Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Similar documents
RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MC 11 EB-2 Power supply cabinet with external bus, AC version

TRC-190 User s Manual

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

TRC-190 User s Manual

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

H704-42(H)(E), H704-42/1(H)(E)

Operating Instructions Güntner Master Panel GMP

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Installation Instructions

MINI MCR-SL-MUX-V8-FLK 16

PROFIBUS-DP/MODBUS RTU REPEATER

Installation Instructions

Installation Instructions

MINI MCR-SL-UI-2I(-SP)(-NC)

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Hardware Manual RM Display 2501 S01..S04

ASTAT XB/XBm Remote Operator

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Operating and Maintenance Instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SIMOCODE 3UF Motor Management and Control Devices

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

MINI MCR-SL-PT100-UI-200

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

QUINT-BUFFER/24DC/24DC/40

PTC/PT100 board 2.0 Option

1. Introduction. 2. Installation MODBUS INTERFACE

LVX Control Unit. Features:

SoundwebTM. Installation Guide

VersaMax IP Input Module

Hardware Manual ipc-i 320/PCI II Intelligent PC/CAN Interface

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

Adapter Kit - Remote QSI Electronics Installation Instructions

Installation Instructions

Manual Fiber Optic Interfaces

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

MINI MCR-SL-CVS NC

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

CANdoISO Module Datasheet

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

PXR11 PXR12. System controllers DESIGO PX

Manual Industry Interfaces

RXTH DUAL ROOM SENSOR / SWITCH

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Zone monitoring device TGÜ-BS 2.6 (Slave) for car parks

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

HEC. General Operating, Maintenance and Installation Manual

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Hardware Manual RM Display 2401

RXTP ROOM TEMPERATURE

PHOENIX CONTACT

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

Belimo Gateway MP to Modbus RTU - UK24MOD

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

RTU560 Connections and Settings DIN Rail RTU 560CIG10

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

P3-SCM. General Specifications

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Kvaser Linx J1587 User's Guide

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

USB I/O-CARD WITH 32 INPUTS

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

iswitch imotor Compact QR

ELSETA IOMOD 8DI8DO. User manual. Elseta 3/2017 V1.0

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

TF501, TF521 Terminal Bases

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

ACCESS 9340/9360 Meter Input/Output Module

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

DR 4500A Circular Chart Recorder Kit Instruction RS485 Modbus Communications Printed Circuit Board Kit (Part Number )

TRIO-DIODE/12-24DC/2X10/1X20

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

ICF-1150 Series Quick Installation Guide

SUBCON-PLUS-PROFIB...

RS485 MODBUS Module 8I8O

Expansion Module HZS 541-1S

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Transcription:

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de

Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections... 4 1.3 LED...5 1.4 Slide switch... 5 1.5 Electrical properties of... 6 1.6 Installation / Operating conditions... 6 1.7 Scope of delivery...7 1.8 Dimensions and weight... 7 2 Installation... 8 2.1 Requirements... 8 2.1.1 Handling...8 2.1.2 Hardware...8 2.2 Installation... 9 2.3 Fault/troubleshooting... 11 2.4 Modbus network - termination, earthing, shielding... 12 3 Index... 13 4 Picture index... 14 5 Table index... 15

Page 3 / 15 1 GCM MOD GMM EC.1 1.1 Functional description The GCM MOD GMM EC.1 module is used to connect the GMM EC control unit to a Modbus network. It facilitates reading out data as well as external control via an RS485 interface. The protocol used is Modbus RTU. The RS485 interface of the Modbus module has galvanic separation. The GCM MOD GMM EC.1 module can be used for all GMM EC variants. Both the information transmitted via the bus interface and the protocol used are described in detail in the current Modbus interface specification.

Page 4 / 15 1.2 Connections Connections and components for GCM MOD GMM EC.1 Label SV1 Description Male connector for connecting the Modbus adapter to the EC controller of the GMM EC X1 CH CL GND Terminal on the internal CAN bus for extensions such as GHMspray CAN high signal of the internal CAN interface CAN low signal of the internal CAN interface Ground reference potential of the internal CAN interface X2 A B C Terminal for connecting to the Modbus network (RS485 two-wire interface). This interface has galvanic separation. Signal A / data + of Modbus interface Signal B / data of Modbus interface Common / GND reference potential of the Modbus interface Connections for GCM MOD GMM EC

Page 5 / 15 1.3 LED LED name LED state Description D1 on flashing Module ready for operation, no Modbus communication Module ready for operation, active Modbus communication off Module not ready for operation (1) State of LED D1 (1) See Fault/troubleshooting, Page 11 1.4 Slide switch Number State Description S1 1 2 Control of EC controller off on off on Normal operation of EC controller (default) Reset EC controller Normal operation of EC controller (default) Boot mode of EC controller S2 Control of Modbus adapter 1 2 off on off on Normal operation of Modbus adapter (default) Reset Modbus adapter Normal operation of Modbus adapter (default) Boot mode of Modbus adapter 3 off Modbus termination inactive (2) on Modbus termination active (default) (2) DIP switch settings (2) Termination may be activated only on the first and last units on the Modbus network. All other units must have termination deactivated.

Page 6 / 15 1.5 Electrical properties of Min Type Max Unit Power supply 4.75 5.0 5.25 V Current consumption 110 200 ma Power consumption 0.55 1.1 W Modbus Termination (can be switched in) 120 Ω Transmission rate 1200 9600 115200 bit/s Galvanic separation 1,000 V (rms) Withstand voltage A/B -7 +12 V Electrical properties 1.6 Installation / Operating conditions The Modbus module is intended for installation in a GMM EC casing. Installation must only be performed by personnel with appropriate professional training. The shielding of bus lines must be earthed at one end only. Suitable shielding and routing measures must be taken to ensure that mains cables and motor cables do not cause any interference in signal and control lines. Bus cables must be connected via shielded cables. Recommended cables: Belden 9841, Lapp 2170203, Lapp 2170803, Helukabel 81910 Temperature in operation: Temperature for storage and transport -20 C ~ +70 C -20 C ~ +70 C, dry The GMM EC with Modbus adapter GCM MOD GMM EC.1 complies with the EMC standards: EN 61000-6-2 (Immunity for industrial environments) EN 61000-6-3 (Noise emission for residential use) IEC 61000-4-4/-5/-6/-11

Page 7 / 15 1.7 Scope of delivery GCM MOD GMM EC.1 module pre-assembled incl. fastening material Customised ribbon cable 165 mm Data sheet with installation instructions 1.8 Dimensions and weight GCM MOD GMM EC.1 All values in mm Weight: approx. 35g

Page 8 / 15 2 Installation 2.1 Requirements 2.1.1 Handling The GCM MOD GMM EC.1 reacts sensitively to electrostatic discharge. CAUTION Take appropriate precautionary measures when handling the module. An example of a precautionary measure is the wearing of an ESD wristband which is connected to an earthing point. Turn off the GMM EC power supply before beginning installation. 2.1.2 Hardware The GCM MOD GMM EC.1 can be installed on hardware version 3.2 or later of the EC controller board. It cannot be subsequently installed on earlier hardware versions. The hardware version can be found on the top and bottom of the circuit board. Since it is not always possible to identify the hardware version when the circuit board is installed, the easiest way of finding out a compatible version is by looking at the two mounting holes for the GCM, as shown in Image 2: EC/08 controller board and Image 3: EC/16 controller board. EC/08 controller board EC/16 controller board

Page 9 / 15 2.2 Installation 1) Disconnect the power supply to the GMM EC. 2) Remove the upper control unit from the GMM EC by loosening the screws as shown in Image 4: GMM EC/08 + GMM EC/16 and by disconnecting the connecting cable from the pin header of the lower controller PCB. GMM EC/08 + GMM EC/16 3) If not already done, insert the ribbon cable into the pin connector socket of the GCM. When doing so, ensure that the cable exits at the side to the left, as shown in Image 5: GCM MOD GMM EC with ribbon cable. GCM MOD GMM EC with ribbon cable 4) Now insert the free multipoint connector of the ribbon band into the corresponding pin connector socket of the controller circuit board. When using in the GMM EC/08, the ribbon cable is to be laid in a loop.

Page 10 / 15 GMM EC/08 cable loop 5) Place the GCM on the EC controller circuit board with the two spacer bolts screwed in place in the mounting holes of the controller circuit board and press it down slowly. The spacer bolts must snap into place in the controller circuit board. If the bolts are correctly snapped into place it is no longer possible to remove them. The two additional spacer bolts are used for mechanical stabilisation and merely lay on the controller circuit board. They are not screwed in place. The upper spacer bolt fixes the position of the GCM towards the support plate of the control unit. Check that the spacer bolts are correctly seated before continuing with the installation. 6) Check that the DIP switch is correctly set for normal operation. see graphic Connections, Page 4 and see table Slide switch, Page 5 Activate or deactivate the termination for the Modbus according to the position of the GMM EC on the Modbus network. Termination may be activated only on the first and last units on the Modbus network. All other units must have termination deactivated. See Modbus network - termination, earthing, shielding, Page 12 7) For mounting the upper control unit, first reconnect the connecting cable to the pin header of the controller PCB and then attach the support plate again using the screws from step 2. 8) Connect the shield of the Modbus cable to the corresponding subplate on the EC controller board. If you are using a GMM EC/16 with 16 fans, use the upper subplate to fit the shielding. see Image 4: GMM EC/08 + GMM EC/16, Page 9 Recommended cable types are listed under Installation / Operating conditions, Page 6. The standard connection for the shielding is on the lower subplate, onto which the shielding for the fans is also fitted. See Modbus network - termination, earthing, shielding, Page 12 9) Connect the signal lines of the Modbus cable to the terminals of terminal strip X2. see table Connections, Page 4 The Modbus interface is galvanically isolated from the GMM-EC. 10) The unit is now ready for operation. After switching on the GMM EC supply voltage, the operating state of the GCM MOD GMM EC.1 can be verified using the LED D1. see table LED, Page 5

Page 11 / 15 2.3 Fault/troubleshooting Fault status Cause/troubleshooting Fault with supply voltage Check mains voltage of GMM EC, check fuses, check that ribbon cable connector is correctly seated LED does not illuminate DIP switch "GCM Reset" and/or "GCM Firmware" active Put S2 switches 1 + 2 into the OFF position Fault with firmware Reimport firmware for GCM MOD GMM EC Control unit displays the following: "No power unit" or "Fault with bus" LED does not flash, even though the Modbus master is active DIP switch "ECC Reset" and/or "ECC Firmware" active Put S1 switches 1 + 2 into the OFF position Fault with signal connection Check connection of signals A and B Faulty configuration of Modbus address, baud rate or framing parameters Check setting of the Modbus interface parameters in the GMM EC control unit Fault/troubleshooting

Page 12 / 15 2.4 Modbus network - termination, earthing, shielding

Page 13 / 15 3 Index C Connections... 4 F Fault/troubleshooting... 11 H Handling... 8 I Installation... 8 L LED... 5 S Scope of delivery... 7 Slide switch... 5 T Troubleshooting... 11

Page 14 / 15 4 Picture index Image 1: Connections and components for GCM MOD GMM EC.1...4 Image 2: EC/08 controller board...8 Image 3: EC/16 controller board...8 Image 4: GMM EC/08 + GMM EC/16... 9 Image 5: GCM MOD GMM EC with ribbon cable... 9 Image 6: GMM EC/08 cable loop...10

Page 15 / 15 5 Table index Table 1: Connections for GCM MOD GMM EC...4 Table 2: State of LED D1...5 Table 3: DIP switch settings...5 Table 4: Electrical properties...6 Table 5: Fault/troubleshooting... 11