The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

Similar documents
Switched econnect PDU

Monitored Pro econnect PDU

Key Elements of a Successful Data Center Cabinet Ecosystem

Monitored econnect PDU

CPI Solutions. Protecting your technology investment.

Data Center Solutions Brochure

Frequently Asked Questions

Containment Accessories Floor Mounting Template

POWER DISTRIBUTION UNITS (PDUs)

EF-Series EuroFrame Gen 2 Cabinet System

Data Center Airflow Management Basics: Comparing Containment Systems

Security Infrastructure Protection

Polar PDUs POWER MANAGEMENT

econnect PDU Firmware Upgrader User Manual

CASE STUDY. How the Lego Approach Helped Norway Giant SpareBank 1 Create a Flexible Data Centre. They used what they called the Lego Approach.

Cabinet & Enclosure Systems

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

THE OFFICIAL TRADE JOURNAL OF BICSI

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

Power Distribution Units for Data Centers

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM


Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Power distribution solutions for the ProLiant DL580 G2 server

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

PDU - Overview / Non-Intelligent PDU s

Power Control Socket Strips

Panduit Basic Rack PDU

CPI PowerScope User s Manual Version /

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Server Technology Inc.

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Rack- and Panel-Mount Power Distribution Units (PDUs)

Product Brochure. Eaton epdu G3 Managed

Panduit Basic Rack PDU with Local Meter

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

Auto-Transfer Rack Power Distribution Unit

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Rack- and Panel-Mount Power Distribution Units (PDUs)

Power Distribution. For technical support call Online catalog available at leviton.com 461

Server Specifications

Solutions Guide for Cisco UCS B and C Series Servers

or

Fail-Safe Power Redundancy

PDU Solutions. PDU Solutions

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Server Technology Inc.

Models. Specifications

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Intelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Server Technology, Inc.

Instruction Manual. Rack PDU XP Series. geistglobal.com

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

Installing the Cisco MDS 9020 Fabric Switch

PDU Inspired by Your Data Center. W IEC PDU Series

G5 PDU Installation Guide

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

Power Distribution Units for Data Centers

Product Brochure. Eaton epdu G3 Managed

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

V-Built Custom Preconfigured Solutions

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

The Different Types of AC Power Connectors in North America

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

System Specifications

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

* * Agilent Power Distribution Unit (PDU) Installation Guide

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Inspired by Your Data Center. 1-Phase Intelligent PDU Outlets for 230V

Zonit μats TM Users Guide μats1-lv Version 1.2

E-Series Site Preparation Guide

Power Control and Distribution

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

ipdu Pocket Guide NORTH AMERICA

Deploying High Power to IT Equipment Racks

PDU Branch Current Monitoring Board Installation and Configuration

HYPERFRAME CABINET & ENCLOSURE SOLUTIONS

SmartZone Gateway- Enabled M Series Rack PDU

Managed Rack PDU MPH2 More efficient Simpler Better

APC APPLICATION NOTE #74

Powerware P60/61

Transcription:

WHITE PAPER The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips By David Knapp Product Marketing Manager Chatsworth Products (CPI) Published: January 2019 US & Canada +1-800-834-4969 Toronto, Ontario, Canada +905-850-7770 chatsworth.com chatsworth.com techsupport@chatsworth.com Latin America +52-55-5203-7525 Toll Free within Mexico 01-800-01-7592 chatsworth.com.co chatsworth.com.co Europe +44-1628-524-834 chatsworth.com chatsworth.com Middle East & Africa Dubai, UAE +971-4-2602125 chatsworth.ae chatsworth.ae Asia Pacific +86 21 6880-0266 chatsworth.com.cn chatsworth.com.cn

Chatsworth Products White Paper 2 Introduction Almost every Information and Communications Technologies (ICT) equipment rack used to store compute, storage or network equipment requires a rack-mount Power Distribution Unit (PDU) or power strip (Figure 1) to distribute power to equipment. But, if you are unfamiliar with electrical power distribution systems or even the differences in industry jargon, selecting a PDU or power strip can be challenging. This white paper, by Chatsworth Products (CPI), presents an overview of the basics of selecting PDUs and power strips. It covers the key questions to ask about the site, rack and equipment to help simplify the selection process and quickly identify the right PDU or power strip. It concludes with additional resources that will help you select the right PDU or power strip for your application. Definitions in this White Paper Rack(s) refers to information and communications technologies equipment racks and cabinets any 19 EIA rack-mount support structure for computer servers, data storage or network switches. Rack-mount is used to describe attachment of PDUs or power strips and ICT equipment into data center cabinets and racks. Rack-level is used to describe the placement of PDUs or power strips in both cabinets (cabinet-level) and on racks (rack-level), and the monitoring of conditions inside and immediately around the cabinet or rack. If you are already familiar with selection of PDUs and power strips and just need to find a part number quickly, try the CPI Power Selector www.selectapdu.com. If you would like some help selecting a product or have a technical question, please contact our Technical Support department at techsupport@chatsworth.com. To learn more about PDUs and power strips, download the companion white paper: Additional Considerations When Selecting Power Distribution Units and Power Strips at www.chatsworth.com/white-papers Figure 1: PDUs and Power Strips are used to distribute power into ICT racks and cabinets.

Chatsworth Products White Paper 3 What is the Difference Between a PDU and a Power Strip? At the rack level, the terms PDU and power strip may be used interchangeably. Each manufacturer has a specific product category name: PDU, power strip, Rack Distribution Unit (RDU), Cabinet Distribution Unit (CDU), etc. Within the CPI product line, power strips are lower voltage, with minimal features. CPI power strips include optional surge protection against voltage spikes, which is advised when connecting directly to utility power, a typical requirement in premise equipment rooms. CPI PDUs are higher voltage, with more features. CPI econnect PDUs have robust remote monitoring and control capabilities, which are advised when connecting to conditioned power, and typical in purpose-built data centers and computer rooms. Regardless of slight differences in categorization and product branding, the basics of selecting a PDU or power strip are universal. PDUs and power strips have a power delivery function, decided by input plug, breakers and outlets; and a monitoring function decided by the metering or remote monitoring capabilities. How to Select a PDU or Power Strip At the most basic level, you need to know whether the rack is large enough for a vertical PDU; what type and how many branch power connections are in each rack; how much equipment will be in the rack; and if monitoring is required. Critical decisions when selecting a PDU or Power Strip (see Figure 2) 1. Form Factor use a vertical PDU in a full-height, free-standing rack to maximize possible equipment connections. Use a horizontal PDU in smaller wall-mount racks. 2. Input Plug must match the branch power circuit receptacle at the rack and determines the total amount of power available to equipment in the rack. 3. Outlets match the plug(s) on equipment in the rack. There are two approaches: either select the model with the highest number of outlets used in region, or select the model with the highest number of mixed C13 and C19 outlets. 4. Functionality match the level of monitoring required: no metering, local metering, remote monitoring of the input and breakers, remote monitoring including each outlet, remote control of outlets, or remote monitoring and control of outlets. Figure 2: Critical decisions when selecting a PDU or power strip 2 3 1 4

Chatsworth Products White Paper 4 1. Form Factor - rack size The first decision when selecting a PDU or powers strip is the form factor. There are two options: vertical and horizontal configuration (Figure 3). The vertical configuration attaches to brackets positioned alongside the mounting rails on the rack. The horizontal configuration uses 1U or 2U of rack-mount space. Ask if a vertical or horizontal (rack-mount) PDU is required. If the form factor is unknown, select a vertical PDU for a rack that has 42U or more of rack-mount space and is a minimum of 6 (2 m) in height and 23.6 (600 mm) in width. Select a horizontal (rack-mount) PDU for a rack with less than 42U of rack-mount space or if less than 6 (2 m) in height, including any wall-mount rack. Vertical and horizontal (rack-mount) form factor is standard on all CPI PDUs and power strips. Figure 3: Vertical PDUs and power strips are typically used in cabinets and racks that are 6 (2 m) high, 23.6 (600 mm) wide, and 42U or larger. Horizontal PDUs and power strips are used in wall-mount racks and cabinets.

Chatsworth Products White Paper 5 2. Input Plug - the branch circuit receptacle and available power The second decision when selecting a PDU or powers strip is the type of input plug. The input plug must match the branch circuit receptacle at the rack. Ask what type of input plug is required or what the power receptacle is at the rack to identify the matching plug (use Table 1 below). How many type of input plugs are there? There are many types of input plugs. There are several power systems globally and several branch circuits in each power system. Additionally, most nations have their own plug standards (plug designs), and there is also an international plug standard. For safety, plugs and matching receptacles are physically different (keyed) for each type of branch circuit connection to prevent accidental connection between incompatible devices. Most PDU and power strip manufacturers offer a mix of national and international plugs. Which input plugs are used most frequently? It depends on where your site is located. It will be the regional plug or a plug that meets the International standard. CPI offers PDUs and power strips with input plugs that meet the American National Standards Institute (ANSI)/National Electrical Manufacturers Association (NEMA) standards and the International Electrotechnical Commission (IEC) standards: ANSI/NEMA WD 6-2016 Wiring Devices Dimensional Specifications 1 IEC 60309-2012 Plug, Socket-Outlets and Couplers for Industrial Purposes 2 IEC 60320-2018 Appliance Couplers for Household and Similar General Purposes 3 The ANSI/NEMA standard is used primarily in North America. The IEC standard is used globally, including for some high Amperage connections in North America. The (Table 1) below illustrates the range of circuits and plugs supported by CPI PDUs and power strips. If the branch circuits are still being defined and only the total power requirement for the rack is known, then you can suggest some options using the capacity (kw) values in (Table 1). Be sure to explain that the branch circuit needs to be defined before the PDU or power strip can be selected so that the input plugs will match the branch circuit receptacles. You should never advise or attempt field modification of plugs. Region Typical Circuit Circuit Receptacle Input Plug Capacity (kw) North Single-Phase, 15 A, 120 VAC NEMA L5-15R NEMA L5-15P 1.4 America Single-Phase, 20 A, 120 VAC NEMA L5-20R NEMA L5-20P 1.9 Single-Phase, 20 A, 120 VAC IEC C19 IEC C20 1.9 Single-Phase, 30 A, 120 VAC NEMA L5-30R NEMA L5-30P 2.8 Single-Phase, 20 A, 120/208 VAC NEMA L14-20R NEMA L14-20P 3.3 Single-Phase, 20 A, 208 VAC NEMA L6-20R NEMA L6-20P 3.3 Single-Phase, 20 A, 208 VAC IEC C19 IEC C20 3.3 Single-Phase, 30 A, 120/208 VAC NEMA L14-30R NEMA L14-30R 4.9 Single-Phase, 30 A, 208 VAC NEMA L6-30R NEMA L6-30P 4.9 Three-Phase, 20 A, 120/208 VAC NEMA L21-20R NEMA L21-20P 5.7 Three-Phase, 20 A, 208 VAC NEMA L15-20R NEMA L15-20P 5.7 Three-Phase, 30 A, 120/208 VAC NEMA L21-30R NEMA L21-30P 8.6 Three-Phase, 30 A, 208 VAC NEMA L15-30R NEMA L15-30P 8.6 Three-Phase, 20 A, 240/415 VAC NEMA L22-20R NEMA L22-20P 11.4 Three-Phase, 50 A, 208 VAC CS8364C CS8365C 14.3 Three-Phase, 60 A, 208 VAC IEC 60A 3P+E 9h IEC 60A 3P+E 9h 17.3 Three-Phase, 30 A, 240/415 VAC NEMA L22-30R NEMA L22-30P 17.3 International Single-Phase, 16A, 230 VAC IEC C19 IEC C20 3.6 Single-Phase, 16A, 230 VAC IEC 16A 1P+N+E 6h IEC 16A 1P+N+E 6h 3.6 Single-Phase, 32A, 230 VAC IEC 32A 1P+N+E 6h IEC 32A 1P+N+E 6h 7.3 Three-Phase, 16A, 230 VAC IEC 16A 3P+N+E 9h IEC 16A 3P+N+E 9h 11.0 Three-Phase, 32A, 230 VAC IEC 32A 3P+N+E 9h IEC 32A 3P+N+E 9h 22.1 Table 1: Table of branch power circuits, receptacles, matching input plugs and maximum capacity. Note: International IEC plugs and receptacles (sockets) may also be designated by the number of poles and wires (#P#W) on the plug: IEC 1P+N+E are 2P3W, 3P+N+E are 4P5W, and 3P+E is 3P4W.

Chatsworth Products White Paper 6 What is the difference between single-phase and three-phase power? Commercial building power is delivered in three phases and may be distributed to the rack as three-phase or as single-phase power. A three-phase circuit delivers more power than a single-phase circuit (compare capacity in Table 1, Page 5). The impact on PDU or power strip selection is simply matching the correct input plug. 3. Outlets - connections for equipment The third decision when selecting a PDU or power strip is the number and type(s) of outlets required. There is an outlet (receptacle) to match each type of input plug, so you can choose a regional outlet or the international outlets. Also, whenever available, select outlets with a locking mechanism to ensure power cords remain plugged. Ask how many pieces of equipment, how many power connections for each piece of equipment and if any device requires other than a C13 or C19 outlet. C19 If the type of outlet required is unknown once you have determined the input plug, then select the PDU or power strip with the highest number of C13 and C19 outlets. Maximize the number of C19 outlets to support higher power blade servers or network chassis. C13 Selecting the best outlet If there is legacy equipment that requires a NEMA 5-20R outlet, then plan to consolidate it into a single cabinet and power with a PDU or power strip that includes a mix with NEMA 5-20R outlets. NEMA 5-20R There is an outlet to match every input plug. However, most pluggable rack-mount equipment powers between 100-250 VAC, under 16 Amperes and uses a power supply with an IEC 60320 C14 or C20 power input. So, you can connect most equipment to a PDU or power strip with jumpers using a mix of IEC 60320 C13 (matches C14) or C19 (matches C20) outlets. CPI, like many PDU and power strip manufacturers, uses a mix of these outlet styles on our intelligent econnect PDUs to deliver a more universal solution: IEC 60320, C13, capable of delivering 10 Amperes and 100-250 VAC nominal. The C13 is used to attach a C14 connection and will power most rack-mount equipment. IEC 60320, C19, capable of delivering 16 Amperes and 100-250 VAC nominal. The C19 is used to attach a C20 connection and will power larger blade server and switch chassis. Note that you can power a C14 connection with a C19 to C14 jumper. ANSI/NEMA WG-6, NEMA 5-20R, capable of delivering 20 Amperes and 100-120 VAC nominal. The NEMA 5-20R is used to attach a NEMA 5-20P plug and will power legacy 120 VAC equipment, LCD monitors, keyboard trays and basic appliances. Figure 4: A PDU with a mix of C13, C19 and NEMA 5-20R outlets. Note that the C19 and C13 outlets have locking mechanisms to secure plugs to the PDU to prevent accidental power disconnection. This approach also provides the flexibility to power a mix of equipment from a single PDU (Figure 4) allowing you to standardize on one or several PDUs instead of a different PDU for each region.

Chatsworth Products White Paper 7 There is also a wide range of power strips with the standard regional outlets (figure 5) to accept local plugs. NEMA 5-15R 125 VAC/15A NEMA 5-20R 120 VAC/20A IEC C13 UL: 120/208VAC/15A CE: 208VAC/10A IEC C19 UL: 120/208VAC/20A CE: 208VAC/16A BS1363 (UK) 230-250 VAC/13A Scxhuko DIM49440 230-250 VAC/16A 16A CEE7/7 Schuko Plug BS1363 Plug CEI23 Plug Figure 5: Examples of regional outlets. 4. Level of Functionality - monitoring and control The fourth decision when selecting a PDU or power strip is the level of functionality. Ask what level of monitoring is required for the application: no power monitoring, local power monitoring, remote power monitoring, remote outlet monitoring, remote outlet control or remote outlet monitoring and control. If the level of functionality is unknown, then select metered or monitored functionalities with any three-phase PDU to provide at minimum a local load-balancing capability and switched at remote locations to provide remote reboot capability. No Metering No metering provides no local or remote metering or monitoring capability. These units simply distribute power into the rack. This level of functionality is appropriate if the unit is attached to a rack-mount UPS or in data center applications where rack-level monitoring is not required. However, note that monitoring closer to the equipment provides more detail for identifying issues and optimizing power capacity utilization. No metering is standard on CPI Basic econnect PDUs and power strips. Local Metering Local metering includes at minimum an ammeter to measure and display input current (Figure 6). In multi-phase models, it is important to compare measurements and plug equipment to distribute power draw evenly across phases and breakers. Figure 6: Metered PDU with LED panel to show current draw on each phase (L1, L2, L3) Local metering is standard on CPI Metered, Monitored, Switched, Monitored Pro and Switched Pro econnect PDUs and power strips.

Chatsworth Products White Paper 8 Remote Monitoring Remote monitoring includes a network connection with a web interface for network monitoring (Figure 7). There are typically two models that measure power at the input and breaker(s) and optionally at each outlet. Input monitoring on three-phase units allows you to balance loads across the phases, which helps upstream in the power distribution system. Breaker monitoring prevents overloading of circuits on the PDU. Outlet measurements show power draw by individual equipment. Figure 7: Monitored Pro econnect PDU with network monitoring of power at the input, breakers and outlets Look for models that can measure: line input current, branch voltage (V), current (A), power factor, power (kw), and energy (kwh) with +/- 1 percent accuracy. The firmware should support PDU and outlet naming, upper and lower voltage and current alarms, logging of measured values on user-defined interval, the ability to group outlets to show a combined measurement and third-party Data Center Infrastructure Management (DCIM) software integration. Remote monitoring at the PDU level (rack-level) is standard on CPI Monitored, Switched, Monitored Pro and Switched Pro econnect PDUs. Remote monitoring at the outlet level (device-level) is standard on CPI Monitored Pro and Switched Pro econnect PDUs.

Chatsworth Products White Paper 9 Remote Control Remote control includes a network connection and web interface for controlling outlets (Figure 8). Power to each outlet can be turned on, off or cycled remotely. Turn power off on unused outlets to force a review of new equipment before deployment. Cycle power to remote equipment as part of a troubleshooting process. Note that outlets can be both monitored and controlled. Look for models that have an LED indicator next to the outlets to indicate on or off status and that can set a cycle time by outlet to prevent inrush currents or to sequence reboot processes. The firmware should support PDU and outlet naming, logging of power cycle events, the ability to group outlets to allow a single-click power cycle for dual- and multi-corded equipment and third-party DCIM software integration. Remote control at the outlet level (the device level) is standard on CPI Switched and Switched Pro econnect PDUs. Switched Pro econnect PDUs also monitor at the outlet level (the device level). Conclusion: finding the right product Once you have determined form factor, input plug, outlets and functionality, it is easy to select a PDU or power strip. CPI offers an easy-to-use, online tool, the CPI Power Selector www.selectapdu.com that will provide an exact part number and product specification based on your selections (Figure 9). Figure 8: The Switched econnect PDU with remote control outlets, blue LED indicating on, amber indicating off. Figure 9: The CPI Power Selector is an easy-to-use, online tool for identifying and comparing CPI PDUs and power strips. Filter by form factor, input plug, outlets and functionality.

Chatsworth Products White Paper 10 CPI PDU and Power Strip Functionality Quick Reference CPI offers all of the levels of functionality discussed in this white paper. CPI names the levels of econnect PDU functionality: Basic, Metered, Monitored, Switched, Monitored Pro, Switched Pro. The capabilities are identified in the table below (Table 2). Functionality Basic Power Distribution Inlet Metering Branch Circuit Metering Networking Outlet Metering Switched Outlets Secure Array Environmental Monitoring Access Control Basic - Simple, reliable power distribution to equipment in your cabinets. Select a Basic PDU when no power monitoring is required. P Metered - Includes local LED display for easy reading of input current across phases. Selected a Metered PDU when networking of PDUs is not an option. P P Monitored - Includes local and remote power monitoring for the PDU. Select a Monitored PDU when you want to monitor total power usage. Monitored Pro - Includes local and remote power monitoring for each outlet on the PDU. Select a Monitored Pro PDU when you need to remotely measure individual power used by each piece of equipment. Switched - Includes local and remote power monitoring for the PDU and individual outlet control. Select a Switched PDU if you need to remotely turn power on or off at each outlet. Switched Pro - Includes local and remote power monitoring for the PDU and each outlet on the PDU, as well as individual outlet control. Select a Switched Pro PDU to remotely measure and control power at each outlet. P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P P Table 2: Features available for each CPI PDU and power strip functionality level.

Chatsworth Products White Paper 11 Why Select a CPI PDU or Power Strip? CPI has more than 300 standard PDU and power strip models encompassing all functionality levels, form factors and electrical configurations. CPI also provides custom configurations in case standard configurations do not meet all your needs. CPI manufacturers a complete solution for the rack space. CPI can be your single source for PDU, rack, cable management, airflow management, environmental monitoring, access control and DCIM software. The complete solution is the CPI cabinet ecosystem. You can order a cabinet with PDUs and all accessories preinstalled or kitted to match your site requirements. The systems are fully compatible, easy to configure and operate. Monitoring at the rack level provides the data you need to optimize space, power and cooling utilization at your site. If you would like some help selecting a product or have a technical question, contact our Technical Support department techsupport@chatsworth.com To learn more about PDUs and power strips, download the companion white paper: Additional Considerations When Selecting Power Distribution Units and Power Strips https://www.chatsworth.com/white-papers References 1 National Electrical Manufacturers Association. ANSI/NEMA WD 6-2016 Wiring Devices Dimensional Specifications. Published 2016. https://www.nema.org/standards/pages/wiring-devices-dimensional-specifications.aspx 2 International Electrotechnical Commission. IEC 60309-1: 1999, 2005, 2012 Plugs, socket-outlets and couplers for industrial purposes Part 1: general requirements. Published 2012. https://webstore.iec.ch/publication/1318 2 International Electrotechnical Commission. IEC 60309-2: 1999, 2005, 2012 Plugs, socket-outlets and couplers for industrial purposes Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories. Published 2012. https://webstore.iec.ch/publication/1323 3 International Electrotechnical Commission. IEC 60320-1:2015, 2018 Appliance Couplers for household and similar general purpose Part 1: general requirements. Published 2018. https://webstore.iec.ch/publication/63846. Contributor David Knapp Product Marketing Manager David Knapp is a Product Marketing Manager at Chatsworth Products (CPI). He has more than 20 years of experience in the telecommunications industry as a product-application expert and technical communicator. He is currently focusing on data center, enterprise networking and power management solutions. While every effort has been made to ensure the accuracy of all information, CPI does not accept liability for any errors or omissions and reserves the right to change information and descriptions of listed services and products. 2019 Chatsworth Products, Inc. All rights reserved. Chatsworth Products, Clik-Nut, CPI, CPI Passive Cooling, econnect, Evolution, GlobalFrame, MegaFrame, Motive, OnTrac, QuadraRack, RMR, Saf-T-Grip, Secure Array, SeismicFrame, SlimFrame, TeraFrame and Velocity are federally registered trademarks of Chatsworth Products. CUBE-iT, EuroFrame and Simply Efficient are trademarks of Chatsworth Products. All other trademarks belong to their respective companies. 01/19 MKT-60020-706