMICS G120 Firmware Version V4.7 SP6 HF1. Unrestricted / Siemens AG All Rights Reserved.

How to read or write multiple parameters using FB286

Drives Based Safety Integrated

Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via Object Manager) SIMATIC & SINAMICS

Applications & Tools. Application to support the acceptance test of the Safety Integrated Functions of SINAMICS G120 SINAMICS G120

Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2 SINAMICS

SINAMICS S120. Getting Started 01/2013 SINAMICS

Applications & Tools. Controlling Safety Integrated Extended Functions and transferring the F-DIs of the CU310-2 PN via PROFIsafe with PROFINET

Drive System Application

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

Changeover SINAMICS CU240E to CU240E-2 (as from Firmware V4.4) SINAMICS G120. FAQ October Service & Support. Answers for industry.

Bumpless Media Redundancy with PROFINET IRT (MRPD) SIMOTION & SINAMICS. Application description July Applications & Tools. Answers for industry.

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

SINAMICS POLYGON. Master-value-dependent characteristic functionality. Function Manual

Application for Process Automation

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

Display of SINAMICS Fault Messages in WinCC V7.4

SINAMICS V-ASSISTANT Online Help SINAMICS. SINAMICS V90 SINAMICS V-ASSISTANT Online Help. Preface. Fundamental safety instructions

CMMT-AS-PN controlled by SINAPOS functions block with Siemens S controller

ServoChoke /Encoder Configuration Using a Siemens Drive

Applications & Tools. Control of the Safety Integrated Extended Functions of the SINAMICS S110 via the fail-safe inputs of the CU305 SINAMICS S110

SINAMICS S120 Safety Integrated Extended Functions

IMA with DS1H1_ Encoder Configuration Using a Siemens Drive

Accessing SINAMICS parameters via OPC server

Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2 SINAMICS

SIMOTION with SINAMICS S120 Safety Integrated Extended Functions Fail-safe drives connected to SIMOTION D435 Controlled with PROFIsafe via PROFIBUS

Application example 03/2017. PROFINET-system redundancy with SINAMICS drives.

Encoder Configuration for the Positioning Axis Technology Function

SIMATIC S Update to the S System Manual, edition 03/2014 Product Information


SINAMICS. SINAMICS V90 SINAMICS V-ASSISTANT Online Help. Preface. Fundamental safety instructions SINAMICS V-ASSISTANT.

Drive System Application

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

SINAMICS Smart Access

SINAMICS G120 SINAMICS G120C

Configuration of a Measuring Probe on a SINAMICS S120 CU3x0 / CU3x0-2 for Use in a Technology CPU 31xT

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

SINAMICS. SINAMICS V90 SINAMICS V-ASSISTANT Online Help. Preface. Fundamental safety instructions SINAMICS V-ASSISTANT.

Function blocks to control the SINAMICS with SIMATIC S7 in TIA-Portal

SINAMICS V-ASSISTANT Online Help SINAMICS. SINAMICS V90 SINAMICS V-ASSISTANT Online Help. Preface. Safety instructions 1 SINAMICS V-ASSISTANT 2

ST (6ES7132-6FD00-0BB1)

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

TIA Portal V11 Exercises

Applikationen & Tools. SINAMICS S: Positioning an S120 with S7-300/400 via PROFINET in Step7 with Safety Integrated via terminal

Drive System Application

What is your drive? Lead instead of follow? SINAMICS S120: the high-performance drive system.

Partner Product Valve island AirLINE SP Type 8647 for ET 200SP. unrestricted

Applications & Tools. SINAMICS S110 EPOS via FB283. Control via PROFIBUS Safety via F-DI. Application Description February Answers for industry.

SINAMICS Drives Connectivity with EtherNet/IP TM. Networks. Manufacturing in America 02/22-23/2017

Transcription:

SINAMICS Startdrive V15.1 General conditions S120 General conditions and function restrictions as well as notes on configuration and operation. These notes take precedence over statements in other documents. 3148657 Basic positioner calibration The absolute encoder calibration of encoder 2 and encoder 3 cannot be performed via the mask. For encoders 2 and 3, calibration must be initiated using the parameter list (parameter p2507). 1646146 STARTER project upload canceled If an 1FK6 motor is configured with STARTER and loaded to the drive device then the upload with Startdrive is rejected. Configure the 1FK6 motor using Startdrive, and load this to the drive device. 1867374 STARTER project upload rejected If an encoder with DQ interface (10000) is parameterized and loaded to the drive using STARTER, then an upload with Startdrive is only possible if the parameterized encoder is also part of the actual topology. Connect the parameterized encoder or remove the encoder from the target topology in the STARTER project and download again 2675714 1FP1 reluctance motors cannot be used in a project for SINAMICS V4.8 2201921 Standard/ telegram interconnection not protected against changes 1FP1 reluctance motors cannot be commissioned in a project for SINAMICS V4.8. When selecting a standard/ telegram for a SINAMICS drive, certain BICO interconnections are established. Users can subsequently change these interconnections and therefore the telegram. If such a changed configuration is loaded to the drive, then only the original interconnections of the standard/ telegram are active. Upgrading to SINAMICS V5.1. Do not change the interconnections in p2051, p2061, p2080 to p2084 if a standard/ telegram is configured for the drive object. 2587654 Correct diagnosis of power units connected in parallel not possible In the online state, in the device view, diagnostic symbols can be displayed for all drive objects and components. In the case of a parallel connection, the diagnostics status for components connected in parallel is not correct, the status is always "OK". The status of power units connected in parallel must be identified in another way for example, using the message display. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 1/8

2617380 PROFINET topology comparison S120 The online interconnections of the S120 are not detected in the PN topology comparison of the online/offline port interconnections. For G120, the connected devices are automatically detected. 3138276 Upload of S120 configured with STARTER fails An S120 with double Motor Module was configured with STARTER. If an axis of the double Motor Module is deleted and loaded to the device and an attempt is made to upload this project with Startdrive, the result is an "Upload of device aborted" error. 2755473 First download fails sporadically If, in the offline mode, a download is started then sporadically this is unsuccessful. An error message is output stating that the device configuration online and offline would be incompatible; however, this statement is not true. In the PN topology comparison list, for S120, the PROFINET device name must be set and then the connected devices are detected. Please deactivate the axis you do not need STARTER rather than deleting it. The second download attempt functions. Alternatively, you can go online before initiating a download. 2841342 Deactivation of not present device via Openness When you try to change the The corresponding component should be disabled in driveobjectactivation.activationstate of a component that the offline mode rather than in online mode (with does not exist in the online mode, no error message is "DriveFunctionInterface.DriveObjectFunctions.DriveOb returned when you call the Openness function jectactivation.changeactivationstate"). "OnlineDriveFunctionInterface.DriveObjectFunctions.DriveObj ectactivation.changeactivationstate" even though the driveobjectactivation.activationstate remains the same. 3002973 Brake configuration for 1PH8 motors does not work automatically For the 1PH8 series of motors, the brake configuration is not automatically made via the motor configuration. The user must set the brake data manually in the online mode via the parameter list (P550 to P554). general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 2/8

3015586 Motors configured manually with STARTER are not supported in the Startdrive If a motor that was configured manually with STARTER is uploaded using Startdrive, the following error may occur during upload: "The component with article number XMxxx is not supported in the current version". Go online with Startdrive and change the parameter p300 to 0. Then upload and configure the correct motor in the motor properties and then upload it to the drive device. 3728329 "Trace signal" cannot be deleted in online trace In the following scenario, a signal cannot be deleted in the signal list: - Loading a trace to the trace editor that only exists online in the CU - Changing the configuration in the trace editor - Going offline (online connection disconnected) -> A signal cannot be deleted in the signal list Close and reopen the trace editor window 3738768 Upload of a 1LE1 motor canceled If the 1LE1 motor is configured manually and then uploaded, the upload is canceled with a note that the motor is not supported in Startdrive. This affects MLFBs 1LE1001-1AD42-2xxx or 1LE1x01-1AD42-2xxx. Although the 1LE1001-1AD42-2xxx motor exists in the selection list for 1LE1 motors, but an upload is not possible because the selection list is not unique for this motor. In this case, please configure a motor by manually entering data. 3756031 Control panel: Selection in TIA Portal retained 3757142 Line voltage detection with VSM (p3400.5) not automatically active When you use the control panel, the control panel editor and the TIA Portal have stripes in the header. The stripes in the TIA Portal header do not disappear when the control panel is simply closed without handing over master control. When a Smart Line Module in the Chassis format is configured at the S120, a VSM is automatically created but the "Line voltage detection with VSM" is not automatically activated. 1) For security reasons, the control panel should always be deactivated explicitly. 2) The stripes are of no significance in this case; they can be ignored. 3) The stripes disappear when the control panel is activated and deactivated again. Prior to the download, bit P3400.5=1 must be set manually in the parameter list of the Smart Line Module. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 3/8

3769865 TM15: IOs 8... 23 cannot be interconnected via screen forms for S120 3771950 Supplementary telegrams not displayed in "Communication" diagnostics overview for uploaded projects When you try to interconnect IOs 8..23 using screen forms, the interconnection always ends up in IOs 0..7 (modulo 8). When supplementary telegrams (telegram 700, telegram 701) are used in a project that has been upgraded from V15, then these are not displayed in the "Communication" diagnostic view. Change the parameters from IO 8 and higher directly in the parameter list. However, the telegrams still exist; this is merely a display issue. Follow the link in the telegram configuration and go back to the "Communication" diagnostic view. 1946403 Documentation for Drive Library blocks not up-to-date 3077860 Startdrive remains online after connection to S210 interrupted 3130455 Since FW 4.7.9, ZSW1, bit 13 has been assigned a new parameter, which is not in Startdrive. The documentation for the blocks in the Drive Library, To obtain current documentation, please go to SIOS contained in Startdrive in the information system (Help) is not ( Industry Online Support) and review entry ID up-to-date. 109475044. After a physical interruption of the connection between Activate the Startdrive function "Go offline". Startdrive and S210, the Startdrive still shows the device as being online. The offline value for ZSW1 bit 13 in telegram 111 is incorrectly displayed in G120 FW 4.7.9. With FW G120 V4.7 SP9, the content (description) of bit 13 has been changed. 3133891 Hardware detection After uploading the drive via the hardware identification of the PLC, the Power Module is missing in the drive object. 3133969 Hardware detection When adding drives via the hardware identification with firmware < or = 4.7.6, GSDMLs are generated instead of a drive object. 3133973 Hardware detection When adding drives via the hardware identification with firmware 4.7.9, a drive object with firmware 4.7.10 is created. Use FW 4.7.6. After uploading via hardware identification, manually connect the Power Module. Use the function to upload the complete station. Use the function to upload the complete station. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 4/8

3180503 After changing to another screen form, the LED continues to flash. If the user has selected the Flash LED checkbox in the screen form online access in the Online & Diagnostics Editor, and then navigates to another screen form in the Online & Diagnostics Editor and then again returns to the online access screen form, the Flash LED checkbox is deactivated; however, the LED continues flashing on the device and does not stop. 1. The user can navigate back to the online access screen form and then activate the Flash LED checkbox and then deactivate it again so that the LED on the device stops flashing. OR 2. The user can manually set p124 to 0 from the parameter list to stop the LED flashing. 3180567 After changing to another TIA Portal language, the LED continues to flash. The Flash LED checkbox in the screen form online access in the Online & Diagnostics Editor is selected. - The user interface language is changed. - The user navigates back to the online access screen form. - The Flash LED checkbox is deactivated; however, the LED of the device continues flashing and does not stop. 1. The user can navigate back to the online access screen form and then activate the Flash LED checkbox and then deactivate it again so that the LED on the device stops flashing. OR 2. The user can manually set p124 to 0 from the parameter list to stop the LED flashing. 3181227 After closing the TIA Portal, the LED continues to flash. - The Flash LED checkbox is activated in the online access screen form in the Online & Diagnostics Editor. - The TIA Portal closes without deactivating the checkbox. - The LED at the device continues flashing and does not stop. 1. The user can navigate back to the online access screen form and then activate the Flash LED checkbox and then deactivate it again so that the LED on the device stops flashing. OR 2. The user can manually set p124 to 0 from the parameter list to stop the LED flashing. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 5/8

3241686 Profisafe F-DB without prefix results in a PLC compilation error. If, after establishing the connection to the PLC, option "Create driver instance data blocks without prefix" is activated, then the data block names are not unique. This results in a PLC compilation error. 1. Keep option "Create driver instance data blocks without prefix" activated before you establish the connection. Unique names are then generated. 2. Keep option "Create driver instance data blocks without prefix" deactivated after the connection. As a consequence, the name with address/length of the safety telegram is attached. 3719139 Startdrive does not support marking and checking in changes at the server project that were made via local sessions in a multi-user configuration in the SINAMICS drives. In a multi-user environment, the user may mark objects of automation peripheral devices (e.g. program blocks, variable tables, traces etc. of the SIMATIC PLC) added to the TIA Portal in order to update changes to the server project made by several engineers via individual local sessions. Observation: In Startdrive the changes made (e.g. values of a few parameters) at SINAMICS objects should not be marked, so that it is not possible to check-in the changes. This restricts the use of Startdrive with a multi-user setup via local sessions. Workaround: A detailed description of the workaround for the scenario listed above is described at the following link. https://support.industry.siemens.com/cs/document/1 09755940/startdrive-in-tia-portal-v15-with-optionmultiuser-engineering?dti=0&lc=en-WW Comments: However, it is possible to commission drives in a multi-user environment by accessing the drives via the server project view from local sessions, which are only available for one user in a certain instance. 3728293 The online configuration of the G120 CU250S-2 encoder interface results in an error. The first configuration of the encoder G120 CU250S-2 (including the encoder interface) in the online mode via Openness functions perfectly; however, changing a preconfigured encoder interface type results in an error. The encoder interface should be newly configured via Openness in the offline state (instead of online) and downloaded to the drive in order to start the new configuration. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 6/8

3316252 Technology packages are not supported. When uploading to a device with active technology packages (OA), which are not supported by Startdrive, then the OA specific parameters are not uploaded. This can cause the configuration of the technology package involved to be lost when subsequently downloaded. In addition to the free function blocks, Startdrive does not support technology packages there is no workaround/remedy. 3722001 Detection of the device configuration of Double Motor Modules. In the "Detect device configuration" it is possible to configure a Double Motor Module with one axis where one drive object is set to type "Universal (vector)" and one drive object is set to type "High dynamic (servo)". This configuration is rejected if you create the device configuration. Ensure that both axes of a Double Motor Module have the same drive object type. 3750087 Error "Too many online connections". At the same time, the user may have a limited number of connections to the devices. Once this number has been reached, at the next connection request, the user receives an error message that this is not possible: "Too many online connections. Terminate some of the connections and try again". Connections cannot be disconnected by closing the Online & Diagnostics Editor. a) Go offline from the project with the device. b) Restart Startdrive. 3767869 Openness provides incorrect online parameter values after restoring the factory settings. If the user is already online via Openness with an S120/S210 drive, and restores the factory settings, then Openness again specifies the parameter values before restoring them. After restoring the factory settings, the user should go offline and then go online again. 3770985 Pausing via space bar does not work with S120/S210 control panel/obt/motor measurement if a progress dialog is displayed. If a motor connected to S120 or S210 is started from the control panel (including OBT, motor measurement), then the motor should stop when pressing the space bar or lose the focus on Startdrive. If this is not the case, then a progress bar is presently being displayed; for example, as a result of an active upload or station upload of another drive. Do not start any time-consuming task via the TIA Portal while a motor is being operated via Startdrive functions (control panel, One Button Tuning, motor measurement). For the EMERGENCY STOP circuit, ensure that one hardware device is always available. general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 7/8

3735562 When refreshing the download preview dialog box, a DCB extended library that is not available online is not downloaded. If a DCB extension library is to be downloaded, information is displayed in the download preview dialog box. If the user presses F5 in the dialog: Update, the information disappears, the library is not downloaded and DCC is then not executed. Message F51009 is active in SINAMICS. The message disappears after POWER ON; however, DCC is still not executed. Do not press the "Update" button in the download preview. Repeat the download without pressing the "Update" button. 3727680 Uploading and downloading S210 is canceled as a result of an unknown device order number. 3728868 The firmware version is incorrectly displayed in Online & Diagnostics. Firmware V5.1 uses another order number (6SL3210-5HB10-4xxx) than firmware V5.2 (6SL3210-5HB10-4xFx). Updating from V5.1 to V5.2 does not change the order number in the drive. In some instances, the firmware version field in the Editor Online & Diagnostics does not display the correct value. Restoring the factory settings changes the order number to "6SL3210-5HB10-4xFx", as in V5.2. Upload and download with Startdrive is then possible. Execute a new scan via "Update accessible devices". 3804043 Crash in the operator panel with alarms > 32768 A crash can occur in the operator panel if an alarm with a number greater than 32768 is active at the Line Module. - general conditions for SINAMICS Startdrive V15.1 Siemens 2019 unrestricted 8/8