Owner s Hardware Service Manual Frank Control Computer System

Similar documents
INSTALLATION INSTRUCTIONS

MRUC-20 Modul-R CAN Bus Network

Switched Mode Power Supply Operating manual PAP800

PLCIO2 Programmable Logic Controller Updated 3/26/10

SST-2450 Wireless Modem User s Manual

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

Defining the Future in Motion Control

USB-to-I2C. Professional Hardware User s Manual.

1395 Node Adapter Board Troubleshooting

POWERWISE INDAC SETUP MANUAL

Intelligent Devices IDI 1100 Series Technical Manual

EASY21x/23x-EVA. Evaluation Board for EASY21x / EASY23x PLC core. General Description. Ordering Information

I/O EXPANSION MODULES

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

MCU-9201MT22 venetian blind controller

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

Ocean Controls KTA-224 Modbus IO Module

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

Assignment 5. You can configure hardware options by setting jumper on the mainboard. See Figure 2-1 for jumper locations. Set a jumper as follows:

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

Installation and Programming Manual

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

GE Fanuc IC694ALG391. Rx3i PacSystem

Torque Control Verifier

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 658 MULTI-OUTPUT DC/DC CONVERTER POWERED BY 2-CELL, USB OR WALL ADAPTER

1/Build a Mintronics: MintDuino

Moog Components Group Submux1 Manual December 7, 2009

Slick Line Acquisition System Manual

Modem Installation and Networking Instructions

270 MHz Control Modules

LVX Control Unit. Features:

CS485. User s Manual. Version ZYPEX, Inc.

Manual 601: : USB/RS232. Specifications. Contents. Options

I/O Expansion Module Installation & Reference

I / O Expander. Instrument for torque control ASL 11/17

T1K MODBUS Base Controller Specifications

EP-ELVCTL Elevator Control (NION-16C48M)

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E

USER MANUAL FOR FIOA-0402-U-16

USB-L111. USB-L111 User Manual TPM. Version: V M05. To properly use the product, read this manual thoroughly is necessary.

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Overview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Accessories IC690ACC900

PLA User. WARNING: read connection information(p5) before connecting PL controllers to the PLA

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

Cheetah16/32/64 Setup Guide

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

BMS: Installation Manual v2.x - Documentation

Relay Contact Output Modules

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

ACR8000 Hardware Manual

This Datasheet is for the IC693ALG390. Memory Backup and Backup Battery.

OPERATION MANUAL. Decision Group Inc. SMARTLAB USB 16 CHANNELS RELAY OUTPUT 16 CHANNELS PHOTO ISOLATOR INPUT BOARD

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

CHAPTER Wi r i n g NOTICE:

EISA Series Desktop. Computer Specifications. Processor Board. Main System Board. Mass Storage Bays. EISA configuration.

NetBiter I/O Extender User Manual

mbc082 Bus Converter

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

MOD-MUX MODBUS TCP I/O PRODUCTS

Warranty. Warning. Copyright. Contact Us

Vector Drive - Troubleshooting Guide

Computer Maintenance. PC Disassembly and Reassembly. Copyright Texas Education Agency, All rights reserved.

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

EnerSure Installation Guide

Installation Instructions

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

USB-to-I2C. Ultra Hardware User s Manual.

Mini4 Data Mux User s Manual. ( xxx) And. Troubleshooting Guide

1. CP430, CP470, CP474, CP770 and CP774

DREAM 2 WIRED RTU SYSTEM GUIDE

PAC BI-DP BIM and 8701-CA-BI Carrier

IST ULTRASTAB Power Supply for high precision transducers

Air Hockey v7.0 Controller PCB Air Hockey 10v Transformer

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

icex-cmtm General specs and Installation guide

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

KNJN I2C bus development boards

5504 Thermocouple Analog Input Module

GE Fanuc IC694ALG221. Rx3i PacSystem

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

I2C-AO112DIx I2C-Bus 4-20mA Analog Output Boards Din-Rail supports

PROFIBUS DP/CAN Gateway PCA-100. User Manual

the Interactive Catalog

PWR-I/O-DB Power and I/O Daughterboard (#28301)

Two Door Controller GEN-045

Transcription:

Owner s Hardware Service Manual Frank Control Computer System Revision 0105

ABOUT THIS MANUAL This section describes the contents of this manual and how to use this manual effectively. It was designed for a wide range of different types of users. Manual Overview This manual is divided into the following sections: Section 1.0 Introduction product features, list of all components. Section 2.0 Component Description describes the use of each component along with a picture. Section 3.0 Technical Theory explains the general electronic theory and appropriate connections for each component. Section 4.0 Troubleshooting How To Use This Manual Your Frank Control Computer System Operating manual is both a reference book and a tutorial of how to solve some common problems. 2

TABLE OF CONTENTS 1.0 INTRODUCTION 4 1.1 Features 4 1.2 Main Components 4 2.0 COMPONENT DESCRIPTION 6 3.0 TECHNICAL THEORY 10 3.1 FC Card Cage 10 3.2 Data-Acquisition Temperature System 11 4.0 TROUBLESHOOTING 14 4.1 General Information 14 4.2 Temperature System 14 3

I N T R O D U C T I O N Thank you for purchasing a Frank Control Computer System. You made an excellent choice for performance, reliability, and value. Your Frank Control Computer System uses a high performance Z80 CPU and 8085 CPU. An 8051 micro controller is used to read in all the digital temperatures; freeing time for the main processors to do more important things. The Frank Control Computer System talks to a PC to allow for a userfriendly control interface. It also talks to an Allen Bradley PLC that handles all the I/O s. Here are some of the professional features of your new Frank Control Computer System. Features Up to 48 Isolated Digital Temperatures per Kiln Easy Temperature Probe Replacement Control up to 5 Kilns per System Triple Processor Computer System Battery Back Up and Real Time Clock Power Fail Monitor and Watchdog Timer RS232 communication to Allen Bradley PLC -80 inputs, 32 outputs, and 32 analog outputs RS232 communication to PC Note: Each cabinet is customize depending on the kilns design Main Components Note: Components included depend on the Kilns needs. All components and connections are defined in the Operating instructions of this manual. 110-Volt / 220-Volt Power Supply Board Programmable Data-Acquisition Temperature Board (DAQT) Bulb Connection Board Eprom Card CPU Card 4

Power Fail Card Battery Back-Up Card Digital Temperature Card (DIGT) Digital to Analog Board Isolation Board ATX Power Supply Hammond 166F16 Curtis Line Filter 5

C O M P O N E N T D E S C R I P T I O N This section has been designed to assist the user in understanding how the Frank Control Computer System functions. It shows a picture of each component with a description about its use. 110-Volt / 220-Volt Power Supply Board supplies 12V AC to the regulator on the Data- Acquisition board. Note: See Installation Instructions for 220-Volt operation. Figure 1 Power Supply Board WARNING!!! Power Supply is shipped as a default of 110-Volt operation Programmable DAQT Board holds the firmware that determines the functions of the Data Acquisition System. Figure 2 Data-Acquisition Temperature Board Bulb Connection Board allows connection of digital devices. Figure 3 Digital Connection Board 6

40-Pin Bus Cable connects the Bulb Connection board to the DAQT board. Figure 4 40-Pin Bus Cable 6 Pin Serial Communication Connector allows connection to the serial communication on the DAQT Board. Figure 5 Serial Communication Connector Eprom Card holds the main program that runs the kilns. Figure 6 Eprom Card SIO Card converts parallel data from the STD bus to serial data. The ports the Frank Control Computer System uses to talk with the PC and PLC. Figure 7 SIO Card 7

CPU Card The Motherboard that controls all the other cards. Runs the program in the Eprom Card. Figure 8 CPU Card Power Fail Card Monitors the power line. Figure 9 Power Fail Card Battery Back-Up Card Holds the RAM that the Frank Control Computer System uses. A real time clock chip allows the computer to keep track of time. Contains a battery to hold memory in the RAM on a power failure. Figure 10 Battery Back-Up Card 8

DIGT Card Holds the program that allows communication through the Isolation board to the DAQT boards. Figure 11 Digital Temperature Card DAC Board Converts serial data from the DAQT board to eight 4-20mA analog output channels. Figure 12 Digital to Analog Board Isolation Board Optically isolates the Digital Temperature card from the Data- Acquisition Temperature System. Figure 13 Isolation Board ATX Power Supply Supplies power to the Card Cage. See Appendix for details on connections. Hammond 166F16 Supplies 12v power to the Isolation board and AC to J4 on the PFA card. Curtis Line Filter Filters the AC line before the ATX Power Supply and the Hammond 166F16 transformer. 10-Pin Bus Cable Connects the DIGT card to the Isolation board. 9

T E C H N I C A L T H E O R Y This section has been broken down into two sub sections explaining in detail each component in the Frank Control Computer System. FC Card Cage This sub section explains the Technical Operation of all the STD cards in the Frank Control Computer System. Figure 14 Most common card configuration Eprom Card This card has six 64k EPROM chips witch hold the main program that runs the kiln. The card comes pre loaded with a program and can only be changed if sent into Frank Controls Ltd. It is the brains behind the operation of the kiln. SIO Card This card allows the Frank Control Computer System to communicate with the Desktop PC and PLC. The top channel (Channel 1) is the port for communicating to the PC. The bottom channel (Channel 2) is the port for communicating to the PLC. CPU Card This card is the Z80 CPU. It runs the program in the EPROM chips. Battery Back-Up Card This card holds the Random Access Memory and the Real Time Clock. It has a battery so when the Frank Control Computer System is powered down the data in the RAM is not lost. There is also an on board charger for the (3v) NICAD battery. Power Fail Card This card monitors Power Failure. If the Frank Control Computer System has power the LED will glow red. If there is a loss of power or the card is not working, the LED will go out. Only the top of the two connectors is used for normal operation. 10

Digital Temperature Card 8085 microprocessor controlled onboard 8KB EPROM & 2K RAM. This card holds the program for communicating to the Data-Acquisition boards. It is connected to the Isolation board through a 14-pin bus cable. Isolation Board This board has six optically isolated Digital I/Os and one non-isolated channel. The first five Digital I/Os connect to the DAQT boards; one channel for each kiln up to five kilns. The sixth channel is used for resetting the DAQT boards. The non-isolated channel connects to the outside Digital Bulb. The 14-pin bus cable connects to the DIGT card. It is powered by 12 VDC from the Hammond 166F6 transformer. Data Acquisition Temperature System This sub section explains the Technical Operation of all the boards in the Data- Acquisition Temperature System. Figure 15 Data-Acquisition System Mounted on Din rail Power Supply Board 110-Volts is connected to the terminal labeled 110V AC. L1 is HOT and L2 is NEUTRAL. If 220-Volt supply is required, contact for further information on jumpering the Power Supply board for 220-Volt operation. The three-pin connector on the cable shown in Figure 1 is connected to J6 on the Data-Acquisition Board. Data-Acquisition Temperature Board (DAQT) This board can operate in four different modes. Board modes must be programmed at Mode 1 (Normal Operation) Mode 2 (Master Operation) Mode 3 (Slave Operation) Mode 4 (PLC Operation) Normal Operation (Mode 1) J2 is connected to the Frank Control Isolation board. J6 is the socket for the power supply board connector. 11

J7 has no connection. J1 Digital Bulbs Connection socket is used to connect to the Bulb Connection board. Master Operation (Mode 2) J2 is connected to the Frank Control Isolation board. J6 is the socket for the power supply board connector. J7 is connected to J7 on the Data-Acquisition board programmed as a Slave. J1 Digital Bulbs Connection socket is used to connect to the Bulb Connection board. Slave Operation (Mode 3) J2 is connected to the Digital to Analog board(s) if available. J6 is the socket for the power supply board connector. J7 is connected to J7 on the Data-Acquisition board programmed as a Master. J1 Digital Bulbs Connection socket is used to connect to the Bulb Connection board. PLC Operation (Mode 4) J2 is connected to the Digital to Analog board(s) if available. J6 is the socket for the power supply board connector. J7 is connected to the RS232 comport on the PLC. J1 Digital Bulbs Connection socket is used to connect to the Bulb Connection board. Table 2 Isolation board and DAQT board connections Isolation Board Terminals DAQT Terminals EG XGND D1 EXT-Data +5 EXT +5 Table 3 Digital to Analog board and DAQT board connections DAC 1 Terminals DAC 2 Terminals Data-Acquisition Terminals GND GND XGND SCL SCL S-CLOCK SDT SDT S-DATA SYNC NC EXT +5 NC SYNC EXT-DATA Bulb Connection Board J1 40-Pin bus socket is used to connect to the Data-Acquisition board. The most common bulb configuration is shown below. No matter how many Dry Bulbs your kiln has the Wet Bulbs will always be the last two bulbs. 12

Table 3 Digital Bulb Connections Terminal Label Device D1 Dry Bulb 1 D2 Dry Bulb 2 D3 Dry Bulb 3 D4 Dry Bulb 4 D5 Dry Bulb 5 D6 Dry Bulb 6 D7 Dry Bulb 7 D8 Dry Bulb 8 D9 Dry Bulb 9 D10 Dry Bulb 10 D11 Dry Bulb 11 D12 Dry Bulb 12 D13 Wet Bulb 1 D14 Wet Bulb 2 D15 Spare D16 Spare Digital to Analog Board (DAC) The DAC boards have eight 4-20mA channels. They communicate only with a DAQT programmed in either Slave or PLC operation. The six-pin connector is connected to the six-pin connector on the DAQT. See table 3. They are powered by 24 VDC. If the +24 OK and +5 OK lights are on they have power. Each of the eight analog output channels has a led when on the channel is not connected or has a problem. Digital Bulb The Digital Bulb has three connections: +5VDC Power (White Wire) Data (Red Wire) Common (Black Wire) 13

T R O U B L E S H O O T I N G This section was included to help the maintenance troubleshoot common problems that could occur while operating the Frank Control Computer System. It should be used to recognize a problem, and troubleshoot to fix the problem. General Information Test a probe to see if it is good or bad Disconnect the outside temperature probe from the isolation board terminal block T4. Connect the probe you want to check in place of the outside probe. Go to the computer and look at the outside temperature to see if it is working. It could take up to 30 seconds to for the computer to receive a new outside temperature. Temperature System Some Temperature Values may read 265,266,267,268, or 269 These are error codes letting you know there is a problem with reading the temperature value from the probe. Regardless of the actual code value, the troubleshooting is the same. DAQT Temperature System (Green Data-Acquisition System) The Digital Bulbs are connected to a DAQT system. RECOGNIZING THE PROBLEM A single bulb shows an error code consistently - Bad/broken bulb, or broken wire connection to the bulb - The corresponding channel on the Bulb Connection board is open. A single bulb shows an error code intermittently - Problem with an intermittent open connection to that bulb - Bulb failure at certain temperatures All the bulb show an error code - The DAQT board has lost power - The Isolation board has lost power - Communication between the DAQT board and Isolation board is lost 14

TROUBLESHOOTING THE PROBLEM Measure the Voltage In operation the DC voltage measured at the Isolation board for each DAQT board is shown below. This will help to indicate if there is a short between the +5VDC or Data line to Common. See table 2 in the Technical Theory Section of this manual for terminal block descriptions. If some bulbs are working still then test these voltages for each bulb. Between Common & +5VDC Between Common & Data constant 5.0VDC pulsating 2.8-5.0VDC If there is a short in the communication do the following steps: 1. Disconnect the wires to the Isolation board & measure the voltages at the Isolation board to determine if the problem is at the Isolation board. 2. Disconnect the wires to the DAQT board & measure the voltages at the DAQT board to determine if the problem is at the DAQT board. If there is a short in the bulb itself: 1. Disconnect the Red and White wires on the shorted bulb. Connect that bulb in place of a bulb that is working and measuring the voltages again to see if the bulb is still shorted. This will determine if the bulb is shorted or the channel on Bulb Connection board is shorted. Keep in mind it could be the wire that is shorted. 2. To test the bulb one at a time connect it in place of the outside temperature and see if it works. If there is no short but the bulb doesn t work: 1. Disconnect the wires from the Bulb Connection board of the bulb that doesn t work. 2. Connect a bulb that you know works into the channel of the Bulb Connection board that doesn t seem to work. If it works then the bulb that was taken out must be bad (open). If it doesn t work then the channel on the Bulb Connection board must be open. Testing the Bulb Connection boards with an ohm meter Measure the resistance between pin 1 of the 40-pin bus connector and the +5v, Data, and Common on the terminal blocks. Resistance between Red and pin 1 should be about 3000 ohms with the exception D01 will be about 0 ohms. Resistance between White and pin 1 should be about 3000 ohms. Resistance between Black and pin 1 should be about 10000 ohms. Ground Loops / Noise This cause can be difficult to determine without the use of an Oscilloscope. A simple test is to disconnect the Isolation board from the Terminal blocks. Use an Ohmmeter to 15

check for any connection between Chassis ground and the three leads. There should be no connection between Common, Data, or +5V to ground. 16